iNels Connection server User Manual

Add to my manuals
91 Pages

advertisement

iNels Connection server User Manual | Manualzz

Connection server

User manual 3.265

2017

Table of Contents

Connection server - User manual 3.265 ...................................................................................................1

Connection server EN ...............................................................................................................................4

Get started .................................................................................................................................................5

3.0 Settings iMM Control Center iMM Server ...........................................................................................6

Bookmark Server .................................................................................................................................7

iMM servers management .............................................................................................................8

Bookmark Configuration ......................................................................................................................9

Settings ........................................................................................................................................10

Upload or edit export.pub ............................................................................................................11

Bookmark System ..............................................................................................................................12

Network settings ..........................................................................................................................13

Shutdown server ..........................................................................................................................14

Restart server ..............................................................................................................................15

Restart server regulary ................................................................................................................16

NFS Server configuration ............................................................................................................17

Bookmark HA-BUS ............................................................................................................................18

iNELS3 .........................................................................................................................................20

KNX ..............................................................................................................................................21

KNX add actor to rooms .............................................................................................................22

KNX export group address ..........................................................................................................23

Bookmark RF Configuration ..............................................................................................................25

Settings ........................................................................................................................................26

Bookmark Zones ................................................................................................................................27

New zone .....................................................................................................................................28

Defined zones ........................................................................................................................29

No zone defined ..........................................................................................................................30

Bookmark Houses .............................................................................................................................31

Scene ...........................................................................................................................................32

Edit enterHouse or exitHouse ...............................................................................................33

Bookmark Security Scan ...................................................................................................................34

Trigger ralays ...............................................................................................................................35

Notify me if device obtains folowing state ...................................................................................36

Bookmark EventScript .......................................................................................................................37

Trigger Rules ...............................................................................................................................38

Bookmark A/C ....................................................................................................................................39

LG Clims ......................................................................................................................................41

CoolMaster ...................................................................................................................................42

Air Pohoda ...................................................................................................................................44

Atrea .............................................................................................................................................45

Universal 0-10V ...........................................................................................................................46

Bookmark Rooms ..............................................................................................................................47

New room ....................................................................................................................................48

List Rooms ...................................................................................................................................49

Edit .........................................................................................................................................50

Rename ..................................................................................................................................52

Bookmark Cameras ...........................................................................................................................53

New camera .................................................................................................................................54

Select the stream ..................................................................................................................56

No camera defined ......................................................................................................................57

List of cameras ............................................................................................................................58

Bookmark Miele .................................................................................................................................59

Miele .............................................................................................................................................60

Bookmark Intercoms ..........................................................................................................................61

2N settings ...................................................................................................................................63

New intercom account .................................................................................................................64

Update of asterisk settings ..........................................................................................................65

Intercom accounts .......................................................................................................................66

Bookmark Energy ..............................................................................................................................67

Energy management ...................................................................................................................72

Create counter IDM3 .............................................................................................................74

Bookmark Giom .................................................................................................................................77

Giom scene ..................................................................................................................................79

Edit .........................................................................................................................................80

Bookmark Manual ..............................................................................................................................81

Manual .........................................................................................................................................82

Bookmark Default Settings ................................................................................................................83

Reset all server settings to default .............................................................................................84

Reset all devices dependencies to default .................................................................................85

Bookmark Audit .................................................................................................................................86

Logged events .............................................................................................................................87

Others ................................................................................................................................................88

Control 4 ......................................................................................................................................89

Connection server EN

Connection server

Connection between iNELS BUS system units and another devices.

Connection Server - It serves as a connection between iNELS BUS system units and another devices because it allows communication between devices with different protocols. All devices can be then controlled through just one application. Besides common controlling of electro-installation, you can also control e.g. air condition, home appliances.

Connection server uses small but powerful computer Raspberry Pi with really low consumption with Linux operating system.

In comparison with iMM Server, multimedia is not implemented here.

Protocols

RPC

Elkonet

Miele

- communication with application smartphones and tablets

- communication with central unit iNELS BUS

- communication with home appliances Miele

Camcontrol - communication with IP cams

Artea - communication with air handling unit Atrea

Coolmaster - communication with gateway for air conditioning

Airpohoda - communication with air handling Airpohoda eLAN-RF - communication with wireless components iNELS RF Control

Get started

Commands are given in purple, e.g.:

Notice are given in orange:

Tips and tricks are given in green: sudo reboot

Connection server support set only one door intercom.

In list we can add and remove elements manually

Important application configuration commands in Linux (are entered in terminal): ifconfig finding IP address of station/server, similar to ipconfig in Windows mount umount

- command for connection of certain device (CD-ROM, network drive, etc.)

- command for disconnection of certain device man - command is used to format and display the man page for example. man mount sudo shutdown now - command shut down device Connection server from teminal sudo reboot - command reboot device Connection server from teminal

Putting Connection Server in run

a) Once you unpack Connection server, let the device stabilize at room temperature.

b) Insert attached SD card in the slot.

c) Connect the cabling (do not connect the supply yet):

Display HDMI device

LAN cable for ethernet port

Keyboard to USB port

d) After connecting power suply (adapter with micro USB connector) Connection Server will start automatically.

e) When starting the system you can watch opening of individual services on the screen. Some services do not open, and display FAILD in red; in majority of cases it is not a problem; and has no influence whats over on the run of Connection Server.

f) When start of services is completed, only one line requiring login name will appear on the screen.

Login: imm

Password: imm123

No characters display when writing a password in terminal

g) To find IP address after signup use command ifconfig

h) Further settings are performed via web interface iMM Control Center. And display device or keyboard need not be connected for the rest of time. Power supply, micro SD card with system and application and connection to network is sufficient to run Connection Server.

Never insert or remove the micro SD card for running Server Connection

3.0 Settings iMM Control Center iMM Server

<TOD

3.0 Configuration in iMM Control Center - Connection Server

IMM Control Center (the "iMM CC" hereinafter ) is web interface serving for settings iMM clients and iMM

servers. iMM CC is activated upon entering the address http://IPADDRESS:8080 in your internet browser.

Login by your password in factory installation is default: " admin ", password " imm123 "

If iMM CC does not open, connect via ssh to Connection server and enter type folowing in command: sudo /etc/init.d/imm-web admin restart .

SSH authorization Login: imm

Password: imm123

If you can change Default password in terminal: passwd imm n't

Putty is free software whitch can be used to make an SSH connection to iMM CC in windows platform

Website iMM CC will be automatic logout for inactivity after 15 minutes.

Bookmark Server

Bookmark Server

In bookmark Server you can control virtual servers (services), which are necessary for comunication with third party. For software diagnostic is possible each virtual server check status, stop or enforce run service.

All virtual servers you can control via Supervisor service link http://IPADDRESS:9001

iMM servers management iMM servers management

In menu iMM servers management we can control the virtual servers running on the server via a web interface. For software diagnostic is possible each virtual server check status, stop or enforce run service.

All virtual servers you can control via Supervisor service link http://IPADDRESS:9001

Bookmark Configuration

Bookmark Configuration

In bookmark Configuration is main settings impotrant for propertly function device Connection server.

Machine ID and Licence key are preset in factory default.

IP address format:

If central unit is behind the NAT or in the other network and routers is possible use port forwarding. You can set port forwarded (on router) to comunication port central unit (CU2 port 61682 ,CU3 port 9999).

Version CU Format Example:

CU2 [IPADDRESS]:[COMUNICATION_PORT] 10.5.15.12:8454

CU3 [IPADDRESS]:[HTTP_PORT]:[COMUNICATION_PORT] 10.5.15.12:8080:4562

Communication port - Elkonet for iMM server, Connection server, App iHC

HTTP port - is webserver CU3 with save file export.imm usually http://IPADDRESS/immfiles/export.imm

ASCI port

Password

- port for comunication CU3 using third-party protocol (telnet) for proper function you must

set first port in IDM software (optional)

- password for acces and control central unit set in IDM software (optional)

Example setup menu settings:

Settings

Settings

In the section Settings is main settings for setup Connection server whitch are IP address Central unit, server, password and ASCII port. Machine ID and Licence key are preset in factory default.

IP address format:

If central unit is behind the NAT or in the other network and routers is possible use port forwarding. You can set port forwarded (on router) to comunication port central unit (CU2 port 61682 ,CU3 port 9999).

Version CU Format Example:

CU2

CU3

[IPADDRESS]:[COMUNICATION_PORT] 10.5.15.12:8454

[IPADDRESS]:[HTTP_PORT]:[COMUNICATION_PORT] 10.5.15.12:8080:4562

Communication port - Elkonet for iMM server, Connection server, App iHC

HTTP port - is webserver CU3 with save file export.imm usually http://IPADDRESS/immfiles/export.imm

ASCI port - port for comunication CU3 using third-party protocol (telnet) for proper function you must set first port in IDM software (optional)

Password - password for acces and control central unit set in IDM software (optional)

Example setup menu settings:

Upload or edit export.pub

Upload or edit export.pub

In the section Upload or edit export.pub

you can upload export.pub file from softare IDM to Connection server and manual edit elements in web browser.

Function for upload export.pub is only for central unit iNELS 2

In the central unit iNELS3 will dowload export automatically when you press Load iNELS 3 export button .

In list we can add and remove elements manually

Bookmark System

Bookmark System

In bookmark System you can configure additional, network settings which will be stored on static

IP address. We recommend setting a static IP address for Connection server.

Shutdown - turn off Connection server

Restart server - reboot Connection server

Restart server regulary - schedule restart server at a specified time in a week

NFS Server Configuration - update share settings for Connection server

Network settings

Network settings

In the section Network settings you can set IP address manualy as static or dynamically allocate by DHCP server.

Example setup static IP addres:

Set static IP address is recommended for stable use. Information about network settings IP address, link

If you are using a dynamic IP address from DHCP server set the router to allocate always the same IP addresses

based on MAC addresses.

Shutdown server

Shutdown server

Press down Shutdown button to power off Connection server from a web interface.

For another turn on plug in power connector to Connection server

Restart server

Restart server

Press down the Reset button to restart Connection server from a web interface.

Restart server regulary

Restart server regulary

a week.

In the section Restart server regulary we can setup scheduled restart the server at a specified time in

Example settings restart server in monday six minut after the midnight.

NFS Server configuration

NFS Server configuration

Press down Update button to refresh NFS sharing settings in the file /etc/fstab. from a web interface.

Bookmark HA-BUS

Bookmark HA-BUS

In bookmark HA-BUS we can used for interconnection iNELS3 BUS and decentralized control system

KNX/EIB, which allows control from iHC app.

Second function to add more iNELS3 central unit.

Requirements for connect with KNX/EIB: Central unit iNELS or more

Router KNX

Export group address from program ETS3 - 5

Example connection with iNELS3 CU:

First, enter the IP address of the central unit iNELS3 next fill password (optional) and note to finish press down button

Add. After saving the settings will download export from central unit and elements will be added prefix "inels3" last letter (A-H) identify rank.

Fill IP address KNX router and Save button. After save settings was performed put export file group address

(see. KNX export group address ) and load export to system. Now you can check bookmark Configuration whether

the excerpt elements KNX, If yes you go to the tab Rooms and put in a selected room features KNX.

Example add device KNX to rooms in bookmark Rooms:

This manual does not describe the setting elements KNX only link two systems among themselves.

iNELS3 iNELS3

First, enter the IP address of the central unit iNELS3 and Add. After saving the settings will download export from central unit and elements will be added prefix "inels3" last letter (A-H) identify rank.

The prefix consists of two parts first one is "inels3" and second "A" (last char A-H) distinguishes, letter central unit between themselves.

For correct function with KNX/EIB would have filled a part of the KNX .

If the central unit does not have a password set, Password field will be empty.

Names without prefix in rooms will be converted automatically.

For last hardware revision Raspberry Pi 2 is possible add up to 8 pcs INELS3 central unit.

KNX

KNX

Enter the IP address of the router KNX and press Save button. After saving the configuration file we find export group addresses from the program ETS3 and upload KNX exports.

Check Configurations in the bookmark that contains a list of export elements KNX, if so go to bookmarks rooms and put in a selected room features KNX.

KNX add actor to rooms

Add KNX element to the Rooms

KNX elements put into a room in the same way as the elements iNELS, KNX recognise by prefixing "knx_".

Example add KNX device to rooms:

KNX export group address

KNX export group address

Export group addresses to format: 1/1 (Name/Add.) separate semicolon (;) the ETS 3 or higher.

Example export group addresses from ETS:

Before inserting the export it need to be more adapted behind the semicolon refill data type according element values (True, False, 0-255, 0-100) see. KNX DPT link

Example of data in a file supplemented Test_group.cvs:

"Group name";"Address"

Dimming;0/-/-

New Middle Group;0/0/-

Dim A;0/0/1;5

Dim B;0/0/2;5

Switching;1/-/-

New Middle Group;1/0/-

D;1/0/0;1 switch A;1/0/1;1 switch BCD;1/0/2;1

Shutters;2/-/-

New Middle Group;2/0/-

Shutters1;2/0/1

Shutters2;2/0/2

Sensors;3/-/-

New Middle Group;3/0/-

Temperature;3/0/0;9

A switch in example; 1/0/1; 1 has value as shown in Table 1 behind a semicon (True, False) means that a switch.

Data type Data Type Value

1

5

5.001

6

232

1 bit bool True | False

8 bit num 0-255

8 bit num 0-100

8 bit num -128 +127

3 byte num RGB [0,0,0] - [255,255,255]

Bookmark RF Configuration

Bookmark RF Configuration

Communication between wireless RF devices and Connection server is required smart box eLAN-RF.

To configure the RF devices: a) The list of supported INELS RF devices b) Insert elements into Elan RF using a Web interface or application iHC-MARF see. Manual eLAN-RF.

For control RF elements enable in the settings iHC-MA, iHC-TA.

Settings

Settings

For control RF devices in menu Settings insert IP address device eLAN-RF, which must already be configured from the web interface or applications IHC-MARF see. manual eLAN-RF.

Example settings:

Bookmark Zones

Bookmark Zones

Bookmark Zones is used to configure the zones for Connection server.

Zone:

Giom Meteostation: Giom 3000

To insert a fill zone name, IP address and choose type of zone change switch to yes.

Connection Server allows only insert zone meteostation Giom 3000 .

If you set-up a password authentication for webinterface Giom device tick exception - status.xml

New zone

New zone

In the section New Zone , configure the Connection Server allows you to add only one type of zone.

Giom Meteostation: Giom 3000

Example of a zone Giom:

View already stored zone:

Defined zones

Defined zone

In menu Defined zone are displayed saved zone.

Example of the stored zone Giom:

No zone defined

No zone defined

You do not have any saved zone to create a zone, go to create New zone .

Bookmark Houses

Bookmark Houses

Bookmark Houses is used to configures the scenes when entering or leaving the house. In app iHC-MA is function call "Monitoring arriving home", which recognizes the different technologies that the user is coming to your home and starts the scene enterHouse more datail about this function in manual app iHC-MA.

Example create a scene enterHouse:

Saved relays with state in the scene enterHouse:

For proper function must be enabled on your mobile GPS, and Google Location, mobile data and active

connection to Connection server.

Scene

Scene

In the section Scene configure scene for entering or leaving the house. In app iHC-MA is function call

"Monitoring arriving home", which recognizes the different technologies that the user is coming to your home and starts the scene enterHouse more datail about this function in manual app iHC-MA.

For proper function must be enabled on your mobile GPS, and Google Location, mobile data and active

connection to Connection server.

Edit enterHouse or exitHouse

Edit enterHouse or exitHouse

Edit scene enterHouse or Exit House.

Example add elemets to scene enterHouse:

Example add elemets to scene exitHouse:

Bookmark Security Scan

Security Scan

Security Scan is a security feature that checks the status of Miele appliances if you are running is displayed in the table Security scan report to all run iHC app. Security scan can be set to monitor the status of selected elements in the house.

Security function - Security scan not finish in all iHC app.

Trigger ralays

Trigger ralays

In the section Trigger relays is main configuration for security relay for notify about preset states devices and Miele appliances.

Notify me if device obtains folowing state

Notify me if device obtains folowing state

In the section Notify me if device obtains folowing state you can set condition monitoring states selected relay.

Example Security Scan:

Bookmark EventScript

EventScript

In bookmark EventScript creted events based on which the preset start script. The event is performed if the element reaches the set value of the event. You can use different kinds of elements relay, DAC. etc..

EventScript use ASCII protocol, whitch must be turn on in IDM program to free port and in bookmark

Configuration in iMM CC insert ASCII port for comunication.

Trigger Rules

Trigger Rules

In the section Tringer Rules you can create event based on which the run script.

Example created event :

Depending on the setting ASCI protocol set value in hex or DEC example.

50 in (HEX) is 80 (DEC)

EventScript run with all device modes (HEX , HEX with prefix and DECIMAL)

Bookmark A/C

Bookmark A/C is used to define the air-conditioning or heat recovery by third parties and their control through the application iHC.

Supported are:

LG Clims

CoolMaster, CoolMasterNet

Air Pohoda

Atrea

Universal 0-10V

LG Clims over the modul PI-485 over Advantech Adam 4571

CoolMaster series 1000D, 2000S, 3000T, 4000M, 6000L, 7000F, 8000HM, 9000M, CoolMasterNet over Advantech

Adam 4571

CoolMasterNet

Other:

Atrea Duplex 180 EC4 P (0-10), Duplex 180 EC4 P (0-100)

AiRPohoda by Adam 4571

Universal 0-10V by DAC 0-10V

Daikin

Fujitsu

Gree

Hitachi

Intensity

Kentatsu

LG

Midea

DK)

(FJ)

(GR)

(HT)

(MD)

(KT)

(LG)

(MD)

Mitsubishi Electric

Mitsubishi Heavy

Panasonic

Samsung

Sanyo

Toshiba

Trane

Compatibility: indoor, outdoor unit link

(ME)

(MH)

(PN)

(SM)

(SA)

(TO)

(TR)

LG Clims

LG Clims

In the section LG Clims is used to define air conditiong LG corporation. Supported are units with communications board PI485 . LG air conditioning must be installed via RS485 - LAN, for example through device Advantech Adam 4571.

Example stored LG air condition:

CoolMaster

CoolMaster

Is used to define air conditiong by universal control unit Coolmaster and control through the application iHC.

Firs step:

First, set the control unit Coolmaster according to the manufacturer's manual. (usually via DIP switches inside the unit) Setup converter LAN-serial485 (Recommended converter: Adam 4571) according to

Coolmaster manual and connectconverter with control unit Coolmaster.

Test comunication:

If the air conditioner control unit is properly connected to Coolmaster the display alternately displays the temperature and mode.

Second step:

Moving on to set the air conditioner in the web interface, http://localhost:8080/clims and fill name and

IP address convertor and press button Save the settings wait for load UID air condition in system.

Now you can select the number of units and save CoolMaster unit.

If unsuccessful use reload button and check the air conditioning load UID communication converter with

CoolMaster according to the manual .

Example stored Coomaster unit :

For older Coolmasters version is necessary to set convertor to appropriate port.

Coolmaster type: 1000D, 2000S, 3000T, 4000M, 6000L, 7000F, 8000I(HM),

9000M

Convertor: Adam 4571 nebo Gnome 485

CoolMasterNet (default setup)

Port: 10001

Port: 10102

Perform the function check via utility ncat command format: ncat IPADDRESS PORT

Example ncat in terminal:

Command

Command ncat 10.10.10.111 10102

Answer

Command

> stat2

Answer 000 OFF 25C 27,80C High Heat OK 0

For windows you can use SPU (Serial port utility)

Significance

Connection to Cooler Master / Convertor

Returns the character command line

List states Air conditions

Return state Air condition

Commands and pin setup for cable connection air condition can be found in the reference manual for example:

CoolMasterNet

Maximal number of simultaneous connections for CoolMasterNet is 4 for convertor Adam 4571 only 2.

Air Pohoda

Air Pohoda

Is used to define Air recovery call Air pohoda and control through app iHC. AirPohoda air recovery must be connected via RS485 - LAN, for example through device Advantech Adam 4571.

Example stored Air recovery:

Atrea

Atrea

Is used to define Air recovery call Atrea and control through app iHC. Atrea Air recovery must be installed via RS485 - LAN, for example through device Advantech Adam 4571.

Example stored Air recovery:

Universal 0-10V

Universal 0-10V

Is used to define universal air conditiong using DAC 0-10V and control through app iHC.

Example stored Air condition:

Bookmark Rooms

Bookmark Rooms

Bookmark Rooms is used to configuration souboru rooms.cfg, for loading applications iHC..

More information in the manual iHC. Rooms are actually "virtual rooms" (groups), which have the option to group the icons and zones for one or more screens.

Name of room allows the use only characters A-Z, a-z, 0-9, -_.

New room

New room

Used to define rooms for applications iHC.

Example imposed rooms:

Name of room allows the use only characters A-Z, a-z, 0-9, -_.

List Rooms

List of rooms

Listing stored rooms on the server for applications iHC.

Edit

Devices of rooms

In menu Devices of room is used for editing rooms for application iHC.

Example add device to room House:

Example create scene:

For scene control can be programmed to use a script that can execute various functions defined in it. It is necessary to keep an absolute path starting with "/" and ending with the suffix script ".py" (python).Example: /home/imm/ skript_lights.py

Type device (icon filter devices) example. type Lamp filtred devices to dimmed devices.

Read only is a feature that change icon fuction "no" control device or "yes" icon can't control only information obout device state.

Rename

Rename

In the section Rename you can change name of room for app iHC.

Example rename "Room" to na Living room:

Bookmark Cameras

Bookmark Cameras

Bookmark Cameras is used for define IP cameras, which you want monitor and control by application iHC.

HTTP and RTSP port are filled only if you have an IP camera configured to access from outside local network. If the camera remotely connect via HTTP port, so you get to the web interface and you can fully control the camera.

If via RTSP, then you will get only a stream cameras. More about setting and ports see. instruction manual for the camera.More about setting and ports see. manual for the camera.

If you do not fill HTTP or RTSP ports remain in default, HTTP port 80, RTSP port 554

New camera

Supported cameras are: iNELS cam

AXIS protokolu VAPIX2 od verze firmwaru kamery 4.0.X.X a VAPIX3 od firmwaru 5.0.X.X

Kamery with Onvif protocol profile S. s certifikací Onvif link

Example integration cam Axis supported Onvif:

Connect the camera according to camera manual and create a user for ONVIF protocol might be different according to manufacturer.Setup a profile video stream: for applications iHC to mjpg/jpeg to second stream rtsp for Connection server. If camera supported video stream only over rtsp:// protocol set-up codec to MPEG4 and

HTTP port - iHC to 554.

New camera

In the section New camera is used for define IP cameras to Connection server.

Example integration cam Axis supported Onvif protocol:

Connect the camera according to camera manual and create a user for Onvif protocol might be different according to manufacturer.Setup a profile S video stream: for applications iHC to mjpg/jpeg to second stream rtsp mpeg4/H246 for Connection server. If camera supported video stream only over rtsp:// protocol set-up codec to

MPEG4 and HTTP port - iHC to 554.

Service port is usually set-up to 80. If the camera is behind NAT must be redirected port-forwarding on a router

servis port too otherwise the camera will not be configured.

Ports in factory defaults:

Axis Onvif camera HTTP port: iHC: 80 RTSP port - iMM: 554 Support in application: iHC-MA,TA,Mi, Ti

Others Onvif camera HTTP port: iHC: 554 RTSP port - iMM: 554 Support in mobile stream over rtsp: only in app.

iHC-MA,TA !

Add video profile for mobile app iHC.

List saved cameras:

Select the stream

Select the stream

In the section Select the stream you can choose specific camera streams assign to mobile app iHC.

Example:

No camera defined

No camera defined

You have no defined cameras at Connection server.

List of cameras

List of cameras

Menu List of cameras show saved cameras Connection server and options for remove selected camera.

Bookmark Miele

Bookmark Miele

In bookmark Miele set IP address device Miele gateway, that serves remote control of appliances over powerline, or ZigBee protocol.

Supported are: XGW 2000, XGW 3000 (Firmware 1.1,1.2)

Set IP address MieleGateWay is stored in the file /etc/imm/miele

Miele

Miele

In the section Miele set IP adresu device Miele gateway, that serves remote control of appliances over powerline, or ZigBee protocol.

Supported are: XGW 2000, XGW 3000 (Firmware 1.1, 1.2)

Set IP address MieleGateWay is stored in the file. /etc/imm/miele

Relay for restart GW is used for power off /on if gateway lost network connection and sended

notification on user email.

Bookmark Intercoms

Bookmark Intercoms

Bookmark Intercoms is used for define 2N settings and VOIP accounts for applications iHC.

In the section 2N settings set access (username, password) and lock code for open door (2N IP intercoms).

Setting the following Username and Password access data on the web interface 2N and Lock code set value to relay 2N intercom.

Connection server support set only one door intercom for open via DTMF .

Supported IP intercoms are :

2N Helios Verso

Helios Force

Helios Safety

Helios Vario

Unitech Tashi MT 200L

2N settings

In the menu 2N settings set access (username, password) and lock code for open door (2N IP intercoms).

New intercom account

In the menu New intercom account creating VOIP accounts on server side for applications iHC.

Update asterisk settings

Butoon Apply settings activated VOIP newly created accounts.

Intercom accounts

In the menu Intercom accounts are shown VOIP account for Connection server.

Example of an embedded account intercom 2N:

Intercom from the company 2N are inserted so that the Contact name contained the word "intercom" for example: intercom2, Intercom_Entry etc. capitalization does not matter.

According to the phrase "intercom" in the name of the application will recognize that this is a sound and allow the door opening preset Lock code, if we choose a different name for intercom will behave like an ordinary contact and opening function must be set manually in the mobile app.

For open switch intercom 2N setup signal DTMF first in web interface Connection server

Intercoms > 2N settings or in app iHC.

Stream for camera 2N add in format rtsp://IPADDRESS

Manual link for video intercom app iHC add in contact intercom to field IP address in this format: http://IPADDRESS/enu/camera640x480.jpg

In the case of multiple IP intercom 2N must be set all intercoms for open relay identically (User name,

Password, Lock code)

2N settings

2N settings

In the section 2N settings set access (username, password) and lock code for open door 2N IP intercoms.

Setting Username and Password are access datail on the web interface 2N and Lock code set value for switch to relay 2N intercom.

Connection server support set only one door intercom for open via DTMF .

Supported are IP intercoms :

2N Helios Verso

Helios Force

Helios Safety

Unitech

Helios Vario

Tashi MT 200L

In the case of multiple IP intercom 2N must be set all intercoms for open relay identically (User name,

Password, Lock code)

New intercom account

New intercom account

In the menu New intercom account creating VOIP accounts on server side for applications iHC.

Stream for cam 2N add in format rtsp://IPADDRESS

For view in application iHC must be stream format mjpeg

Update of asterisk settings

Update asterisk settings

Button Apply settings activate the newly created accounts VOIP and restart asterisk PBX .

Intercom accounts

Intercom accounts

In the menu Intercom accounts are shown VOIP account for Connection server.

Example of an embedded account intercom 2N:

Intercom from the company 2N are inserted so that the Contact name contained the word "intercom" for example: intercom2, Intercom_Entry etc. capitalization does not matter.

According to the phrase "intercom" in the name of the application will recognize that this is a sound and allow the door opening preset Lock code, if we choose a different name for intercom will behave like an ordinary contact and opening function must be set manually in the mobile app.

For open switch intercom 2N setup signal DTMF first in web interface Connection server

Intercoms

2N settings or in app iHC.

Stream for camera 2N add in format rtsp://IPADDRESS

Manual link for video intercom app iHC add in contact intercom to field IP address in this format: http://IPADDRESS/enu/camera640x480.jpg

In the case of multiple IP intercom 2N must be set all intercoms for open relay identically (User name,

Password, Lock code)

Bookmark Energy

Bookmark Energy

Directly in iHC aplication the amount of energy consumption can be clearly displayed.

Energy is recounted based on the amount of impulses that provide outputs from meters (gasmeters, electrometers, water-meters). Impulses are further processed in an optional input unit of system iNELS (IM2-140M, IM2-20/40/80B) in form of a counter. This value is by means of export.pub

transferred to Connection Server where variable is in iMMCC on bookmark Energy assigned to

Watter/Gas/Electrical. The setting of pulse conversion to unit of measure, selection of currency and setting the currency/unit is performed in iMMCC application in activated Energy module. The

Energy module allows recording of consumed energy for a day, week, month and year. Data are saved in Connection server – the data do not get lost even in case of power shutdown or power cut.

Consumption can be displayed in a table or graph.

The absorbed energy is shown in quantity but also in financial value.

The list of supported measuring devices, which have a pulse output, can be found here:

1. Click on the System Configuration button (icon of hammer and screwdriver – F11)

2. Select bookmark System -> counters

3. Add counter that you name by energy you want to measure

4. Create a new action that you name e.g. upload electricity

5. Add a command in the action which will be user action -> commands for counters -> increment counter

6. Select counter that corresponds with given action (e.g. for upload electricity you put counter electricity)

7. Add the action created as described above in system configuration to relevant binary input in action line when the input closes

8. Once the file export-pub is created and uploaded to iMM server, in bookmark Energy you can assign in the counter value line (electricity_VALUE). It must be VALUE in the line.

Connection of energy meter

Energy meter connects by means of a binary output unit. Output from supported energy meter is distinguished to + a -, that’s why polarity has to be maintained by bringing – minus to GND terminal and + plus to IN terminal.

Creation of counter in iDM:

Creation of action “Counter incrementing":

Action assignment to binary input where output from measuring instrument is connected.

Assign counter value in iMM Control Center

Example:

1 kWh = 100,- Kč = 100 pulzů

Base Unit – kWh

Impulses – 100 per 1 kWh

Price – 1 per 1 impulse

Create counter in sowftware IDM3 see. Create counter IDM3

Energy management

Energy management

In the section Energy management select binary inputs for WATER, GAS, ELECTRICITY and adding them to unit, impulse, currency.

Example Energy management:

Create counter see. bookmark Energy

Create counter IDM3

Create counter IDM3

Create counter in software IDM3

In bookmark M anagers , select the System Manager and go to the tab Counters where we create a counter name.

Creating functions for counter

In the Functions tab, select the Function Manager and create a function called Energy Increment

Move the switch and central units to the desktop and double click on switch icon edit and select IN Digital input

M3-80B.

In the Function tab, select ADD connections , make the connection by pulling the wire from the switch icon on the icon and select Central Unit Energy.

In the tab, Function select Wire Manager , select the input (IN) Energy through button the Edit function to adjust to Action: Short down User function: Energy Increment.

Add the created counter to iMMCC Energy management

Bookmark Giom

Bookmark Giom

Scene

In the tab Giom creating scenes based on data from weather stations Giom and their reactions

electro installations iNELS.

In the bookmark Giom creating a scene according to data from the weather station call Giom

Scene will be activated if selected value is higher or lower then set and assigned to units.

Edit scene

Connect Giom station as zone:

IMM connection with the server is defined in iMMControl Center in the "Zones" where it is necessary to state "Is it Giom?" switch from "no" to "yes".

To integrate Meteo Station you need to change its IP address to an address of the given range.

Settings can be performed via web interface. Meteo station IP address can be found out using the "Mlocator" software whitch can be downloaded in the manafacture's website: link

For proper function you must first set up Giom such a zone.

If you set-up a password authentication for Giom web interface tick exception - status.xml

Information from meteo station can by displayed in applications iHC

Giom scene

Giom Scene

In the bookmark Giom creating a scene according to data from the weather station call Giom

Scene will be activated if selected value is higher or lower then set and assigned to units.

Edit scene:

For proper function you must first set up Giom such a zone.

Information from meteo station can by displayed in applications iHC

Edit

Edit

Edit is used to create or edit scenes. In the selected scene type is possible add or remove relay units.

Example Edit selected scene:

Bookmark Manual

Bookmark Manual

In bookmark Manual is available for download the latest version of the manual in PDF format.

Manual

Download manual

In the section Download manual you can download the current version manual for Conncetion server

in PDF format.

Bookmark Default Settings

Bookmark Default settings

Bookmark Defualt settings is used for reset settings to default state. The first option offers is Reset all clients settings to default to reset Connection server to factory default ie. remove all users settings.

The second option is Reset all devices dependencies to default, whitch only remove users settings related dependencies to other functions Connection server.

Reset all server settings to default

Reset all server settings to default

Reset all server settings to defalt is used to reset Connection server to factory default i.e.that all user settings will be erased.

Reset all devices dependencies to default

Reset all devices dependencies to default

Menu Reset all devices dependencies to default, remove settings which are depending on other functions Connection server for example relay,air conditiong etc.

Bookmark Audit

Bookmark Audit

Bookmark Audit is used to show and download LOG file option events for diagnostic purposes developer.

Logged events

Logged events

Menu Logged events is used to show a download LOG option events for diagnostic purposes developer.

Integration Control 4

Others

Control 4

Control 4

Interconnection Control4 system with iNELS electrical installation via Connection server

Requirements for Control4 integration Central unit iNELS3

Director unit HC-250, HC-350, HC-800, EA-3, etc.

Composer software (2.7.2, 2.8.1, 2.8.2 and higher)

Connection Server 3.219 and higher

Setting up is made in Composer licensed program, the first step is to save iNELS drivers: iNELS3_Master_Driver.c4i

- Main driver establish the connection between Connection Server to C4 iNELS3_Switch.c4i

iNELS3_Dimmer.c4i

iNELS3_PIR.c4i

- Switching unit, SA3

- Dimming units DA3, DAC3

- Intrusion monitoring motion PIR sensor via the input IM3 iNELS3_RGB.c4i

iNELS3_Therm.c4i

iNELS3_Thermostat.c4i

iNELS3_Blinds.c4i

- RGB light control using RFDA-73m / RGB

- Temperature sensor

- Thermostat produced in IDM (heating, cooling, combined)

- Shutters/Blinds driver for JA3 / 20B / DC, SA3 copy all the files to the location C:\Users\ user \Documents\Control4\Drivers and run Composer pro.

(Windows)

Connect to the IP address of the control unit C4 (Director), and then put into the project iNELS3_Master_Driver , and set the IP address of the Connection server.

Addition iNELS3 Driver to the project

Procedure: Switch to the System design menu and continue Items window, where the tab Search and scan a string "iNELS" and insert the selected driver to the project.

The first add iNELS3 Master Driver and after that load other iNELS3 drivers

Insertion IP addresses to the Master Driver

Procedure: Go to the Connections menu where select iNELS3 Master Driver and continue on the top bookmark Network , after that open iNELS 3 Master Driver and enter the IP address.

Example of inserting the dimmer to ovaldače iNELS3_Dimmer

First, select the unit from the list in bookmark Configuration in IMMCC , then

DA3-22M_OUT1_000021 Y B 17039361 REAL PUB_INOUT put in the project iNELS3 Dimmer where change device name  and put the address of the unit Device Address: 17039361.

Debug mode, it is an optional parameter, if you set the Print and log can verify the tab lua changeing states.

Example of inserting HEATCOOLAREA

 Add to project  iNELS3_Thermostat  where change device name  and continue in bookmark Properties:

First, select the unit address HEATCOOLAREA  stateTH from the list in bookmark Configuration in IMMCC

NameHEATCOOLAREA_StateTH 2181234690 Y B REAL PUB_INOUT

...

after that find address Cooling relay and Heating relay. If we only have a separate cooling circuit

Or or heating. We will add the missing item to the system bit that we create only for this purpose in program IDM.

Next, we set the preset minimum temperature, attenuation, normal, comfort for the heating and cooling area separated

Commands "," if we only have a separate circuit, we will add to the missing area the opposite value according picture above.

Debug mode, it is an optional parameter, if you set the Print and log can verify the tab lua changeing states.

After setting up in software Composer pro reboot C4 director.

Note:  Thermostat you can change manual mode (attenuation, minimum, normal, comfor) in default only to the next

timestamp. Manual temperature set point in the application is not yet supported.