Apem Ø16 LB series - Buzzer switches Datasheet

Add to my manuals
15 Pages

advertisement

Apem Ø16 LB series - Buzzer switches Datasheet | Manualzz

Stylish and Functional

IDEC’s extensive range of LB/LBW series switches can be used for a wide range of applications.

F

lush Silhouette

Flush Silhouette

Projects only 2mm from the panel surface. For sleek and refined style.

2 mm

LB Series Flush Silhouette Switches

Slim 2mm-thick bezels for stylish panels.

LBW Series Flush Silhouette Switches

Smart appearance with large surface for secure operation.

LB Series

Bezel

ø22/  22mm

LBW Series

Bezel

ø26/  26mm

C

ontrol Unit

ø16mm LB Series

Miniature Switches and Pilot Lights

Short body for space-saving installation.

45 mm

27.9

mm

F

lush Silhouette

&

C

ontrol Unit

Removable Contact Block /Single Board Mounting

Removable contacts enable easy wiring / Single board mounting for space-saving installation.

Short Body

Depth of only 27.9mm behind panel.

Reduces the size of machines and control panels.

Compact

Detachable

Separate & One Board

Waterproof

Degree of protection: IP65

Waterproof

UP series

UP series has the same depth as LB/LBW series.

Mounts on the same panel.

(Flush bezel: 34.9mm, standard bezel: 27.9mm)

CW

LW-F

LB

LBW

UP

Flush Bezel

Flush Silhouette

ø16

ø22

ø30

Miniature

Pilot Lights

APEM

Switches &

Pilot Lights

Control Boxes

Emergency

Stop Switches

Enabling

Switches

Safety Products

Explosion Proof

Terminal Blocks

Relays & Sockets

Circuit

Protectors

Power Supplies

LED Illumination

Controllers

Operator

Interfaces

Sensors

AUTO-ID www.apem-idec.eu

B-072

APEM

Switches &

Pilot Lights

Control Boxes

Emergency

Stop Switches

Enabling

Switches

Safety Products

Explosion Proof

Terminal Blocks

Relays & Sockets

Circuit

Protectors

Power Supplies

LED Illumination

Controllers

Operator

Interfaces

Sensors

AUTO-ID

ø16 LB

-SERIES

Miniature Switches and Pilot Lights

(Standard Bezel)

Short

Shortest in the industry

(as of February

2011)

Panel depth of only 27.9mm.

Removable contact blocks ideal for single board mounting.

Protection degree: IP65 (IEC 60529) point

For space-saving installation

Actual Size

27.9

mm

Round

ø16.2

*

Square

 16.2

*

* Panel cutout (mm)

Illuminated

Pushbuttons

Pushbuttons

Marking plates can be used with lens style pushbuttons

*Does not light on.

Pilot Lights

Dome

Pilot Lights

Flush Silhouette

ø16

ø22

ø30

Miniature

Pilot Lights

LB

A6

B-103

Rectangular

16.2×24

*

With 3-sided barrier

With 3-sided barrier

With 3-sided barrier

Wave Key

Selector Switches

2- and 3-position selector switches.

Maintained and other various spring return actions available.

*Photo: knob operator (lever operator also available)

Illuminated selector switches available

Key

Selectors ensure safety

Seven different keys to choose from.

Key removable in desired positions.

Buzzers

Steady sound at 80 dB minimum (at 0.1m)

IP54 tab terminals, PC board terminal, and

IP40 solder terminals available.

IP54 IP40

Terminal side Terminal side

Illuminated

Pushbutton Color

Variations

Lever Switches

Degree of protection: IP67

Up/down operation.

2- and 3-positions available.

For 3-position switches, maintained and return two-way actions available.

Pushbutton Color

Variations

R (red) G (green) Y (yellow) A (amber) S (blue) PW (pure white)

www.apem-idec.eu

B (black) G (green) R (red) Y (yellow) S (blue) W (white)

ø16mm LB Series Switches and Pilot Lights

Buzzers

Specifications

Rated Insulation Voltage

Rated Operating Voltage

Operating Voltage Range

Current Draw

Inrush Current

Sound Pressure (at 0.1m)

Sound Frequency

Response Speed

Operating Temperature

Storage Temperature

Operating Humidity

Insulation Resistance

Rectangular

30V

12, 24V DC

12V DC±10%, 24V DC±10%

26mA

80mA maximum

Steady sound: 80 dB minimum

(at the rated voltage)

2.3±0.3kHz

50 ms maximum

–25 to +60°C (no freezing)

–30 to +80°C(no freezing)

45 to 85% (no condensation)

100 MΩ minimum (500V DC megger)

Name and Shape Operating Voltage

24V DC

Dielectric Strength

Vibration Resistance

Shock Resistance

Life

Degree of Protection

Terminal Style

Weight (approx.)

Between live and dead parts:

1,000V AC, 1 minute

Operating extremes/Damage limits:

5 to 55 Hz, amplitude 0.5 mm

Operating extremes: 100m/s 2

Damage limits:1,000m/s 2

1,000 hours minimum (beep sound)

LB3Z-1T0 * : IP54 (IEC60529)

LB3Z-104K: IP40 (IEC60529)

LB3Z-1T0 * : Solder/tab terminal #110

PC board terminal

LB3Z-104K: Solder terminal

11g (LB3Z-1T0 * ), 8g (LB3Z-104K)

• For applicable standards and UL, CSA ratings, see B-089 .

Terminal Style

Solder/tab terminal

PC board terminal

IP54 IP40

Solder terminal

• 12V DC operating voltages also available. Specify “ -1T04 ” in place of “ -1T03 ” in the Part No.

Example: LB3Z-1T03

IP54

LB3Z-1T04

LB3Z-1T04V

Part No.

IP40

LB3Z-104K

Dimensions

IP54

Terminal Arrangement

(Bottom View)

Buzzer terminal (+)

Buzzer terminal (–)

TOP

X1

X2

1 2.6

2-R0.6

Solder/Tab Terminal

LOCK

0.8W × 0.5t

Gasket

Locking Ring

Mounting

Ring

2.8W × 0.5t

Panel Thickness: 0.5 to 3.2 mm

0.6

APEM

Switches &

Pilot Lights

Control Boxes

Emergency

Stop Switches

Enabling

Switches

Safety Products

Explosion Proof

Terminal Blocks

Relays & Sockets

Circuit

Protectors

Power Supplies

LED Illumination

Controllers

Operator

Interfaces

Sensors

AUTO-ID

Flush Silhouette

ø16

ø22

ø30

Miniature

Pilot Lights

17.8

2

5.5

[PC Board Terminal]

8.8

7 20.9

[Solder/Tab Terminal]

9

23.8

LB

A6

IP40

Terminal Arrangement

(Bottom View)

TOP

Buzzer terminal (+)

Buzzer terminal (–)

X1

X2

Gasket

Locking Ring

Mounting

Ring

Panel Thickness: 0.5 to 3.2 mm

0.6

• For details on mounting hole layout, see B-110 .

• For details on pc board and circuit design, see B-121 .

• For details on single board mounting, see B-122 .

ø1.2

14.6

9

23.8

All dimensions in mm.

www.apem-idec.eu

B-118

LB/LBW Series

Mounting Hole Layout / PC Board Drilling Layout

LB Series Flush Bezel

Round (LB6/LB6M) Square (LB7/LB7M)

ø18.2

0

+0.2

18.2

+0.2

0

Rectangular (LB8/LB8M)

+0.2 0 24.2

+0.2

0

22

∗ 1

* 1: 23.2 mm for 3PDT contacts

* 2: 45 mm for switches with guard

LBW Series Flush Bezel

Round (LBW6/LB6M/LBW6G)

ø22.

3

ø22.3

+0.2

0.0

+0.2

0.0

22

∗ 1

28

Note: When using the LB series with a rubber boot or terminal cover, make sure to note the dimensions on B-128 .

Square (LBW7/LBW7M/LBW7G)

22.5

+0.2

0.0

LB Series Standard Bezel

(LB1/LB2/LB3)

ø16.

2

+0.2

0

26 26

* 53 mm for switches with guard

26 26

* 53 mm for switches with guard

Panel Cut-out for Positioning

LB Series Flush Bezel

Round (LB6/LB6M)

4-R0.5 or less

ø18.2

±0.1

LBW Series Flush Bezel

Round (LBW6/LBW6M/LBW6G)

ø22.3

+0.2

0

1.9

0

−0.1

18

∗ 1

* 1: 24 mm for rectangular type

23.2 mm for 3PDT contacts

* 2: 21 mm for 3PDT contacts

LB Series Standard Bezel

Round (LB1/LB2/LB3)

ø16.0

+0.1

0

1.9

±0.05

1.9

0.05

Approval Ratings and CCC Approval File No.

UL

Gold Contact

Rated Operating Voltage

Rated Operating Current

Silver Contact

Rated Operating Voltage

Rated

Operating

Current

AC

DC

Res.

Ind.

Res.

Ind.

CSA

Gold Contact

Rated Operating Voltage

Rated Operating Current

30V DC

0.1A

30V

2, 3, 5A

1A

30V DC

0.1A

125V

3.5 A

2A

0.4A

0.2A

125V AC

0.1A

125V DC

0.1A

250V

2, 3, 5A

1.5A

Silver Contact

Rated Operating Voltage

AC

Rated

Operating

Current

DC

Res.

Ind.

Res.

Ind.

30V

2, 5A

1A

125V

3A

2A

0.4A

0.2A

250V

2, 3, 5A

1.5A

TÜV

Gold Contact

Rated Operating Voltage

Rated Operating Current

Silver Contact

Rated Operating Voltage

Rated Operating

Current

AC-12

DC-12

CCC

Gold Contact

Rated Operating Voltage

Rated Operating Current

Silver Contact

Rated Operating Voltage

Rated Operating

Current

AC-12

DC-12 www.apem-idec.eu

30V DC

0.1A (DC-12)

30V

2, 5A

125V

3A

0.4A

125V AC

0.1A (AC-12)

250V

2, 5A

CW

LW-F

LB

LBW

UP

Flush Bezel

30V DC

0.1A (DC-12)

30V

2, 5A

125V AC

0.1A (AC-12)

250V

2, 5A

APEM

Switches &

Pilot Lights

Control Boxes

Emergency

Stop Switches

Enabling

Switches

Safety Products

Explosion Proof

Terminal Blocks

Relays & Sockets

Circuit

Protectors

Power Supplies

LED Illumination

Controllers

Operator

Interfaces

Sensors

AUTO-ID

Flush Silhouette

ø16

ø22

ø30

Miniature

Pilot Lights

B-120

LB/LBW Series

Notes for Designing PC Board and Circuit

All dimensions in mm.

• Use 1.6-mm-thick glass epoxy PC board with drilled holes.

• Design a circuit so that the LB/LBW series can operate within the rated voltage and current range. Make sure that inrush current and voltage do not exceed the rating.

• Minimum applicable load is 5V AC/DC, 1 mA on gold contacts. Applicable range is subject to the operating condition and load.

• Since the * 2.8-mm-wide terminal touches the PC board as shown on the right, short circuit may occur with pattern lines. Design a circuit that prevents short circuits.

APEM

Switches &

Pilot Lights

Control Boxes

Emergency

Stop Switches

Enabling

Switches

Safety Products

SPDT/DPDT Contacts

Lamp Terminal (+)

3.85

(0.5)

(0.5)

(0.5)

3.85

(0.5)

6.95

(0.5)

6.95

(0.5)

NC Terminal

1.6

(PC Board)

1.6

(PC Board)

1.6

(PC Board)

1.6

(PC Board)

Explosion Proof Lamp Terminal (−)

Terminal Blocks

Relays & Sockets

Circuit

Protectors

Power Supplies

+0.1 0

9-ø1.2

+0.10

9-ø1.2

LED Illumination

Controllers

Operator

Interfaces

Sensors

3PDT Contacts

(0.5)

(0.5)

(0.5)

(0.5)

8

8

8

8

AUTO-ID

+0.10

9-ø1.2

9-ø1.2

+0.1 0

COM Terminal

Soldered Side Mounting Side

Soldered Side

Lamp terminal

Mounting Side

Lamp terminal

Soldered Side Mounting Side

Switch terminal

Mounting Side

Switch terminal

(0.5)

(0.5)

NC Terminal

COM Terminal

Soldered Side

Soldered Side

1.6

(PC Board)

Mounting Side

Mounting Side

Flush Silhouette

ø16

ø22

PC Board Drilling Layout (Bottom View)

SPDT/DPDT Contacts

ø30

Miniature

Pilot Lights

8-ø1.2 (Note 2)

0.5

ø6 drilled hole for operating (Note 3) the locking lever

3PDT Contacts

9-ø1.2 (Note 2)

1.45

ø6 drilled hole for operating

CW

LW-F

LB

LBW

1.95 (Note 1)

8 8

3.85

6.95

UP

Flush Bezel Note 1: When designing, note the alignment of center lines of the contact blocks and center lines of the operators.

Note 2: The diameter of the terminal hole is ø1.2.

Note 3: Hole diameter may vary to meet installation requirements. Determine the location and the size of the hole so that the locking lever can be operated.

B-121

www.apem-idec.eu

LB/LBW Series

Single Board Mounting

IDEC’s LB/LBW Series is available for single board mounting.

Front Rear

ø6 drilled hole for operating the locking lever

LB Series Flush Bezel

SPDT/DPDT Contacts

LB6/LB6M/LB6G

ø18.2

±0.1

ø18.2

ø18.2

±0.1

±0.1

Installing and Removing Contact Blocks

Turn the locking lever to install and remove contact blocks on the

PC using a screwdriver from a hole in the PC board. See “Notes for

Designing PC Board and Circuit” on B-121 . Determine the location of the switches so that the locking lever can be operated. See “Removing and Installing the Contact Block” on B-131 .

Mounting Holes and Assembly Procedure

Drill mounting holes in the panel as shown below. When the units are mounted collectively, provide adequate clearance.

Panel Cut-out for Positioning

Standard Bezel

(LB1/LB2/LB3/LB4)

LB Series Flush Bezel

(LB6/LB6M/LB6G)

4-R0.5 or less

ø16.0

+0.1

0

ø18.2

±0.1

22 min

LB7/LB7M/LB7G

22 min

18.2

±0.1

18.2

±0.1

18.2

±0.1

22 min

22 min

22 min

24.2

±0.1

LB8/LB8M/LB8G

24.2

±0.1

24.2

±0.1

3PDT Contacts

ø18.2

±0.1

ø18.2

ø18.2

±0.1

±0.1

23.2 min

18.2

±0.1

23.2 min

18.2

±0.1

18.2

±0.1

23.2 min

23.2 min

24.2

±0.1

24.2

±0.1

24.2

±0.1

1.9

+_ 0.05

LBW Series Flush Bezel

(LBW6/LBW6M/LBW6G)

ø22.3

+0.2

0

1.9

0

−0.1

1.9

±0.05

28 min

28 min

28 min

* 45 mm minimum for switches with guard

LBW Series Flush Bezel

LBW6/LBW6M/LBW6G

ø22.

3

+0.2

0.0

28 min

28 min

28 min

LBW Series Flush Bezela

LBW7/LBW7M/LBW7G

+0.2

0.0

Mounting Hole Layout

Standard Bezel (LB1/LB2/LB3/LB4)

SPDT/DPDT Contacts

ø16.0

0

+0.1

3PDT Contacts

ø16.0

0

+0.1

18 or more

(24 or more for rectangular units)

23.2

or more

(24 or more for rectangular units)

CW

LW-F

LB

LBW

* 53 mm minimum for switches with guard

Assembly Procedure

1. Install the operator to the panel.

2. Mount the contact block to the operator from the rear.

3. Turn the locking lever to lock the contact block.

4. Insert the PC board to terminals and solder.

Note 1: Make sure that each terminal is inserted into the PC board correctly.

Note 2: Do not apply tensile force to the connector cable for an extended period of time.

Note 3: Do not expose the contact block to water.

Note 4: Ensure to lock contact blocks when the contact blocks are installed on the operators.

• UP series can be installed on the same board. For details, see B-123 .

UP

Flush Bezel www.apem-idec.eu

B-122

Flush Silhouette

ø16

ø22

ø30

Miniature

Pilot Lights

APEM

Switches &

Pilot Lights

Control Boxes

Emergency

Stop Switches

Enabling

Switches

Safety Products

Explosion Proof

Terminal Blocks

Relays & Sockets

Circuit

Protectors

Power Supplies

LED Illumination

Controllers

Operator

Interfaces

Sensors

AUTO-ID

LB/LBW Series

APEM

Switches &

Pilot Lights

Control Boxes

Emergency

Stop Switches

Enabling

Switches

Safety Products

Explosion Proof

Terminal Blocks

Relays & Sockets

Circuit

Protectors

Power Supplies

LED Illumination

Controllers

Operator

Interfaces

Sensors

AUTO-ID

Flush Silhouette

ø16

ø22

ø30

Miniature

Pilot Lights

Accessories

Locking Ring Wrench

Shape

ø18.0

Remarks

Package Quantity:1

Specification Part No.

Package

Quantity

Metal

(Nickel-plated brass)

MT-001 1

Used to tighten the locking ring when installing the units on to the panel.

60.0

Lens Removal Tool

180° Spring return

60.0

For round / square units

(LB1/LB2)

Stainless

Steel

Guard

(Polyacetal)

Base

(Polyarylate)

Spring return

180° Spring return for Single Board Mounting

For rectangular units

(LB3/LB4)

For rectangular units

(LB3/LB4)

Guard

(Polyacetal)

Base

(Polyarylate)

Spring return

Remains 110°/180° open

(Can be used for single board mounting)

MT-101

AL-K6SP

AL-KH6SP

LA9Z-K3

1

1

1

1

Used to remove the lens or button.

(for standard bezels)

Degree of protection: IP65

Used to protect pushbuttons and illuminated pushbuttons from inadvertent operation.

See B-127 for dimensions.

With the gasket mounted on the switch, attach the switch guard and mount on the panel.

Degree of protection: IP65

With the gasket mounted on the switch, attach the switch guard and mount on the panel.

See B-127 for dimensions.

110°

180°

For round / square units

(LB1/LB2)

For rectangular units

(LB3/LB4)

Guard

(Polyacetal)

Base

(Polyarylate)

LB9Z-K2

LB9Z-K3P

1

1

Degree of protection: IP40

Used to protect pushbuttons and illuminated pushbuttons from inadvertent operation.

See B-127 for dimensions.

With the gasket mounted on the switch, attach the switch guard and mount on the panel.

See B-136 for dimensions.

When using for single board mounting, remove the rubber gasket from the switch.

Degree of protection: IP65

With the gasket mounted on the switch, attach the switch guard and mount on the panel.

See B-127 for dimensions.

Rubber Boot

1. For round units

(LB1)

LB9Z-D1 1

➁ 2. For square units

(LB2)

Rubber

(Transparent silicon rubber)

LB9Z-D2 1

Degree of protection: IP65

See B-127 for dimensions.

See B-135 for mounting.

CW

LW-F

LB

LBW

UP

Flush Bezel

Mounting Hole Plug

3. For rectangular units

(LB3/LB4)

Metal

[Plug]

Metal

(Zinc diecast)

[Locking nut]

Polyacetal

[Gasket]

Nitrile rubber

LB9Z-D3

AL-BM6

1

1

Degree of protection: IP65

Tightening torque: 0.1 to 0.29 N·m

See B-127 for dimensions.

Mounting Hole Plug

Rubber

Nitrile rubber

(black)

AL-B6 5

Degree of protection: IP65

See B-127 for dimensions.

B-125 www.apem-idec.eu

LB/LBW Series

Accessories

Shape Specification

Rubber Boot

1. For round units

(LB6/LB6M)

2. For square units

(LB7/LB7M)

Rubber

(Transparent silicon rubber)

3. For rectangular units

(LB8/LB8M)

Mounting Hole Plug

Mounting Hole Plug

Mounting Hole Plug

1. For round units

(LB6/LB6M)

2. For square units

(LB7/LB7M)

[Plug]

Polyamide (Black)

[Gasket]

Nitrile rubber

[Mounting Plate]

Stainless Steel 3. For rectangular units

(LB8/LB8M)

1. For round units

(LBW6/LB6W6M)

2. For rectangular units

(LBW7/LB6W7M)

Metal

[Plug]

Polyamide (Black)

[Gasket]

Nitrile rubber

[Mounting Plate]

Stainless Steel

[Plug]

Zinc diecast

[Locking Ring]

Polyamide

[Gasket]

Nitrile rubber

Mounting Hole Plug

Rubber Nitrile rubber

Part No.

LB9Z-D6

Package

Quantity

1

LB9Z-D7

LB9Z-D8

Remarks

1

Degree of protection: IP65

See B-128 for dimensions.

See B-135 for mounting.

1

Package Quantity:1

LB9Z-BS6

LB9Z-BS7

LB9Z-BS8

*

*

*

LBW9Z-BS6 *

1

1

1

1

APEM

Switches &

Pilot Lights

Control Boxes

Emergency

Stop Switches

Enabling

Switches

Safety Products

Explosion Proof

Terminal Blocks

Relays & Sockets

Circuit

Protectors

Power Supplies

LED Illumination

Controllers

Operator

Interfaces

Sensors

AUTO-ID

LBW9Z-BS7 * 1

* Color code: blank (black), W (white)

Degree of protection: IP65

Panel thickness: 0.5 to 3.2 mm

See B-128 for dimensions.

* Color code: blank (black), W (white)

Degree of protection: IP65

Panel thickness: 0.5 to 3.2 mm

See B-128 for dimensions.

LW9Z-BM

LW9Z-BP1

Terminal Cover

➀ ➁

1. For SPDT/DPDT contacts

PBT

(White)

2. For 3PDT contacts

Key

Reversible key

For key selector switches

(wave key)

Metal

(zinc nickel-plated)

Keys

Non-reversible key

For key selector switches

(disc tumbler key)

Metal (brass nickel-plated)

18×1.8×25.1 t1.8

LB9Z-VL2

LB9Z-VL3

LA9Z-SK*

AS6-SK-132

1

1

Degree of protection: IP66

Tightening torque: 1.2 N·m

See B-128 for dimensions.

Degree of protection: IP65

Tightening torque: 2.0 N·m

See B-128 for dimensions.

10

10

See

See

B-128

B-131

for dimensions.

for mounting.

2

Specify a key number in place of * in the Part No.

Blank: Standard key 0H (reversible)

1H to 2H: Reversible key

3H to 6H: Non-reversible key

See B-128 for dimensions.

CW

LW-F

LB

LBW

UP

Flush Bezel

Flush Silhouette

ø16

ø22

ø30

Miniature

Pilot Lights

2 www.apem-idec.eu

B-126

LB/LBW Series

Maintenance Parts

LB Series Maintenance LED Unit

Shape Rated Operating Voltage

LED Unit

5V DC

Transformer

12V AC/DC

Transformer Primary Voltage

For 24V 100/110V AC

200/220V AC

400/440V AC

• Terminal cover (TWR-VL3) is supplied as standard.

• Connect one LB9Z-LED2 * to a transformer.

Part No.

(Ordering No.)

LB9Z-LED5 *

LB9Z-LED1 *

24V AC/DC

• All LB/LBW series contain an LED unit.

• Use a pure white (PW) LED unit for yellow (Y) illumination.

LB9Z-LED2 *

Secondary Voltage

100/110V AC ±10%

200/220V AC ±10%

400/440V AC±10%

Specifications

Part No.

Operating Voltage

Current Draw

TWR5  2

100/110V AC, 200/220V AC, 400/440V AC (50/60Hz)

2.4VA

Rated Insulation Voltage 600V

Insulation Resistance 100 MΩ minimum (500V DC megger)

Operating Temperature –30 to +60°C (no freezing)

Storage Temperature

Operating Humidity

Vibration Resistance

Shock Resistance

–40 to +80°C (no freezing)

35 to 85% RH (no condensation)

Damage Limits: 30 Hz, amplitude 1.5 mm

Operating extremes: 5 to 55 Hz, amplitude 0.5 mm

Damage limits: 1,000 m/s 2

Operating Extremes: 100 m/s 2

Dielectric Strength

Terminal Screw

Applicable Wire

Weight (approx.)

2,500V AC, 1 minute

M3.5

2 mm 2 maximum, 2 wires maximum

87g

Accessories

35mm DIN Rail

Part No.

BAA1000

BAP1000

Length

1,000mm

1,000mm

Material

Aluminum (approx. 200g)

Steel (approx. 320g)

Dimensions

M3.5

Terminal Screw

Secondary Side

2-ø3.3

Mounting Hole

Terminal Cover

40

48

52

Package Quantity

10

10

BAA1000

End Clip

Part No.

Applicable DIN Rail Package Quantity

Package Quantity: 1

* Color Code

A: Amber

G: Green

PW: Pure White

R: Red

S: Blue

W: White

Part No.

(Ordering No.)

TWR512

TWR522

TWR542

Dimensions

APEM

Switches &

Pilot Lights

Control Boxes

Emergency

Stop Switches

Enabling

Switches

Safety Products

LB9Z-LED2 *

Explosion Proof

Package Quantity: 1

Terminal Blocks

Applicable Load

(24V AC/DC LED unit)

Relays & Sockets

Circuit

Protectors

Power Supplies

LED Illumination

All dimensions in mm.

Controllers

Operator

Interfaces

Sensors

AUTO-ID

Primary Side

CW

LW-F

LB

LBW

UP

Flush Bezel

Flush Silhouette

ø16

ø22

ø30

Miniature

Pilot Lights

BNL6

BAA1000

BAP1000

10

Approx. 15g

Steel (Zinc-plated)

9.5

45

48.6

9

BC9Z-E/NS35N

BAA1000

BAP1000

10 Approx. 15g

• See H-071 for DIN rail products.

• Use end clip BC9Z-E/N35NPN10 when using 400/440V AC primary voltage transformers.

www.apem-idec.eu

B-130

LB/LBW Series

Safety Precautions

• Turn off the power to the LB/LBW series before installation, removal, wiring, maintenance, and inspection. Failure to turn power off may cause electrical shocks or fire hazard.

• To avoid burning your hand, use the lamp holder tool when replacing the lamps.

APEM

Switches &

Pilot Lights

Control Boxes

Emergency

Stop Switches

Enabling

Switches

Safety Products

Explosion Proof

Instructions

Wiring

1) Solder the terminals at 350°C within 3 seconds using a 60W soldering iron. Sn-Ag-Cu type is recommended when using leadfree solder. When soldering, do not touch the LB series with the soldering iron. Also ensure that no tensile force is applied to the terminal.

Do not bend the terminal or apply excessive force to the terminal.

2) Use non-corrosive liquid flux.

Terminal Blocks

Relays & Sockets

Circuit

Protectors

Power Supplies

LED Illumination

Terminal Cover

Solder/tab terminal

Insert the terminal cover into the contact block with the TOP markings on the contact block and the terminal cover in the same direction.

Note: When wiring, insert the lead wires into the terminal cover holes before soldering.

After wiring, the terminal covers cannot be installed.

Controllers

Operator

Interfaces

Sensors

Standard Bezel

Terminal Cover

AUTO-ID

• For wiring, use wires of a proper size to meet voltage and current requirements. Solder correctly according to the instructions in

“Wiring” and “Notes on Terminal Cover.” Improper soldering may cause overheating and create a fire hazard. Also, when using tab terminals, use receptacles of appropriate size.

Handling

Contacts (micro switch)

When using NC (normally closed) and NO (normally open) contacts of the same microswitch, avoid connections of different voltages, or connections of different types of power supplies. Failure to observe this instruction may cause a short-circuit.

Protection against oil (IP65)

The LB series has been tested according to JIS C 0920: Appendix 1 by using water insoluble cutting oil Class N3, No. 8 (JIS K 2241) to prove that the switches will not be damaged by oil drops or splashes. This may not apply to special types of oils. Contact IDEC for details.

Removing and Installing the Contact Block

1) Turn the locking lever on the contact block in the direction opposite to the arrow on the housing. Then the contact block can be removed.

2) Insert the contact block with the TOP markings on the contact block and the operator placed in the same direction. Then lock the units, turning the locking lever in the direction of the arrow.

Note: When removing/installing the contact block, or when using the contact block alone, do not apply excessive force on the actuator. Deformed actuator may affect contact operation.

Flush Bezel

Terminal Cover

Flush Silhouette

ø16

ø22

ø30

Miniature

Pilot Lights

CW

LW-F

LB

LBW

Operating Environment

• Do not use the LB/LBW series where corrosive gases exist or under an environment exceeding the operating temperature and humidity ranges. Otherwise, damages due to contact failure or change of surface color may occur.

• Major parts of the switch are plastic. Scratches or damages may occur when scraped with a sharp object or applied with excessive load or shock. Note that this may cause operation and appearance failure of the operator and bezel.

• Adherence of detergent, cutting oil, or special chemicals to the switch may result in operation failures and appearance failures such as change of surface color.

UP

Flush Bezel

Locking Lever

Actuator

B-131 www.apem-idec.eu

LB/LBW Series

Instructions

Panel Mounting

Remove the contact block from the operator. Insert the operator into the panel cut-out from the front, then install the contact block to the operator.

(For Standard Bezel)

TOP

TOP

(For Flush Bezel)

Panel

Panel

➀ Anti-rotation Ring

➁ Locking Ring

TOP

➀ Anti-rotation Ring

Panel Thickness: 0.5 to 6 mm

➁ Locking Ring

TOP

➂ Contact Block

➂ Contact Block

Notes on Mounting

Use the optional ring wrench (MT-001) to mount the operator onto the panel. The recommended tightening torque is 0.5 to 0.7 N·m. Do not use pliers. Excessive tightening will damage the locking ring.

Replacing the Lens and Marking Plate

Removing

[Removing the operator]

Standard Bezel

1) From the opposite side of the TOP marking, remove the operator

(lens, marking plate, and lens holder) using the optional lens removal tool (MT-101) by gripping the recesses of the color lens.

Flush Bezel

1) From the opposite side of the TOP marking, push the tip (width: 3 mm, thickness: 0.5 mm) of the flat screwdriver to the groove of the color lens and pull out the operator (lens, marking plate, lens holder).

Note: For metallic bezels, the bezel may be damaged if the screwdriver is inserted from the TOP side or inserted deeply or with force into the groove of the lens.

TOP

Remove from the opposite side of the

TOP marking

APEM

Switches &

Pilot Lights

Control Boxes

Emergency

Stop Switches

Enabling

Switches

Safety Products

[Removing the Operator]

2) Remove the marking plate by pushing the lens from the rear to disengage the latches between the lens and holder, using the screwdriver as shown below.

Explosion Proof

Terminal Blocks

Relays & Sockets

Circuit

Protectors

Power Supplies

LED Illumination

Controllers

Operator

Interfaces

Sensors

AUTO-ID

Note: The translucent in the lens holder cannot be removed because this filter is sealed to make the unit waterproof and oiltight.

LBW Series Pushbutton (button style)

LBW series pushbuttons (button style, see B-097 ) can be removed according to the following procedure. LBW series pushbuttons (button style) cannot be removed from the front of the panel.

[Removing the Operator]

1) Detach the operator unit and contact block. (See Removing and

Installing the Contact Block on B-131 )

2) Remove the button unit (button, button holder) by pushing out the cross-shaped protrusion (white) at the back of the operator with a screwdriver.

Flush Silhouette

ø16

ø22

ø30

Miniature

Pilot Lights

LBW Series Illuminated Pushbutton (round extended)

Screw-in lens. The lens can be removed by turning anticlockwise.

CW

LW-F

LB

LBW

UP

Flush Bezel

Push out the cross-shaped protrusion (white) from the back of the operator unit.

www.apem-idec.eu

B-132

LB/LBW Series

Instructions

Removing the Button

The button can be removed by inserting a small screwdriver into the groove of the button holder.

Miniature screwdriver Button holder (white)

Installing the Lens Unit and Contact Block

To insert the lens unit into the operator, press in the lens unit by making sure that the latch on the operator is aligned with the latch on the lens unit.

Round Lens Unit Square Lens Unit

Latch Latch

APEM

Switches &

Pilot Lights

Control Boxes

Emergency

Stop Switches

Enabling

Switches

Safety Products

Button holder groove Button

To attach the button to the button holder, align the groove on crossshaped protrusion with the positioning protrusion on the button and insert securely.

Installing

Explosion Proof

Terminal Blocks

Relays & Sockets

Circuit

Protectors

Power Supplies

Cross-shaped protrusion

Button holder (white)

Positioning protrusion

Button

LED Illumination

Controllers

Operator

Interfaces

Sensors

Insert the marking plate into the color lens, and press the lens onto the lens holder to engage the latches. Pay attention to the orientation of the marking plate.

LB/LBW Series Round

Latch Slit

AUTO-ID

Standard Bezel

Flush Bezel

TOP

Latch

Latch

TOP Latch

Recess

TOP

Latch

Recess

Operator

TOP

TOP

Latch

Latch

Latch

Operator

Square Lens Unit

Latch

TOP

Latch

Latch

Color Lens

Engraged

Area

Marking

Plate Flush Silhouette

ø16

ø22

ø30

Miniature

Pilot Lights

LB Series Square/Rectangular

Latch Slit

Color Lens

Engraged

Area

Marking

Plate

CW

LW-F

LB

LBW

UP

Flush Bezel

LBW Series Square

Latch Slit

Color Lens

Engraged

Area

Marking

Plate

Lens Holder

Lens Holder

Lens Holder

Marking Plates and Films

For illuminated pushbuttons, pushbuttons with lens, and pilot lights, legends and symbols can be engraved on the marking plates, or printed film can be inserted under the lens for labelling purposes.

Marking Plate and Marking Film Size

LB Series (flush bezel / standard bezel)

Lens Round Square Rectangular

Engraving

Area

12.0

ø13.7

Antirotation edge

Engraving

Area

… 12.0

… 13.7

Engraving

Area

18.0

19.7×13.7

• Engraving must be made on the engraving area within 0.5 mm deep.

• The marking plate is made of white acrylic resin.

11.8

… 13.6

• Film thickness: 0.1 mm per film

• Marking film is not included.

• Recommended marking film: Polyester film

19.6

B-133 www.apem-idec.eu

LB/LBW Series

Instructions

LBW Series

Lens Round Flush Square Round Extended

Replacing the LED Unit

The LED unit can be replaced without tools by pulling out the lens unit from the contact block.

Engraving

Area

16.4

ø17

Antirotation edge

Engraving

Area

16.4

18.4

• Engraving thickness: 0.5 mm max.

• The marking plate is made of white acrylic resin.

Engraving

Area

5.15 0.85

5.15 0.85

14.0

Engraving

Area

Antirotation edge

ø15.8

14.0

Antirotation edge

ø15.8

14.0

16.4

• Film thickness: 0.1 mm per 2 films or 0.2 mm per film.

• Marking film is not included.

• Recommended marking film: Polyester film

LBW Series (ring-illuminated model)

Lens Round (Note) Square

14.0

ø16 max.

 18.4

• Film thickness: 0.1 mm max.

Note: Use a film with adhesive and attach on the light shield sheet. Make sure that the marking film is properly installed and does not protrude from the edge of light shield sheet.

Ring Illuminated Model Lens Holder

Light shield sheet

Insertion Order of Marking Plate and Film

LB/LBW Series Round

Engraged

Area

Contact Block LED Unit

Orientation of the LED unit

Insert the LED unit into the contact block with the TOP markings on the contact block and LED unit in the same orientation.

TOP TOP

APEM

Switches &

Pilot Lights

Control Boxes

Emergency

Stop Switches

Enabling

Switches

Safety Products

Explosion Proof

Terminal Blocks

Relays & Sockets

Circuit

Protectors

Power Supplies

LED Illumination

Notes on replacing the LED Unit

When replacing the LED unit, make sure that static electricity is not applied.

Make sure that the LB/LBW series has cooled down before replacing the LED unit. To avoid burn injuries, be careful not to touch the unit while it is still hot.

Controllers

Operator

Interfaces

Sensors

AUTO-ID

Notes on Using Quick Connect Terminals

1) Use #110 tab quick connects, 0.5 mm-thick.

2) When connecting the terminals on the left and center, make sure that surfaces of the quick connects face each other. Otherwise, short-circuit may occur.

TOP TOP

Flush Silhouette

ø16

ø22

ø30

Miniature

Pilot Lights

Color Lens Film Marking Plate

LB/LBW Series Square/Rectangular

Engraged

Area

Lens Holder

Color Lens

Note: Film is not included.

Film Marking Plate Lens Holder

The marking plate must be engraved on the specified side as shown above. Pay attention to the orientation of the marking plate. When inserting a film, make sure to insert between the color lens and marking plate.

Note: Marking plate is not supplied with ring-illuminated model.

Correct Incorrect

3) Apply only horizontal force against the panel to the tab. The switch may be damaged if a force other than a horizontal force is applied.

CW

LW-F

LB

LBW

UP

Flush Bezel www.apem-idec.eu

B-134

LB/LBW Series

Instructions

APEM

Switches &

Pilot Lights

Control Boxes

Emergency

Stop Switches

Enabling

Switches

Safety Products

Explosion Proof

Terminal Blocks

Relays & Sockets

Circuit

Protectors

Power Supplies

Installing the Rubber Boot

When using in places where the switches are subjected to water splash or an excessive amount of dust, make sure to use the optional rubber boot.

As shown in the drawing below, ➀ remove the gasket from the operator, and ➁ attach the rubber boot from the front (button side).

Standard Bezel

For rectangular and square units, pull out the seals of the rubber boot and place them around the operator sleeve as shown below. Make sure that the seals are not twisted or tucked inside and that the gasket is removed, otherwise waterproof and dustproof characteristics are not ensured.

How to Install the Rubber Boot

Rectangular

Seals

Seals ➁

Mount Operator

Remove

LED Illumination

Rubber boot installed

Controllers

Operator

Interfaces

Sensors

Square

Gasket

Seals

AUTO-ID

Seals ➁

Mount Operator

Flush Bezel

Mount the rubber boot so that the protrusion at the bottom surface of the operator fits with the recess on the operator, placing the rubber boot all around the operator sleeve.

Make sure that the protrusion on the rubber boot and the recess on the operator is properly fitted, otherwise, the waterproof and dustproof characteristics are not ensured.

How to Install the Rubber Boot

➁ Mount

Protrusion

Recess

Remove

Good

Example

Bad

Example

Flush Silhouette

ø16

ø22

ø30

Miniature

Round

Pilot Lights

CW

LW-F

LB

LBW

UP

Flush Bezel

Mount

Gasket

Gasket

Remove

Operator

Remove

Rubber boot installed

Rubber boot installed

Gasket

Note: Install the rubber boot before mounting the unit to the panel.

Maintained Pushbuttons

Do not replace the buttons when the pushbutton is in the maintained position. Replacing the button in the maintained position may damage the internal mechanism. Also, do not remove the contact block with the button in the maintained position. The contact may not operate properly when the contact block is remounted. Make sure to push down fully when using the pushbuttons.

Pushbuttons and Illuminated Pushbuttons with

Switch Guard

Do not apply force to the switch guard when the switch guard is not attached to a panel. When opening the switch guard, do not open more than 180°. The hinge may break.

Selector Switches

When turning the operator or key, make sure that they are properly turned to each position.

Selector Switches with Key

Observe the following instructions to prevent malfunction or damage.

• Insert the key to the bottom of the key hole.

• Do not remove the key from any key retained position.

• Besides the standard key (key number 0H), six other key numbers are available. Use a key of the matching number with the key cylinder.

The standard key does not have a key number indication.

• Keys are available in two types.

Key numbers 0H (standard), 1H, and 2H are reversible keys which can be inserted in two ways.

Key numbers 3H, 4H, 5H, and 6H are non-reversible keys. Make sure of correct insertion direction.

B-135 www.apem-idec.eu

a) Panel thickness 2.8mm max.

w/rubber gasket

LB/LBW Series

Instructions

Countermeasures against Dim Lighting

Leakage currents through transistors or a contact protection circuit may cause the LED lamp to illuminate dimly even when the output is off.

When the LED lamp is illuminated by a transistor output, take the following measure.

Shunt Resistor

LED

Pilot

Light

Leakage Current Shunt Resistor Allotment Table (Recommended)

Leakage Current

Io

Shunt resistance R

Red (R), White (W) Green (G)

0.1 mA max.

Resistance Rated Power Resistance Rated Power

13kΩ 0.25W

18kΩ 0.25W

0.1 to 0.7 mA 2kΩ 0.25W

2.7kΩ 0.25W

Noise

LED elements deteriorate due to extraneous noise, resulting in

When such effects are anticipated, take a protection measure shown below. However, measures may differ according to operating environment and condition

Zener Diode

(Zener diode reference value)

Zener voltage: 4.3 to 4.7V

b) Panel thickness 2.8 to 3.2mm

(+) (–)

UP series are delicate products that may be damaged by static electricity Make sure to take measures to prevent static electricity.

Switch Guards

Opening/closing the Switch Guard

When opening/closing the switch guard while the switch guard is not installed on a panel, make sure to hold the hinge. Holding the base might result in damage. Also do not apply force on the guard in other than open/close directions, otherwise the hinge may be damaged.

Rubber Gasket when using LB9Z-K2 Switch Guard (remains open) for Round/Square Units

Choose to use or not to use the rubber gasket for the switch referring

IP40 with or without the rubber gasket.

• When the panel thickness is up to 2.8mm

Install the switch onto the switch guard with rubber gasket, and mount on the panel.

w/rubber gasket b) Panel thickness 2.8 to 3.2mm

• When the panel thickness is 2.8 to 3.2mm

Remove the rubber gasket from the switch and install the switch onto the switch guard, and mount on the panel (discard the rubber gasket).

w/o rubber gasket

APEM

Switches &

Pilot Lights

Control Boxes

Emergency

Stop Switches

Enabling

Switches

Safety Products

Explosion Proof

Terminal Blocks

Relays & Sockets

Circuit

Protectors

Power Supplies

LED Illumination

Controllers

Operator

Interfaces

Sensors

AUTO-ID c) Single board mounting

• Single board mounting

Remove the rubber gasket from the switch and install the switch onto the switch guard, and mount on the panel (discard the rubber gasket).

w/o rubber gasket

Flush Silhouette

ø16

ø22

ø30

Miniature

Pilot Lights

Base

Hinge

CW

LW-F

LB

LBW

UP

Flush Bezel b) Panel thickness 2.8 to 3.2mm

w/o rubber gasket c) Single board mounting w/o rubber gasket www.apem-idec.eu

B-136 c) Single board mounting w/o rubber gasket

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement