Gianni WLP-100 is a robust wireless power transfer system designed to provide power and control to electric locks on doors. It eliminates the need for physical wiring between the door and the frame, making it an ideal solution for retrofitting existing doors or installing new ones. With its inductive coupling technology, the WLP-100 ensures reliable power transmission with a maximum door gap of 3/16 inches (4~5 mm) and allows for some horizontal and vertical misalignment. It features various input power options, including 27.
advertisement
WLP-100 Wireless Power Transfer
Installation Instruction
25
Specifications
Transmitter on Frame Side
Input Power 27.6 VDC or (24VAC)
Current Draw
1A/27.6VDC
1.3A/24VAC
*Requires 1.5 A power when energized
Lock Status Output
Door Status Output
Relay (Dry contacts: N.O./N.C./Com.)
Rating: 3A/ 30VDC
Reed Switch
(Dry contacts: N.O./N.C./Com.)
Rating: 0.1A/ 20VDC
Receiver on Door Side
Output Power 12/24 VDC
Current Draw
Lock Status Input
Infrared Sensing
Door Opening Time
800mA/12VDC
400mA/24VDC
Dry contacts: N.O./Com.
Transmitter Receiver
15 / 30 seconds
*For fail-secure locks only
3/16” (4~5mm) Maximum Door Gap
Maximum Tolerance with 3/16" (4~5mm)
Door Gap
Horizontal alignment : 1/16" (1mm)
Vertical alignment : 1/16" (1mm)
IR Sensing: 1/16” (1mm)
Operating Temperature 32° to +120.2°F ( 0° to +49°C )
Humidity 0 to 85% Non-condensing
IR Transmitter
Unit: mm
3
33.5
Inductive Coupling
Power Transfer
Receiver
Unit
Transmitter
Unit
1
Copyright © All Rights Reserved. P-MU-WLP-100 Published: 2021.03.05
Installation &Wiring
Included in Package
Door Side Unit
Wood Screws
Frame Side Unit
Metal Screws
Door Side Template
Mounting Tabs
Frame Side Template
Washers
Note: For optimal performance, it is recommended to minimize the door gap and use the supplied
templates. The WLP-100 allows for some horizontal and vertical misalignment. Tolerance for
minor misalignment will increase as door gap decreases.
Installation Steps
1. Door & Frame Inspection
After checking the door and frame conditions, apply the templates at the appropriate location.
The WLP-100 can be installed on the latch side, hinge side, or top of the door.
1a. Apply the door side template.
1b. Apply the frame side template. Make sure to
align the horizontal and vertical centerlines.
Align the centerline on the template.
2. Metal Door Installation
2a. Center punch the screw locations for mounting
tabs and counter-sink for M5 screw.
2b. Cut out the main body on the door.
Copyright © All Rights Reserved. P-MU-WLP-100 Published: 2021.03.05
2
2c. Check if the WLP-100 fits well in the cutout and
use the file if necessary.
2d. Install mounting tabs using M5 screws.
3. Wood Door Installation
3a. Drill two 1" (25mm) diameter holes,
1/8" (3mm) in depth as shown on the
template.
3b. Drill and cut the WLP-100 main body to a
minimum depth of 1-9/16” (40mm), and
diameter of 1" (25mm) on the door side.
3c. Use the chisel to straighten the sides.
3d. Check if the WLP-100 fits well in the cutout
and use the file if necessary.
Copyright © All Rights Reserved. P-MU-WLP-100 Published: 2021.03.05
3
3e. For the door side unit, drill a wiring
channel to the electrified device to
be powered.
4. Selecting the Lock Output Voltage
Use the jumper on the back of the door side unit to select the appropriate lock voltage.
Receiver
Unit
12VDC
24VDC
OUTPUT
Jumper Setting
12VDC 24VDC
5. Frame Installation
For the frame side unit, repeat steps 2 or 3 to install on a metal or wood frame.
Wiring Instructions
Please refer to the wiring diagrams on page 5, 6.
WLP-100 Pigtail
Transmit
Unit
24VAC/DC
INPUT
Frame
(Transmitter)
Input Power
Reed Switch
Relay Output
(Lock Status)
Wire Color
Red (+)
Black (-)
Red
Black
White
Yellow
Green
Blue
Function
27.6VDC / 1.5Amp
24VAC / 1.3Amp
Ground
N.C.
COM.
N.O.
N.C.
COM.
N.O.
Blue N.O.
Lock Status
Input
Green COM.
12VDC
24VDC
OUTPUT
Door Leaf
(Receiver)
Red (+)
Lock Power
Output
12 or 24VDC
(select through jumper setting)
Black (-)
Copyright © All Rights Reserved. P-MU-WLP-100 Published: 2021.03.05
4
WLP-100 Wiring Diagram (1)
RED (N/C)
BLK (COM)
WHT (N/O)
Door Status Output
Power Input
POWER
SUPPLY
RED(+)
BLK(-)
27.6VDC / 1.5Amp
YEL (N/C)
GRN (COM)
BLU (N/O)
Lock Status Output
Transmitter
Unit
Receiver
Unit
Jumper
12VDC
12VDC
24VDC
OUTPUT
INPUT
Power Output
Lock Status Input
RED(+)
BLK (-)
GRN (COM)
BLU (N/O)
12V (+)
12V (-)
Fail-Secure
Electric Lock max 12VDC
@800mA
Copyright © All Rights Reserved. P-MU-WLP-100 Published: 2021.03.05
5
WLP-100 Wiring Diagram (2)
N.O.
COM.
N.C.
TLM-300S
Lock Status LED Indicator
POWER
SUPPLY
27.6VDC / 1.5Amp
Door Status Output:
N.O. contact when door close
N.C. contact when door open
Anti-tailgating function for Relay 2 only
IN+
IN -
N.O.1
COM.1
N.C.1
PB
PB
N.O.2
COM.2
N.C.2
REED
REED
N.O.
Transmitter
Unit
COM.
N.C.
N.O.
COM.
Receiver
Unit
N.O.
COM.
Jumper Setting
12VDC 24VDC
DG-15LD
Digital Keypads
GML-800 (Lock)
Fail-Secure Mode
COM. N.O.
Problem Possible Cause Solution
Unable to
unlock
(Transmitter)
Insufficient power output
(Both)
No sensor
output
(Both)
No power
Check that the power supply is connected and works properly
Make sure access control relay contact is wired correctly (N.O.)
Check jumper settings are correct
Check door opening time is not too long (the interval time is 30 seconds)
Installation position is incorrect
Check installation position/alignment is correct
Check door gap does not exceed maximum recommended distance
(Package including washers for minimizing gap)
No door status output
Check installation position/alignment is correct
No lock status output
Check installation position/alignment is correct
Make sure lock status wires are connected to wireless power source
Copyright © All Rights Reserved. P-MU-WLP-100 Published: 2021.03.05