Xanboo XWT380 Quick Manual


Add to my manuals
7 Pages

advertisement

Xanboo XWT380 Quick Manual | Manualzz

THERMOSTAT

v1.0

PRODUCT DESCRIPTION ///

The XWT380 Thermostat is an innovative system designed to work with a home gateway enabling remote access and operation of your HVAC system. The XWT380 Thermostat offers state of the art performance and professional level reliability at cost effective prices. The fully optimized

418 MHz radio subsystem offers optimal range coverage allowing the Thermostat to be placed virtually anywhere.

PACKAGE CONTENTS ///

(1) Thermostat Base Unit

(1) Thermostat Display Unit

(1) 24 VAC Power Supply

(1) Wall Mounting Kit

(1) Installation Guide

MODE

THERMOSTAT BASE UNIT THERMOSTAT DISPLAY UNIT WALL MOUNTING KIT 24 VAC POWER SUPPLY

INSTALLATION ///

The system is comprised of the Thermostat display and user interface which replaces your old

Thermostat , and the base unit which should be installed adjacent to the HVAC System.

This installation must be performed by a qualified HVAC engineer. Be sure to read the complete system installation and operational manual.

The installer should ensure that all local wiring regulations and good practice are adhered to.

WALL MOUNTING THE THERMOSTAT DISPLAY UNIT ///

INSTALLATION

Before installing this unit:

1. Read all of the installation instructions carefully.

2. Read the User’s Manual carefully.

3. Ensure that this product is suitable for your application.

4. Ensure that wiring complies with all codes and ordinances.

5. Disconnect power to the control transformer of the HVAC to prevent electrical shock and damage to equipment.

LOCATION

XWT380 Thermostat display unit is designed to replace your old thermostat.

However, in order to ensure accurate and reliable operation, please check that the following criteria are met:

1. Ensure that the Thermostat is mounted between 5 and 5.5 ft above the floor level and is at least 2 feet away from an outdoor wall.

2. Ensure that the Thermostat is located in an area where there is adequate air circulation.

3. Ensure that the Thermostat display is not mounted in an area in direct sunlight, or in the path of heat generated by nearby appliances.

4. Ensure that it is not mounted on an outdoor wall, near a fireplace, or in the path of any air ducts.

REMOVING THE OLD THERMOSTAT

1. Disconnect the power to the control transformer.

2. Remove the cover to the existing Thermostat .

3. Disconnect the wires going to each terminal on the Thermostat .

4. Remove the existing plate or base from the wall if applicable.

I 2

INSTALLING THE DISPLAY UNIT

1. Press the small tab on the bottom center of the display unit with a small screwdriver and separate the front from the base.

2. Mount the base part on the wall, using suitable screws for the mounting surface.

Ensure the arrow points up.

SMALL TAB

BACK OF DISPLAY UNIT

3. Connect any two wires to the display unit’s terminal block situated on the back. It does not matter which color goes to which screw terminal.

6. Engage the upper tabs of the display unit with the counterparts on the base and press the bottom gently in until you feel it click into place. Do not use excessive force. Ensure you do not have excessive wire looped inside the enclosure.

NOTE: Be sure that the Thermostat temperature sensor has not been damaged during installation.

BASE UNIT INSTALLATION ///

CAUTION

This installation must be performed by a qualified HVAC engineer. Be sure to read the complete system installation and operational manual before you begin this installation.

IF WORKING WITH GAS CENTRAL HEATING UNIT ENSURE THE GAS VALVE IS SHUT OFF.

BE SURE TO DISCONNECT THE POWER TO THE CONTROL TRANSFORMER

Do not short gas valve, fan, heat relay, or cool relay. This may damage the Base unit.

DO NOT ATTEMPT TO HOOK UP TO LIVE CIRCUITS

An accidental connection to a component on the circuit board could cause damage to the Base unit and may be dangerous.

INSTALL THE BASE UNIT AT POINT NEAR THE HVAC UNIT AND CONVENIENT FOR ACCESS

Please also ensure that you mount the unit in a position that gives you easy access to the old thermostat wiring going to the HVAC’s control system.

1. Mount the unit vertically about on a wall as high as convenient (5.5 to 6 ft).

2. Remove the front cover by removing four (4) small screws on each side of the base unit.

SCREW TERMINALS

FRONT OF DISPLAY UNIT (REAR VIEW)

4. Make a note of the colors of these two wires as you will need to connect the same two wires to the base unit at the other end.

5. Upon completion of wiring the thermostat, push all excess wiring into the hole in the wall.

If there is a large hole in the wall, plug the hole with suitable filler or foam to ensure an accurate temperature reading by the Thermostat display unit.

3

HEAT COOL FAN

BASE UNIT INTERNALS FOR INSTALLATION

DISCOVERY BUTTON

RESET BUTTON

TERMINAL BLOCKS

4

3. Place the cover in a safe place and take care not to damage the plastic light pipe assembly mounted inside the cover.

4. Locate the cables that connected the old thermostat to the HVAC unit.

5. Ensure you make a note of the color/label relationship and remove the wires from the

HVAC control panel.

6. Now locate the same two wires the colors which you chose to connect the Thermostat display unit

(refer to your notes mentioned in the display unit installation instruction).

7. Using bottom right grommet entry connect the same two wires to the terminals marked “Com Link”.

Again, either color to either screw terminal.

NOTE: In order to maintain a good dust and bug seal pierce the grommets just enough to pull your wires through. Do not remove grommet. Ensure that all wires and their insulation are in good condition.

Replace any wire that shows sign of aging and feels brittle to the touch.

POWER CONNECTION ///

USING 24V AC FROM THE HVAC UNIT

If you can get easy access to the HVAC unit’s transformer you may use this to power the base unit.

However please check the following before doing so:

1. That the transformer rating is not exceeded when you add the display load (approx 200mA).

2. That the transformer is not switched via other circuits and has a permanent primary feed from the power line.

3. That the voltage does not exceed 27V AC.

NOTE: If in doubt please use the power adapter supplied with the Thermostat Kit. To do this, simply route the power wire through the lower left grommet into the housing and plug in the power jack.

CONNECTION TO HVAC UNIT ///

The following three diagrams cover heating only, cooling only, and heating/cooling combination

HVAC units. The notations used refer to most common notations used in HVAC wiring in the US.

The installer must verify that these notations do indeed adhere to the following:

“W” refers to the connection to the heat relay

“Y” refers to the connection to the cooling relay

“G” refers to the connection to the fan relay.

“R” refers to the connection to the 24V AC transformer.

“COMMON” refers to the connection between the other terminal of the transformer and all HVAC system relays.

5

COM LINK

TO DISPLAY UNIT

NO COM NC

W

(HEAT RELAY)

SINGLE STAGE HEATING/COOLING

NO

LINK

COM NC

Y

(COOL RELAY)

NO COM NC

LINK

G

(FAN RELAY)

R

24V AC

TRANSFORMER

24V AC POWER

JACK

COM LINK NO COM NC NO COM NC

LINK

TO DISPLAY UNIT

W

(HEAT RELAY)

SINGLE STAGE HEATING ONLY

NO COM NC

G

(FAN RELAY)

R

24V AC

TRANSFORMER

24V AC

POWER

JACK

COM LINK NO COM NC NO

LINK

COM NC

Y

(COOL RELAY)

TO DISPLAY UNIT

SINGLE STAGE COOLING ONLY

NO COM NC

LINK

G

(FAN RELAY)

R

24V AC

TRANSFORMER

24V AC POWER

JACK

1. Double check all your connections and ensure that the installation is neat and all connections are secure.

2. You are now ready to perform the discovery and final set up procedure covered in the main system manual.

3. Leave the cover of the base unit off until the whole system is operational.

4. Upon completion of the set up, replace the front cover and ensure that the light pipe assembly on the inside of the cover is not damaged or detached.

6

CONNECTING TO THE GATEWAY ///

DISCOVERING NEW DEVICES

In order for the Gateway to control devices such as cameras, thermostats and switches, each device must be registered with the Gateway. The Gateway establishes a “secure wireless network” between itself and all discovered devices. The Gateway can only control devices that it has discovered.

New devices can be discovered at any time.

In order for the Gateway and its associated devices to be used, it must be configured first and the devices it controls must be discovered. All configuration and discovery is performed through the Gateway local administration pages. To get to these pages you must log on to the Gateway using your browser. Please refer to your User Manual for Gateway configuration information.

Once configured, a setup wizard will be presented.

SETUP WIZARD - DEVICE DISCOVERY START PAGE

When you get to Step #4 of the setup wizard, press the discovery button on the devices you wish to discover at this time. Click the ‘NEXT’ button when you have completed discovering your devices.

NOTE: This page will automatically refresh every 15 seconds to display newly discovered devices.

It will also automatically stop discovering devices after 15 minutes. You will be able to discover devices at a later time if you choose to do so.

SETUP WIZARD - DEVICE DISCOVERY DEVICE SETUP PAGE

7

OPERATIONAL MODES ///

OFF

The Heating and Cooling systems are both off and do not respond to any changes in temperature settings.

HEAT

The Heating system activates to maintain desired heating setting. The Heating system will be turned on at one degree Fahrenheit (approximately 5ºC) below the set point and will turn off at the set point.

COOL

The Cooling system activates to maintain desired cooling setting. The Cooling system will be turned on at one degree Fahrenheit (approximately 5ºC) above the set point and will turn off at the set point.

AUTO

The Thermostat will automatically switch between heat and cool modes to maintain the desired heating and cooling temperature settings. To ensure that the heating and air conditioning systems are not activated simultaneously, the system has a built-in offset. This offset maintains a minimum of three degrees Fahrenheit or Celsius between the desired heat and cool temperatures. If you try to change one temperature set point within three degrees of the other temperature set point, the

Thermostat will automatically adjust the other set point to ensure the offset is maintained.

For example, if you have the heat set to a desired temperature of 69ºF and you attempt to set the desired cooling temperature to 71ºF, the desired heating temperature will automatically decrease to

68ºF to maintain the 3ºF difference.

The AUTO mode automatically turns the Heating or AC on, based on the temperature ranges you entered for Cool and Heat. However, the first time the Thermostat changes the operating mode from heat to cool or from cool to heat, the temperature must rise two degrees above the set point for the change to occur. This keeps your HVAC system from overshooting and constantly alternating between the heater and air conditioner.

MANUAL CONTROL BUTTONS ///

TEMPERATURE UP BUTTON

Adjust the Current Schedule Temperature to a higher value

TEMPERATURE DOWN BUTTON

Adjust the Current Schedule Temperature to a lower value

MODE BUTTON

Select a Mode you want to change

ENTER BUTTON

Activate the selected Mode

8

THERMOSTAT DISPLAY ///

BACKLIGHT

User-activated backlight is activated momentarily for 10 seconds when any button is pressed or is switched on permanently when selected via the ‘Mode’ Button.

1

2

3

5

4

6

THERMOSTAT DISPLAY

DISPLAY KEY

1. CURRENT INSIDE TEMPERATURE

Celsius or Fahrenheit; Message - When MESSAGE mode is activated, the display will present a 40-character text message. A maximum of 4 messages, 150 characters each are stored.

2. DISPLAY ICONS

HEAT ON

COOL ON

FAN ON

A SETTING WAS CHANGED AT THE THERMOSTAT; SCHEDULE SETTINGS WILL RESUME

AT THE START OF THE NEXT PERIOD

MESSAGE

3. CURRENT TIME, DAY, AND DESIRED TEMPERATURE SETTING

4. CURRENT SCHEDULE

5. CURRENT PERIOD WITHIN CURRENT SCHEDULE

6. CURRENT MODE

9

TROUBLE SHOOTING ///

SYMPTOM REMEDIES

Power LED on the base unit does not light up

1. Be sure you are using the proper wiring from the HVAC system.

2. Be sure the 24V hot wire is plugged into the hot terminal and the 24V common wires is plugged into the common terminal.

The display unit is blank

1. Be sure you have connected the same color wire from the common terminal of the base to the common terminal on the display unit.

2. Be sure you have connected the same color wire from the Link terminal on the base unit to the Link terminal on the display unit.

3. Make sure the base unit is powered.

4. Make sure all terminal screws are tightly fastened.

5. Try a different set of wires.

The Status LED does not blink during range testing

The Heating/

Cooling system will turn off

1. Try to reposition the base unit.

2. Adjust the antenna, the preferred position is having the antenna in a vertical upright position.

3. Make sure the base unit is powered properly.

4. Try repositioning the antennas on the Gateway .

1. The minimum cycle time is set to 7 minutes, be sure to wait until this time has passed.

FAQ’S ///

HOW FAR AWAY CAN THE THERMOSTAT BE PLACED FROM THE GATEWAY?

Typically, up to 60-80 feet.

CAN I PLACE THE THERMOSTAT IN A DIFFERENT ROOM FROM THE GATEWAY?

Yes, the Thermostat and Gateway use radio frequencies to communicate. These frequencies can go through objects like walls, ceilings and floors

HOW MANY THERMOSTATS CAN I REGISTER WITH MY GATEWAY?

The Gateway can support up to 2 Thermostats.

IF POWER IS LOST DO I LOSE ALL OF THE THERMOSTAT SETTINGS?

No. The Thermostat has a built in battery backup. It will retain all settings after a power failure.

HOW MANY SCHEDULES CAN THE THERMOSTAT STORE?

The Thermostat stores one schedule at a time. It will display the current schedule’s name on the display unit.

HOW DO I CHANGE SCHEDULES?

You create and modify schedules from the website application. After a schedule is saved, it can be downloaded to the Thermostat.

I0

TECHNICAL SPECS ///

Alpha numeric display supports full text in most European languages

Large easy to read seven segment numbers and icons for easy readability and interface

Simple three button operation

Back lit STN LCD display for high contrast and long life

Two wire comms and power technology simplifies retro installation

Base unit placed near HVAC simplifies interface with the HVAC equipment

Distance of up to 100’ from thermostat base unit to gateway

Full scheduling support

Indoor use only

Support for Fahrenheit (ºF) and Celsius (ºC)

APPROVALS ///

FCC ID NUMBER: OU4-XWT380 / IC: 4576A

INSTRUCTION TO THE USERS (IF DEVICE DOES NOT CONTAIN A DIGITAL DEVICE)

The user is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.

INSTRUCTION TO THE USER (IF DEVICE CONTAINS A DIGITAL DEVICE)

This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules.

These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interferences will not occur in a particular installation.

If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and receiver.

• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

• Consult the dealer or an experienced radio/TV technician for help.

This equipment has been certified to comply with the limits fro a class B computing, pursuant to FCC Rules. In order to maintain compliance with FCC regulations, shielded cables must be used with this equipment. Operation with non-approved equipment or unshielded cables is likely to result in interference to radio and TV reception. The user is cautioned that changes and modifications made to the equipment without the approval of manufacturer could void the user’s authority to operate this equipment.

The term “IC:” before the certification/registration number only signifies that the Industry Canada technical specifications were met.

Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.

WARRANTY ///

This product has a one year manufacturer’s warranty which covers parts and labor only. In the unlikely event that you encounter a technical or quality issue, please contact Xanboo at 1.877.926.2661.

Xanboo will replace defective units within the warranty period.

II I2

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement