V2 CALYPSO Series, Calypso 400, Calypso 500 Manual
Add to my manuals
14 Pages
V2 CALYPSO Series is an irreversible electromechanical actuator for swing gates, designed for residential and small commercial use. It offers reliable and secure automation for gates weighing up to 500kg and a maximum leaf length of 2.5 meters. The CALYPSO Series is equipped with a powerful motor and robust gearbox, ensuring smooth and efficient operation. It features adjustable opening and closing speed, allowing for customization to suit specific requirements.
advertisement
IL 186
EDIZ. 10/09/2018
CALYPSO
I
ATTUATORE ELETTROMECCANICO
IRREVERSIBILE PER CANCELLI A
BATTENTE
GB
IRREVERSIBLE
ELECTROMECHANICAL
ACTUATOR FOR SWING GATES
F
OPERATEUR
ELECTROMECANIQUE
IRREVERSIBLE POUR PORTAILS
BATTANTS
E
OPERADOR ELECTROMECÁNICO
IRREVERSIBLE PARA CANCELAS
BATIENTES
D
NICHT UMKEHRBARER
ELEKTROMECHANISCHER
ANTRIEB FÜR FLÜGELTORE
NL
ELEKTROMECHANISCHE,
ONOMKEERBARE LINEAIRE
MOTOR VOOR HEKKEN MET
VLEUGELS
PL
ELEKTROMECHANICZNY
NIEODWRACALNY SIŁOWNIK DO
BRAM SKRZYDŁOWYCH
H
VISSZAFORDÍTHATATLAN
ELEKTRO-MECHANIKUS
MŰKÖDTETŐ LENGŐ KAPUKHOZ
P
ACTUADOR ELECTROMECÂNICO
IRREVERSÍVEL PARA PORTÕES DE
BATENTE
- 1 -
RU
НЕРЕВЕРСИВНЫЙ
ЭЛЕКТРОМЕХАНИЧЕСКИЙ
ПРИВОД ДЛЯ РАСПАШНЫХ
ВОРОТ
A
B
C
B
C
CALYPSO
A
400
819
762
1162
500
944
887
1387
600
1044
987
1644
ø13 mm
8,5 mm
59,5 mm
10 mm
ø12,5 mm
120 mm
IMPORTANT REMARKS
m
Prior to proceeding with installation, it is essential the instructions be read in full, since they contain important information regarding safety, installation, use and maintenance.
AUTOMATION MUST BE IMPLEMENTED IN COMPLIANCE
WITH THE EUROPEAN REGULATIONS IN FORCE:
EN 60204-1, EN 12445, EN 12453, EN 13241-1, EN 12635
• The installer must provide for a device (es. magnetotermical switch) ensuring the omnipolar sectioning of the equipment from the power supply. The standards require a separation of the contacts of at least 3 mm in each pole (EN 60335-1).
• The plastic case has an IP44 insulation; to connect flexible or rigid pipes, use pipefittings having the same insulation level.
• Installation requires mechanical and electrical skills, therefore it shall be carried out by qualified personnel only, who can issue the Compliance Certificate concerning the whole installation
(Machine Directive 2006/42/CEE, Annex IIA).
• Also the automation upstream electric system shall comply with the laws and rules in force and be carried out workmanlike.
• We recommend to make use of an emergency button, to be installed by the automation (connected to the control unit
STOP input) so that the gate may be immediately stopped in case of danger.
• For correct installation of the system, we recommend following the instructions issued by UNAC very carefully.
• This instruction manual is only for qualified technicians, who specialize in installations and automations.
• The contents of this instruction manual do not concern the end user.
• Every programming and/or every maintenance service should be done only by qualified technicians.
• Anything not expressly described in these instructions is prohibited; unforeseen uses may be a source of danger to people and property.
• Do not install the product in explosive environments and atmospheres: the presence of inflammable gases or fumes is a serious safety hazard.
• Do not make any modifications to any part of the automation device, or the accessories connected to it, unless described in this manual.
• Any other modifications will void the warranty on the product.
• The installation steps should be conducted so as to avoid rainy weather, which can expose electronic circuits to dangerous water seepage.
• All operations requiring the casing of the device to opened should be performed with the control unit disconnected from the electricity supply and with a warning notice displayed, for example: ”CAUTION, MAINTENANCE IN PROGRESS”.
• Avoid exposing the device close to sources of heat and flame.
• In the event of interventions on automatic or differential breakers or fuses, it is essential that faults be identified and resolved prior to resetting. In the case of faults that cannot be resolved using the information to be found in this manual, consult the V2 customer assistance service.
• V2 declines all responsibility for failure to comply with good construction practice standards in addition to structural deformation of the gate that might occur during use.
• V2 reserves the right to make modifications to the product without prior warning.
• Installation/maintenance personnel should wear individual protection devices (IPDs), such as overalls, safety helmets, boots and gloves.
- 7 -
• The ambient operating temperature should be that indicated in the technical characteristics table.
• The automation device should be shut down immediately in the event of any anomalous or hazardous situation; the fault or malfunction should be immediately reported to the person responsible.
• All safety and hazard warnings on the machinery and equipment should be complied with.
• Electromechanical actuators for gates are not intended to be used by people (including children) with diminished physical, sensory or mental capacity, or lacking in experience or knowledge, unless they are under supervision or have been instructed in use of the actuator by a person responsible for safety.
V2 has the right to modify the product without previous notice; it also declines any responsibility to damage or injury to people or things caused by improper use or wrong installation.
DISPOSAL OF THE PRODUCT
As for the installation operations, even at the end of this product’s life span, the dismantling operations must be carried out by qualified experts.
This product is made up of various types of materials: some can be recycled while others need to be disposed of. Find out about the recycling or disposal systems envisaged by your local regulations for this product category.
Important!
– Parts of the product could contain pollutants or hazardous substances which, if released into the environment, could cause harmful effects to the environment itself as well as to human health.
As indicated by the symbol opposite, throwing away this product as domestic waste is strictly forbidden. So dispose of it as differentiated waste, in accordance with your local regulations, or return the product to the retailer when you purchase a new equivalent product.
Important!
– the local applicable regulations may envisage heavy sanctions in the event of illegal disposal of this product.
TECHNICAL SERVICE
For any installation problem please contact our Customer Service at the number +39-0172.812411 operating Monday to Friday from 8:30 to 12:30 and from 14:00 to 18:00.
PRELIMINARY CHECKS AND IDENTIFICATION OF THE TYPE TO BE USED
The automation device should not be used until installation, as specified in “Testing and start-up”, has been performed.
It should be remembered that the device does not compensate for defects caused by improper installation, or poor maintenance, thus, prior to proceeding with installation, ensure that the structure is suitable and meets current standards and, if necessary, perform any structural modifications aimed at the implementation of safety gaps and the protection or segregation of all crushing, shearing and transit zones, and verify that:
• The gate is equipped with central and side stops.
• The gate has no friction points, either during closing or opening.
• The gate is well balanced, i.e. there is no tendency to move spontaneously when stopped in any position.
• The position identified for fixing the motor reducer allows easy and safe manual manoeuvring, compatible with the size of the motor reducer itself.
• The support on which the automation device will be fixed is solid and durable.
• The mains power supply to which the automation device is connected has a dedicated safety earthing system and differential breaker with tripping current less than or equal to 30 mA (the breaker gap distance should be greater than or equal to 3 mm).
Warning: The minimum safety level depends on the type of use; please refer to the following outline:
TYPE OF ACTIVATION
COMMANDS
GROUP 1
Informed people
(use in private area)
A
C or E
CLOSURE USE TYPE
GROUP 2
Informed people
(use in public area)
B
C or E
GROUP 3
Informed people
(unlimited use)
Not possible
C and D or E
Man-present command
Remote control and closure in view (e.g. infrared)
Remote control and closure not in view (e.g. radio)
Automatic control
(e.g. timed closure control)
C or E
C and D or E
C and D or E
C and D or E
C and D or E
C and D or E
GROUP 1 - Only a limited number of people are authorised for use, and closure is not in a public area. Examples of this type are gates inside business premises, where the sole users are employees, or a part of them who have been suitably informed.
GROUP 2 - Only a limited number of people are authorised for use, but in this case, closure is in a public area. An example of this may be a company gate that accesses onto a public street, and which is only used by employees.
GROUP 3 - Anyone can use the automated closure, which is thus located on public land. For example the access gate to a supermarket or an office, or a hospital.
PROTECTION A - Closure is activated by means of a control button with the person present, i.e. with maintained action.
PROTECTION B - With the person present, closure is activated by a command controlled by means of a key-switch or the like, in order to prevent use by unauthorised persons.
PROTECTION C - Restricts the force of the leaf of the door or gate. I.e., in the case of the gate striking an obstacle, the impact force must fall within a curve established by the regulations.
PROTECTION D - Devices, such as photocells, capable of detecting the presence of people or obstacles. They may be active on just one side or on both sides of the door or gate.
PROTECTION E - Sensitive devices, such as footboards or immaterial barriers, capable of detecting the presence of a person, and installed in such a way that the latter cannot be struck in any way by a moving leaf or panel. These devices should be active within the entire “danger zone” of the gate. The Machinery Directive defines “Danger Zone” as any zone surrounding and/or near machinery where the presence of an exposed person constitutes a risk to the health and safety of that person.
The risk analysis should take into consideration all danger zones for the automation device, which should be appropriately protected and marked.
In a clearly visible area, apply a sign with information identifying the motorised door or gate.
The installer should provide the user with all the information relating to automatic operation, emergency opening and maintenance of the motorised door or gate.
- 8 -
EU DECLARATION OF CONFORMITY
AND DECLARATION OF
INCORPORATION OF PARTLY
COMPLETED MACHINE
Declaration in accordance with Directives: 2014/35/UE (LVD);
2014/30/UE (EMC); 2006/42/CE (MD) ANNEX II, PART B
The manufacturer (*) V2 S.p.A., headquarters in Corso Principi di
Piemonte 65, 12035, Racconigi (CN), Italy
Under its sole responsibility hereby declares that: the partly completed machinery model(s):
CALYPSO400-230V (*), CALYPSO500-230V (*)
CALYPSO600-230V (*)
CALYPSO400-120V (*), CALYPSO500-120V (*)
CALYPSO600-120V (*)
CALYPSO400-24V (*), CALYPSO500-24V (*)
CALYPSO600-24V (*)
Description: electromechanical actuator for gates
• is intended to be installed on gates, to create a machine according to the provisions of the Directive 2006/42/EC.
The machinery must not be put into service until the final machinery into which it has to be incorporated has been declared in conformity with the provisions of the Directive
2006/42/EC and 89/106/CE.
• is compliant with the applicable essential safety requirements of the following Directives:
Machinery Directive 2006/42/EC (annex I, chapter 1)
Low Voltage Directive 2014/35/EU
Electromagnetic Compatibility Directive 2014/30/EU
Directive ROHS2 2011/65/CE
The relevant technical documentation is available at the national authorities’ request after justifiable request to:
V2 S.p.A., Corso Principi di Piemonte 65, 12035, Racconigi (CN),
Italia
The person empowered to draw up the declaration and to provide the technical documentation:
Antonio Livio Costamagna
Legal representative of V2 S.p.A.
Racconigi, il 01/06/2015
(*) made in extra EU Countries on behalf of V2 S.p.A.
TECHNICAL DATA
Max. leaf lenght
Max. leaf weight
Power supply
Idling current
Full load current
Electric power
Opening time of the leaf 0÷90°
Capacitor
Max travel
Operating speed
Maximum thrust
Working temperature
Protection
Working cycle
Motor weight m
Kg
CALYPSO
400-230V
2,5
400
CALYPSO
500-230V
3
500
CALYPSO
600-230V
4
500
CALYPSO
400-120V
2,5
400
CALYPSO
500-120V
3
500
CALYPSO
600-120V
4
500
CALYPSO
400-24V
2,5
300
Vac - Hz 230 - 50 230 - 50 230 - 50 120 - 60 120 - 60 120 - 60 24 Vdc
A
A
W
0,8
1,2
200
0,8
1,2
200
0,8
1,2
200
2
2,8
300
2
2,8
300
2
2,8
300
2
10
s 22 25 30 22 25 30 22
µF mm m/s
N
°C
IP
%
Kg
8
400
0,016
2300
44
30
6,5
8
500
0,016
2300
CALYPSO
500-24V
3
400
24 Vdc
2
10
-
27
-30 ÷ +50 -30 ÷ +50 -30 ÷ +50 -30 ÷ +50 -30 ÷ +50 -30 ÷ +50 -30 ÷ +50 -30 ÷ +50 -30 ÷ +50
44
30
6,8
8
600
0,016
2300
44
30
7,1
25
400
0,018
2300
44
30
6,5
25
500
0,018
2300
44
30
6,8
25
600
0,018
2300
44
30
7,1
-
400
-
2000
44
90
6,3
-
500
-
2000
44
90
6,6
8
600
-
2000
44
90
7,1
CALYPSO
600-24V
4
400
24 Vdc
2
10
-
35
- 9 -
INSTALLATION LAYOUT
6 5
A
4 2
C
1 D 1
3
COMPONENTS
4
5
6
1
2
3
Motor
Control unit
Transmitter
Receiving module
Photocells
Flashing light
LENGTH OF THE CABLE
Power supply (230V)
230V motor power supply
24V motor power supply
Photocells (TX)
Photocells (RX)
Key switch
Safety edges
Flashing light
Antenna (integrated into the flashing light)
ECO-LOGIC (accumulator unit)
ECO-LOGIC (solar panel)
ADDITIONAL ACCESSORIES
A
B
C
D
E
Key switch
Pillar photocells
Pillar-mounted digital radio switch
Safety edges
ECO-LOGIC system (only with CALYPSO-24V and CITY2+BC)
< 10 metres
3G x 1,5 mm 2
4G x 1,5 mm 2
2G x 1,5 mm 2
2 x 0,5 mm 2
4 x 0,5 mm 2
2 x 0,5 mm 2
2 x 0,5 mm 2
2 x 1,5 mm 2
RG174
2 x 1,5 mm 2
2 x 1 mm 2 from 10 to 20 metres
3G x 1,5 mm 2
4G x 1,5 mm 2
2G x 1,5 mm 2
2 x 0,5 mm 2
4 x 0,5 mm 2
2 x 0,5 mm 2
-
2 x 0,5 mm 2
2 x 1,5 mm 2
-
RG174 from 20 to 30 metres
3G x 2,5 mm 2
4G x 2,5 mm 2
2G x 2,5 mm 2
2 x 0,5 mm 2
4 x 0,5 mm 2
2 x 0,5 mm 2
-
2 x 0,5 mm 2
2 x 1,5 mm 2
-
RG174
- 10 -
INSTALLATION MEASURES
To carry out a proper installation of the operator parts as well as to ensure the best automation performance, the measurement levels shown in the following table shall be complied with. Change the gate structure to adapt it to one of the cases in the table, if necessary.
• For the installations OPENING TOWARDS THE INSIDE, refer to the table at page 62-63
• For the installations OPENING TOWARDS THE OUTSIDE, refer to the table at page 64-65 m
WARNING: In the case of leaf longer than 2 metres, an electric lock must be fitted to ensure an efficent closing
ACTUATOR FIXING
Choose measures referring to the table you can find in the previous page, mark them on the pillars and continue as follows:
• Fix the clamps to the pillar and to the gate soldering directly; if the material does not allow it, it is necessary to solder the clamps to plates to be fixed to the gate and the pillars by screws.
• Close the swing.
• Unlock the actuators.
• Position CALYPSO on the brackets and fix the pins no. 1 and no. 2 with seeger (see the picture).
• Open and close the swings repeatedly manually to verify the absence of frictions between gate and ground.
m
WARNING: in order to avoid damage to the actuator, please adhere to the following conditions:
• The brackets must be installed at the same height.
• In case of gate completely closed the maximum stroke of arm
A should not exceed:
456 mm (CALYPSO400)
556 mm (CALYPSO500)
625 mm (CALYPSO600)
• The minimum stroke of arm B must be more than 56 mm (in case of gate completely open).
- 11 -
A
ELECTRICAL CONNECTIONS
230V / 120V 24V
3
4
1
2
230V
YELLOW - GREEN
GREY
BLACK
BROWN
1
2
24V
BLACK
RED
120V
GREEN
WHITE
BLACK
RED
FUNCTION
CLOSING
OPENING
FUNCTION
GND
COMMON
CLOSING
OPENING
EMERGENCY RELEASE
In case of a blackout, the gate can be operated directly from the motor. Insert the key supplied in the lock, perform 1/2 of a turn.
To restore the automation, simply rotate the key in closed position and insert the provided plastic cover onto the lock.
m
WARNING: always remember to connect the earth according to current standards (EN 60335-1, EN 60204-1).
Avoid tension in the cable during open and close operations.
- 12 -
- 61 -
C F
γ
CALYPSO 400
g max
90°
B [mm]
130
150
170
190
200
210
250
C [mm]
130
140
150
150
150
140
120
F
[mm]
1010
1000
990
980
980
980
1010 g max
100° g max
110°
B [mm]
130
150
170
190
210
C [mm]
170
180
180
170
140
B [mm]
130
150
160
C [mm]
190
180
170
F
[mm]
970
960
960
970
990
F
[mm]
950
960
970
- 62 -
CALYPSO 500
g max
90°
B [mm]
130
150
170
190
210
230
250
270
290
C [mm]
170
180
180
190
190
190
180
190
170
F
[mm]
1200
1190
1190
1180
1170
1170
1170
1170
1180 g max
100° g max
110°
B [mm]
130
150
170
200
210
230
250
270
280
C [mm]
160
170
170
180
170
190
180
160
160
B [mm]
130
150
170
190
210
220
C [mm]
170
180
180
190
200
200
F
[mm]
1200
1190
1190
1180
1170
1170
F
[mm]
1210
1200
1200
1190
1190
1170
1180
1200
1200
CALYPSO 600
g max
90°
B [mm]
295
315
335 g max
100°
B [mm]
175
195
215
235
255
275
C [mm]
280
295
265
C [mm]
190
200
220
235
255
270
F [mm]
1290
1300
1310
F [mm]
1390
1370
1360
1350
1330
1300
- 63 g max
110°
B [mm]
195
215
235
255
C [mm]
200
220
235
250
F [mm]
1370
1360
1350
1335
C
γ
- 64 -
CALYPSO 400
g max
80°
85°
90°
95°
100°
110°
B [mm]
110 ÷ 130
110 ÷ 130
110 ÷ 130
110 ÷ 130
110 ÷ 130
110 ÷ 130
C [mm]
90
100
110
120
130
140
F [mm]
949
967
986
1006
1027
1057
CALYPSO 500
g max
80°
85°
90°
95°
100°
110°
B [mm]
130
130
130
130
130
130
C [mm]
100
110
120
130
140
150
F [mm]
995
1005
1015
1025
1035
1045
CALYPSO 600
g max
100°
110°
B [mm]
200
220
130
140
160
180
C [mm]
200
220
130
140
160
180
F [mm]
1340
1320
1380
1380
1380
1360
- 65 -
V2 S.p.A.
Corso Principi di Piemonte 65/67
12035 RACCONIGI CN (ITALY)
Tel. +39 0172 812411 - Fax +39 0172 84050 [email protected]
www.v2home.com
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Key Features
- Irreversible design for enhanced security
- Suitable for both residential and commercial applications
- Easy to install and maintain
- Complies with European safety regulations
- Manual release mechanism for emergency access
- Adjustable opening and closing speed
- Built-in obstacle detection for added safety