SERVICE MANUAL MODEL 350-300R

Add to my manuals
13 Pages

advertisement

SERVICE MANUAL MODEL 350-300R | Manualzz

350-300R-ISSUE4.0 121010

SERVICE MANUAL

FOR

MODEL 350-300R

VISITATION POWER SYSTEM

EQUIPPED WITH FILTERED RECORDING CONNECTIONS

Communication Equipment

& Engineering Company

Serving the Telephone Industry Since 1930

519 West South Park Street

Okeechobee, Florida 34972

Voice: 863-357-0798

Fax: 863-357-0006

IMPORTANT INFORMATION

FOR

CUSTOMER

Please fill in before you continue.

The following information is necessary when calling CEECO for assistance.

MODEL NUMBER

SERIAL NUMBER

MODEL 350-300R VISITATION

POWEWR SYSTEM.

DATE MANUFACTURED

LOCATION INSTALLED

For us to better serve you, please have this information available when calling for technical support.

CEECO

Communication Equipment & Engineering Company

519 West South Park Street

Okeechobee, Florida 34972

(863) 357-0798 Voice

(863) 357-0006 Fax

ISSUE 4.0

CEECO

Communication Equipment & Engineering Company

PROPRIETARY

2

ISSUE 4.0

TABLE OF CONTENTS

SECTION PAGE

1.0 INTRODUCTION................................................................................................... 4

2.0 GENERAL DESCRIPTION.................................................................................. 4

3.0 OPERATION .......................................................................................................... 4

4.0 RECOMMENDED TOOLS AND TEST EQUIPMENT .................................... 5

5.0 INSTALLATION NOTES AND ASSEMBLY INSTRUCTIONS ..................... 6

6.0 TESTING................................................................................................................. 7

7.0 SPECIFICATIONS................................................................................................. 8

8.0 PARTS LIST ........................................................................................................... 9

9.0 REPAIR AND RETURN INFORMATION....................................................... 10

10.0 WARRANTY POLICY ........................................................................................ 11

CEECO

Communication Equipment & Engineering Company

PROPRIETARY

3

ISSUE 4.0

1.0 INTRODUCTION

The practices in this manual provide installation, technical and maintenance information for Model 350-300R Visitation Power System.

The information in this manual is subject to change without notification.

For information not included in this manual, please call or write:

CEECO

Customer Service

519 West South Park Street

Okeechobee, Florida 34972

(863) 357-0798

(863) 357-0006 FAX

2.0 GENERAL DESCRIPTION

The CEECO Model 350-300R is a Visitation Power System designed for special purpose applications that require a rugged and convenient means for wiring multiple visitation units to the power supply, individual loops, and recording apparatus. The system includes an AC to DC power supply, insulated screw terminals for up to 32 visitation units (16 pair), insulated screw terminals for attaching recording apparatus to each pair, audio balancing and filtering components, and instruction plate, all in a rack or wall mountable, pre-wired configuration with mounting hardware.

Note: Wire for connecting the 350-300R to the telephone/visitation units and/or the recording apparatus is not included.

3.0 OPERATION

The CEECO Model 350-300R Visitation Power System is designed to provide power, talk path loops, and recording points for up to 16 pairs (32 units) of the

CEECO 350 Series Visitation Telephone Units. Once installed, the system provides regulated and balanced power such that each telephone pair may conduct a conversation of high sound quality immediately upon lifting each pair to the ear.

The record connection points provide capacitance filtering for clear quality sound recordings from each pair. The record parameters are dependent upon the chosen apparatus.

CEECO

Communication Equipment & Engineering Company

PROPRIETARY

4

ISSUE 4.0

4.0 RECOMMENDED TOOLS AND TEST EQUIPMENT

Meter

¼” Nut Driver

Flat Blade Screw Driver

Small Flat Blade Screw Driver

Wire Strippers/Cutters 22-26 gauge

Small Needle Nose Pliers

Security Tool, CEECO Part Number 301-064.

***** WARNING *****

A. Never install telephone wiring during a lightning

storm.

B. Never install telephone wiring in wet locations unless the wiring is specifically designed for wet locations.

C. Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface or other power supply.

D. Use caution when installing or modifying telephone lines or

E. Do not attach wiring to or remove wiring from the CEECO

Model 350-300R without first unplugging the unit from the

CEECO

Communication Equipment & Engineering Company

PROPRIETARY

5

ISSUE 4.0

5.0 INSTALLATION NOTES AND ASSEMBLY INSTRUCTIONS

5.1

The power supply is intended to run on a 100-240 VAC 2A 50/60Hz line and comes with a 3-prong grounding plug. The outlet must be grounded, or a separate ground wire should be run from the individual phone units to a suitable ground. Do not plug the power supply into the outlet until the

CEECO Model 350-300R is mounted and all wiring is completed. The selected location must be safe and secure and, *Grounding and

installation must be in accordance with all applicable local and

national electrical and building codes.

5.2

Determine the desired mounting location for the 350-300R and mount securely to the wall or rack utilizing the include hardware. Page 12 of this manual may be referenced for dimensions for mounting.

5.3

Attach the wire pairs from each visitation pair to the appropriate screw terminal positions on the 350-300R, as per the diagram on page 13 of this manual. It is best to match the wire color codes between the visitation units and the visitation system. For those visitation telephone units that have red and green wires, the green corresponds to gray and the red corresponds to white on the 350-300R.

5.4

Attach the wire pairs from the recording equipment to the appropriate screw terminal positions on the 350-300R, as per the diagram on page 13 of this manual.

5.5

Run the modular cords through the knock out holes in the mounting boxes.

Mount the telephone units, utilizing the security screws provided, to the mounting boxes. The security tool, which is sold separately, must be used for the security screws.

5.6

Note: For high sound quality conversations and recordings, be certain that each set of connected wires is cleanly stripped and tightly attached to the screw terminal positions.

5.7

After ensuring that each connection has been properly made, and all wires have been neatly and safely routed, plug the power supply of the CEECO

Model 350-300R into the intended outlet. All audio paths should be available as wired.

CEECO

Communication Equipment & Engineering Company

PROPRIETARY

6

ISSUE 4.0

6.0 TESTING

6.1 Once installation has been completed, allow the phones to rest on-hook a few minutes, with the power supply on.

6.2

Lift the handsets of the units that are intended to talk to one another.

Determine that normal conversation is allowed. If so, return the handsets to the cradles. The phone units are ready for use.

6.3

If normal conversation does not take place, please review the installation steps. Make a visual check to ensure that all wires and connectors are as they should be. Remember that the phone units, which are connected to the same screw terminal points, will allow talk paths to one another. A phone connected to one screw terminal point cannot talk to a phone connected to another jack/interface.

6.4

Conduct a test recording from each of the telephone pairs to ensure that the recording operation is clear and as intended. If the recording is not clear or as intended, re-examine the wiring to the record points of the 350-

300R. Remember that each of the recording wire pairs can only record voice from the telephone units that are wired to that same screw terminal set on the 350-300R.

6.5 Once it has been determined that the installation and connections are correct, the system is ready for use. If trouble is still experienced, please refer to section 9.2 of this manual.

CEECO

Communication Equipment & Engineering Company

PROPRIETARY

7

ISSUE 4.0

7.0 SPECIFICATIONS

INPUT POWER: 100-240VAC, 2A, 50/60Hz

LOOP CURRENT:

IMPEDANCE:

LOOP RESISTANCE:

ENVIRONMENTAL:

WIRE GAUGE:

DIMENSIONS:

MOUNTING:

23 ma min. to 80 ma max.

600 Ohms

100 Ohms 2 Watt

Temperature 0° C to 50° C

24 Gauge (White=Low; Gray=High)

19" Wide x 10.5" High x 3" Deep

RACK 19” Wide x 7.5” High

WALL 16” Wide x 9 3/16” High

CEECO

Communication Equipment & Engineering Company

PROPRIETARY

8

ISSUE 4.0

8.0 PARTS LIST

QUANTITY PART NUMBER DESCRIPTION

1 350-300R Visitation Power System

Supply

8 301-10086 Insulated

Frame

Terminal

32

16

4 Hardware

4 Hardware

#10-32 x 1" Screw, Nut, Washer

1.5” Deck/Dry Wall Screw

6-32 Screw

6-32 Screw

19

2 Hardware

CEECO

Communication Equipment & Engineering Company

PROPRIETARY

9

ISSUE 4.0

9.0 REPAIR AND RETURN INFORMATION

9.1 WARRANTY REPAIR

Any device returned requiring warranty service; repair or credit must be accompanied with a "Return Material Authorization" (RMA) Form. It must include: return-shipping instructions, original purchase order number and special marking instruction. A description of the trouble observed must be attached to the defective unit. This information must be inside the shipping container.

9.2 DIRECT ALL INQUIRES TO:

CEECO

Repair Department

519 West South Park Street

Okeechobee, Florida 34972

9.3 NON-WARRANTY REPAIR

CEECO will repair equipment out of warranty for a set charge plus parts.

The customer must pay the shipping costs both directions.

9.4 RETURN FOR CREDIT

Material may be returned for credit only with prior approval. Material authorized for return is subject to a 20% restocking charge based on the manufacturer's list price. Return RMA must be requested no later than 30 days after original shipment.

CEECO

Communication Equipment & Engineering Company

PROPRIETARY

10

ISSUE 4.0

10.0 WARRANTY POLICY

10.1 GENERAL

CEECO products are guaranteed to be free of defects in material and workmanship for a period of 365 days from the date of original purchase.

CEECO's obligation under this warranty is limited to repair or replacement of any part found to be defective by CEECO. Under no circumstances shall CEECO be liable for loss, damage, cost of repair or consequential damages of any kind, which have been caused by neglect, abuse, acts of God or improper operation of equipment. This warranty is limited to the value of material only.

10.2 PRINTED CIRCUIT BOARDS

Printed circuit boards should not be field repaired. If a unit is found to be faulty, replace it with another unit and return the faulty unit to CEECO for repair. Modifications by any one other than CEECO will void the warranty.

CEECO

Communication Equipment & Engineering Company

PROPRIETARY

11

11.0 DIMENSION & WIRING DIAGRAM

ISSUE 4.0

CEECO

Communication Equipment & Engineering Company

PROPRIETARY

12

ISSUE 4.0

12.0 WIRING DETAILS DIAGRAM

REC

OUT

PAIR 13

REC

OUT

PAIR 14

REC

OUT

PAIR 15

REC

OUT

PAIR 16

REC

OUT

PAIR 9

REC

OUT

PAIR 10

REC

OUT

PAIR 11

REC

OUT

PAIR 12

TO

POWER

SUPPLY

REC

OUT

PAIR 5

REC

OUT

PAIR 6

REC

OUT

PAIR 7

REC

OUT

PAIR 8

REC

OUT

PAIR 1

REC

OUT

PAIR 2

REC

OUT

PAIR 3

CEECO

Communication Equipment & Engineering Company

PROPRIETARY

REC

OUT

PAIR 4

13