NI Combustion Analysis System Software for LabVIEW User Manual

Add to my manuals
196 Pages

advertisement

NI Combustion Analysis System Software for LabVIEW User Manual | Manualzz

NI Combustion Analysis System Software for LabVIEW

User's Manual

NI Combustion Analysis System Software for LabVIEW™

User's Manual

Web : http://www.ni.com/powertrain-controls , E-mail : [email protected]

© National Instruments. All rights reserved. 1

NI Combustion Analysis System Software for LabVIEW

User's Manual

Table of Contents

1. Product Introduction ...................................................................................................................................5

1.1 Features By License Version .............................................................................................................6

1.2 Data Flow .........................................................................................................................................10

2. Getting Started .........................................................................................................................................11

2.1 Recommended System Requirements ............................................................................................12

2.1.1 Supported C Series Modules ..................................................................................................15

2.2 Hardware Configuration ...................................................................................................................16

2.2.1 Development Version Hardware Setup ...................................................................................17

2.2.2 Deployment Version Hardware Setup .....................................................................................19

2.3 Software Configuration .....................................................................................................................23

2.3.1 Activating Your Software .........................................................................................................24

2.3.2 MAX Hardware Configuration .................................................................................................26

2.2.2.1 Development Version MAX Hardware Configuration .....................................................27

2.2.2.2 Deployment Version MAX Hardware Configuration .......................................................29

2.3.3 Development Version Example Project and System Integration .............................................30

2.4 Performance .....................................................................................................................................32

2.4.1 Development Version Performance Overview ........................................................................33

2.4.1.1 S Series Hardware .........................................................................................................34

2.4.1.2 HDD ................................................................................................................................35

2.4.2 Deployment Version Performance Overview ..........................................................................36

2.4.2.1 cDAQ Hardware .............................................................................................................37

2.4.2.2 NI cDAQ-1939 Benchmark .............................................................................................38

3. NI CAS Software Interface .......................................................................................................................39

3.1 Offline ...............................................................................................................................................41

3.1.1 General Setup .........................................................................................................................42

3.1.1.1 Project Setup ..................................................................................................................43

3.1.1.2 Engine Geometry Setup .................................................................................................44

3.1.1.3 Encoder Setup ................................................................................................................46

3.1.1.4 Calculations ....................................................................................................................48

3.1.1.5 Next-Cycle Calculations .................................................................................................49

3.1.1.6 System Optimization ......................................................................................................50

3.1.2 IO Hardware Setup .................................................................................................................51

3.1.2.1 Sample Rates Setup ......................................................................................................52

3.1.2.2 Sync Analog Channels Setup ........................................................................................53

3.1.2.3 Sync Digital Channels Setup .........................................................................................55

3.1.2.4 Async Analog Channels Setup ......................................................................................56

3.1.2.5 Async Digital Channels Setup ........................................................................................58

3.1.2.6 Medium Speed Channels Setup ....................................................................................59

3.1.2.7 FPGA Stream Setup ......................................................................................................61

3.1.2.8 Analog Output Channels Setup .....................................................................................62

3.2 Online ...............................................................................................................................................63

3.2.1 Settings ....................................................................................................................................64

3.2.1.1 Motoring and TDC Offset Settings .................................................................................65

3.2.1.2 Async Conversion Settings ............................................................................................67

3.2.1.3 Pegging Settings ............................................................................................................68

© National Instruments. All rights reserved. 2

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.2.1.4 Filter Settings .................................................................................................................69

3.2.1.5 Pressure Metrics Settings ..............................................................................................70

3.2.1.6 Unit Conversions Settings ..............................................................................................72

3.2.1.7 Temperature Settings .....................................................................................................73

3.2.1.8 Heat Release Settings ...................................................................................................74

3.2.1.9 Knock Settings ...............................................................................................................76

3.2.1.10 Cam Settings ................................................................................................................80

3.2.1.11 Injection Settings ..........................................................................................................81

3.2.1.12 Spark Settings ..............................................................................................................82

3.2.1.13 Misfire Settings .............................................................................................................83

3.2.1.14 Simulation Settings .......................................................................................................84

3.2.2 File Save .................................................................................................................................86

3.2.2.1 Raw File Save ................................................................................................................87

3.2.2.2 Summary File Save ........................................................................................................89

3.2.3 Status .......................................................................................................................................91

3.2.3.1 Engine .............................................................................................................................92

3.2.3.2 Resources .......................................................................................................................93

3.2.3.3 EPT .................................................................................................................................94

3.2.3.4 Execution ........................................................................................................................95

3.2.3.5 Buffer ..............................................................................................................................96

3.2.3.6 Loop ................................................................................................................................98

3.2.3.7 Error ................................................................................................................................99

3.3 Results ............................................................................................................................................100

3.3.1 X-Axis ....................................................................................................................................101

3.3.2 Plots .......................................................................................................................................102

3.3.3 Tables ....................................................................................................................................108

3.3.4 Trend Charts ..........................................................................................................................109

4. Processing and Calculations ..................................................................................................................110

4.1 Cylinder Volume .............................................................................................................................111

4.2 Waveform Filters ............................................................................................................................113

4.2.1 Boxcar ....................................................................................................................................114

4.2.2 Rolling N Cycles ....................................................................................................................115

4.2.3 Forward and Reverse IIR ......................................................................................................116

4.2.4 FIR Filter with Rollback .........................................................................................................117

4.3 Cylinder Pressure Pegging ............................................................................................................118

4.3.1 Constant ................................................................................................................................119

4.3.2 Synchronous MAP .................................................................................................................120

4.3.3 Polytropic ...............................................................................................................................121

4.4 Pressure Metrics ............................................................................................................................122

4.4.1 Pressure and Pressure Rise Rate ........................................................................................123

4.4.2 Polytropic Coefficients ...........................................................................................................124

4.4.3 TDC Probe ............................................................................................................................126

4.5 Mean Effective Pressure ................................................................................................................127

4.6 Motoring Pressure ..........................................................................................................................128

4.7 Global Gas Temperature ................................................................................................................129

4.8 Injector ............................................................................................................................................130

© National Instruments. All rights reserved. 3

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.9 Heat Release ..................................................................................................................................137

4.9.1 Heat Release Models ............................................................................................................138

4.9.1.1 Single Zone ..................................................................................................................139

4.9.1.2 Single Zone + Heat Transfer ........................................................................................140

4.9.1.3 Single Zone Dual Transducer ......................................................................................141

4.9.1.4 Single Zone Dual Transducer + Heat Transfer ............................................................142

4.9.1.5 Modified Rassweiler and Withrow ................................................................................143

4.9.1.6 Pressure Ratio ..............................................................................................................144

4.9.2 Heat Transfer Correlations ....................................................................................................145

4.9.2.1 Constant .......................................................................................................................146

4.9.2.2 Woschni 1967 ...............................................................................................................147

4.9.2.3 Woschni 1990 ...............................................................................................................148

4.9.2.4 Hohenberg ....................................................................................................................149

4.9.3 Polytropic Correlation ............................................................................................................150

4.9.3.1 Hayes (SAE860029) .....................................................................................................151

4.9.3.2 Indolene (SAE841359) .................................................................................................152

4.9.3.3 Propane (SAE841359) .................................................................................................153

4.9.3.4 Custom .........................................................................................................................154

4.9.4 Start and End of Combustion ...............................................................................................155

4.10 Combustion Noise ........................................................................................................................157

4.11 Misfire ...........................................................................................................................................158

4.12 Cam ..............................................................................................................................................159

4.13 Synchronous Pump ......................................................................................................................160

4.14 PWM .............................................................................................................................................161

4.15 Knock ............................................................................................................................................162

4.16 Spark ............................................................................................................................................163

4.17 Custom User VIs ..........................................................................................................................167

5. Post Processing .....................................................................................................................................172

5.1 NI CAS Software File Structure .....................................................................................................173

5.2 Summary Files ...............................................................................................................................176

5.3 Raw Files ........................................................................................................................................177

5.4 TDMS Files .....................................................................................................................................179

5.5 Batch Processing ...........................................................................................................................181

6. Troubleshooting ......................................................................................................................................183

7. Abbreviations ..........................................................................................................................................187

8. Additional Support/Feedback .................................................................................................................189

9. Important Information .............................................................................................................................190

9.1 Warranty .........................................................................................................................................191

9.2 Copyright ........................................................................................................................................192

9.3 Trademarks .....................................................................................................................................193

9.4 Patents ............................................................................................................................................194

9.5 Warning Regarding Use of NI Products ........................................................................................195

9.6 Environmental Management ..........................................................................................................196

© National Instruments. All rights reserved. 4

NI Combustion Analysis System Software for LabVIEW

User's Manual

1. Product Introduction

The NI Combustion Analysis System Software for LabVIEW (NI CAS) is a unique LabVIEW plug-in for performing sophisticated in-cylinder combustion analysis and data logging for engine research and development targeted to a wide variety of NI Hardware. When licensed as a toolkit it can be used to develop sophisticated PXI-based combustion analysis applications with real-time feedback control capabilities. Licensed as an executable, it can be deployed to portable, low-cost cDAQ hardware.

NI CAS Software allows streaming of raw data to file continuously, by cycle count, time, or file size. Raw data files are stored in National Instrument's popular TDMS format and include all channel configurations, engine geometry and custom test data to allow complete reconstruction of the test environment at a later date. Cycle-by-cycle summaries of analysis parameters can also be logged to TDMS files for later review. The TDMS file format is an open format allowing these files to be post-processed with a variety of tools, including the NI CAS Software Post-

Processing tools, NI DIAdem, or Microsoft Excel.

License Versions

Development License

The Development License of NI CAS Software enables a LabVIEW toolkit for users to integrate sophisticated combustion analysis and data logging with engine control applications. The toolkit includes many analysis functions, front panel controls, and utilities including data-streaming-to-disk, pre-processing, heat release, pressure metrics, knock analysis, noise analysis, raw data logging, summary data reporting and postprocessing.

The NI CAS Software for Development leverages R Series (FPGA), S Series (simultaneous analog sampling) and M Series (Multiplexed analog sampling) PXI devices from National Instruments to supervise engine position tracking and synchronization of data collection and processing. SCXI hardware can be leveraged for medium-speed data collection which is subsequently aligned with engine-synchronous data.

This software can be targeted to a wide variety of PXI real-time controllers depending on the application performance requirements.

The Development Version of NI CAS Software example application may be used stand-alone or integrated with an engine control application.

Deployment License

The Deployment License enables deployment to low-cost, easy-to-use, portable engine combustion analysis hardware bundles. NI CAS Software for Deployment is a pre-built NI LabVIEW Runtime executable for

Microsoft Windows, targeting cDAQ hardware over USB and Ethernet, or Stand-Alone cDAQ chassis. Over fifty NI C Series I/O modules can be added to any available slot of an NI cDAQ chassis to meet a variety of application needs.

The Deployment Version of NI CAS Software supports three time-bases: high-speed engine-synchronous, high-speed angular-window time domain and medium-speed time domain. The Deployment License includes all of the analysis functions included in the Development Version of NI CAS Software toolkit except for

Next-Cycle control and FPGA based Engine Position Tracking (EPT) functions. Engine synchronous data sampling must take place using optical shaft encoders mounted to the crankshaft.

© National Instruments. All rights reserved. 5

NI Combustion Analysis System Software for LabVIEW

User's Manual

1.1 Features By License Version

License Version

Highlighted Features

• Open source example projects for integration with real-time control applications

Development

X

Deployment

• Next-cycle control capabilities

• FPGA based high speed signal processing

• Low-cost, feature rich, turnkey bundled system

X

X

X

Measurement Configuration and Engine Geometry

• Individual channel scaling features

• Cylinder Assignment

• Gain

• Gain + Offset

• Polynomial

• Table Lookup

License Version

Development

X

Deployment

X

X

X

X

X

• Channels can be assigned to all cylinders as references such as pegging

• Simultaneous engine-synchronous and engine-asynchronous measurements

• Medium Speed Data (Sampled at a fixed frequency ~1kHz or less)

• Thermocouples

• Slow Speed Pressures

• Other

• Supports FPGA Data (Sampled based on FPGA setup, engine synchronous and/or asynchronous)

• Digital outputs for sample clock and active high during logging

• Supports multiple S Series devices for simultaneous sampling of signals in both engine-synchronous (cylinder pressure, etc.) and engineasynchronous (knock, etc.) domains

• Supports 1 M Series device for multiplexed sampling of signals enginesynchronously (cylinder pressure, etc.)

X

X

X

X

X

X

X

X

© National Instruments. All rights reserved. 6

NI Combustion Analysis System Software for LabVIEW

User's Manual

• Supports 1 cDAQ chassis and multiple C Series devices for simultaneous sampling of signals in both engine-synchronous (cylinder pressure, etc.) and engine-asynchronous (knock, etc.) domains

X X

Support for mapping calculated parameters to analog output channels

• Complete set of engine geometry inputs for cylinder volume calculation

• Optionally load volume from file

X

X

X

X

• Online motoring test assists with engine geometry verification

• TDC probe channel configuration and analysis

X

X

X

• Allows online adjustment of TDC index (< +/- 2 CAD)

FPGA Based Engine Position Tracking and Sample Clock Generation

• Use traditional optical encoder setup with advanced triggering options

X

X

X

• Flexible crankshaft encoder signal processing and filtering

• Use of pressure signal for 4-stroke cam phase information

• Use of cam phase signal as half cycle gate for TDC index

X

X

X

X

License Version

Development

X

Deployment

• Use of Engine Position Tracking (EPT) block for extrapolation of lower resolution production trigger wheels for high resolution sampling and control

File Saving

• Supports simultaneous streaming of raw and summary data to TDMS file continuously, by cycle count, time, or file size

• Raw data files include channel configuration, engine geometry, and test data to allow full reconstruction of the test environment in post-processing

• Supports an external hardware trigger for file saving

• Saves all non-NI CAS Software related CalPoints, e.g., engine controls

Development

X

X

X

X

License Version

Deployment

X

X

X

© National Instruments. All rights reserved. 7

Pre-Processing

• Cylinder alignment of data in both engine-synchronous and engineasynchronous domains

• Data scaling to engineering units

• Broad range of signal filtering options

• Cylinder pressure pegging options

• Optional user developed LabVIEW VI

Pressure Metrics

• Peak Pressure and Location

• Polytropic coefficients of compression and expansion

• Maximum Rate of Pressure Rise and Location

• Pressures at IVO and EVC

• Gross IMEP, Pumping MEP (PMEP), Net IMEP

Heat Release Analysis

• Methods include

• Single Zone

• Single Zone Dual Transducer (for pre-chamber engines)

• Single Zone + Heat Transfer

• Single Zone Dual Transducer + Heat Transfer

• Modified Rassweiler and Withrow

• Pressure Ratio

• User developed LabVIEW™ VI

• Locations of Mass Fraction Burned (5%MFB, 25%MFB, 50%MFB,

75%MFB, 90%MFB, Custom)

• Maximum heat release rate and location

• Variety of heat transfer correction methods

NI Combustion Analysis System Software for LabVIEW

User's Manual

License Version

Development

X

Deployment

X

X

X

X

X

X

X

X

X

X

X

X

X

License Version

Development

X

Development

X

X

X

X

Deployment

License Version

X

X

X

X

X

Deployment

X

X

X

X

© National Instruments. All rights reserved. 8

• In-cylinder temperature estimation

Engine Noise and Knock Analysis

• Raw, time-domain-filtered and angle-domain-filtered noise indication

• Bandpass / Rectify / Integrate / Compare (BRIC) algorithm for knock signal processing

• Visual FFT analysis of knock signals for calibration of BRIC

Additional Calculations and Analysis

• Injection parameters of timing, duration and quantity (mg/injection)

• Cycle to cycle injection quantity (mg/cycle)

• Ignition parameters of timing and dwell

• Multi-strike analysis

• Cam phase measurement

• Optional user developed LabVIEW VI

NI Combustion Analysis System Software for LabVIEW

User's Manual

X X

License Version

Development

X

X

X

Deployment

X

X

X

License Version

Development

X

Deployment

X

X

X

X

X

X

X

X

X

X

X

© National Instruments. All rights reserved. 9

NI Combustion Analysis System Software for LabVIEW

User's Manual

1.2 Data Flow

The Development Version of NI CAS Software example project employs the real-time data flow structure shown below with an optional next-cycle control path. In the next-cycle control path, the DAQ alignment is stopped early to allow selected calculations to complete before the subsequent cycle begins. The example application also provides an estimated angle of completion of next-cycle calculations. The Deployment Version of NI CAS Software utilizes a similar data flow structure, however, the data processing takes place within a Microsoft Windows operating system and lacks next-cycle calculation capability.

© National Instruments. All rights reserved. 10

2. Getting Started

NI Combustion Analysis System Software for LabVIEW

User's Manual

© National Instruments. All rights reserved. 11

NI Combustion Analysis System Software for LabVIEW

User's Manual

2.1 Recommended System Requirements

Note: System requirements will vary based on many factors including:

• Number of measurements

• Maximum sample rate

• Enabled real-time calculations

Development Version of NI CAS Software

Target System

Recommended Real-time System

PXI Chassis:

Controller:

FPGA:

C Series Hardware:

NI PXI-1050 PXI Chassis With Integrated SCXI--8 PXI/4 SCXI

Slots

NI PXI-8119 RT 2.3 GHz Quad-Core PXI Controller With

LabVIEW Real-Time

80GB or Greater, 2.5 in SATA SSD

NI PXI-7853R R Series Multifunction RIO With Virtex-5 LX85

FPGA

• NI 9151 R Series Expansion Chassis for C Series I/O

• NI 9411 6-Channel, 500ns, ±5 to 24 V Digital Input Module

• NI SHC68-68-RDIO Digital Cable for R Series

S Series DAQ:

M Series DAQ

SCXI Modules:

2 to 4 NI PXI-6123 16-Bit, 500 kS/s/ch, Simultaneous Sampling

Multifunction DAQ

NI PXI-6251 16-Bit, 1 MS/s (Multichannel), 1.25MS/s (1-

Channel), 16 Analog Inputs

• 1 or 2 NI SCXI-1102 32-Channel Thermocouple/Voltage

Input Module

• 1 or 2 NI SCXI-1102B 32-Channel Amplifier Module;

200Hz Bandwidth

DAQ Accessories:

• 2 to 4 NI BNC-2090A Shielded Rack-Mount BNC

Connector Block

• 2 to 4 SH68-68-EP (for S Series modules)

• 1 or 2 TC-2095 (for NI SCXI-1102)

• 1 or 2 BNC-2095 (for NI SCXI-1102B)

• 2 to 4 SH96-96 (for SCXI modules)

Host System

Recommended System

CPU:

OS:

1.6 GHz Multi-Core or faster

Microsoft Windows 7/8

© National Instruments. All rights reserved. 12

RAM:

Hard Drive:

Software:

NI Combustion Analysis System Software for LabVIEW

User's Manual

4 GB or more

10 GB or more free space

• NI LabVIEW Professional Development System

• NI LabVIEW Real-Time Module

• NI LabVIEW FPGA Module

• NI-DAQmx

• NI-RIO

• NI LabVIEW FPGA Module Xilinx Tools

• NI Software Calibration Management Toolkit for LabVIEW

Display resolution: ≥1920x1080

© National Instruments. All rights reserved. 13

NI Combustion Analysis System Software for LabVIEW

User's Manual

Deployment Version of NI CAS Software

Target System

Recommended cDAQ System cDAQ Chassis: • NI cDAQ-9139 NI CompactDAQ Stand-Alone Chassis,

Core i7 1.33 GHz, 8-slot

• NI cDAQ-9174 NI CompactDAQ 4-Slot USB Chassis

• NI cDAQ-9178 NI CompactDAQ 8-Slot USB Chassis

• NI cDAQ-9184 NI CompactDAQ 4-Slot Ethernet Chassis

• NI cDAQ-9188 NI CompactDAQ 8-Slot Ethernet Chassis

C Series Modules:

See Supported C Series Modules

Host System for USB and Ethernet cDAQ Targets

Recommended System

CPU:

OS:

1.6 GHz Multi-core or faster

Microsoft Windows 7/8

RAM:

Hard Drive:

USB:

Software:

4 GB or more

10 GB or more free space

2.0 (for USB devices)

• LabVIEW Runtime Engine

• NI-DAQmx

• NI Software Calibration Management Toolkit for LabVIEW

Display resolution: ≥1920x1080

© National Instruments. All rights reserved. 14

NI Combustion Analysis System Software for LabVIEW

User's Manual

2.1.1 Supported C Series Modules

Data Type

Encoder

High-speed Enginesynchronous

Supported Modules

NI 9401 8 Ch, 5 V/TTL High-Speed Bidirectional Digital I/O Module

NI 9411 6-Channel, 500 ns, ±5 to 24 V Digital Input Module

(Recommended)

NI 9215 4-Channel, 100 kS/s/ch, 16-bit, ±10 V Analog Input Module

NI 9220* 16-Channel, 100 kS/s/ch, 16-Bit, ±10 V Analog Input Module

NI 9222* 4-Channel, 500 kS/s, 16-Bit Simultaneous Analog Input

Module (Recommended)

NI 9223* 4-Channel, 1 MS/s, 16-Bit Simultaneous Analog Input Module

High-speed Engineasynchronous

Medium Speed:

NI 9215 4-Channel, 100 kS/s/ch, 16-bit, ±10 V Analog Input Module

NI 9220* 16-Channel, 100 kS/s/ch, 16-Bit, ±10 V Analog Input Module

NI 9222* 4-Channel, 500 kS/s, 16-Bit Simultaneous Analog Input

Module (Recommended)

NI 9223* 4-Channel, 1 MS/s, 16-Bit Simultaneous Analog Input Module

NI 9201 8-Ch, ±10 V, 500 kS/s, 12-Bit Analog Input Module

NI 9203 8-Ch ±20 mA, 200 kS/s, 16-Bit Analog Current Input Module

(Recommended)

NI 9205 32-Ch ±200 mV to ±10 V, 16-Bit, 250 kS/s Analog Input Module

(Recommended)

NI 9211 4-Channel, 14 S/s, 24-Bit, ±80 mV Thermocouple Input Module

NI 9213 16-Channel Thermocouple Input Module (Recommended)

NI 9215 4-Channel, 100 kS/s/ch, 16-bit, ±10 V Analog Input Module

NI 9220* 16-Channel, 100 kS/s/ch, 16-Bit, ±10 V Analog Input Module

NI 9222* 4-Channel, 500 kS/s, 16-Bit Simultaneous Analog Input

Module

NI 9223* 4-Channel, 1 MS/s, 16-Bit Simultaneous Analog Input Module

NI 9401 8 Ch, 5 V/TTL High-Speed Bidirectional Digital I/O Module

NI 9402 4 Ch LVTTL High-Speed Digital I/O Module

NI 9411 6-Channel, 500 ns, ±5 to 24 V Digital Input Module

Output: • NI 9263 4-Channel, 100 kS/s, 16-bit, ±10 V, Analog Output Module

NI 9264 16-Channel Analog Output Module

NI 9265 4-Channel, 100 kS/s, 16-Bit, 0 to 20 mA Analog Output Module

(Recommended)

NI 9269 Channel-to-Channel Isolated 10 V Analog Output Module

(Recommended)

*If BNC connectivity is required, we recommend using L-com Item # BC55 or L-com Item # BC25 .

© National Instruments. All rights reserved. 15

NI Combustion Analysis System Software for LabVIEW

User's Manual

2.2 Hardware Configuration

© National Instruments. All rights reserved. 16

NI Combustion Analysis System Software for LabVIEW

User's Manual

2.2.1 Development Version Hardware Setup

PXI Chassis Configuration

The PXI chassis should contain an NI PXI-785xR FPGA and one or more NI PXI-6123 S Series devices. The R

Series devices must be inserted into PXI slot number 2 (adjacent to the controller). The FPGA is used to track the engine position and generate sample clocks. The FPGA should connect to a NI 9151 expansion chassis with a NI

9411 DI module for the encoder inputs.

S Series Accessory Configuration

The NI PXI-6123 S Series devices requires four wiring jumpers applied at each NI BNC-2090A accessory as shown in the diagrams below. For the NI BNC-2090A accessory, NI recommends that 3" of 20AWG wire with ends stripped by 0.25" should be used for each jumper.

NI PXI-6123 Accessory Terminals

Source

PFI 03

PFI 04

PFI 08

PFI 09

Optional User Input

Destination

P0 0

P0 1

P0 2

P0 3

P0 4

Optional User Input

Optional User Input

P0 5

P0 6

Optional User Input P0 7

NI 9411 Digital Input Module Connections

When using the NI 9411 digital input module, the crankshaft optical encoder may be optionally powered by the

and COM module. If the encoder is powered from the module, power (5 to 30 VDC) must be supplied to the V sup screw terminals of the module. V sup

is internally reduced to +5V and available from the DSUB connector. The encoder should be connected to the NI 9411 module according to the table below. Please note that the NI 9411 module inputs are optionally single-ended or differential pairs. Some optical encoders provide complimentary/ differential signal outputs which enable greater noise immunity when connected with differential digital inputs. The table below shows the connections to be made for single-ended or differential operation. If single-ended operation is required, then the “b” pin of each input should be left unconnected. Shielded cabling is recommended.

Encoder Signal NI 9411 DB15 Connector Pin

Encoder +5V (optional)

Encoder Ground (optional)

Encoder Z (required)

Encoder Z Compliment (optional)

Externally Supplied or NI 9411 Pin 4 (+5Vout)

Externally Supplied or NI 9411 Pin 12 (COM)

NI 9411 Pin 2 (P0.1+/PFI 1 (DI 1a))

NI 9411 Pin 10 (P0.1-/PFI 1 (DI 1b))

© National Instruments. All rights reserved. 17

NI Combustion Analysis System Software for LabVIEW

User's Manual

Encoder A (required)

Encoder A Compliment (optional)

NI 9411 Pin 1 (P0.0+/PFI 0 (DI 0a))

NI 9411 Pin 9 (P0.0-/PFI 0 (DI 0b))

Encoder B (optional) NI 9411 Pin 3 (P0.2+/PFI 2 (DI 2a))

Encoder B Compliment (optional) NI 9411 Pin 11 (P0.2-/PFI 2 (DI 2b))

Expected Encoder Signals

The Deployment Version of NI CAS Software allows for a variety of encoders and triggering options by using the

Engine Position Tracking (EPT) FPGA cores to synchronize the DAQ sampling. The FPGA block accepts only the encoder pattern. The encoder pattern consists of evenly spaced A and B pulses combined with a once per revolution

Z pulse.

An additional signal can optionally be used to determine the phase of a 4-stroke engine. This can be any signal that has a unique pattern for the complete engine cycle, e.g., a cam pattern, cylinder pressure, spark, injector or similar.

The Development Version of NI CAS Software also has the ability to extrapolate low resolution encoder signals to increase the sample resolution greater than the encoder resolution. Similarly, the encoder signal can be divided to reduce the sample resolution.

© National Instruments. All rights reserved. 18

NI Combustion Analysis System Software for LabVIEW

User's Manual

2.2.2 Deployment Version Hardware Setup cDAQ Chassis Configuration

NI cDAQ-9139 (Stand-alone)

The NI cDAQ-9139 must utilize a NI 9411 (recommended), NI 9401, or a NI 9402 digital input module for encoder inputs. The Deployment Version of NI CAS Software is installed directly on the integrated NI cDAQ-9139 controller

Microsoft Windows OS. The user interface can be displayed on a monitor attached to the cDAQ or via remote desktop over the network.

NI cDAQ-9174 / NI cDAQ-9178 (USB)

The NI cDAQ-9174 must have a NI 9411 (recommended), NI 9401, or a NI 9402 digital input module for encoder inputs. The NI cDAQ-9178 may use the chassis trigger lines, a NI 9411 (recommended), a NI 9401, or a NI 9402 digital input module.

NI cDAQ-9184 / NI cDAQ-9188 (Ethernet)

The NI cDAQ-9184 must have a NI 9411 (recommended), NI 9401, or a NI 9402 digital input module for encoder inputs. The NI cDAQ-9188 may use the chassis trigger lines, a NI 9411 (recommended), a NI 9402, or a NI 9411 digital input module.

© National Instruments. All rights reserved. 19

NI Combustion Analysis System Software for LabVIEW

User's Manual

C Series Hardware

The Deployment Version of NI CAS Software requires a 4-slot (or greater) USB, Ethernet, or stand-alone cDAQ chassis, an NI 9411 digital input module, and one or more analog input modules. The compatible C Series I/O

modules are listed in the Support C Series Modules page.

Connect and install the cDAQ hardware according the recommendations found at: http://www.ni.com/gettingstarted

Encoder Connections

NI 9411 Differential Digital Input Module (recommended)

For optimum signal integrity, NI recommends using the NI 9411 Differential Digital Input Module connected to an optical encoder supporting complimentary outputs.

When using the NI 9411 digital input module, the crankshaft optical encoder may be optionally powered by the module. If the encoder is powered from the module, power (5 to 30 VDC) must be supplied to the V sup

and COM

is internally reduced to +5V and available from the DSUB connector. The screw terminals of the module. V sup encoder should be connected to the NI 9411 module according to the table below. Please note that the NI 9411 module inputs are optionally single-ended or differential pairs. Some optical encoders provide complimentary/ differential signal outputs which enable greater noise immunity when connected with differential digital inputs. The table below shows the connections to be made for single-ended or differential operation. If single-ended operation is required, then the “b” pin of each input should be left unconnected. Shielded cabling is recommended.

Encoder Signal NI 9411 DB15 Connector Pin

Encoder +5V (optional)

Encoder Ground (optional)

Externally Supplied or NI 9411 Pin 4 (+5Vout)

Externally Supplied or NI 9411 Pin 12 (COM)

Encoder Z (required)

Encoder Z Compliment

(optional)

Encoder A (required)

Encoder A Compliment

(optional)

NI 9411 Pin 2 (P0.1+/PFI 1 (DI 1a))

NI 9411 Pin 10 (P0.1-/PFI 1 (DI 1b))

NI 9411 Pin 1 (P0.0+/PFI 0 (DI 0a))

NI 9411 Pin 9 (P0.0-/PFI 0 (DI 0b))

© National Instruments. All rights reserved. 20

NI Combustion Analysis System Software for LabVIEW

User's Manual

NI 9401 Digital Input Module

When using the NI 9401 digital I/O module, the crankshaft optical encoder must be powered externally and a ground reference from the encoder must be connected to a COM pin of the NI 9401 module. The encoder should be connected to the NI-9401 module according to the table below. Shielded cabling is recommended.

Crankshaft optical encoder connections to the NI 9401 module

Encoder Signal NI 9401 DB25 Connector Pin

Encoder Ground (required) NI 9401 Pin 1 (COM)

Encoder Z (required) NI 9401 Pin 16 (P0.1/PFI 1)

Encoder A (required) NI 9401 Pin 14 (P0.0/PFI 0)

NI 9402 Digital Input Module

When using the NI 9402 digital I/O module, the crankshaft optical encoder must be powered externally. The NI

9402 should be used when BNC connectors are desired. The encoder should be connected to the NI 9402 module according to the table below.

Crankshaft optical encoder connections to the NI 9402 module

Encoder Signal NI 9402 BNC

Encoder Z (required) NI 9402 BNC2 (P0.1/PFI 1)

Encoder A (required) NI 9402 BNC1 (P0.0/PFI 0)

NI cDAQ-9178 Chassis

When using the NI cDAQ-9178 chassis external triggers, the crankshaft optical encoder must be externally powered.

The encoder should be connected to the NI cDAQ-9178 chassis according to the table below. Shielded cabling is recommended.

Crankshaft optical encoder connections to the cDAQ-9178 chassis

Encoder Signal NI cDAQ-9178 Chassis BNC Connector

Encoder Z (required) cDAQ-9178 Trig 1

Encoder A (required) cDAQ-9178 Trig 0

Analog Input Module Connections

The analog instrumentation signals should be connected to the NI 9215, NI 9222, or NI 9223 analog inputs. The

BNC version of the NI 9215 is recommended for ease of connection. Shielded BNC cables are recommended.

Configuring cDAQ Chassis with NI Measurement and Automation Explorer

NI Measurements and Automation Explorer (MAX) should be used to discover or change the name of the DAQ device and its physical channels. The names of the device and physical channels will be used on the measurement configuration tab of the user interface.

© National Instruments. All rights reserved. 21

NI Combustion Analysis System Software for LabVIEW

User's Manual

Ethernet cDAQ devices must be registered and reserved in MAX before they can be used with the Deployment

Version of NI CAS Software. To add a cDAQ chassis to a system, right click on "My System > Devices and Interfaces

> Network Devices" and select "Find Network NI-DAQmx Device". To reserve the cDAQ chassis on a system, right click on the discovered cDAQ chassis and select "Reserve Chassis".

When using the DAQ device with the Deployment Version of NI CAS Software, only the terminals described above should be used. In order to take full advantage of certain hardware features, the Deployment Version of NI CAS

Software makes programmatic internal connections. Connecting signals to other terminals or running other programs which interact with the DAQ device may cause unexpected behavior.

© National Instruments. All rights reserved. 22

NI Combustion Analysis System Software for LabVIEW

User's Manual

2.3 Software Configuration

For more information on the NI Combustion Analysis System Software for NI LabVIEW, please visit

http:// www.ni.com/powertrain-controls/

.

To download the NI Combustion Analysis System Software for LabVIEW, visit

http://www.ni.com/info

and enter the Info Code "CASSoftware".

After installing NI CAS Software, it will run for a 7 day full evaluation period. Any time during or after the

evaluation period, NI CAS Software may be activated using the

NI License Manager

found in the start menu.

© National Instruments. All rights reserved. 23

NI Combustion Analysis System Software for LabVIEW

User's Manual

2.3.1 Activating Your Software

Activating Your Software

This section describes how to use the NI Activation Wizard to activate your software.

How Do I Activate My Software?

Use the NI Activation Wizard to obtain an activation code for your software. You can launch the NI Activation Wizard two ways:

• Launch the product and choose to activate your software from the list of options presented.

• Launch NI License Manager by selecting

Start»All Programs»National Instruments»NI License

Manager. Click the Activate button in the toolbar.

Notes

• If your software is a part of a Volume License Agreement (VLA), contact your VLA administrator for installation and activation instructions.

• NI software for Mac OS X and Linux operating systems does not require activation.

What is Activation?

Activation is the process of obtaining an activation code to enable your software to run on your computer. An activation code is an alphanumeric string that verifies the software, version, and computer ID to enable features on your computer. Activation codes are unique and are valid on only one computer.

What is the NI Activation Wizard?

The NI Activation Wizard is a part of NI License Manager that steps you through the process of enabling software to run on your machine.

What Information Do I Need to Activate?

You need your product serial number, user name, and organization. The NI Activation Wizard determines the rest of the information. Certain activation methods may require additional information for delivery. This information is used only to activate your product. Complete disclosure of the National Instruments software licensing information privacy policy is available at ni.com/activate/privacy. If you optionally choose to register your software, your information is protected under the National Instruments privacy policy , available at ni.com/privacy.

How Do I Find My Product Serial Number?

Your serial number uniquely identifies your purchase of NI software. You can find your serial number on the

Certificate of Ownership included in your software kit. If your software kit does not include a Certificate of Ownership, you can find your serial number on the product packing slip or on the shipping label.

If you have installed a previous version using your serial number, you can find the serial number by selecting the

Help»About menu item within the application or by selecting your product within NI License Manager (Start»All

Programs»National Instruments»NI License Manager). You can also contact your local National Instruments branch .

© National Instruments. All rights reserved. 24

NI Combustion Analysis System Software for LabVIEW

User's Manual

What is a Computer ID?

The computer ID contains unique information about your computer. National Instruments requires this information to enable your software. You can find your computer ID through the NI Activation Wizard or by using NI License

Manager, as follows:

1. Launch NI License Manager by selecting

Start»All Programs»National Instruments»NI License

Manager.

2. Click the Display Computer Information button in the toolbar.

For more information about product activation and licensing , refer to ni.com/activate.

How Can I Evaluate NI Software?

You can install and run most NI application software in evaluation mode. This mode lets you use a product with certain limitations, such as reduced functionality or limited execution time. Refer to your product documentation for specific information on the product’s evaluation mode.

Moving Software After Activation

To transfer your software to another computer, install and activate it on the second computer. You are not prohibited from transferring your software from one computer to another and you do not need to contact or inform NI of the transfer. Because activation codes are unique to each computer, you will need a new activation code. Refer to

How

Do I Activate My Software?

to acquire a new activation code and reactivate your software.

Deactivating a Product

To deactivate a product and return the product to the state it was in before you activated it, right- click the product in the NI License Manager tree and select Deactivate. If the product was in evaluation mode before youactivated it, the properties of the evaluation mode may not be restored.

Using Microsoft Windows Guest Accounts

NI License Manager does not support Microsoft Windows Guest accounts. You must log in to a non-Guest account to run licensed NI application software.

© National Instruments. All rights reserved. 25

NI Combustion Analysis System Software for LabVIEW

User's Manual

2.3.2 MAX Hardware Configuration

© National Instruments. All rights reserved. 26

NI Combustion Analysis System Software for LabVIEW

User's Manual

2.2.2.1 Development Version MAX Hardware Configuration

Using NI Measurement and Automation Explorer (MAX), configure the PXI chassis and real-time controller. Set the IP address to a desired static value. Install the current versions of NI LabVIEW Real-Time Module and the

NI-DAQmx Drivers along with any other desired software. Finally, make sure the PXI system controller and PXI chassis are defined correctly in MAX, as shown in figures below MAX can also change the aliases (names) and basic configurations of the DAQ devices if desired.

The user must take note of a few configuration settings in MAX in order to work with NI CAS Software. The DAQ device aliases, as shown in the figures below, are used to identify the physical channels in the NI CAS Software measurement setup. The DAQ device can be renamed by right clicking on the device and selecting the rename option. Finally, the user must confirm that the PXI Trigger Lines are not reserved for other functions in MAX, as shown in the figures below. They are automatically reserved as a part of the channel configuration within the NI CAS

Software.

PXI Chassis Identification configuration in MAX

© National Instruments. All rights reserved. 27

NI Combustion Analysis System Software for LabVIEW

User's Manual

NI-DAQmx device names in MAX

PXI Trigger Reservation options

© National Instruments. All rights reserved. 28

NI Combustion Analysis System Software for LabVIEW

User's Manual

2.2.2.2 Deployment Version MAX Hardware Configuration

The user must take note of a few configuration settings in NI Measurement and Automation Explorer (MAX) in order to work with the NI CAS Software. The DAQ device aliases, as shown below, are used to identify the physical channels in the NI CAS Software measurement setup. The DAQ device can be renamed by right clicking on the device and selecting the rename option.

© National Instruments. All rights reserved. 29

NI Combustion Analysis System Software for LabVIEW

User's Manual

2.3.3 Development Version Example

Project and System Integration

The Development Version of NI CAS Software can be run as a stand alone application using the NI CAS Software example application. The following steps are required to run the NI CAS Software example.

1. Open the CAS example project. From LabVIEW, select Help > Find Examples. Search for "Combustion

Analysis"

2. Update the PXI target IP address for the user's PXI target. Right click on the PXI icon in the project and select

"Properties"

3. Confirm or update the expansion chassis, C Series modules, and FPGA I/O in "CAS FPGA.vi" to match the user's hardware.

4. Open and compile "CAS FPGA.vi" in the FPGA target.

5. Open "CAS Target.vi" in the PXI target.

6. Run "SCM Init" by double clicking on the icon on the block diagram of "CAS Target.vi". It is the right most block diagram item.

7. Run "CAS Target.vi".

8. Launch NI SCM Console and point it to the PXI target IP address, "CAS Host.vi", and "CAS Host.par". The host files are located with the project in the examples folder. For more information on the SCM Console, please see the SCM user's manual.

Integrating Development Version Into An Engine Control Application

The Development Version of NI CAS Software can run as a stand alone application or as part of a larger project. A single PXI chassis can run both an engine controller and combustion analysis. Integrating the two systems into a single platform allows lowered equipment costs in addition to providing closed loop feedback to the engine controller.

The following steps are required to integrate the Development Version of NI CAS Software into an engine control application.

First, open the CAS example project. From LabVIEW, select Help > Find Examples. Search for "CAS".

FPGA

1. Open "CAS FPGA.vi" under the CAS PXI\FPGA target.

2. Copy the single cycle loop from the CAS PXI\FPGA to the engine control FPGA.

3. Copy "CAS Data" and "CAS Encoder Debug" FIFOs from the CAS PXI\FPGA target to the engine control FPGA target.

4. Copy the PXI folder containing TRIG0-7 from the CAS PXI\FPGA target to the engine control FPGA target.

5. Make sure the encoder signals are connected to the appropriate sources.

6. Compile the engine control FPGA VI.

Real-Time

1. Open "CAS Target.vi" under the PXI target.

2. Copy the contents of "CAS Target.vi" into your engine control target VI.

3. Remove the SCM Init VI and FPGA Open Reference function copied from the CAS example.

4. Connect the the SCM Init VI and FPGA Open Reference function from your engine control application to the copied CAS code.

© National Instruments. All rights reserved. 30

Note: The FPGA reference must be set to "Dynamic mode"

NI Combustion Analysis System Software for LabVIEW

User's Manual

© National Instruments. All rights reserved. 31

2.4 Performance

NI Combustion Analysis System Software for LabVIEW

User's Manual

© National Instruments. All rights reserved. 32

NI Combustion Analysis System Software for LabVIEW

User's Manual

2.4.1 Development Version Performance Overview

The performance of the system depends on many factors including:

• PXI Controller Speed, Ram, & OS (Microsoft Windows or Real-Time)

• DAQ Hardware Limitations (Sampling Rate, Response Times)

• Engine Speed

• Cylinder/Measurement Count

• Asynchronous Sampling Rate

• Medium Speed Data (Number of Channels and Sample Rate)

• FPGA Data (Number of Channels and Sample Rate)

• Encoder Resolution

• Calculation Parameters

• HDD Throughput

• User Calculations

© National Instruments. All rights reserved. 33

NI Combustion Analysis System Software for LabVIEW

User's Manual

2.4.1.1 S Series Hardware

One of the key items limiting the maximum engine speed is the DAQ hardware. There are two cases where the

DAQ hardware may limit the maximum engine speed. The first is the case where the DAQ equipment has a large sample rate but the encoder resolution is high. For example, a 500kS/s/ch DAQ device is limited to ~8333RPM with a 3600ppr encoder. The second case is where the DAQ hardware has a small sample rate. For example, a multiplexed sampling device at 1MS/s divided among 16 channels has a 62.5kS/s/ch sampling rate.

The data above was calculated using the following equation:

Where:

MS = Maximum Speed [RPM]

SR = Sample Rate [kS/s/ch]

ER = Encoder Resolution [ppr]

© National Instruments. All rights reserved. 34

NI Combustion Analysis System Software for LabVIEW

User's Manual

2.4.1.2 HDD

Streaming data to the disk requires that the speed of the hard drive is fast enough to keep up with the data waiting to write to it. Disk access is typically between 10MB/s and 70MB/s. However, due to seek times and writing header information, the actual speed at which the system can stream data to disk may be slower. The throughput of a specific HDD is dependent on many factors including the type of hard drive and the system that it is installed in. The

NI CAS Software will buffer data in the RAM if the disk is not fast enough to stream all the data to disk. However, the buffers have limited space and cannot sustain continuous streaming if the disk is not fast enough.

The data above was calculated using the following equation:

Where:

MS = Maximum Speed [RPM]

SR = Sample per Rotation []

DS = Disk Speed [MB/s]

© National Instruments. All rights reserved. 35

NI Combustion Analysis System Software for LabVIEW

User's Manual

2.4.2 Deployment Version Performance Overview

The performance of the system depends on many factors including:

• CPU speed

• RAM size and speed

• Hard drive speed

• Operating system and additional running applications

• DAQ hardware limitations (sampling rate, response times)

• Medium Speed Data (Number of Channels and Sample Rate)

• Engine speed

• Encoder resolution

• Cylinder and measurement channel count

• Calculation configurations

© National Instruments. All rights reserved. 36

NI Combustion Analysis System Software for LabVIEW

User's Manual

2.4.2.1 cDAQ Hardware

The figure below shows the cDAQ hardware limitations. The cDAQ system uses simultaneous sampling device.

Therefore, the DAQ hardware limitations are constant for any number of cylinders.

The following formula can be used to estimate the performance of a simultaneous DAQ hardware device.

Where:

Speed = Maximum Engine Speed [rpm]

MSR = Maximum Sample Rate of DAQ device (kS/s)

ER = Encoder Resolution [ppr]

© National Instruments. All rights reserved. 37

NI Combustion Analysis System Software for LabVIEW

User's Manual

2.4.2.2 NI cDAQ-1939 Benchmark

The NI cDAQ-1939 was tested under a variety of conditions in order to demonstrate the capabilities of the system while running. Each test condition was evaluated on the maximum engine speed where the system could calculate all the results without loosing data for the real-time calculation and where the system could no longer write all incoming data to disk. The maximum speed of the test engine was 8000 RPM. Therefore, the test results showing an

8000 RPM limit will probably be able to reach higher engine speeds.

NI cDAQ-1939

Cylinder Count

Encoder Resolution [ppr]

Strokes

Manifold Pegging

Mean Effective Pressure

Single Zone Heat Release

Knock Sensors 100 kS/s

Cylinder Count x x

0

4

360

4 x

Medium Speed Channels 10 S/s 0

Max Speed RT Processing [RPM] 8000

Max Raw File Speed [RPM] 8000

8

4

360

4 x x x

2

20

8000

8000* x x

0

4

1800

4 x

0

8000

8000

NI cDAQ-1939

8 8 x x

2

4

1800

4 x

20

8000

8000*

Encoder Resolution [ppr]

Strokes

Manifold Pegging

Mean Effective Pressure

Single Zone Heat Release

Knock Sensors 100 kS/s

Medium Speed Channels 10 S/s x

0

0

360

4 x x

8

360

4 x x x

4

20 x

0

0

1800

4 x x

1800

4 x x x

4

20

Max Speed RT Processing [RPM] 8000 8000 5500 4000

Max Raw File Speed [RPM] 8000 8000* 8000 8000*

*Performance Optimization Settings Adjusted

8 x

0

0

3600

4 x x

3000

6000 x x

0

4

3600

4 x

0

5500

8000

8

3600

4 x x x

4

20

2500

6000* x x

2

4

3600

4 x

20

5000

6000*

© National Instruments. All rights reserved. 38

NI Combustion Analysis System Software for LabVIEW

User's Manual

3. NI CAS Software Interface

The NI CAS Software Host VI is the top level VI. It contains links to all of the NI CAS Software built in screens and provides the user with a starting place. This host always remains on top of other NI CAS Software hosts.

Deployment

Development

1. Information and controls that are always available. The user can switch between the setup and running modes, open this help documentation or see if any error conditions exist. There may also be menu items available for saving and loading calibrations and other useful functions.

2. Selection of different configurations and results groups.

© National Instruments. All rights reserved. 39

NI Combustion Analysis System Software for LabVIEW

User's Manual

3. SubHost list containing all the available NI CAS Software sub-hosts. Double clicking a name opens it if it is closed (normal) or closes it if open (bold). A single click on an open (bold) name brings it to the front.

© National Instruments. All rights reserved. 40

3.1 Offline

NI Combustion Analysis System Software for LabVIEW

User's Manual

© National Instruments. All rights reserved. 41

3.1.1 General Setup

NI Combustion Analysis System Software for LabVIEW

User's Manual

© National Instruments. All rights reserved. 42

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.1.1.1 Project Setup

The project setup options must be configured in the offline mode. Information entered here will help identify calibration files once loaded. Internal software simulation is also enabled in this window.

Engine

Operator

Project

Simulation

Specifies the name or description of the engine.

Specifies the engine operator.

Specifies the current test project.

Enables a simulation that doesn't require hardware.

© National Instruments. All rights reserved. 43

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.1.1.2 Engine Geometry Setup

The engine geometry setup must be configured in the offline mode. Information entered should be specific to the engine and test setup as it affects all of the calculations results.

Bore

Clearance Volume

Compression Ratio

Connecting Rod Length

Crown Area

Cylinder Count

Cylinder TDC

Specifies the cylinder bore.

Specifies the clearance volume of the cylinder. [Compression Ratio = (Displacement

Volume + Clearance Volume) / Clearance Volume]

Indicates the calculated compression ratio. [Compression Ratio = (Displacement

Volume + Clearance Volume) / Clearance Volume]

Specifies the connecting rod length.

Specifies the piston crown surface area relative to the bore area

Defines the number of cylinders in the engine.

Defines the cylinder Top Dead Center offsets relative to the absolute encoder offset.

© National Instruments. All rights reserved. 44

Displacement Volume

Exhaust Valve Close

Exhaust Valve Open

Head Area

Intake Valve Close

Intake Valve Open

Pin Offset

Rotations Per Cycle

Stroke

Volume File Enable

Volume File Path

NI Combustion Analysis System Software for LabVIEW

User's Manual

Indicates the calculated displacement volume. [Compression Ratio = (Displacement

Volume + Clearance Volume) / Clearance Volume]

Specifies the nominal exhaust valve closing angle.

Specifies the nominal exhaust valve opening angle.

Specifies the cylinder head surface area relative to the bore area.

Specifies the nominal intake valve closing angle.

Specifies the nominal intake valve opening angle.

Specifies the pin offset.

Defines the number of rotations per cycle. (2-Stroke = 1; 4-Stroke = 2)

Specifies the piston stroke. (Stroke = 2 * Crank Radius)

Enables use of use of a volume file instead of using the volume calculations.

Specifies the volume file to use instead of the calculations.

© National Instruments. All rights reserved. 45

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.1.1.3 Encoder Setup

The encoder setup must be configured in the offline mode. Information entered should be specific to the engine and test setup as it affects all of the calculations results.

Actual TDC Offset

Check Encoder

Cycle Resolution

Digital Filter

Deployment

Indicates the actual top dead center offset used by the engine position tracking system.

Updates the encoder debug scope. (Note: Encoder must rotate at least 4 times for the scope to update once the button is pressed)

Indicates the calculated cycle resolution.

Defines the digital glitch filter used by the engine position tracking system.

© National Instruments. All rights reserved. 46

Development

NI Combustion Analysis System Software for LabVIEW

User's Manual

Encoder Debug LED

Encoder Divide

Indicates whether the 'Measured Sample Resolution' and 'Measure Cycle Resolution' values match the 'Sample Resolution' and 'Cycle Resolution' values, respectively.

Specifies the level to divide the extrapolated resolution by in order to determine the final sample resolution (Not all combinations of encoder resolution, extrapolation level, and encoder divide are valid.)

Indicates an error in the engine position tracking configuration.

Encoder Setup Error

Encoder Extrap Level

Encoder Resolution

Encoder Setup

EPT Sim Enable

Max Speed

Specifies the level of encoder extrapolation used in the engine position tracking system. (2 valid)

Specifies the encoder resolution as it is seen by the engine position tracking.

Determines which encoder events are used by the engine position tracking system.

Enables EPT simulation of the engine encoder signals for offline testing.

Specifies the maximum speed of the engine.

Measured Sample

Resolution

Phase

Random Z Phase

Displays the number of edges counted for one encoder rotation.

Measured Cycle Resolution Displays the number of edges counted for one engine cycle.

Disable FPGA Specifies if the system is configured for acquiring data without an FPGA engine position tracking system.

Determines the method of preprocessing the encoder signal to pass only a single index pulse per cycle to the engine position tracking system.

Defines which cycle to use when using a random z.

Sample Resolution

TDC Offset cDAQ DIO Module

Indicates the calculated sample resolution based on the encoder settings.

Specifies the global TDC offset. It is commonly used to easily adjust for changes in the encoder without needing to change each cylinder TDC.

Specifies the encoder index signal name when using the Deployment Version of NI

CAS Software and a cDAQ chassis.

© National Instruments. All rights reserved. 47

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.1.1.4 Calculations

In setup mode, the user can enable or disable different groups of calculations to perform real-time calculations on the target. Each group of calculations has its own settings and results. Enabling calculation groups will increase the processor usage depending on the complexity of the calculations.

Note: Some calculations require results from another calculation group in order to work, i.e., heat release models including heat transfer simulation require the 'Gas Temp' calculation to be enabled.

© National Instruments. All rights reserved. 48

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.1.1.5 Next-Cycle Calculations

In setup mode, the user can enable or disable different groups of calculations to perform next-cycle calculations on the target. Each group of calculations has its own settings and results. Enabling calculation groups will increase the processor usage depending on the complexity of the calculations and increase the time required to provide nextcycle results.

Note: Some calculations require results from another calculation group in order to work, i.e., heat release models including heat transfer simulation require the 'Gas Temp' calculation to be enabled.

*Only available with the Development License.

© National Instruments. All rights reserved. 49

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.1.1.6 System Optimization

The performance dialog allow users to tune some of the NI CAS Software behavior with their system and setup. The current settings should work well for most configurations.

Target

Rolling Stats Size Configures the rolling statistics buffers used in trends and tables.

Buffer Size

Pre-Triggered Size

Determines the desired length of the alignment and raw file buffers.

Determines the number of cycles the raw system will maintain before a start file event.

Trigger Size Determines the number of cycles to save to a raw file at a time to improve disk performance.

Waveform Refresh Rate Configures the maximum update rate of plot data.

Statistics Refresh Rate Configures the maximum update rate of statistical data.

Host

Start Delay Delays the start of Host VI execution to allow initialization.

Plot Period

Table Period

Trend Period

Knock Period

Determines the maximum update rate of plot.

Determines the maximum update rate of tables.

Determines the maximum update rate of trends.

Determines the maximum update rate of the knock configuration display.

© National Instruments. All rights reserved. 50

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.1.2 IO Hardware Setup

© National Instruments. All rights reserved. 51

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.1.2.1 Sample Rates Setup

The sample rates setup must be configured in the offline mode. Information entered should be specific to the data acquisition hardware used as invalid inputs will cause DAQ errors.

Async Rate

Max Sync Rate

Specifies the sample rate of the asynchronous data.

Specifies the maximum sample rate of the synchronous measurement DAQ device.

Medium Speed Rate Specifies the sample rate of the medium speed DAQ.

© National Instruments. All rights reserved. 52

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.1.2.2 Sync Analog Channels Setup

The engine synchronous measurement setup is used to define all the physical channels. These measurements are sampled at even crank angle increments with respect to the engine.

1. Summary of all defined measurements.

2. Controls for manipulating the list of measurements.

3. Detailed setup of the selected measurement.

Cylinder

Disable

Filter

Gain

Max

Min

Name

Offset

Physical Channel

Polynomial

Coefficients

Scaling

Table X

Table Y

Cylinders associated with each measurement in a bitfield.

Disables data acquisition and calculations associated with each measurement.

Filter resource number associated with each measurement. (0 = No Filter)

Gain associated with each measurement when using the gain only or gain and offset scaling methods.

Maximum channel voltage range associated with each measurement.

Minimum channel voltage range associated with each measurement.

Name or description associated with each measurement.

Offset associated with each measurement when using the gain and offset scaling method.

Physical channel associated with each measurement.

Polynomial Coefficients associated with each measurement when using the polynomial scaling method.

Scaling method associated with each measurement.

Table X array associated with each measurement when using the table scaling method.

Table Y array associated with each measurement when using the table scaling method.

© National Instruments. All rights reserved. 53

NI Combustion Analysis System Software for LabVIEW

User's Manual

Terminal Configuration Terminal Configuration array associated with each measurement.

Type Measurement Type associated with each measurement.

Units Units associated with each measurement.

© National Instruments. All rights reserved. 54

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.1.2.3 Sync Digital Channels Setup

The engine synchronous digital measurement setup is used to define hardware timed digital IO associated with the engine synchronous analog inputs. These measurements are sampled at even crank angle increments with respect to the engine.

1. Summary of all defined measurements.

2. Detailed setup of the selected measurement.

Cylinder

Inverted

Name

Cylinders associated with each measurement in a bitfield.

Invert the digital signals associated with each measurement.

Name associated with each measurement.

Type Measurement Type associated with each measurement.

*Only available with the Development License.

© National Instruments. All rights reserved. 55

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.1.2.4 Async Analog Channels Setup

The time-based asynchronous measurement setup is used to define all the physical channels. These measurements are sampled at a fixed frequency.

1. Summary of all defined measurements.

2. Controls for manipulating the list of measurements.

3. Detailed setup of the selected measurement.

Cylinder

Disable

Filter

Gain

Max

Min

Name

Offset

Physical Channel

Polynomial

Coefficients

Scaling

Table X

Table Y

Cylinders associated with each measurement in a bitfield.

Disables data acquisition and calculations associated with each measurement.

Filter resource number associated with each measurement. (0 = No Filter)

Gain associated with each measurement when using the gain only or gain and offset scaling methods.

Maximum channel voltage range associated with each measurement.

Minimum channel voltage range associated with each measurement.

Name or description associated with each measurement.

Offset associated with each measurement when using the gain and offset scaling method.

Physical channel associated with each measurement.

Polynomial Coefficients associated with each measurement when using the polynomial scaling method.

Scaling method associated with each measurement.

Table X array associated with each measurement when using the table scaling method.

Table Y array associated with each measurement when using the table scaling method.

© National Instruments. All rights reserved. 56

NI Combustion Analysis System Software for LabVIEW

User's Manual

Terminal Configuration Terminal Configuration array associated with each measurement.

Type Measurement Type associated with each measurement.

Units Units associated with each measurement.

© National Instruments. All rights reserved. 57

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.1.2.5 Async Digital Channels Setup

The time-based asynchronous digital measurement setup is used to define hardware timed digital IO associated with the asynchronous analog inputs. These measurements are sampled at a fixed frequency.

1. Summary of all defined measurements.

2. Detailed setup of the selected measurement.

Cylinder

Inverted

Cylinders associated with each measurement in a bitfield.

Invert the digital signals associated with each measurement.

Name Name associated with each measurement.

Type Measurement Type associated with each measurement.

*Only available with the Development License.

© National Instruments. All rights reserved. 58

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.1.2.6 Medium Speed Channels Setup

The time-based medium speed measurement setup is used to define all the physical channels. Medium speed are intended for sampling test cell and other auxiliary signals. These measurements are sampled at a fixed frequency.

1. Summary of all defined measurements.

2. Controls for manipulating the list of measurements. Enable/Disable engine cycle averages and statistic calculations.

3. Detailed setup of the selected measurement.

CJC Channel

CJC Source

CJC Value

Disable

Filter Cutoff

Gain

Max

Min

Name

Offset

Physical Channel

Cold junction compensation channel associated with each measurement when using a channel cold junction compensation source.

Cold junction compensation source associated with each measurement.

Cold junction compensation value associated with each measurement when using a constant cold junction compensation source.

Disables data acquisition and calculations associated with each measurement.

Knock Threshold for Each Cylinder

Gain associated with each measurement.

Maximum voltage, current, or temperature associated with each measurement.

Minimum voltage, current, or temperature associated with each measurement.

Name or description associated with each measurement.

Offset associated with each measurement.

Physical channel associated with each measurement.

© National Instruments. All rights reserved. 59

NI Combustion Analysis System Software for LabVIEW

User's Manual

Save Trigger

Scaling

Enables the channel to be used to trigger the start of a file save. Each index is associated with each measurement.

Scaling method associated with each measurement.

Terminal

Configuration

Terminal configuration associated with each measurement.

Thermocouple Type Thermocouple type associated with each measurement.

Units Units associated with each measurement.

© National Instruments. All rights reserved. 60

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.1.2.7 FPGA Stream Setup

The FPGA setup is used to define data streamed from the FPGA. The measurements are defined in the FPGA when using an FPGA with the Development Version of NI CAS Software. Defining them in the FPGA setup allows the

Development Version of NI CAS Software to calculate cycle averages and statistics for the display and summary files.

1. Summary of all defined measurements.

2. Controls for manipulating the list of measurements. Enable/Disable engine cycle averages and statistic calculations.

3. Detailed setup of the selected measurement.

Gain

ID

Name

Offset

Gain associated with each measurement.

ID associated with each FPGA measurement.

Name or description associated with each measurement.

Offset associated with each measurement.

Units Units associated with each measurement.

*Only available with the Development Version of NI CAS Software

© National Instruments. All rights reserved. 61

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.1.2.8 Analog Output Channels Setup

The analog output setup defines analog outputs channels. These channels link to calculated results in NI CAS

Software based on name. The recent names contain a list of available results from the last time the system ran.

1. Summary of all defined outputs.

2. Controls for manipulating the list of outputs.

3. Detailed setup of the selected outputs.

AO Type

Cylinder

Disable

Gain

Max

Min

Name

Offset

Physical Channel

Type

Analog output type associate with the measurement.

Cylinder associated with each measurement.

Disables data acquisition and calculations associated with each measurement.

Gain associated with each measurement.

Maximum voltage range associate with the measurement.

Minimum voltage range associate with the measurement.

Name or description associated with each measurement.

Offset associated with each measurement.

Physical channel associated with each measurement.

Measurement Type associated with each measurement.

© National Instruments. All rights reserved. 62

3.2 Online

NI Combustion Analysis System Software for LabVIEW

User's Manual

© National Instruments. All rights reserved. 63

3.2.1 Settings

NI Combustion Analysis System Software for LabVIEW

User's Manual

© National Instruments. All rights reserved. 64

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.2.1.1 Motoring and TDC Offset Settings

The Motoring / TDC Offset window is a tool to assist the user in correctly phasing sampled engine-synchronous data with calculated volume data. In general, this window should only be utilized while the engine is 'motoring,' or spinning without firing. Several methods for finding the TDC Offset include positioning the peak pressure with the use of a thermodynamic loss angle, positioning a TDC probe signal, and manual input.

1. Selection of the reference cylinder to be used for calculating a TDC Offset.

2. Relevant motoring values based on the statistical mean.

3. Calculated polytropic coefficients for reference.

4. New TDC Offset settings using Peak Pressure or a TDC Probe.

5. Current and calculated TDC Offset values.

6. Detailed P-V diagram, including the calculated compression and expansion polytropic coefficient lines.

7. Plot of cylinder pressure and TDC probe (if selected) vs. engine position.

Actual TDC Offset

Calc TDC Offset

Indicates the actual top dead center offset used by the engine position tracking system.

Indicates the calculated (new) TDC offset based on the TDC Offset reference and associated parameters.

.

© National Instruments. All rights reserved. 65

NI Combustion Analysis System Software for LabVIEW

User's Manual

COV of IMEP dPoly dPoly High dPoly Low

IMEP

Loss Angle

Out of Range

Indicates the statistical coefficient of variation of the indicated mean effective pressure

(net) of the reference cylinder.

Indicates the difference between the statistical mean of calculated compression and expansion polytropic coefficients.

Specifies the maximum threshold for the difference between compression and expansion polytropic coefficients.

Specifies the minimum threshold for the difference between compression and expansion polytropic coefficients.

Indicates the statistical mean of indicated mean effective pressure (net) of the reference cylinder.

Specifies the difference between peak cylinder pressure and cylinder TDC due to heat transfer losses; commonly referred to as the thermodynamic loss angle.

Indicates whether the associated polytropic coefficient is within the stated maximum and minimum threshold values.

Peak Pressure Indicates the statistical mean of peak pressure of the reference cylinder.

Peak Pressure Location Indicates the statistical mean of location of peak pressure of the reference cylinder.

PolyC

PolyC High

Indicates the statistical mean of calculated polytropic coefficient of the compression stroke

(based on the logarithmic P-V diagram)

Specifies the maximum threshold for the calculated polytropic coefficient of the compression stroke.

PolyC Low

PolyE

Specifies the minimum threshold for the calculated polytropic coefficient of the compression stroke.

Indicates the statistical mean of calculated polytropic coefficient of the expansion stroke

(based on the logarithmic P-V diagram)

PolyE High

PolyE Low

Specifies the maximum threshold for the calculated polytropic coefficient of the expansion stroke.

Specifies the minimum threshold for the calculated polytropic coefficient of the expansion stroke.

Reference Cylinder

Rolling Stats Size

Set TDC Offset

TDC Fine Adjust

Specifies the cylinder used as a reference for TDC offset settings.

Specifies the size of rolling statistics buffers.

Sets a new TDC Offset value (indicated by the Calc TDC Offset). Because the TDC

Offset must be configured in the Offline mode, the DAQ software must be reinitialized.

Specifies the TDC fine adjustment. A TDC offset may force resampling data which can be slow.

TDC Offset Specifies the global TDC Offset. It is commonly used to easily adjust for changes in the encoder without needing to change each cylinder TDC.

TDC Offset Change Indicates the difference between the current TDC offset and the new Calc TDC Offset.

TDC Offset Reference Specifies the method used to calculate a new TDC Offset.

© National Instruments. All rights reserved. 66

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.2.1.2 Async Conversion Settings

The async conversion settings define the method of converting signals to synchronous or asynchronous types depending on what types of signals are available.

Conversion Specifies the method used to convert synchronous data to asynchronous data.

© National Instruments. All rights reserved. 67

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.2.1.3 Pegging Settings

Many of the sensors used for in-cylinder applications are relative or dynamic measurements. They are accurate in representing the change in pressure over a short period but do not represent an absolute vale. To compensate, pegging (calculating a dynamic offset) is used.

1. Detailed setup of the selected measurement.

2. Plot of current signals and windows.

3. Selection of cylinder to display.

Location

Pegging

Pegging Pressure

Specifies the location used to peg cylinder pressure when using constant and synchronous

MAP pegging.

Specifies the method used to peg cylinder pressure.

Specifies the pressure used to peg cylinder pressure when using constant pegging.

Polytropic Exponent Specifies the polytropic exponent used for polytropic pegging.

Window The crank angle window size used to average noise in synchronous waveform measurements.

© National Instruments. All rights reserved. 68

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.2.1.4 Filter Settings

The filter settings define all the filters for engine synchronous and time-based asynchronous measurements.

Each measurement can be configured to a filter resource. The filter resources can be attached to a one or more measurements.

Filter

Frequency

N

1. Detailed settings for each filter resource.

2. Plot of current signals and windows.

3. Selection of filter resource and signal to plot.

Order

Defines the type of filter used.

Defines the filter frequency as a percent of the nyquist frequency. This value is only valid when using FIR and IIR filters.

Defines the number of cycles to include in the rolling average or the number of samples to include in the boxcar average.

Defines the order of the filter when using the FIR and IIR filters.

© National Instruments. All rights reserved. 69

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.2.1.5 Pressure Metrics Settings

The pressure metrics settings define parameters for the pressure metrics calculation group.

1. Detailed settings for the basic calculation group.

2. Plot of current signals and windows.

Endpoint Window

Exhaust Pressure End

Exhaust Pressure Start

Intake Pressure End

Intake Pressure Start

Peak Pressure

Peak Pressure End

Peak Pressure Start

Polytropic

Polytropic Compression End

Polytropic Compression Start

Polytropic Expansion End

Specifies the size of the window used to average the endpoints when calculating the polytropic exponents.

Specifies the end of the exhaust pressure calculation.

Specifies the start of the exhaust pressure calculation.

Specifies the end of the intake pressure calculation.

Specifies the start of the intake pressure calculation.

Specifies the method used to calculate the peak pressure.

Specifies the end of the peak pressure window.

Specifies the start of the peak pressure window.

Specifies the method used to calculate the polytropic exponents.

Specifies the end of the polytropic compression calculation.

Specifies the start of the polytropic compression calculation.

Specifies the end of the polytropic expansion calculation.

© National Instruments. All rights reserved. 70

Polytropic Expansion Start

NI Combustion Analysis System Software for LabVIEW

User's Manual

Specifies the start of the polytropic expansion calculation.

© National Instruments. All rights reserved. 71

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.2.1.6 Unit Conversions Settings

The unit conversion dialog allows the user to define a set of unit conversion rules. The rules affect the tables, trends, and plots. They do not change the units of settings or results in a file.

© National Instruments. All rights reserved. 72

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.2.1.7 Temperature Settings

The temperature settings define how the in-cylinder temperature estimation is calculated.

Exhaust Pressure Pressure of the intake gas at the intake valve.

Exhaust Temperature Temperature of the exhaust gas at the exhaust valve.

Intake Pressure

Intake Temperature

Residual Fraction

Window

Pressure of the exhaust gas at the exhaust valve.

Temperature of the intake gas at the intake valve.

Fraction of exhaust gas remaining in the combustion chamber after the exhaust event.

The crank angle window size used to average noise in synchronous waveform measurements.

© National Instruments. All rights reserved. 73

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.2.1.8 Heat Release Settings

The heat release settings define what settings are used for the various methods of calculating heat release.

C1c

C1e

C1ge

C2c

C2e

C2ge

End Angle

End of Combustion

Woschni Coefficient 1 for Compression (Default = 2.28).

Woschni Coefficient 1 for Combustion and Expansion (Default = 2.28).

Woschni Coefficient 1 for Gas Exchange (Default = 6.18).

Woschni Coefficient 2 for Compression (Default = 0.0).

Woschni Coefficient 2 for Combustion and Expansion (Default = 0.00324).

Woschni Coefficient 2 for Gas Exchange (Default = 0.0).

Specifies the angle to end looking for the end of combustion.

Specifies the method used to determine the end of combustion.

Heat Release

Heat Transfer

Specifies the method used to calculate heat release.

Defines the heat transfer when using the constant Heat Transfer Correlation method.

Heat Transfer Correlation Specifies the method used to calculate the Heat Transfer Correlation.

N End Specifies the number of samples to use when determining the end of combustion.

N Start

Polytropic Correlation

PreChamber Volume

Smoothing

Specifies the number of samples to use when determining the start of combustion.

Specifies the method use to calculate the polytropic exponent.

Specifies the volume of the prechamber used in dual transducer calculations.

Pressure waveform smoothing factor as a percent of one engine cycle.

© National Instruments. All rights reserved. 74

b

Start Angle

Start of Combustion

User Heat Release VI

Wall Temperature

Wall Temperature BDC

Wall Temperature Profile

Wall Temperature TDC a

NI Combustion Analysis System Software for LabVIEW

User's Manual

Specifies the angle to start looking for the start of combustion.

Specifies the method used to determine the start of combustion.

Specifies the file location of the user heat release VI, if used.

Specifies the Wall Temperature when using the constant Wall Temperature Profile.

Specifies the Bottom Dead Center Wall Temperature when using the linear Wall

Temperature Profile

Specifies the method used to calculate the cylinder Wall Temperature Profile.

Specifies the Top Dead Center Wall Temperature when using the linear Wall

Temperature Profile

Defines the Polytropic Exponent Correlation "a" Value when using custom Polytropic

Correlation.

Defines the Polytropic Exponent Correlation "b" Value when using custom Polytropic

Correlation.

© National Instruments. All rights reserved. 75

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.2.1.9 Knock Settings

The knock settings determine how knock is detected. The knock settings dialog provides information and displays that are helpful for calibrating the knock settings.

1. Summary of settings for each cylinder.

2. Detailed setup of the selected measurement.

3. Calibration setup displays.

4. Hold and clear for up to 7 cycles. Pressing the buttons captures the current waveforms for comparison.

High Cutoff Frequency Specifies the High Cutoff Frequency of the knock filter for each cylinder.

Knock End Specifies the crank angle to end the knock window for each cylinder.

Knock Start Specifies the crank angle to start the knock window for each cylinder.

Low Cutoff Frequency Specifies the Low Cutoff Frequency of the knock filter for each cylinder.

Minimum Reference

Reference End

Reference Start

Threshold

Specifies the Minimum Reference Value used to remove noise for each cylinder.

Specifies the crank angle to end the reference window for each cylinder.

Specifies the crank angle to start the reference window for each cylinder.

Specifies the knock threshold for each cylinder.

© National Instruments. All rights reserved. 76

NI Combustion Analysis System Software for LabVIEW

User's Manual

Calibrating knock is a delicate process of capturing various degrees of knock and comparing them to determine where the unacceptable level of knock occurs. Changing settings will reprocess all the held data so the new settings can be evaluated over the range of operating conditions. The process of calibrating knock starts with setting up windows for checking for knock and reference noise. The Signal page shows the current cycle of pressure data and the acoustic waveform. The knock window should be located around TDC. The reference window should be located away from noise caused by valve closings and other noisy events.

The next step in calibrating knock is to determine the knocking frequency. The frequency magnitude should be reality stable unless knocking. Therefore, the filter frequencies should include the knocking event but not other events.

The filter cutoffs page displays the FFT of the for the knock and reference windows. The first three theoretical fundamental frequencies (based on cylinder bore) are calculated and displayed for reference.

© National Instruments. All rights reserved. 77

NI Combustion Analysis System Software for LabVIEW

User's Manual

Next, the filter results for the knock and reference window are displayed on the filter results page.

© National Instruments. All rights reserved. 78

NI Combustion Analysis System Software for LabVIEW

User's Manual

Last, the filtered window results are integrated and compared. The threshold should be set to determine where knock starts. The threshold is removed to get the final knock value. Any value above zero is considered knock.

Greater knock values indicate greater levels of knock. The threshold page shows the results of the integration and the raw and final results of the comparison.

© National Instruments. All rights reserved. 79

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.2.1.10 Cam Settings

The cam settings are used to calculate cam phasing. The system should be set up for each cylinder separately. The setup button analyzes the cam signal and generates an array of angles for rising and falling edges to compare to calculate the phasing. The baseline settings should be set when the phaser control is turned off or disconnected.

1. Plot of current signals and rising and falling edges.

2. Selection of cylinder to display.

3. Detailed setup of the selected cylinder.

Exhaust Cam Edge Angles Specifies the angle for each exhaust cam pulse of each cylinder.

Exhaust Cam Edge Count Specifies the number of exhaust cam pulses for each cylinder.

Exhaust Cam Edge Directions Specifies the direction of exhaust cam pulse for each cylinder. Each cylinders data is stored in a bit field corresponding to each pulse.

Intake Cam Edge Angles

Intake Cam Edge Count

Specifies the angle for each input cam pulse of each cylinder.

Specifies the number of intake cam pulses for each cylinder.

Intake Cam Edge Directions Specifies the direction of intake cam pulse for each cylinder. Each cylinders data is stored in a bit field corresponding to each pulse.

© National Instruments. All rights reserved. 80

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.2.1.11 Injection Settings

The injection settings define how injection waveforms are processed. The injection calculations measure starting angle, duration, and fuel flow for each injection.

Fuel Rail Pressure

Fuel Rail Pressure

Source

Min Injection

Signal

Type

X-Fuel Pressure

Y-Duration

Z-Fuel Flow

Defines the fuel rail pressure of the injectors.

Determines the source of the fuel rail pressure used in determining fuel flow.

Defines the minimum injection width.

Defines the injector signal type.

Defines the injector type.

Defines the X-Axis (Fuel Pressure) of the 2d injector calibration table.

Defines the Y-Axis (Duration) of the 2d injector calibration table.

Defines the Z-Axis (Fuel Flow) of the 2d injector calibration table.

© National Instruments. All rights reserved. 81

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.2.1.12 Spark Settings

The spark setting determine how spark signals are processed. The spark calculations determine the spark angel and dwell for each spark.

Min Dwell

Restrike Delay

Signal

Defines the minimum dwell width.

Defines the maximum restrike delay.

Defines the spark signal type.

© National Instruments. All rights reserved. 82

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.2.1.13 Misfire Settings

The misfire settings determine how a misfire event is determined.

Misfire

Threshold

Specifies the method to use for Misfire detection.

Specifies the threshold used to detect a misfire. The use of the value depends on the misfire method used.

© National Instruments. All rights reserved. 83

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.2.1.14 Simulation Settings

The simulation settings allow the user to control how simulated waveforms are generated. The simulation is enabled on the engine setup page.

1. Speed and load settings.

2. Simulated settings mode. Lookup tables adjust detailed settings based on speed and load. Run profile runs the pre-defined profile.

3. Detailed simulation settings.

4. Pre-defined profile.

Cam Start

Exhaust Cam

Fuel Rail Pressure

Injection Duration

Injection Location

Intake Cam

Specifies the simulated cam start.

Specifies the simulated exhaust cam offset.

Specifies the simulated fuel rail pressure.

Specifies the simulated injection duration.

Specifies the simulated injection locations

Specifies the simulated intake cam offset.

Manifold Absolute Pressure Specifies the simulated manifold absolute pressure.

PWM Duty Cycle Specifies the simulated pulse width width measurement duty cycle.

© National Instruments. All rights reserved. 84

NI Combustion Analysis System Software for LabVIEW

User's Manual

PWM Frequency

Spark Dwell

Spark Location

Speed

Specifies the simulated pulse width width measurement frequency.

Specifies the simulated spark dwell.

Specifies the simulated spark location.

Specifies the simulated engine speed.

Synchronous Pump Duration Specifies the simulated synchronous pump duration.

Synchronous Pump Start Specifies the simulated synchronous pump start.

© National Instruments. All rights reserved. 85

3.2.2 File Save

NI Combustion Analysis System Software for LabVIEW

User's Manual

© National Instruments. All rights reserved. 86

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.2.2.1 Raw File Save

NI CAS Software raw files contain all of the data as it comes from the DAQ system and all of the settings entered by the user. This data can be used to generate summary data. Because all of the data is saved in a raw format, calibrations and other settings can be modified and applied the calculations when reprocessing. However, the data in the file need some processing before it is useful in most user applications. NI CAS Software contains several applications, examples, and an API for using raw data files.

Start-Stop File

Standby / Writing

Starts saving a file if currently stopped or stops saving a file if currently stopped.

Displays the state of the file writing process.

New File / Overwrite Indicates if a new file will be written or an old file will be overwritten.

Sum + Raw Presses the "Start-Stop File" buttons on "Raw File" and "Sum File" dialogs at the same time.

File Path

Path

File Name

Comments

Single / Continuous

Current files path and name when saving.

Location on the target system where data will be saved.

Name of saved files. "XXX" is replaced by the "File Counter" and standard data/time formats (%c) are applied to the name.

User comments added to the file.

Single - One file is written and saving stops. / Continuous - A new file is started when the previous one finishes. File Part increments by on for each file. The saving process must be stopped manually.

© National Instruments. All rights reserved. 87

NI Combustion Analysis System Software for LabVIEW

User's Manual

File Part

Size Limit

Time Limit

Indicates the current part of a continuous multi-part save.

Enables a size limit on file saving and defines the maximum file size.

Enables a time limit on file saving and defines the maximum time.

Cycle Limit Enables a cycle limit on file saving and defines the maximum number of cycle.

File Counter Indicates the current file count.

Reset Counter Value Desired value to set "File Counter" to when "Reset Counter" button is pressed.

Reset Counter Resets the file counter to the "Reset Counter Value".

File Progress

Process File

Indicates the approximate status of the file save compared with the file limit conditions.

Contains a path to a VI on the target system that will be used to process the files after a save operation. Leave it blank to disable file processing.

Indicates the current file that is processing and any files waiting to be processed.

File

Error

Data/Time Format:

%X (locale-specific time)

Indicates any error associated with file processing.

%H (hour, 24-hour clock)

%I (hour, 12-hour clock)

%M (minute)

%S (second)

%<digit>u (fractional seconds with <digit> precision)

%p (a.m./p.m. flag)

%x (locale-specific date)

%y (year within century)

%Y (year including century)

%m (month number)

%b (abbreviated month name)

%d (day of month)

%a (abbreviated weekday name)

© National Instruments. All rights reserved. 88

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.2.2.2 Summary File Save

NI CAS Software summary files contain all of the calculated results all of the settings entered by the user. The file also contains statistics on all the results. Ensemble averages are included for user reference.

Start-Stop File Starts saving a file if currently stopped or stops saving a file if currently stopped.

Standby / Writing Displays the state of the file writing process.

New File / Overwrite Indicates if a new file will be written or an old file will be overwritten.

Sum + Raw

File Path

Presses the "Start-Stop File" buttons on "Raw File" and "Sum File" dialogs at the same time.

Current files path and name when saving.

Path

File Name

Comments

Single / Continuous

File Part

Size Limit

Location on the target system where data will be saved.

Name of saved files. "XXX" is replaced by the "File Counter" and standard data/time formats (%c) are applied to the name.

User comments added to the file.

Single - One file is written and saving stops. / Continuous - A new file is started when the previous one finishes. File Part increments by on for each file. The saving process must be stopped manually.

Indicates the current part of a continuous multi-part save.

Enables a size limit on file saving and defines the maximum file size.

© National Instruments. All rights reserved. 89

NI Combustion Analysis System Software for LabVIEW

User's Manual

Time Limit

Cycle Limit

Enables a time limit on file saving and defines the maximum time.

Enables a cycle limit on file saving and defines the maximum number of cycle.

File Counter Indicates the current file count.

Reset Counter Value Desired value to set "File Counter" to when "Reset Counter" button is pressed.

Reset Counter Resets the file counter to the "Reset Counter Value".

File Progress

Process File

Indicates the approximate status of the file save compared with the file limit conditions.

Contains a path to a VI on the target system that will be used to process the files after a save operation. Leave it blank to disable file processing.

Indicates the current file that is processing and any files waiting to be processed.

File

Error

Data/Time Format:

%X (locale-specific time)

Indicates any error associated with file processing.

%H (hour, 24-hour clock)

%I (hour, 12-hour clock)

%M (minute)

%S (second)

%<digit>u (fractional seconds with <digit> precision)

%p (a.m./p.m. flag)

%x (locale-specific date)

%y (year within century)

%Y (year including century)

%m (month number)

%b (abbreviated month name)

%d (day of month)

%a (abbreviated weekday name)

© National Instruments. All rights reserved. 90

3.2.3 Status

NI Combustion Analysis System Software for LabVIEW

User's Manual

© National Instruments. All rights reserved. 91

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.2.3.1 Engine

The engine status display shows the current speed of the engine. It also shows the running time and engine cycle.

© National Instruments. All rights reserved. 92

3.2.3.2 Resources

The resources display shows the status of the system hardware resources.

NI Combustion Analysis System Software for LabVIEW

User's Manual

Free Disk Space

Core

Free Space on the C Drive

CPU use for each CPU core (RT only)

CPU Average system CPU use (RT only)

RAM Available system RAM (RT only).

*Only available with the Development License.

© National Instruments. All rights reserved. 93

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.2.3.3 EPT

The EPT (engine position tracking) status display indicates the state of the encoder tracking. This function is only available when using an FPGA.

A

B

Crank Count

Crank Count Max

Crank Count Min

Crank Position

Cycle

Cycle Period

FPGA Time

Gate-Reset

Max CAT

Overspeed

Indicates the state of the encoder A signal.

Indicates the state of the encoder B signal.

Indicates the current crank count of the engine position tracking system.

Indicates the maximum crank count observed after starting the engine position tracking system.

Indicates the minimum crank count observed after starting the engine position tracking system.

Indicates the current position of the engine position tracking system.

Indicates the current cycle after starting the engine position tracking system.

Indicates the current cycle period measured by the engine position tracking system.

Indicates the current FPGA timestamp.

Indicates the state of the encoder Gate/Reset signal.

Indicates the maximum crank angle ticks of the engine position tracking system.

Indicates an overspeed state of the engine position tracking system.

Stalled

Start Time

Indicates a stalled state of the engine position tracking system.

Indicates the start time of the current DAQ sampling task according to the FPGA timestamp.

Sync Indicates a synchronized state of the engine position tracking system.

Z Indicates the state of the encoder Z signal.

*Only available with the Development License.

© National Instruments. All rights reserved. 94

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.2.3.4 Execution

The execution status display indicates execution time of each processing and calculation step. The calculations can be enabled or disabled using

Calculations.vi

.

1. Calculation Time - Calculation time for each processing or calculation step.

2. Name and Color - Name and color of the processing or calculation step.

3. Calculation Time - Graphical representation of calculation time. The plot maximum is the maximum allotted time available to finish the calculations.

© National Instruments. All rights reserved. 95

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.2.3.5 Buffer

The buffer status display indicates the state of the NI CAS Software buffers. The NI CAS Software buffers should not overflow under normal operation. Each buffer is used in a different part of the system.

1. Buffer Summary - Each buffer holds and delivers data to a different part of the NI CAS Software.

2. Alignment and Raw Summary - The alignment and raw file buffers are many smaller buffers to hold data from different sources.

3. Next-Cycle Control Data Ready Angle - The estimated angle where next cycle results are available.

The Alignment and Raw buffers gather and hold data from the DAQ system and waits for the desired number of cycles or data to become available. The data is then distributed to other functions waiting on it. Each source of data writes the data to its own smaller buffer. The sizes of these buffers is determined by the maximum sample rate calculated from the engine speed and sample resolution or the sample frequency.

Next-Cycle control data is handed off to the user program where it can be used for whatever control strategy needs it. Data for processing real-time results is passed to the processing code where it performs all the required calculations and hands the results to the display and summary file functions.

The raw data streaming has direct access to the alignment buffers and and pulls the buffers directly to disk.

© National Instruments. All rights reserved. 96

NI Combustion Analysis System Software for LabVIEW

User's Manual

© National Instruments. All rights reserved. 97

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.2.3.6 Loop

The loop status display indicates execution status of each NI CAS Software loop.

1. Loop Count - Shows the current iteration of the specified loop.

2. Loop Period - Shows the current period of the specified loop.

3. Loop Time - Shows the current execution time of the specified loop.

© National Instruments. All rights reserved. 98

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.2.3.7 Error

The error status display shows an error and warning message for each loop in the NI CAS Software. The errors are accompanied with an error number and an error message. An new error state will cause the window to open.

© National Instruments. All rights reserved. 99

3.3 Results

NI Combustion Analysis System Software for LabVIEW

User's Manual

© National Instruments. All rights reserved. 100

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.3.1 X-Axis

All plots using "Crank Angle" as the X-axis can be modified collectively by using the plot scaling tool at the top of the

"Plots" tab. The plot scaling tool contains several preset values that are commonly used to look at data, as well as a custom setting which can be used to enter values not included in the presets.

© National Instruments. All rights reserved. 101

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.3.2 Plots

Plots display data in array form. The NI CAS Software contains several different typed of plots that are used for different kinds of data. Plots using "Crank Angle" as the x-axis have global settings using the X-Axis controls. Most plots are resizable by dragging the corner or side of the window.

This type of plot displays analog results for a single cylinder and a single cycle of data at a time.

1. Plot Legend - Displays plot names and units with the ability to turn off a plot.

2. Plot Data - Data display area.

3. Plot Controls - Controls for controlling zoom and cursors.

4. Cylinder Selection - Select the cylinder to display.

5. Y-Axis mode - Select between using absolute units or % of range for the Y-axis.

© National Instruments. All rights reserved. 102

NI Combustion Analysis System Software for LabVIEW

User's Manual

This type of plot displays digital results for a single cylinder of data at a time.

1. Plot Legend - Displays plot names with the ability to turn off a plot.

2. Plot Data - Data display area.

3. Plot Controls - Controls for controlling zoom and cursors.

4. Cylinder Selection - Select the cylinder to display.

5. Y-Axis mode - Select between using a separate or combined Y-axis.

*Only available with the Development License.

© National Instruments. All rights reserved. 103

NI Combustion Analysis System Software for LabVIEW

User's Manual

This plot displays the results of the volume calculations or loading a volume file.

1. Volume - Cylinder volume as a function of crank angle.

2. dVolume - Differential cylinder volume as a function of crank angle.

3. Cylinder Area - Cylinder, head, and piston area as a function of crank angle.

© National Instruments. All rights reserved. 104

NI Combustion Analysis System Software for LabVIEW

User's Manual

This type of plot displays the results of a specific type of signal for all the cylinders and engine average for a single cycle.

1. Plot Legend - Displays plot names and units with the ability to turn off a plot.

2. Plot Data - Data display area.

3. Plot Controls - Controls for controlling zoom and cursors.

© National Instruments. All rights reserved. 105

NI Combustion Analysis System Software for LabVIEW

User's Manual

This plot displays the pressure vs. volume for all the cylinders and engine average for a single cycle.

1. Plot Legend - Displays plot names and units with the ability to turn off a plot.

2. Plot Data - Data display area.

3. Plot Controls - Controls for controlling zoom and cursors.

4. Axis - Changes the axis to a log or linear scale.

© National Instruments. All rights reserved. 106

NI Combustion Analysis System Software for LabVIEW

User's Manual

This plot displays the pressure vs. volume for a single cylinder and a single cycle.

1. Plot Legend - Displays the name and color for each stroke.

2. Plot Data - Data display area.

3. Plot Controls - Controls for controlling zoom and cursors.

4. Cylinder Selection - Select the cylinder to display.

5. Axis - Changes the axis to a log or linear scale.

© National Instruments. All rights reserved. 107

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.3.3 Tables

Tables contain all of the calculated values and rolling statistics for each result. The results are grouped by calculation group that can be turned on or off. See

Calculations.vi

to turn or off the calculation groups.

1. Show Statistics - Turns on or off rows of statistics.

2. Parameter - A list of parameters calculated by the specific calculation group.

3. Values - Calculation results for each cylinder and the engine average for multi-cylinder engines.

© National Instruments. All rights reserved. 108

NI Combustion Analysis System Software for LabVIEW

User's Manual

3.3.4 Trend Charts

Trend charts contain a history of all the calculated values and rolling statistics. The trend chart captures the current values at a fixed rate. Therefore, they are good for looking at global trends and not for individual cycle events. The results are grouped by calculation group that can be turned on or off. See

Calculations.vi

to turn or off the calculation groups.

1. Parameter - A list of parameters calculated by the specific calculation group.

2. Show Statistics - Turns on or off rows of statistics.

3. Values - History of calculated results.

4. Plot Controls - Controls for controlling zoom and cursors.

© National Instruments. All rights reserved. 109

NI Combustion Analysis System Software for LabVIEW

User's Manual

4. Processing and Calculations

© National Instruments. All rights reserved. 110

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.1 Cylinder Volume

Cylinder volume is calculated using the following equation for the typical crank-slider mechanism (no wrist-pin offset)

1,2

:

For engines requiring a wrist-pin offset, the following geometry calculations are used: where:

© National Instruments. All rights reserved. 111

NI Combustion Analysis System Software for LabVIEW

User's Manual

1. Heywood, J. B., Internal Combustion Engine Fundamentals. McGraw Hill, Inc., New York, NY. 1988.

2. Stone, R., Introduction to Internal Combustion Engines, 3rd Edition. Copyright Richard Stone, 1999.

© National Instruments. All rights reserved. 112

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.2 Waveform Filters

Four different filter types with customizable parameters can be used to remove unwanted noise from the synchronous and asynchronous signals: Boxcar, Rolling N Cycles, Forward and Reverse IIR, and FIR Filter with

Rollback.

© National Instruments. All rights reserved. 113

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.2.1 Boxcar

The 'Boxcar' filter requires 'N' points for input. This filter, also known as a 'moving average,' is a very simple FIR filter which smoothes a signal by 'marching' through the waveform and averaging 'N' points before and after each given point (including the point itself).

© National Instruments. All rights reserved. 114

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.2.2 Rolling N Cycles

The 'Rolling N Cycles' filter requires 'N' cycles for input. This filter is an ensemble average of the last 'N' consecutive cycles, as shown in the following equation:

Note: The 'Rolling N Cycles' filter tends to be resource intensive, scaling with the number of cycles used.

© National Instruments. All rights reserved. 115

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.2.3 Forward and Reverse IIR

The 'Forward and Reverse Infinite Impulse Response (IIR)' filter requires filtering frequency (lowpass) and filter order inputs. The Butterworth filtering method is used, with a sampling frequency of 200 Hz. The filter order dictates the response of the signal roll-off, where a higher order has a steeper roll-off.

This filter is passed in both forward and reverse directions to avoid shifting the phase of the waveform.

© National Instruments. All rights reserved. 116

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.2.4 FIR Filter with Rollback

The 'FIR Filter with Rollback' requires filtering frequency (lowpass) and filter order inputs. This filter is a backwardlooking 'moving average' which smoothes a signal by 'marching' through the waveform and averaging 'N - 1' points before each given point (including the point itself). In this case, 'N' is also the filter order.

This filter method shifts the phase of the waveform N/2 points to the right, therefore rollback is necessary to correct the phase of the signal.

© National Instruments. All rights reserved. 117

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.3 Cylinder Pressure Pegging

In the case that in-cylinder pressure is measured using a dynamic pressure transducer (e.g., piezoelectric), the captured waveform must be 'pegged' to an absolute value in order to obtain accurate results. Using this software, cylinder pressure can be pegged using a constant value, synchronous manifold absolute pressure (MAP) signal, or a polytropic coefficient. Note: If a pre-chamber pressure is used, it will be pegged in the same manner as the primary cylinder pressure.

© National Instruments. All rights reserved. 118

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.3.1 Constant

The 'Constant' pegging setting requires a constant, scalar value as the pegging reference, a pegging location, and a pegging window.

The pegging location (typically near a relatively quiescent period within the cycle and while the intake valve(s) are open) specifies the crank angle at which the pegging reference will exactly equal the average of the cylinder pressure waveform over a given pegging window. The pegging window is centered about the pegging location.

© National Instruments. All rights reserved. 119

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.3.2 Synchronous MAP

The 'Synchronous MAP' pegging setting requires a configured sync analog channel (Manifold Absolute Pressure kPa) as the pegging reference, a pegging location, and a pegging window.

The pegging location (typically near a relatively quiescent period within the cycle and while the intake valve(s) are open) specifies the crank angle at which the pegging reference will exactly equal the average of the cylinder pressure waveform over a given pegging window. The pegging window is centered about the pegging location.

© National Instruments. All rights reserved. 120

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.3.3 Polytropic

The 'Polytropic' pegging setting requires a pegging location, a pegging window, and a constant polytropic coefficient to define the pegging reference.

The pegging location / window should be positioned during the compression stroke after the intake valve is closed, e.g., from -90 to -60 DATDC.

The following calculations are used to define the pegging reference:

Where location 1 and 2 are the average values at the respective endpoints of the pegging window specified, 'P' is pressure, 'V' is volume, and 'n' is the desired polytropic coefficient. At each endpoint, a smaller window is specified of which the average value is taken as the endpoint value (2 CAD means 2 CAD before and after a given point).

Finally, the cylinder pressure is pegged by adding P ref

to the original unpegged pressure waveform(s).

© National Instruments. All rights reserved. 121

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.4 Pressure Metrics

Several important results are derived from the pressure waveform, including peak pressure, peak pressure location, peak pressure rise rate, peak pressure rise rate location, polytropic coefficient of compression, and polytropic coefficient of expansion.

The TDC probe location result is calculated and recorded with the pressure metrics as it relates to the phasing of the pressure and volume waveforms.

© National Instruments. All rights reserved. 122

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.4.1 Pressure and Pressure Rise Rate

The standard method of calculating the peak pressure and peak pressure rise rate values and locations involves simply using the built-in LabVIEW array functions to search a pre-defined window of the pressure and pressure rise rate arrays for the maximum values and locations.

The spline method of calculating the peak pressure and peak pressure rise rate values and locations involves creating a splined waveform for each array that has ten times the resolution of the pressure array. The splined waveform arrays are searched for peak values and locations using the built-in LabVIEW array functions.

Note: The spline method is very resource intensive and should be avoided on less powerful processors.

© National Instruments. All rights reserved. 123

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.4.2 Polytropic Coefficients

The compression and expansion of the gas inside the engine cylinder can be approximated as a polytropic process.

The compression and expansion of the gas obeys the relationship , where C is a constant. Applying the relationship to several points on the compression or expansion curve allows for the calculation of the polytropic coefficient. The polytropic coefficient is uses in many other calculations, including heat release. Therefore, it is necessary to calculate the polytropic coefficient.

The polytropic coefficient, n, is derived in the following equations:

In order to calculate the polytropic coefficients of compression (PolyC) and expansion (PolyE), the associated ranges for PolyC and PolyE must be set within the 'Pressure Metrics Settings' window of the NI CAS Software Interface.

The following methods are then available for the calculation of PolyC and PolyE.

1. The 'Point-by-Point' method uses the entire ranges specified for PolyC and PolyE. Within the ranges, the equation for 'n' is solved repeatedly for each successive pair of discrete points. The collection of PolyC and PolyE results is then averaged for the reported PolyC and PolyE.

2. The 'Endpoints' method uses the start and end locations of the ranges specified for PolyC and PolyE as endpoints. In order to eliminate error caused by noise in the pressure waveform, a window around each endpoint is specified in which the values are averaged to calculate the endpoint value (2 CAD represents 2 CAD on each side of the given point). The equation for 'n' is solved using the endpoints resulting in the reported PolyC and PolyE.

3. The 'Power Fit,' or Least Squares Fit - Power Law, method uses the entire ranges specified for PolyC and PolyE.

As our function can be rearranged to match the form be used to solve for PolyC and PolyE:

, the following system of equations can where

© National Instruments. All rights reserved. 124

NI Combustion Analysis System Software for LabVIEW

User's Manual

© National Instruments. All rights reserved. 125

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.4.3 TDC Probe

The TDC probe location is a calculation taken from the waveform generated by a TDC probe sensor used during engine setup. The TDC probe location can be used to correctly phase the acquired engine data with engine position and calculated volume data. The first step in calculating the TDC probe location is determining which TDC peak in the waveform is the relevant compression TDC peak. In the case of a two-stroke engine there is only one peak.

The compression / firing TDC peak is typically the lowest of the peaks due to increased pressure in the cylinder.

Based on the selected peak, a window of the TDC probe signal surrounding the peak is selected and analyzed using one of the following methods:

1. The standard method of calculating the peak TDC probe location involves simply using the built-in LabVIEW array functions to search the pre-defined window of the TDC probe array for the maximum value location.

2. The spline method of calculating the peak TDC probe location involves creating a splined waveform for the array that has ten times the resolution of the TDC probe array. The splined waveform array is searched for peak value location using the built-in LabVIEW array functions.

3. The final method of calculating the TDC probe location, the Horizontal Cut, assumes a symmetrical profile of the

TDC probe signal. A horizontal window below the peak is selected in which numerous 'horizontal cuts' are taken.

For each cut, the crank angle, or x-axis, values at each point intercepting the waveform are taken and the midpoint is found. The collection of midpoints for each horizontal cut are averaged, resulting in the TDC probe location.

© National Instruments. All rights reserved. 126

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.5 Mean Effective Pressure

Mean effective pressure (MEP) is a value commonly used to quantify engine load, or work output, independently of engine size. All MEPs in this software are indicated values as the calculations are based on cylinder pressure. The following equation is used to calculate the various MEPs

1

: where:

W

V d i

= indicated work for a given engine revolution

= displaced cylinder volume

The indicated work, W

i

, is calculated using the following equation

1

: where:

p = cylinder pressure

dV = change in cylinder volume

Gross IMEP - Gross IMEP (IMEP g

) is calculated for each non-pumping engine revolution. A six-stroke engine, therefore, will have two independent IMEP g

values.

Pumping MEP - Pumping MEP (PMEP) is calculated for the pumping stroke, except in the case of a two-stroke engine.

Net IMEP - Net IMEP (IMEP n

) is calculated by summing the IMEP g

value(s) and the PMEP.

1. Heywood, J. B., Internal Combustion Engine Fundamentals. McGraw Hill, Inc., New York, NY. 1988.

© National Instruments. All rights reserved. 127

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.6 Motoring Pressure

The motoring pressure is modeled based on cylinder pressure, volume, valve timing, and either a constant or calculated polytropic coefficient. The pressure is modeled assuming a polytropic pressure, as in the following equation:

P starting at the point m,i-1

= P

IVC

P where: m

= motored cylinder pressure (kPa)

V = volume (m

P

IVC

3

) n = polytropic coefficient

= cylinder pressure at intake valve closing (kPa)

© National Instruments. All rights reserved. 128

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.7 Global Gas Temperature

The global (bulk) gas temperature is modeled based on cylinder pressure, volume, valve timing, intake temperature and pressure, exhaust temperature and pressure, residual gas fraction, and either a constant or calculated polytropic coefficient.

where:

T = global gas temperature

T

IVC

, P

IVC

= bulk cylinder temperature, cylinder pressure and cylinder volume at intake valve closing, , V

IVC respectively

P = cylinder pressure

V = cylinder volume

T = intake temperature i f = residual fraction

T e

= exhaust temperature

= intake pressure P i

P e

= exhaust pressure n = polytropic coefficient

1. Gatowski, J. A., Balles, E. N., Chun, K. M., Nelson, F. E., Ekchian, J. A., Heywood, J. B., 1984, “Heat Release Analysis of

Engine Pressure Data”, SAE Technical Paper Series 841359

2. Sharief, A., Chandrashekar, T. K., Antony, A. J., Samaga, B. S., 2008, “Study on Heat Transfer Correlation in IC Engines”,

SAE Technical Paper Series 2008-01-1816

© National Instruments. All rights reserved. 129

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.8 Injector

NI CAS Software uses a current or voltage measurement to determine the injection events. The user must specify the type of injector used: PFI, DI, or Piezo.

Injector Current

To measure the current drawn by the injector module, attach a current probe to the to the injector wiring.

PFI Current

© National Instruments. All rights reserved. 130

NI Combustion Analysis System Software for LabVIEW

User's Manual

DI Current

© National Instruments. All rights reserved. 131

Piezo Current

NI Combustion Analysis System Software for LabVIEW

User's Manual

© National Instruments. All rights reserved. 132

NI Combustion Analysis System Software for LabVIEW

User's Manual

Injector Voltage

Injector voltages vary from battery voltage to several hundred volts. Therefore, a protective circuit is needed to prevent the high voltage from reaching the DAQ device. The operating voltage of the injectors should be verified before connecting the injector to the DAQ device. Resistor rated above the maximum operating voltage are also required.

Please note: Most DAQ devicess and accessories have maximum voltage limits that should be followed. Please refer to your hardware documentation for details. IE. the SCB-68 has a maximum voltage of 48V listed in the user's manual.

© National Instruments. All rights reserved. 133

NI Combustion Analysis System Software for LabVIEW

User's Manual

PFI Voltage

DI Voltage

© National Instruments. All rights reserved. 134

Piezo Voltage

NI Combustion Analysis System Software for LabVIEW

User's Manual

© National Instruments. All rights reserved. 135

NI Combustion Analysis System Software for LabVIEW

User's Manual

© National Instruments. All rights reserved. 136

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.9 Heat Release

The heat release rate, or dQ/dt, represents "the difference between the chemical energy or heat released by combustion of the fuel... and the heat transfer from the system."

1

The CAS software calculates the heat release rate using several user selectable mathematical models, including:

• Single Zone

• Single Zone + Heat Transfer

• Single Zone Dual Transducer

• Single Zone Dual Transducer + Heat Transfer

• Modified Rassweiler and Withrow

• Pressure Ratio

For those models including heat transfer, the following correlations are available for selection:

• Constant

• Woschni 1967

• Woschni 1990

• Hohenberg

In the cases where heat transfer is neglected (adiabatic), the polytropic process is considered reversible and therefore isentropic. If an ideal gas is assumed, the polytropic coefficient is constant and equal to the ratio of specific heats ( = n).

2

However, when heat transfer is calculated, the following polytropic correlations are available for selection:

• Hayes

• Indolene

• Propane

• Custom

Note: Whenever heat transfer is being calculated, the 'Gas Temp' calculations must be enabled in the Calculations subhost.

1. Heywood, J. B., Internal Combustion Engine Fundamentals. McGraw Hill, Inc., New York, NY. 1988.

2. Russel, L. D., and Adebiyi, G. A., Classical Thermodynamics. Saunders College Publishing, Fort Worth, TX. 1993.

© National Instruments. All rights reserved. 137

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.9.1 Heat Release Models

© National Instruments. All rights reserved. 138

4.9.1.1 Single Zone

NI Combustion Analysis System Software for LabVIEW

User's Manual where: dQ/d = rate of heat release n = polytropic coefficient

V = cylinder volume dP/d = cylinder pressure derivative with respect to (w.r.t.) crank angle

P = cylinder pressure dV/d = cylinder volume derivative w.r.t. crank angle

1. Grimm, B. M., Johnson, R. T., 1990, “Review of Simple Heat Release Computations”, SAE Technical Paper Series 900445.

2. Cheung, H. M., Heywood, J. B., 1993, “Evaluation of a One-Zone Burn-Rate Analysis Procedure Using Production SI

Engine Pressure Data”, SAE Technical Paper Series 932749.

© National Instruments. All rights reserved. 139

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.9.1.2 Single Zone + Heat Transfer

where: dQ/d = rate of heat release

γ = ratio of specific heats, c p

/c v

V = cylinder volume dP/d = cylinder pressure derivative w.r.t. crank angle

P = cylinder pressure dV/d = cylinder volume derivative w.r.t. crank angle dQ ht

/d = heat transfer derivative w.r.t. crank angle h = heat transfer coefficient

A

T w

= cylinder wall surface area

T = cylinder global gas temperature w

= cylinder wall temperature

1. Gatowski, J. A., Balles, E. N., Chun, K. M., Nelson, F. E., Ekchian, J. A., Heywood, J. B., 1984, “Heat Release Analysis of

Engine Pressure Data”, SAE Technical Paper Series 841359.

2. Hayes, T. K., Savage, L. D., Sorenson, S. C., 1986, “Cylinder Pressure Data Acquisition and Heat Release Analysis on a

Personal Computer”, SAE Technical Paper Series 860029.

© National Instruments. All rights reserved. 140

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.9.1.3 Single Zone Dual Transducer

where: dQ/d = rate of heat release n = polytropic coefficient

V mc

= main chamber volume dP mc

/d = main chamber pressure derivative w.r.t. crank angle

V pc

= pre-chamber volume dP pc

/d = pre-chamber pressure derivative w.r.t. crank angle

P mc

= main chamber pressure dV mc

/d = main chamber volume derivative w.r.t. crank angle

1. Grimm, B. M., Johnson, R. T., 1990, “Review of Simple Heat Release Computations”, SAE Technical Paper Series 900445.

© National Instruments. All rights reserved. 141

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.9.1.4 Single Zone Dual Transducer + Heat Transfer

where: dQ/d = rate of heat release n = polytropic coefficient

V mc

= main chamber volume dP mc

/d = main chamber pressure derivative w.r.t. crank angle

V pc

= pre-chamber volume dP pc

/d = pre-chamber pressure derivative w.r.t. crank angle

P mc

= main chamber pressure dV mc dQ ht

/d = main chamber volume derivative w.r.t. crank angle

/d = heat transfer derivative w.r.t. crank angle h = heat transfer coefficient

A

T w

= cylinder wall surface area

T = cylinder global gas temperature w

= cylinder wall temperature

1. Grimm, B. M., Johnson, R. T., 1990, “Review of Simple Heat Release Computations”, SAE Technical Paper Series 900445.

2. Gatowski, J. A., Balles, E. N., Chun, K. M., Nelson, F. E., Ekchian, J. A., Heywood, J. B., 1984, “Heat Release Analysis of

Engine Pressure Data”, SAE Technical Paper Series 841359.

© National Instruments. All rights reserved. 142

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.9.1.5 Modified Rassweiler and Withrow

where: dQ/d = rate of heat release n = polytropic coefficient

V = cylinder volume dP c

/d = cylinder pressure change due to piston motion and heat release w.r.t. crank angle

P = cylinder pressure

1. Grimm, B. M., Johnson, R. T., 1990, “Review of Simple Heat Release Computations”, SAE Technical Paper Series 900445.

2. Rassweiler, G. M., Withrow, L., 1938, “Motion Pictures of Engine Flames Correlated with Pressure Cards”, Society of

Automotive Engineers, Paper 380139.

© National Instruments. All rights reserved. 143

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.9.1.6 Pressure Ratio

where: dQ/d = rate of heat release

P = cylinder pressure

P m

= motored cylinder pressure

NMEP = net (indicated) mean effective pressure

V d

= displaced cylinder volume d = crank angle differential

V = cylinder volume n = polytropic coefficient

1. Sellnau, M. C., Matekunas, F. A., Battiston, P. A., Chang, C. F., Lancaster, D. R., 2000, “Cylinder-Pressure-Based engine

Control Using Pressure-Ratio-Management and Low-Cost Non-Intrusive Cylinder Pressure Sensors”, SAE Technical Paper

Series 2000-01-0932.

© National Instruments. All rights reserved. 144

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.9.2 Heat Transfer Correlations

© National Instruments. All rights reserved. 145

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.9.2.1 Constant

This setting uses a constant user input for the heat transfer coefficient in units of W/m

2

-K.

© National Instruments. All rights reserved. 146

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.9.2.2 Woschni 1967

Gas Exchange

C

1

= 6.18

= 0 C

2

Compression

C

1

= 2.28

= 0 C

2

Combustion and Expansion

C

1

C

2

= 2.28

= 3.24 x 10

-3 where: h = heat transfer coefficient (W/m

2

-K)

N = engine speed (RPM)

B = cylinder bore (m)

P = cylinder pressure (kPa)

T = cylinder global gas temperature (K) w = mean cylinder gas velocity (m/s)

Sp = mean piston speed (m/s)

V

D

= displacement per cylinder (m

3

)

V = cylinder volume (m

3

P m

)

= motored cylinder pressure (kPa) n = polytropic coefficient

T

IVC

, P

IVC

, V respectively

IVC

= bulk cylinder temperature, cylinder pressure and cylinder volume at intake valve closing,

1. Heywood, J. B., Internal Combustion Engine Fundamentals. McGraw Hill, Inc., New York, NY. 1988.

2. Woschni, G., 1967, “A Universally Applicable Equation for the Instantaneous Heat Transfer Coefficient in the Internal

Combustion Engine”, Society of Automotive Engineers, Paper 670931.

© National Instruments. All rights reserved. 147

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.9.2.3 Woschni 1990

This modified version of Woschni's correlation

1,2

takes part load operating conditions into account

3

: when where: w = mean cylinder gas velocity (m/s)

Sp = mean piston speed (m/s)

V

TDC

= cylinder clearance (squish) volume (m

3

)

T

IVC

, P

IVC

, V

IVC

= cylinder global gas temperature, cylinder pressure and cylinder volume at intake valve closing, respectively

IMEP = indicated mean effective pressure (kPa)

V

D

= displacement per cylinder (m

3

)

P = cylinder pressure (kPa)

P m

= motored cylinder pressure (kPa)

1. Woschni, G., 1967, “A Universally Applicable Equation for the Instantaneous Heat Transfer Coefficient in the Internal

Combustion Engine”, Society of Automotive Engineers, Paper 670931.

2. Sihling, K., Woschni, G., 1979, “Experimental Investigation of the Instantaneous Heat Transfer in the Cylinder of a High

Speed Diesel Engine”, Society of Automotive Engineers, Inc., Paper 790833.

3. Huber, K., Woschni, G., and Zeilinger, K., 1990, "Investigations on Heat Transfer in Internal Combustion Engines Under

Low Load and Motoring Conditions," Society of Automotive Engineers, Inc., Paper 905018.

© National Instruments. All rights reserved. 148

4.9.2.4 Hohenberg

NI Combustion Analysis System Software for LabVIEW

User's Manual where: h = heat transfer coefficient (W/m

2

-K)

N = engine speed (RPM)

V = cylinder volume (m

3

)

P = cylinder pressure (kPa)

T = cylinder global gas temperature (K)

Sp = mean piston speed (m/s)

1. Hohenberg, G. F., 1979, “Advanced Approaches for Heat Transfer Calculations”, Society of Automotive Engineers, Inc.,

Paper 790825.

© National Instruments. All rights reserved. 149

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.9.3 Polytropic Correlation

© National Instruments. All rights reserved. 150

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.9.3.1 Hayes (SAE860029)

where:

γ = ratio of specific heats

T = cylinder global gas temperature (K) c = specific heat for constant pressure p

R = the universal gas constant

1. Hayes, T. K., Savage, L. D., Sorenson, S. C., 1986, “Cylinder Pressure Data Acquisition and Heat Release Analysis on a

Personal Computer”, SAE Technical Paper Series 860029

© National Instruments. All rights reserved. 151

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.9.3.2 Indolene (SAE841359)

where:

γ = ratio of specific heats

T = cylinder global gas temperature (K)

1. Gatowski, J. A., Balles, E. N., Chun, K. M., Nelson, F. E., Ekchian, J. A., Heywood, J. B., 1984, “Heat Release Analysis of

Engine Pressure Data”, SAE Technical Paper Series 841359

© National Instruments. All rights reserved. 152

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.9.3.3 Propane (SAE841359)

where:

γ = ratio of specific heats

T = cylinder global gas temperature (K)

1. Gatowski, J. A., Balles, E. N., Chun, K. M., Nelson, F. E., Ekchian, J. A., Heywood, J. B., 1984, “Heat Release Analysis of

Engine Pressure Data”, SAE Technical Paper Series 841359

© National Instruments. All rights reserved. 153

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.9.3.4 Custom

The custom option for the polytropic correlation allows the user to input values for coefficients a and b to be used in the following linear correlation: where:

γ = ratio of specific heats

T = cylinder global gas temperature (K)

© National Instruments. All rights reserved. 154

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.9.4 Start and End of Combustion

A precise definition of the start of combustion (SOC) and end of combustion (EOC) is required for accurate calculation of the mass fraction burned (MFB) crank angle locations. The SOC and EOC are used to define a window over which the cumulative heat release is calculated from the heat release rate (HRR) waveform. The following methods are used to define these locations:

Start of combustion (SOC)

1. Constant - Defines a constant crank angle (DATDC) as the SOC.

2. N Below Zero - Sets a crank angle (DATDC) to begin looking for a negative zero crossing in the HRR waveform.

After 'N' points are found past the negative zero crossing, the crossing is confirmed to be the SOC.

3. Boxcar N Below Zero - Same definition of 'N Below Zero', except that a Boxcar filter of window 'N' is applied to the HRR waveform. Also, rather than using 'N' points to confirm the crossing, the first negative zero crossing is taken as the SOC.

4. N Above Zero - Sets a crank angle (DATDC) to begin looking for the last positive zero crossing in the HRR waveform. After 'N' points are found past the positive zero crossing, the crossing is confirmed to be the SOC.

5. Boxcar N Above Zero - Same definition of 'N Above Zero', except that a Boxcar filter of window 'N' is applied to the HRR waveform. Also, rather than using 'N' points to confirm the crossing, the first positive zero crossing is taken as the SOC.

The following figure represents both the 'N Below Zero' and 'N Above Zero' conditions for calculating the SOC, where 1 < N < 6.

End of combustion (EOC)

© National Instruments. All rights reserved. 155

NI Combustion Analysis System Software for LabVIEW

User's Manual

1. Constant - Defines a constant crank angle (DATDC) as the EOC

2. N Below Zero - Sets a crank angle (DATDC) to end looking for the first negative zero crossing in the HRR waveform. After 'N' points are found past the negative zero crossing, the crossing is confirmed to be the EOC.

If a negative zero crossing is not found, the 'End Angle' will be used as the EOC.

3. Boxcar N Below Zero - Same definition of 'N Below Zero', except that a Boxcar filter of window 'N' is applied to the HRR waveform. Also, rather than using 'N' points to confirm the crossing, the first negative zero crossing is taken as the SOC.

© National Instruments. All rights reserved. 156

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.10 Combustion Noise

Combustion noise is calculated based on the power level (dB) from the cylinder pressure waveform using the following steps:

1. Converting the cylinder pressure waveform from the engine-position domain to the time domain

2. Converting the cylinder pressure signal from the time domain to the frequency domain using Fast Fourier

Transform (FFT)

3. Converting the cylinder pressure frequency domain into a third-octave spectrum to simulate analog devices

4. Filter the spectrum for human auditory attenuation using the A-weighting curve

2

and for engine structure attenuation using the SA1-7dB

3,4

curve (Lucas plot).

1. Scarpati, J., Wikstrom, A., Jonsson, O., Glav, R., Handel, P., and Hjalmarsson, H., 2007, "Predication of Engine Noise using Parameterized Combustion Pressure Curves", SAE Technical Paper Series 2007-01-2373.

2. International Electrotechnical Commission, "Electroacoustics - Sound level meters," IEC 61672, 2003.

3. Herbert, A., and Russell, M., 1982, "Measurement of Combustion Noise in Diesel Engines", Mechanical Engineering

Technology.

4. Reinhart, T., 1987, "An Evaluation of the Lucas Combustion Noise Meter on Cummins 'B' Series Engines", SAE Technical

Paper Series 870952.

© National Instruments. All rights reserved. 157

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.11 Misfire

The misfire calculation returns a Boolean output (0 or 1). The calculation is based on one of the following misfire threshold (kPa) comparisons:

1. Peak Pressure < Misfire Threshold

2. Net Mean Effective Pressure = NMEP < Misfire Threshold

3. Combustion Pressure = Cylinder Pressure - Motored Cylinder Pressure < Misfire Threshold

© National Instruments. All rights reserved. 158

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.12 Cam

NI CAS Software uses a digital signal with rising and falling edges to determine the cam phasing. The user must specify the edge count, location (CAD), and whether each edge is rising or falling. The user specified pattern is compared with the actual pattern to determine the cam advance or retard. The user specified position is usually the default cam position or the position where the cam returns without power.

© National Instruments. All rights reserved. 159

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.13 Synchronous Pump

NI CAS Software uses a digital signal with rising and falling edges to determine the start, end, and duration of multiple pulses over the span of one engine cycle. The number of pulses is reported along with the start, end, and duration for each pulse.

© National Instruments. All rights reserved. 160

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.14 PWM

NI CAS Software uses a digital signal with rising and falling edges to determine the frequency and duty cycle of a

PWM signal. The frequency is calculated using the rising edges of the signal. The duty cycle is calculated using the ratio of signal high time compared to the time between rising edges. The cycle results are averaged over the entire cycle.

Note: The sample rate of the system must be much greater than the PWM frequency to get accurate results.

© National Instruments. All rights reserved. 161

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.15 Knock

NI CAS Software uses the Bandpass, Rectify, Integrate, Compare (BRIC) knock detection method. This method requires the user to define calibration windows where there is little electrical and mechanical noise. The user also must provide cutoff frequencies for the bandpass filter (2nd order Butterworth IIR), which allow the fundamental frequencies of knock to pass but not background noise. The last required user input is the threshold where the raw knock intensity is considered to be knock.

© National Instruments. All rights reserved. 162

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.16 Spark

NI CAS Software uses a current or voltage on the low side of primary ignition coil to measure the spark event and spark dwell.

Spark Current

To measure the current drawn by the spark module, attach a current probe to the low side of the primary ignition coil.

The signal should be similar to the following.

© National Instruments. All rights reserved. 163

NI Combustion Analysis System Software for LabVIEW

User's Manual

Spark Voltage

The low side of the primary ignition coil can reach 400V. Therefore, a protective circuit is needed to prevent the high voltage from reaching the DAQ device. A zener diode with a breakdown voltage of 1/2 the maximum analog input voltage is required (10V ADC = ~5V zener diode). A resistor rated above 400V is also required. It should be sized to limit the current flow to the zener diode (100 k and 1/4 W).

Please note: Most DAQ devices and accessories have maximum voltage limits that should be followed. Please refer to your hardware documentation for details. IE. the SCB-68 has a maximum voltage of 48V listed in the user's manual.

© National Instruments. All rights reserved. 164

NI Combustion Analysis System Software for LabVIEW

User's Manual

The signal should be similar to the following.

© National Instruments. All rights reserved. 165

NI Combustion Analysis System Software for LabVIEW

User's Manual

© National Instruments. All rights reserved. 166

NI Combustion Analysis System Software for LabVIEW

User's Manual

4.17 Custom User VIs

While NI CAS Software incorporates many well known calculations and processing operations useful for combustion analysis, inevitably each project is different and may require calculations not included in NI CAS Software by default.

To accommodate this, NI CAS Software has the ability to execute custom user programmed VIs in three different locations: processing, heat release, and calculations. Processing algorithms are intended to manipulate waveforms, e.g., cylinder pressure pegging, before other calculations are performed. Custom heat release allows the user to designate a non-standard model for heat release. Finally, the outputs of user calculations are scalar values for which statistics are automatically calculated.

User Templates

In order to ensure successful integration of a custom user VI, user VI templates must be used as a starting point for all custom user VIs. User VI templates are included with the installation of NI CAS Software in the example project as well as the following location in the LabVIEW directory:

\...\examples\Combustion Analysis\

Note: The LabVIEW development environment is required to create a custom user VI

Custom Application: Cumulative Heat Release

In this application, the user desires to calculate the cumulative heat release in Joules for one cycle of combustion.

Mathematically, this is done by integrating calculated heat release rate (dQ/dθ) between the defined start of combustion (SOC) and end of combustion (EOC), as in the following equation:

The following steps were accomplished to achieve this goal:

1. Open the template for custom user calculations in the Combustion Analysis examples folder. The block diagram should appear as follows:

© National Instruments. All rights reserved. 167

NI Combustion Analysis System Software for LabVIEW

User's Manual

User Calculations Template

2. Use the 'Unbundle by Name' function from the 'Cluster, Class, & Variant' function palette to unpack the following inputs:

• Cycle Waveforms \ Heat Release Rate [J/CAD]

• All Setup \ Engine Geometry Setup \ Rotations Per Cycle

• Engine Geometry Results \ Sample Resolution [ppr]

Unbundling calculation inputs

3. Create start and end of combustion constants in degrees after top dead center (DATDC), then convert them to array indices using the 'Rotations Per Cycle' and 'Sample Resolution' inputs.

© National Instruments. All rights reserved. 168

NI Combustion Analysis System Software for LabVIEW

User's Manual

Defining and converting SOC and EOC to indices

Note: Waveform array indices start with '0' at 180 (2-stroke) or 360 CAD (4+ stroke) before compression TDC. For example, with a 3600 pulse-per-revolution encoder on a 4-stroke engine, the indices will range from 0 to 7200, with

3600 being compression TDC.

4. Index an array subset from the heat release rate waveform, starting with the SOC and ending at the EOC (with duration EOC-SOC). This array subset corresponds to the period during which combustion is occuring. Using a For

Loop, this discrete subset can be integrated using shift register terminals and an add block. The result is the scalar value for cumulative heat release in Joules.

Indexing the heat release waveform and calculating the integral

5. Pack the scalar result and value name into a cluster using the 'Bundle by Name' function block and typedef provided. Convert the bundle to an array of bundles and connect this to the 'User Results' indicator.

© National Instruments. All rights reserved. 169

NI Combustion Analysis System Software for LabVIEW

User's Manual

Packing outputs into an array of bundles

6. Use the 'Save As...' function to save your VI as a copy, renaming the new variant so that the template is not overwritten. Finally, select your VI in the 'Calculations' subhost of NI CAS Software and view the result in the 'User' table.

Selecting and enabling User Calculations

© National Instruments. All rights reserved. 170

Viewing User results

NI Combustion Analysis System Software for LabVIEW

User's Manual

© National Instruments. All rights reserved. 171

5. Post Processing

NI Combustion Analysis System Software for LabVIEW

User's Manual

© National Instruments. All rights reserved. 172

NI Combustion Analysis System Software for LabVIEW

User's Manual

5.1 NI CAS Software File Structure

Groups-Channels

Volume

• Crank Angle

• Volume

• dVolume

• Cylinder Area

User Properties

File Settings

Basic Settings

Cam Settings

• 0...15

Filter Settings

• 0...15

Engine Geometry Setup

Synchronous

• Time

• AI0...15

• TDC

• Data

• Reduced Resolution

• Reserved

• DI4...15

• DI Data

Heat Release Settings

Injection Settings

Knock Settings

• 0...15

Misfire Settings

Pegging Settings

Gas Temperature Settings

Separate Settings

TDC Offset Settings

Asynchronous

• Time

C

C

C

C

C

R-C-O

R

C

C

C

C

C

C

C-N

R

C

C-O

C

R-S-C-O

C

C

R

R-C-N

Use

R-S

R-S

C

C

C

C-O

R-S

R-S

R-S

C

Description

Pre-calculated volume related waveforms

Cycle crank angle

Cycle volume

Cycle volume derivative

Cycle cylinder area

User specified properties

File settings

Basic settings

Cam settings

Cam settings for each cylinder

Filter settings

Filter settings for each filter

Engine geometry setup

Engine synchronous data

Sample timestamp

Synchronous channel

Digital channel setup

Digital channel setup

Digital channel setup

Digital channel setup

Digital channel setup

Digital channel data in bit field

Heat release Settings

Injection Settings

Knock Settings

Knock settings for each cylinder

Misfire settings

Pegging settings

Gas temperature settings

Separate settings

TDC offset settings

Asynchronous data

Sample timestamp

© National Instruments. All rights reserved. 173

• AI0...15

• TDC

• Data

• Reduced Resolution

• Reserved

• DI4...15

• DI Data

Medium Speed

• Time

• AI0...

FPGA

• Time

• ID

• Data

• AI0...

User Setup

Cycle

• Time

• Speed

• Cycle

Slow Speed

• Time

• AI0...

Array Data - 1...

• Crank Angle

• AI0... - 0...

Synchronous Waveforms - 1...

• Crank Angle

• AI0...

Asynchronous Waveforms - 1...

• Crank Angle

• AI0...

Calculation Waveforms - 1...

S

S

S-O

S

S-N

S-O

S

S-N

S-O

R

R

R-C-N

C

R

R

R-C-O

R

R-C

S-O

R

R-C-O

R

R-C-N

R

R

R-C-O

R

C

C

R-C-N

C

C

C-N

NI Combustion Analysis System Software for LabVIEW

User's Manual

Synchronous channel

Digital channel setup

Digital channel setup

Digital channel setup

Digital channel setup

Digital channel setup

Digital channel data in bit field

Medium speed data

Sample timestamp

Medium speed channel

FPGA data

Sample timestamp

Sample ID

Sample Data

FPGA channels

User defined calculation setup

Cycle properties

Cycle start timestamp

Previous cycle speed

Cycle number

Slow speed data

Sample timestamp

Slow speed channel

Post process cycle-by-cycle waveforms for each cylinder

Cycle crank angle

Cycle-by-cycle data

Engine synchronous ensemble averages for each cylinder

Cycle crank angle

Ensemble average waveform

Asynchronous ensemble averages for each cylinder

Cycle crank angle

Ensemble average waveform

Calculated ensemble averages for each cylinder

© National Instruments. All rights reserved. 174

• Crank Angle

• AI0...

Calculation Results - 1...

• AI0..

R = Raw Data

S = Summary Data

C = Configuration Properties

O = Optional

N = Names Vary

S

S-N

S

S-N

NI Combustion Analysis System Software for LabVIEW

User's Manual

Cycle crank angle

Ensemble average waveform

Calculated results for each cylinder

Calculated values

© National Instruments. All rights reserved. 175

NI Combustion Analysis System Software for LabVIEW

User's Manual

5.2 Summary Files

Summary files contain all the calculated results and ensemble averages for all the waveforms.

Opening Summary Data Files

1. Determine the file version and if it is a raw or summary file.

2. Read configuration data.

a. General settings are found at the group level.

b. Channel settings are found at the channel level.

3. Read ensemble averages for desired cylinder

4. Read calculated results for desired cylinder

© National Instruments. All rights reserved. 176

NI Combustion Analysis System Software for LabVIEW

User's Manual

5.3 Raw Files

NI CAS Software includes several SubVIs to handle all the raw opening and processing. These subVIs are are part of an example application that can be used to view raw data files. Please note that the raw data files start at an arbitrary crank angle and must be aligned using data encoded in the file. The files store data as it is read from the device. Therefore, the individual cylinder offsets must also be accounted for. In the figure below, cycle X is the first available cycle. LabVIEW VIs and examples have been provided to allow easy access to the cycle by cycle data without any need to know the specifics of the encoded data. Please note that the data in the files is stored as voltages and must be scaled and pegged (when appropriate) to be useful.

Opening Raw Data Files

1. Determine the file version and if it is a raw or summary file.

2. Read configuration data.

a. General settings are found at the group level.

b. Channel settings are found at the channel level.

3. Determine the TDC offsets a. Use the first bit of "DI Data" ("TDC") to get the global TDC offset.

b. Use "Engine Geometry Setup" properties to determine resolution and cylinder TDC offsets.

c. Use the third bit of "DI Data" ("Reduced Resolution") to reconstruct asynchronous data.

4. Decode "Data" to determine cycle speed, time, and cycle number.

5. Use engine synchronous or asynchronous timestamps to reconstruct FPGA and medium speed data.

6. Separate different types of data for each cylinder.

7. Apply channel gains and offsets to get to engineering units.

8. Apply calculations to get results.

Raw File Viewer

© National Instruments. All rights reserved. 177

1. Make sure the Activation indicator is green.

2. Select a raw file to open.

3. Slide the cycle selector to the desired cycle.

4. Select a cylinder to display.

5. Select the appropriate tab to view and change settings.

NI Combustion Analysis System Software for LabVIEW

User's Manual

© National Instruments. All rights reserved. 178

NI Combustion Analysis System Software for LabVIEW

User's Manual

5.4 TDMS Files

Opening TDMS Files in Microsoft Excel

National Instruments provides a free Microsoft Excel plug-in that imports TDMS files. Importing a file creates a multi-page spreadsheet with all the data stored in the file. The first page contains a summary of all the groups and channels. Each group has a page where each column is a channel of data. Please note that Microsoft Excel 2003 is limited to 256 columns and 65536 rows. Therefore, the custom properties (displayed in the first 2 rows on the main page) which contain all the calculation configuration information may need to be turned off. Raw data channels may also be too long and will be truncated.

Opening TDMS Files in DIAdem

DIAdem is a power full tool for viewing, analyzing, and presenting data. When DIAdem is installed, double clicking on a tdms file will open it in DIAdem.

© National Instruments. All rights reserved. 179

NI Combustion Analysis System Software for LabVIEW

User's Manual

Converting TDMS Files to Other Formats

TDMS files can be converted to other formats and opened in a variety of interfaces. Many resources are available on at http://www.ni.com/ . The NI CAS Software comes with an application to convert a group or folder of files from the

TDMS format to text files. Due to the change in how data is being stored, text files will take ~10 times the disk space

as the TDMS files. See Batch Processing for more details.

© National Instruments. All rights reserved. 180

NI Combustion Analysis System Software for LabVIEW

User's Manual

5.5 Batch Processing

Batch Process Raw Files to Summary files

NI CAS Software contains an application to process raw files to summary files. The application can process up to 8 files in parallel. The user selects a source folder and the desired files to process. The summary files are placed in the specified folder.

Batch Process TDMS files to Text files

NI CAS Software contains an application to process TDMS files to text files. The application can process up to 8 files in parallel. The user selects a source folder and the desired files to process. The summary files are placed in the specified folder.

© National Instruments. All rights reserved. 181

NI Combustion Analysis System Software for LabVIEW

User's Manual

© National Instruments. All rights reserved. 182

NI Combustion Analysis System Software for LabVIEW

User's Manual

6. Troubleshooting

A Microsoft Windows Help file (.chm) for NI CAS Software is provided with the software download. Each window within the user interface contains a Help “?” button in the bottom right corner. Pressing this button will open the Help file to the associated help topic page.

Frequently Asked Questions (FAQs)

Q: I get an error message when I try to activate the software. What do I do?

A: Refer to the

Software Activation section.

Q: How do I add my own calculations or results to the NI CAS Software?

A: NI CAS Software provides the ability to easily integrate user calculations in three areas; Processing, Heat-

Release Rate, and Calculations.

1.

Processing: All of the results of the processing steps (alignment, scaling, pegging, separation) are provided to the user calculations which can manipulate the waveform and other information before all of the calculations get the information.

2.

Heat Release Rate: All of the results from the processing steps are provided to the user calculations which need to generate a heat release rate waveform. The resulting waveform is then used to calculate mass fraction burned and other heat release related parameters.

3.

Calculations: All of the results from the processing steps and calculation steps are provided to the user calculations. The user calculations provide an array of calculated results to the NI CAS Software for display and saving in summary files.

NI CAS Software applications contain the ability to stream custom data from other parts of the application.

FPGA Data originates in the FPGA. Each parameter needs to be assigned an ID. All FPGA data streams to raw data files. Only data with ID defined in the FPGA Setup are processed in real-time and saved in summary files.

Slow Speed Data is read no more than once per cycle and is saved in raw and summary data files. The top level NI CAS Software example contains a template showing how to write the data. The data enters NI CAS

Software through a global variable where the user defines the name, units, and value for each item.

User Properties can be added to raw and summary files. This data is captured at the beginning of a file and only written once. NI CAS Software example applications write all CalPoints to the properties by default.

Q: How do I add a miscellaneous sensor waveform to my display?

A: To display and save any signal, simply add it to the measurement setup and associate it with the appropriate cylinder. It will be displayed with all the AI or DI data for that cylinder.

When do I need to align the TDC offset?

A: The TDC offset must be aligned any time the encoder position is modified. This includes changing the encoder.

A: The TDC offset will change as a result of changing the encoder setup parameters. These parameters may have a small effect on the relation of TDC to the encoder Z pulse. Please see the section above for more details.

A: The TDC offset will change as a result of changing the encoder resolution, even if the Z pulse remains constant.

© National Instruments. All rights reserved. 183

NI Combustion Analysis System Software for LabVIEW

User's Manual

Q: How do I save the current configuration?

A: To save the current NI CAS Software settings, use the NI SCM “Save Current Calibration as Default” (purple) or the “Save Calibration As…” (blue) buttons on the SCM interface. This saves a file to the LabVIEW default data directory. (This is typically under “.\My Documents\LabVIEW Data” for Microsoft Windows and "C:\ni-rt\LabVIEW

Data" for Real-Time.) Calibration files have a .cdl extension. These options can be found under the "Calibration" menu.

Q: How do I load a saved configuration?

A: To load a previous NI CAS Software calibration, copy the desired calibration file into the LabVIEW default data directory. (This is typically under “.\My Documents\LabVIEW Data” for Microsoft Windows and "C:\ni-rt\LabVIEW

Data" for Real-Time.) Use the "Calibration > Load Calibration" if live loading is enabled. Use the "Calibration > Set

Calibration" and restart the NI CAS Software target if live loading is disabled. Restart the NI CAS Software target application and select the appropriate file is the calibration selector is enabled. See the NI SCM User's Manual for more details.

Q: Why does Microsoft Excel fail to open a TDMS files?

A: The TDMS Microsoft Excel plug-in opens each property in a new column across the top of the spreadsheet.

Property fields are used to store all (>255) of the configuration parameters. However, Microsoft Excel 2003 is limited to 255 columns. Open the TDMS plug-in properties and turn off custom property imports.

Q: How do I customize the user interface?

A: The user interface is a standard LabVIEW VI. It may be modified with LabVIEW development tools to meet user requirements. The file should be saved in a new location so that updating NI CAS Software installation does not overwrite the changes.

A: See the NI SCM User's Manual.

Q: What font is used in the example applications?

A: The example applications use Segoe UI size 15 pt as the default font. In some circumstances, a different size is used.

Q: Why am I getting DAQ errors?

A: Make sure that the hardware is set up properly in the Measurements and Automation Explorer and that the

Measurement Setup tab has the proper physical channel names.

A: Verify that the device is not being used for other DAQ tasks.

A: Verify that a single DAQ device in not used for synchronous and asynchronous measurements.

Q: Why is the top of the pressure signal clipped (flat)?

A: The signals will appear flat when the charge amplifier is outputting a value greater than the DAQ device or the charge amplifier output is at its maximum.

A: Reset the charge amplifier to set the zero offset pressure.

A: Adjust the output gain of the charge amplifier.

Q: What do I do if I am having trouble obtaining encoder sync?

© National Instruments. All rights reserved. 184

NI Combustion Analysis System Software for LabVIEW

User's Manual

A: Verify that the Cam/Crank/TDC signals are set up correctly (polarity, offsets, etc.)

A: The TDC signal and the crank signals should not have rising edges at the same time. This condition can cause a situation where the TDC signal and the crank signals toggle position and cause an error. (One signal may be read as true before the other.)

A: Verify that the proper signals are connected to the FPGA. It may be helpful to pass the encoder signals through the FPGA and read them use an oscilloscope if available.

A: The encoder synchronization is controlled by the engine tracking VIs. Please refer to the EPT documentation for details on the specific flags and inputs.

Q: Why are the buffers or queues overflowing?

A: The buffers fill when the computer system hardware is not able to keep up with the program demands. A combination of faster CPU, faster hard drive or additional RAM will alleviate the problem.

A: The performance of the system depends on many variables including user defined functions. It may be necessary to remove some real time processing to achieve the desired performance.

Q: Why are the speed and the timer not working correctly?

A: Check the PFI to P0 jumpers described in the hardware setup information. That data is transferred over these jumpers.

Q: Why is the NI CAS Software running but are doing nothing?

A: Please verify that you have activated the NI CAS Software. Please see Installation and Activation

for details.

Q: Why doesn't the Deployment Version of NI CAS Software start correctly?

A: Verify that the appropriate version of DAQmx and LabVIEW Runtime are installed. The installers are available on National Instruments website and listed at the beginning of this manual.

A: Verify that NI SCM is installed and activated. Please see the NI SCM user’s manual for details on installation and activation of NI SCM.

A: Verify that NI CAS Software for Deployment is activated. Check the Deployment Target Program front panel to verify that it is activated correctly.

A: Manually start the application. Please see the SCM user’s manual for more details.

1. Launch the NI CAS Software for Deployment Target Program. It cam be started from LabVIEW, select

Help > Find Examples. Search for "CAS".

2. Open NI SCM

3. Within NI SCM, define the Target IP address as “127.0.01” or your computer IP address.

4. Within NI SCM, set the Host VI to “<Program Files>\National Instruments\CAS 2014\Host\CAS

Runtime.vi”.

5. Within NI SCM, set the pairing file to “<Program Files>\National Instruments\CAS 2014\Host\CAS

Runtime.par”.

6. Within NI SCM, start the Host VI.

Q: Why does the real time controller crashed without warning?

A: Reboot the controller and try running the application again.

A: It may be possible to exceed the total physical memory of real time system. In this case, the real time controller will most likely crash (real time systems do not have virtual memory). The memory should be monitored using one of

© National Instruments. All rights reserved. 185

NI Combustion Analysis System Software for LabVIEW

User's Manual the tools available with LabVIEW. Remove some of the memory use or add more memory to the system to prevent the crashes. (Please check with National Instruments for details on upgrading memory in a real time system.)

© National Instruments. All rights reserved. 186

GMEP

IMEP kB kHz

MAX

MEP

MFB

MB

MHz

NI

NMEP

OS

PFI

PFI

PMEP

PR

PCI

PXI

RIO

API

CPU

DAQ

DI dV

EPT

FFT

FPGA

HRR

Hz

Async

ATDC

BRIC

BTDC

CAD

CAS cDAQ

7. Abbreviations

Application Interface

Asynchronous (sampled at specific time intervals)

Crank Angle Degrees After Top Dead Center

Bandpass, Rectify, Integrate, and Compare

Crank Angle Degrees Before Top Dead Center

Crank Angle Degrees

Combustion Analysis System

Compact DAQ device

Central Processing Unit

Data Acquisition

Direct Injection

Differential Volume

Engine Position Tracking

Fast Fourier Transform

Field Programmable Gate Array

Heat Release Rate

Hertz (sec

-1)

Gross Mean Effective Pressure

Gross Mean Effective Pressure

Kilobyte

Kilohertz (10

3

sec-

1

)

Measurements and Automation Explorer

Mean Effective Pressure

Mass Fraction Burned

Megabyte

Megahertz (10

6

sec-

1

)

National Instruments

Net Mean Effective Pressure

Operating System

Peripheral Input (DAQ)

Port Fuel Injector

Pumping Mean Effective Pressure

Pressure Ratio

Peripheral Component Interconnect

PCI eXtensions for Instrumentation

Reconfigurable I/O

NI Combustion Analysis System Software for LabVIEW

User's Manual

© National Instruments. All rights reserved. 187

RT

SCM

TDC

Sum

Sync

V

VI

Real Time

Software Calbiration Management Toolkit

Top Dead Center

Summary

Synchronous (sampled at specific CAD)

Volume

Virtual Instrument

NI Combustion Analysis System Software for LabVIEW

User's Manual

© National Instruments. All rights reserved. 188

NI Combustion Analysis System Software for LabVIEW

User's Manual

8. Additional Support/Feedback

Contact your local NI branch office for support details or visit http://www.ni.com/support/

For additional help with getting your NI hardware and software installed and configured, visit: http://www.ni.com/ gettingstarted/

© National Instruments. All rights reserved. 189

NI Combustion Analysis System Software for LabVIEW

User's Manual

9. Important Information

© National Instruments. All rights reserved. 190

NI Combustion Analysis System Software for LabVIEW

User's Manual

9.1 Warranty

Remove the following paragraph for software products.

NI CAS Software is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. This warranty includes parts and labor.

The media on which you receive National Instruments software are warranted not to fail to execute programming instructions, due to defects in materials and workmanship, for a period of 90 days from date of shipment, as evidenced by receipts or other documentation. National Instruments will, at its option, repair or replace software media that do not execute programming instructions if National Instruments receives notice of such defects during the warranty period. National Instruments does not warrant that the operation of the software shall be uninterrupted or error free.

A Return Material Authorization (RMA) number must be obtained from the factory and clearly marked on the outside of the package before any equipment will be accepted for warranty work. National Instruments will pay the shipping costs of returning to the owner parts which are covered by warranty.

National Instruments believes that the information in this document is accurate. The document has been carefully reviewed for technical accuracy. In the event that technical or typographical errors exist, National Instruments reserves the right to make changes to subsequent editions of this document without prior notice to holders of this edition. The reader should consult National Instruments if errors are suspected. In no event shall National

Instruments be liable for any damages arising out of or related to this document or the information contained in it.

EXCEPT AS SPECIFIED HEREIN, NATIONAL INSTRUMENTS MAKES NO WARRANTIES, EXPRESS

OR IMPLIED, AND SPECIFICALLY DISCLAIMS ANY WARRANTY OF MERCHANTABILITY OR FITNESS

FOR A PARTICULAR PURPOSE. CUSTOMER'S RIGHT TO RECOVER DAMAGES CAUSED BY FAULT

OR NEGLIGENCE ON THE PART OF NATIONAL INSTRUMENTS SHALL BE LIMITED TO THE AMOUNT

THERETOFORE PAID BY THE CUSTOMER. NATIONAL INSTRUMENTS WILL NOT BE LIABLE FOR DAMAGES

RESULTING FROM LOSS OF DATA, PROFITS, USE OF PRODUCTS, OR INCIDENTAL OR CONSEQUENTIAL

DAMAGES, EVEN IF ADVISED OF THE POSSIBILITY THEREOF. This limitation of the liability of National

Instruments will apply regardless of the form of action, whether in contract or tort, including negligence. Any action against National Instruments must be brought within one year after the cause of action accrues. National Instruments shall not be liable for any delay in performance due to causes beyond its reasonable control. The warranty provided herein does not cover damages, defects, malfunctions, or service failures caused by owner's failure to follow the

National Instruments installation, operation, or maintenance instructions; owner's modification of the product; owner's abuse, misuse, or negligent acts; and power failure or surges, fire, flood, accident, actions of third parties, or other events outside reasonable control.

© National Instruments. All rights reserved. 191

NI Combustion Analysis System Software for LabVIEW

User's Manual

9.2 Copyright

Under the copyright laws, this publication may not be reproduced or transmitted in any form, electronic or mechanical, including photocopying, recording, storing in an information retrieval system, or translating, in whole or in part, without the prior written consent of National Instruments Corporation.

National Instruments respects the intellectual property of others, and we ask our users to do the same. NI software is protected by copyright and other intellectual property laws. Where NI software may be used to reproduce software or other materials belonging to others, you may use NI software only to reproduce materials that you may reproduce in accordance with the terms of any applicable license or other legal restriction.

End-User License Agreements and Third-Party Legal Notices

You can find end-user license agreements (EULAs) and third-party legal notices in the following locations:

Notices are located in the <National Instruments>\_Legal Information and <National Instruments> directories.

EULAs are located in the <National Instruments>\Shared\MDF\Legal\license directory.

Review <National Instruments>\_Legal Information.txt for information on including legal information in installers built with NI products.

© National Instruments. All rights reserved. 192

NI Combustion Analysis System Software for LabVIEW

User's Manual

9.3 Trademarks

Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for more information on National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent

Notice at ni.com/patents . You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at ni.com/legal/exportcompliance for the National Instruments global trade compliance policy and how to obtain relevant HTS codes,

ECCNs, and other import/export data.

© National Instruments. All rights reserved. 193

NI Combustion Analysis System Software for LabVIEW

User's Manual

9.4 Patents

For patents covering the National Instruments products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents .

© National Instruments. All rights reserved. 194

NI Combustion Analysis System Software for LabVIEW

User's Manual

9.5 Warning Regarding Use of NI Products

WARNING REGARDING USE OF NATIONAL INSTRUMENTS PRODUCTS

(1) NATIONAL INSTRUMENTS PRODUCTS ARE NOT DESIGNED WITH COMPONENTS AND TESTING FOR

A LEVEL OF RELIABILITY SUITABLE FOR USE IN OR IN CONNECTION WITH SURGICAL IMPLANTS OR

AS CRITICAL COMPONENTS IN ANY LIFE SUPPORT SYSTEMS WHOSE FAILURE TO PERFORM CAN

REASONABLY BE EXPECTED TO CAUSE SIGNIFICANT INJURY TO A HUMAN.

(2) IN ANY APPLICATION, INCLUDING THE ABOVE, RELIABILITY OF OPERATION OF THE SOFTWARE

PRODUCTS CAN BE IMPAIRED BY ADVERSE FACTORS, INCLUDING BUT NOT LIMITED TO FLUCTUATIONS

IN ELECTRICAL POWER SUPPLY, COMPUTER HARDWARE MALFUNCTIONS, COMPUTER OPERATING

SYSTEM SOFTWARE FITNESS, FITNESS OF COMPILERS AND DEVELOPMENT SOFTWARE USED TO

DEVELOP AN APPLICATION, INSTALLATION ERRORS, SOFTWARE AND HARDWARE COMPATIBILITY

PROBLEMS, MALFUNCTIONS OR FAILURES OF ELECTRONIC MONITORING OR CONTROL DEVICES,

TRANSIENT FAILURES OF ELECTRONIC SYSTEMS (HARDWARE AND/OR SOFTWARE), UNANTICIPATED

USES OR MISUSES, OR ERRORS ON THE PART OF THE USER OR APPLICATIONS DESIGNER (ADVERSE

FACTORS SUCH AS THESE ARE HEREAFTER COLLECTIVELY TERMED "SYSTEM FAILURES"). ANY

APPLICATION WHERE A SYSTEM FAILURE WOULD CREATE A RISK OF HARM TO PROPERTY OR PERSONS

(INCLUDING THE RISK OF BODILY INJURY AND DEATH) SHOULD NOT BE RELIANT SOLELY UPON ONE

FORM OF ELECTRONIC SYSTEM DUE TO THE RISK OF SYSTEM FAILURE. TO AVOID DAMAGE, INJURY,

OR DEATH, THE USER OR APPLICATION DESIGNER MUST TAKE REASONABLY PRUDENT STEPS TO

PROTECT AGAINST SYSTEM FAILURES, INCLUDING BUT NOT LIMITED TO BACK-UP OR SHUT DOWN

MECHANISMS. BECAUSE EACH END-USER SYSTEM IS CUSTOMIZED AND DIFFERS FROM NATIONAL

INSTRUMENTS' TESTING PLATFORMS AND BECAUSE A USER OR APPLICATION DESIGNER MAY USE

NATIONAL INSTRUMENTS PRODUCTS IN COMBINATION WITH OTHER PRODUCTS IN A MANNER NOT

EVALUATED OR CONTEMPLATED BY NATIONAL INSTRUMENTS, THE USER OR APPLICATION DESIGNER

IS ULTIMATELY RESPONSIBLE FOR VERIFYING AND VALIDATING THE SUITABILITY OF NATIONAL

INSTRUMENTS PRODUCTS WHENEVER NATIONAL INSTRUMENTS PRODUCTS ARE INCORPORATED IN A

SYSTEM OR APPLICATION, INCLUDING, WITHOUT LIMITATION, THE APPROPRIATE DESIGN, PROCESS AND

SAFETY LEVEL OF SUCH SYSTEM OR APPLICATION.

© National Instruments. All rights reserved. 195

NI Combustion Analysis System Software for LabVIEW

User's Manual

9.6 Environmental Management

National Instruments is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial not only to the environment but also to NI customers.

For additional environmental information, refer to the NI and the Environment Web page at ni.com/environment . This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document.

© National Instruments. All rights reserved. 196