advertisement
Smartec STC-3900
Day/Night Speed Dome Camera
User Manual
www.smartec-security.eu
Warnings and Cautions
WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS PRODUCT TO RAIN
OR MOISTURE. DO NOT INSERT ANY METALLIC OBJECTS THROUGH THE VENTILATION GRILLS OR
OTHER OPENINGS ON THE EQUIPMENT.
CAUTION
EXPLANATION OF GRAPHICAL SYMBOLS
The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instruction in the literature accompanying the product.
FCC COMPLIANCE STATEMENT
FCC INFORMATION: THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO
COMPLY WITH THE LIMITS FOR A CLASS A DIGITAL DEVICE, PURSUANT TO
PART 15 OF THE FCC RULES. THESE LIMITS ARE DESIGNED TO PROVIDE
REASONABLE PROTECTION AGAINST HARMFUL INTERFERENCE WHEN
THE EQUIPMENT IS OPERATED IN A COMMERCIAL ENVIRONMENT. THIS
EQUIPMENT GENERATES, USES, AND CAN RADIATE RADIO FREQUENCY
ENERGY AND IF NOT INSTALLED AND USED IN ACCORDANCE WITH THE
INSTRUCTION MANUAL, MAY CAUSE HARMFUL INTERFERENCE TO RADIO
COMMUNICATIONS. OPERATION OF THIS EQUIPMENT IN A RESIDENTIAL
AREA IS LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH CASE THE
USER WILL BE REQUIRED TO CORRECT THE INTERFERENCE AT HIS OWN
EXPENSE.
CAUTION: CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY
THE PARTY RESPONSIBLE FOR COMPLIANCE COULD VOID THE USER'S
AUTHORITY TO OPERATE THE EQUIPMENT .
THIS CLASS A DIGITAL APPARATUS COMPLIES WITH CANADIAN ICES-003.
CET APPAREIL NUMÉRIQUE DE LA CLASSE A EST CONFORME À LA NORME
NMB-003 DU CANADA.
CE COMPLIANCE STATEMENT
WARNING
THIS IS A CLASS A PRODUCT. IN A DOMESTIC ENVIRONMENT THIS
PRODUCT MAY CAUSE RADIO INTERFERENCE IN WHICH CASE THE USER
MAY BE REQUIRED TO TAKE ADEQUATE MEASURES.
IMPORTANT SAFEGUARDS
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer's instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that product heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Unplug this apparatus during lightning storms or when unused for long periods of time.
13. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
14. CAUTION - THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALIFIED
SERVICE PERSONNEL ONLY. TO REDUCE THE RISK OF ELECTRIC SHOCK DO
NOT PERFORM ANY SERVICING OTHER THAN THAT CONTAINED IN THE
OPERATING INSTRUCTIONS UNLESS YOU ARE QUALIFIED TO DO SO.
15. Use Certified/Listed Class 2 power supply transformer only.
Table of Contents
Chapter 1 — Introduction ......................................................................................................... 1
1.1 Features.........................................................................................................................................1
Chapter 2 — Installation and Configuration ........................................................................... 3
2.1 Package Contents ..........................................................................................................................3
2.2 Basic Configuration of Fastrax II E Dome Camera System ..............................................................4
2.3 Setting Dome Camera Termination .................................................................................................5
2.4 Setting Dome Camera Address (ID) ................................................................................................7
2.5 Setting Dome Camera Protocol.......................................................................................................8
2.6 Connections ...................................................................................................................................9
Connecting to the RS-485/ 422........................................................................................................9
Connecting Video out connector......................................................................................................9
Connecting Alarms ..........................................................................................................................9
Connecting the Power .....................................................................................................................9
2.7 Getting Started................................................................................................................................9
Chapter 3 — Program and Operation .................................................................................... 11
3.1 Dome Camera Selection............................................................................................................... 11
3.2 Accessing On-Screen Menu Utility ................................................................................................ 11
3.3 How to control On-Screen Menu Utility..........................................................................................12
3.4 Auto Scan.....................................................................................................................................12
3.5 Preset...........................................................................................................................................14
3.6 Shortcut Preset Program ..............................................................................................................15
3.7 Tour .............................................................................................................................................15
3.8 Pattern .........................................................................................................................................17
3.9 Alarm............................................................................................................................................18
3.10 Area Title ....................................................................................................................................19
3.11 Privacy Zone...............................................................................................................................20
3.12 Camera..........................................................................................................................................27
Focus Control .....................................................................................................................................
WB (White Balance) Control................................................................................................................
AE Control ..........................................................................................................................................
Line Lock Control ................................................................................................................................
Night shot menu .................................................................................................................................
3.16 Dome Setup.......................................................................................................................................
Language Setup..................................................................................................................................
Home Function Setup .........................................................................................................................
OSD Display .......................................................................................................................................
View Direction.....................................................................................................................................
Dome OSD Display.............................................................................................................................
Area Display .......................................................................................................................................
View Angle Setup................................................................................................................................
Panning Range ...................................................................................................................................
Flip .....................................................................................................................................................
Tilt Over Angle ....................................................................................................................................
Initialize Data ......................................................................................................................................
Origin Offset........................................................................................................................................
Dome Reset .......................................................................................................................................
System Information .............................................................................................................................
Appendix A — Specifications ....................................................................................................
Appendix B — Troubleshooting ................................................................................................
Appendix C — Glossary.............................................................................................................
Appendix D — Short Cut Key ....................................................................................................
Chapter 1 — Introduction
1.1 Features
The Fastrax II E dome camera and the Fastrax II Keyboard Controller make up the building blocks for any surveillance/security system. Using multiple Keyboard Controllers and multiple dome cameras, no place is too large for monitoring. Extensible and flexible architecture facilitates remote control functions for a variety of external switching devices such as multiplexers and DVRs.
· Built-in 18x times optical power zoom camera with True Night Shot function.
· 240 Preset positions.
· 8 Tours consist of Preset, Pattern, Auto-Scan and other Tours can be programmed with over
300 functions and Preset location. While moving, each Preset scan can be watched in smooth
Vector Scan mode.
· 8 Auto Scans including vector scan and 1 Endless Auto-Scan.
· 4 Patterns (240second).
· 8 Privacy zones.
· 8 Alarm inputs / 4 Aux outs (NC & NO).
· Variable speed from 0.1
° /sec to 90 ° /sec.
Turbo speed is Max 360 ° /sec with Ctrl key pressed.
Pan / Tilt speed is inversely proportional to the zoom ratio.
Maximum speed is 380 ° /sec when preset command.
· Programmable user preferences (alarm, preset, title, etc.).
· Up to 999 selectable camera addresses.
· Built-in RS-485/422 receiver driver.
· Clear bubble with black liner (shelter) for concealing the camera.
· Optional Tinted Bubble, Indoor & Outdoor pendant housing with heater & blower, Indoor Flush mount, Parapet mount & Roof Top mount.
Alarm Input
UP TO 8
<Sensor>
Alarm
Output
UP TO 4
<Siren>
<Flashing Light>
UP TO 32 CAMERA
UP TO 255 MULTIPLEXER
J- box
Master Keyboard
UP TO 99 DVR
Figure 1 – Typical System Configuration push remove camera window push bubble ring ass'y screw remove window assemble bubble ring ass'y
Figure 2 – Assemble bubble ring ass’y
Note: It is recommended to remove camera window for improving picture quality when you use bubble ring ass’y.
Chapter 2 — Installation and Configuration
2.1 Package Contents
The package contains the following.
Fastrax II E (Dome Camera)
Bubble Ring
Instruction Manual (This Document)
Assembly Screws for Attaching Fastrax II E
Plastic Anchor
10Pin Connector
12Pin Connector
………………………1
………………………1
………………………1
………………………3
………………………3
………………………1
………………………2
CAUTION: Be sure to have caution labels (
E
version only) on both the body and the base of the camera. Different version will not support input and output.
The dome camera is for use in surface mounting applications and the mounting surface should be capable of supporting loads up to 10lb (4.5kg).
The dome camera’s base should be attached to a structural object, such as hard wood, wall stud or ceiling rafter that supports the weight of the dome camera .
CABLE ENTRY
SURFACE(CEILING)
Unlock Lock
BASE
Align extruded tap in the base to the Keyhole on the pcb in the body
BODY Lock
Figure 3 – Installation
2.2 Basic Configuration of Fastrax II E Dome Camera System
RS485(+)
RS485(-)
J-BOX
DOME1 +
DOME
RX+(TX+)
DOME1 - RX-(TX-)
STP AWG # 22
POWER
AC 24V
ALARM OUTPUT
1~2
ALARM INPUT
1~4
SENSOR
ALARM INPUT
UP TO 8
SIREN BNC
RS-485
(RX+)
(RX-)
RX+(TX+)
RX-(TX-)
AC+
AC-
FGND
(RX+)
(RX-)
RX+(TX+)
RX-(TX-)
GND
AC-
AC+
POWER
AC 24V
DOME1 +
DOME1 -
LIGHT
ALARM OUTPUT
UP TO 4 MONITOR
ALARM OUTPUT ALARM INPUT
3~4 5~8
RS-485
HALF DUPLEX MODE : RX+,RX-
RS-422
SIMPLEX MODE : (RX+),(RX-)
DUPLEX MODE : (TX+),(TX-),(RX+),(RX-)
BNC
Figure 4 – Basic installation diagram
The dome camera must be installed by qualified service personnel in accordance with all local and federal electrical and building codes. The system should be installed according to Figures 4 through 9.
Termination Switches
SW1
ON
KSD02H
9A
1 2
Address(ID) and Protocol selection Switches
S3
S2
S1
45
67
89
123
45
67
89
123
45
67
89
123
S6
S5
S4
56
4
789
23
56
4
789
23
56
4
789
23
Figure 5 – Layout of Switches
2.3 Setting Dome Camera Termination
The device which is connected at end of line, whether it be a dome camera or keyboard controller, must have the cable for communication terminated by setting the appropriate DIP switch. Without proper termination, there is potential for control signal errors. Total length of the cable for communication should not exceed 1.2km.
SW1
ON
KSD02H
9A
1 2
SW1
Terminated
Not terminated
1
ON
OFF
Figure 6 – Setting Dome Camera Termination
2
ON
OFF
Figure 7- Termination Diagram
2.4 Setting Dome Camera Address (ID)
To prevent damage, each dome camera must have a unique address (ID). When installing multiple dome cameras using a multiplexer, it is suggested that the dome camera address match the multiplexer port number.
If you want to set the address more than 999, you should contact the service provider.
Example: Port 1 = Dome 1, Port 2 = Dome 2 … Port 16 = Dome 16. If more than 16 dome cameras are installed using two or more multiplexers, ID of the dome camera should be ID of
MUX x No. of camera IN. (e.g. multiplexer ID= n, Camera IN= m then ID of Dome =16x(n-1)+m )
Refer to Figures 4-5 for setting the dome camera address (ID) and protocol selection.
S3
45
67
89
123
S2
45
67
89
123
D OME ID
1
2
.
999
S3
0
0
.
9
S2
0
0
.
9
S1
45
6 7
89
123
Figure 8 – Setting Dome Camera Address (ID)
S1
1
2
.
9
2.5 Setting Dome Camera Protocol
If a dome camera is to be installed with a Fastrax keyboard controller, select F2 protocol.
Consult service personnel if a dome camera is installed with device other than a keyboard controller.
NTSC PAL
S/W On Off
D1 S4-1 Enable Disable
D2 S4-2 PAL NTSC
D3 S4-3 ENDLESS
D4 S4-4 RS-422 RS-485
F UNCTION
Alarm
NTSC/PAL
Pan mode
RS-422/RS-485
S4 S4
S6
S5
Camera
Baud rate
Protocol
D5 D6 D7
S5-1 S5-2 S5-3
Off Off Off
Off Off On
Off On Off
Off On On
On Off Off
On Off On
On On Off
On On On
P ROTOCOL
F2,F2E,P,D,E & Ph Protocol
(Default)
Reserved
S 422
Reserved
V Protocol
Reserved
D Color
Reserved
RS-422/
RS-485
S4
NTSC/PAL
Alarm
D8 D9 D10
S5-4 S6-1 S6-2
Off Off Off
Off Off On
Off On Off
Off On On
On Off Off
On Off On
On On Off
On On On
B AUD R ATE
2400 bps
4800 bps
9600 bps (Default)
19200 bps
38400 bps
57600 bps
115200 bps
230400 bps
D11
S6-3
Off
Off
On
On
D12
S6-4
Off
On
Off
On
Figure 9 – Protocol Selection Switches
C AMERA
Default cameras (Default)
Reserved
Reserved
Reserved
2.6 Connections
• Connecting to the RS485/ 422
The dome camera can be controlled remotely by an external device or control system, such as a control keyboard, using RS485 half-duplex, RS422 duplex or simplex serial communications signals. Connect Marked Rx+, Rx- to Tx+ and Tx- of the RS485 control system.
If control system is RS422, connect Rx+(Tx+), Rx+(Tx-) and Rx+, Rx- of the dome camera to
Tx+, Tx- and Rx+, Rx- of the control device respectively.
• Connecting Video out connector
Connect the video out(BNC) connector to the monitor or video input.
• Connecting Alarms
AL1 to 8 (Alarm In)
You can use external devices to signal the dome camera to react on events. Mechanical or electrical switches can be wired to the AL (Alarm In) and GND (Ground) connectors.. See
Chapter 3 — Program and Operation for configuring alarm input.
GND (Ground)
NOTE: All the connectors marked GND are common.
Connect the ground side of the Alarm input and/or alarm output to the GND connector.
NC(NO)1 TO 4 (Normal Close or Normal Open : Alarm Out)
The dome camera can activate external devices such as buzzers or lights. Connect the device to the NC(NO) (Alarm Out) and COM (Common) connectors. See Chapter 3 — Program and
Operation for configuring alarm output.
• Connecting the Power
Connect the power of AC 24V 850mA to the dome camera.
Use certified / Listed Class 2 power supply transformer only.
2.7 Getting Started
Once installed apply power to the dome camera. The dome camera will start a configuration sequence. When configuration is done, the following information is displayed on the keyboard controller’s LCD
RAM TEST
CHECK NO. : OK!
CHECK AAAA : OK!
CHECK 5555 : OK!
FASTRAX II E Vx.xxx
CAMERA TYPE xxxx
WAIT DOME SETTING.
INIT TILT ORGIN SET OK
INIT PAN ORGIN SET OK
INIT CAMERA SET OK
PRESET No.
001 PRESET
PRESET TITLE or AREA TITLE
INFORMATION
DISPLAY
EMPTY DATA !
FUNCTION
UNDER RUNNING
T001 DOMEID:0001
ALARM:1 W→360.0,090.0
ALARM DISPLAY
OSD Position
CAMERA TITLE
CAMERA ID
PAN & TILT ANGLE
VIEW DIRECTION
Chapter 3 — Program and Operation
3.1 Dome Camera Selection
Before you program or operate a dome camera, you must select the dome camera by pressing the dome camera No.
+ CAM
Example : Pressing 1 , 0 and CAM key sequentially will select dome camera 10. The selected dome camera ID will be displayed on the LCD monitor of the keyboard controller.
3.2 Accessing the On-Screen Menu Utility
You can call up the On-screen menu utility on your monitor by pressing MENU key on the keyboard controller, the following On-screen menu utility will appear:
DOME MENU
AUTO SCAN
PRESET
TOUR
PATTERN
ALARM
AREA TITLE
PRIVACY ZONE
CAMERA
DOME SETUP
EXIT(ESC TO EXIT)
3.3 How to control the On-Screen Menu Utility
Action
MENU
Joystick left or right
Joystick up or down
Joystick down
Zoom handle twist
CTRL + Joystick
ESC
Function
Call the On-screen menu utility
Go into the sub-menu items.
Execute the command(exit)
Change value.
Navigate through the menu items.
Navigate through the menu items.
Finish editing title.
Change value.
Enter editing title mode.
Change value of angle
Escape (EXIT)
3.4 Auto Scan
(First Item of the Main menu / Shortcut: SCAN )
The Auto scan supports up to 8 programmed angles at user-programmable speeds. Follow these steps to program Auto Scan:
AUTO SCAN SETUP
SCAN 01 : AUTOSCAN01
SPEED(MODE) : FAST VECTOR
START ANGLE : 127.1, 027.7 X7
END ANGLE : 157.7, 080.7 X13
SCAN DIR. : CCW
SWAP : OFF
SAVE AND EXIT (ESC TO CANCEL)
HOLD DOWN CTRL KEY
WHILE SELECT POSITION.
SPEED(MODE) : NORMAL1~NOMAL9,SLOW VECTOR,FAST VECTOR
NORMAL1 (SLOWER) ↔ NORMAL9 ( FASTER)
SLOW VECTOR, FAST VECTOR : Move from start point to end point including tilt and zoom simultaneously and linearly. In case of 22x models, zoom is fixed at more wide angle and the zoom magnification information is not displayed.
1. Press the SCAN key to enter Auto Scan menu directly. Or press the MENU key to display the main menu on the monitor. Scroll to Auto Scan and push the Joystick to the right.
2. Select an Auto Scan number by pushing the Joystick left or right.
3. Twist the Joystick to enter the title by scrolling through the alphanumeric characters and pushing the handle to the right or left to move to the next space. Press ENTR key or push the
Joystick down to finish title mode.
4. Push the Joystick downward to select “Speed” and set the speed by twisting the Joystick clockwise or counterclockwise (STT-2404CZP) to select the auto scan speed.
5. When finish entering the title, select “START ANGLE” with the Joystick . Hold down the
CTRL/PGM key while selecting the start position and the zoom using the Joystick . Current position will be displayed. Release CTRL/PGM key to complete the selection of the start position.
6. Push the Joystick downward to select “END ANGLE.” Hold down the CTRL/PGM key while moving the Joystick to select the end position and the zoom. The end position angle should be larger than start position. Release the CTRL/PGM key to complete the selection of the end position.
7. Select Save and Exit by pushing the Joystick to the right. Press ESC to exit the program without saving.
NOTE: Using the Tour mode in conjunction with preset and Auto Scan, you can make the camera travel from one preset position to another preset position at a specific speed. (Pan only) a. Before entering the Auto Scan menu, select a preset position as a starting point for Auto Scan.
Example : 2 + PRST and do step 1 to 4. Instead of step 5, just press the Ctrl/PGM key at the start angle position, the current position will be displayed as a start position.
b. Save and exit from the menu.
c. In normal mode, call a preset to be the end point of scan. Press 3 + PRST then press Scan key to enter the Auto Scan menu. Move the cursor position to END ANGLE. Just press
CTRL/PGM key at the end angle position. Do steps 7.
Example : Preset 001>002>003>004>005>006, Auto Scan 01 starts at 002, ends at 003,
Auto Scan 02 starts at 005, ends at 006. If you set Tour 01: 001, 002, A01, 004, A02.
1 è 2 2~3 è 4 è 5~6 è 1 è 2 2~3 ……
Where è : Quick move, ~ : Programmed speed by Auto Scan.
Also you can execute Endless Auto Scan which is to turn one direction continuously by Pressing
9 + SCAN.
3.5 Preset
(Second Item of the Main menu / Shortcut: PRST )
If you need to view specific places routinely, you should program presets. A preset is a programmed video scene with automatic pan, tilt, zoom, focus and iris settings. Once programmed, entering the number and pressing a Preset button on your controller automatically calls up the preset. In addition, presets may be assigned to alarm actions or as the “home” position for the dome camera. As many as 240 presets, whose positions are saved in the dome’s firmware, may be programmed.
There are three pages of preset menu, each page can hold 80 presets. Pages can be scrolled by pushing the Joystick to the Left or Right on the first or last No. of Preset.
PRESET SETUP
NO. 001: xxxxxxxxxxxxxxxx
FOCUS : AUTO (MANUAL)
IRIS : AUTO (MANUAL)
DWELL : 03 SEC(3~99)
1234567890 1234567890
00â–ˆ***======01==========
02==========03==========
04==========05==========
06==========07==========
JOY-LEFT TO PREV. PAGE
SAVE AND EXIT(ESC TO CANCEL) x : 16 digits of title for preset label
= : blank preset position
* : position has the preset
â–ˆ : Current cursor position
Follow steps below to store the Preset positions:
1. Press MENU to display the main menu. Select the Preset option by using the Joystick to the right. (Press Prst to go directly to the Preset menu without going through the main menu.)
2. Select the blank preset position to be stored by pushing the Joystick up, down, right, or left.
3. The position, which is marked with * , already has the preset view assigned. To review the stored preset, press Prst key on the * The camera will show the stored preset view.
4. After selecting a blank position, press and hold CTRL/PGM , Use the Joystick to control the direction of the camera and lens.
5. After aiming the camera (view direction and lens control), release CTRL/PGM . Then twist the
Joystick handle or Press Tele or Wide Key to store the selected view. The position number will be displayed and the user will be prompted to enter a preset title.
6. Enter the title for the preset position using the Joystick . (Rotate handle clockwise and counterclockwise or press Tele or Wide Key to scroll through the alphanumeric characters, push the handle to right or left to select next or previous digit.)
7. When you are finished entering the title, push the Joystick downward. Set the focus by pushing the Joystick to the right or left. Set the IRIS value in the same manner as the focus.
8. Move to the DWELL setting by pushing the Joystick down. Twist the Joystick clockwise or counterclockwise to increase or decrease dwell time of the preset position.
9. To select the next page of presets, scroll the page by pushing the Joystick to the Left on the first and last columns of the menu.
10. Repeat steps 2 through 8 for each additional preset position.
11. To edit the title of a stored preset, use the Joystick to position the cursor on the desired preset position ( * ). Press the Prst key to recall the stored preset. Twist the zoom handle clockwise to enter the preset title field. Preset titles are useful with short cut preset programming. Refer to Shortcut programming below.
12. Select Save and Exit by pushing the Joystick to the right. Press ESC to exit the Preset menu without saving.
NOTE: Press the Home key at programmed position to delete a programmed preset view.
3.6 Shortcut of Preset Program
Select a view to be stored (direction of the camera, zoom and focus), then press No. ( 1 to 240 ), and then press PGM , PRST subsequently. The current view will be stored to the selected preset number if position is empty. If selected preset number is not empty, “ PRESET EXISTING ” message will be displayed on the monitor and be prompted to overwrite.
Example : 1 , 0 , 1 + PGM + PRST will store current view as preset No.
101 . In this case, focus and Iris mode will be programmed as Auto, dwell time will be set to 3 sec.
3.7 Tour
(THIRD ITEM OF THE MAIN MENU / SHORTCUT: TOUR )
There are 8 programmable Tours. Each Tour consists of up to 42 Preset positions, Patterns,
Scans or other Tours (second-level). Using second-level Tours, it can be expanded to over 300 functions in a single Tour. However second level Tours will be ignored when called by a Tours.
The following example illustrates this concept:
If Tour1 has Preset1 è Preset2 è Tour2 è Tour3 and
Tour2 has Preset3 è Preset4 è Preset5 è Tour4and
Tour3 has Preset6 è Pattern 1and
Tour4 has Preset7.
Tour1 executes as follows:
Preset1 è Preset2 è Preset3 è Preset4 è Preset5 è Preset6 è Pattern1 è
Preset1 è ... (Repeat)
Tour2 executes as follows:
Preset3 è Preset4 è Preset5 è Preset7 è Preset3 … Repeat
(Tour4 is still valid if called directly from Tour2.)
TOUR 01:xxxxxxxxxxxxxxxx
SCAN TYPE:NORMAL
=== === 003 === === === ===
A08 === === === === === ===
=== T02 === 001 === === ===
=== === === T08 === === ===
=== === === === === === ===
=== === === === === === ===
SAVE AND EXIT(ESC TO CANCEL)
PRESS FUNCTION KEY AND ROTATE
JOYSTICK TO SELECT NUMBER.
xxxxx
===
SCAN TYPE
DWELL
003
A08
P01
T02
: 16 digits of title for tour label
: blank preset position
: Max (Normal)/ Slow V. Scan/ Fast V. Scan
: 03-99 Sec
: Preset 003 (1~240)
: Auto Scan 08 (1~8)
: Pattern 01 (1~4)
: Tour 02 (1~8)
Follow the steps below to program the Tours:
1. Press MENU to display the main menu on the monitor. Scroll to Tour and push the
Joystick to the right to enter the Tour menu. Or just press the Tour key on the keyboard
2. Choose an empty location to be programmed by pushing the Joystick up, down, right, or left.
3. To see a stored preset view, use the Joystick to move the cursor to a stored position. By pressing Prst key, the camera will move to the stored Preset view.
4. To add a stored preset as a Tour, twist the Zoom handle or press Zoom Key (Programmed preset will scroll). To remove a stored preset from the Tour, press the Home key, blank position mark (===) will be displayed. You can overwrite the programmed position.
5. To place functions other than preset, press Tour, Ptrn, or Scan for Tour, Pattern or Auto
Scan respectively.
6. Repeat Step 2 through 5 for each desired position. Each title will be displayed on top of the line.
7. Up to 36 Presets, Tours, Patterns Scans can be selected for a Tour. You can expand the
Tour sequence by calling other programmed tours. Push the Joystick handle to right or left while the cursor is on the top of the line (TOUR 01) to select another page of the Tour menu.
(TOUR 01)
8. You can enter a title for the selected Tour by twisting the Joystick while the cursor is on the top of the line (TOUR 01). Rotate the handle clockwise or counterclockwise to scroll through the alphanumeric characters. Push the handle to the right or left to select the next or previous digit.
9. Select Save and Exit by pushing the Joystick to the right. Press ESC to exit the program without saving.
NOTE: Press the Home key at a programmed position to delete programmed function.
In the Tour mode, in conjunction with preset and Auto Scan, you can make the camera travel from a preset position to another preset position at a specific speed.
Example : Preset 001>002>003>004>005>006, Auto Scan 01 starts at preset 002, ends at preset 003, Auto Scan 02 starts at preset 005, ends at preset 006; Tour01: 001, 002, A01, 004,
A02.
1 è 2 2~3 è 4 è 5~6, repeat where è : Quick move, ~ : Programmed speed
3.8 Pattern
(Fourth 4 Item of the Main menu / Shortcut: PTRN )
The Pattern feature records user control of the selected dome camera for up to 240 seconds. Up to four 4 patterns can be stored and played back by pressing No.+ PTRN keys subsequently.
PATTERN SETUP
NO. TITLE SEC
01 : xxxxxxxxxxxxxxxx 000
02 : xxxxxxxxxxxxxxxx 041
03 : xxxxxxxxxxxxxxxx 010
04 : xxxxxxxxxxxxxxxx 020
TOTAL 071
SAVE AND EXIT(ESC TO CANCEL)
HOLD DOWN CTRL KEY
WHILE RECORDING.
Follow steps below to program the Pattern:
1. Press MENU key to display the main menu on the monitor.
2. Scroll down to PATTERN and push the Joystick to the right. Or simply press the PTRN key rather than use the Main Menu.
3. Select the empty Pattern number to be programmed by pushing the Joystick Up or Down.
If last column is not 000, a pattern has already been recorded. Patterns can be over written.
4. Press and hold down the CTRL/PGM key while controlling the camera direction and zoom with the Joystick . Your controls will be automatically recorded until you release the
CTRL/PGM key. You can repeat this procedure until you have the pattern you want.
Previously recorded patterns will be overwritten each time you do this.
5. Scroll down to the Save and Exit option and push the Joystick to the right to save and exit.
6. You can title the selected Pattern by twisting the Joystick . Rotate the handle clockwise or counterclockwise to scroll through the alphanumeric characters, push the handle to right or left to select next or previous space.
7. Pressing ESC will not save your information and exits to the previous mode.
Press the HOME key at any programmed position to delete that programmed pattern.
NOTE: If total recording time reaches 240 seconds, it will automatically stop for a moment and restart recording. Previous data will be overwritten.
3.9 Alarm
(This menu shows on only specific model, Fifth Item of Main menu)
ALARM SETUP
NO PRI PRS IN OUT HLD LATCH
01 1 001 OFF OFF 3 OFF
02 0 A01 OFF OUT1 3 OFF
03 1 240 NO OUT1 3 OFF
04 2 001 NC OUT4 3 OFF
05 1 001 OFF OFF 3 OFF
06 8 001 OFF OUT1 3 OFF
07 1 240 NO OUT1 3 OFF
08 2 001 NC OUT4 3 OFF
SAVE AND EXIT(ESC TO CANCEL)
NO : Alarm input number
PRIO : Lower No. has higher priority, Equal priority alarms will be serviced repeatedly.
PRS : Stored preset number to be called by alarm.
IN : NO/NC - normally open /Closed OFF - ignore
OUT : OUT1~OUT4 - Relay out 1,2,3,4, OFF - No output.
HOLD : Alarm will be held for programmed time (03 to 99 seconds)
LATCH : ON - Shows all alarms including past alarm, OFF - Shows activated alarms only.
There are 8 levels of priority. “0” is the highest priority and can be selected Autoscan, Pattern or
Tour only. “1” - “8” can be selected Preset only. During responding “0” priority alarm, other alarms won’t be serviced until the “0” priority action is completed.
1. Press Menu to display the main menu on the monitor. Select the Alarm option by pushing the Joystick up or down and push to right to enter the detail menu.
2. Select the alarm input number by pushing the Joystick up or down and select the column you wish to setup. Selected position will be highlighted.
3. Select the Preset, Status of Input (NC/NO/OFF), and Output (OUT1~4/OFF) by pushing the
Joystick to the right or to the left.
4. To increase or decrease the preset number or to change the status or output number, twist the Joystick clockwise or counterclockwise. In case of preset, programmed preset number will be scrolled.
5. Select the Save and Exit option by pushing the Joystick up or down. Save and exit the program by pushing the Joystick to the right. Press ESC to exit the program without saving.
3.10 Area Title
(Sixth Item of Main menu)
Enter a specific name on programmed angle between START and END. For the screen below, when the camera points at an angle between 124.3
° to 359.5
° , ABC will be displayed on the screen.
AREA TITLE SETUP
NO TITLE START END
01 ABC 124.3 359.5
02 xxxxxxxxxxxxxxxx ===== =====
03 xxxxxxxxxxxxxxxx ===== =====
04 xxxxxxxxxxxxxxxx ===== =====
05 xxxxxxxxxxxxxxxx ===== =====
06 xxxxxxxxxxxxxxxx ===== =====
07 xxxxxxxxxxxxxxxx ===== =====
08 xxxxxxxxxxxxxxxx ===== =====
SAVE AND EXIT(ESC TO CANCEL)
HOLD DOWN CTRL KEY TO MOVE
PAINNING AND SET AREA ANGLE.
Pages can be scrolled through by pushing the Joystick to the Left or Right on the first or last column of the menu. Pushing the Joystick to left on the “NO” column (01 ~ 08) of the menu to scroll to the previous page. Push the Joystick to right on the “END” column to go to the next page.
1. Press MENU to display the main menu on the monitor. Select the Area Title option by pushing the Joystick up or down and push to right to enter the detail menu.
2. Select the area number by pushing the Joystick up or down. Select Start, End or number column to be set by pushing the handle to the right or left. The selected column will be highlighted.
3. To enter area title, select the number column and rotate the handle clockwise or counterclockwise. You can select alphanumeric characters by rotating the handle. Move to the next character by pushing the Joystick to the right. To finish entering the title, push the
Joystick down.
4. To adjust panning limit, press the CTRL/PGM key and hold down. Then use the Joystick to go the desired direction. The end limit must be in an increasing direction. (Start < End).
5. When you press the CTRL/PGM key, the current position of the pan will be printed in the highlighted column. With this feature, you can easily set the next start point as the previous end point.
6. Select the Save and Exit option by pushing the Joystick up or down. Save and exit the program by pushing the Joystick to the right. Press ESC to exit the program without saving.
Pressing the HOME key will delete programmed data. (Angles will be turned ==== immediately.)
3.11 Privacy Zone
(Seventh Item of Main menu)
Hide up to 8 unwanted views in a camera.
PRIVACY ZONE SETUP
NO TITLE METHOD
01 xxxxxxxxxxxxxxxx ON BLOCK
02 xxxxxxxxxxxxxxxx OFF V.OFF
03 xxxxxxxxxxxxxxxx NONE ====
04 xxxxxxxxxxxxxxxx NONE ====
05 xxxxxxxxxxxxxxxx NONE ====
06 xxxxxxxxxxxxxxxx NONE ====
07 xxxxxxxxxxxxxxxx NONE ====
08 xxxxxxxxxxxxxxxx NONE ====
SAVE AND EXIT(ESC TO CANCEL)
1. Press MENU to display the main menu on the monitor. Select the Privacy Zone option by pushing Joystick Up or Down and push to right to enter the detail menu.
2. Select the privacy zone number by pushing the Joystick up or down.
3. To enter the zone name, rotate the handle clockwise or counterclockwise. You can select alphanumeric characters by rotating the handle. Move to the next character position by pushing the Joystick to the right. To finish entering the title, push the Joystick down or press the ENTR key.
4. To adjust the “marked” (privacy) area, press and hold down the CTRL/PGM key and then use the Joystick (direction and zoom) until you get desired view. Release the key, the right column will be set to ON.
5. You can overwrite an existing zone. Use the Home key to delete the marked zone, or push the Joystick to the right or left to turn the stored zone On or Off.
6. Select the Save and Exit option by pushing the Joystick up or down. Save and exit the program by pushing the Joystick to the right. Press ESC to exit the program without saving.
Press the HOME key to delete programmed privacy zone.
3.12 Camera
(Eighth Item of Main menu)
NOTE: The menu features will vary depending on the camera module installed in your dome camera.
CAMERA SETUP
FOCUS CONTROL
WB CONTROL
AE CONTROL
LINE LOCK CONTROL
SHARPNESS : 10
BACK LIGHT : OFF
DIGITAL ZOOM : OFF (MAX)
NIGHT SHOT CONTROL
SAVE AND EXIT(ESC TO CANCEL)
SHARPNESS The higher the value, the more edges in the picture will be enhanced
User can adjust sharpness level from 0 to 20. Level 20 is default
BACK LIGHT Objects in front of bright backgrounds will be clearer with BLC ON.
Digital ZOOM OFF: Zoom range is limited to the optical.
MAX: Zoom is extendable Max digital Zoom range.
• FOCUS CONTROL
FOCUS SETUP
MODE : AUTO
EXIT(ESC TO EXIT)
MODE : AUTO / MANUAL
Use manual mode in normal use.
CAUTION: Avoid continuous, 24-hour use of the auto focus. This will shorten the lifespan of the lens.
• WB (White Balance) CONTROL
WB SETUP
MODE : AWB
R GAIN : 85
B GAIN : 85
EXIT(ESC TO EXIT)
MODE
WAWB
RGAIN
BGAIN
AWB / WAWB / INDOOR / DOUDOOR / MANUAL
Wide range auto white balance mode.
0 ~ 255
0 ~ 255
Use the AWB mode for normal use.
RGAIN / BGAIN modes are controllable only in MANUAL Mode
Push the Joystick to the right or left to change.
• AE CONTROL
AE SETUP
MODE : FULL AUTO
SLOW SHUTTER : AUTO
IRIS : F1.6
GAIN : 2DB
BRIGHT : 30
SHUTTER : AUTO
WDR MODE : ON EXIT (ECS TO
EXIT)
MODE FULL AUTO / SHUTTER PRIO / IRIS PRIO / AGC / MANUAL
SLOW SHUTTER AUTO / OFF / ON (MANUAL, SHUTTER PRIO MODE ONLY)
IRIS
GAIN
BRIGHT
SHUTTER
CLOSE, F1.6 / F2.0 / F2.8 / F4.0 / F5.6 / F8.0 / F11 / F16 / F22 / F32
OFF, 2, 4, 6, 8, 10, 12, 14, 16, 18, 20 DB
User can adjust brightness level (0~ +90). Level 30 is default.
1/1, 1/2, 1/3, 1/6, 1/10, 1/30, 1/60, 1/100, 1/125, 1/250, 1/500, 1/1000,
WDR MODE
1/2000, 1/5000, 1/10,000
(1/1, 1/2, 1/3, 1/6, 1/12, 1/25, 1/50, 1/100, 1/120, 1/250, 1/500, 1/1000,
1/2000, 1/4000, 1/10,000)
Wide Dynamic Range Technology uses two shutter speeds in alternative video fields-high and normal- every 60th (or 50th) of a second and combines two fields into one progressive scan frame. It allows every detail to be captured accurately even if one portion of an image is brilliantly bright while other portions are dark.
NOTE : Values in ( ) are for PAL Camera.
• LINE LOCK CONTROL
LINE LOCK SETUP
MODE : INTERNAL
PHASE : 125
EXIT(ESC TO EXIT)
MODE
PHASE
EXIT (ESC TO EXIT)
INTERNAL / EXTERNAL Adjusts phase of picture with other
0~255 cameras in EXTERNAL mode.
• NIGHT SHOT MENU
The NIGHT SHOT option removes the IR cutoff filter of the camera and makes the camera sensitive to near infrared.
NIGHT SHOT SETUP
MODE : MANUAL
LOCAL CONTROL : OFF
EXIT(ESC TO CANCEL)
MODE: MANUAL / AUTO / GLOBAL
AUTO: Camera goes in to B&W mode at low light.
GLOBAL: Controlled by the keyboard.
The operator can enable NIGHT SHOT for all dome cameras at the same time.
If the NIGHT SHOT mode is set to GLOBAL, “999” + ENTR/GLBL will turn Off the NIGHT
SHOT mode and “888” + ENTR/GLBL will turn On the NIGHT SHOT mode.
MANUAL: Controlled by the local setting value.
LOCAL CONTROL: ON/OFF will enable and disable Night Shot mode of an individual camera.
3.13 Dome Setup
(Ninth Item of Main menu)
CONFIGURATION MENU
LANGUAGE SETUP
HOME FUNCTION SETUP
OSD DISPLAY
VIEW ANGLE SETUP
INITIALIZE DATA
ORIGIN OFFSET
DOME RESET
SYSTEM INFORMATION
EXIT(ESC TO EXIT)
• LANGUAGE SETUP
LANGUAGE SETUP
LANGUAGE : ENGLISH
SAVE AND EXIT(ESC TO CANCEL)
LANGUAGE : Select the language you want.
* This setup displays more than 3.0 of the ROM version.
• HOME FUNCTION SETUP
After a dome control menu item has been selected, follow the directions below to set the function.
HOME FUNCTION SETUP
HOME FUNCTION : NONE
FUNCTION NUMBER : ---
WATING TIME : 120 SEC
FUNCTION ENABLE : OFF
SAVE AND EXIT(ESC TO CANCEL)
HOME FUNCTION
FUNCTION NUMBER
WAITING TIME
FUNCTION ENABLE
: None/ Preset/ Tour/ Pattern/ Auto Scan
: xxx
: 10~240 Seconds
: ON/ OFF
The Home function can be set so that the camera automatically goes to Preset, Tour, Pattern,
Auto Scan after the keyboard controller has been idle for a amount of time. For example, if the
Joystick controller is idle for 10 seconds, the camera goes to preset 1.
Follow these steps to program the Home position:
1. Press MENU to display the main menu on the monitor.
2. Select Home Function by pushing the Joystick to the right or to the left to scroll through the
None, Tour, Pattern, Auto Scan and Preset functions.
3. Select Function Number by pushing the Joystick down, and push the Joystick to the right or to the left. The executable function number will scroll. Each function has maximum numbers. For example, you can have 240 Presets, 8 Tours, 4 Patterns and 8 Auto Scan options.
4. Select Function Time by pushing the Joystick down. Push the Joystick to the right or to the left to select from 10 to 240 seconds.
5. Select Function Enable by pushing the Joystick down. Turn the Home Enable ON or OFF by pushing the Joystick to the right or to the left.
• OSD DISPLAY
DISPLAY SETUP
CAMERA TITLE : DOMEID
VIEW DIRECTION : OFF
DOME OSD DISPLAY : ON
AREA DISPLAY : OFF
SAVE AND EXIT(ESC TO CANCEL)
CAMERA TITLE
VIEW DIRECTION
DOME OSD DISPLAY
AREA DISPLAY
• VIEW DIRECTION
: 8 CHARACTER CAN BE SET
: ON / OFF
: ON / OFF
: ON / OFF
“ON” sets current direction as N(north) and the coordinate angle to 000. “OFF” hides the directional title. Every 90 degrees of clockwise rotation will change the title to E(East), S(South),
W(West). If using the ON/OFF option frequently, it is recommended that you set “North” as a
Preset. Recall the “North” Preset before enabling the directional title.
• DOME OSD DISPLAY
All display or title will disappear when DOME OSD DISPLAY sets OFF
• AREA DISPLAY
If this option is enabled, the nearest area title will be displayed when the camera is moving whether by manual operation, Auto Scan, or Pattern. Select ON or OFF by pushing the Joystick to the right or to the left. The Dome camera’s OSD will override this function (Dome camera’s
OSD must be enabled).
• VIEW ANGLE SETUP
VIEW ANGLE SETUP
PANNING RANGE
FLIP : ON
TILT OVER ANGLE : W/O BUBBLESAVE
AND EXIT(ESC TO CANCEL)
• PANNING RANGE
When the dome camera is installed near a wall, panning range can be limited by user.
PANNING RANGE SETUP
RIGHT LIMIT : 000.0
LEFT LIMIT : 000.0
ENABLE : OFF
SWAP RIGHT/LEFT
SAVE AND EXIT(ESC TO CANCEL)
• FLIP
Allows the dome camera to automatically turn 180 degrees when the camera tilts to its lower position.
When the camera reaches the floor directly above the moving object, it will stop. Release the
Joystick handle instantly and then pull down to run the flip function. The tracking speed will be the same as previous.
• TILT OVER ANGLE
This option is used to set the limit of the horizontal view angle so that the trim ring or ceiling does not obstruct the horizontal image when zooming out (wide angle).
ON : In some installations it is desirable for the dome camera to be able to see above the horizon. When this option is chosen, the dome will tilt up over the horizon(About -10 degrees). When the lens is zoomed out, you can see the ceiling line. But when the lens is zoomed in, the viewing angle is narrower, and the ceiling line disappears.
Without Bubble : The tilt range of the camera is limited to see the horizon so the picture shows part of the ceiling line.
With Bubble : The tilt range of the camera is limited to see below the horizon (10 degrees).
Over Angle is not sufficient enough to avoid ceiling obstructions, please adjust Origin Offset of tilt angle as described below.
• INITIALIZE DATA
INITIALIZE DATA
FACTORY DEFAULT
ERASE PROGRAMMED DATA
EXIT(ESC TO EXIT)
Erase all stored data from the Flash-ROM of the selected dome camera. You will be asked to enter Yes or No. If you intend to erase all data then press the MENU key, otherwise press the
ESC key to exit without erasing. The erased data includes all stored data (titles, presets, and tours….) except origin offset.
The offset value is still valid after all data is erased. The offset value can be zeroed only with default set of Offset origin menu.
CAUTION: All the data in the selected dome camera will be lost unless you download the data into a safe place. (Refer to Download/ Upload data function in the
Keyboard Configuration utility.) Data from the selected dome camera can be stored in the keyboard controller temporarily. If you want to save the data of all installed dome cameras, you need a special I/O interface and software for PC.
• ORIGIN OFFSET
This feature is useful to align a new dome camera exactly the same as the previously installed dome camera.
Dome camera’s origin set and all data initialize option do not override offset values. Only the default set option in this menu will set the offset value to zero. This can be used to avoid ceiling obstructions.
• DOME RESET
This feature is used to re-calibrate the orientation of a selected dome camera. Origin offset value is not affected by this function. (Offset is still valid after origin set)
• SYSTEM INFORMATION
SYSTEM INFORMATION
CAMERA TYPE : XXXXXXX
H/W VERSION : V1.0
ROM VERSION : V1.0
PROTOCOL : F2E
BUADRATE : 9600BPS
EXIT(ESC TO EXIT)
A Dome camera’s Setup menu provides essential information about the dome camera if service is required. When you view this screen, you can determine the camera type, ROM version.
The information on this screen cannot be modified.
Appendix A — Specifications
Camera
Image Sensor
Picture elements
Horizontal Resolution
Lens
View angle
Minimum Illumination
S/N ratio
WDR
1/4" Super-HAD Color CCD
NTSC : 768 x 494 Approx. 380K pixels
PAL : 752 x 582 Approx. 440K pixels
480 / 470 lines (NTSC / PAL)
22x optical zoom with auto focus
11x digital zoom
F1.6 to F3.6, f=3.9mm to 85.8mm
Approx. 49.5
° (WIDE end) to 2.4
° (TELE end)
1.0 lux (F1.6,normal shutter speed)
0.02 lux (F1.6,Low shutter on)
0.002 lux (F1.6 Low shutter on with IR Cut Filter Removed) more than 52dB
ON/OFF
General
Certification
Electrical
Input Voltage
Power Requirement
Power Consumption
Alarm Output
Alarm Input
Control
Access Time
ID (Camera Address)
Mechanical
Dimension
Weight
Pan Angle
Speed
Repeatability
Flip
Autoscan
Preset Position
Tour
CE EMC, FCC CLASS A, CSA
18 to 30VAC; 24VAC nominal, 24VDC
24VAC/VDC 1A
Maximum 20W
4 Normal relays 24VDC/1A Max. (selectable NC/NO)
8 Normal dry contact (selectable NC/NO)
RS-485/422 baud rate: 2400~230k bps (default: 9600bps)
0.75 second maximum preset recall time
999 (Factory mode selectable over 999 camera)
See Figure 10
Approx 1.2 kg
360 ° continuous rotation
0.1
° to 90 ° /sec. (proportional to zoom)
360 ° /sec. maximum (with CTRL/PGM key pressed)
Preset Speed: 380 ° /sec
0.2
°
Rotate 180 ° at bottom of tilt
8 auto scan include vector scan
240 positions with camera status (16-character title)
8 tours
Pattern
On-Screen Display
Environment
Operating temperature
Operating humidity
Storage temperature
Four patterns, 240 second
Displays camera ID and area name on screen
0 ° C to 50 ° C (32 ° F to 122 ° F)
0 to 90%RH (non-condensing)
-20 ° C to 60 ° C (4 ° F to 140 ° F)
Specifications are subject to change without notice.
Figure 10 – Dimension
Appendix B — Troubleshooting
If problems occur, verify the installation of the camera with the instructions in this manual and with other operating equipment. Isolate the problem to the specific piece of equipment in the system and refer to the equipment manual for further information.
No video.
Problem
Poor video quality.
Dome cameras lose their positions.
Camera number does not match the multiplexer number.
Picture is torn when switching
Possible Solution
Verify that power is connected to all pieces of equipment in the system.
Verify that the power switches are in the ON position.
Check the video connections
(see Figure 4).
Check that the BNC connectors are inserted properly.
Check the voltage level of the dome camera.
Check that 8-pin cable is connected to the Keyboard.
8-pin cable for Keyboard is proprietary. Cable for video is shielded.
Reset the cameras using the Dome configuration menus.
Check that the dome cameras are inserted properly in the base.
Check the voltage level of the dome camera.
Check the camera ID and insert the BNC cable into the proper input of the multiplexer.
Check Line Lock setting and adjust phase of L/L
Appendix C — Glossary
Alarm Actions
The assigned responses for the dome camera when inputs change from normal to abnormal states. The dome may run a Preset, Pattern, or have no assigned action for each of the four dome inputs. The dome may also send alarm states to the host controller for processing. See also Input and Normal Input State.
Areas
Programmed start and end points of the dome's field of view around its pan axis.
Each area is a part of a circular viewing area that extends around the dome. The areas can be different sizes. Up to 16 areas can be programmed for the dome.
Automatic Gain Control (AGC)
Allows for the amplification of the video signal in scenes with minimal ambient light. Many lowlight scenes result in picture noise. As gain is increased, the picture noise is also amplified.
When AGC is enabled, the value of the gain setting is based on feedback from the camera.
When AGC is disabled, the camera uses the value set for the manual gain setting. The trade-off between picture level and noise may be adjusted when AGC is disabled.
On-screen Menu
The text overlay menu system used for setting dome features. The utility is accessed using a keystroke combination. The utility provides settings for camera functions, zoom, alarms, text display, and password protection.
Flip
Allows the dome to automatically turn 180 degrees when the camera tilts to its lower limit and stays in that position for a brief delay. When the dome flips (rotates), the camera starts moving upward as long as the tilt control is kept in the down position. Once the control is released, the tilt control returns to its normal operational mode. The flip feature is useful when you need to track someone who walks directly beneath the dome and continues on the other side.
Home Position
The default position to which the dome camera returns after an assigned period of inactivity passes. The default position may be a Preset, Tour, Pattern, or No Action.
Input Alarm
A connection point on the dome camera that enables the system to monitor Input Devices. There are four inputs available for the dome camera.
Input Devices
External devices that provide information about the condition of system components that connect to the inputs on the dome camera. Typical input devices include door contacts, motion detectors and smoke detectors.
IR Mode
A feature of the camera that permits manual or automatic switching between color and IR
(black-and-white) operation. When IR mode is active, clearer images may be obtained under low-light conditions.
Line Lock
Allows you to phase lock the video with the AC power line. When line lock is enabled, it prevents vertical video rolling when switching multiple cameras to a single monitor. If text appears slightly tinted on color monitors, disabling the line lock may prevent this problem.
Name Information
Relates to the display the dome name, the area where the dome is pointing, the name of the preset or pattern that is running, and alarm names. The display of each type of name setting can be enabled or disabled. When the display of camera or area title(name) is enabled, the information appears on the screen continuously. Preset, tour and pattern titles(names) appear only while they are active.
Normal Input State
Describes the expected state of a device connected to one of eight dome camera’s inputs. The normal state may be open or closed. When a device is not in its normal input state, an alarm is issued.
North Position
User-definable setting that may correspond to magnetic north or some well-known landmark.
Used to approximate the camera dome's pointing direction when Direction Indicators are enabled.
Low Shutter
Setting used to improve the quality of video obtained in extreme low-light situations. When the
Low Shutter setting is enabled, low-light information is collected over multiple fields based on the
Shutter Limit setting. As a result, video may appear blurred or choppy in extreme low-light situations. This setting does not effect camera operation in normal lighting situations. See also
Automatic Gain Control (AGC).
Pattern
A series of pan, tilt, zoom and focus movements from a single programmable dome. Up to 8 patterns may be programmed for the dome camera.
Preset
Programmed video scene, based on a specific pan, tilt, zoom, and focus settings. Up to 240 presets may be programmed for the dome camera.
Privacy Zones
Masked areas of the dome camera's viewing area. These masks prevent operators of the surveillance system from viewing these designated zones. The Privacy Zones move in relation to the dome camera’s pan/tilt position. In addition, the apparent size of the Privacy Zone adjusts automatically as the lens zooms in or out. Up to eight Privacy Zones may be established for a dome camera.
Shutter Limit
Setting used to define the maximum exposure time for the Open Shutter setting. The values for the setting range from 1/2 to 1/60. The default setting is 1/4.
Vector Scan
Move from start point to end point including tilt and zoom simultaneously and linearly.
WDR
Wide Dynamic Range Technology uses two shutter speeds in alternative video fields-high and normal- every 60th (or 50th) of a second and combines two fields into one progressive scan frame. It allows every detail to be captured accurately even if one portion of an image is brilliantly. Whether at the high shutter speed or normal shutter speed, the progressive scan CCD provides a horizontal resolution of 470 lines. As a result, combined fields yield a frame of highquality images.
White balance
Adjustments in the color hue(red and blue) gains for a camera so that true white appears white in the image. It is normally compensated for by the automatic gain control. In some lighting conditions, you may need to manually adjust the red and blue settings for optimal viewing. When
Automatic White Balance is enabled, the camera measures the image and automatically adjusts the red and blue settings to balance white. When Automatic White Balance is disabled, the camera uses the values set for the red and blue settings to balance white.
Appendix D — Short Cut Key
Short Cut Key
PRST
Function
Pop up preset setup menu.
TOUR
PTRN
SCAN
Pop up Pattern setup menu.
Pop up Auto Scan setup menu.
NO.+ PGM + PRST Store the current view at the selected number.
1 ~ 4 + ON
1 ~ 4 + OFF
10 + ON
10 + OFF
11 + ON
11 + OFF
12 + ON
12 + OFF
13 + ON
13 + OFF
14 + ON
14 + OFF
15 + ON
15 + OFF
100 + ON
101 + ON
102 + ON
103 + ON
104 + ON
104 + OFF
Pop up guard Tour setup menu.
Turn On Relay.
Turn Off Relay.
Night Shot on
Night Shot off
BLC on
BLC off
Digital Zoom on (According to digital zoom setting)
Digital Zoom off
Dome OSD on
Dome OSD off
Dome Area Title Display on
Dome Area Title Display off
View Direction on
View Direction off
Shutter speed auto
Shutter speed 1/4 (PAL 1/3)sec
Shutter speed 1/2 sec
Shutter speed 1 sec
WDR on
WDR off
* Some function may not operate according to the model.
advertisement
Related manuals
advertisement
Table of contents
- 7 1.1 Features
- 9 2.1 Package Contents
- 10 2.2 Basic Configuration of Fastrax II E Dome Camera System
- 11 2.3 Setting Dome Camera Termination
- 13 2.4 Setting Dome Camera Address (ID)
- 14 2.5 Setting Dome Camera Protocol
- 15 2.6 Connections
- 15 Connecting to the RS
- 15 Connecting Video out connector
- 15 Connecting Alarms
- 15 Connecting the Power
- 15 2.7 Getting Started
- 17 3.1 Dome Camera Selection
- 17 3.2 Accessing On-Screen Menu Utility
- 18 3.3 How to control On-Screen Menu Utility
- 18 3.4 Auto Scan
- 20 3.5 Preset
- 21 3.6 Shortcut Preset Program
- 21 3.7 Tour
- 23 3.8 Pattern
- 24 3.9 Alarm
- 25 3.10 Area Title
- 26 3.11 Privacy Zone
- 33 3.12 Camera