SOYAL

ACCESS CONTROL SYSTEM

® AR-321H/AR-331H/

AR-721H/AR-725H/AR-757H

Contents

AR-321H [Touch-panel Metal Housing]

1 Product 2 User Guide 3 Terminal Cables 4 Tools 5 Water proof Strip

V110412

P7 d x2

P1 P2 P3 P4

AR-331H [Touch-panel Metal Housing]/ AR-331H-S [Metal Housing]

1 Product 2 Optional 3 User Guide

[Optional] or

AR-721RB

Digital Relay or

WG keyboard

AR-331H-S

AR-821RB

Original Relay AR-331H

AR-721H

1 Product 2 User Guide 3 Terminal Cables

4 Terminal Cables

P8

※ Must to purchase relay

5 Tools c x2 g x1 h x1

Protection Plug

4 Tools f x2

P1 P2 P3 P4

AR-725H [Illuminated Touch-panel]

AR-725H-M

1 Products 2 User Guide 3 Terminal Cables 4 Tools

A.

AR-725H

1 Products

A1.

AR-725X

1 Products

A2.

AR-757H

1 Product

B.

A3.

Parts Description

a.

Button Head Pozidriv

Tapping Screw: M3x10 e.

E.

B.

C.

F.

C.

D.

2 User Guide

G.

b.

Button Head Pozidriv

Slotting Screw: 2.5x10

f.

P1 P2

P3

3 Terminal Cables

P4 c x2 e x1

2 User Guide 4 Tools f x2

P1 P2

P3 P4

2 Tools a x2 b x2 c x2 e x1

H.

D.

3 Terminal Cables 4 Tools f x2

P1 P2 P3 P4 P6 c.

Flat Head Cap Philips

Tapping Screw: 4x19.1

g.

Security Torx Screw: M3x10 d.

h.

Flat Head Cap Philips

Tapping Screw: 4x38

Security Torx Wrenches

Installation

AR-321H

3

AR-331H

4

1

2

3

2

1

AR-721H

Access Controller

Touch-panel Metal Housing / Illuminated Touch-panel V110412

Pull the cables from the square hole of the mounting plate.

Use a screwdriver to screw the mounting plate onto the wall.

Attach the water proof strip to the body, then connect the terminal cables to the body and attach the body to the mounting plate.

Use the Allen key and screws (accessories supplied) to assemble the body onto the mounting plate.

Turn on the power, and LED will light and beep will sound.

4 5

To cut tamper-resistant column and make it fit the appropriate height for actual installation.

First, take off the metal casing then screw the controller on the wall.

Second, put the metal casing back and lock it with security screw.

Finally, put the Protection plug into the hole.

Turn on the power, and LED will light and beep will sound.

4

AR-725H

AR-725H-M

2 c.

1

C.

A.

3

B.

4

A.

AR-725H

1

F.

5

B.

A1.

E.

3 e.

5

C.

A.

B.

6

A.

D.

8 d.

F.

4

2

7

C.

Pull the cables from the square access hole of the mounting plate C .

Use a screwdriver to screw the metal plate C onto the wall.

Take off the plastic mounting plate B from the body A , and pull the cables through the access hole of C and B , then connect to the body A .

Assemble plate B with the body A , and embed the water proof strip D onto the plastic side frame.

Assemble the body A onto the mounting plate C with the Allen key and screws (accessories supplied).

Turn on the power and LED will light and beep will sound.

Use a screwdriver to screw the base F onto the wall.

Attach the water proof gasket to the body A1 , and pull the cables from the square hole of the base F, and connect to the body A1 .

Assemble the body A1 with the base F .

Screw A1 and F tight with the Allen key and screws (accessories supplied).

Turn on the power and LED will light and beep will sound.

AR-725X

A1.

1

A3.

G.

AR-757H

2 b.

e.

3

A2.

H.

A1.+A3.

4

D.

a.

5

Put on G , and attach A1 onto the plastic plate A3 , and screw it with the Allen key and screws (accessories supplied).

Put the ring O on the metal frame, and put them together onto the reader A1 + A3 , and screw them and buckle up the 4 buckles on the back.

Embed the water proof strip D onto the frame side of the base.

Following by the install process of AR-725H-M.

4

Pull the cables from the square hole of the mounting plate.

Use a screwdriver to screw the base onto the wall.

Connect the terminal cables to the body and attach the body to the mounting plate.

Assemble the covers with the Allen key and screws (accessories supplied).

Turn on the power and LED will light and beep will sound.

SOYAL

ACCESS CONTROL SYSTEM

® AR-321H/AR-331H/

AR-721H/AR-725H/AR-757H

V110412

Notice

1.Tubing: The communication wires and power line should NOT be bound in the same conduit or tubing.

2.Wire selection:

3.Power supply:

Use AWG 22-24 Shielded Twist Pair to avoid star wiring.

Don’t equip controller and lock with the same power supply. The power for controller may be unstable when the lock is activating, that may make the controller malfunction.

The standard installation: Door relay and lock use the same power supply, and controller use independent power supply.

Connector Table

125kHz

13.56MHz

AR-331H

125kHz

13.56MHz

AR-721H

125kHz

P3

P2

P3

P7

10 9 8 7 6 5 4 3 2 1

P1

P4

P1

P5

P2

3

4

1

2

5

P8

13.56MHz

P2

P1

Cable:

P1

Wire Application

Lock Relay

Common-COM-Point

Door contact

Exit Switch

Alarm Relay

Power

6

7

4

5

8

Pin

1

2

3

Color

Blue White

Purple White

White

Orange

Purple

Gray

Thick Red

Thick Black

Description

(N.O.) DC24V1Amp

(N.C.) DC24V1Amp

(COM) DC24V1Amp

Negative Trigger Input

Negative Trigger Input

Low output; Max 12V/100mA (Open Collector)

DC Power 12V

DC Power 0V

Cable:

P2

Wire Application

Wiegand

Beeper

LED

Pin

1

2

3

4

5

Color

Thin Blue

Thin Green

Pink

Brown

Yellow

Description

Wiegand DAT:1 Input

Wiegand DAT:0 Input

Beeper Output 5V/100mA, Low

LED Green Output 5V/20mA, Max

LED Red Output 5V/20mA, Max

Cable:

P3

Wire Application

Networking

Module

Pin

1

2

Color

Thick Green

Thick Blue

Description

RS-485(B-)

RS-485(A+)

Cable:

P4

Contact Rating: 1A 125VAC/24VDC

Wire Application

Tamper Switch

Pin

1

2

3

Color

Red

Orange

Yellow

Description

N.C.

COM

N.O.

※ After S/N: 0706-XXXXXX

P4

AR-725H

125kHz

P2 P3

P5

P4

13.56MHz

P5

P5

P2

P3

Cable:

P5

(Optional)

Wire Application

3-PIN Connector

Pin

1

2

3

Color

Black

White

Purple

Description

GND.

Duress

Arming/ Security trigger signal

AR-757H

125kHz Main Board

P3

P4

P2

P4

P1

P6

P5

I/O Board

P1

P4

13.56MHz

P3

P2

P4

P1

P3

Main Board

P6

I/O Board

P1

Connectors Comparison

AR-321H

AR-331H

AR-721H

AR-725H

AR-757H

P1 P2 P3 P4

P7 P8

P1 P2 P3 P4

P1 P2 P3 P4

(

(

(

P1 P2 P3 P4 P6

Optional

Optional

Optional

)

)

)

Cable:

P6

Wire Application

Door bell

Arming

Duress

LED indicator

Pin

1

2

3

4

Color

Brown White

Red White

Yellow White

Green White

Description

BE Output

AR Output/ Security trigger signal Output

DU Output/ TTL out

Hi input/ Green light brighten

Cable:

Power

P7

Exit Switch

Lock Relay

Alarm Relay

Door contact

(Directly connected at the Access controller)

Wire Application

Networking Module

Networking Module

Tamper Switch

Pin

1

2

3

4

5

6

7

8

9

10

Color

Black

Red

Purple

Green

White

Blue

Yellow

Brown

Gray

Orange

Description

DC Power 0V

DC Power 12V

Negative Trigger Input

RS-485(B-)

Low output; Max 12V/100mA (Open Collector)/

Security trigger signal Output

RS-485(A+)

N.O.

COM

Low output; Max 12V/100mA (Open Collector)

Negative Trigger Input

Cable:

Beeper

Wiegand

P8 (for external WG Reader)

Wire Application

LED

Pin

1

2

3

4

5

Color

Brown

Yellow

White

Blue

Green

Description

LED Green Output 5V/20mA, Max

LED Red Output 5V/20mA, Max

Beeper Output 5V/100mA, Low

Wiegand DAT:1 Input

Wiegand DAT:0 Input

Access Controller

Touch-panel Metal Housing / Illuminated Touch-panel V110412

Wiring Diagram

Connect to Magnet Lock or Electric Bolt

12V

GND or

12V

GND

Electric Bolt Magnet Lock

Controller

POWER

12VDC

Connect to Reader

N.C.

COM

PB

12V

GND

P1

3

4

1

2

5

6

7

8

12V

GND

N.O.

POWER

12VDC

EXIT

Request To Exit

Reader

Connect to Electric Strike

12V

GND

Electric Strike

N.O.

COM

PB

12V

GND

P1

5

6

7

8

1

2

3

4

Controller

POWER

12VDC

12V

GND

Connect to Door Sensor

12V

POWER

12VDC

GND

WG 1

WG 0

BZ

GLED

RLED

12V

GND

POWER

12VDC

GND

12V

Controller

3

4

1

2

5

P2

WG 1

WG 0

BZ

GLED

RLED

P1

3

4

1

2

5

6

7

8

12V

GND

Door Contact

ALM

12V

GND

P1

5

6

7

8

1

2

3

4

Controller

POWER

12VDC

12V

GND

Connect to Networking

Converter

A+

B-

Strengthen security with AR-721RB

12V

GND

12V

GND

POWER

12VDC

Electric Bolt

P5

1 2 3

ARM

12V

GND

3

4

5

1

2

6

7

8

P1

N.C.

N.O.

COM

CTL

12V

GND

PB

AR-721RB

N.O.

Controller

EXIT

POWER

12VDC

12V

GND

Request To Exit

※ 1.Enable the security trigger signal: Please refer to the 34 DDD

2.Disable the door open button input. (Please refer to the

20 DDD of function default value.)

Connect to Access Control for

P7

Lock

PB

12V

GND

7

6

5

4

10

9

8

3

2

1

POWER

12VDC

Request To Exit

N.O.

12V

GND

P7

AR-331H

Electric Bolt

Relay Outpot Module

EXIT

N.C.

N.O.

COM

CTL

12V

POWER

12VDC

If use the AR-721RB, please refer to the top of the wiring diagram.

Node ID 001

AR-716E

Host

CH1

CH2

B-

A+

B-

A+

B-

A+

Controller

Node ID 254

P3

B-

A+

1

2

Connect to arming tools for

Door Contact

P7

AR-331H

Door

Contact

ALM

COM

N.O.

P7

12V

GND

6

5

4

3

2

1

8

7

10

9

N.C.

POWER

12VDC

12V

GND

12V

GND

N.C.

N.O.

COM

CTL

12V

Relay Outpot Module

N.C.

Node 1

P3

B-

A+

1

2

Controller

Controller

P3

B-

A+

1

2

Node 9

N.C.

N.O.

COM

CTL

12V

12V

CTL

COM

N.O.

N.C.

N.O.

POWER

12VDC

Alarm

EXIT

Request To Exit

Door Contact

GND

12V

POWER

12VDC

Node 8

P3

B-

A+

1

2

Controller

Controller

P3

B-

A+

1

2

Node 16

Alarm

Alarm Relay

Tamper Relay

Tamper Alarm

SOYAL

ACCESS CONTROL SYSTEM

® AR-321H/AR-331H/

AR-721H/AR-725H/AR-757H

V110412

Connect to Reader for

Reader

GLED

RLED

BZ

WG 1

WG 0

GND

12V

P8

AR-331H

P8

1

2

3

4

5

10

9

8

7

6

5

4

3

2

1

P7

12V

GND

Connect to Networking for

POWER

12VDC

12V

GND

P7

A+

B-

6

5

4

3

10

9

8

7

2

1

P7

A+

B-

Converter

B-

A+

B-

A+

B-

A+

Host

CH1

CH2

AR-716E

POWER

12VDC

GND

12V

AR-331H

External WG keyboard

※ If you want to program system on AR-331H-S directly, please order WG keyboard then install it according to the following pattern.

1

2

3

Remove the Protection plug that in the bottom right.

( ※ Do not lose protection plug or it will affect the protection level.)

WG Keyboard cable will be connected to the pin board.

WG Keyboard connected to the controller from the bottom right of the hole.

When you finish programming system, please put protection plug back to the controller.

Adding and Deleting Tag

Mode4/Mode8

Add Single Tag or Random tags

Input 123456 (or Master Code) → 19 UUUUU 00001 → Present the tag(s) with Controller (single tag or random numbered cards one by one) → Done

[e.g.] 2 readom cards with user addresses No. 100 and No. 101:

Access programming mode → 19 00100 00001 → Present the tags one by one → Done

Add the Sequential tags

Input 123456 (or Master Code) → 19 UUUUU QQQQQ → Present the tags (Present the tag with the lowest number first.) → OK

[e.g.] User Address NO.101 to NO.120 have 20 pcs of sequential tags:(62312~62332) :

Access programming mode → 19 00101 00120 → Close Tag into RF Area (only use the tag NO.62312

) → OK

Delete a Single Tag

Input 123456 (or Master Code) → 10 SSSSS EEEEE

[e.g.] Delete User Address: 00058

Access programming mode → 10 00058 00058

Tag Information

Delete a batch of Tags

Input 123456 (or Master Code) → 10 SSSSS EEEEE

[e.g.] Delete User Address: 00101~00245

Access programming mode → 10 00101 00245

CARD CODE

SITE CODE

CARD CODE

SITE CODE

Delete All Tags

Input 123456 (or Master Code) → 29 29

Mode6

※ At this mode, User Address = Card Code

Add Tags

Input 123456 (or Master Code) → 11 SSSSS EEEEE → OK

[e.g.] Add User Address: 00100~01254

Access programming mode → 11 00100 01254 → OK

Delete Tags

Input 123456 (or Master Code) → 10 SSSSS (or )EEEEE → OK

[e.g.] Delete a tag with card code 62362

Access programming mode → 10 62362 62362 → OK

Delete All Tags

Input 123456 (or Master Code) → 29 29

Operation process

A. Enter/ Exit Program Mode

Enter the program mode

Input 123456 or PPPPPP

[e.g.] The Default Value= 123456, if already changed the Master Code= 876112, input 876112 → program mode accessed

Exit the program mode

Input

Access Controller

Touch-panel Metal Housing / Illuminated Touch-panel V110412

Master Code modification

Access programming mode → 09 PPPPPPRRRRRR [Input the 6-digit new master code twice.]

[e.g.] Set the Master code to be 876112, input 123456 → 09 876112876112

B. Chang the Node ID of Controller

Access programming mode → 00 NNN [Node ID: 001~254]

C.Set up M4/M6/M8

Access programming mode → 04 N [N=4/6/8]

D. Set up the password

M4/M8: Individual pass code

Card or PIN: Access programming mode → 12 UUUUU PPPP [e.g. User address: 00001 and pass code: 1234, input 12 00001 1234 ]

Card and PIN: Access programming mode → 13 UUUUU PPPP [e.g. User address: 00001 and pass code: 1234, input 13 00001 1234 ]

M6: Public pass word

Card or PIN: Access programming mode → 15 PPPP [Input 4-digit pass code, default value: 4321]

Card and PIN: Access programming mode → 17 PPPP [Input 4-digit pass code, default value: 1234; PPPP=0000: change into Card Only]

E. Dual Door Control(M4/M8)

Controller with an reader to do the "Dual Door Control".

Access programming mode → 28 064 [064= Dual Door Control]

F. Anti-pass-back(M4/M8)

Usually, anti-pass-back is commonly applied to parking areas in order to prevent from multi-entry with one card at a time, or to situations need access and exit monitor.

Enable controller

Access programming mode → 20 DDD [128= Anti-pass-back(0=Disable; 1=Enable)/ 064=Access/Exit(0=Exit; 1=Access).]

[e.g.] Enable Anti-pass-back, and set to Exit door= (128 x 1) + (064 x 0) = 128

Access programming mode → 20 128 (Please refer to function default value for details.)

Enable card

Access programming mode → 26 SSSSS EEEEE N

[SSSSS= User address start; EEEEE= User address end; N=0(control)/ 1(Not control)/ 2(reset)]

[e.g.] User address from 00152 to 00684 enable the anti-pass-back function: 26 00152 00684 0

[e.g.] No. 154 enable the anti-pass-back, and induction into the door has not been induced to leave. When he represent into the door will become

invalid , then he needs to set the reset. Access programming mode → 26 00154 00154 2 → Reset

G. Auto Open Time Zone

Door will keep open after the first flashing card.There are 2 time zones supported when Stand-Alone, and 63 time zones when it connect to AR-716E.

Enable/Disable auto open zone

Access programming mode → 20 004 [004= enable Auto-Open Time Zone; 000= disable Auto-Open Time Zone]

Enable/Disable auto open door without presenting card

Access programming mode → 24 001 [001= enable Auto-Open Time Zone; 000= disable Auto-Open Time Zone]

Set up open time

Access programming mode → 08 N HHMMhhmm 6543217H

N: 2 sets of auto-open zone (N=0=1st set; N=1=2nd set)

HHMMhhmm=Staring time to ending time (e.g. 08301200=08:30 to 12:00)

6543217H= 7 days of week + Holiday (Sat/Fri/Thu/Wed/Tue/Mon/Sun) (F= 0: disable; 1: enable); Holidays establish by the software.

[e.g.] To set the second time zone as 9:30 AM to 4:20 PM, Monday, Wednesday and Friday: 08 1 09301612 01010100 → Done

H. Lift control

Connect with AR-401RO16B to control floors which the user will be able to access.

Enable

Access programming mode → 24 002 [002= enable lift control]

Single floor

Access programming mode → 27 UUUUU FF

UUUU=User Address FF=Floor number (01~32 floor)

[e.g.] User address NO. 45, allow to access the 24th floor: 27 00045 24

Please refer to below floor chart

Set

2

3

0

1

Floor/ Stop

F

8

16

24

32

F

7

15

23

31

F

6

14

22

30

Multi floors

Access programming mode → 21 UUUUU S FFFFFFFF

[UUUUU=User address S: 4 sets of lift control (Input: 0~3) FFFFFFFF: 8 floors setting (F=0=Disable, F=1=Enable)

[e.g.] User address NO. 168, only to the 6th and the 20th floor:

Access programming mode → 21 00168 0 00100000 → 21 00168 2 00001000

F

5

13

21

29

F

4

12

20

28

F

3

11

19

27

F

2

10

18

26

F

1

9

17

25

SOYAL

ACCESS CONTROL SYSTEM

® AR-321H/AR-331H/

AR-721H/AR-725H/AR-757H

V110412

I. Setting Up the Arming

Alarm conditions:

1. Arming is enabled

2.Alarm system connected

Application:

1. Door open too long : Door is open longer than door relay time plus door close time.

2. Force open (Opened without a valid user card): Access by force or illegal procedure.

3. Door position abnormal : Arming is enabled and the power is suddenly off then on.

Enable/Disable Arming status (for M4/M8; Factory default armingcode is: 1234) :

Standby Mode

After door open Do not open the door

The normal procedure to open door → Input 4 digit arming code → → Input 4 digit arming code → Present valid card

Enter Program Mode

Enable: Access programming mode →

※ [The normal procedure to open door] can refer to [Access Mode].

Disable: Access programming mode →

Function Default Value

AR-321H / AR-331H/ AR-721H / AR-725H / AR-757H

20 DDD

Function

Attendance

Auto Re-lock

Auto Open

Door open button input

Master Controller of Network

Access/Exit

Anti-pass-back

※ 0: Yes

Selection

1: No

※ 0: Disable

※ 0: Disable

0: Disable

1: Enable

1: Enable

※ 1: Enable

※ 0: Slave

※ 0: Exit

※ 0: Disable

1: Mater

1: Access

1: Enable

※ Default Value

Value Application

001 Networking

002

004

016

Networking/Stand-Alone

Networking/Stand-Alone

Networking/Stand-Alone

032

064

128

Networking

Networking

Networking

Selection= 0(none value)/ 1(1 x each value)

[e.g.] DDD value of Enable “Auto Open” + ”Exit by

Push Button +”Anti-pass-back” =004+016+128=148;

As a result of that, the command will be 20 148 .

28 DDD

Function

Dual Door Control

Force Open Alarm Output

Selection

※ 0: Disable 1: Enable

※ 0: Disable 1: Enable

※ Default Value

Value Application

064

128

Networking/Stand-Alone

Networking/Stand-Alone

AR-321H / AR-331H / AR-721H / AR-725H

24 DDD

Function Selection

※ Default Value

ValueApplication

Auto-open door without ※ 0: Disable 1: Enable 001 Networking/Stand-Alone cards at auto open zone

Alarm Output/ Lift

Control

Stop Alarm by door close or by push button

Door bell

※ 0: Alarm Output 1: Lift Control

0: None

※ 0: Disable

※ 1: Yes

1: Enable

002

064

128

Networking/Stand-Alone

Networking/Stand-Alone

Networking/Stand-Alone

AR-757H

24 DDD

Function

Auto-open door without cards at auto open zone

Selection

※ 0: Disable 1: Enable

Lift Control/

Duress Function

※ 0: Lift Control

Stop Alarm by door open 0: None or door close button

1: Duress

※ 1: Yes

※ Default Value

ValueApplication

001 Networking/Stand-Alone

002

064

Networking/Stand-Alone

Networking/Stand-Alone

Mode4 / Mode6 / Mode8

Mode

M4

Networking/

Stand-Alone

Networking/

Stand-Alone

User

Capacity

1,024

(721H/757H)

3,000

(321H/331H/

725H)

Access Mode

1.Card only

2.Card and PIN (4-digit PIN) +

3.Card or User address (5-digit) + Individual PIN (4-digit individual PIN) +

Auto-show

Duty time

Yes

Event log

Capacity

1,200 (721H)

1,500

(321H/331H/

725H)

3,000 (757H)

120

Holidays

Yes

Anti force

Yes

Time

Zone

11

Lift

Control

32

Anti-passback

Yes

M6

M8

Stand-Alone

Networking/

Stand-Alone

65,535

1,024

(721H/757H)

3,000

(321H/331H/

725H)

1.Card only

2.Card and PIN (4-digit public PIN= Arming PWD) +

3.Card or PIN (4-digit public PIN= Duress code)

1.Card only

2.Card and PIN (4-digit individual PIN) +

3.Card or PIN (4-digit individual PIN)

No

Yes

No

1,200 (721H)

1,500

(321H/331H/

725H)

3,000 (757H)

No

Yes

No

Yes

No

11

No

32

No

Yes

※ Mode 6, the number of users up to 65535, since it reads CARD CODE (5 digits) only, unlike that Mode4/Mode8 read SITE CODE and CARD CODE (10 digits).

Factory Reset by its commands

When the device is stand-alone (not networking)

Access programming mode → 20 016 → 24 064 → 26 00000 01023 1 → 28 000 → 29 29

※ Note: After the Master Code is changed, factory reset doesn’t restore the Master Code back to 123456.

Access Controller

Touch-panel Metal Housing / Illuminated Touch-panel V110412

Command List

Function

Entering programming mode

Exiting programming mode

Exiting programming mode and enabling arming status

Node ID setting (Connecting to 716E)

Node ID setting (Connecting to PC directly without via 716E)

Mifare tag / card format (Optional)

Door relay time setting

Alarm relay time setting

Control mode setting

Arming delay time setting

Alarm delay time setting

Master card setting

Auto-open time zone setting

Master code setting

Suspend / Delete tag

Set a sequence of cards as "read and access"

Active the suspended cards

Set the cards as Card mode OR PIN mode by user address

Set the cards as Card AND PIN mode by user address

Arming output time setting

M4/M8: Duress code setting

M6: Public PIN setting (Card or PIN)

Card number modification

M4/M8: Arming pass code setting

M6: Public PIN setting (Card and PIN)

Door open waiting time

Set the card by induction(M4/M8)

Reader additional setting

Lift control setting: multi-doors

Add/Delete tag by induction (M6 only)

AR-401ROsite number dip switch

Controller parameter setting

Controller time clock setting

Anti-pass-back (Enable user)

Single floor setting

Dual door control/ Active or inactive arming for force open

Delete all tags

Enable the security trigger signal ( with AR-721RB)

Command

PPPPPP

Description

PPPPPP=Master Code, default value= 123456

00 NNN

00 NNN VVV nnn

01 N

02 TTT

03 TTT

04 N

05 TTT

06 TTT

07 SSSSS EEEEE

08 N HHMMhhmm 654327H

NNN=Node ID , range: 001~254

NNN=Node ID of Access Controller, VVV=Virtual 716E Node ID, nnn=Door number; range:001~254

N: 0=ISO14443A; 1=ISO14443B; 2=ISO15693;

3=I Code1; 4=I Code2

PS.1. Please select the compliance,first.

2. Make sure reader and card using the same compliance.

TTT=Door relay time 000= Output constantly

001~600=1~600 sec.

601~609=0.1~0.9 sec.

TTT=Alarm relay time 001~600=1~600 sec.

N=Mode 4=Mode4 ; 6=Mode6 ; 8=Mode8

TTT=Arming delay time 001~600=1~600 sec.

TTT=Alarm delay time 001~600=1~600 sec.

SSSSS-EEEEE=00000-01023 (00000-03000 for AR-725H);

SSSSS=Starting user address; EEEEE=Ending user address

N= 0(1st time zone) / 1(2nd time zone)

HHMM= Starting time; hhmm= ending time

(i.e.: 08301200=08:30 to 12:00)

09 PPPPPPRRRRRR

6543217H= 7 days of week (Sat/Fri/Thu/Wed/Tue/Mon/Sun)+ Holiday

(F= 0: disable; 1: enable); Holidays establish by the software.

PPPPPP=New master code

RRRRRR=Repeat the new master code

10 SSSSS EEEEE

11 SSSSS EEEEE

11 SSSSS EEEEE

SSSSS=Starting user address, EEEEE=Ending user address

SSSSS=Starting card number

EEEEE=Ending card number

SSSSS=Starting user address

EEEEE=Ending user address

Access mode: Card or PIN ; UUUUU=user address; 12 UUUUU PPPP

13 UUUUU PPPP

PPPP=4-digit pass code 0001~9999

Access mode: Card and PIN ; UUUUU=user address;

PPPP=4-digit pass code 0001~9999

TTT=Arming output time; 000~250=0~2.5 sec.

14 TTT

15 PPPP

PPPP=4-digit pass code (default value= 4321 )

P.S. Duress code will be unavailable and become a public PIN at access mode “ Card or PIN ” of M6

16 UUUUU SSSSSCCCCC

17 PPPP

UUUUU= User address; SSSSS=5-digit site code; CCCCC=5-digit card code

PPPP=4-digit pass code ( default value= 1234 ; disable Arming PWD= 0000 )

P.S. Arming PWD code will be unavailable and become a public PIN at access mode “ Card PIN ” and of M6

18 TTT

19 UUUUU QQQQQ

TTT=Door open waiting time: 001~600=1~600 sec.; default value: 15 sec.

UUUUU=User address;

QQQQQ=Card quantity( 00001 =Continuously inducting)

Please refer to function default value for details.

20 DDD

21 UUUUU S FFFFFFFF

22 N

23 NNN TTT

24 DDD

25 YYMMDDHHmmss

26 SSSSS EEEEE N

UUUUU=User address, S=4 sets of lift control(0~3); FFFFFFFF=8 assigned floor

(F=0: Disable, 1: Enable)

N=0(Delete tag); N=1(Add tag)

NNN=site number, TTT= relay time: 000~600=1~600 sec.

Please refer to function default value for details.

YYMMDDHHmmss: Year/ Month/ Day/ Hour/ Min./ Sec.

SSSSS=Starting user address; EEEEE=Ending user address;

N=0/Enable; N=1/Disable; N=2/Initial

UUUUU=User Address; FF=Floor (01~32 floor) 27 UUUUU FF

28 DDD

29 29

34 128 (321H/721H/725H/757H)

34 064 (331H) 34 000 (Disable)

Please refer to function default value for details.

controller is connected with AR-721RB.

Mode

M4/M6/M8

M4//M6M8

M4/M8

M4/M8

M4/M8

M4/M8

M4/M6M8

M4/M6/M8

M4/M6/M8

M4/M6/M8

M4/M6/M8

M4/M8

M4/M6/M8

M4/M6/M8

M4/M6/M8

M6

M4/M8

M4/M8

M4/M8

M4/M8

M4/M6/M8

M4/M8

M4/M6/M8

M4/M6/M8

M4/M8

M4/M6/M8

M4/M8

M6

M4/M8

M4/M6/M8

M4/M6/M8

M4/M8

M4/M8

M4/M6/M8

M4/M6/M8

M4/M6/M8