Unitech
HT580L Operation Guide
Version 1.0
Unitech Part Number: 400412 1
Overview
............................................................................................................................................................ 3
1.
SETTING .............................................................................................................. 4
1.1.
DATE & TIME .............................................................................................................................................. 4
1.2.
Device.............................................................................................................................................................. 5
1.2.1.
BACKLIGHT ........................................................................................................................................... 5
1.2.2.
SCANNER .............................................................................................................................................. 5
1.2.3.
AUTORUN.............................................................................................................................................. 6
1.2.4.
Memory ................................................................................................................................................... 6
1.3.
MODEM......................................................................................................................................................... 6
1.3.1.
BAR....................................................................................................................................................... 10
1.3.2.
PSWD – Password ............................................................................................................................. 11
1.3.3.
SYS – Perform Cold/Warm Start or Update F/W.................................................................................. 11
1.3.4.
DIAG - Diagnostics ............................................................................................................................... 12
2.
COMMUNICATION..............................................................................................13
2.1.
USB communication .................................................................................................................................... 13
2.2.
BlueTooth communication.......................................................................................................................... 13
2.3.
Communication program ........................................................................................................................ 15
2.4.
Modem communication ........................................................................................................................... 17
3.
TECHNICAL SPECIFICATION
....................................................................19
Model .................................................................................................................................................................... 19
HT580L ................................................................................................................................................................. 19
3.1.
Pin Assignment ......................................................................................................................................... 20
Unitech Part Number: 400412 2
Overview
HT580L operation guide will cover more detail on F/W setting and software development tool
APG580 (Application Generation for HT580L)
After power on HT580LL, it will show main menu as below
HT580L V1.15
1. SETTING
2. FORMCACHING
3. RUN APG580
There are 3 options – Setting , Formaching and Run APG580.
Unitech Part Number: 400412 3
1. Setting
Setting menu do 2 major functions – User mode setting and Supervisor setting. In HT580L User
Guide, it already explains user mode operation. This document will also repeat it again from below section.
Note : Due to no barcode scanning requirement on Setting menu, SCAN key will also be treated as ENTER key during Setting operation. So, user can use below 2 ways to select any
Setting item
Press MENU key to move cursor to target item and then press SCAN(or ENTER) key
Direct press item number (without combining with ENTER) to enter setting item
After pressing “1” key from main screen, there are four setting options which include the following:
1. DATE & TIME
2. DEVICE
3. MODEM
4. SUPERVISOR
1.1. DATE & TIME
Press “1” (or press “ MENU ” key to move cursor to item 1) to enter DATE & TIME category so that you are able to set the correct date and time. The page will appear as it is shown below:
YYYY-MM-DD
2000-01-08
HH-MM-SS
05:50:35
Press numeric keys to input correct date & time. Once complete, press [ENTER] to save the revised settings. To go back to previous menu, press [ ESC ].
Unitech Part Number: 400412 4
1.2. Device
Use MENU key to move cursor to one of item and then press ENTER (or SCAN key) or directly press
“1” ~ “3” to select target item:
1. BACKLIGHT
2. SCANNER
3. AUTORUN
4. MEMORY
1.2.1. BACKLIGHT
HT580L’s backlight can be automatically on after key pressed and it will automatically off after predefined period time if there is no more key pressed. Timeout period will be reset if any key is pressed.
In HT580L, timeout period can be set to 10/20/30 or 60 seconds. Or backlight can be set as always OFF or ALWAYS on.
To set up the backlight, press MENU to adjust the setting. There are below options for choice
Item Description
On 10 SECS Turn on backlight after key-pressing, and then automatically turn off after 10 seconds
On 20 SECS
On 30 SECS
Turn on backlight after key-pressing, and then automatically turn off after 20 seconds
Turn on backlight after key-pressing, and then automatically turn off after 30 seconds
On 60 SECS
Always
Off
Turn on backlight after key-pressing, and then automatically turn off after 60 seconds
Always turn on backlight
Always turn off backlight
BACKLIGHT selection : ON 10 SECS/ ON 20 SECS/ ON 30 SECS/ ON 60 SECS/ Always/ OFF
Selecting your preference and press [ENTER] to save the change. To go back to previous menu, press
[ ESC ].
1.2.2. SCANNER
SCANNER selection: ON NORMAL/ON FLASH/OFF.
Press [MENU] key to select your preference and press [ENTER] (or [SCAN] key) to save the changes. To go back to the previous menu, press [ ESC ].
Below are explanation for those 3 options
ON
NORMAL
Standard operation way (one trigger on scan), scanning beam will be emitted when press SCAN key and scanning will be off when releasing SCAN key. Scanning beam will be
ON FLASH also off when it successfully read barcode
Press SCAN (and then immediately), scanner will automatically continuously emit scanning beam and off scanning beam until Enter flash mode after press SCAN key
(and then release SCAN key). User can press SCAN key again to stop Flashing.
OFF Turn off scanner. Scanning beam will not be emitted after press SCNA key
Unitech Part Number: 400412 5
1.2.3. AUTORUN
AUTORUN is defined to automatically run pre-define FORMCACHING or APG580 program after power on. Or setup HT580L to back to previous running point before power off. There are below 4 options for choice.
Formcaching Always run Formcaching from beginning after power on
HT580L
APG580
RESUME
Always run APG580(EasyJob) from beginning after power on
HT580L
Back to previous running point before power off. This option is default setting.
Always warm-start after power on. It will back to start menu. OFF
1.2.4. Memory
To display total memory and free memory space.
1.3. MODEM
Unitech provide modem cradle as HT580L’s accessory. So, user can get data through modem if
HT580L is plug into modem cradle.
In general, system administrator need to setup host PC to automatically dial to modem cradle and then issue command from host to do data communication or remote control. For such configuration, it is necessary to setup modem to automatically pick phone when host call modem. So, it provides option
“ AUTO ANSWER ” to setup modem from HT580L.
User can also directly call to remote host PC from modem cradle via HT580L. So, it is necessary to setup remote PC’s phone number, and then dial out, and then hang up phone if user need to stop modem communication.
There are below 4 options on MODEM
1.PHONE NUMBER
2.AUTO ANSWER
3.DIAL OUT
4.HANG OUT
To setup remote modem’s phone number
Send ATS0=1 [enter] to modem cradle. So, modem cradle will automatically pickup phone after one ring tone. You will get error message if HT580L is not plugged into cradle or modem cradle is power off.
Dial out according “Phone number” setting. It will send
“ATDT” + phone number
Hang up phone (send “+++” and then “ATH”)
Unitech Part Number: 400412 6
Unitech Part Number: 400412 7
FormCaching Specification
DATA FIELD DEFINITION: maximum field number=8
Category Range Description
1. FIELD PROMPT Max.16 characters set field prompting
1-48 2. MIN/MAX
Field LENGTH
3. Field type set minimum field length and maximum field length numeric data (0~9) or alphanumeric data (20H~FCH)
4. DEVICE TYPE
1.NUMERIC
2.ALPHANUM
1.KEY ONLY
2.SCAN ONLY
3.BOTH input by keyboard only, bar code scanning only or both
DATA RECORD DEFINITION
Category Range Description
5. Between Field 1.Append Screen
2.Clear Screen
1. Append Screen: Prompt will be displayed on next line according previous cursor place. If cursor is already on the last line, it will scroll one line up.
2. Clear Screen: It will clear screen and then display
6. FIELD DELIMITER 1. , 2. ;
3.SPACE 4.TAB
5. FIXED LENGTH
7. RECORD
DELIMITER
Assign field delimiter, “Fixed Length” mean to store data according maxi length setting, it will automatically append spaces to end of field data if length of input data are less than maxi. length assign record delimiter
8. DATE STAMP
FIELD
9. TIME STAMP
FIELD
10. Trasn. Mode
1.CR
2.LF
3.CRLF
1.NONE
2.MMDD
3.YYYYMMDD
4.DDMMYY
5.YYYYMMDD
6.DDMMYYYY
1.NONE
2.HHMM
3.HHMMSS
4.SSMMHH
1. Batch assign date stamp and specify the format of date stamp assign time stamp and specify the format of time stamp
T
11. FIELD DELAY 0-6 specify time delay between each record input in second
When FormCaching is enabled, a data file named FORM.DAT will be created in the HT580L.
FORM.DAT stores the data as entered by the user after FormCaching is invoked. The HT580L will not allow the user to redefine the data fields in FormCaching once the FORM.DAT has been created. The file FORM.DAT must be deleted in order to implement any change in the configuration of FormCaching.
Running The Resident FormCaching Application Program
Enable the FormCaching, the HT580L built-in application can be ran by switching the portable terminal to the main menu of operation and selecting “ 2.FORMCACHING
”, select “2.FORMCACHING”. The
FormCaching application program will follow the setting (as previously defined by the user) as it displays prompts, requests input, and stores data in the FORM.DAT file. Pressing [ESC] key will abort the current record inputting action.
Unitech Part Number: 400412 8
HT580L FormCaching Defaults
The HT580L enables FormCaching by default, the following settings also apply:
DATA FIELD DEFINITION: field number=2
Category Setting
Field #1 FIELD PROMPT
DATA LENGTH
ITEM:
20
DATA TYPE
DEVICE TYPE
Field #2 FIELD PROMPT
DATA LENGTH
DATA TYPE
DEVICE TYPE
DATA RECORD DEFINITION
ALPHANUM
BOTH
QTY:
8
NUMERIC
KEY ONLY
Category Setting
FIELD DELIMITER
RECORD FELIMITER
,
CR
DATE STAMP FIELD
TIME STAMP FIELD
FIELD DELAY
NONE
NONE
1
Unitech Part Number: 400412 9
1.3.1. BAR
This option is use to configure individual symbologies for each barcode. After enter configuration menu, the LCD will display the BARCODE Setup as shown below.
< BARCODE SETUP>
CODE 39
ON
Press [ MENU ] key to toggle between settings. Press [ SCAN ] or [ ENTER ] key to set.
Setup decoding of HT580L supported bar code symbologies
Symbology Function
Code 39 Decoding
Option
ON/OFF
Default
ON
OFF
OFF
I 2 of 5
Code 32
Matrix 2 of 5
CHINA POST
Start/stop Character Send/No-send
Decoding ON/OFF
Check Digit
First digit
Last digit
Decoding
First digit
Last digit
Decoding
Industrial 2 of 5 Decoding
Check Digit
CHINA POST Decoding
Check Digit
Decoding
OFF/On&Not send/ON&Send
SEND/NOT SEND
SEND/NOT SEND
ON/OFF
SEND/NOT SEND
SEND/NOT SEND
ON/OFF
ON/OFF
Codabar Decoding ON/OFF
ON / ON&Not Send / ON&SEND
/ OFF
ON/OFF
ON / ON&Not Send / ON&SEND
/ OFF
ON/OFF
NO SEND
ON
OFF
SEND
SEND
ON
SEND
SEND
ON
OFF
ON
ON
OFF
ON
OFF
MOD
Check Digit
IDATA 2 of 5 Decoding
Check Digit
10/DOUBLE MOD 11+10
ON&Send / ON&NOT SEND
ON/OFF
ON / ON&Not Send / ON&SEND
/ OFF
OFF
SINGLE
MOD 10
OFF
OFF
OFF
CODE 11 Decoding
Check Digit
ON/OFF
ON / ON&Not Send / ON&SEND
OFF
OFF
EAN-13 Decoding
/ OFF
ON/OFF ON
ON/OFF OFF
ISBN
ON/OFF OFF
ISBN
Leading Send
Check Send
EAN-8 decoding ON/OFF ON
Leading digit
Check Digit
SEND/NOT SEND
SEND/NOT SEND
UPC-A decoding ON/OFF
SEND
SEND
ON
EXPEND to EAN-13 ON/OFF OFF
Unitech Part Number: 400412 10
Leading digit
Check Digit
SEND/NOT SEND
SEND/NOT SEND
UPC-E decoding ON/OFF
SEND
SEND
ON
ON
ON
CODE 93
Code 128
A
Leading digit
Check Digit decoding decoding
SEND/NOT SEND
SEND/NOT SEND
ON/OFF
ON/OFF
EAN128 CODE ID ON/OFF
EAN128 FUNC CH NOT SEND/SEND
TELPEN decoding
UK PLESSEY decoding
Check Digit
1.3.2. PSWD – Password
ON/OFF
ON/OFF
SEND/NOT SEND
Change Supervisor password – The default password is “ 580 ”
1.3.3. SYS – Perform Cold/Warm Start or Update F/W
SEND
SEND
OFF
ON
ON
OFF
NOT
SEND
ON
OFF
SEND
1. WARM START
2. COLD START
3. UPDATE F/W
4. UPDATE DEC
There are 4 options on this item – Warm Start, Cold Start, Update
F/W and Update Decoder
Warm Start : warm boot HT580L
Cold Start : All of data and setting will be set to system default
Update F/W : Update F/W version. You can get the latest F/W image from supplier, F/W will be compressed as ZIP file. There are 8 files after unzip it – bank0.bin ~ bank7.bin. You can use communication program to send those 8 files into HT580L and then execute this option to update F/W. Please refer to Section Communication to know more detail information for communication program.
Unitech Part Number: 400412 11
1.3.4. DIAG - Diagnostics
The HT580L has a built-in diagnostics program to test the terminal's hardware. The test routines are data destructive . Therefore, before running the diagnostic program, make sure you back up the data in the HT580L.
Note : When a H/W or S/W service has been made on the PT630, such as maintenance, repair or upgrade, it
is strongly recommended to run the diagnostic program.
1. VER 2. SCAN
At the Supervisor Mode menu:
3. LCD 4. COMM
1. Press 7 (7.DIAG), then LCD will display the diagnostic menu as
5. PWR 6.KEY shown on the left. Select 1-8 to run the desired diagnostic routine
7. RTC 8.MEM
1. VER : Get F/W version for HT580L and Decoder.
2. SCAN : test bar code input by scanning bar code labels. Press ESC key to return to the diagnostics menu.
3. LCD : Darken the dots of the LCD screen and cycle power to the LCD backlight to check
4. if the LCD functions OK
COMM : Connect to PC’s communication testing program to test USB/RS232 communication
5. PWR : Testing Battery power
6. KEY : Test every key response
7. RTC : Show Current time/date is displayed
8. MEM : Test RAM condition
Note : Please refer to Service manual for more detail information.
Unitech Part Number: 400412 12
2. Communication
2.1. USB communication
To connect HT580L to PC via USB, you need to install USB driver which will redirect data to virtual COM port. You can get USB driver from HT580L CD.
Window OS will prompt new device dialog box when PC is the first time to be connected to HT580L via USB. Please re-direct driver folder to Unitech’s USB driver folder and then follow its prompting to install driver.
Then you can check correct COM port number from Control Panet System
Hardware Device manager, then you can find correct COM number from “USB
Serial Port” under option “Connection Port(COM and LPT)”
In HT580L, you should change it default communication port to “RS232/USB” from
Setting Supervisor Comm Port
2.2. BlueTooth communication
To do BlueTooth communication, you should change HT580L’s port setting to
BlueTooth from Setting Supervisor Comm Port
In PC, you should connect Bluetooth dongles if there is no Bluetooth support. And
Bluetooth driver should be pre-install.
Then , you must follow up below steps on you rPC
1. Power on HT580L and then Run Bluetooth manager from PC
2. Click “New Connection” buttom
3. Select proper mode – Express Mode or Customer Mode. User can specify COM port number if select customer mode.
Unitech Part Number: 400412 13
4. Then it will search all of Bluetooth device within BT converge area and then list them down on the screen. You can find all of HT580Ls will be displayed as “UNITECH”.
Then you can click “Next” button
5. Then it will prompt user to enter PIN code, HT580L’s default PIN (Pass key) is “0580”, then you can find this HT580L is already on your Bluetooth list. Then click right mouse button to connect it.
6. You can also check the correct PORT number from “Detail”
PS. HT580L’s BT Device name is fixed on “UNITECH”, so you will see a lots of
“UNITECH” on Bluetooth Manager if you want to connect several HT580Ls to single PC.
And user can not identify which one is correct HT580L to map to list. So, it is suggested to power on one HT580L at a time when make connection and please note its MAC address from DETAIL.
Unitech Part Number: 400412 14
program
In Easy Job, it also bundle one communication program named “MultiEj”. You can directly run it from
HT580L EasyJob
Or it from HT580L Easy Job and then then select Tool Communication as below diagram
Then it will launch MultiEj program as below screen, You can directly
1. drag and drop files from PC folder to HT580L directory to execute download function
2. drag and drop files from HT580L directory to PC folder to execute upload function
3. directly select files on HT580L directory area and delete.
Unitech Part Number: 400412 15
Before using MultiEj to do communication, you should setup correct port number and communication parameter by chick Options icon on menu bar.
Then click “NEW” button to select a new COM port, then configure its proper communication parameter and click OK button to finish setting. Then you can select proper port from Connection
List Box
After select proper COM port, you will find icons of Date/Time , WarmStart and ColdStart changed from grey to color icon.
Download / Upload / Delete / Execute will also become color if you select click files on local file
area or remote files area
Unitech Part Number: 400412 16
communication
For HT580L, Unitech provide modem cradle to enable modem communication function between PC and
HT580L. So, user must connect phone line to cradle and HT580L still connect to cradle with RS232 interface.
There are 2 ways to do connection.
1. Calling from PC
2. Calling from Terminal
Call from PC
To call modem from PC, HT580L’s modem cradle should be set to automatically pick up external call.
So, you should put HT580L into cradle (cradle should be connect to power) and execute Setting
Modem and then select “AUTO ANSWER” to let HT580L send “ATS0=1” to modem board (inside cradle). Then, cradle can automatically pick up external calling after one ring tone. (After execute
“AUTO ANSWER”, it is not suggested to power off cradle, or “Auto Answer” function will be disappeared)
In PC, you can use MultiEj to do modem communication with HT580L, you can setup modem function from Options by check “Modem” check
Then setup to correct Initial command, dial number, and wait time.
Call from HT580L
Current, HT580L can support modem dial from F/W. We will provide modem function from EasyJob in the future.
In PC side, you can use Hyperterminal to setup modem Auto Answer. And please put HT580L into cradle and phone line should be connected to cradle. Then follow up below step
Setting Modem Phone to input correct phone number
5. Then execute Setting Modem Dial out to connect to remote
After end of communication, execute Setting Modem Hang to hang up phone.
Unitech Part Number: 400412 17
Unitech Part Number: 400412 18
3.
Technical Specification
Model HT580L
Dimensions 123mm x 55mm x 25mm
Weight 150g
Drop Specification
Display
1.2M free drop to concrete floor
128 x 64 pixel; 16x8 characters or 12x4 characters
Battery
Environmental Sealing
Operation Temperature
Storage Temperature
One 3.7V
IP42
0°C~50°C
730
-20°C ~70°C mAH Li-ion battery
Humidity
Electrostatic Discharge
(ESD)
Back-Lit Display
5% to 95% RH, ; not condensed
4 KV contact discharge
8 KV air discharge
Yes
Keypads 18 alphanumeric keys including one scan trigger
Operating System Proprietary ( C Language)
Memory 1 MB for main program & data storage
Application Development EZ Job
Battery Life Up to 8 hours
Symbologies UPC/EAN, Code 39, Interleave 2 of 5, CODABAR, MSI, Code
128, Code 93, Code 32,China Postal Code
Buzzer Yes, over 75 dB
One LED Reading – green color
Unitech Part Number: 400412 19
3.1. Pin Assignment
The HT580L communicate via the RS232 communication port located on the bottom of the unit. You can connect the unit via the communication cable to PC RS232 jack for data transfer or connect through cradle for communication.
Pin Name
1 US-POWER
2 GND
3 DC-IN
5 CTS
6 RTS
7 DSR
8 GND
9 DTR
10 TXD
11 RXD
Unitech Part Number: 400412 20
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter.
Unitech Part Number: 400412 21
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project