advertisement
J20542
UL Hospital Listed
“Energy Star” Certification
High-Performance Video System with up to 539 LOR
Secondary Audio Program (SAP)
Sound Logic™ Audio Leveler
Volume Limiter and Initial Volume
181-Channel Tuning**
Channel-Guide with One-Button Access
Closed-Captioning with
“Caption Vision”
126 Custom 8-Character Channel Labels
Optional Remote with
TV1/TV2 Capability
English/French/Spanish Menus and Displays
Initial Channel, Channel Lists,
Channel Hold
Power Provisions for
Third-Party Modules
Digital Serial Communications
Interface (DSCI)
Configuration Menus with
Non-Volatile Memory
Selectable Weak Signal Muting
Selectable Clock and Scheduler
Selectable Automatic Turn-off
IR and Wired Cloning Capabilities
Pendant Jack
Rear A/V Jacks
LED Power Indicator
Front Panel Lockout
Configurable “V-Chip Technology”
De-Commercialization
Commercial Warranty
20 " Monitor- Receiver
Energy Star
Certified
Pillow Speaker
Compatible
ClonePRO™
Programming
One-Button
Channel Guide
8-Character
Channel Labeling
Clear Safety Plug
www.rcacommercial.com
J20542 Healthcare
Picture
High-Performance Video System with advanced circuitry to deliver outstanding picture performance, with up to 539 lines of horizontal resolution*
Sound
SAP (secondary audio program) where available
Sound Logic™ Audio Leveler eliminates sound blasts during commercial breaks, maintaining a more consistent overall audio level
Volume Limiter and Initial Volume establish maximum and consistent initial volume settings each time television is turned on
Technical Specifications
Lines of Horizontal Resolution: 539*
Inputs: Audio (mono)
Video
RF Coax
Pendant Jack for pillow speakers
DSCI Port for interactivity
PATIENT REMOTE
PENDANT
VIDEO AUDIO
CABLE/
ANTENNA
DSCI PORT
Commercial Features
181-Channel Tuning for a wide range of options using off-air, satellite/ cable or internally generated program signals**
Channel-Guide with One-Button Access for an on-screen listing of all available channels and their identification labels
8-Character Channel Labeling allows for on-screen display of both network affiliation and channel number
Optional Remote with TV1/TV2 Capability allows simultaneous control of two monitors in the same room
“Energy Star” Certification saves energy costs
Power Provisions for Third-Party Modules eliminate the need for wall-transformers, wiring snarls and “set-top” boxes
Digital Serial Communications Interface (DSCI) allows third-party interactive systems to monitor and control television with optimal performance and efficiency
Pendant Jack features special healthcare isolation for optional pillow speakers, nurse-call units and bedside remote controls to provide the utmost in patient convenience and safety. Conforms to UL1492
Configuration Menus with Non-Volatile Memory for site-specific specifications and limitations on how televisions can be operated and retained, even when power is lost
Selectable Weak Signal Muting mutes audio, blanks video and provides an on-screen message if signal is weak or lost
Selectable Clock and Scheduler with automatic time set allows TV signal to automatically set time (where available); scheduled turn on/off events can be one-time or recurring
Selectable Automatic Turn-off permits television to turn off automatically after a period of inactivity
IR and Wired Cloning Capabilities allow rapid duplication of configuration information between televisions for ease of installation and maintenance
Front Panel Lockout prevents tampering
Decommercialization facilitates after-market resale and allows television investment recovery at the end of service life
Power Cord: 6-foot, 3-prong clear plug
Power Requirements: 120VAC (+/-)10%, 60Hz
Power Consumption: Stand-by: less than 3 watts (Energy Star Certified)
Operating: 90 watts
Cabinet: Construction: high-impact flame-retardant polystyrene
Finish: textured black
Dimensions: 19 1/8"H, 20 1/4"W, 18 7/8"D
Shipping Weight: 54 lbs. (approximate)
Certification: UL Healthcare Listing
Limited Warranty: 1 year parts and labor, 2 years picture tube
* Lines per picture width based on EIA measurement criteria.
** Check your cable company’s compatibility requirements.
*** This television receiver provides display of television closed-captioning in accordance with §15.119
of the FCC rules. This television does not support color attributes of television closed-captioning.
Optional Accessories
CBX203 ClonePRO™ Remote
This unique accessory developed by RCA significantly reduces installation and programming time, allowing you to program one television and then transfer the same data to all similar sets in just seconds. The more RCA televisions you install, the more efficiency you gain.
Hospital Jumper Cables
Connects television pendant jack to hospital wall plate, providing use with pillow speakers.
(JTA343 1/4” to 1/4”, JTA345 1/4” to 5-pin, JTA346 1/4” to RJ24)
Remote Controls
The User Remote provides easy access to television features with both the channel and scan buttons. The Master Remote maintains control of all setup menus, including audio and video functions.
COMMERCIAL PRODUCTS
©2002 Thomson Inc.
www.rcacommercial.com • Phone: 1-800-333-7221
Commercial Sales and Distribution • MS INH305
10330 North Meridian Street • Indianapolis, Indiana 46290-1024
Trademark(s) ® Registered Marca(s) Registrada(s) Printed in U.S.A. 12/02-5M
TV pictures simulated Specifications subject to change without notice.
LISTED BY
FOR HEALTHCARE USE
20542-0
advertisement