Telegaertner 100013206 installation cable SF/UTP Cat.5 AWG24/1 PUR, RAL 6018, 305m/1000 ft. Data Sheet
Add to My manuals2 Pages
advertisement
a
Installation Cable
SF/UTP AWG24/1 Cat.5 PUR
Application
IEC 11801-1:
EN 50173-1:
IEEE 802.3:
IEEE 802.3:
Applicable Standards
Design specification:
Fire behaviour
Euroclass:
Smoke production:
Acidity:
Flaming droplets:
Flame retardant:
Halogen free:
Smoke density:
Construction
Construction:
Conductor:
Insulation:
Twisting:
Cable lay up:
Buffer layer:
Drain wire:
Overall screen:
Outer jacket:
Cable marking blue:
Mechanical properties
Outer diameter:
Bending radius:
Tensile force:
Weight:
Class D
Class D
10Base-T; 100Base-T; 1000Base-T
Power over Ethernet PoE; PoE+
EN 50288-2-1, EN 50174-2, IEC 14763-2,
IEC 61156-2, EN 50575+A1
-
-
-
-
IEC 60332-1
IEC 60754-2
SF/UTP bare copper wire Ø 0.52 mm (AWG24/1)
Polyethylene, Ø 1.01 mm
2 cores to the pair
4 pairs
Mylar tape
Copper wire, tinned Ø 0.52 mm (AWG 24/1)
Aluminium-laminated plastic foil, conducting side outward and copper braid, tinned with min. 60% coverage
PUR, green RAL 6018
Cat.5 SF/UTP 4x2xAWG24/1 PUR NVP 67% IEC 603321 “ production batch no.
“ “sequential length in meters“
6.5 ± 0.2 mm during operation: during installation: max. 100 N
51 kg/km
≥ 26 mm
≥ 52 mm
Telegärtner Karl Gärtner GmbH • Lerchenstraße 35 • D-71144 Steinenbronn • Tel.: +49 (0)7157/125-100 • Fax: +49 (0)7157/125-5120 • E-Mail: [email protected] • www.telegaertner.com
a
Installation Cable
SF/UTP AWG24/1 Cat.5 PUR
Environment and Security
Temperature range:
Fire load: during operation: during installation:
502 MJ/km
-40 ºC to +85 ºC
-10 ºC to +60 ºC
Oil resistance:
UV resistance:
Oil-resistant acc. to UL 758 60 °C
UV-resistant acc. to IEC 60068-2-5 (2 cycles of procedure B)
Electrical properties (typical at 20°C)
Characteristic impedance Z (1-100 MHz): 100 ± 15 Ω
Nominal velocity of propagation NVP:
Propagation delay:
Delay skew:
Loop resistance:
Resistance unbalance:
Insulation resistance (500V):
Mutual capacitance (at 1000 Hz):
Capacitance unbalance (pair/ground):
Test voltage (DC, 60 sec.)
(core/core und core/screen):
Transfer impedance (mΩ/m):
Coupling attenuation:
Segregation classification: ca. 67%
≤ 498 ns/100m
≤ 30 ns/100m
18.1 Ω/100m max. 19 Ω/100m pair: ≤ 2% between the pairs: ≤ 4%
≥ 500 MΩx100m
5.1 nF/100m
≤ 160 pF/100m
1000 V
Grade 2
Type 2 c
Transmission properties (at 20°C)
Has been verified as being compliant with the standards.
Order No. old / new Standard designation Scope of delivery
Copper content kg/km
L02002C0070 /
100013206
J-2Y(ST)C11Y 4x2x0.52 PUR
305 m (1000 ft) disposable wooden drum
The editions of the afore mentioned standards by the time of 15.04.2021 are valid.
-