HORIZON

Warning Stick Manual

WIRING

SINGLE / DUAL COLOR

RED

BLACK

GREEN

BROWN

YELLOW

Fuse Rating

No. of

Lighthead s

12VDC

Model

24VDC

Model to +VDC with rated fuse

(for correct fuse, refer to Fuse Rating chart)

2-Head 2.0A

4-Head 4.0A

to Chassis ground

[+] Warning Mode 2 [P1]

[+] Warning Mode 1 [P2]

[+] Flash Pattern Selection / Synchronization

Connect YELLOW wires of all sticks together for synchronization

(All sticks should be set to the same pattern)

[+] Low Power Operation

1.0A

2.0A

1

2

3

4

5

6

7

8

Random

All

All

All

All

All

All

All

9 All

10 All

Warning Patterns

Double [R65] #

Single [2HZ]

Triple [2HZ]

Quad [2HZ]

Steady / Scene

Single [SAE, CA13]

Double [SAE]

Mega

Ultra [SAE]

SC

SC

SC

SC

SC

SC

SC

SC

SC

SC

11 All Single-Quad SC

NOTE: [Px] = Precedence order, when more than (1) wire is activated at the same time, the higher precedence wire will affect lower precedence wire. P1 bein g the highest priority.

POWER WIRES

1. Route Power Wires to the vehicle firewall towards the battery and follow the factory wiring harness through the firewall. If drilling a hole is required, ensure that no component is damaged from the drilling.

2. Install a fuse (user-supplied) to the end of the RED wire, and connect it to the battery. (for correct fuse, refer to Fuse Rating chart)

3. Connect the BLACK wire to the factory chassis ground next to the battery.

NOTE: Ensure that all wires of the power cable are securely connected to the power

source.

CONTROL WIRES

1. Route Control Wires towards the dash area to a switch panel (user-supplied).

2. Connect the required wires to the switch panel or power source.

WARNING MODE 1 and MODE 2

Each warning mode is capable of storing / saving one pattern.

To change the flash pattern:

1. Activate the desired Warning Mode by applying +VDC to BROWN , or GREEN wire.

■ BROWN wire for Warning Mode 1.

■ GREEN wire for Warning Mode 2

2. Let the warning mode run for at least 3 seconds then: a. tap YELLOW wire to +VDC scroll through warning patterns.

b. tap YELLOW wire to +VDC quickly 3 to revert back to flash pattern #1.

COLOR MODE SETTING (available w/ dual color models only):

1.

Disconnect all power , then apply +VDC to BROWN ( or GREEN ), YELLOW and

RED wire together for at least 3 seconds to enter color setting; the stick will display the current color mode for the activated warning mode.

2.

Tap +VDC to YELLOW wire to scroll through the color mode: a.

Color 1 b.

Color 2 c.

Color 1&2 Alternating flash d.

Color 2&1 Alternating flash

3.

Save and exit color setting mode by disconnecting all power.

LOW POWER / DIMMING MODE

Activate dimming function by continuously applying +VDC to WHITE wire.

12 All

13 All

14 Left Right

15 Left Right

16 Left Right

17 Left Right

18 Side-by-Side

19 Side-by-Side

20 Side-by-Side

21 Side-by-Side

Single H/L

Single-Triple-Quint

Single

Double

Mega

Ultra

Single

Double

Mega

Ultra

SC

SC

SC

SC

SC

SC

SC

SC

SC

SC

22 Outside-in

23 Outside-in

Single

Double

SC

SC

24 Outside-in Mega SC

25 Outside-in Ultra SC

26 All

27 Split

Scan

Scan

SC

SC

28 Left Right Single Mid SC/DC

29 Left Right Double-Single SC/DC

30 Left Right

31 Left Right

Triple-Single

Quad-Single

SC/DC

SC/DC

32 Left Right

33 Left Right

Single H/L II

Double-Blast

SC/DC

SC/DC

34 Left Right

35 Left Right

Swing I

Triple-Blast

SC/DC

SC/DC

36 Left Right

Swing II

SC/DC

37 Left Right

Swing III

SC/DC

38 Left Right

39 Side-by-Side

40 Side-by-Side

Triple H/L

Single Fast

Quad Fast

SC/DC

SC/DC

SC/DC

41 Side-by-Side

Double Fast

SC/DC

42 Side-by-Side

Quad-Double

SC/DC

43 Composit

44 Side-by-Side

Quad-Scan-Blast

Mega X *

All Scan-Split Scan

SC/DC

SC/DC

45 Composite SC/DC

46 Composite

47 Composite

Triple-Scan

Single-Scan-Blast

SC/DC

SC/DC

48 Composite

49 Composite

50 Composite

Solid Scan *

Solid Scan-Mega *

Solid S c an-Blast *

SC/DC

SC/DC

SC/DC

# Actual ECE R65 approval is based on the p/n ordered.

* Patterns show full effect in dual color mode.

For dual color models:

SC = Single Color Mode; SC/DC = Single or Dual Color Mode

-1-

FIRMWARE SELECTION

All units are pre-set to the firmware of its number of lightheads.

To change firmware:

1. Applying +VDC to RED and YELLOW wires simultaneously for more than 3 seconds to enter FIRMWARE selection.

2. Once in FIRMWARE selection mode, the unit will display one of the following patterns.

2-Head Warning Stick steady

4-Head Warning Stick steady steady

3. Momentarily apply YELLOW wire to +VDC to scroll through FIRMWARES.

4. Once desired FIRMWARE is selected, save and exit by disconnecting all power.

Q-L

OCK

™ MECHANISM & LIGHTHEAD SWAP

Lightheads in a 4-Head Warning Stick may be quickly removed and swapped using Q-Lock™ Mechanism.

For 2-Head units, one of the end caps must be removed.

1.

Use a flat-head screwdriver to flip open the Q-Lock™ levers on both sides of the lighthead.

2.

Remove the lighthead by pulling it out slowly and evenly from both sides. Inserting a flathead screwdriver into the Q-Lock slot, and into the side of the lighthead to be removed will ease removal.

3.

Carefully disconnect the lighthead wire from the wire harness. Assess the connector set-up making sure to push the knob, freeing it from the clip side. Do not attempt to pull the connector apart by pulling on the wires.

4.

Connect the new lighthead on to the wire harness. Note the direction and the orientation of the lighthead to ensure the replacement head matches the orientation of other lightheads in the stick. (check wire-exit and lens marking)

5.

Push the lighthead slowly and evenly into place.

6.

Flip and close all Q-Lock™ levers.

OPEN

CLOSE

 

OPEN

-2-

advertisement

Key Features

  • Multiple warning patterns and color modes
  • Low power operation for extended use
  • Synchronization capability for multiple units
  • Q-Lock™ Mechanism for quick and easy lighthead swapping
  • Firmware selection for different lighthead configurations
  • Solid and flashing patterns for various warning scenarios
  • Compact and lightweight for easy installation

Related manuals

Frequently Answers and Questions

How many lightheads can the Horizon Warning Stick have?
The Horizon Warning Stick can have either 2 or 4 lightheads.
What is the fuse rating for a 2-Head Warning Stick operating on 12VDC?
The fuse rating for a 2-Head Warning Stick operating on 12VDC is 2.0A.
What is the fuse rating for a 4-Head Warning Stick operating on 24VDC?
The fuse rating for a 4-Head Warning Stick operating on 24VDC is 2.0A.
How do I change the flash pattern on the Horizon Warning Stick?
To change the flash pattern, activate the desired Warning Mode by applying +VDC to the BROWN or GREEN wire. Let the warning mode run for at least 3 seconds, then tap the YELLOW wire to +VDC to scroll through warning patterns.
How do I set the color mode on a dual-color Horizon Warning Stick?
To set the color mode, disconnect all power, then apply +VDC to the BROWN (or GREEN), YELLOW, and RED wires together for at least 3 seconds. Tap the YELLOW wire to +VDC to scroll through the color modes.
How do I activate the dimming function on the Horizon Warning Stick?
To activate the dimming function, continuously apply +VDC to the WHITE wire.
How do I change the firmware on the Horizon Warning Stick?
To change the firmware, apply +VDC to the RED and YELLOW wires simultaneously for more than 3 seconds. Once in firmware selection mode, momentarily apply the YELLOW wire to +VDC to scroll through firmwares. Save and exit by disconnecting all power.