FIXTURE INSTALLATION GUIDE
Model T21T (Low Voltage Pendant Set 120V)
21T, Rev.4 6-13
6695 Taylor Rd. Blacklick, OH 43004 www.besalighting.com
IMPORTANT: Before proceeding, retrieve the GLASS SHADE INSTALLATION GUIDE , which is included with the pendant cord set
CAUTION: Turn off power to electrical box before installing
C
B
A
F
E
*IMPORTANT:
When Mounting To Smaller Boxes,
It May Be Necessary To Secure
Using These Mounting Holes.
G
D
Note:
For optimum performance, an electronic low voltage dimmer should be used. Installation of a low voltage dimmer requires a neutral lead in the switch box for proper wiring.
If employing a standard incandescent dimmer, low levels of noise (”buzzing”) may emanate from either the dimmer or transformer. This is usually caused by dimmer/transformer incompatibility and may be eliminated by simply replacing the dimmer.
1. Carefully unpack parts. Remove the Canopy (A) from the Mounting Plate by unscrewing the Retainer (B).
Fully remove the Retainer from the threaded nipple, then pull the canopy from the Mounting Plate.
IMPORTANT: GLASS SHADE INSTALLATION GUIDE to determine the glass support
parts that must be installed over the Pendant Cord Set, prior to Step 2.
2. To install the pendant cord, simply unscrew the Set Screw on the Strain Relief (C) to loosen.
Now push the cord up through the Retainer, Canopy and then Strain Relief until reaching the
desired length. Shorten cord to approx. 6” above the Strain Relief, per instructions on the Glass
Installation Guide. Tighten the Set Screw onto cord until the cord is held in place.
CAUTION: Overtightening the set screw could pierce cord and prevent pendant from operating.
3. Connect the cord leads to the blue or red transformer wires, and secure with wirenuts (D).
If the cord length above the Mounting Plate is more than 6”, then you will need to shorten the cord.
4. Install the provided Mounting Screws into the Outlet Box, leaving 1/4” of threading as shown.
Attach the house ground wire to the bare copper lead on the Mounting Plate and secure with
provided wirenut (E). Connect the electrical leads from the fixture transformer to the house
supply wires, black to black, white to white, and secure with wirenuts provided (F).
5. Align the circular openings of the keyhole slots (G) of the Mounting Plate with the Mounting screws.
Push the Mounting Plate up over the Outlet Box until tight to ceiling, then rotate the Mounting Plate
Counter-clockwise and secure with Mounting Screws.
6. Position canopy over the threaded nipple and secure with Retainer.
7. For assembly of the glass shade, please refer to the GLASS SHADE INSTALLATION GUIDE
that is included with the Pendant Cord Set.
8. Restore power.
All electrical connections and the installation of this fixture must be in agreement with local codes, ordinances or the NEC (National Electric Code) or CEC (Canadian Electrical Code).
Do not connect this fixture to an electrical system that does not provide a means for equipment grounding.
PENDANT CORD INSTALLATION GUIDE
Model U Series -08 (Low Voltage Pendant Set 12V)
UKIT.08, Rev.4 8-11
6695 Taylor Rd. Blacklick, OH 43004 www.besalighting.com
SHORTENING LENGTH OF PENDANT CORD
Carefully measure the desired length of cord and cut off the excess.
It is important to leave an additional 6” that will be inside the canopy for connection to your transformer. Using the 10 AWG setting, strip off 1-1/2” of outer teflon jacket with a pair of wire strippers.
Gently push the silver metal braiding downward on the cord, causing the braiding to create a bubble shape as shown.
Using a pointed object, such as a pencil, expand an opening in the silver braiding until the inner conductor is clearly exposed.
Once the inner conductor is exposed, it can now be separated from the braiding. Slide the pointed object between the inner conductor and the braiding, as shown. Gently wedge the inner conductor apart from the braiding. Now twist the braiding tightly into a conductor.
Strip 1/2” insulation from the inner conductor. The pendant cord is now ready for installation (Refer to the Canopy Instructions).
After connection to the transformer, it is recommended that any exposed portion of the braided conductor be wrapped with electrical tape.
IMPORTANT: KEEP THESE INSTRUCTIONS FOR YOUR RECORDS
Replacement parts for this Low Voltage Pendant Set are as follows (lamp included):
#TU210C50-SN.08
- 50W, 10’ clear cordset with Nickel Hardware
For Bronze cordset, use “Z” in place of “C” and “BR” in place of “SN”
For 15’ cordsest, use “215” in place of “210”
Lamps Only:
#B5506 - 50W Low-pressure Halogen 12V Bi-Pin GY6.35
GLASS SHADE INSTALLATION GUIDE
Use With these Models:
• Karli
(7198xx)
6695 Taylor Rd. Blacklick, OH 43004 www.besalighting.com
IMPORTANT: For installation of pendants and wiring, please refer to the Fixture Installation Guide included with fixture canopy
1. Begin by threading the Treaded Nipple into the top of the Socket Assembly and
secure using the Lower Hex Nut and Washer provided. Then secure the Washer
between the two Upper Hex Nuts provided. See figure 1.
While holding the Lampholder secure, hold the Lamp by the base, just above
the contacts, and firmly push the lamp into the socket. See figure 1.
NOTE: Lampholder is designed to have a tight fit, so resistance may be
experienced when inserting lamp.
2. Following figure 2, the glass shade (shape may vary) will be positioned as shown.
Lower the glass shade until it rests on the Washer. Depending on the thickness of
glass, the Upper Hex Nuts and Washer may require adjustment to allow the Decorative
Cap to properly seat at top the glass shade.
Decorative Cap
Figure 1
Upper Hex Nuts
Threaded Nipple
Socket Assembly
Lamp
Washer
Relamp with a low-pressure type lamp, either xenon or halogen. Packaging of this lamp will typically indicate that it’s
“Suitable For Use in an Open Fixture” or marked with the symbol shown.
Figure 2
Lamp
All electrical connections and the installation of this fixture must be in agreement with local codes, ordinances or the NEC (National Electric Code) or CEC (Canadian Electrical Code).
Do not connect this fixture to an electrical system that does not provide a means for equipment grounding.
FIXTURE INSTALLATION GUIDE
Model T21QP (Low Voltage Quick-Connect Canopy)
21QP, Rev.3 6-10
6695 Taylor Rd. Blacklick, OH 43004 www.besalighting.com
Caution: Turn off power to electrical box before installing
D
B A
Note:
For optimum performance, an electronic low voltage dimmer should be used. Installation of a low voltage dimmer requires a neutral lead in the switch box for proper wiring.
If employing a standard incandescent dimmer, low levels of noise (”buzzing”) may emanate from either the dimmer or transformer. This is usually caused by dimmer/transformer incompatibility and may be eliminated by simply replacing the dimmer.
F
G
C
E
1. Carefully remove parts from package.
2. Connect the house ground wire to the Bare Copper Lead and secure with wirenut provided (A).
Connect the electrical leads from the Transformer to the house supply wires, black to black and
white to white, and secure with wirenuts provided (B).
3. Align the Openings (C) on the Canopy with the Threaded Holes (D) on the Supply Box.
Push the Canopy over the Supply Box until the Canopy is flush to the ceiling, then secure with the
Threaded Screws (E). It is important that the Supply Box is deep enough to allow for the Transformer.
4. Place the Decorative Cover (F) over the threaded nipple on the canopy, then attach the Besa
Quick Connect Element (G). The Besa Quick Connect Element is furnished separately.
5. With the power still off, insert bulb of not more than the labeled wattage on the Quick Connect Element.
6. Turn power on.
All electrical connections and the installation of this fixture must be in agreement with local codes, ordinances or the NEC (National Electric Code) or CEC (Canadian Electrical Code).
Do not connect this fixture to an electrical system that does not provide a means for equipment grounding.
QUICK CONNECT INSTALLATION GUIDE
Model XP-08 Series (Low Voltage Pendant Set 12V)
XPKIT.08, Rev.6 8-11
6695 Taylor Rd. Blacklick, OH 43004 www.besalighting.com
This low voltage Pendant Cord Assembly has been designed to be used with Besa Low Voltage Quick
Connect Adapters. Operate with a low voltage transformer (12V) and never wire directly to 120 volts.
1. Making a clean cut, shorten the cord to the desired length.
2. Carefully strip off 1-3/4” of the outer jacket using
the Stripping Tool provided.
It is important not to damage the
inner silver braiding. Practice this
step on a scrap section of cord first.
1-3/4”
3. Slide the Brass Collar over the braiding.
Make sure the Brass Collar does not
damage the braiding to ensure
a good connection.
Gently Tighten
Using Pliers
4. Remove the exposed braiding by pulling away from
the center conductor, then cutting off excess.
Leave 1/16” of braided material or less.
5. Strip off 1/8” of insulation from the Center Conductor.
The exposed stranded wire of the Center Conductor
must be tightly wound before proceeding.
1/8”
6. Feed the wire until it reaches the top set screw position. Confirm
by viewing the Center Conductor through the Viewing Hole.
7. The Brass Collar should align with the bottom of the
Quick Connect Jack, if not then trim the Center Conductor.
8. Tighten the top set screw first, then the lower. Do not overtighten
the set screws and make sure the set screws avoid the seam
in the Brass Collar. The pendant can now be installed onto
Quick Connect Adapter.
Orient So Set Screw
Is Not On Seam
9. Insert the post of the Quick Connect Jack into the
Quick Connect Adapter. Thread the top half of the
conical section until it seats with the adapter.
Loosen Set Screws,
If Necessary
IMPORTANT: KEEP THESE INSTRUCTIONS FOR YOUR RECORDS
Replacement parts for this Low Voltage Pendant Set are as follows (lamp included):
#XP-210C50-SN.08
- 50W 10’ clear cordset with Nickel Hardware
For Bronze cordset, use “Z” in place of “C” and “BR” in place of “SN”
For 15’ cordset, use “215” in place of “210”
Lamps and Quick Connect Jacks Only:
#TQJACK-SN - Nickel Quick Connect Jack
#TQJACK-BR - Bronze Quick Connect Jack
#B5506 - 50W Low-pressure Halogen 12V Bi-Pin GY6.35
GLASS SHADE INSTALLATION GUIDE
6695 Taylor Rd. Blacklick, OH 43004 www.besalighting.com
Use With these Models:
• Karli
(7198xx)
IMPORTANT: The pendant and glass assembly you have received is designed such that the glass must be installed prior to hanging the pendant.
1. Begin by threading the Treaded Nipple into the top of the Socket Assembly and secure using the Lower
Hex Nut and Washer provided. Then secure the Washer between the two Upper Hex Nuts provided.
See figure 1.
2. Following figure 2, the glass shade (shape may vary) will be positioned as shown. Lower the glass
shade until it rests on the Washer. Depending on the thickness of glass, the Upper Hex Nuts and
Washer may require adjustment to allow the Decorative Cap to properly seat at top the glass shade.
For lamping, plug the provided 50W Lamp provided. For relamping never exceed 50 watts, as greater wattages could cause overheating, adversely affecting the life of the luminaire.
While performing the remaining instruction steps, care must be taken to keep the glass shade and assembly protected, otherwise breakage may occur.
Decorative Cap
Lower Hex Nut and Washer
Figure 1
Upper Hex Nuts
Threaded
Nipple
Socket
Assembly
Washer
Relamp with a low-pressure type lamp, either xenon or halogen. Packaging of this lamp will typically indicate that it’s
“Suitable For Use in an Open Fixture” or marked with the symbol shown.
Figure 2
Lamp
All electrical connections and the installation of this fixture must be in agreement with local codes, ordinances or the NEC (National Electric Code) or CEC (Canadian Electrical Code).
Do not connect this fixture to an electrical system that does not provide a means for equipment grounding.