Soyal AR-721H Manual
Add to My manuals8 Pages
Soyal AR-721H, a cutting-edge access control system, offers unparalleled security and convenience for your premises. With the ability to connect to a variety of card readers, including 125kHz and 13.56MHz, this device provides flexible access control solutions. The AR-721H also features an illuminated touch panel, making it easy to operate even in low-light conditions.
advertisement
SOYAL
ACCESS CONTROL SYSTEM
® AR-321H/AR-331H/
AR-721H/AR-725H/AR-757H
Contents
AR-321H [Touch-panel Metal Housing]
1 Product 2 User Guide 3 Terminal Cables 4 Tools 5 Water proof Strip
V110412
P7 d x2
P1 P2 P3 P4
AR-331H [Touch-panel Metal Housing]/ AR-331H-S [Metal Housing]
1 Product 2 Optional 3 User Guide
[Optional] or
AR-721RB
Digital Relay or
WG keyboard
AR-331H-S
AR-821RB
Original Relay AR-331H
AR-721H
1 Product 2 User Guide 3 Terminal Cables
4 Terminal Cables
P8
※ Must to purchase relay
5 Tools c x2 g x1 h x1
Protection Plug
4 Tools f x2
P1 P2 P3 P4
AR-725H [Illuminated Touch-panel]
AR-725H-M
1 Products 2 User Guide 3 Terminal Cables 4 Tools
A.
AR-725H
1 Products
A1.
AR-725X
1 Products
A2.
AR-757H
1 Product
B.
A3.
Parts Description
a.
Button Head Pozidriv
Tapping Screw: M3x10 e.
E.
B.
C.
F.
C.
D.
2 User Guide
G.
b.
Button Head Pozidriv
Slotting Screw: 2.5x10
f.
P1 P2
P3
3 Terminal Cables
P4 c x2 e x1
2 User Guide 4 Tools f x2
P1 P2
P3 P4
2 Tools a x2 b x2 c x2 e x1
H.
D.
3 Terminal Cables 4 Tools f x2
P1 P2 P3 P4 P6 c.
Flat Head Cap Philips
Tapping Screw: 4x19.1
g.
Security Torx Screw: M3x10 d.
h.
Flat Head Cap Philips
Tapping Screw: 4x38
Security Torx Wrenches
Installation
AR-321H
3
AR-331H
4
1
2
3
2
1
AR-721H
Access Controller
Touch-panel Metal Housing / Illuminated Touch-panel V110412
Pull the cables from the square hole of the mounting plate.
Use a screwdriver to screw the mounting plate onto the wall.
Attach the water proof strip to the body, then connect the terminal cables to the body and attach the body to the mounting plate.
Use the Allen key and screws (accessories supplied) to assemble the body onto the mounting plate.
Turn on the power, and LED will light and beep will sound.
4 5
To cut tamper-resistant column and make it fit the appropriate height for actual installation.
First, take off the metal casing then screw the controller on the wall.
Second, put the metal casing back and lock it with security screw.
Finally, put the Protection plug into the hole.
Turn on the power, and LED will light and beep will sound.
4
AR-725H
AR-725H-M
2 c.
1
C.
A.
3
B.
4
A.
AR-725H
1
F.
5
B.
A1.
E.
3 e.
5
C.
A.
B.
6
A.
D.
8 d.
F.
4
2
7
C.
Pull the cables from the square access hole of the mounting plate C .
Use a screwdriver to screw the metal plate C onto the wall.
Take off the plastic mounting plate B from the body A , and pull the cables through the access hole of C and B , then connect to the body A .
Assemble plate B with the body A , and embed the water proof strip D onto the plastic side frame.
Assemble the body A onto the mounting plate C with the Allen key and screws (accessories supplied).
Turn on the power and LED will light and beep will sound.
Use a screwdriver to screw the base F onto the wall.
Attach the water proof gasket to the body A1 , and pull the cables from the square hole of the base F, and connect to the body A1 .
Assemble the body A1 with the base F .
Screw A1 and F tight with the Allen key and screws (accessories supplied).
Turn on the power and LED will light and beep will sound.
AR-725X
A1.
1
A3.
G.
AR-757H
2 b.
e.
3
A2.
H.
A1.+A3.
4
D.
a.
5
Put on G , and attach A1 onto the plastic plate A3 , and screw it with the Allen key and screws (accessories supplied).
Put the ring O on the metal frame, and put them together onto the reader A1 + A3 , and screw them and buckle up the 4 buckles on the back.
Embed the water proof strip D onto the frame side of the base.
Following by the install process of AR-725H-M.
4
Pull the cables from the square hole of the mounting plate.
Use a screwdriver to screw the base onto the wall.
Connect the terminal cables to the body and attach the body to the mounting plate.
Assemble the covers with the Allen key and screws (accessories supplied).
Turn on the power and LED will light and beep will sound.
SOYAL
ACCESS CONTROL SYSTEM
® AR-321H/AR-331H/
AR-721H/AR-725H/AR-757H
V110412
Notice
1.Tubing: The communication wires and power line should NOT be bound in the same conduit or tubing.
2.Wire selection:
3.Power supply:
Use AWG 22-24 Shielded Twist Pair to avoid star wiring.
Don’t equip controller and lock with the same power supply. The power for controller may be unstable when the lock is activating, that may make the controller malfunction.
The standard installation: Door relay and lock use the same power supply, and controller use independent power supply.
Connector Table
125kHz
13.56MHz
AR-331H
125kHz
13.56MHz
AR-721H
125kHz
P3
P2
P3
P7
10 9 8 7 6 5 4 3 2 1
P1
P4
P1
P5
P2
3
4
1
2
5
P8
13.56MHz
P2
P1
Cable:
P1
Wire Application
Lock Relay
Common-COM-Point
Door contact
Exit Switch
Alarm Relay
Power
6
7
4
5
8
Pin
1
2
3
Color
Blue White
Purple White
White
Orange
Purple
Gray
Thick Red
Thick Black
Description
(N.O.) DC24V1Amp
(N.C.) DC24V1Amp
(COM) DC24V1Amp
Negative Trigger Input
Negative Trigger Input
Low output; Max 12V/100mA (Open Collector)
DC Power 12V
DC Power 0V
Cable:
P2
Wire Application
Wiegand
Beeper
LED
Pin
1
2
3
4
5
Color
Thin Blue
Thin Green
Pink
Brown
Yellow
Description
Wiegand DAT:1 Input
Wiegand DAT:0 Input
Beeper Output 5V/100mA, Low
LED Green Output 5V/20mA, Max
LED Red Output 5V/20mA, Max
Cable:
P3
Wire Application
Networking
Module
Pin
1
2
Color
Thick Green
Thick Blue
Description
RS-485(B-)
RS-485(A+)
Cable:
P4
Contact Rating: 1A 125VAC/24VDC
Wire Application
Tamper Switch
Pin
1
2
3
Color
Red
Orange
Yellow
Description
N.C.
COM
N.O.
※ After S/N: 0706-XXXXXX
P4
AR-725H
125kHz
P2 P3
P5
P4
13.56MHz
P5
P5
P2
P3
Cable:
P5
(Optional)
Wire Application
3-PIN Connector
Pin
1
2
3
Color
Black
White
Purple
Description
GND.
Duress
Arming/ Security trigger signal
AR-757H
125kHz Main Board
P3
P4
P2
P4
P1
P6
P5
I/O Board
P1
P4
13.56MHz
P3
P2
P4
P1
P3
Main Board
P6
I/O Board
P1
Connectors Comparison
AR-321H
AR-331H
AR-721H
AR-725H
AR-757H
P1 P2 P3 P4
P7 P8
P1 P2 P3 P4
P1 P2 P3 P4
(
(
(
P1 P2 P3 P4 P6
Optional
Optional
Optional
)
)
)
Cable:
P6
Wire Application
Door bell
Arming
Duress
LED indicator
Pin
1
2
3
4
Color
Brown White
Red White
Yellow White
Green White
Description
BE Output
AR Output/ Security trigger signal Output
DU Output/ TTL out
Hi input/ Green light brighten
Cable:
Power
P7
Exit Switch
Lock Relay
Alarm Relay
Door contact
(Directly connected at the Access controller)
Wire Application
Networking Module
Networking Module
Tamper Switch
Pin
1
2
3
4
5
6
7
8
9
10
Color
Black
Red
Purple
Green
White
Blue
Yellow
Brown
Gray
Orange
Description
DC Power 0V
DC Power 12V
Negative Trigger Input
RS-485(B-)
Low output; Max 12V/100mA (Open Collector)/
Security trigger signal Output
RS-485(A+)
N.O.
COM
Low output; Max 12V/100mA (Open Collector)
Negative Trigger Input
Cable:
Beeper
Wiegand
P8 (for external WG Reader)
Wire Application
LED
Pin
1
2
3
4
5
Color
Brown
Yellow
White
Blue
Green
Description
LED Green Output 5V/20mA, Max
LED Red Output 5V/20mA, Max
Beeper Output 5V/100mA, Low
Wiegand DAT:1 Input
Wiegand DAT:0 Input
Access Controller
Touch-panel Metal Housing / Illuminated Touch-panel V110412
Wiring Diagram
Connect to Magnet Lock or Electric Bolt
12V
GND or
12V
GND
Electric Bolt Magnet Lock
Controller
POWER
12VDC
Connect to Reader
N.C.
COM
PB
12V
GND
P1
3
4
1
2
5
6
7
8
12V
GND
N.O.
POWER
12VDC
EXIT
Request To Exit
Reader
Connect to Electric Strike
12V
GND
Electric Strike
N.O.
COM
PB
12V
GND
P1
5
6
7
8
1
2
3
4
Controller
POWER
12VDC
12V
GND
Connect to Door Sensor
12V
POWER
12VDC
GND
WG 1
WG 0
BZ
GLED
RLED
12V
GND
POWER
12VDC
GND
12V
Controller
3
4
1
2
5
P2
WG 1
WG 0
BZ
GLED
RLED
P1
3
4
1
2
5
6
7
8
12V
GND
Door Contact
ALM
12V
GND
P1
5
6
7
8
1
2
3
4
Controller
POWER
12VDC
12V
GND
Connect to Networking
Converter
A+
B-
Strengthen security with AR-721RB
12V
GND
12V
GND
POWER
12VDC
Electric Bolt
P5
1 2 3
ARM
12V
GND
3
4
5
1
2
6
7
8
P1
N.C.
N.O.
COM
CTL
12V
GND
PB
AR-721RB
N.O.
Controller
EXIT
POWER
12VDC
12V
GND
Request To Exit
※ 1.Enable the security trigger signal: Please refer to the 34 DDD
2.Disable the door open button input. (Please refer to the
20 DDD of function default value.)
Connect to Access Control for
P7
Lock
PB
12V
GND
7
6
5
4
10
9
8
3
2
1
POWER
12VDC
Request To Exit
N.O.
12V
GND
P7
AR-331H
Electric Bolt
Relay Outpot Module
EXIT
N.C.
N.O.
COM
CTL
12V
POWER
12VDC
If use the AR-721RB, please refer to the top of the wiring diagram.
Node ID 001
AR-716E
Host
CH1
CH2
B-
A+
B-
A+
B-
A+
Controller
Node ID 254
P3
B-
A+
1
2
Connect to arming tools for
Door Contact
P7
AR-331H
Door
Contact
ALM
COM
N.O.
P7
12V
GND
6
5
4
3
2
1
8
7
10
9
N.C.
POWER
12VDC
12V
GND
12V
GND
N.C.
N.O.
COM
CTL
12V
Relay Outpot Module
N.C.
Node 1
P3
B-
A+
1
2
Controller
Controller
P3
B-
A+
1
2
Node 9
N.C.
N.O.
COM
CTL
12V
12V
CTL
COM
N.O.
N.C.
N.O.
POWER
12VDC
Alarm
EXIT
Request To Exit
Door Contact
GND
12V
POWER
12VDC
Node 8
P3
B-
A+
1
2
Controller
Controller
P3
B-
A+
1
2
Node 16
Alarm
Alarm Relay
Tamper Relay
Tamper Alarm
SOYAL
ACCESS CONTROL SYSTEM
® AR-321H/AR-331H/
AR-721H/AR-725H/AR-757H
V110412
Connect to Reader for
Reader
GLED
RLED
BZ
WG 1
WG 0
GND
12V
P8
AR-331H
P8
1
2
3
4
5
10
9
8
7
6
5
4
3
2
1
P7
12V
GND
Connect to Networking for
POWER
12VDC
12V
GND
P7
A+
B-
6
5
4
3
10
9
8
7
2
1
P7
A+
B-
Converter
B-
A+
B-
A+
B-
A+
Host
CH1
CH2
AR-716E
POWER
12VDC
GND
12V
AR-331H
External WG keyboard
※ If you want to program system on AR-331H-S directly, please order WG keyboard then install it according to the following pattern.
1
2
3
Remove the Protection plug that in the bottom right.
( ※ Do not lose protection plug or it will affect the protection level.)
WG Keyboard cable will be connected to the pin board.
WG Keyboard connected to the controller from the bottom right of the hole.
When you finish programming system, please put protection plug back to the controller.
Adding and Deleting Tag
Mode4/Mode8
Add Single Tag or Random tags
Input 123456 (or Master Code) → 19 UUUUU 00001 → Present the tag(s) with Controller (single tag or random numbered cards one by one) → Done
[e.g.] 2 readom cards with user addresses No. 100 and No. 101:
Access programming mode → 19 00100 00001 → Present the tags one by one → Done
Add the Sequential tags
Input 123456 (or Master Code) → 19 UUUUU QQQQQ → Present the tags (Present the tag with the lowest number first.) → OK
[e.g.] User Address NO.101 to NO.120 have 20 pcs of sequential tags:(62312~62332) :
Access programming mode → 19 00101 00120 → Close Tag into RF Area (only use the tag NO.62312
) → OK
Delete a Single Tag
Input 123456 (or Master Code) → 10 SSSSS EEEEE
[e.g.] Delete User Address: 00058
Access programming mode → 10 00058 00058
Tag Information
Delete a batch of Tags
Input 123456 (or Master Code) → 10 SSSSS EEEEE
[e.g.] Delete User Address: 00101~00245
Access programming mode → 10 00101 00245
CARD CODE
SITE CODE
CARD CODE
SITE CODE
Delete All Tags
Input 123456 (or Master Code) → 29 29
Mode6
※ At this mode, User Address = Card Code
Add Tags
Input 123456 (or Master Code) → 11 SSSSS EEEEE → OK
[e.g.] Add User Address: 00100~01254
Access programming mode → 11 00100 01254 → OK
Delete Tags
Input 123456 (or Master Code) → 10 SSSSS (or )EEEEE → OK
[e.g.] Delete a tag with card code 62362
Access programming mode → 10 62362 62362 → OK
Delete All Tags
Input 123456 (or Master Code) → 29 29
Operation process
A. Enter/ Exit Program Mode
Enter the program mode
Input 123456 or PPPPPP
[e.g.] The Default Value= 123456, if already changed the Master Code= 876112, input 876112 → program mode accessed
Exit the program mode
Input
Access Controller
Touch-panel Metal Housing / Illuminated Touch-panel V110412
Master Code modification
Access programming mode → 09 PPPPPPRRRRRR [Input the 6-digit new master code twice.]
[e.g.] Set the Master code to be 876112, input 123456 → 09 876112876112
B. Chang the Node ID of Controller
Access programming mode → 00 NNN [Node ID: 001~254]
C.Set up M4/M6/M8
Access programming mode → 04 N [N=4/6/8]
D. Set up the password
M4/M8: Individual pass code
Card or PIN: Access programming mode → 12 UUUUU PPPP [e.g. User address: 00001 and pass code: 1234, input 12 00001 1234 ]
Card and PIN: Access programming mode → 13 UUUUU PPPP [e.g. User address: 00001 and pass code: 1234, input 13 00001 1234 ]
M6: Public pass word
Card or PIN: Access programming mode → 15 PPPP [Input 4-digit pass code, default value: 4321]
Card and PIN: Access programming mode → 17 PPPP [Input 4-digit pass code, default value: 1234; PPPP=0000: change into Card Only]
E. Dual Door Control(M4/M8)
Controller with an reader to do the "Dual Door Control".
Access programming mode → 28 064 [064= Dual Door Control]
F. Anti-pass-back(M4/M8)
Usually, anti-pass-back is commonly applied to parking areas in order to prevent from multi-entry with one card at a time, or to situations need access and exit monitor.
Enable controller
Access programming mode → 20 DDD [128= Anti-pass-back(0=Disable; 1=Enable)/ 064=Access/Exit(0=Exit; 1=Access).]
[e.g.] Enable Anti-pass-back, and set to Exit door= (128 x 1) + (064 x 0) = 128
Access programming mode → 20 128 (Please refer to function default value for details.)
Enable card
Access programming mode → 26 SSSSS EEEEE N
[SSSSS= User address start; EEEEE= User address end; N=0(control)/ 1(Not control)/ 2(reset)]
[e.g.] User address from 00152 to 00684 enable the anti-pass-back function: 26 00152 00684 0
[e.g.] No. 154 enable the anti-pass-back, and induction into the door has not been induced to leave. When he represent into the door will become
invalid , then he needs to set the reset. Access programming mode → 26 00154 00154 2 → Reset
G. Auto Open Time Zone
Door will keep open after the first flashing card.There are 2 time zones supported when Stand-Alone, and 63 time zones when it connect to AR-716E.
Enable/Disable auto open zone
Access programming mode → 20 004 [004= enable Auto-Open Time Zone; 000= disable Auto-Open Time Zone]
Enable/Disable auto open door without presenting card
Access programming mode → 24 001 [001= enable Auto-Open Time Zone; 000= disable Auto-Open Time Zone]
Set up open time
Access programming mode → 08 N HHMMhhmm 6543217H
N: 2 sets of auto-open zone (N=0=1st set; N=1=2nd set)
HHMMhhmm=Staring time to ending time (e.g. 08301200=08:30 to 12:00)
6543217H= 7 days of week + Holiday (Sat/Fri/Thu/Wed/Tue/Mon/Sun) (F= 0: disable; 1: enable); Holidays establish by the software.
[e.g.] To set the second time zone as 9:30 AM to 4:20 PM, Monday, Wednesday and Friday: 08 1 09301612 01010100 → Done
H. Lift control
Connect with AR-401RO16B to control floors which the user will be able to access.
Enable
Access programming mode → 24 002 [002= enable lift control]
Single floor
Access programming mode → 27 UUUUU FF
UUUU=User Address FF=Floor number (01~32 floor)
[e.g.] User address NO. 45, allow to access the 24th floor: 27 00045 24
Please refer to below floor chart
Set
2
3
0
1
Floor/ Stop
F
8
16
24
32
F
7
15
23
31
F
6
14
22
30
Multi floors
Access programming mode → 21 UUUUU S FFFFFFFF
[UUUUU=User address S: 4 sets of lift control (Input: 0~3) FFFFFFFF: 8 floors setting (F=0=Disable, F=1=Enable)
[e.g.] User address NO. 168, only to the 6th and the 20th floor:
Access programming mode → 21 00168 0 00100000 → 21 00168 2 00001000
F
5
13
21
29
F
4
12
20
28
F
3
11
19
27
F
2
10
18
26
F
1
9
17
25
SOYAL
ACCESS CONTROL SYSTEM
® AR-321H/AR-331H/
AR-721H/AR-725H/AR-757H
V110412
I. Setting Up the Arming
Alarm conditions:
1. Arming is enabled
2.Alarm system connected
Application:
1. Door open too long : Door is open longer than door relay time plus door close time.
2. Force open (Opened without a valid user card): Access by force or illegal procedure.
3. Door position abnormal : Arming is enabled and the power is suddenly off then on.
Enable/Disable Arming status (for M4/M8; Factory default armingcode is: 1234) :
Standby Mode
After door open Do not open the door
The normal procedure to open door → Input 4 digit arming code → → Input 4 digit arming code → Present valid card
Enter Program Mode
Enable: Access programming mode →
※ [The normal procedure to open door] can refer to [Access Mode].
Disable: Access programming mode →
Function Default Value
AR-321H / AR-331H/ AR-721H / AR-725H / AR-757H
20 DDD
Function
Attendance
Auto Re-lock
Auto Open
Door open button input
Master Controller of Network
Access/Exit
Anti-pass-back
※ 0: Yes
Selection
1: No
※ 0: Disable
※ 0: Disable
0: Disable
1: Enable
1: Enable
※ 1: Enable
※ 0: Slave
※ 0: Exit
※ 0: Disable
1: Mater
1: Access
1: Enable
※ Default Value
Value Application
001 Networking
002
004
016
Networking/Stand-Alone
Networking/Stand-Alone
Networking/Stand-Alone
032
064
128
Networking
Networking
Networking
Selection= 0(none value)/ 1(1 x each value)
[e.g.] DDD value of Enable “Auto Open” + ”Exit by
Push Button +”Anti-pass-back” =004+016+128=148;
As a result of that, the command will be 20 148 .
28 DDD
Function
Dual Door Control
Force Open Alarm Output
Selection
※ 0: Disable 1: Enable
※ 0: Disable 1: Enable
※ Default Value
Value Application
064
128
Networking/Stand-Alone
Networking/Stand-Alone
AR-321H / AR-331H / AR-721H / AR-725H
24 DDD
Function Selection
※ Default Value
ValueApplication
Auto-open door without ※ 0: Disable 1: Enable 001 Networking/Stand-Alone cards at auto open zone
Alarm Output/ Lift
Control
Stop Alarm by door close or by push button
Door bell
※ 0: Alarm Output 1: Lift Control
0: None
※ 0: Disable
※ 1: Yes
1: Enable
002
064
128
Networking/Stand-Alone
Networking/Stand-Alone
Networking/Stand-Alone
AR-757H
24 DDD
Function
Auto-open door without cards at auto open zone
Selection
※ 0: Disable 1: Enable
Lift Control/
Duress Function
※ 0: Lift Control
Stop Alarm by door open 0: None or door close button
1: Duress
※ 1: Yes
※ Default Value
ValueApplication
001 Networking/Stand-Alone
002
064
Networking/Stand-Alone
Networking/Stand-Alone
Mode4 / Mode6 / Mode8
Mode
M4
Networking/
Stand-Alone
Networking/
Stand-Alone
User
Capacity
1,024
(721H/757H)
3,000
(321H/331H/
725H)
Access Mode
1.Card only
2.Card and PIN (4-digit PIN) +
3.Card or User address (5-digit) + Individual PIN (4-digit individual PIN) +
Auto-show
Duty time
Yes
Event log
Capacity
1,200 (721H)
1,500
(321H/331H/
725H)
3,000 (757H)
120
Holidays
Yes
Anti force
Yes
Time
Zone
11
Lift
Control
32
Anti-passback
Yes
M6
M8
Stand-Alone
Networking/
Stand-Alone
65,535
1,024
(721H/757H)
3,000
(321H/331H/
725H)
1.Card only
2.Card and PIN (4-digit public PIN= Arming PWD) +
3.Card or PIN (4-digit public PIN= Duress code)
1.Card only
2.Card and PIN (4-digit individual PIN) +
3.Card or PIN (4-digit individual PIN)
No
Yes
No
1,200 (721H)
1,500
(321H/331H/
725H)
3,000 (757H)
No
Yes
No
Yes
No
11
No
32
No
Yes
※ Mode 6, the number of users up to 65535, since it reads CARD CODE (5 digits) only, unlike that Mode4/Mode8 read SITE CODE and CARD CODE (10 digits).
Factory Reset by its commands
When the device is stand-alone (not networking)
Access programming mode → 20 016 → 24 064 → 26 00000 01023 1 → 28 000 → 29 29
※ Note: After the Master Code is changed, factory reset doesn’t restore the Master Code back to 123456.
Access Controller
Touch-panel Metal Housing / Illuminated Touch-panel V110412
Command List
Function
Entering programming mode
Exiting programming mode
Exiting programming mode and enabling arming status
Node ID setting (Connecting to 716E)
Node ID setting (Connecting to PC directly without via 716E)
Mifare tag / card format (Optional)
Door relay time setting
Alarm relay time setting
Control mode setting
Arming delay time setting
Alarm delay time setting
Master card setting
Auto-open time zone setting
Master code setting
Suspend / Delete tag
Set a sequence of cards as "read and access"
Active the suspended cards
Set the cards as Card mode OR PIN mode by user address
Set the cards as Card AND PIN mode by user address
Arming output time setting
M4/M8: Duress code setting
M6: Public PIN setting (Card or PIN)
Card number modification
M4/M8: Arming pass code setting
M6: Public PIN setting (Card and PIN)
Door open waiting time
Set the card by induction(M4/M8)
Reader additional setting
Lift control setting: multi-doors
Add/Delete tag by induction (M6 only)
AR-401ROsite number dip switch
Controller parameter setting
Controller time clock setting
Anti-pass-back (Enable user)
Single floor setting
Dual door control/ Active or inactive arming for force open
Delete all tags
Enable the security trigger signal ( with AR-721RB)
Command
PPPPPP
Description
PPPPPP=Master Code, default value= 123456
00 NNN
00 NNN VVV nnn
01 N
02 TTT
03 TTT
04 N
05 TTT
06 TTT
07 SSSSS EEEEE
08 N HHMMhhmm 654327H
NNN=Node ID , range: 001~254
NNN=Node ID of Access Controller, VVV=Virtual 716E Node ID, nnn=Door number; range:001~254
N: 0=ISO14443A; 1=ISO14443B; 2=ISO15693;
3=I Code1; 4=I Code2
PS.1. Please select the compliance,first.
2. Make sure reader and card using the same compliance.
TTT=Door relay time 000= Output constantly
001~600=1~600 sec.
601~609=0.1~0.9 sec.
TTT=Alarm relay time 001~600=1~600 sec.
N=Mode 4=Mode4 ; 6=Mode6 ; 8=Mode8
TTT=Arming delay time 001~600=1~600 sec.
TTT=Alarm delay time 001~600=1~600 sec.
SSSSS-EEEEE=00000-01023 (00000-03000 for AR-725H);
SSSSS=Starting user address; EEEEE=Ending user address
N= 0(1st time zone) / 1(2nd time zone)
HHMM= Starting time; hhmm= ending time
(i.e.: 08301200=08:30 to 12:00)
09 PPPPPPRRRRRR
6543217H= 7 days of week (Sat/Fri/Thu/Wed/Tue/Mon/Sun)+ Holiday
(F= 0: disable; 1: enable); Holidays establish by the software.
PPPPPP=New master code
RRRRRR=Repeat the new master code
10 SSSSS EEEEE
11 SSSSS EEEEE
11 SSSSS EEEEE
SSSSS=Starting user address, EEEEE=Ending user address
SSSSS=Starting card number
EEEEE=Ending card number
SSSSS=Starting user address
EEEEE=Ending user address
Access mode: Card or PIN ; UUUUU=user address; 12 UUUUU PPPP
13 UUUUU PPPP
PPPP=4-digit pass code 0001~9999
Access mode: Card and PIN ; UUUUU=user address;
PPPP=4-digit pass code 0001~9999
TTT=Arming output time; 000~250=0~2.5 sec.
14 TTT
15 PPPP
PPPP=4-digit pass code (default value= 4321 )
P.S. Duress code will be unavailable and become a public PIN at access mode “ Card or PIN ” of M6
16 UUUUU SSSSSCCCCC
17 PPPP
UUUUU= User address; SSSSS=5-digit site code; CCCCC=5-digit card code
PPPP=4-digit pass code ( default value= 1234 ; disable Arming PWD= 0000 )
P.S. Arming PWD code will be unavailable and become a public PIN at access mode “ Card PIN ” and of M6
18 TTT
19 UUUUU QQQQQ
TTT=Door open waiting time: 001~600=1~600 sec.; default value: 15 sec.
UUUUU=User address;
QQQQQ=Card quantity( 00001 =Continuously inducting)
Please refer to function default value for details.
20 DDD
21 UUUUU S FFFFFFFF
22 N
23 NNN TTT
24 DDD
25 YYMMDDHHmmss
26 SSSSS EEEEE N
UUUUU=User address, S=4 sets of lift control(0~3); FFFFFFFF=8 assigned floor
(F=0: Disable, 1: Enable)
N=0(Delete tag); N=1(Add tag)
NNN=site number, TTT= relay time: 000~600=1~600 sec.
Please refer to function default value for details.
YYMMDDHHmmss: Year/ Month/ Day/ Hour/ Min./ Sec.
SSSSS=Starting user address; EEEEE=Ending user address;
N=0/Enable; N=1/Disable; N=2/Initial
UUUUU=User Address; FF=Floor (01~32 floor) 27 UUUUU FF
28 DDD
29 29
34 128 (321H/721H/725H/757H)
34 064 (331H) 34 000 (Disable)
Please refer to function default value for details.
controller is connected with AR-721RB.
Mode
M4/M6/M8
M4//M6M8
M4/M8
M4/M8
M4/M8
M4/M8
M4/M6M8
M4/M6/M8
M4/M6/M8
M4/M6/M8
M4/M6/M8
M4/M8
M4/M6/M8
M4/M6/M8
M4/M6/M8
M6
M4/M8
M4/M8
M4/M8
M4/M8
M4/M6/M8
M4/M8
M4/M6/M8
M4/M6/M8
M4/M8
M4/M6/M8
M4/M8
M6
M4/M8
M4/M6/M8
M4/M6/M8
M4/M8
M4/M8
M4/M6/M8
M4/M6/M8
M4/M6/M8
advertisement
Related manuals
advertisement