STI STI-SA5000-G/SS2105XT-EN Stopper® Station Installation Sheet

Add to My manuals
2 Pages

advertisement

STI STI-SA5000-G/SS2105XT-EN StopperĀ® Station Installation Sheet | Manualzz

TER

Y

LO

W B

AT

LED

S1

ON

OFF

1 Siren

Volume ouch LED

Don’t T

ON

LOW

BA

T

OFF

1

2 3

4

Fast

V1.3_x1

5500

Slow

S2

Don’t T ouch LED

FLASH RA

TE ADJUS

TMENT

2020_V1.6

FAST

SLOW

ON

ON DIP

OFF

1

LOW

BAT

1 2 3 4

2 3 4

STROBE

FLASH RATE

ADJUSTMENT

FAST

VR1

SLOW

ON

S1

OFF

1

LOW

BAT

2 3 4

STROBE

VOL SIREN

ON

1 2 3 4 5 6

OFF

S2

LOW BATTERY LED

VOL

ON

SIREN

DIP

ON

1 2 3 4 5 6

1 2 3 4 5 6

OFF

DETAILS S1 DETAILS S2

2306 Airport Road

Waterford • Michigan • 48327-1209

Phone: 248-673-9898 • Fax: 248-673-1246

E-mail: [email protected] • Web: www.sti-usa.com

Taylor House • 34 Sherwood Road • Bromsgrove

Worcestershire • B60 3DR • England

Tel: +44 (0)1527 520 999 • Fax: +44 (0)1527 501 999

E-mail: [email protected] • Web: www.sti-emea.com

PCB SCREWS

9 VDC BATTERY (NOT INCLUDED)

9 VDC BATTERY CONNECTOR

CIRCUIT BOARD

REFLECTORS

LENS

#6 x 2 1/2 in. SCREW

(2) PROVIDED

LENS

O-RING (2) PROVIDED

DRILL 3/16 DIA. HOLES

1 1/4 in. DEEP WHEN USING ANCHORS

DRILL 7/64 DIA. HOLES 1 1/4 in. DEEP

WHEN ANCHORS ARE NOT USED

#8-10 WALL ANCHOR (2) PROVIDED

ELECTRONIC BASE

PCB SCREWS

9 VDC BATTERY (NOT INCLUDED)

9 VDC BATTERY CONNECTOR

CIRCUIT BOARD

REFLECTORS

SPECIFICATION

Input Standby

9VDC < 14µA

12VDC < 180µA

24VDC < 170µA

Operating

0.95A

0.96A

0.49A

Operating Temperature

-4°F to 140°F (-20°C to 60°C)

LOW B

ATTER

LED

Y

S1

3.73 in.

(94.6 mm)

Strobe S2

Fast

Slow

5500 V1.3_x1

Don’ t Touch LED

FLA

SH RA

TE ADJUS

TMENT

3.73 in.

(94.6 mm)

3.87 in.

( 98.2 mm)

LENS

LO

W B

AT

TER

LED

Y

S1

OFF

1 Siren

Volume ouch LED Don’t T

OFF

ON

BA

LOW

S2

Slow

Don’t T ouch LED

FLASH RA

TE ADJUS

TMENT

#6 x 2 1/2 in. SCREW

(2) PROVIDED

LENS

O-RING (2) PROVIDED

DRILL 3/16 DIA. HOLES

1 1/4 in. DEEP WHEN USING ANCHORS

DRILL 7/64 DIA. HOLES 1 1/4 in. DEEP

WHEN ANCHORS ARE NOT USED

#8-10 WALL ANCHOR (2) PROVIDED

ELECTRONIC BASE

LO

W B

AT

TER

Y

LED

2020_V1.6

#6 x 2 1/2 in. SCREW

LENS

(2) PR

OVIDED

BATTERY INSTALLATION/REPLACEMENT

1. Unscrew lens to remove.

LENS

2. Loosen PCB screws (do not remove).

CIR

REFLE

CUIT B

Y (NO

Y C

ONNE

T INCL

CTOR

UDED)

PCB SCREWS 3. Gently rotate PCB without touching LED’s and

without damaging the reflectors.

.94 in.

(23.8 mm)

4. Connect battery and slide under retainer.

5. Re-install PCB and tighten screws.

DRILL 3/16 DIA

NOTES

ONIC B

WHEN ANCHORS ARE NO

ASE

#8-10 W

ALL ANCHOR (2) PR

. HOLES

T USED 1. Internal battery will provide backup power if loss of external power.

2. If no internal battery is used, remove all power and move S2-1 to

“OFF” position (see detail S2).

.94 in.

(23.8 mm)

FAST

SLOW

ON

ON DIP

OFF

1

1

LOW

2 3 4

2 3 4

STROBE

FLASH RATE

ADJUSTMENT

FAST

VR1

SLOW

S1

ON

OFF

1

LOW

2 3 4

STROBE

VOL

1 2 3

SIREN

4 5 6

ON

OFF

S2

LOW BATTERY LED

VOL

ON

SIREN

DIP

ON

1 2 3 4 5 6

1 2 3 4 5 6

OFF

DETAILS S1 DETAILS S2

LOW BATTERY OPERATON

Replace battery when low battery condition occurs,

Low battery LED flashes 1x per 1 minute and sounder beeps 1x per 3 minutes

1.02 in.

(26.0 mm)

2.83 in.

(71.8 mm)

1.02 in.

(26.0 mm)

2.83 in.

(71.8 mm)

1 2 3 4

1 ON

0 OFF

2020_V1.6

S2 - LOW BAT. NOTIFICATION/STROBE CONTROL

FAST

1 2 3 4 FUNCTION

FLA

ADJUS

*

1

0

OFF

LOW

1

ON

1

LOW BATTERY NOTIFICATION ON

2

3

2 3

STR

OBE

4

4

DIP

LOW BATTERY NOTIFICATION OFF

ON

FAST

VR1

SLO

W

VO

L

DETAILS S1

S1

1

LOW

2 3

4

OBE

VO

1

2 3

4 5

6

* 0 0 0 OFF CONTINUOUS “ON”

OFF

ON

1

ON

LOW B

ATTER

Y LED

S2

S2

2 3

4

4

5

6

DIP

0 0 1

2

DOUBLE LED ROTATION

5 6

OFF

0 1 0 3 FLASH - DELAY - 3 FLASH

DETAILS S2

0 1 1 SINGLE LED ROTATION (FAST)

1 0 0 FLASHING

1 0 1 INTENSITY RAMPING UP & DOWN

1 1 0 SINGLE LED ROTATION (SLOW)

1 1 1 RIGHT/LEFT ROTATION

*Default Settings

DETAIL S1

See pg. 2

S1

ON

OFF

1 Siren

Volume ouch LED

Don’t T

ON

BA

LOW

T

OFF

1

Strobe Fast

V1.3_x1

5500

Slow

S2

Don’t T ouch LED

FLASH RA

TE ADJUS

TMENT

DETAIL S2

WARNING: This product can expose you to chemicals including Dichloromethane, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the

State of California to cause birth defects or other reproductive harm. For more information go to

www.P65Warnings.ca.gov.

Three year warranty or a one year limited warranty (from date of purchase) on most products.

See website for details. Electronic warranty form at www.sti-usa.com/wc14 .

INSTALLATION OF STI-SA5500 SELECT ALERT SIREN/STROBE

All specifications and information shown were current as of publication and are subject to change without notice.

SA5500IS OCT2018

3.87 in.

( 98.2 mm)

2020_V1.6

FAST

SLOW

ON

ON DIP

OFF

1

LOW

BAT

1 2 3 4

2 3 4

STROBE

FLASH RATE

ADJUSTMENT

FAST

VR1

SLOW

ON

S1

OFF

1

LOW

BAT

2 3 4

STROBE

VOL SIREN

1 2 3 4 5 6

ON

OFF

S2

LOW BATTERY LED

VOL

ON

SIREN

DIP

ON

1 2 3 4 5 6

1 2 3 4 5 6

OFF

DETAILS S1 DETAILS S2

PCB SCREWS

9 VDC BATTERY (NOT INCLUDED)

9 VDC BATTERY CONNECTOR

CIRCUIT BOARD

REFLECTORS

LENS

#6 x 2 1/2 in. SCREW

(2) PROVIDED

LENS

O-RING (2) PROVIDED

DRILL 3/16 DIA. HOLES

1 1/4 in. DEEP WHEN USING ANCHORS

DRILL 7/64 DIA. HOLES 1 1/4 in. DEEP

WHEN ANCHORS ARE NOT USED

#8-10 WALL ANCHOR (2) PROVIDED

ELECTRONIC BASE

2306 Airport Road

Waterford • Michigan • 48327-1209

Phone: 248-673-9898 • Fax: 248-673-1246

E-mail: [email protected] • Web: www.sti-usa.com

Taylor House • 34 Sherwood Road • Bromsgrove

Worcestershire • B60 3DR • England

Tel: +44 (0)1527 520 999 • Fax: +44 (0)1527 501 999

E-mail: [email protected] • Web: www.sti-emea.com

SIREN

STROBE

TRIGGER

(NOT PROVIDED)

Control with Power Supply

Not supervised

- Alarm on close

- Cannot use battery turn off Low Battery Detect

STROBE & SIREN

RED (+)

BLK (-)

9VDC

YEL BLU

Power Supply Plus Battery

- Supervised trigger

- Alarm on open trigger

- Low battery alert

(Turn off if battery not used)

STROBE & SIREN

RED (+)

BLK (-)

9VDC

YEL BLU

+

-

+

-

TRIGGER

(NOT PROVIDED)

TRIGGER

(NOT PROVIDED)

+

-

STROBE ONLY

RED (+)

BLK (-)

9VDC

YEL BLU

TRIGGER

(NOT PROVIDED)

+

-

SIREN ONLY

RED (+)

BLK (-)

9VDC

YEL BLU

+

-

+

-

STROBE ONLY

RED (+)

BLK (-)

9VDC

YEL BLU

SIREN ONLY

RED (+)

BLK (-)

9VDC

YEL BLU

TRIGGER

(NOT PROVIDED)

TRIGGER

(NOT PROVIDED)

Battery Only

- Supervised trigger

- Alarm on open

trigger

- Low battery alert

STROBE & SIREN

RED (+)

BLK (-)

9VDC

YEL BLU

TRIGGER

(NOT PROVIDED)

STROBE ONLY

RED (+)

BLK (-)

9VDC

YEL BLU

TRIGGER

(NOT PROVIDED)

SIREN ONLY

RED (+)

BLK (-)

9VDC

YEL BLU

TRIGGER

(NOT PROVIDED)

S1 ALARM TONES

1 2 3 4 5 FUNCTION

* 1 1 1 1 1 1800Hz - 3300Hz @ 150ms

O 1 1 1 1 500Hz - 1200Hz, 0.5s/ 0.5s OFF x 3/1.5s OFF (AS1670 EVACUATION)

1 O 1 1 1 520Hz, 0.5s / 0.5s OFF x 3/1.5s OFF (FIRE)

O O 1 1 1 1200Hz - 500Hz @ 1Hz (DIN 33 404)

1 1 O 1 1 500Hz - 1200Hz, 3.75s ON / 0.25s OFF (AS2220)

O 1 O 1 1 550Hz/440Hz @ 0.5 Hz

1 O O 1 1 970Hz, 0.5s/ 630Hz, 0.5s

O O O 1 1 800Hz / 1000Hz 0.5s each (1Hz)

1 1 1 O 1 1500Hz - 2700Hz @ 3Hz

O 1 1 O 1 800Hz / 970Hz @2Hz

1 O 1 O 1 800Hz, 0.25s ON/ 1s OFF

O O 1 O 1 2400Hz - 2900Hz @ 9 Hz

1 1 O O 1 750Hz

O 1 O O 1 970Hz

1 O O O 1 970Hz, 1s OFF/1s ON

O O O O 1 500Hz - 1200Hz, 3.5s ON/ 0.5s OFF (NEN 2575:2000 DUTCH SLOW WHOOP)

1 1 1 1 O 800Hz - 970Hz @1Hz

O 1 1 1 O 1000-2500Hz, 0.5s/ 0.5s OFF x 3/1.5s OFF (AS1670 EVACUATION)

1 O 1 1 O 2850Hz, 0.5s ON/0.5s OFF x 3/1.5s OFF (ISO 8201)

O O 1 1 O 660Hz 1.8s ON/1.8s OFF

1 1 O 1 O 500Hz - 1200Hz @ 0.33Hz

O 1 O 1 O 250Hz - 1200Hz @ 12Hz

1 O O 1 O 2400Hz

O O O 1 O 800Hz - 970Hz @ 9Hz

1 1 1 O O 510Hz, 0.25s/ 610Hz, 0.25s

O 1 1 O O 550Hz, 0.7s/1000Hz, 0.33s

1 O 1 O O 660Hz 0.15s ON/0.15s OFF

O O 1 O O 800Hz - 970Hz @ 3Hz

1 1 O O O 420Hz 0.625s ON/0.625s OFF (AUSTRALIA AS1670 ALERT TONE)

O 1 O O O 554Hz, 0.1s/440Hz, 0.4s (AFNOR NF S 32 001)

1 O O O O 970Hz, 0.5s ON/0.5s OFF x 3/1.5s OFF (ISO 8201)

O O O O O 2400Hz - 2900Hz @ 3 Hz

S1 VOLUME

6 FUNCTION

* 1 High

0 Low volume

* Default Settings

1 2 3 4 5 6

1 ON

0 OFF

INSTALLATION OF STI-SA5500 SELECT ALERT SIREN/STROBE

All specifications and information shown were current as of publication and are subject to change without notice.

SA5500IS OCT2018

advertisement

Related manuals

advertisement