advertisement
R
ACK
M
OUNT
R
EPEATER
VXR-9000
O
PERATING
M
ANUAL
FCC ID: K6610443240
IC ID: 511B-10443240
VXR-9000 FM R
EPEATER
O
PERATING
M
ANUAL
VERTEX STANDARD CO., LTD.
4-8-8 Nakameguro, Meguro-Ku, Tokyo 153-8644, Japan
VERTEX STANDARD
US Headquarters
10900 Walker Street, Cypress, CA 90630, U.S.A.
YAESU EUROPE B.V.
P.O. Box 75525, 1118 ZN Schiphol, The Netherlands
YAESU UK LTD.
Unit 12, Sun Valley Business Park, Winnall Close
W inchester, Hampshire, SO23 0LB, U.K.
VERTEX STANDARD HK LTD.
Unit 5, 20/F., Seaview Centre, 139-141 Hoi Bun Road,
Kwun Tong, Kowloon, Hong Kong
Vertex Standard Co., Ltd.
FCC ID: K6610443240
IC ID: 511B-10443240
I
NTRODUCTION
The
VXR-9000
is commercial-grade 50-watt FM repeater designed to provide reliable two-way full-duplex communications over a wide range of environmental conditions.
Designed to mount in a standard 19-inch rack, the
VXR-9000
is crafted using the latest computer-aided design and manufacturing processes, to ensure a high level of reliability to users. Important channel frequency data is stored in
EEPROM, and is easily programmable by a Servicing Technician or Dealer using an IBM compatible personal computer and the
VPL-1
Programming Cable and
CE60
Software.
Please take a few minutes to read this manual carefully. The information presented here will allow you to derive maximum performance from your
VXR-9000
. After reading it, keep this manual handy for quick reference, in case questions arise later on.
Important Note: Internal service work, programming, and accessory installations should only be performed by your authorized Vertex Standard Dealer. Dangerous conditions and/or possibly illegal operation may result from improper setup, programming, or internal modifications.
S
AFETY
/W
ARNING INFORMATION
The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures with a separation distance of at least 100cm from all persons during normal operation and must not exceed an antenna gain of 0 dBd. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. The antenna(s) used with this device must satisfy the antenna co-location requirements of 47 C.F.R. 1.1307(b)(3).
N
OTICE
!
r Do not modify this repeater for any reason.
Refer service of this repeater to qualified technicians only.
r Should an obviously abnormal condition be observed, such as overheating, a burning smell, etc., turn the main power switch off, and disconnect the AC plug from the AC mains supply or wall outlet immediately.
r Do not place any combustible material near the repeater.
r Do not spray any liquid over the repeater.
r Ensure that the power and antenna connections are securely made, using cables with excess capacity for the power being utilized.
VXR-9000 FM R
EPEATER
O
PERATING
M
ANUAL
Vertex Standard Co., Ltd.
F
RONT
P
ANEL
C
ONTROLS
& C
ONNECTORS
• ‡ ˆ ‰ Š
FCC ID: K6610443240
IC ID: 511B-10443240
‚ ƒ „ … †
• POWER
(
O/I
) Switch
This is the main power switch for the repeater.
‚
Power Indicator (
MAIN
)
This LED glows green when the main power source is used.
ƒ
Power Indicator (
BACKUP
)
This LED glows red when the backup power source is used.
„ MIC
Jack
Connect the microphone plug to this jack. This jack is also used for writing and reading channel frequency or other configurations via the COM Port of the PC on which the clone editor (
CE60
) is running.
…
Programmable Function (
PF
) Key
Six pushbuttons on the front panel are programmable function (
PF
) keys, each with an orange indicator inside. Each key can be programmed with two functions, one for a “long” press and one for a
“momentary” press. The
PF
key functions may be customized, via programming by your VERTEX
STANDARD dealer, to meet your communications network requirements. Note that some functions may require the purchase of optional internal accessories. The possible PF key features and functions are explained on the pages to follow.
† VOL
Knob
This control knob adjusts the output level of the front speaker and external speaker jack on the back panel.
‡ TX
Indicator
This LED glows red when the repeater is transmitting.
ˆ
Numeric Display
This display consists of two 7-segment LEDs, indicating the channel number during normal operation. If an abnormal condition arises, an error code will be displayed:
D
ISPLAY
D
ESCRIPTION
01
P C
U L
H I
S C
L C
E 1
E 2
- 32 Channel Number
Clone Active
PLL Unlock
High temperature in PA Unit
Scan Active
Front Panel Keys are Locked
PTT key is Disabled
Cooling Fan is Disabled
E 5
E 7
Low Voltage in Backup Battery
PA Unit Abnormality
E3 , E4 , E6 , E9 Contact your Dealer
‰ BUSY
Indicator
This LED glows green when the receiving channel is busy.
Š
Speaker
The internal speaker is located here.
VXR-9000 FM R
EPEATER
O
PERATING
M
ANUAL
Vertex Standard Co., Ltd.
FCC ID: K6610443240
IC ID: 511B-10443240
P
ROGRAMMABLE
F
UNCTION
( PF ) K
EY
D
ETAILS
F
UNCTION
CH D
OWN
CH U
P
C
OMPANDER
CTCSS/DCS E NC
CTCSS/DCS D
EC
CW ID
T
WO
T
ONE
D
EC
CW ID S
IGNAL
CW M ESSAGE 1
CW M
ESSAGE
2
CW M
ESSAGE
3
CW M
ESSAGE
4
CW M
ESSAGE
5
CW M ESSAGE 6
CW M
ESSAGE
7
CW M
ESSAGE
8
DC P
OWER
S
AVE
E
NCRYPTION
E NCRYPTION C ODE
K
EY
L
OCK
L
OCAL
PTT
M
ONITOR
M
ONITOR
M
M ULTI T ONE
P
ANEL
I
NDICATOR
R
EMOTE
R
EPEAT
R
ESET
S CAN
S
QUELCH
T
EST
T
ONE
T
EST
T
ONE
M
TOT
T RANSMIT
TX P
OWER
M
ID
TX P
OWER
L
OW
PF-1 K
EY
P
RESS
P
RESS
& H
OLD
PF-2 K
EY
P
RESS
P
RESS
& H
OLD
CH D
OWN
Press (or Press and hold in for one second) the
PF
key assigned to “CH Down” to step to the next-lower operating channel.
PF-3 K
EY
P
RESS
P
RESS
& H
OLD
PF-4 K
EY
P
RESS
P
RESS
& H
OLD
CTCSS/DCS E
NC
PF-5 K
EY
P
RESS
P
RESS
& H
OLD
PF-6 K
EY
P
RESS
P
RESS
& H
OLD
Press (or Press and hold in for one second) the
PF
key assigned to “CTCSS/DCS Enc” to turn the CTCSS/DCS
Encoder “On” or “Off” (toggle).
CH U
P
Press (or Press and hold in for one second) the
PF
key assigned to “CH Up” to step to the next-higher operating channel.
C
OMPANDER
Press (or Press and hold in for one second) the
PF
key assigned to “Compander” to turn the Compander circuit “On” or “Off” (toggle). This function is only activated on the “Narrow Channel Spread” of the “ Base
Transceiver ” mode.
The Compander IC contains two variable gain circuits configured for compressing and expanding the dynamic range of the repeater’s transmitted and received audio signal. When you enable this function, the signal-tonoise ratio can be improved by reducing the transmitted audio dynamic range.
CTCSS/DCS D
EC
Press (or Press and hold in for one second) the
PF
key assigned to “CTCSS/DCS Dec” to turn the CTCSS/DCS
Decoder “On” or “Off” (toggle).
CW ID
Press (or Press and hold in for one second) the
PF
key assigned to “CW ID” to turn the CW Identifier feature
“On” or “Off” (toggle).
When the CW ID feature is set to “On,” your station’s callsign will be superimposed on the outbound signal, in Morse Code, at the beginning of every transmission.
Programming of the callsign is performed by your VER-
TEX STANDARD dealer.
VXR-9000 FM R
EPEATER
O
PERATING
M
ANUAL
Vertex Standard Co., Ltd.
FCC ID: K6610443240
IC ID: 511B-10443240
P
ROGRAMMABLE
F
UNCTION
( PF ) K
EY
D
ETAILS
T
WO
T
ONE
D
EC
Press (or Press and hold in for one second) the
PF
key assigned to “Two Tone Dec” to turn the 2-Tone Decoder
“On” or “Off” (toggle).
CW ID S
INGLE
Press (or Press and hold in for one second) the
PF
key assigned to “CW ID Single” to send the station callsign, via Morse Code, once. Programming of the callsign is performed by your VERTEX STANDARD dealer.
CW M
ESSAGE
1 - CW M
ESSAGE
8
Press (or press and hold in for one second) the
PF
key assigned to “CW Message 1 - 8” to send a pre-programmed Morse Code message on the transmitted signal. Programming of the message(s) is performed by your VERTEX STANDARD dealer.
DC P
OWER
S
AVE
Press (or Press and hold in for one second) the
PF
key assigned to “DC Power Save” to turn the DC Power
Save feature “On” or “Off” (toggle).
When DC Power Save feature is set to “ON,” activate the various power save feature (determined from your
VERTEX STANDARD dealer) while the repeater operates from the Backup Power Source.
E
NCRYPTION
Press (or Press and hold in for one second) the
PF
key assigned to “Encryption” to turn off the Optional Encryption Unit temporarily.
E
NCRYPTION
C
ODE
Press (or Press and hold in for one second) the
PF
key assigned to “Encryption Code” to select the Encryption
Code (determined from your VERTEX STANDARD dealer; require the
FVP-35
Rolling Code Encryption
Unit).
K
EY
L
OCK
Press (or Press and hold in for one second) the
PF
key assigned to “Key Lock” to lock the repeater’s front panel keys (except “Key Lock” key); this feature can be enabled to prevent repeater settings from being disturbed.
L
OCAL
PTT
Press (or Press and hold in for one second) the
PF
key assigned to “Local PTT” to enable (“On”) or disable
(“Off”) operation using a
PTT
switch connected to the front panel’s Microphone Jack.
M
ONITOR
Press (or Press and hold in for one second) the
PF
key assigned to “Monitor” to cancel CTCSS and DCS squelch decoding, so as to enable reception of signals present on the channel that do not contain a matching CTCSS tone or DCS code.
M
ONITOR
M
This function provides to “Monitor” to cancel CTCSS and DCS squelch decoding, so long as the
PF
key assigned to “Monitor M” is pressed and held in.
M
ULTI
T
ONE
Press (or Press and hold in for one second) the
PF
key assigned to “Multi Tone” to switch the Tone Table between “Main” and “Sub.”
P
ANEL
I
NDICATOR
Press (or Press and hold in for one second) the
PF
key assigned to “Panel Indicator” to turn the Front Panel’s
Illumination “On” or “Off” (toggle).
R
EMOTE
Press (or Press and hold in for one second) the
PF
key assigned to “Remote” to toggle the operating mode between the “ Remote ” mode and “ Local ” mode.
When the “ Remote ” mode is selected, the repeater operates according to the control instructions received from the external device (connected to the
ACC
jack on the rear panel). While in the “ Local ” mode, the repeater operates from the front panel’s
PF
keys.
R
EPEAT
Press (or Press and hold in for one second) the
PF
key assigned to “Repeat” to toggle the operating mode between the “ Repeater ” mode and “ Base Transceiver ” mode.
For normal operation, set this key to the “ Repeat ” mode.
When the “ Base Transceiver ” mode is selected, you can speak into the microphone to use this repeater as a transceiver.
R
ESET
Press (or Press and hold in for one second) the
PF
key assigned to “Reset” to reset (same function as the
POWER
switch “off” and “on”) the repeater.
VXR-9000 FM R
EPEATER
O
PERATING
M
ANUAL
Vertex Standard Co., Ltd.
FCC ID: K6610443240
IC ID: 511B-10443240
P
ROGRAMMABLE
F
UNCTION
( PF ) K
EY
D
ETAILS
S
CAN
Press (or Press and hold in for one second) the
PF
key assigned to “Scan” to start scanning. To stop scanning, press (or Press and hold in for one second) this key again.
The scanning feature is used to monitor multiple channels programmed into the repeater.
This function is only activated on the “ Base Transceiver ” mode.
S
QUELCH
Press (or Press and hold in for one second) the
PF
key assigned to “Squelch” to override the Squelch action
(CTCSS, DCS, and Noise Squelch), so as to hear any signal present on the operating channel.
T
EST
T
ONE
Press (or Press and hold in for one second) the
PF
key assigned to “Test Tone” to generate the Test Tone Signal, as programmed by your VERTEX STANDARD dealer.
Press (or Press and hold in for one second) this key again to stop the generation of the Test Tone. This is a toggle function.
Press (or Press and hold in for one second) this key while press and holding the PTT switch to transmit the Test
Tone Signal, as programmed by your VERTEX STAN-
DARD dealer.
T
EST
T
ONE
M
This function provides momentary generation of the above-referenced Test Tone signal, so long as the
PF
key assigned to “Test Tone M” is pressed and held in.
Press this key while press and holding the PTT switch to transmit the Test Tone Signal, as programmed by your VERTEX STANDARD dealer.
TOT
Press (or press and hold in one second) the
PF
key assigned to “TOT” to turn the Time-Out Timer feature
“On” or “Off” (toggle).
When the TOT feature is set to “On,” the repeater will return to the “Receive” mode automatically after a preset time of continuous transmission (determined via programming by your VERTEX STANDARD dealer).
T
RANSMIT
Press (or Press and hold in for one second) the
PF
key assigned to “Transmit” to enable (“On”) or disable
(“Off”) the transmission of the VXR-9000.
TX P
OWER
M
ID
Press (or Press and hold in one second) the
PF
key assigned to “TX Power Mid”to set the transmitter power to the “Mid” level.
Press (or press and hold in one second) this key again to return to the “Original” power level (determined via programming by your VERTEX STANDARD dealer).
This function is ignored on the channel which is programmed to the transmitter power to the “Mid” or
“Low” level by your VERTEX STANDARD dealer.
TX P
OWER
L
OW
Press (or Press and hold in one second) the
PF
key assigned to “TX Power Low”to set the transmitter power to the “Low” level.
Press (or press and hold in one second) this key again to return to “Original” power level (determined via programming by your VERTEX STANDARD dealer).
This function is ignored on the channel which is programmed to the transmitter power to the “Low” level by your VERTEX STANDARD dealer.
VXR-9000 FM R
EPEATER
O
PERATING
M
ANUAL
Vertex Standard Co., Ltd.
FCC ID: K6610443240
IC ID: 511B-10443240
R
EAR
P
ANEL
C
ONNECTORS
• ‚ ƒ „
BACKUP
B A C K U P
MAIN RX
TX
INPUT
DC 13.6V
EXT
… † ‡
ACC
GND
•
Backup Power Source Terminals
If available, a backup 13.6 Volt power source, such as a rechargeable battery, may be connected here.
When the Battery Charge switch (located on the PA
Unit) is set to “ON,” a “trickle” charge current is present here while the repeater is operating from the “Main Power Source.”
‚
Circuit Protection Fuse
Two 15-Amp blade fuses, for the “Main” and
“Backup” power sources, are installed here.
ƒ RX
Antenna Jack
This BNC-type coaxial jack accepts the receiver input signal, for connection to the receiving antenna, or the “RX” jack on the duplexer. The input impedance requirement is 50 Ohms.
„ TX
Antenna Jack
This N-type coaxial jack provides the transmitter output signal, for connection to the transmitting antenna, or the “TX” jack on the duplexer. The output impedance requirement is 50 Ohms.
…
Main Power Source Connector
The primary DC power source should be connected here. The power requirements are 13.6 V DC at 12
Amps, continuous duty.
†
External Speaker Jack
This 3.5-mm, 2-pin jack provides variable audio output for an external speaker. The audio output impedance at this jack is 4 to 16 Ohms, and the level varies according to the setting of the front panel's
VOL
knob.
‡
DSUB 25-pin Accessory Connector
This DB-25F connector allows the repeater to be remote-controlled by an external controller. Analog
I/O signals, such as TX Audio In, Discriminator
Output, RSSI, etc. are available. Moreover, the
VXR-
9000
provides eight ports that can be programmed for various input or output signals, or for control functions. Each port may be programmed as to its function, its status (input or output), and its logic
(for output ports only).
VXR-9000 FM R
EPEATER
O
PERATING
M
ANUAL
Vertex Standard Co., Ltd.
The
VXR-9000
repeater is provided with a 25-pin DB-
25F female connector for interconnections to accessories.Use a DB-25M 25-pin male connector to connect accessories to the repeater. The pins on the accessory connector are explained in detail as follows:
Pin 1
: GND
Chassis ground for all logic levels and power supply return.
Pin 2
: +13.6 V
[P
OWER
S
UPPLY
]
This pin provides 13.6 Volts, 2.0 A, DC from the repeater supply. There is a internal 3 A fuse to prevent damage to the repeater.
Pin 3
: TX AF IN
[ A
NALOG
T
RANSMITTER
I
NPUT
] ( V
OICE
B
AND
: 300 ~ 3,000 H
Z
)
This pin is audio input. Input impedance is 600 Ohms.
This audio is injected before the splatter filter stage, so excess signal input levels are clipped.
Use shielded cable to connect to this pin, and connect the shield to GND .
Pin 4
: TONE IN
[ T
RANSMITTER
I
NPUT
] ( S
UB
-
AUDIBLE
B
AND
: 5 ~ 250 H
Z
)
This pin is sub-audiable tone input. The input impedance is 600 Ohms, and has a flat response characteristic
(repeater deviation is constant for a given signal level over the frequency range of 5 ~ 250 Hz). Injecting too high a voltage here causes over-deviation of CTCSS or
DCS, degrading performance.
Use shielded cable to connect to this pin, connecting the shield to GND .
FCC ID: K6610443240
IC ID: 511B-10443240
DB-25 C
ONNECTOR
P
ORT
Pin 5
: TX ATT
This output is intended for controlling an external coaxial switching relay. It is an open drain output which can sink approx. 1.5 A when active. The delay time which is between the repeater cause to transmit mode and this port switches to ground can be programmed by your VERTEX STANDARD dealer.
Pin 6
: DISC OUT
[ A
NALOG
O
UTPUT
] ( W
IDE
-B
AND
: 0 ~ 3,000 H
Z
)
Received signals with full system deviation produce
350 mVrms audio at this pin. The output impedance is
600 Ohm, and is extracted before the de-emphasis and squelch circuitry. Use shielded cable to connect to this pin, and connect the shield to GND .
Pin 7
: N.C.
No connection.
Pin 8
: RSSI
[A
NALOG
O
UTPUT
]
A DC voltage proportional to the strength of the signal currently being received ( R eceiver S ignal S trength I ndicator) is provided on this pin. This low impedance output is generated by the receiver IF sub-system and buffered by an internal op-amp. Typical voltages are graphed as follows:
(DC V)
2.5
2.0
1.5
1.0
0.5
0
–60 –70 –80 –90 –100
Input Signal Level
–110 –120 (dBm)
Pin 9
: COAX. SW
[ L
OGIC
O
UTPUT
( A
CTIVE
L
OW
)]
This output is intended for controlling an external coaxial switching relay. It is an open drain output which can sink approx. 1.5 A when active. This signal only switches if the repeater has been programmed for “ SIM-
PLEX ” mode. If programmed for “ DUPLEX, ” the signal remains open (high impedance) at all time.
DB-25 P
IN
N
UMBERING
VXR-9000 FM R
EPEATER
O
PERATING
M
ANUAL
Vertex Standard Co., Ltd.
FCC ID: K6610443240
IC ID: 511B-10443240
DB-25 C
ONNECTOR
P
ORT
Pin 10 , 13 , 15 , 16 , 17 , 18 , 19 , 21
:
P
ROGRAMMABLE
I/O “0” ~ ”7”
The
VXR-9000
provides eight ports (PIO) that can be programmed for various input or output signals, or for control functions. Each port may be programmed as to its function, its status
(input or output), and its logic (for output ports only).
Pin I/O Port
10
13
15
16
17
18
19
21
6
7
4
3
2
1
0
5
Pin 11
: NSQ DET
This is an open-collector, active-low output capable of sinking about 10 mA. It indicates that the receiver squelch is open. If the squelch control is properly set, this indicates a carrier on the receiver channel.
Pin 12
: EXT PTT
This input is internally pulled up to 5 VDC. When pulled low by an external device, it keys the repeater transmitter while the repeater is operating in the “ Remote ” mode. Avoid voltage in excess of 5 V on this pin, or internal damage to the microprocessor on the repeater
CNTL Unit may result.
Pin 14 , 20
: GND
Chassis ground for all logic levels and power supply return.
Pin 22
: RXD LOW
[ A
NALOG
O
UTPUT FOR
DATA C
OMMUNICATIONS
]
( 300 ~ 3,000 Hz )
This pin is an output for low speed receiving data signals (typically 1200 bps), with the data being extracted after the de-emphasis and low pass filter stages.
Pin 23
: RXD HIGH
[ D
IGITAL
O
UTPUT FOR
DATA C
OMMUNICATIONS
]
( Max.: 5 kHz )
This pin is an output for high speed receiving data signals (typically 9600 bps), with the data being extracted immediately after the discriminator (prior to any deemphasis).
Pin 24
: TXD LOW
[ A
NALOG
I
NPUT FOR
DATA C
OMMUNICATIONS
]
( 300 ~ 3,000 Hz )
This pin is intended to be used as a low speed data signal input to the repeater (typically 1200 bps). This digital data signal is injected before the transmitter preemphasis and limiting stages, so excess signal input levels are clipped.
Pin 25
: TXD HIGH
[ D
IGITAL
I
NPUT FOR THE
DATA C
OMMUNICATIONS
]
( 0 ~ 5 kHz )
This pin is intended to be used as a high speed digital data signal input to the repeater (typically 9600 bps).
This digital data signal is injected after the transmitter splatter filter stage.
VXR-9000 FM R
EPEATER
O
PERATING
M
ANUAL
Vertex Standard Co., Ltd.
Antenna Considerations
Repeater operation requires two antennas, one for receiving and one for transmitting, so that the receiving antenna does not absorb energy from the transmitting antenna. There are a number of ways to do this, depending on the TX/RX frequency separation, and on the locations available for antenna mounting.
Regardless of the above choice, it is of paramount importance that the antenna(s) be mounted as high and in the clear as possible, preferably within line-of-sight to all repeater users. Furthermore, losses in the feedline(s) must be minimized, so the feedline(s) should be high quality, and as short as possible. If a long feedline is necessary, use coaxial “hardline” cable to reduce losses.
Repeater antennas should have an impedance of 50
W at the operating frequency. When separate receive and transmit antennas are used, high-Q narrow-band types may serve to minimize interaction.
NEVER TRANSMIT WITHOUT HAVING A
TRANSMIT ANTENNA CONNECTED TO THE
TX ANTENNA JACK OF THE REPEATER.
FCC ID: K6610443240
IC ID: 511B-10443240
I
NSTALLATION
Equipment Location
The
VXR-9000
must be installed in a 19-inch Mounting
Rack, which will allow for free air flow around the heat sink on the rear apron at all times. In warm climates, the repeater should not be sealed in a small, closed room without air conditioning.
While the operating temperature range of the
VXR-9000 is quite broad, the best location is one in which the air temperature does not approach the extremes of the specified range, and one that does not change rapidly.
Protect the
VXR-9000
(Mounting Rack) from wind and rain, and extremes in temperature or humidity that may shorten the useful life of the equipment. Try to locate the
VXR-9000
(Mounting Rack) in an environment that is also comfortable for service personnel, if possible.
VXR-9000 FM R
EPEATER
O
PERATING
M
ANUAL
Vertex Standard Co., Ltd.
FCC ID: K6610443240
IC ID: 511B-10443240
I
NSTALLATION
Power Supply
Operation of the
VXR-9000
requires a power source capable of providing at least 12 Amps continuously at
13.6 Volts DC. The
FP-1023
(23 A) and
FP-1030A
(30 A)
AC Power Supplies are available from your Vertex Standard dealer to satisfy these requirements. Other wellregulated power supplies may be used, as well, if they meet the above voltage and current specifications.
Use the DC power cable supplied with your repeater for making power connections to the power supply.
Connect the RED power cable lead to the POSITIVE (+) power supply terminal, and connect the BLACK power cable lead to the NEGATIVE (–) power supply terminal.
Backup Power Supply
For uninterrupted operation during power failures, a
12 volt rechargeable type battery (55-Ah or more recommended) may be connected to the
BACKUP
terminal posts on the rear panel. When the Battery Charge switch is set to “ON,” a slight charging current will maintain battery charge while the repeater is operating from the “Main Power Source.” In the event of an
“Main Power Source” outage, the automatic power control circuit will automatically switch the repeater to the backup battery, and operation will not be interrupted.
After prolonged operation from the battery, it should be disconnected from the repeater and recharged separately before re-connecting, as the trickle charge is not sufficient for recharging a completely discharged battery.
Never reapply “Main” power to the repeater with a discharged battery connected, as the DC startup current can damage the repeater and battery.
While operating from a backup battery, the repeater requires approximately 7 amperes at 12 Volts during transmit.
Never short the “Backup Power Sorce” Terminals, when the Battery Charge switch (located on the PA
Unit) is set to “ON.”
Backup Battery
(12 V, 55 Ah)
BACKUP
B A C K U P MAIN
RX
INPUT
DC 13.6V
EXT
ACC
TX
GND
Supplied DC Power Code
T
YPICALLY
S
ETUP
VXR-9000 FM R
EPEATER
O
PERATING
M
ANUAL
Vertex Standard Co., Ltd.
Supplied Accessories
DC Power Cord (T9023449) ......................................... 1
15-A Blade Fuse (Q0000075) ........................................ 1
Knob Cap (RA0506900) ................................................ 1
Operating Manual ........................................................ 1
FCC ID: K6610443240
IC ID: 511B-10443240
A
CCESSORIS
& O
PTION
Optional Accessories
FIF-9
Inline Interface Box
FVP-25
Encryption Unit
FVP-35
Rolling Code Encryption Unit
MD-11
A8J
Desktop Microphone
MH-27
A8J
Hand Microphone
VXR-9000 FM R
EPEATER
O
PERATING
M
ANUAL
Vertex Standard Co., Ltd.
FCC ID: K6610443240
IC ID: 511B-10443240
Part 15.21: Changes or modifications to this device not expressly approved by Vertex Standard could void the user’s authorization to operate this device.
VXR-9000 FM R
EPEATER
O
PERATING
M
ANUAL
Vertex Standard Co., Ltd.
FCC ID: K6610443240
IC ID: 511B-10443240
VXR-9000 FM R
EPEATER
O
PERATING
M
ANUAL
Vertex Standard Co., Ltd.
advertisement