Kilotech KHS 200-300, KHS 200-60 User Manual
Add to My manuals17 Pages
Kilotech KHS 200-300 is an accurate and easy-to-use digital hanging scale with a capacity of 300kg/600lb, perfect for various weighing tasks. Its versatility is enhanced by multiple features like tare, hold, and unit conversion between kg, lb, and N. With its compact size, sturdy build, and long battery life, it's ideal for industrial, commercial, and even personal use.
advertisement
Content
1. Introduction .............................................................. 1
Notice ................................................... 1
Safety Guide ........................................ 1
2. Specifications ........................................................... 2
Features ............................................... 2
Specifications ...................................... 3
Capacity and Resolution ................... 4
Schematic Diagram ............................ 4
Dimension ........................................... 5
3. Operation Guide ...................................................... 6
Power On ............................................. 6
Power Off............................................. 6
Tare ....................................................... 7
Hold ..................................................... 8
Unit Switch .......................................... 8
Zero ...................................................... 9
Setting .................................................. 9
4. Trouble-shooting ................................................... 12
5. Note .......................................................................... 13
1.
Introduction
Notice
Before you use the scale, please read this manual through carefully, and keep it properly for future use.
Safety Guide
For good performance and precise measurement, be careful with daily operation and maintenance. Note the following instructions:
Do NOT overload the scale. This will damage the loadcell and void the warranty.
Do NOT leave load hung on the scale for long. This will decrease the scale’s accuracy and shorten the loadcell’s life.
Inspect shackle and hook before using.
When the scale runs out of power, replace the battery with fresh ones.
Do NOT use the scale under thunder or rain.
Do NOT attempt to repair the scale yourself.
Contact Kilotech at 800-694-4445, 877-328-5988 or www.kilotech.com.
Page 1 of 13
2.
Specifications
Features
This scale is a combination of the sound and proven mechanical design, with today’s most advanced electronics to provide a superb feature set. It is versatile, reliable, accurate and easy to operate.
Quality
Construction
& design
Power
In accordance with OIML R76,
GB/T11883-2002. ISO9001-2000 certified quality system.
Stainless steel load receptor and aluminum-casting case for better safety.
0.75 inch - 20mm LCD, visual distance over 10m. Dismountable hook.
SMT technology, quality integrated circuit and dedicated weighing loadcell, ensures long stability time.
3*AA battery with low power consumption design.
Page 2 of 13
Specifications
Accuracy Class Chinese GB/T 11883-2002 Class III
Equivalent to OIML R76
Tare Range 100% F.S.
Auto Zero
Manual Zero
± 50% F.S.
± 2% F.S.
0.5e/s Zero-tracking
Reading Stable
Time
≤10 seconds
Auto-sleep
Auto-off
Overload
Max. Safety
Load
Ultimate Load
Battery Life
Sable and no action in 3 sec.
Sable and no action in 3 min.
100% F.S. + 9e
120% F.S.
300% F.S.
>150 hours
Battery 3*AA battery
Temp. (Op.) - 10 ℃ ~ + 40 ℃
Humidity (Op.) ≤80% at 20 ℃ (non-condensing)
Display 0.7 inch (17.78mm) numerical
Net Weight 620g
Page 3 of 13
Capacity and Resolution
Model
Max. Cap.
(kg/lb)
30/60 KHS 200-30
KHS 200-60 60/120
KHS 200-150 150/300
KHS 200-300 300/600
E
(kg/lb)
Division
(n)
0.01/0.02 3,000
0.02/0.05 3,000
0.05/0.1 3,000
0.1/0.2 3,000
Schematic Diagram
Power
Loadcell
AD C
PGA
CPU
LCD
Key
Page 4 of 13
Dimension
Page 5 of 13
3.
Operation Guide
Power On
Press for 1 second to power up, battery tests and initializes.
Screen shows detection message while scale detects its load and auto-zero itself.
Power Off
Press for 1 second to power off scale.
Display shows power-off message.
Page 6 of 13
Tare
Press to store weight as tare.
“TARE” shows and weight turns zero.
If weight is over
100%F.S., or less than 0, tare is not allowed.
If weight is not stable or held, tare is not allowed.
Taring will reduce scale’s apparent overloading range. E.g., if a 10kg container is tared and scale’s maximum capacity is
50kg, scale will overload at a new weight of
40.18kg (5000 – 1000 + additional 9 divisions).
Press to restore tare.
“TARE” hides, and weight resumes in gross mode.
Page 7 of 13
Hold
Press to lock the display.
“HOLD” shows and display is frozen.
Press again to resume display.
“HOLD” hides and display resume refreshing.
Unit Switch
Press for 1 second to switch measuring unit between kg, lb and N.
If scale is tared, or held, unit switching is not allowed.
Page 8 of 13
Zero
Press for 1 second to zero scale.
“ZERO” shows and weight turns zero.
If weight is tared, or not stable, or held, zero is not allowed.
If weight is over Manual-Zero range, zero is not allowed.
Setting
Press and sim ultaneously, and hold the two buttons for 1 second, to enter Setting Mode.
Press to enter
Auto-Off option; and press to change
Auto-Off option.
Page 9 of 13
Auto-Off can be set to 0 (disabled), 5 (5min),
15 (15min), 30 (30min), 60 (60min).
Press to enter
Auto-Zero option; and press to change
Auto-Zero option.
Auto-Zero can be set to 0 (disabled), 2
(2%F.S.), 4 (4%F.S.), 10 (10%F.S.), 20
(20%F.S.), 50 (50%F.S.).
Press to enter
Manual-Zero option; and press to change
Manual-Zero option.
Manual-Zero can also be set to 0 (disabled),
2 (2%F.S.), 4 (4%F.S.), 10 (10%F.S.), 20
(20%F.S.), 50 (50%F.S.).
Press to enter
Backlight option; and press to change
Backlight option.
Backlight can be set to off (disabled), 5
(5sec), 15 (15sec), 30 (30sec), 60 (60sec), on
Page 10 of 13
(never).
When Backlight is set to 5, 15, 30, or 60, scale turns off backlight in corresponding seconds after it is stable.
When Backlight is set to off, backlight is disabled, and never turns on.
When Backlight is set to on, scale never turns off backlight, no matter it is stable or not.
Press to exit the
Settings Mode.
Page 11 of 13
4.
Trouble-shooting
Symptom blank display when
On/Off is pressed no action taken after TARE or
HOLD is pressed unstable readings reading is not zero without load large error in weight reading
Possible Causes discharged battery defective battery defective ON/OFF key
Solution replace battery press ON/OFF key for long defective TARE or
HOLD key clean TARE or
HOLD key scale in motion scale is damped dry the scale dust on PCB board clean PCB board unstable system power load-cell stressed too much or too long stabilize the load and scale longer warm-up time hang the scale in storage scale is not zeroed before loading re-calibration needed improper unit keep the scale unload and reboot re-calibrate the scale switch to proper unit
Page 12 of 13
5.
Note
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
Page 13 of 13
advertisement
Related manuals
advertisement
Table of contents
- 3 1. Introduction
- 3 Notice
- 3 Safety Guide
- 4 2. Specifications
- 4 Features
- 5 Specifications
- 6 Capacity and Resolution
- 6 Schematic Diagram
- 7 Dimension
- 8 3. Operation Guide
- 8 Power On
- 8 Power Off
- 10 Unit Switch
- 11 Setting
- 14 4. Trouble-shooting
- 15 5. Note