advertisement
IMPORTANT FOR FUTURE REFERENCE
Please complete this information and retain this manual for the life of the equipment:
Model #: ___________________________
Serial #: ___________________________
Date Purchased: ____________________
Installation & Operation Manual
REDUCED OIL VOLUME
FRYING SYSTEM
Covering
Models
SSHLV14, SSHLV184 SERIES
D
E S I G N
C
E
R
T I F
I
E
D C E R T I F I E D
L20-407 rev. 4 (011/16)
TO THE PURCHASER, OWNER AND STORE MANAGER
Please review these warnings prior to posting them in a prominent location for reference.
TO THE PURCHASER
Post in a prominent location the instructions to be followed in the event that an operator smells gas. Obtain this information from your local gas supplier.
FOR YOUR PROTECTION
DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
Do not spray aerosols in the vicinity of this appliance when it is in operation.
WARNING
Improper installation, adjustment, operation, alteration, service or maintenance can cause property damage, injury or death.
Read the installation, operating and maintenance instructions thoroughly before installing, operation, servicing this appliance.
WARNING
Installation, maintenance and repairs should be performed by a
Pitco Authorized Service and Parts (ASAP) company technician or other qualified personnel. Installation, maintenance or repairs by an unauthorized and unqualified personnel will void the warranty.
WARNING
Installation and all connections must be made according to local codes in force. In the absence of local codes in North
America, the installation must conform with the National Fuel
Gas Code, ANSI Z223.1/NFPA 54 or the Natural Gas and
Propane Installation Code CSA B149.1 as applicable. In
Australia, the appliance must be installed in compliance with
AS/NZS 5601.
WARNING
During the warranty period if a customer elects to use a nonoriginal part or modifies an original part purchased from Pitco and/or its Authorized Service and Parts (ASAP) companies, this warranty will be void. In addition, Pitco and its affiliates will not be liable for any claims, damages or expenses incurred by the customer which arises directly or indirectly, in whole or in part, due to the installation of any modified part and/or received from an unauthorized service center.
WARNING
This appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian
Electrical Code, CSA C22.2, as applicable and the hose must comply with AS/NZS 1869 and be class B or D.
WARNING
Adequate means must be provided to LIMIT the movement or this appliance without depending on the gas or electrical cord connection. Single appliances equipped with legs must be stabilized by installing anchor straps. All appliances equipped with casters must be stabilized by installing restraining chains.
WARNING
An appliance equipped with casters and a flexible gas line must be connected to the gas supply with a quick disconnect device.
In North America this quick disconnect must comply with ANSI
Z24.41. In Australia, the quick disconnect must comply with AS
4627.
WARNING
DO NOT alter or remove structural material on the appliance to accommodate placement under a ventilation hood.
WARNING
If the appliance is equipped with a power cord and it is damaged, it must be replaced by a Pitco Authorized Service and Parts
(ASAP) company technician, or a similarly qualified person in order to avoid a hazard.
WARNING
The power supply must be disconnected before servicing, maintaining or cleaning this appliance.
WARNING
The appliance is NOT jet stream approved. DO NOT clean the appliance with a water jet.
WARNING
DO NOT attempt to move this appliance or transfer hot liquids from one container to another when the unit is at operating temperature or filled with hot liquids. Serious personal injury could result if skin comes in contact with the hot surfaces or liquids.
WARNING
DO NOT use an open flame to check for gas leaks!
WARNING
DO NOT sit or stand on this appliance. The appliance’s front panel, tank, splash back, tank cover, workshelf, drain board is not a step. Serious injury could result from slipping, falling or contact with hot liquids.
WARNING
NEVER use the appliance as a step for cleaning or accessing the ventilation hood. Serious injury could result from slips, trips or from contacting hot liquids.
WARNING
The oil/shortening level should NOT fall below the minimum indicated level line at any time. The use of old shortening can be dangerous as it will have a reduced flash point and be more prone to surge boiling.
WARNING
The contents of the crumb catch and/or filter pan of any filter system must be emptied into a fireproof container at the end of the frying operation each day. Some food particles can spontaneously combust into flames if left soaking in certain oil/shortening materials.
WARNING
Completely shut the appliance down when shortening/oil is being drained from the appliance. This will prevent the appliance from heating up during the draining and filling process. Serious injury can occur.
WARNING
This appliance is intended for indoor use only.
WARNING
DO NOT operate appliance unless all panels and access covers are attached correctly.
WARNING
It is recommended that this appliance be inspected by a qualified service technician for proper performance and operation on a yearly basis.
WARNING
There is an open flame inside this appliance. The unit may get hot enough to set nearby materials on fire. Keep the area around the appliance free from combustibles.
WARNING
DO NOT supply the appliance with a gas that is not indicated on the data plate. If you need to convert the appliance to another type of fuel, contact your dealer.
WARNING
If gas flow to appliance is interrupted, or pilots extinguish, wait 5 minutes before attempting to relight the pilot to allow any residual gas in appliance to dissipate.
WARNING
Ensure that the appliance can get enough air to keep the flame burning correctly. If the flame is starved for air, it can give off a dangerous carbon monoxide gas. Carbon monoxide is a clear odorless gas that can cause suffocation.
WARNING
Never add oil to the appliance when it is at operating temperature. Splashing hot oil can cause severe injuries.
WARNING
Never add water to hot oil. Violent boiling can occur causing severe injury.
WARNING
This appliance is intended for professional use only and should be operated by fully trained and qualified personnel.
WARNING
. To avoid splashing of hot liquid when installed, this fryer must be restrained either in the manner of installation, or with adequate ties to prevent tipping.
WARNING
In North America, gas appliances equipped with casters must be installed with connectors that comply with the Standard for
Connectors for Movable Gas Appliances, ANSI Z21.69.CSA
6.16 Latest Edition. This connection should include a quick disconnect device that complies with the Standard for Quick
Disconnect Devices for Use With Gas Fuel ANSI Z21.41.CSA
6.9 Latest Edition. In Australia, an appliance equipped with casters and a flexible gas line must be connected to the gas supply with a quick disconnect device that complies with AS
4627 and a restraining cable. The restraining cable must not exceed 80% of the length of the flexible gas line. ii L20-407 rev.4 (011/16)
INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL
1.
THEORY OF OPERATION .............................................................................................................................
5
2.
INSTALLATION ...........................................................................................................................................
6
2.1.
2.2.
2.3.
2.4.
2.5.
2.6.
2.7.
CHECKING AND UNPACKING YOUR NEW APPLIANCE ..........................................................................
6
INSTALLATION CLEARANCES .................................................................................................................
6
LEVELING THE FRYER – LEGS/CASTERS .................................................................................................
7
GAS CONNECTION ................................................................................................................................
8
QUICK DISCONNECT CONNECTION .......................................................................................................
9
FUEL SUPPLY LINE LEAK AND PRESSURE TESTING ................................................................................
9
INSTALLATION SETUP ...........................................................................................................................
9
2.8.
2.9.
ELECTRICAL CONNECTIONS ................................................................................................................
10
VENTILATION AND FIRE SAFETY SYSTEMS ..........................................................................................
10
2.10.
INSPECTION ........................................................................................................................................
11
2.11.
INITIAL ADJUSTMENTS ........................................................................................................................
12
2.11.1.
FILLING THE APPLIANCE ......................................................................................................................
12
2.11.2.
LIGHTING INSTRUCTIONS ...................................................................................................................
12
2.11.3.
PILOT FLAME ADJUSTMENT ................................................................................................................
13
2.11.4.
MAIN BURNER SYSTEM ADJUSTMENT ................................................................................................
13
2.12.
INITIAL CLEANING ...............................................................................................................................
14
3.
OPERATION ..............................................................................................................................................
15
3.1.
3.2.
3.3.
3.4.
OPERATIONAL FEATURES ...................................................................................................................
15
BASIC OPERATIONAL FEATURES .........................................................................................................
16
FILLING THE FRY POT ..........................................................................................................................
17
FILLING THE TANK WITH LIQUID SHORTENING ..................................................................................
17
4.
APPLIANCE START UP ...............................................................................................................................
18
4.1.
4.2.
4.3.
COOKING ............................................................................................................................................
19
COOKING TIPS .....................................................................................................................................
19
BASKET LIFT OPERATION ....................................................................................................................
19
5.
FRESH OIL TOP OFF FUNCTION ..................................................................................................................
19
6.
AUTOMATIC OIL TOP OFF SYSTEM (OPTION) .............................................................................................
19
7.
QUICK STRAIN FILTERING ..........................................................................................................................
20
7.1.
7.2
NON ‐ AUTO FILTER MODELS ...............................................................................................................
20
AUTO FILTER MODELS ........................................................................................................................
20
8.
APPLIANCE SHUTDOWN............................................................................................................................
21
8.1.
8.2.
STANDBY MODE .................................................................................................................................
21
COMPLETE SHUTDOWN .....................................................................................................................
21
9.
PREVENTATIVE MAINTENANCE .................................................................................................................
21
9.1.
DAILY PREVENTATIVE MAINTENANCE ................................................................................................
21
9.1.1.
DAILY CLEANING .................................................................................................................................
21
9.1.2.
REPLACING THE FILTER MEDIA (if equipped) ......................................................................................
22
9.1.3.
APPLIANCE INSPECTION ......................................................................................................................
23
9.1.4.
CLEANING THE COOK TANK ................................................................................................................
23
9.1.5.
CLEANING THE CABINET .....................................................................................................................
23
9.1.6.
FILTER CLEANING (If Equipped) ...........................................................................................................
23
L20-407 rev.4 (011/16) 3
INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL
9.2.
WEEKLY PREVENTATIVE MAINTENANCE ............................................................................................
24
9.3.
MONTHLY PREVENTATIVE MAINTENANCE .........................................................................................
24
9.3.1.
BOIL OUT PROCEDURE ........................................................................................................................
24
9.3.2.
TEMPERATURE CHECK ........................................................................................................................
25
9.4.
ANNUAL/PERIODIC PREVENTATIVE MAINTENANCE AND INSPECTION ..............................................
26
9.4.1.
Safety Evaluation ................................................................................................................................
26
9.4.2.
Mechanical Inspection ........................................................................................................................
26
9.4.3.
Temperature Control System ..............................................................................................................
26
9.4.4.
Filter System (If Equipped) ..................................................................................................................
26
9.4.5.
GAS COMBUSTION SYSTEM ................................................................................................................
27
9.5.
VENTILATION HOOD ...........................................................................................................................
27
10.
TROUBLESHOOTING ...............................................................................................................................
28
10.1.
POWER FAILURE .................................................................................................................................
28
10.2.
HIGH TEMPERATURE LIMIT SWITCH ...................................................................................................
28
10.3.
DRAIN VALVE INTERLOCK ...................................................................................................................
28
10.4.
SELF CLEANING BURNER SYSTEM .......................................................................................................
29
10.5.
RESETTING THE SELF CLEANING BURNER ROLL OUT SWITCH ............................................................
29
10.6.
TROUBLESHOOTING CHARTS ..............................................................................................................
30
10.6.1.
Fryer Troubleshooting Chart ...............................................................................................................
30
10.6.2.
Filter Troubleshooting Chart (if equipped) ..........................................................................................
30
10.6.3.
COMPUTER CONTROLLER DISPLAYS ...................................................................................................
31
4 L20-407 rev.4 (011/16)
INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL
1. THEORY OF OPERATION
The Pitco Reduced Oil Volume fryer works very similarly to the standard Pitco SG/SSH fryer.
The Reduced Oil Volume Fryer has a reduced cold zone to significantly reduce oil usage and extend oil life. This smaller zone may require more frequent filtering depending on the product being fried.
Upon turning the fryer on, the high limit closes the (side on) safety relay which stays closed until the fryer is turned off. If the oil temperature exceeds 450 degrees F, the high limit opens and prevents further operation until the cooking oil has reached a safe cooking temperature. This places a minimum duty cycle on the safety (side on) relay to insure its proper operation when needed. The “heat demand” relay opens and closes on demand from the primary control to maintain the desired cooking temperature. When the “heat demand” relay closes, it energizes the main burners in the fry pot. Near the fryer pot heat tubes, the temperature probe and high limit can be found. The temperature probe provides a signal to the primary control, sensing the oil temperature in the fry pot.
The fryer is equipped with a manual “ADD OIL” function that can transfer fresh oil from a
JIB (Jug in Box) located under the fryer or a bulk oil management system. The operator can use this function as needed to replenish any oil consumed in the cooking process. It is recommended that oil only be added when the fry pot is at the desired temperature, and that the “ADD OIL” button not be used to fill an empty fry pot from the JIB.
Optional Automatic Top Off: If equipped, the fryer (only when operating at desired temperature) senses the oil level and replenishes consumed oil only if the display shows ready. There are no programming options for the operator or service technician, the control functions like any other Pitco computer control. The “ADD OIL” button
(described above) is present with Auto Top Off.
L20-407 rev.4 (011/16) 5
INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL
2. INSTALLATION
2.1. CHECKING AND UNPACKING YOUR NEW APPLIANCE
Your new Pitco appliance has been carefully packed into one crate. Every effort has been made to ensure that it is delivered to you in perfect condition. Pitco does not assume responsibility for damage or loss incurred in transit.
1. Upon Delivery, inspect for visible shipping damage in the presence of the trucking operator. If something appears damaged, file a claim for damages regardless of extent.
2. Unpack and inspect unit for damage. Contact the shipper within 15 days and file a concealed damage claim; the shipper is only responsible for concealed damage for 15 days after delivery.
3. Remove the unit from the shipping pallet: a: Remove the filter pan, and JIB pan from unit before attempting to
dismount the unit from the shipping base.
4. Do not allow the full weight of the unit to rest on the legs or caster when removing the appliance from the shipping pallet. The casters can be bent or damaged if too much weight or force is applied to them from improper handling.
5. Check the packing list enclosed with your appliance to ensure that you have received all the parts to the appliance. If you are missing any parts, contact the dealer from whom the appliance was purchased.
6. Using the front cover of this manual, record the following for warranty service or future reference:
1. Your Pitco model number.
2. Fryer serial numbers (Found on the inner door of each fryer).
3. The date purchased from your dealer invoice.
Once you have completed the above, the appliance is ready to be installed.
CLEARANCES
The clearances shown below are for combustible and non-combustible installations and will allow for safe and proper operation of your appliance.
Combustible Construction Non-Combustible Construction
Inches (centimeters)
Back
Sides
Floor
6.0" (15.2cm)
6.0" (15.2cm)
9” (22.86 cm)
0.0" (0.0cm)
0.0" (0.0cm)
9” (22.86 cm)
In addition to the above clearances there must also be at least 30 inches (76.2cm) of aisle space in front of the appliance.
WARNING
Leave at least 18 inches (47cm) of open space between the flue of the appliance and the intake of the exhaust hood. Failure to do so could result in improper operation of the appliance.
WARNING
DO NOT obstruct the flow of ventilation air openings around the appliance. Adequate clearance around the appliance is necessary for servicing and proper component ventilation. Ensure that you meet the minimum clearance requirements specified in this manual.
WARNING
DO NOT install this appliance next to a water cooker, or use it in any way in which water can come in contact with the hot oil. Splash over of water into hot oil may result in a steam eruption, potentially causing hot oil to be ejected from the fryer, and creating a burn hazard.
6 L20-407 rev.4 (011/16)
INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL
2.3. LEVELING THE FRYER – LEGS/CASTERS
CAUTION
To prevent equipment damage and/or personal injury, do not tilt the appliance onto any two of its casters or legs, or pull the appliance by the splash back .
WARNING
This appliance must be installed with the legs or casters provided by the manufacturer.
WARNING
DO NOT perform leveling procedure when appliance is in operation or full of hot liquids. Serious injury could result.
When you receive your appliance, it is completely assembled with legs or optional casters. This appliance must be installed with legs or casters; it cannot be curb mounted, or sealed to a base.
Curb mounting will seriously inhibit this appliance’s ability to effect proper component ventilation.
The supplied legs or casters provide the necessary height to meet sanitation requirements and assure adequate air supply for electrical component ventilation. To level the fryer, use the following procedure.
Required tools: Large pair of water pump pliers, Medium flat blade screwdriver, level 12” (30.5 cm) long max.
1 Position appliance in final installed location.
2 Apply level across front, and then the left and right side of unit, determine lowest point, and distance to level.
3 Add the distance determined in step 2 to caster or leg on the lowest corner of appliance. a. Swivel casters- loosen 2 set screws (A) b. Legs and swivel casters-. Adjust the height of the leg / caster by turning adjustment collar/ foot (B) with water pump pliers until desired change in height is achieved.
Swivel casters only: Retighten set screws (A). c. Fixed casters- Adjust height by moving wheel and axle to alternate holes (D) in wheel bracket higher or lower as needed. Refer to “FIXED” type caster in Figure 3.
4 Adjust remaining casters or legs as needed to insure the appliance is supported evenly at each caster/leg contact point.
Figure 3 Caster and leg types
L20-407 rev.4 (011/16) 7
INSTALLATION & OPERATIONAL SSHLV MANUAL
EU GASTECHNICAL INFORMATION
Applicable Countries
AT, BG, CH, CZ, DK, EE, FI, GB, GR, HU, IE, IT,
LT, LV, NO, PL, PT, RO, ES, SI, SK, SE, TR
LU
FR
BE
DE
NL
BG, CH, CY, CZ, FR, DE, GB, GR, HU, IE, IT,
LU, MT, NL, PL, PT, RO, ES, SI, SK, TR
SSHLV14
AT, BG, CH, CZ, DK, EE, FI, GB, GR, HU, IE, IT,
LT, LV, NO, PL, PT, RO, ES, SI, SK, SE, TR
LU
FR
B E
DE
NL
BG, CH, CY, CZ, FR, DE, GB, GR, HU, IE, IT,
LU, MT, NL, PL, PT, RO, ES, SI, SK, TR
AT, BG, CH, CZ, DK, EE, FI, GB, GR, HU, IE, IT,
LT, LV, NO, PL, PT, RO, ES, SI, SK, SE, TR
SSHLV14T
LU
FR
BE
DE
NL
BG, CH, CY, CZ, FR, DE, GB, GR, HU, IE, IT,
LU, MT, NL, PL, PT, RO, ES, SI, SK, TR
SSHLV184
Nat
LP
G20
G20/G25
G20/G25
G25
G31
I
2H
I
2E
I
2ESI
I
2E+
I
2ELL
I
2EK
I
3P
Nat
LP
Nat
LP
G20
G20/G25
G20/G25
G25
G31
I
2H
I
2E
I
2ESI
I
2E+
I
2ELL
I
2EK
I
3P
G20
G20/G25
G20/G25
G25
G31
I
2H
I
2E
I
2ESI
I
2E+
I
2ELL
I
2EK
I
3P
21
21
21
20
18.9
19.3
20/25
25
50/37
10
25.4
1.9 m m
N22
1.9/2.15 m m
2.15 m m
#56 LP16
20
18.9
19.3
20/25
25
50/37
10
25.4
1.9 m m
N22
1.9mm /#45
#45
#56 LP16
20
18.9
19.3
20/25
25
50/37
10
25.4
1.9 m m
N22
1.9/2.15 m m
2.15 m m
#56 LP16
YES 2.0
NO
YES
YES
YES
2.0/2.3
2.3
0.8
YES 2.0
NO
YES
YES
YES
2.0/2.3
2.3
0.8
YES
NO
YES
YES
YES
2.0
2.0/2.3
2.3
0.8
8
Your gas appliance will give you peak performance when the gas supply line is of sufficient size to provide the correct gas pressure. The gas line must be installed to meet the local building codes or
National Fuel Gas Code ANSI Z223.1 Latest Edition. In Canada, install the appliance in accordance with CAN/CGA-B149.1 or .2 and local codes. In Australia, install the appliance in accordance with
AS/NZS 5601. Gas line sizing requirements can be determined by your local gas company or, in North
America, by referring to the National Fuel Gas Code, Appendix C, Table C-4 (for natural gas) and
Table C-16 (for propane). The gas line needs to be large enough to supply the necessary amount of fuel to all appliances without losing pressure to any appliance.
A properly sized and installed gas line will deliver a supply pressure between 7.0” W.C. (17.4mbars,
1.74kPa) and 10.0” W.C. (24.9mbars, 2.49kPa) natural gas or between 11.0” W.C. (27.4mbars,
2.74kPa) and 13.0” W.C. (32.4mbars, 3.25kPa) for propane to all appliances connected to the supply line, operating simultaneously at full demand. The pressure at the gas valve shall not exceed ½ PSI
(13.84 “WC, 34.5 mbar, 3.45 kPa). The gas supply connection to this appliance is located in the rear of the appliance approximately 10-1/2” (26.7 cm) from the floor of the appliance when legs are used.
Each appliance is equipped to operate on one certain fuel type. The type of fuel with which the appliance is intended to operate is stamped on the data plate, which is attached to the inside of the door.
WARNING
NEVER supply the appliance with a gas other than the one that is indicated on the data plate. Using the incorrect gas type will cause improper operation and could result in serious injury or death. If you need to convert the appliance to another type of fuel, contact the dealer you purchased it from.
NOTICE
NEVER use an adapter to make a smaller gas supply line fit the appliance connection. This may not allow proper gas flow for optimum burner operation, resulting in poor performance and improper operation.
L20-407 rev.4 (011/16)
INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL
2.5. QUICK DISCONNECT CONNECTION
In North America, gas appliances equipped with casters must be installed with connectors that comply with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69.CSA 6.16
Latest Edition. This connection should include a quick disconnect device that complies with the
Standard for Quick Disconnect Devices for Use With Gas Fuel Appliances ANSI Z21.41.CSA 6.9
Latest Edition. In Australia, an appliance equipped with casters and a flexible gas line must be connected to the gas supply with a quick disconnect device that complies with AS 4627 and a restraining cable. The restraining cable must not exceed 80% of the length of the flexible gas line.
The restraining device should be attached to the appliance at the back panel.
2.6. FUEL SUPPLY LINE LEAK AND PRESSURE TESTING
The fuel supply system must be tested before the appliance is used. If the fuel line is going to be tested at a pressure greater than ½ PISG (3.45 kPa, 34.5 mbar), insure that that appliance is disconnected from the fuel line. If the fuel line is to be tested at a pressure equal to or less than ½
PSIG (3.45 kPa, 34.5 mbar), the appliance can be connected during the test, but the unit’s gas valve must be shut. Test all gas line connections for leaks with a solution of soap and water when pressure applied.
Setup
The installation of this appliance MUST conform to local codes. In the absence of local codes in
North America, the installation must conform with the National Fuel Gas Code, ANSI Z223.1/NFPA
54 or the Natural Gas and Propane Installation Code CSA B149.1 as applicable. In Australia, the appliance must be installed in compliance with AS/NZS 5601 (current revision)
L20-407 rev.4 (011/16) 9
INSTALLATION & OPERATIONAL SSHLV MANUAL
CONNECTIONS
It is advised that this power supply be plugged into a wall receptacle that is controlled by the ventilation control. This will prevent the appliance from being operated without the ventilator on. If your appliance requires an electrical connection, the power requirements are listed below.
A full version of the wiring diagram can be found adhered to the inner door(s) of the appliance.
North America International
Input Voltage
Current per unit
120 VAC, 50/60 Hz 220, 230 or 240 VAC 50/60 Hz
1.0 Amp 0.5 Amps
Filter Current 7.5 Amp 4.2 Amps the warranty.
CAUTION
Connecting the appliance to the wrong power supply may damage the appliance and void
WARNING
This appliance must be connected to a power supply having the same voltage and phase as specified on the data plate located on the inside of the appliance door.
WARNING
DO NOT attempt to connect the appliance to an electrical supply other than that indicated on the data plate. Electrical connection should be performed by qualified personnel.
WARNING
The electrical connection used by this appliance must comply with local codes. In the
United States if there are no local codes that apply, refer to the National Electrical Code
(NEC), ANSI/NFPA 70 for installation in the US. In Canada, refer to CSA Standard C22.2 and local codes. In all other cases, refer to local and national codes and regulations.
WARNING
If your appliance is equipped with an oil proof, electrical supply cord with a three-prong safety plug. This is to protect operators from electrical shock hazard in the event of an equipment malfunction. DO NOT cut or remove the grounding (third) prong from this plug; it should be plugged into a properly grounded three-prong receptacle.
2.9. VENTILATION AND FIRE SAFETY SYSTEMS
Your new appliance must have proper ventilation to function safely and properly. Exhaust gas temperatures can reach as high as 1100 °F (593 °C). Therefore, it is very important to install a fire safety system. Your ventilation system should be designed to allow for easy cleaning. Frequent cleaning and proper maintenance of the ventilation system and the appliance will reduce the chances of fire. Ventilation and fire safety systems must comply to local and national codes for US and Canada.
Refer to ANSI 83.11 for a list of reference documents that will provide guidance on ventilation and fire safety systems. For installations in U.S. and Canada, additional information can be obtained from
CSA International, 8501 East Pleasant Valley Road, Cleveland, OH, 44131 or visit their website at www.csa-international.org. In Australia the ventilation system must comply with AS/NZS 5601.0.
It is essential that the appliance be operated only when adequate ventilation is provided. Your ventilation hood should be properly maintained. A qualified installation professional should ensure that the hood is operating properly in conjunction with the appliance. Inadequate ventilation may not properly evacuate all appliance emissions. Excessive or unbalanced ventilation may cause drafts, which could interfere with proper operation of the pilot and burners. Leave at least 18 inches (47cm) of open space between the flue of the appliance and the intake of the exhaust hood.
10 L20-407 rev.4 (011/16)
INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL
WARNING
Ensure that your ventilation system does not cause a down draft at the appliance’s flue opening. A down draft will not allow the appliance to exhaust properly and will cause overheating, which may cause permanent damage. Damage caused by down drafts will not be covered by the warranty. NEVER allow anything to obstruct the flow of combustibles or ventilation exiting the appliance. NEVER place anything on top of the flue area, or block the flue in any way. Never place a grease condensing drip pan over the flue opening.
WARNING
NEVER connect the ventilation blower or hood directly to the flue of this appliance. The resulting increased flow of air through the combustion system will cause improper operation, poor temperature recovery, poor ignition and could extinguish the pilot.
WARNING
Replacing or adding appliances under a pre-existing fire safety system may require modifications to the system. ALWAYS contact a professional who is qualified in installing, designing and maintaining your fire safety system to assure that any appliances located under the fire safety system are adequately protected.
For Australia, the fryer must be installed in accordance with AS/NZS 5601, local authority and any other relevant statutory regulations. Flexible hose (if used) must comply with AS/NZS 1869 Class B or D, be of appropriate internal diameter, be kept as short as possible (not exceed 1.2 meters), must not be kinked and not be in contact with a hot surface. A chain must be fitted to restrict the fryer movement to no more than 80% of the hose length.
2.10. INSPECTION
Before you begin filling and adjusting the appliance, perform the following visual checks:
After the appliance is in its permanent location, check the levelness. Any additional leveling that is necessary can be performed as previously described.
Ensure that the sensing probe and high temperature limit bulb are in place and secure. Check the high limit bulb mounting screws to ensure that they are tight.
Review the installation portion of this manual and ensure that all steps have been followed and executed properly.
1) Probe
2) High Temperature Limit
L20-407 rev.4 (011/16) 11
INSTALLATION & OPERATIONAL SSHLV MANUAL
After your appliance has been properly installed as described in the installation section of this manual, it will need to be adjusted to ensure that it will perform as designed. A qualified person must perform these adjustments.
To perform these adjustments the following tools will be needed:
Manometer
Digital Thermometer (Temperature Probe)
DC
Microammeter
DC
2.11.1. FILLING THE APPLIANCE
Refer to the following procedure to fill the cook tank prior to operation.
1. Ensure that the drain valve is closed.
2. Fill the tank to about ½” (1.25 cm) below the oil level line with oil/shortening. The oil/shortening level will rise slightly as it heats up. Never let the oil/shortening level go below the MIN LEVEL mark stamped on the tank.
WARNING
Oil/shortening must completely cover the heat tubes at all times while appliance is on.
CAUTION
This appliance is not designed for cooking with water. Fill with oil/shortening only.
WARNING
During operation there is an open flame inside this appliance. The unit may get hot enough to set nearby materials on fire. Keep the area around the appliance free from combustibles.
2.11.2. LIGHTING INSTRUCTIONS
There is nothing to manually light on the SSHLV system. Pilot ignition is performed and controlled by the electronic ignition system. Refer to the following instructions to light the appliance.
1. Verify that all electrical connections, clearances, gas connections, ventilation requirements and gas pressures have been properly implemented, tested, adjusted and checked for compliance in accordance with the instructions and requirements in Section 2 of this document prior to proceeding.
2. Open the gas supply valves to the appliance.
3. Turn the gas valve knob to the ON position.
4. Turn the controller on. Press the button to turn the COMPUTER on.
5. The main burners will light and be controlled by the computer.
Note: If your appliance has a self cleaning burner system, the burners may make a popping sound immediately after the main burners light during startup. This noise during startup is part of the normal operation of the self cleaning burner system and should NOT continue during normal cooking & idle periods. (SCB Only)
12 L20-407 rev.4 (011/16)
INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL
WARNING
Do not store flammable materials in or near this appliance. Do not spray aerosols in the vicinity of this appliance while it is in operation. Contact a qualified service person or the factory, using the information on the back of this manual, if the appliance produces unusual odor, yellow tipping flames or is not performing as per the original installation.
2.11.3. PILOT FLAME ADJUSTMENT
Perform this procedure with the pilot lit.
Note: This procedure requires the use of a DC microammeter.
1. Connect the DC microammeter between the flame sensor terminal and the flame sensor lead. Observe proper polarity: if the meter needle goes below 0, reverse the leads. The current reading must be or 0.15 A or greater.
2. Adjust the current reading to the required level by adjusting the pilot flame.
Remove the pilot adjustment screw cap to expose the pilot adjustment screw.
Turning the pilot adjustment screw clockwise will decrease the size of the pilot flame and flame sense current. Turning the pilot adjustment screw counterclockwise will increase the pilot flame size and the flame sense current.
3. Rotate the screw in the direction needed to achieve a reading of 0.15 A or greater.
Note: Allow 3 to 5 minutes between flame adjustments to allow the reading stabilize.
4. Once the pilot flame has been adjusted properly, replace the pilot adjustment screw cap screw and remove the microammeter.
2.11.4. MAIN BURNER SYSTEM ADJUSTMENT
For the main burners to operate the gas supply valve must be open and the main power button on the computer must be pressed. The main burners receive gas from the main gas supply through the thermostatically controlled valve. When the oil temperature drops below the preset temperature the gas control valve opens.
The main burners must be adjusted to deliver optimum flame. Refer to the following procedure to adjust the main burners. to
1. Ensure that the main gas valve is shut off, remove the burner pressure tap plug and connect an accurate pressure gauge (range of 0-16 “W.C. (39.85mbar, 3.98kPa) in 0.1” (.25mbar,
.02kPa) increments) or manometer.
2. Turn on this and all appliances connected to the gas supply line and light their main burners.
The pressure reading of the installed pressure gauge should not drop from the required installation pressure. Any loss of pressure indicates inadequate supply line installation, which will cause poor performance of all appliances during peak usage.
3. The installed pressure gauge should be the same, ±0.1” W.C. (.25mbar, .02kPa), as that marked on the data plate on the inside door of the appliance. If the pressure is correct, go to step 6, if it is not, adjust the pressure as outlined in step 4.
4. To adjust the pressure, remove the burner pressure adjustment screw cap and, with a flat head screwdriver, adjust the regulator screw until the proper burner pressure is reached.
Turning the screw clockwise will increase the burner pressure. Turning the screw counterclockwise will decrease the burner pressure. When the pressure is correct, replace the regulator adjustment screw cover.
L20-407 rev.4 (011/16) 13
INSTALLATION & OPERATIONAL SSHLV MANUAL
5. Turn off ALL appliances, shut the main gas valve to your Pitco appliance and remove the pressure gauge. Apply pipe joint compound to the manifold pressure tap plug and reinstall it.
6. Check for leaks at the pressure tap fitting.
CAUTION
Be careful not to disturb the probe and high temperature limit bulb and capillary during operation and cleaning of this appliance.
CLEANING
When your appliance is shipped, many of its parts are covered with a thin coat of oil for protection.
Before the appliance is ready for cooking all transit material must be removed and the appliance must be cleaned. This will remove the oil coating and any foreign matter that may have accumulated during storage and shipment. Refer to the following procedure to clean the appliance.
WARNING
Wear protective gloves and clothing when cleaning and draining the appliance and when disposing of water. The water is extremely hot and can cause severe injuries.
CAUTION
DO NOT leave the appliance unattended during cleaning. Never let the liquid level go below the heat tubes.
NOTICE
DO NOT run water through the filter return system. This will damage the pump and void your warranty.
1. Read the “operation” section of this manual prior to filling or operating the appliance.
2. The following steps should be followed using a food grade cleaner.
WARNING
Use a commercial grade cleaner formulated to effectively clean and sanitize food contact surfaces. Read the directions and precautionary statements before use.
Particular attention must be paid to the concentration of cleaner and the length of time the cleaner remains on the food contact surfaces.
3. Following the cleaning directions in this manual to clean the tank interior and all other food contact surfaces.
4. When cleaning is complete, rinse the inside of the tank thoroughly with cool water. Continue to rinse the tank until the cleaner has been completely and thoroughly rinsed from the tank.
5. Using a clean dry cloth, wipe out all of the water in the fry tank.
6. Using a clean cloth and food grade cleaner, clean the bread and batter station and/or filter pan, if equipped.
14
If the appliance can’t be adjusted to operate properly contact a qualified service person or contact the factory using the contact information on the back of this manual.
L20-407 rev.4 (011/16)
INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL
3. OPERATION
An operator’s manual for your appliance’s specific control type should be included with this manual. Refer to that manual prior to operating this appliance.
WARNING
Before operating the fryer, check that tipping restraints or other features to prevent tipping are installed and mechanically sound. Splashing of hot liquid may occur if adequate means of securing the fryer in place are not used.
The diagram below outlines some of the key operational components of your appliance. Refer to the following sections of this manual to learn more about these features.
L20-407 rev.4 (011/16) 15
INSTALLATION & OPERATIONAL SSHLV MANUAL
3.2. Basic operational Features
1 . Basket Hanger - Holds fry baskets while draining or between loads. Lifts off for easy cleaning.
2. Fry pot oil top off supply jug Supplied by others, provides on board storage for fresh cooking oil.
3. Filter Pan Cover – Prevents debris from falling into filter pan when in use. Easily slides out for cleaning.
4. Filter Pan Assembly - Holds oil during frypot cleaning and filtering. Contains filter pick up assembly,
and pick up tube
5. Controller - Controls frypot temperature, provides cook time tracking and other functions.
6. Gas Valve Control Knob - Turns gas valve ON or OFF.
7. Filter Motor Thermal Overload Reset button (RED ) - Press to reset. SEE WARNING BELOW
8. Drain Outlet – Swings out to ease shortening disposal. CAUTION: Extremely HOT when in use.
9. Pump Strainer – Helps prevent debris from jamming filter pump if filter paper rips or is installed poorly.
10. Filter Pump Circuit Breaker Protects pump motor from over current. SEE WARNING BELOW
11. Frypot High Limit Reset Button (Shown on page 28) - Press to reset.
12. Data Plate Label – Displays operational specifications and other important information.
WARNING
Resetting either the filter pump circuit breaker or the filter pump motor thermal overload may cause unexpected hot oil discharge if a refill switch or flush hose valve (if equipped) is left in the
ON position. Always verify the appliance is turned OFF and that the filter return switches, or the flush hose valves (if equipped) are OFF and safely positioned before resetting the breaker or thermal overload.
16 L20-407 rev.4 (011/16)
INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL
3.3. FILLING THE FRY POT
Only use shortening that is liquid at room temperature in this appliance.
CAUTION
This appliance is NOT designed for cooking with water. Cook with oil or shortening only.
WARNING
This appliance is not designed for use with solid shortening. Using solid shortening will cause the filter pump and oil lines to become plugged, and require professional service personnel to fix and will not be covered under the warranty.
3.4. FILLING THE TANK WITH LIQUID SHORTENING
To fill the tank with liquid shortening, refer to the following procedure.
OIL AND COOK LOAD CAPACITIES
FRYER MODEL
TANK (OIL)
CAPACITY*
LBS.
(kg)
COOK
CAPACITY**
LBS.
LOAD
(kg)
SSHLV14 30 (13.6)
SSHLV14T 17 (6.8
SSHLV184 43 (19.5)
1.5
(0.68)
1.5
(0.68)
2.5
(1.1)
* Per Tank ** Per Basket
It is recommended that high quality liquid frying oils be used for longest oil life.
1. Verify that the tank interior is clean and free of any construction debris.
2. Rinse the tank and drain line with a small amount of clean cooking oil.
3. Ensure that the drain valve is closed.
4. Fill the tank to about the oil level mark. The oil will expand when heated up, raising the level to OIL
LEVEL line.
5. After the cooking oil is at operating temperature, add oil to the frypots as needed to obtain the desired
operating level.
WARNING
THE PUSH BUTTON TOP OFF SYSTEM IS NOT INTENDED TO FILL FRY POTS
WARNING
.
Replace oil/shortening that is smoking, or foams when cooking. Old, heavily used oil/shortenings have reduced flash point, and are prone to surge boiling. Cooking with old, heavily used oil/shortening may create dangerous conditions.
WARNING
Do not overload the fry baskets, or allow the oil level to exceed the MAX line while cooking. Wet product, or too much oil in the frypot can lead to surge boiling, and over topping the frypot.
Overtopping may create hazards such as burns or slippery floors.
CAUTION
This appliance is NOT designed for cooking with water. Severe equipment damage will occur if a fryer is used as a water bath for rethermalizing foods. Damage of this type is not covered under the warranty
WARNING
Oil must completely cover the heating tubes at all times while appliance is on.
L20-407 rev.4 (011/16) 17
INSTALLATION & OPERATIONAL SSHLV MANUAL
4. APPLIANCE START UP
If the appliance is plugged in and has power the display will show
.
Refer to the following procedure to start the appliance prior to operation.
1. On manual (non-Auto Filter) models verify that the drain valve is closed by ensuring that the blue drain handle is pushed all the way in. Failure to do so may result in unsafe conditions.
2. Fill the cook tank with oil/shortening. (See section 3.3 “Filling the Cook Tank”). Never operate the appliance unless the cook tank is properly filled.
3. Press button to turn the controller on. Manual models will begin proper operation.
Auto-Filter models will display the prompt ‘ Is vat full ?’. Press the ‘YES’ key if the tank is full otherwise press the ‘NO’ key. Failure to accurately respond to this prompt may result in unsafe conditions.
Note: If your appliance has a self cleaning burner system, the burners may make a popping sound immediately after the main burners light during startup. This noise during startup is part of the normal operation of the self cleaning burner system and should NOT continue during normal cooking & idle periods.
4. The appliance is now on and heating the oil/shortening in the cook tank.
WARNING
NEVER operate the appliance with an empty fry tank. It will void the warranty.
WARNING
Oil/shortening level should NOT be allowed to fall below the indicated level line at any time. Dry firing of the fry tank will shorten tank service life and will void your warranty.
WARNING
Oil level should NOT be allowed to fall below the indicated level line at any time. Dry firing of the tank may cause a fire, and can shorten tank service life. Evidence of dry firing will void your warranty.
OIL TEMPERATURE
Keep the oil temperature in the fryer to a maximum of 190°C (374°F). Higher temperatures will cause rapid breakdown of the oil and give you no faster cooking. At 205°C (401°F) to 210°C (410°F) the life of the oil is only one third of its life at 190°C (374°F). In addition, increased decomposition causes the oil to smoke badly even if the temperature is lowered to 190°C (374°F) again. High temperatures give you no advantage, cost you money and increase the fire danger.
TEMPERATURE DELL’OLIO
Mantenere la temperatura dell’olio nella friggitrice fino a un massimo di 190°C. Temperature maggiori causano un rapido degrado dell’olio, senza tuttavia eseguire una cottura più rapida. Da 205°C a 210°C la durata dell’olio è inferiore di un terzo rispetto a quella a 190°C. Inoltre, l’accresciuta decomposizione comporta una forte emissione di fumo, anche se la temperatura viene riportata di nuovo a 190°C. Le alte temperature non prevedono vantaggi, sono antieconomiche e aumentano il rischio d’incendio.
ΘΕΡΜΟΚΡΑΣΙΑ ΛΑ∆ΙΟΥ
∆ιατηρείτε τη θερμοκρασία λαδιού στη φριτέζα μέχρι 1 90 βαθμούς Κελσίου . Υψηλότερες θερμοκρασίες
θα αλλάξουν τη σύνθεση του λαδιού πολύ σύντομα και δεν ψήνετε γρηγορότερα . Η δυναμικότητα του
λαδιού στους
205-2
1
0
βαθμούς Κελσίου είναι μόνο το ένα τρίτο της δυναμικότητάς του στους 1
90
βαθμούς Κελσίου
.
Επιπλέον η αυξημένη αποσύνθεση του λαδιού
,
σε θερμοκρασίες πάνω από 1
90
βαθμούς Κελσίου , κάνει το λάδι να καπνίζει άσχημα κι αν ακόμη κατεβάσετε τη θερμοκρασία κατόπιν
πάλι στους 1 90 βαθμούς Κελσίου . Οι υψηλές θερμοκρασίες δε σας παρέχουν κανένα πλεονέκτημα , σας
κοστίζει περισσότερα χρήματα και αυξάνουν τον κίνδυνο πυρκαγιάς .
18 L20-407 rev.4 (011/16)
INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL
4.1. COOKING
To ensure the quality of the food you cook in this appliance, follow the preparation instructions from the food manufacturer. When the appliance is not in use, the oil should be cooled and covered to prevent contamination.
WARNING
Dry fired heat tubes are extremely hot, will shorten the tank service life and will void your warranty.
tips
Always follow the food manufacturer’s directions.
The lower the oil temperature, the longer the cooking time and the greater the fat absorption.
NEVER overfill fryer baskets. Overfilling can result in soggy, greasy product.
Typical French Fry Cook Times (m:s)
When removing baskets from the cook tank, shake gently to remove excess oil.
Temperature
Fry Thickness (177°C) (182°C) (188°C)
Thin 2:45 2:15
Never leave a basket over the fryer. The heat from the cook tank will continue to cook the product.
Oil/shortening quality can affect product quality.
Keep salt and water away from the oil/shortening to maintain its life. Oil/shortening filtration removes crumbs from the oil which will also extend its life.
This table is for reference only. Please refer to the product manufacturer’s specifications to determine exact cook temperatures and times.
4.3. BASKET LIFT OPERATION
If the appliance is equipped with basket lifts, place the basket onto the basket lift prior to starting the timer(s). The basket(s) will be lowered into the cook tank when a product key is pressed. At the end of the preset cooking time, the basket lift will raise the basket out of the cook tank. Cancelling the cook by pressing and holding the cook timer button will raise the basket out of the oil. Cook timer keys L through 5 will operate the right-hand basket lift. Keys 6 through R will operate the left-hand basket lift.
5. FRESH OIL TOP OFF FUNCTION
To add fresh oil to the fry tank on demand, press and hold the key. Release the key when the desired oil level is reached in the tank.
Use the Left or Right key to top off the Left or Right vat, respectively for split vat models.
Manual top offs are not permitted while there is an active cook in process.
6. AUTOMATIC OIL TOP OFF SYSTEM (OPTION)
Pitco offers the “Automatic Oil Level Control” option (Auto-Top Off) to maintain the optimal oil level in your
Pitco fryer. This optional system minimizes the need for the operator’s attention during busy cooking hours. The system maintains oil levels in the frying vat by adding small amounts of fresh oil when appropriate. Replenishment oil is drawn from a Jug In Box (JIB) located in one of the cabinets in a multiple vat build. Alternately, the JIB can be remotely located within nine feet of the fryer. The system can also accommodate a bulk oil system if equipped.
There are specific conditions when fresh oil will not be added to the vat by the automatic system:
Cycle
2) Heating
Cycle
4) Filtering
5) Control in the “OFF” state
L20-407 rev.4 (011/16) 19
INSTALLATION & OPERATIONAL SSHLV MANUAL
7.
QUICK STRAIN FILTERING
When the controller indicates the need to perform a “Quick Filtering” as soon as business levels permit.
For more thorough filtering/cleaning operations refer to the Preventative maintenance section of this document or the separate controller manual that was provided with your appliance.
WARNING: Before filtering ensure that filter pan is in place and empty. Wear proper personal protective equipment while filtering.
1. With Fryer ON and oil above the filter temperature, Pull the BLUE drain handle to initiate filter prompting on the control. The controller will display ‘FILTER?’
2. PRESS the ‘YES’ key, then press the TANK FILL key to turn pump ON.
3. Follow the store procedures for cleaning and wait for the filter timer to end.
4. When filter timer ends, push the blue handle back in to close drain. The pump will refill the fry tank.
5. When bubbles appear in oil, press the TANK FILL key to turn pump to OFF.
6. FILTER ONLY ONE TANK AT A TIME, the filter pan may overflow.
7.2 AUTO FILTER MODELS
WARNING: Before filtering ensure that filter pan is in place and empty. Wear proper personal protective equipment while filtering.
1. Ensure that oil temperature is above Filter Temperature. Press the Filter button on the controller to initiate auto-filter prompting.
2. PRESS ‘YES’ key to begin auto-filter process and follow the prompts on the controller to continue the auto filter process.
3. Wait until the auto filter process completes.
4. When prompted by the controller, verify that the oil in the frypot has reached an appropriate level. If the filter pan is empty, press the ‘YES’ key to complete the filter process. If there is still oil in the filter pan, press the ‘NO’ key to run the pump for an additional 20 seconds.
NOTE: ‘NO’ may be selected for ‘Is vat full’ a maximum of three times. The fourth time that ‘NO’ is selected the fryer will turn OFF and display ‘POSSIBLE FILTER ISSUE – CHECK AND
RESOLVE’. Press the ‘YES’ key to acknowledge.
20 L20-407 rev.4 (011/16)
INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL
8. APPLIANCE SHUTDOWN
There are two shutdown modes of appliance operation: STANDBY and COMPLETE. The standby mode removes the ability of the appliances main burners to operate. Complete shutdown turns off the gas supply to the appliance. A STANDBY shutdown can be used during slow business periods.
ALWAYS perform a COMPLETE shut down when the appliance will not be in use and unsupervised for an extended period of time. Refer to the following procedures to enter the appropriate shutdown mode.
Press the button to turn the computer OFF.
1. Press the button to turn the computer OFF.
2. Turn the ON/OFF knob on the gas valve clockwise to the OFF position
3. The appliance is now completely shut down and can be cleaned if desired.
9. PREVENTATIVE MAINTENANCE
9.1. DAILY PREVENTATIVE MAINTENANCE
Performing the preventative maintenance steps below daily will keep your equipment safe and at peak performance. During the cooking process, oil/shortening may spill and splatter and requires immediate attention. Furthermore, during the cooking process, particles, crumbs and crackling collect inside the fry tank reducing product quality and decreasing oil/shortening life. If you are producing high quantities of fried food and/or frying heavily battered food, it will be necessary to perform these steps more than once a day.
WARNING
Serious injury could result from direct contact with hot surfaces and/or oil. Always wear apron, heat resistant gloves for skin protection and goggles for eye protection.
CLEANING
At least daily, a complete filter is required. Make sure a clean filter is installed every day.
For manual filtering refer to the following procedure:
1. Ensure that the filter pan is in place and empty. Turn the appliance OFF. Pull the blue drain handle to drain oil/shortening from the cooker tank into the filter pan.
2. Using a water dampened clean cloth, wipe the insides of the fry pot to remove crumbs and debris. Scrub crumb ring in frypot with abrasive pad if needed. REMOVE ALL MOISTURE from the tank before proceeding to the next step.
3. Press the minutes. key to turn the pump on. It is recommended to allow the oil to circulate for 5-10
4. To refill the tank, push the blue drain handle in. Ensure that the oil/shortening level is to the level line. Additional oil may need to be added to the cook tank
5. When the tank has completed filling, press the oil/shortening in the fryer is now filtered. key to deactivate the pump. The
7. Clean the filter pan and replace the filter media following the procedures mentioned in this manual.
For Automated Filtering, refer to the following procedure:
Ensure that the oil temperature is above allowable filter temperature and that the filter pan is properly in place and empty before performing this procedure.
1. Turn the fryer ‘OFF’.
2. Push and hold the key to enter the Fryer Control Menu.
WARNING - Ensure that the filter pan is in place and empty before proceeding. Failure to do this may result in an unsafe situation.
L20-407 rev.4 (011/16) 21
INSTALLATION & OPERATIONAL SSHLV MANUAL
3. Press the #1 key. The control will display
.
4. Press the #6 key (YES). The drain valve will open and the oil will drain from the tank into the filter pan and the control will display
5. With the oil drained into the filter pan you may clean the fry tank. Using a water dampened clean cloth, wipe the insides of the fry pot to remove crumbs and debris. Scrub crumb ring in frypot with abrasive pad if needed. REMOVE ALL MOISTURE from the tank before proceeding to the next step.
6. When cleaning has been completed, press the #6 key to close the drain valve. The control will display
.
7. To return the oil to the fry tank, press the L key. The control will display .
8. Press the #6 key (YES) to turn the filter motor on and begin returning the oil to the fry tank.
The control will display .
9. When the tank is full press the #6 key (YES) to turn the filter pump OFF. The control will display
.
10. You can now exit the Fryer Control Menu by pressing the ON/OFF or Filter key.
You may want to reheat the oil in the fry tank and perform a full auto filter. Additional filtering procedures, settings and control functions can be found in the Control manual that was shipped with your fryer.
9.1.2. REPLACING THE FILTER MEDIA (if equipped)
Refer to the following procedure to replace the filter media if the appliance is equipped with a filter drawer. The diagram below shows a Solo Filter style pan and associated parts. Additional filter types are available.
1. Detach the pickup tube from the filter pickup assembly by unscrewing it (counterclockwise), at the knurled fitting, from the threaded fitting on the filter screen.
2. Slide off the filter paper clip and remove used filter paper from filter screen. Clean and completely dry pan and pan components. Replace with new filter paper, ensuring that the hole in the paper is on the top, so that threaded fitting in filter screen protrudes through it.
3. Fold filter paper to the underside of the filter screen and replace filter paper clip.
4. Re-attach filter pickup tube to the filter screen by screwing it (clockwise) into the threaded fitting in filter screen.
5. Reinstall the filter pickup assembly into the filter system by placing the newly covered screen portion of the assembly into the filter pan and connecting the quick disconnect on the filter pickup assembly into white donut fitting on the left-hand side of the appliance. Ensure that it snaps tightly and securely into donut fitting.
1. Filter Pan (Solo Filter style shown)
2. Filter Pickup Assembly
Strainer
Paper
5. Filter Screen
WARNING
The power supply must be disconnected before cleaning and servicing this appliance!
WARNING
The contents of the crumb catch and/or filter pan of any filter system must be emptied into a fireproof container at the end of the frying operation each day. Some food particles can spontaneously combust into flames if left soaking in certain oil/shortening materials.
22 L20-407 rev.4 (011/16)
INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL
INSPECTION
Check that the high temperature limit and temperature probe are in the correct position and secured in place. (Refer to illustration on page 11 of this manual).
Check that wires and cords are not frayed or loose in and out of the cabinet.
Check around the appliance for loose parts or accessories that need to be secured or other foreign items (ex: Aerosol cans) that should be removed from the area.
Check for oil/shortening leaks around the inside and outside of the cabinet and around the appliance.
WARNING
Serious injury could result from direct contact with hot surfaces and/or oil. Always wear apron, heat resistant gloves for skin protection and goggles for eye protection
WARNING
Read the operation section of this manual prior to filling or operating the appliance.
WARNING
DO NOT leave the appliance unattended during cleaning.
9.1.4. CLEANING THE COOK TANK
1. Turn the appliance off. Drain all the oil/shortening from the tank and allow the tank to cool.
2. Remove baskets, tank rack and basket hanger for cleaning.
3. Using the cleaning brush, remove all the loose debris and scrub all tank surfaces.
4. For tougher carbonized oil/shortening and carbon buildup scrub tank using a Scotchbrite or other abrasive pad. DO NOT use steel wool.
5. Wipe residue with a clean damp cloth and carefully dry any remaining oil/shortening droplets from the tank before returning oil/shortening into the tank.
6. Clean and dry baskets, tank rack and basket hanger before reinstalling.
9.1.5. CLEANING THE CABINET
1. Wipe any spilled oil/shortening, dust and lint from the cabinet exterior with a clean damp cloth and a mild food grade detergent. Be careful not to get any water or detergent in the oil/shortening. Use a nonabrasive pad for tougher stains if needed.
2. Remove detergent from all surfaces.
3. Cleaning the interior cabinet requires a clean cloth to remove any oil/shortening, dust, lint or filter powder (i.e.: Magnesol) from the interior of the cabinet.
1. Unscrew filter strainer cap from pickup tube and remove any crumbs from the slots. Use a clean cloth to remove any remaining crumbs and reattach.
2. Scrape all loose debris and crumbs from filter pickup assembly and filter pan with the filter scoop shovel.
3. Remove filter pickup and place in pot sink, power soak sink or dishwasher for cleaning. Be sure to rinse thoroughly and dry all surfaces before re-assembly.
4. Wipe the filter pan with clean damp cloth and a food grade detergent. If necessary, place pan in pot sink to rinse all the detergent from the surfaces.
5. CAUTION - Ensure that all parts and surfaces are completely dry before re-assembling and using.
L20-407 rev.4 (011/16) 23
INSTALLATION & OPERATIONAL SSHLV MANUAL
Performing the preventative maintenance steps above on a daily basis will keep your equipment clean and safe. On a weekly basis these additional steps should be performed. Wear personal protective gear when performing preventative maintenance!
1. Turn the fryer off. Allow the oil/shortening to cool to room temperature before pulling the fryer away from the hood. Hint: This maintenance may be ideal to perform on the day the oil/shortening is being changed so no oil/shortening is present in the tank or filter.
2. Disconnect the power cord(s), gas hose, retention lanyard and bulk oil line (if present).
3. Wearing your protective gear, pull the fryer away from the hood.
4. Check that vent hood drip cup is empty and not dripping oil/shortening into the flue.
5. Check that the hood baffles are clean and not dripping oil/shortening into the flue.
6. Clean the fryer sides, back and the flue area, it may be necessary to use a non-abrasive pad to scour and a putty knife to scrape the oil/shortening buildup. With a clean damp cloth and food grade detergent wipe the area clean.
7. Wipe up any excessive oil/shortening on the power cord(s) and gas hose with a dry cloth.
8. Check flue pipe for any foreign debris/object and remove if found.
9. Reattach power cord(s), gas hose, retention lanyard and bulk oil connection (if present) push fryer back under the hood.
PREVENTATIVE MAINTENANCE
Food debris and oil/shortening can build up inside the tank. Performing the monthly preventative maintenance steps below will keep your equipment safe and at peak performance. If you are producing high quantities of fried food and/or frying heavily battered food, it may be necessary to clean these components more than once a month.
9.3.1. BOIL OUT PROCEDURE
Wear protective gloves and clothing when cleaning and draining the appliance. Oil/shortening, water or steam may spatter and will cause injury to personnel.
1. Read the “operation” section of this manual prior to filling or operating the appliance.
2. Turn the appliance off. Drain all the oil/shortening from the tank into a container and allow it to cool. The container must be large enough to hold the entire contents of the tank and must also be able to withstand 400 F (205 C) temperatures.
3. To drain the tank of manual models, drain the tank by pulling the blue handle out.
4. To drain the tank of automatic models, push and hold the key to enter the Fryer Control
Menu. Press the #1 key. The message will display on the control. .
5. Press the #6 key (YES). The drain will open and the oil will drain into the container. The control will display .
6. Remove baskets, tank rack and basket hanger for cleaning.
7. Remove and discard any large debris inside the tank.
8. Close the drain valve. On manual models, the drain can be closed by pushing the blue handle in all the way. On automatic models, press the #6 key (YES). The drain will close, the control will display .
9. Fill the tank with water and place the appliance into boil mode:
Turn the appliance ON. As the water heats up, the controller will recognize that there is water in the tank and automatically enter boil mode. To enter boil mode manually, press the Temp
Key then keys 2, 1, 2 for degrees F or 1, 0, 0. for degrees C. The display will read ‘BOIL’.
10. Once the water reaches a simmer, follow the directions of the boil out product that you are using.
24 L20-407 rev.4 (011/16)
INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL
11. Scrub the inside of the tank using a cleaning brush safe for hot water. Care must be taken to remove all the foreign material on the tank, heating tubes, sidewalls and other components in the tank. Be careful not to loosen or damage the high limit or temperature probe during when scrubbing.
NOTICE
DO NOT run water through the filter return system. This will damage the pump and void your warranty.
12. Drain the water from the tank into a container that is large enough to hold the contents of the tank and is suitable for use with 212°F(100°C) water.
Manual models: pull the blue handle out. The drain will open.
Automatic models: push and hold the key to enter the Fryer Control Menu. Press the #1 key. The message will display on the control. Press the #6 key (YES). The drain will open; the control will display .
13. Once the tank has cooled, rinse it thoroughly with clean, potable water.
14. Remove all remaining water and residue with a clean dry cloth.
15. Clean and dry baskets, tube rack and basket hanger before reinstalling
16. Close the drain valve and fill the cooker tank with oil/shortening.
Manual models, push the blue handle in. The drain will close.
Automatic models, press the #6 key (YES). The drain will close; the control will display
To exit the Fryer Control Menu, press the ON/OFF key or the Filter key .
17. You can now fill the tank with oil/shortening.
CHECK
1. Use a high-grade pyrometer or digital thermometer suitable for temperature up to 380 F
(182°C). Place the thermometer in the oil above the tip of the fryer’s temperature probe with in 1” (2.54 cm) 25.4 mm). Be sure not to touch the heat tube since this will measure incorrect temperatures. Allow several minutes for the thermometer to equilibrate with the oil temperature.
2. Press the Thermometer key on the computer, and compare the actual temperature to the
thermometer reading.
3. The two readings should be within a range of ± 5°F (±2.7°C) of each other. If the two
readings are not within the desired range, contact your local service representative or
Technical Support at the number on the back of this manual.
.
L20-407 rev.4 (011/16) 25
INSTALLATION & OPERATIONAL SSHLV MANUAL
This section should ONLY be performed by a qualified service technician as part of a regular kitchen maintenance program. This inspection should take place a minimum of once a year by an Authorized
Service Technician recommended by Pitco. It may be necessary perform this inspection more than once a year.
WARNING
The power supply must be disconnected before cleaning and servicing this appliance!
Evaluation
Check power cord and plug.
Check all exposed wiring connections, switches, and indicator lights.
Check legs, casters, wheels, plate welds and ensure all nuts and bolts are secured.
Check conditions of flexible gas line and verify fryer retention / lanyard system is in place.
Inspection
Check frypot for shortening leaks and excessive oil build up
Check for oil migration (Clean as required)
Check hood drain cup, ensure it is empty and not dripping into the flue.
Check hood baffle for clean surface, oil/water condensate can drip on and into the flue.
Check flue for foreign debris and hood down draft currents.
Check drain/filtration system (if equipped) for leaks
Check for missing fryer parts, i.e.: cover strips
Check for missing fasteners
9.4.3. Temperature Control System
Check electrical connections and harnesses
Check temperature probes and limits for carbon build up and plating. Clean as required
Check proper mounting of probes and sensors and all fasteners are secure.
Check thermistor probe resistances for stability.
Check DVI Drain Valve Interlock drops out controller.
Check Controller/thermostat features to ensure they are functioning.
Check Temperature Calibration
9.4.4. Filter System (If Equipped)
Check electrical connections and harnesses.
Check IEC power cords are fully engaged and secure.
Check for any air or shortening leaks and for excessive oil build-up.
Check O-Ring on filter pickup tube and replace as needed.
Check filter strainer on pickup tube.
Check operation of drain valve and DVI drain valve interlock.
Check operation of return oil valve and its pump switch.
Check operations of flush hose quick disconnect (if equipped), clean and lubricate as needed.
Check all hardware in filter pan.
Check filter operation by filtering the fryers.
Check pump motor amp draw compare to nameplate amperage.
Check pump and motor, clean any excess oil from pump assembly.
Check all filter hoses for leaks and integrity.
26 L20-407 rev.4 (011/16)
INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL
9.4.5. GAS COMBUSTION SYSTEM
Check for gas leaks.
Check and clean vent tube on gas valve pressure regulator.
Check burners, clean debris and grease from pilot and pilot orifice tips.
Check self cleaning burner system (if equipped) that it activates when the appliance is turned on and NOT during normal cooking & idle periods.
Check and adjust burner manifold gas pressure to nameplate reading.
Check incoming gas pressure to the appliance under static and dynamic conditions.
Check ignition system and adjust pilot flame as required.
Check flame sensor reading.
Check gap spacing and clean igniter.
Recheck for gas leaks after inspection.
Proper ventilation hood operation is very important for the correct operation of this appliance and the safety of personnel. The ventilation hood should be inspected at the time of installation of this appliance to ensure that it will operate properly in conjunction with the appliance. A regular schedule of examination in accordance with ANSI/NFPA 96 latest edition and/or local codes must be followed.
L20-407 rev.4 (011/16) 27
INSTALLATION & OPERATIONAL SSHLV MANUAL
10. TROUBLESHOOTING
FAILURE
If electric power is removed for any reason, the appliance will shut down.
Wait five minutes after the power is restored before attempting to restart the appliance. This will allow time for any gas that may have accumulated in the burner or tubes to dissipate.
To restart the appliance, follow the appliance start up procedure outlined previously in this manual.
CAUTION
DO NOT attempt to operate this appliance during a power outage.
10.2. HIGH TEMPERATURE LIMIT SWITCH
This appliance is equipped with a high temperature limit switch. The high temperature limit switch will stop the appliance from functioning if the oil temperature in the cook tank reaches an unsafe temperature. In the event that the high temperature limit has tripped, please refer to the following procedure to reset the switch.
NOTE : The high limit reset button is located behind the gas valve and is not readily visible to the user. a. Turn the appliance off. b. Allow the appliance ample time to cool to room temperature. c. Add oil/shortening to the cook tank as needed. d. Press the high temperature reset button. e. The high limit switch is now reset and the appliance is ready for startup.
10.3. DRAIN VALVE INTERLOCK
WARNING
DO NOT add oil/shortening to the tank until it has been given ample time to cool down.
Failure to do so may result in damage to the appliance and/or injury to the operator.
Your appliance is equipped with a drain valve interlock circuit; the appliance will stop heating if the tank drain valve is opened. The appliance will turn off, and scroll a message “DRN TRN OFF”. Refer to the following procedure to resume operation after the drain valve interlock is tripped.
1. Turn the computer OFF (if not already OFF).
2. Close the tank drain valve:
Manual models: push the blue handle in. The drain will close.
Automatic models: press and hold the key to enter the Fryer Control Menu. Press the #1 key: the control will display . Press the #6 key to open the drain valve. The control will display
. Press the #6 key to close the drain valve. The control will display . If the drain valve does not close it is possible that there is an obstruction in the drain line. Allow the appliance to cool and, wearing PPE, clear the obstruction from the drain. Once the obstruction is cleared, repeat the previous steps to ensure that the drain valve is closed. If there is no obstruction and the drain valve still will not close there may be a hardware malfunction. Call Pitco Technical Support at the number provided in this manual. Otherwise, to exit the Fryer Control Menu, press the ON/OFF key or the Filter key .
3. Fill the tank with oi/shortening.
4. Turn the computer ON and resume normal operation.
28 L20-407 rev.4 (011/16)
INSTALLATION & OPERATIONAL SSHLV MANUAL
10.4. SELF CLEANING BURNER SYSTEM
If your appliance is equipped with the self cleaning burner system, the appliance should behave as outlined in the table below. A cleaning cycle will execute every time the appliance is turned “ON” from an “OFF” state. The thermal cut out switch is designed to disable the appliance if the Self Cleaning
Burner System malfunctions and remains activated for an extended period or if there is a downdraft into the flue or a blocked flue situation.
Turn appliance “ON”
Pre-Purge Pulse
Interwaiting period 1
Cleaning Pulse
N/A
2 seconds
5 seconds
6 seconds
Control Illuminates, pilot sparks and ignites. Pre-Purge pulse is initiated.
Appliance operates briefly and stops. Pilot remains lit.
Appliance does not operate. Pilot remains lit.
Main valve operates, lighting main burners. SCBS valve operates, feeding gas to the SCBS Arm. The SCBS arm ignites, initiating a brief burn at the main burner orifice of
Interwaiting period 2 8 seconds each burner.
The Main and SCBS valves de-energize for this period.
The pilot remains lit.
Normal operation resumes
N/A
The appliance operates normally and begins to heat up.
The SCBS Valve remains de-energized until power to the appliance is recycled. There is no flame on the
SCBS Arm. There is no burn at the main burner orifices.
* If flame sense on the pilot is lost during the SCB cycle, the SCB cycle will start over.
10.5. RESETTING THE SELF CLEANING BURNER ROLL OUT SWITCH
1. Turn the appliance off and allow ample time for the appliance to cool to room temperature.
2. Press the SCBS roll out switch reset button. The reset button is located behind the door at the top of the main burners.
3. The SCBS roll out switch is now reset and ready for startup.
4. If the SCBS roll out switch continues to trip, have the appliance inspected by an Authorized
Professional.
L20-407 rev.4 (011/16) 29
INSTALLATION & OPERATIONAL SSHLV MANUAL
10.6.1. Fryer Troubleshooting Chart
Computer Controller display doesn't light.
Controller is on and appliance will not heat up.
Appliance will not maintain temperature properly.
No power to appliance.
Circuit Breaker/GFI tripped.
Power Cord loose or not connected.
Check main building power supply.
Reset circuit breaker/GFI.
Connect power cord. Verify that power cord is plugged at the rear of the appliance.
Fuse blown.
Transformer Defective.
Defective Controller.
Computer is in Melt Cycle
Contact Authorized Service Company.
Contact Authorized Service Company.
Contact Authorized Service Company.
Allow time for unit to heat up.
Gas not turned on/ connected. Turn the gas on/connect gas to the appliance.
SCBS Roll out switch has tripped.
High temperature limit has tripped.
Faulty temperature probe.
Allow the appliance to cool and reset the SCBS
Roll out switch.
Allow the appliance to cool and reset the High
Temperature Limit switch.
Contact Authorized Service Company.
Incorrect gas pressure.
Adjust the gas pressure or contact Authorized
Service Company.
Faulty High temperature limit. Contact Authorized Service Company.
Computer display shows off, cannot be turned on.
Faulty computer Contact Authorized Service Company.
10.6.2. Filter Troubleshooting Chart (if equipped)
Problem
Filter pump does not activate
Oil/Shortening is returning to the tank slowly or not at all.
Possible Causes
The filter pump circuit breaker has tripped.
The thermal overload on the pump motor has tripped.
Dirty filter paper/too much debris on filter paper.
Strainer cap is dirty/clogged.
Filter pan is not properly installed/filter pickup is not completely pushed in.
Corrective Actions
Reset the circuit breaker.
Allow the motor to cool and reset the thermal overload on the motor.
Change filter paper/clean debris from filter paper*.
Remove, clean and reinstall strainer cap*.
Check filter pan for proper installation/push filter pickup in completely*.
Excessive air bubbles occur while oil is being returned to the fry tank.
Drain valve is closed but the computer controller still displays
'DRAINING'.
Pick up tube screen in the filter pan is not tight.
Pick up tube screen cap is loose or missing.
Filter pan is not properly installed/filter pickup is not completely pushed in.
The blue drain valve handle is not pushed in all the way.
Improperly adjusted or defective drain switch
Tighten the tube screen on the filter pickup assembly*.
Tighten or install the Pick up tube screen cap*.
Check filter pan for proper installation/push filter pickup in completely*.
Ensure that the blue drain valve handle is pushed in all the way.
Contact Authorized Service Company
* Wait for the oil and/or appliance to cool to room temperature before attempting these corrective
actions.
30 L20-407 rev.4 (011/16)
INSTALLATION & OPERATIONAL SSHLV MANUAL
10.6.3. COMPUTER CONTROLLER DISPLAYS
Below is a list of common computer controller displays and guidance. For additional computer controller displays and information concerning them, refer to the controller manual that was shipped with your appliance.
Display Problem
Controller is OFF
Oil/shortening temperature is low.
Action
Press [I/O] key to turn controller ON
Wait for appliance to heat up.
Fryer is slowly heating.
Oil/shortening temperature is low. Wait for appliance to heat up.
Fryer is slowly heating.
Oil/shortening temperature is low.
Fryer is heating.
Wait for appliance to heat up.
Oil/Shortening is at temperature and ready to cook.
Perform cooking activites as needed.
Drain valve is open while controller is on.
Ignition system has locked out.
Incorrect probe reading.
Turn off appliance. Close drain valve before turning appliance back on.
Refer to Fryer Troubleshooting section.
Contact a qualified service technician.
Oil/shortening has reached an unsafe temperature.
Incorrect probe reading.
Temperature probe is shorted.
This message indicates that oil in the vat is in need of polishing
This message indicates that the computer has lost communication with the autofilter control board and oil management operations are suspended. Normal cooking activities are unaffected.
Turn off appliance. Allow ample time for applicance to cool before turning on.
Contact a qualified service technician.
Contact a qualified service technician.
Operators may (depending on settings) polish now, or defer the polish filter opertion for a later time.
Contact a qualified service technician.
Perform a filter operation as soon as
This message shows when the business levels permit. number of cooks since the last filter operation is greater than the
Cook Counts Allowed Value.
Indicates that JIB is low or empty.
If the JIB EMPTY message is displayed, the operator should replace the empty JIB with a new, full JIB. Refer to the Control
Manual shipped with your fryer to clear this message.
L20-407 rev.4 (011/16) 31
Annual service to this appliance by an authorized person is recommended. Do not modify this appliance: servicing must only be carried out by an authorized person. For service and parts, minor adjustments, fault finding, or if this appliance cannot be adjusted to operate correctly, contact:
In the event of problems with or questions about your order, please contact the Pitco Frialator factory at:
In the event of problems with or questions about your equipment, please contact the
Pitco Frialator Authorized Service and Parts
(603) 225-6684 World Wide
Website Address: www.pitco.com representative (ASAP) covering your area, or contact Pitco at the numbers listed to the left.
MAILING ADDRESS – P.O. BOX 501, CONCORD, NH 03302-0501
L20-407 rev. 4 (11/16)
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project