Kandolite KMLSP60W User manual
Add to my manuals13 Pages
Kandolite KMLSP60W is a versatile LED moving head light designed for various professional lighting applications. With its advanced features and capabilities, it offers dynamic and customizable illumination effects. The fixture utilizes a powerful 60W white LED source, providing exceptional brightness and color rendering.
KMLSP60W offers precise control over pan and tilt movements, allowing for accurate beam positioning and dynamic effects. It supports DMX512 control with various channel options, enabling integration into complex lighting systems. The comprehensive DMX control allows for programming of intricate light shows, chases, and color changes.
advertisement
USER MANUAL KMLSP60W Index Summarize ......................................................................... 3 Statement .......................................................................... 3 Safety instruction ............................................................... 4 Installation instruction ........................................................ 5 Display operation instruction............................................... 6 DMX controller function ....................................................... 7 XRL connection instruction .................................................. 9 General troubleshooting .....................................................10 Maintenance.......................................................................10 Lamp cleaning……………...………….…………………………..………11 Technical’s specification…………….………………………..……..…12 Summarize Thank you for purchasing our LED Moving lighting. Please read these instructions carefully before begin and operate the fixtures according to these instructions to avoid any possible damages and accidents causes by misusage. Statement Thank you choosing our professional KMLSP60W LED moving head light This user guide includes very important to guarantee the safe and proper use of the light, please read carefully and operate according to the instruction The moving head light applied advanced design and processing technique, adopted new type high intensity high temperature resistant engineering injected plastics. With modern, streamlined and beautiful outlook. The product has well capability and intact packing when leaving factory. All the users should comply with above warning item and operation. Any misuses causing the damages are not included in our guarantee. Any dealers won’t be responsible for any malfunction & problem owing to ignoring the manual. Please forgive that we will not notice for technical changing Safety Information ! Enquire the skilled people before any repair; ! Always make sure disconnect from the power source before setting up, serving and moving;. ! Avoid direct eye exposure to the fixture when it is on; Packing list • KMLSP60W 1PC • Power cable • user manual Page 3 of 13 Safety instruction • Please consult eligible personas before maintenance • Please make sure the power supply has been cut off during installation, maintenance, and transportation. • Please do not use power supply and lamps of different specifications • During operation, the high temperature the light creates might lead to danger, therefore please don’t put any inflammable and explosive things around the light, and please don’t touch the light body during operation. • Make sure there is more than 1 meter between the light and the irradiated objects • In order to avoid harming your eyes, please don not lock at the light beam directly Page 4 of 13 Installation instruction Dimension Diagram • The product is suitable for indoor use only, operation temperature is below 35 degree • The installation, operation and maintenance persons must get familiar with the light performance before operation, so that to avoid damage during transportation before fist usage • Before changing the LED module, please make sure the electric power is cut off and the lamp is cooled off. (bulb temperature can reach abobe 200 degree.) • Cover the small lid. • Install the product in well ventilated places and please note to check whether the fan and the fan are unimpeded or not • Connect the bicolor line (yellow and green) to the ground. Page 5 of 13 Display Operation MENU : access the menu or return to a previous menu option ENTER : select the current menu option UP : menu selection or parameter increments DOWN : menu selection or parameters decrease • Address code • Reset • Auto • Fast • Slow • Sound • Slave • Pan reversal • Tilt reversal • Channels option • 9 channels • 10 channels • 15 channels • Load default Page 6 of 13 DMX Control Function Mode 9 Mode 10 Mode 15 DMX value control function CH 1 CH 1 CH 1 0 - 255 X : Pan CH 2 CH 2 CH 2 0 - 255 Y : Tilt CH 3 0 - 255 X : Pan, Fine CH 4 0 - 255 Y: Tilt, fine CH 3 CH 3 CH 5 0 - 255 X, Y : Pan / Tilt speed, fast to slow CH 4 CH 4 CH 6 0 - 255 intensity Zero to full shutter , 0-7 CH 5 CH 5 CH 7 8 - 250 251 - 255 strobe open strobe. Slow to fast open color wheel 0 - 15 CH 6 CH 6 CH 8 open (white) 16 - 31 Red 32 - 47 Green 48 - 63 Blue 64 - 79 Yellow 80 - 95 Rose Red 96 - 111 112 - 128 Light Green Light Blue color river (clockwise of rotation, 129 - 191 slow to fast) color river (anticlockwise of rotation, 192 - 255 slow to fast) fix gobo wheel 0-6 CH 7 CH 9 open (white) 7 - 13 gobo 1 14 - 20 gobo 2 21 -27 gobo 3 28 - 34 gobo 4 35 - 41 gobo 5 42 - 48 gobo 6 49 - 55 gobo 7 56 - 62 gobo 8 63 - 69 gobo 8 (shake slow to fast) 70 - 76 gobo 7 (shake slow to fast) 77 - 83 gobo 6 (shake slow to fast) 84 - 90 gobo 5 (shake slow to fast) 91 - 97 gobo 4 (shake slow to fast) 98 - 104 gobo 3 (shake slow to fast) 105 - 111 gobo 2 (shake slow to fast) 112 - 118 gobo 1 (shake slow to fast) 119 - 125 open (white) gobo river (clockwise of rotation , 126 - 192 slow to fast) gobo river (anticlockwise of 193 - 255 rotation , slow to fast) gobo effect wheel 0 - 18 CH 7 CH 10 open (white) 19 - 37 gobo 1 38 - 56 gobo 2 57 - 75 gobo 3 76 - 94 gobo 4 95 - 113 gobo 5 114 - 127 gobo 6 gobo river (clockwise of rotation , 128 - 191 slow to fast) gobo river (anticlockwise of 192 - 255 rotation , slow to fast) gobo rotation effect wheel 0-7 close gobo clockwise of rotation , slow to 8 -119 CH 8 CH 8 CH 9 CH 11 CH 12 fast gobo anticlockwise of rotation, slow 120 - 229 to fast 230 - 255 gobo rotation, slow to fast 0 - 255 focus Prism 0- 15 CH 9 CH 0 CH 13 CH 14 CH 15 close 16 - 239 Prism , slow to fast 240 -255 stop 0 - 249 close 250 - 255 reset 0 - 127 close 128 - 255 pan, tilt macro program Page 8 of 13 XLR cable connecting XRL cable: : The stand connection way of the XRL is: one end connects to the male plug, and the other connects to the female. Noted: In order to avoid failures and interference signal transmission, we connect a resistance120Ω( 1/4W) at the end of the DMX connecting as below: Page 9 of 13 The Conversion between 3pin and 5 pin XLR If the output cable of DMX512 controller is the 5PIN, please use 1pc 5PIN to 3PIN cable General troubleshooting Failure description Fail to start The normal lamp is not measure Power fuse intact bulb Inspect DMX start address setting controlled by the controller Check XLR signal lines Intermittent working Inspect the dust and oil of the fans, whether the dust plug fans and nets fans Dim light, the brightness decrease Beam impurities (halo) Bulbs expiry Check whether the optical system is clean Clean the dust and old of the light bulbs, lenses and other components Serious beam distortion Check whether the lens is rupturing Cleaning dust or oil Noted: only professional persons can do as above! Page 10 of 13 Maintenance • When the light has broken and other damage should be promptly replace. • When the light bulb has deformation, the damage should be immediately replaced. • When the lamp not boot, check whether the lamp power supply fuse blown, such as blown, fuse fitted on the corresponding specifications. Attention to the need to use the same specifications of the fuse. Lamps equipped with overheating protection device. • When the overheating protection device will automatically cut off power supply. • When this happens, check whether the normal operation of the fan, fans and whether or not there is dust plug the net to fine out after the start troubleshooting lamps. But take note that qualified technical personnel are allowed to carry out maintenance work. Lamp cleaning • In order to ensure reliable use of lamps to maintain clean the lamp is very necessary. • Cooling fan should be clean once every 15 days. • Internal and external optical lenses, reflectors and filter cleaning coating must be carried out periodically to optimize light output efficacy. • Do not use any solvent contacting the chemical constituents of cleaning filter coating. • Cleaning operation of the lamp, as the frequency and use the surrounding environment, with a soft cloth when cleaning and general cleaning products for cleaning glass, it is recommended at least every 20 days once clean external optical system, at least every 30 / 60 days of a clean internal optical system. Page 11 of 13 • Do not use alcohol and other organic solvents to clean lamp shell, so as • to avoid causing damage. Technical Specification • Power supply : AC 120v / 230v / 60/50Hz • Control : DMX 512 • Channels : CH09, CH10 & CH15 • Power consumption : 140w • Light source : 60w white color LED • Net weight : 13.5Kg • General : 15.5Kg Page 12 of 13 Copyright 2012 KANDOLITE. All rights reserved. Due to continuous improvements and innovations, specifications may change without notice.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project