The ABSCO SHEDS A30231GK is a birdcage-style shed made of steel sheets and mesh. The shed has a front, side and height of 3.00m, 2.22m and 2.10m respectively. It is easy to assemble with pre-assembled parts, requires minimal tools and hardware. The shed provides ample space for storage or other purposes, and its durable construction ensures longevity.
advertisement
Absco Industries
Aviary Model: A30231GK
FRONT: 3.00m
SIDE : 2.22m
HEIGHT: 2.10m
2320
CONCRETE SLAB
3100mm
WHEN LAYING YOUR CONCRETE
SLAB, ENSURE THERE IS A
REBATED EDGE 25mm DEEP
AROUND THE PERIMETER
THIS WILL HELP WATER EGRESS
FROM THE BASE OF THE SHED
CONCRETE
BOTTOM CHANNEL
REBATED EDGE
75mm WIDE REBATE
CONCRETE SLAB
We thank you for choosing an Australian made shed. For further assistance please visit our detailed instructional video library at
Http://www.abscosheds.com.au/watch-videos
At ABSCO Industries we are always looking to be number ONE, so please let us know what you think of our instructions. Feedback makes us better.
ABSCO INDUSTRIES ASSEMBLY INSTRUCTION MANUAL AVIARY MODEL: A30231GK 06-02-2018 PAGE 01
Absco Industries
Aviary Model: A30231GK
GENERAL INSTRUCTIONS
· Before commencing any assembly, read through these instructions in detail to gain a thorough understanding of assembly methods and associated details.
· Unpack the carton and carefully identify and check off all the parts against the parts described and illustrated on pages three and four.
SITE PREPARATION
· The site for the shed must be level. An uneven surface may result in misalignment of parts.
· It is recommended that the shed be set on a 100mm concrete slab and anchored down appropriately (refer to last page for details).
· Anchor sets are not supplied as standard items with this product as some customers wish to use their own anchoring systems.
TOOLS REQUIRED TOOLS OPTIONAL
10mm
(Steel)
10mm
(Masonary)
A NOTE ON SAFETY
· Some parts may have sharp edges. It is advisable to wear gloves when handling these items and safety glasses if drilling holes. Sensible shoes are highly recommended.
· Do not erect your shed in windy conditions, ensure that the shed is securely anchored to a solid foundation immediately after construction is completed.
· It is highly recommended to erect the shed with two or more people.
ABSCO INDUSTRIES ASSEMBLY INSTRUCTION MANUAL AVIARY MODEL: A30231GK 06-02-2018 PAGE 02
Absco Industries
Aviary Model: A30231GK
QTY
4
COMPONENTS PACKING LIST - CHECK OFF ALL COMPONENTS
COMPONENT
DESCRIPTION
PART
No.
CHECK QTY
STEEL SHEET
1785mm X 773mm
30A
5
COMPONENT
DESCRIPTION
MESH SHEET
1220mm X 712mm
PART
No.
CHECK
-
2
STEEL SHEET
1785mm X 773mm
31A
1
MESH SHEET
590mm X 712mm
-
6
2
3
1
STEEL SHEET
1546mm X 773mm
45A
STEEL SHEET
1785mm X 731mm
33A
STEEL SHEET
585mm X 773mm
154
STEEL SHEET
585mm X 773mm
154L
STEEL SHEET
585mm X 773mm
154R 1
2
BRACE
L: 393mm
1
FITTINGS AND
ACCESSORIES
(SEE PAGE 5)
13A
1
PRE-ASSEMBLED
DOOR
-
1
1
RIDGE
BEAM
L = 1152mm
97BL
RIDGE
BEAM
L = 1152mm
97BR
1
2
RIDGE BEAM JOINER
L: 450mm (17.7")
GABLE L/H
L=1475mm
ZARSP
16L
2
GABLE R/H
L=1475mm
16R
1
A30231GCP
CHANNEL PACK
(SEE PAGE 4)
ABSCO INDUSTRIES ASSEMBLY INSTRUCTION MANUAL AVIARY MODEL: A30231GK 06-02-2018 PAGE 03
Absco Industries
Aviary Model: A30231GK
QTY
COMPONENTS PACKING LIST - CHECK OFF ALL COMPONENTS
COMPONENT
DESCRIPTION
PART
No.
CHECK QTY
COMPONENT
DESCRIPTION
PART
No.
CHECK
2
CHANNEL
L = 1496.5mm
160L
2
CHANNEL
L = 1496.5mm
160R
1
CHANNEL
L = 1496.5mm
1
CHANNEL
L = 1496.5mm
2
CHANNEL
L = 1126.5mm
2
CHANNEL
L = 1105mm
77BL
81BL
81CL
168L
1
CHANNEL
L = 1496.5mm
1
CHANNEL
L = 1496.5mm
2
CHANNEL
L = 1126.5mm
2
CHANNEL
L = 1105mm
77BR
81BR
81CR
168R
2
CHANNEL
L = 1105mm
2
CHANNEL
L = 1126.5mm
13
CHANNEL
L = 712mm
2
CHANNEL
L = 1745mm
11
JAMB L= 1785mm
169L
78BL
181
172
191
2
CHANNEL
L = 1105mm
2
CHANNEL
L = 1126.5mm
1
JAMB L= 1785mm
1
JAMB L= 712mm
4
LIP TRIM L= 1546mm
169R
78BR
192
195
87B
ABSCO INDUSTRIES ASSEMBLY INSTRUCTION MANUAL AVIARY MODEL: A30231GK 06-02-2018 PAGE 04
Absco Industries
Aviary Model: A30231GK
COMPONENTS PACKING LIST - (CONT.) CHECK OFF ALL COMPONENTS
2
CONTENTS OF FITTINGS PACKET
CAP GABLE
L: 170mm
14A
1 ASSEMBLY
INSTRUCTIONS
12
10
1
1
1
6
CHANNEL JOINER
L= 200mm (7.9")
CSJ
1
SINGLE DOOR
FITTINGS PACK
PSTKSGL
16mm TEK
SCREWS
FAST014 100
LARGE FLANGE
POP-RIVETS
PSTKSGL - SINGLE DOOR FITTINGS PACK
DOOR
PADBOLT
3mm DRILL BIT
FAST006
DRILL
1
1
DOOR
PADBOLT
HASP
FAST007
PHILLIPS DRIVER BIT
FAST038
SELF TAPPING SCREWS
PACKET CONTAINING 220
1
PACK 6P - SCREW PACK 6
3/16 COUNTERSUNK
SCREWS & NUTS
6
PACK 6P
SCREW PACK 6
3.2 x 8mm
BLIND POP RIVETS
ABSCO INDUSTRIES ASSEMBLY INSTRUCTION MANUAL AVIARY MODEL: A30231GK 06-02-2018 PAGE 05
Absco Industries
Aviary Model: A30231GK
INSTRUCTIONS FOR JOINING SPLICED CHANNELS
NOTE: THE TEXT MARKED ON ALL PARTS MUST BE SHOWN ON THE SAME SIDE AS EACH OTHER.
=
JOIN>>
CSJ
=
<<JOIN
=
JOIN>>
J
=
=
JOIN>> SJ
=
STEP 1.
Position the channels and the CSJ joiner channel so the center of the
CSJ is in line with the end of each channel to be joined together.
STEP 2.
Join the first channel to the CSJ by inserting the center of the CSJ (on an angle) to the end of the channel where the JOIN>> text is marked. Push down one side of the CSJ until you hear a 'click'.
=
JOIN>>
=
<<JOIN
JOIN>>
=
<<JOIN
=
STEP 3.
Join the second channel to the CSJ by positioning the <<JOIN end of the channel at the center of the CSJ
(on an angle). Push the CSJ into the channel until you here a 'click'.
FINISHED CHANNEL
The joined channels should now look like the picture above with the
CSJ positioned equally inside of the joined channels.
DRILL 4 x 3mm (2 PER A SIDE)
HOLES TO SECURE SECTIONS
TOGETHER.
(THESE SCREWS MAY HAVE TO
BE TEMPORARILY REMOVED
AND REPLACED DURING LATER
ASSEMBLY)
QTY = 10pcs.
CSJ
CSJ CSJ CSJ
CSJ
HIGH-SIDE
LOW-SIDE
CHANNEL
CHANNEL
ABSCO INDUSTRIES
20mm
CHANNEL
15mm
CSJ
CHANNEL
ASSEMBLY INSTRUCTION MANUAL AVIARY MODEL: A30231GK 06-02-2018 PAGE 06
Absco Industries
Aviary Model: A30231GK
STEP 1. PRE-ASSEMBLY OF SPLICED CHANNELS
NOTE: JOIN TOGETHER 24 X CHANNEL SECTIONS USING 12 X CHANNEL JOINERS (PART CSJ)
NOTE: SOME CHANNELS HAVE
HOLES IN THEM - YOU WILL NEED
TO RE-DRILL HOLES ON ANY
CHANNEL WHERE THE CSJ
JOINING CHANNEL COVERS
HOLES ON THE CHANNELS
YOU ARE CONNECTING
2993mm (117.8")
81BR
=
=
1 x 81B
1 x 77B
77BR
= 2 x 160
81BL
160R
1 X 81BR
1 X 81BL
77BL
= 2 x 81C
1 X 77BR
1 X 77BL
2 X 160R
2 X 160L
160L
2253mm (88.7")
81CR
78BR
= 2 x 78B
81CL
2 X 81CR
2 X 81CL
= 2 x 168
78BL
168R
2 X 78BR
2 X 78BL 2210mm (87")
= 2 x 169
169R
168L
2 X 168R
2 X 168L
2 X 169R
2 X 169L
ABSCO INDUSTRIES
169L
ASSEMBLY INSTRUCTION MANUAL AVIARY MODEL: A30231GK 06-02-2018 PAGE 07
Absco Industries
Aviary Model: A30231GK
INSTRUCTIONS FOR JOINING SPLICED RIDGE BEAM
STAGE 1: PUSH RIDGE BEAMS TOGETHER, MAKE SURE THERE IS A 50mm OVERLAP
OF THE RIDGE CAP
STAGE 2: INSERT RIDGE CAP JOINER INTO CONNECTED RIDGE CAPS.
MAKE SURE JOINER HAS 225mm IN EACH RIDGE CAP.
STAGE 3: TURN RIDGE CAP OVER AND MEASURE 250mm FROM THE END OF EACH RIDGE
CAP.
PLACE TEK SCREWS IN 50mm INCREMENTS FROM SAID END.
REPEAT THIS PROCESS FOR THE OPPOSING HALF OF RIDGE BEAM
ABSCO INDUSTRIES ASSEMBLY INSTRUCTION MANUAL AVIARY MODEL: A30231GK 06-02-2018 PAGE 08
QTY. = 1
QTY. = 8
QTY. = 2
Absco Industries
Aviary Model: A30231GK
STEP 2. PRE-ASSEMBLY OF SPLICED RIDGE BEAM
PHILLIPS DRIVER BIT
SELF DRILLING TEK SCREW
RIDGE BEAM 1126.5mm
PARTS 97BL & 97BR
QTY. = 1
PART ZARSP - 450mm LONG
16mm
ZARSP
200mm
250mm
97BR
16mm
ABSCO INDUSTRIES
97BL
THE TOP SECTIONS OF
CAPPING WILL OVERLAP
EACH OTHER AT THE
JOIN BY 50mm.
(PART 97B)
2253mm OVERALL LENGTH
ASSEMBLY INSTRUCTION MANUAL AVIARY MODEL: A30231GK 06-02-2018 PAGE 09
Absco Industries
Aviary Model: A30231GK
ABSCO INDUSTRIES ASSEMBLY INSTRUCTION MANUAL AVIARY MODEL: A30231GK 06-02-2018 PAGE 10
16L
16R
16R
16L
Absco Industries
Aviary Model: A30231GK
ABSCO INDUSTRIES ASSEMBLY INSTRUCTION MANUAL AVIARY MODEL: A30231GK 06-02-2018 PAGE 11
Absco Industries
Aviary Model: A30231GK
ABSCO ASSEMBLY INTRODUCTION
The snaptite assembly system locks most perimeter channels to all roof and wall sheets without the need for tools and fasteners.
SNAP
To pre-assemble the four wall panels and two roof panels, the perimeter channels are secured to the top and bottom of each panel using the snaptite system, as detailed on the following pages wherever you see the symbol.
SNAP
HIGH SIDE
After joining sheets together, position channel over one end of the sheets, gently tapping it over the snaptite lugs, working along the sheets to the other end.
PUSH
PUSH
Position sheets on timbers, trestles or partly over edge of concrete slab.
HIGH SIDE
Each perimeter channel must finish flush with the edges of the sheets.The snaptite system allows adjustment for this process by simply tapping the channel along the sheets until each end is neatly flush. If you need to remove channels from the panels, pull the channel along the panel from
FASTENING SYMBOLS
D opposing ends. You may need someone to help with this.
Join components together by pre-drilling the holes first. Use one component as a template to mark where 3mm POP RIVETS the holes are. Drill with 3mm drill bit.
4mm NUT & BOLT SET
Join components together with one screw at this location only, as some channel sections have extra holes that are not required for this model of garden shed
Do not join components together at this location yet, as the screw may obstruct further assembly of other components
ABSCO INDUSTRIES ASSEMBLY INSTRUCTION MANUAL AVIARY MODEL: A30231GK 06-02-2018 PAGE 12
Absco Industries
Aviary Model: A30231GK
REAR PANEL ASSEMBLY
30A
31A
31A
30A
77B
SNAP i
SNAP i
81B
ABSCO INDUSTRIES ASSEMBLY INSTRUCTION MANUAL AVIARY MODEL: A30231GK 06-02-2018 PAGE 13
Absco Industries
Aviary Model: A30231GK
ROOF PANEL ASSEMBLY
(2 Required)
45A
45A
SNAP i
78B
45A
87B
2 x PRE-PUNCHED
HOLES TO THIS
END OF EACH
SHEET WITH PART
NO. 81C FITTED
81C
SNAP i
87B
ABSCO INDUSTRIES ASSEMBLY INSTRUCTION MANUAL AVIARY MODEL: A30231GK 06-02-2018 PAGE 14
Absco Industries
Aviary Model: A30231GK
SIDE PANEL ASSEMBLY
LEFT HAND SIDE 169
SNAP i
181
SMALL PAN
THIS SIDE
191
191
181
172
154
33A
30A
STEP 2.
JOIN THE TWO SHEETS
TOGETHER (30A & 33A) AT
PRE-PUNCHED LOCATIONS AND
FIT THE TOP AND BOTTOM
CHANNELS (168 & 169). ENSURE
THAT THE PRE-PUNCHED HOLES
IN THE CHANNELS ARE LOCATED
AT THE RIGHT HAND END FOR
CONNECTING THE REMAINING
JAMB AND CORNER MULLION. THE
TOP AND BOTTOM CHANNELS
WILL EXTEND PAST THE CORNER
MULLION BY 3mm.
SNAP i
STEP 1.
JOIN THE JAMB AND
CHANNEL SECTIONS
(191 & 172) TOGETHER
AT PRE-PUNCHED
LOCATIONS TO FORM
THE CORNER MULLION.
THE CHANNEL SECTION
WILL FINISH 20mm
SHORT OF THE JAMB AT
EACH END.
168
SMALL EDGE
STEP 1.
ABSCO INDUSTRIES
STEP 3.
SCREW THE FRAME TOGETHER
AS SHOWN AT PRE-PUNCHED
LOCATIONS. ADDITIONAL HOLES
IN THE JAMB SECTIONS DO NOT
REQUIRE SCREWS.
ASSEMBLY INSTRUCTION MANUAL AVIARY MODEL: A30231GK 06-02-2018 PAGE 15
SIDE PANEL ASSEMBLY
SNAP i
181
STEP 4.
Absco Industries
Aviary Model: A30231GK
LEFT HAND SIDE (CONTINUED)
NOTCHED CORNERS TO
BOTTOM OF SHEET
154
LAY THESE SECTIONS OVER
THE PANEL AS SHOWN,
LOCKING THE SHEET INTO
THE BOTTOM CHANNEL.
SNAP i
MOVE THE TOP INFILL
CHANNEL (181) INTO
POSITION.
181
SNAP i
D
D
D
D
D
D
D
ABSCO INDUSTRIES ASSEMBLY INSTRUCTION MANUAL AVIARY MODEL: A30231GK 06-02-2018 PAGE 16
SIDE PANEL ASSEMBLY
RIGHT HAND SIDE
172
154L
Absco Industries
Aviary Model: A30231GK
181
168
191
181
191
SMALL PAN
THIS SIDE
33A
SNAP
30A
SMALL EDGE
169
SNAP
STEP 1.
JOIN THE JAMB AND
CHANNEL SECTIONS
(191 & 172) TOGETHER AT
PRE-PUNCHED LOCATIONS
TO FORM THE CORNER
MULLION. THE CHANNEL
SECTION WILL FINISH 20mm
SHORT OF THE JAMB AT
EACH END.
STEP 1.
STEP 2.
JOIN THE TWO SHEETS TOGETHER
(30A & 33A) AT PRE-PUNCHED
LOCATIONS AND FIT THE TOP AND
BOTTOM CHANNELS (168 & 169).
ENSURE THAT THE PRE-PUNCHED
HOLES IN THE CHANNELS ARE
LOCATED AT THE LEFT HAND END
FOR CONNECTING THE REMAINING
JAMB AND CORNER MULLION.
THE TOP AND BOTTOM CHANNELS
WILL EXTEND PAST THE CORNER
MULLION BY 3mm.
STEP 3.
SCREW THE FRAME TOGETHER AS SHOWN AT PRE-PUNCHED LOCATIONS. ADDITIONAL HOLES IN
THE JAMB SECTIONS DO NOT REQUIRE SCREWS.
ABSCO INDUSTRIES ASSEMBLY INSTRUCTION MANUAL AVIARY MODEL: A30231GK 06-02-2018 PAGE 17
SIDE PANEL ASSEMBLY
RIGHT HAND SIDE (CONTINUED)
STEP 4.
NOTCHED CORNERS TO
BOTTOM OF SHEET
Absco Industries
Aviary Model: A30231GK
SNAP
154L
181
NOTE: THIS EDGE
ONLY FOLDED AT 90
DEGREES.
LAY THESE SECTIONS OVER THE
PANEL AS SHOWN, LOCKING
THE SHEET INTO THE
BOTTOM CHANNEL.
SNAP
181
MOVE THE TOP
INFILL CHANNEL
(181) INTO POSITION.
D
D
D
D
D
D
D
D
ABSCO INDUSTRIES ASSEMBLY INSTRUCTION MANUAL AVIARY MODEL: A30231GK 06-02-2018 PAGE 18
FRONT PANEL ASSEMBLY
STEP 1.
PARTS REQUIRED:
2) CHANNELS (PART 160)
7) JAMBS (PART 191)
JOIN TWO JAMBS TOGETHER
AT PRE-PUNCHED LOCATIONS
AS SHOWN TO FORM TWO
DOUBLE JAMB SECTIONS.
160
191
Absco Industries
Aviary Model: A30231GK
191
191
160
191
191
STEP 2.
JOIN ALL SECTIONS TOGETHER, LINING UP
EACH JAMB WITH PRE-PUNCHED HOLES
LOCATED IN BOTH CHANNEL SECTIONS.
8mm
ABSCO INDUSTRIES ASSEMBLY INSTRUCTION MANUAL AVIARY MODEL: A30231GK 06-02-2018 PAGE 19
Absco Industries
Aviary Model: A30231GK
FRONT PANEL ASSEMBLY (CONTINUED)
SNAP i
STEP 3.
181
LOCK THE CHANNEL ON TO THE
SHEET AS SHOWN. THE CHANNEL
WILL FINISH 30mm IN FROM
EACH SIDE OF THE SHEET.
181
SNAP i
154
SNAP i
181
154
154R
THIS EDGE ONLY
FOLDED AT 90
DEGREES.
STEP 4.
LAY THESE SECTIONS, ONE AT A TIME,
OVER THE FRAME AS SHOWN, LOCKING
THE SHEETS INTO THE BOTTOM
CHANNEL.
D
D
D
D
D
D
192
STEP 6.
MOVE THE FIVE INFILL CHANNELS
INTO POSITION AND SCREW TO THE
TOP/BOTTOM CHANNELS WITH TWO
SCREWS EACH.
D
D
SNAP i
D
D
D
SNAP i
D
SNAP i
STEP 5.
MOVE THE DOOR HINGE
JAMB (PART 192) INTO
POSITION, LOCATING IT
"OVER THE TOP" OF THE
SHEET (154R) AND
SECURING IT TO THE
OTHER JAMB (191). (THE
SCREWS SECURING THE
EXISTING JAMB (191) WILL
HAVE TO BE REMOVED
AND THEN REPLACED)
181
D
D
D
181 D
D
181
D D
181
D
181
ABSCO INDUSTRIES ASSEMBLY INSTRUCTION MANUAL AVIARY MODEL: A30231GK 06-02-2018 PAGE 20
THIS EDGE ONLY
Absco Industries
Aviary Model: A30231GK
FRONT PANEL ASSEMBLY (CONTINUED)
STEP 7.
LAY THE DOOR PANEL IN THE
OPEN POSITION ON THE FRAME
AS SHOWN. USING THE SMALL
FLANGE POP RIVETS,
SECURE THE DOOR
TO THE DOOR
HINGE JAMB.
181
D
195
STEP 8.
FOR THE MIDRAIL ABOVE THE DOOR,
JOIN THE JAMB (195) TO THE
CHANNEL (181) AS SHOWN.
FIT THE MIDRAIL PARALLEL ABOVE THE
DOOR, TO THE SIDE JAMBS WITH
SCREWS FROM THE UNDERNEATH SIDE.
ABSCO INDUSTRIES ASSEMBLY INSTRUCTION MANUAL AVIARY MODEL: A30231GK 06-02-2018 PAGE 21
WALL PANEL ASSEMBLY
Absco Industries
Aviary Model: A30231GK
SIDE WALL PANEL CHANNELS FIT
INTO THE NOTCHED FRONT AND
REAR WALL PANEL CHANNELS
SCREW THE FRONT FRAME CORNER
JAMBS INTO THE PRE-PUNCHED
HOLES OF THE SIDE WALL CORNER
MULLIONS.
ABSCO INDUSTRIES
LAP THESE CORNER
SHEETS, DRILL AND
SCREW TOGETHER.
ASSEMBLY INSTRUCTION MANUAL AVIARY MODEL: A30231GK 06-02-2018 PAGE 22
Absco Industries
Aviary Model: A30231GK
JOIN THE GABLES (16L + 16R) AND
MOVE INTO POSITION AS SHOWN.
DRILL AND SCREW THE GABLES
INTO THE TOP CHANNELS AS
SHOWN.
16R
16L
16L
16R
ATTACHING RIDGE
BEAM TO ROOF PANEL
97B
CHANNEL TYPE
78B THIS END
CHANNEL TYPE
81C THIS END
ABSCO INDUSTRIES ASSEMBLY INSTRUCTION MANUAL AVIARY MODEL: A30231GK 06-02-2018 PAGE 23
Absco Industries
Aviary Model: A30231GK
ROOF CONSTRUCTION
THE ROOF PANELS OVERHANG THE FRONT AND SIDE WALLS BY 37mm, BUT
DO NOT OVERHANG PAST THE REAR WALL.
INSIDE VIEW
SECURE THE RIDGE BEAM TO THE
GABLE SECTIONS WITH TWO SCREWS
AT EACH END. THE RIDGE BEAM
AND ROOF PANEL WILL PROTRUDE
37mm PAST THE FRONT GABLE,
AND WILL FINISH JUST OVER THE
OUTSIDE FACE OF THE REAR GABLES.
SECURE RIDGE BEAM TO
GABLE SECTIONS WITH
TWO SCREWS AT EACH
END. SECURE EACH ROOF
PANEL WITH ONE SCREW
IN EACH CORNER ONLY
AT THIS STAGE
THEN SECURE EACH ROOF PANEL
WITH ONE SCREW IN EACH CORNER
ONLY AT THIS STAGE AS SHOWN
BELOW.
INSIDE VIEW
ABSCO INDUSTRIES
13A
AFTER ATTACHING BOTH ROOF
PANELS TO WALLS AS SHOWN
ABOVE, FIT ONE REGENT BRACE
TO THE RIDGE BEAM AND FRONT
WALL AS SHOWN. YOU WILL HAVE
TO REMOVE AND REPLACE
EXISTING SCREWS AT FIXING
LOCATIONS. REPEAT THIS
PROCEDURE FOR THE REAR
WALL REGENT BRACE
ASSEMBLY INSTRUCTION MANUAL AVIARY MODEL: A30231GK 06-02-2018 PAGE 24
Absco Industries
Aviary Model: A30231GK
FINAL CONSTRUCTION
AS THERE IS NO ROOF
OVERHANG OVER THE REAR
WALL, DRILL THROUGH THE
ROOF LIP FLASHING INTO
THE GABLE SECTIONS AND
SECURE WITH POP RIVETS.
THIS SHOULD BE DONE AFTER THE
REST OF THE ROOF HAS BEEN
SECURED TO THE OTHER WALLS.
VIEW OF
REAR WALL
BEND THE TOP AND BOTTOM
FLANGES AS SHOWN, THEN
HOOK THE BOTTOM FLANGES
UNDER THE ROOF LIP
FLASHINGS AND SCREW THE
TOP FLANGES AS SHOWN
FOR BOTH GABLE CAPS
14A
ANCHORING OF SHED
LOCATION OF 12
CONCRETE ANCHORS
BOLT & NUT
STEEL
ANGLE
WALL
SHEET
- EACH ANCHOR CONSISTS OF ONE NUT, BOLT,
DYNABOLT AND STEEL ANGLE
- DRILL A 10mm HOLE INTO THE WALL SHEET
- DRILL A 10mm HOLE INTO THE CONCRETE
ABSCO INDUSTRIES
SLAB
ASSEMBLY INSTRUCTION MANUAL AVIARY MODEL: A30231GK
DYNABOLT
06-02-2018 PAGE 25
FITTING OF WIRE MESH
ALL MESH SHEETS ARE FITTED TO THE
INSIDE OF THE AVIARY
WARNING
IT IS RECOMMENDED THAT NEW
GALVINESED MESH SHOULD BE
WEATHERED FOR TWO (2) MONTHS
OR SCRUBBED WITH A MILD ACIDIC
SOLUTION SUCH AS VINEGAR, THEN
RINSED WITH WATER BEFORE
BEING USED IN BIRD HOUSING
APPLIANCES.
Absco Industries
Aviary Model: A30231GK
INSIDE VIEW
OF AVIARY
ABSCO INDUSTRIES
THE MESH SHEETS ARE FIXED TO
FRAMEWORK USING THE LARGE FLANGE
RIVETS SUPPLIED.
WORKING FROM INSIDE THE AVIARY,
LOCATE THE FIRST MESH SHEET OVER
THE FRAMEWORK. DRILL 3mm HOLES
AND FASTEN WITH RIVETS TO THE
FRAMEWORK AT 150mm CENTRES.
IT IS IMPORTANT TO CONTINUALLY
STRETCH THE MESH TO ENSURE A
SMOOTH TIGHT FINISH.
replacement or refund for a major failure and for compensation for any other foreseeable loss or damage. You are also entitled
LOCATE RIVETS AT THE INSIDE
INTERSECTION OF THE WIRE TO
FACILITATE TIGHTENING OF THE MESH
AS SHOWN.
three business days to advise you of the assessment outcome of the claim, which may include your expenses incurred in making
ANY EXPOSED RAW ENDS OF WIRE
CAN BE FOLDED INTO THE HOLLOWS
OF THE FRAMEWORK USING A SMALL
PAIR OF PLIERS OR TRIMMED BACK
WITH TIN SNIPS.
ASSEMBLY INSTRUCTION MANUAL AVIARY MODEL: A30231GK 06-02-2018 PAGE 26
Absco Industries
Aviary Model: A30231GK
AUSTRALIA PRODUCT WARRANTY AGAINST DEFECTS
Congratulations on your purchase of an ABSCO SHED
ABSCO SHEDS, including garden sheds, garden beds, aviaries, storage units, garages, awnings and carports are made using high quality Australian made steel.
We are pleased to advise we warrant that the steel coating will not rust, crack, flake peel or blister for 30 years from date of purchase, when installed within Australia.
This warranty does not apply to surface deterioration of panels caused by 'Swarf” (Tiny particles of steel debris left from cutting, grinding or drilling operations) that has not been removed after building construction, or as a result of contact with damp soil, chemicals, fertilisers or other corrosive substances.
This warranty covers any Absco product used for normal domestic use and installed in accordance with the installation instructions. The warranty does NOT cover Damage caused by storms, wind, rain snow or poor foundations.
This warranty does NOT cover ABSCO products installed in severe coastal, industrial or other highly corrosive environments. The warranty does not cover fasteners (screws, nuts, bolts, rivets, hasps or sliding padbolts).
The warranty is limited to replacement and delivery of components and does not include any labour or installation costs. The benefits given by the warranty are in addition to your other rights and remedies under a law in relation to the goods or services to which the warranty relates.
The warranty applies to the exclusion of all other representations, guarantees or warranties express or implied, our goods come with guarantees that cannot be excluded under the Australian consumer law and is not transferable. You are entitled to a replacement or refund for a major failure and for compensation for any other foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of an acceptable quality and the failure does not amount to a major failure. For further information go to http://www.consumerlaw.gov.au
.
Please retain a proof of purchase (sales docket or invoice) or register your warranty within 30 days of purchase here: www.absco.com.au/register_warranty.php
In the unlikely event a warranty claim is made, it must be supported by photographic evidence and details of the defect, including component part numbers, together with proof of purchase documentation (or on-line registration of purchase) and forwarded to the address below. Upon receipt of the warranty claim, the Customer Service Manager will contact you within three business days to advise you of the assessment outcome of the claim, which may include your expenses incurred in making the claim.
THE CUSTOMER SERVICE MANAGER, ABSCO INDUSTRIES, PO BOX 119 ACACIA RIDGE QLD AUSTRALIA 4110
PHONE: 1800 029701 FAX: 07-33441191 EMAIL: [email protected]
Issued 01 January 2013
ABSCO INDUSTRIES ASSEMBLY INSTRUCTION MANUAL AVIARY MODEL: A30231GK 06-02-2018 PAGE 27
This warranty does not apply to surface deterioration of panels caused by 'Swarf” (Tiny particles of steel debris left from cutting, replacement or refund for a major failure and for compensation for any other foreseeable loss or damage. You are also entitled
Absco Industries
Aviary Model: A30231GK
ABSCO SHEDS - STORAGE GUIDELINES
ABSCO SHEDS include garden sheds, garden beds, storage units, aviaries, garages, awnings and carports.
ABSCO SHEDS are designed to be weatherproof for normal weather conditions. In the event of extreme weather conditions such as heavy rain, combined with high wind gusts, the ridge capping, sheeting joins, screw fixings etc., may exhibit minor deformations which may allow some water entry. These areas should be checked regularly to ensure that maximum strength and protection is maintained.
Other weather conditions such as extreme heat and extreme cold, moist or dry air can influence the effects of concrete floor moisture and/or condensation on the underside of the roof sheets.
ABSCO SHEDS and storage units are primarily used for storage of garden equipment such as lawnmowers, wheelbarrows, garden tools etc. Storage items that might be adversely affected by any of the above conditions may require additional protection such as being sealed or covered by plastic sheets and/or stacked above the concrete floor on timber slats.
Waterproof sealants may be used to offer further protection where required around joins and screw fixings, as can rubber door seals and other products which are available from most hardware outlets.
Placement of waterproof sealants (silicone) between the base of the shed and concrete slab is not recommended, as this process can have a reverse effect, preventing excess water from escaping, resulting with water accumulating and being trapped inside the shed.
Absco accepts no responsibility for water entry, floor moisture, condensation or the condition of the Contents inside your Absco steel building arising from any of the pre-mentioned weather conditions.
three business days to advise you of the assessment outcome of the claim, which may include your expenses incurred in making
ABSCO INDUSTRIES ASSEMBLY INSTRUCTION MANUAL AVIARY MODEL: A30231GK 06-02-2018 PAGE 28
advertisement
Key Features
- Pre-assembled parts for easy installation
- Durable steel construction
- Ample storage space
- Aviary-style design with mesh walls
- Weather-resistant and corrosion-resistant materials
- Designed for low maintenance and upkeep
Related manuals
Frequently Answers and Questions
What are the dimensions of the shed?
What materials are used in the construction of the shed?
Is the shed difficult to assemble?
Is the shed weather-resistant?
advertisement