WST WBT-100 manual

Add to My manuals
8 Pages

advertisement

WST WBT-100 manual | Manualzz

WeighSouth

WBT Toploader Balance

Part List

Balance .....................................................................................1 pc.

Weighing Pan .........................................................................1 pc.

Draft Shield (Model WBT-100 only) ................................1 pc.

Calibration Weight .................................. WBT-100, WBT-602

AC Adapter ..............................................................................1 pc.

Instruction Manual...............................................................1 pc.

Unpacking

Carefully unpack the balance and remove it from its styrofoam supports. You may want to keep the original box and packing materials for storing the balance when not in use.

If the balance is damaged contact the supplier immediately.

Keep all packing materials as they were when you received them.

Setting up the Balance

Place the balance on a level surface, free of vibration.

In order to keep you balance functioning at its best we suggest thay you do the following:

• Avoid Extremes of temperature.

• Do not place in direct sunlight or near air conditioning vents.

• Make sure the balance is located on a strong table and free from vibration.

• Avoid unstable power sources.

• Do not use near large users of electricity such as welding equipment or large motors.

• Keep free from vibration. Do not place near heavy or vibrating machinery.

• Avoid high humidity that might cause condensation

• Keep away from direct contact with water. Do not spray or immerse the balance in water.

• Do not place near open windows, air-conditioning vents or fans that may cause a draft and unstable readings.

Technical Specifi cations

Model

Capacity (g)

Readability (g)

WBT-100

100 g

0.001

WBT-602

600 g

0.01

WBT-5001

5000 g

0.1

Weighing units

Zero range g, kg, oz, ct, lb, t, ozt, dwt, GN

To capacity by subtraction

Stabilization time 3.5 seconds

Optimum operating temp.

Power requirements

2.5 seconds

64°-77°F / 18°-25°C

8-AA alkaline batteries (included) or AC adapter

(included)

Calibration User calibration from keypad

LCD (0.75”)

5” dia 7” x 6”

Display (in/mm)

Pan size L x W (in/cm) 3” dia

Dimensions H x W x L 9.5” (H) x 7.5”

(in/cm) (W) x 10.5” (L)

Draft Shield

Net Weight (lb/kg)

6.5” x 6.5” x 6”

9 lb

3” (H) x 7.5” (W) x 10.5” (L)

Optional

6 lb

NA

5.06 lb

Model

Gram (g)

Kilogram (kg)

WBT-602

600 x 0.01

0.6 x 0.00001

WBT-5001

5000 x 0.1

5 x 0.0001

WBT-100

100 x 0.001

0.1 x 0.000001

Decimal Ounce (oz) 21.2 x 0.0001

176 x 0.001

3.52 x 0.00002

Carat (ct) 3000 x 0.05

25000 x 0.5

500 x 0.005

Decimal Pound (lb) 1.3 x 0.00001

11 x 0.0001

0.22 x 0.00001

Troy Ounce (ozt) 19.3 x 0.0001

160 x 0.001

3.2 x 0.00002

Pennyweight (dwt) 385.8 x 0.01

Grain Unit (GN) 9259.4 x 0.1

3215 x 0.1

77161.7 x 1

64.3 x 0.001

1543.2 x 0.01

Turning on the Balance and Self-testing

1. Connect the AC adapter to an available wall socket and plug the other end of the cable into the balance.

2. Press the ON / OFF key to turn the scale on. A display test will be performed (5 seconds).

3. Once the display shows “0.0g” the balance is ready to use.

4. To turn the scale off , press the ON / OFF key

Sample Weighing

1. Press TARE / ZERO to make the balance return to zero.

2. Load the sample onto the scale pan.

3. The weight is stable when g (depending on which weighing unit is active) appears on the display.

Weighing with Container

Sometimes it is necessary to weigh an object (such as a liquid) using a container. To display just the weight of the contents (net weight) and not the whole combined weight

(gross weight), the TARE button is used.

1. Place an empty container on the weighing pan.

2. Once the weight stabilizes, press the TARE / ZERO key briefl y. The display will return to zero.

3. Add the sample to the container.

4. The weight is stable when “o” appears in the top right corner of the display.

Unit Switching

This balance has 10 possible weighing units. They are gram (g), carat (ct), pound (lb), ounce (oz), troy ounce (oz), grain (GN), pennyweight (dwt), Newton (N), Tola (T), and

T/A/R. Follow these instructions to change the weighing unit:

1. Press the UNIT button.

2. The weighing unit will cycle between the diff erent weighing units with each press of the button.

Parts Counting

With items of uniform weight (ie. all the pieces are of equal weight value) it is possible to use this scales parts counting feature to quickly and accurately obtain a piece count. To use the parts counting feature, follow these instructions:

1. Press the MODE key until the display shows “pcs” to indicate parts counting mode.

2. The display will show “10 pcs” to indicate that you should place a sample quantity of 10 pieces onto the platform. You may change the sample size by pressing the “CAL” button. Possible sample sizes are 10, 20,

50, 100, 150, 200, 250, and 500.

3. Press MODE again once you have selected the sample quantity placed on the platform.

4. You can now add any number of pieces to the platform (or container) and the display will show a count.

5. To exit counting mode press the MODE key.

Notes: The larger the sample size used, the more accurate the count will be. Tare can be used in this mode.

Calibrating the Balance

The balance may need to be calibrated in certain situations such as:

Before weighing for the fi rst time

After the balance has not been used for some time

If the balance location has changed

If ambient temperatures have changed greatly

1. Clear the weighing pan and press TARE to re-zero the balance.

2. When the balance is stabilized press and hold the CAL button for 5 seconds.

3. The display will show “-CAL-” then the required weight will fl ash on the display.

4. Place the calibration weight onto the center of the platform and wait for the display to stop fl ashing.

5. You may now remove the weight. The scale will return to normal weighing mode

Linear Calibration

Linear calibration adjusts the balance at two or more points, rather than just one. To enter linear calibration, follow these steps:

1. Clean the weighing pan and press TARE to re-zero the balance.

2. When the balance is stabilized, press and hold the CAL button for 5 seconds.

3. The display will show “-CAL-”, then the standard calibration weight will fl ash on the display.

4. At this point, press and hold the MODE button for 5 seconds.

5. The display will fl ash the fi rst required calibration weight for linear calibration. Place the required weight onto the center of the platform.

6. Once the weight is accepted, the display will fl ash the next required calibration weight. Place the required weight onto the center of the platform. The weights value will be displayed when it is accepted.

Care & Maintenance

Please read all operating instructions carefully before use. Scales are precision instruments and should always be handled with proper care. To ensure years of reliable service, keep these simple tips in mind:

• Do not exceed the scales maximum capacity. Overloading your scale can permanently damage it!

• Avoid exposure to extreme heat or cold. Scales perform best at normal room temperature. If temperatures have changed dramatically, recalibration may be necessary.

• Allow your scale to warm up for three hours before performing initial calibration.

• Store your scale in a clean, dry location. Dust, dirt, and moisture can accumulate on the weighing sensors and electronics causing inaccuracy or malfunction.

• Avoid static electricity sources, as they can have an adverse eff ect on the weighing sensors.

• Always weigh on a fl at and level surface, free from vibrations and drafts. The corner of a room is usually the most stable.

• Gently apply all items to be weighed. Do not drop items onto the weighing platform.

• Avoid dropping your scale. The warranty does not cover damage due to rough treatment or overload.

• Keep the weighing pan clean using a soft cloth. Do not use harsh chemicals.

materials and workmanship, and to conform to its published product specifi c cautions under normal use and service for the period of one year commencing from the date of purchase.

applies only to product failures due to defective materials and/or workmanship. Without limiting the generality of the foregoing, the foregoing warranty will not apply if, upon inspection, it is found that the product was: misused or abused; used for a purpose for which it was not designed; mishandled; placed in an improper environment; repaired by unauthorized personnel; or improperly installed or adjusted.

going warranty shall be for the original purchaser to return the prodrepaired or replaced under the foregoing warranty shall be shipped back to customer freight and insurance prepaid.

going warranty shall be for the original purchaser to return the prodrepaired or replaced under the foregoing warranty shall be shipped back to customer freight and insurance prepaid.

IN NO EVENT SHALL THE MANUFACTURER BE LIABLE FOR

ANY LOSS, INCONVENIENCE, OR DAMAGE, INCLUDING

WITHOUT LIMITATION DIRECT, OR INDIRECT, SPECIAL,

INCIDENTAL OR CONSEQUENTIAL DAMAGES, RESULTING

FROM OR RELATED TO THE USE OR INABILITY TO USE A

PRODUCT, WHETHER RESULTING FROM BREACH OF WAR-

RANTY OR ANY OTHER LEGAL THEORY, EVEN IF THE MAN-

UFACTURER HAS BEEN ADVISED OF THE POSSIBILITY OF

SUCH INCONVENIENCE, DAMAGE OR LOSS.

advertisement

Related manuals

Frequently Answers and Questions

What is the maximum weight capacity of the WBT-100?
The WBT-100 has a maximum capacity of 100 grams.
What is the readability of the WBT-100?
The WBT-100 has a readability of 0.001 grams.
How many weighing units does the WBT-100 have?
The WBT-100 has 10 weighing units: grams, kilograms, ounces, carats, pounds, troy ounces, pennyweights, grain units, Newtons, Tolas, and T/A/R.
How do I turn on the WBT-100?
To turn on the WBT-100, connect the AC adapter to a wall socket and plug the other end of the cable into the balance. Then, press the ON/OFF key.
How do I tare the WBT-100?
To tare the WBT-100, press the TARE/ZERO key. The display will return to zero.
How do I change the weighing unit on the WBT-100?
To change the weighing unit on the WBT-100, press the UNIT button. The weighing unit will cycle between the different weighing units with each press of the button.
How do I calibrate the WBT-100?
To calibrate the WBT-100, clear the weighing pan and press TARE to re-zero the balance. When the balance is stabilized, press and hold the CAL button for 5 seconds. The display will show "-CAL-" and the required weight will flash on the display. Place the calibration weight onto the center of the platform and wait for the display to stop flashing. You may now remove the weight. The scale will return to normal weighing mode.