Installation Instructions for AccuShot Fertilizer System

for the YP825AR series planter

Before Getting Started

Before you begin installation of your AccuShot Fertilizer

System, read these instructions carefully and check that all parts and tools in kit are accounted for. All hand and specialty tools for installation are provided at owner’s expense. Please retain these installation instructions for future reference and parts ordering information.

These installation instructions contain information for assembling the AccuShot Fertilizer System to the main machine. Please read all instructions in your planter operator manual thoroughly before proceeding. Your operator manual includes information on operation, adjustment, troubleshooting, and maintenance for this attachment (some manual sections do not apply to all accessories).

Instructions contain information for all makes and models of the applicable machines.

General Information

The AccuShot Fertilizer System provides a dose of liquid application per seed placed at a predefined location relative to the seed.

AccuShot Fertilizer System Reference #

Yield-Pro Planter YP8R-16TR 417-846A

Yield-Pro Planter YP8R-0830 417-847A

Tools Required

The following tools are required for installation:

• General hand tools.

Refer to page 10 for torque values chart.

Recommended Manuals

All manuals related to this kit are available free of charge by visiting www.greatplainsag.com. Have machine model and serial numbers available.

Yield-Pro Planter Parts Manuals

YP825AR Parts Manual 401-923P

YP825AR Operator’s Manual 401-923M

AccuShot Operator’s Manual 115700-001

AccuShot Quick Start Guide 115700-002

Refer to the detailed lists of parts included in these kits

beginning on page 11. Use these lists to inventory parts

received.

Installation Guide QRC

The QR Code (Quick Response) to the left will take you to a web installation guide. Use your smart phone or tablet to scan the QR Code with an appropriate App to begin viewing.

Yield-Pro QRC

The QR Code (Quick Response) to the left will take you to the Yield-Pro family of manuals. Use your smart phone or tablet to scan the QR Code with an appropriate App to begin viewing.

© Copyright 2016 Printed 12/06/16 417-911M

2

AccuShot Fertilizer System

Installation Instructions

Preparation

Before you begin installation of your AccuShot fertilizer system, hook the planter to a tractor and move the opener lock handles to “Field”. Unfold the planter and lower the openers to the ground. Place the remote lever in float position to relieve any residual hydraulic pressure. Clean the area around the fan flow control valves by washing or using compressed air.

Getting Started

Check that all parts in the kit are accounted for. Refer

to the parts list starting on page 11. Make sure to

refer to the correct parts lists for your planter.

Make sure any required tools are on hand. See

“Recommended Manuals” on page 1 for a general list of recommended tools for installation.

Familiarize yourself with the machine operator manual and operating hydraulics before starting.

1 Install Liquid Fertilizer Tanks

If your planter has the liquid fertilizer option already installed, go to

“Existing Liquid Fertilizer

Components” on page 3.

1a. Liquid Fertilizer Tanks Installation

Install a right-hand tank support (26) and left-hand tank support (27) to each liquid fertilizer tank (28) with four

1

/

4

inch bolts (1) and flange nuts

(2).

/

2

-13 x 1-

1

Installation Instructions

Install the tank assemblies onto the planter frame using two

1

/

2

-13 5 x 7 inch corner bolts (41) and flange nuts (36) at the front of the frame. Use two

3

/

4

-10 7 inch square corner bolts (40) and flange lock nuts (36).

Install the two hose loop guides (31) to the front of the planter frame with four

5

/

16

-18 x 3/4 inch bolts

(35), lock washers (38), and flat washers (39).

35

39

31

38

36

36 40

41

1b. Liquid Fertilizer Plumbing

Install the right tank fill (30) into the bottom of the right-hand tank.

Remove the plug (1) from the right-hand side of the tank and install an elbow (46).

28

1

46

1

2

26

27

30

Great Plains | 417-911M

AccuShot Fertilizer System Installation Instructions

Install the left tank fill (32) into the bottom of the left-hand tank.

Remove the plug (1) from the right-hand side of the tank and install an adapter (45), ball valve (42), another adapter (45), and the tee (44). On the end of the tee facing the front of the planter, install the valve

(43), and on the other end of the tee, install an elbow

(46).

46

45

42

Put a small hose clamp (33) on the other end of the

3

/

4

inch ID hose. and install the hose to the end of the valve (43) previously installed on the left-hand tank. Put another small hose clamp on the end of a

3

/

4

inch ID hose and install the hose on the elbow

(46). Route the hose through tank supports (1).

Take the 1-

1

/

2

inch ID hose coming from the right tank fill and put a large clamp (34) on the end. Install the hose on the adapter at the back of the left tank fill. Put a large clamp (34) on one end of a 1-

1

/

2

inch

ID hose (48) and install the hose on the elbow at the back of the left tank fill. Route the hose through the tank support (1).

33

47

47

48

34

48

44

43

32 1

1

Put a small hose clamp (33) over one end of the

3

/

4 inch ID hose (47), and install the hose to the elbow on the right side of the right-hand tank. Route the hose through the holes (1) in the tank supports, then through the hose loops (2) on the frame.

Put a large hose clamp (34) on one end of the

1-

1

/

2 inch ID hose (48), and install the hose to the elbow of the right tank fill (34). Route the hose through the tank support (1), then through the hose loops (2).

33

47

34

48

1

1

2

Tighten all hose clamps.

2 Existing Liquid Fertilizer

Components

1

If your planter has an existing liquid fertilizer option with ground drive, use these instructions. If your planter does not, go to

“AccuShot Fertilizer Pump” on page 5

Possible Chemical Hazard:

Wear proper protective equipment as required by chemical manufacturer. Avoid prolonged breathing of chemical fumes.

Wear respirator as required by chemical manufacturer. Some chemicals will cause serious burns, lung damage, and death.

Avoid contact with skin or eyes. Seek medical assistance immediately if accident occurs. Know what to do in case of an accident.

Follow instructions in the Operator’s Manual to clean out the fertilizer tanks.

12/06/16 3

AccuShot Fertilizer System Installation Instructions

2a. Remove Pump Drive

Locate the John-Blue pump (1) on your machine.

Loosen the flanges (2) and remove the two elbows

(3) from the pump.

3

1

2b. Remove Plumbing

All existing plumbing will be removed from the fertilizer tanks and replaced with new plumbing.

Remove all necessary plumbing to remove the valves (1) from the bottom of each fertilizer tank.

Remove the two

3

/

8

-16 x 1 inch bolts (2) on the mounting. Remove the mounting with attached plumbing and valves from the planter frame.

1

2

3

2

Remove the fertilizer ground drive (1) by removing both u-bolts (2) and nuts (3). Remove the fertilizer contact wheel assembly with pump attached.

3

1

1

2

2c. Remove Liquid Fertilizer Boom

Loosen the hose clamp (1) and remove hose (2) from the boom elbow.

Remove the

3

/

8

-16 x 7-

1

/

32

x 6 inch u-bolt (3) from the gauge bracket to remove the gauge and attached plumbing.

Remove the

3

/

8

-16 x 7-

1

/

32

x 6 inch u-bolts (4) that fasten the wet boom (5) to the planter frame.

Carefully remove wet boom from planter.

1

2

2

3

4

5

4 Great Plains | 417-911M

AccuShot Fertilizer System Installation Instructions

3 AccuShot Fertilizer Pump

The fertilizer pump (29) should be pre-assembled and ready for installation.

Attach the mounting to the planter frame, as shown, with two

3

/

8

-16 x 1-

1

/

2

inch bolts (1), flat washers (2), lock washers (3), and nuts (4).

Attach the other mounting to the planter frame with two

1

/

2

-13 x 1and nuts (7).

1

/

2

inch bolts (5), lock washers (6),

Put a large hose clamp (34) on the end of the

1-

1

/

2 inch ID hose (48) coming from the left tank fill.

Attach the hose to the pump as shown. Tighten the hose clamp.

Put a small hose clamp on the end of the

3

/

4 inch ID hose (47) and attach the hose to the bottom of the gauge. Tighten the hose clamp.

29

47

6

7

48

34

4

3

2

1

5

Make sure the hoses (1, 2, 3, and 4) are connected as shown.

2

3a. Hydraulic Connections

The illustration below shows the existing hydraulic hose routing for your machine. Two hoses will need to be disconnected and will be reconnected to the fertilizer pump assembly. Three locations (flow control valve, hydraulic pump, and Veris valve/filter canister) are areas where new components will be added and new hoses connected.

Find the existing hydraulic hose (1) from the flow control valve (2) to the hydraulic motor (3). At the hydraulic motor, disconnect the hydraulic hose from the adapter (4).

Disconnect the hydraulic hose (5) from the elbow above the inline valve on the hydraulic motor.

Remove the adapter (7) between the Veris valve (8) and the filter canister (9).

9

2

7

1

4

5

8

6

3

1

4

12/06/16

3

5

AccuShot Fertilizer System Installation Instructions

Install a tee (9) between the Veris valve and the filter canister. Connect the hydraulic hose (10) from the

PWM valve to the tee.

Route the existing hydraulic hose (1) from the flow control valve (2) to the load shuttle valve (3).

Route the other existing hydraulic hose (4) to the tee

(5) on the pump (6). Route the hydraulic hose (7) from the other end of the tee to the elbow on the inline valve on the hydraulic motor.

Route the hydraulic hose (8) from the elbow on the load shuttle valve (3) to the adapter on the hydraulic motor.

7

2

4

1

Install the AccuShot controller (56) to the controller mount with four

3

/

8

-16 x 1 inch bolts (18), flat washers (21), lock washers (22), and nuts (19).

1

14

19

21

21

22

18 56

4b. Controller Harnesses

For 8-row planters - Plug in the extension harness

(25) to the valve harness (51). Plug in connector B on the extension harness to controller connection B.

Plug in connector C on the accessory harness (58) to controller connection C. Plug in connector D on the power harness (57) to controller connection D.

Route the power harness along the planter tongue.

D

5

8

9

A B C

6

10

3

25

B

4 AccuShot Controller

4a. AccuShot Controller Installation

At the back of the planter, remove the module (1) and keep all hardware. Install the controller mount

(14) and reinstall the module using the existing hardware.

51

58

D

57

C

6 Great Plains | 417-911M

AccuShot Fertilizer System Installation Instructions

For twin-row planters - Plug in the extension harness (12) to the valve harness (53). Plug in connectors A and B on the extension harness to controller connections A and B. Plug in connector C on the accessory harness (58) to controller connection C. Plug in connector D on the power harness (57) to controller connection D.

Route the power harness along the planter tongue.

D

5 AccuShot Wetboom

The wetboom is shipped in two pieces.

Connect the two wetboom assemblies (1) with a tee

(2). Install an elbow (3) to the tee.

3

A B C

A

12

53

B

58

D

57

C

1

Install an AccuShot controller decal (24) on the controller.

On each side of the planter tongue, install the other

AccuShot controller decals.

1

2

1

Install the eight brackets (15) to the air delivery clamps (1) using the existing hardware.

1

15

Position the wetboom evenly so that solenoid nozzles align with machine openers. Install the wetboom to the brackets with eight

5

/

16

-18 x 1-

1

/

2

x

2-

1

/

2

inch u-bolts (23) and nuts (20).

20

24

23

12/06/16 7

AccuShot Fertilizer System

Put a hose clamp on the end of the 1 inch ID hose

(1) from the flowmeter and connect the end of the hose to the elbow (2) on the wetboom. Tighten the hose clamp.

2

Installation Instructions

6b. Valve Harness Connections

Starting on the left-hand side, route the valve harness so each valve (1) on the wetboom aligns with a connector (2) on the harness. Plug in wetboom valves to the valve harness.

Secure the harness with ties included in the kit.

Plug in a seed sensor harness (13) to each valve harness connector (3).

2

3

1

1

13

6 Connect Harnesses

6a. Accessory Harness Connections

Route the accessory harness along the planter frame to the fertilizer pump on the left-hand side.

Plug in the connector (1) to the PWM valve on the fertilizer pump.

Plug in the pressure sensor (61) to the accessory harness and the tee (2) attached to the flowmeter.

Plug in the flowmeter adapter cable (3) to the accessory harness.

Plug in the GPS sensor (59) to the accessory harness.

1 58 2

7 AccuShot Blade Separator

7a. Remove Existing Scraper Separator

Starting with the first opener on the left-hand side of the machine, remove side gauge wheel (1) and hardware.

Remove disk blade (2) and hardware.

Drive out roll pins (3) to remove the existing scraper separator (4).

 NOTE

On some scraper separators, you may need to remove the elbow (5) first.

3

5

1

2

1

61

2

59

3

4

8 Great Plains | 417-911M

AccuShot Fertilizer System

7b.AccuShot Blade Separator Installation

Insert new AccuShot blade separator (1) and secure with roll pins (2).

 NOTE

If roll pins are lost or damaged, order replacements using part number 805-335C.

Installation Instructions

7c. Fertilizer Tubing

Attach one piece of 78 inch long

3

/

8

inch tubing (55) to the solenoid nozzle aligned with the opener. Route the tubing down to the opener. Attach the tubing to the elbow on the blade separator and fasten with a locking clip.

55

2

1

Route fertilizer tube (1) on the blade separator through the opener shield and attach the elbow (50).

Secure the elbow with a locking clip (48).

48

50

1

1

2

Reinstall the disk blade and side gauge wheel onto the opener.

See your planter Operator’s Manual for opener adjustments, if necessary.

Secure the tubing to the opener using supplied zip ties.

Repeat the procedure for the blade separator for each opener.

8 Finishing Installation

Make sure all hardware is tightened to the correct torque from the

“Torque Values Chart” on page 10.

Secure hoses and electrical harnesses with cable ties as necessary to avoid wear.

Refer to the AccuShot Operator’s Manual and Quick

Start Guide for further instructions on operation and maintenance of your AccuShot Fertilizer System.

12/06/16 9

AccuShot Fertilizer System Torque Values Chart

Torque Values Chart

Bolt Head Identification

Bolt

S

ize

Bolt

S

ize

Bolt Head Identification

5.

8 8

.

8

10.9

Grade 2

N-m b

7.4

ft-lb d

5.6

540

6 8 0

750

89 0

150

2 3 5

260

225

250

3 40

3 70

4 8 0

1010

11 8 0

4 9

66

75

9 5

105

1 3 0

8 .5

15

17

27

3 1

4 3

39 5

500

555

655

110

170

1 9 0

165

1 8 5

250

275

3 55

745

8 70

3 6

4 9

55

70

7 9

9 7

6

11

1 3

20

22

3 2

1-12

1

1 e

8

-7

1

1 e

8

-12

1

1 e

4

-7

1

1 e

4

-12

1

3 e

8

-6

1

3 e

8

-12

1

1 e

2

-6

1

1 e

2

-12 in-tpi a

1 e

2

-20

9 e

16

-12

9 e

16

-1 8

5 e

8

-11

5 e

8

-1 8

3 e

4

-10

1 e

4

-20

1 e

4

-2 8

5 e

16

-1 8

5 e

16

-24

3 e

8

-16

3 e

8

-24

7 e

16

-14

7 e

16

-20

1 e

2

-1 3

3 e

4

-16

7 e

8

-9

7 e

8

-14

18

1 33 0 98 0

Grade 5

N-m

11 ft-lb

8

2 3 0

3 60

405

5 8 5

640

8 75

9 55

10 8 0

1210

1520

16 8 0

1 99 0

2270

2640

75

105

115

150

165

205

1 3

24

26

42

47

67

2 9 70

Grade

8

N-m ft-lb

12

3 25

510

570

8 20

9 05

12 3 0

1 3 50

1750

1 9 60

2460

27 3 0

3 2 3 0

3 6 8 0

42 9 0

105

145

165

210

2 3 5

2 8 5

1 8

33

3 7

5 9

67

9 5

240

3 75

420

605

670

9 10

99 5

12 9 0

1440

1 8 20

2010

2 38 0

2710

3 160

7 8

105

120

155

170

210

14

25

27

44

4 9

70

170

265

2 9 5

4 3 0

475

645

705

7 9 5

89 0

1120

1240

1470

1670

1 9 50

55

76

8 5

110

120

150

10

17

1 9

3 1

3 5

4 9

21 9 0 4 8 20 3 560 mm x pitch c

M 5 X 0.

8

M 6 X 1

M 8 X 1.25

M 8 X 1

M10 X 1.5

M10 X 0.75

M12 X 1.75

M12 X 1.5

M12 X 1

M14 X 2

M14 X 1.5

M16 X 2

M16 X 1.5

M1 8 X 2.5

M1 8 X 1.5

M20 X 2.5

M20 X 1.5

M24 X 3

M24 X 2

M 3 0 X 3 .5

M 3 0 X 2

M 3 6 X 3 .5

M 3 6 X 2

3 10

3 50

440

650

760

83 0

1510

16 8 0

2650

2 9 60

9 5

105

145

155

225

240

11

26

2 8

52

61

9 1

145

165

205

2 3 0

3 55

39 0

705

7 8 5

1270

1 38 0

44

66

6 8

7 3

105

115

5

12

1 3

24

2 9

42

Cla

ss

5.

8

Cla

ss 8

.

8

Cla

ss

10.9

N-m

4 ft-lb

3

N-m

6 ft-lb

5

N-m

9 ft-lb

7

1 9 5

220

2 8 0

3 10

4 8 0

525

9 60

1060

17 3 0

1 88 0

60

9 0

9 2

99

145

155

7

17

1 8

33

39

5 8

Tor qu e toler a nce + 0%, -15% of tor qu ing v a l u e s . Unle ss otherwi s e s pecified us e tor qu e v a l u e s li s ted ab ove.

405

4 8 5

610

9 00

1050

1150

2100

2 3 20

3 660

4100

1 3 0

145

200

215

3 15

33 5

15

3 6

39

72

8 5

125

2 3 0

260

3 25

4 8 0

560

610

1120

1240

1 9 50

21 9 0

70

77

105

115

165

1 8 0

8

1 9

21

39

45

67 a . in-tpi = nomin a l thre a d di a meter in inche s -thre a d s per inch b . N· m = newton-meter s c. mm x pitch = nomin a l thre a d di a meter in mm x thre a d pitch d. ft-l b = foot po u nd s

3 00

3 55

450

665

7 8 0

8 45

1550

1710

2700

3 220

9 7

105

150

160

2 3 0

245

11

27

2 9

5 3

62

93

251 99 m

10 Great Plains | 417-911M

AccuShot Fertilizer System

Parts Lists

417-846A - ACCUSHOT YP8R-16TR

Callout

20

21

22

23

16

17

18

19

--

24

13

14

15

--

--

11

--

25

Callout Part Number Part Description

19

20

21

22

--

16

17

18

23

--

24

--

11

--

12

13

14

15

417-554L

417-785V

417-820S

115203-003

115204-001

417-690D

417-692D

417-911M

800-060C

800-112C

802-017C

803-014C

803-043C

804-012C

804-013C

806-192C

823-471C

858-708C

417-847A - ACCUSHOT YP8R-0830

YP8R HYD LIQ FERT

ACCUSHOT BLADE SEPARATOR

ACCUSHOT WETBOOM 16R15

ACCUSHOT VALVE 18CH EXT 048

ACCUSHOT SEED SENSOR T HARN 48

ACCUSHOT 8R CONTROLLER MNT PLT

WETBOOM OFFSET PLT

MANUAL ACCUSHOT INSTALL YP8R

CABLE TIE .19X14.25 3DIA 50

CABLE TIE .19X7.25 1.75D 50

HHCS 3/8-16X1 GR5

NUT HEX 3/8-16 PLT

NUT HEX WHIZ 5/16-18 PLT

WASHER FLAT 3/8 SAE PLT

WASHER LOCK SPRING 3/8 PLT

U-BOLT 5/16-18X1 1/2X2 1/2

ACCUSHOT YP8R BASE ELEC

DECAL ACCUSHOT CONTROLLER

Part Number

417-554L

417-785V

417-817S

115203-005

115204-001

417-690D

417-692D

417-911M

800-060C

800-112C

802-017C

803-014C

803-043C

804-012C

804-013C

806-192C

823-471C

858-708C

Part Description

YP8R HYD LIQ FERT

ACCUSHOT BLADE SEPARATOR

ACCUSHOT WETBOOM 08R30

ACCUSHOT VALVE 12CH EXT 048

ACCUSHOT SEED SENSOR T HARN 48

ACCUSHOT 8R CONTROLLER MNT PLT

WETBOOM OFFSET PLT

MANUAL ACCUSHOT INSTALL YP8R

CABLE TIE .19X14.25 3DIA 50

CABLE TIE .19X7.25 1.75D 50

HHCS 3/8-16X1 GR5

NUT HEX 3/8-16 PLT

NUT HEX WHIZ 5/16-18 PLT

WASHER FLAT 3/8 SAE PLT

WASHER LOCK SPRING 3/8 PLT

U-BOLT 5/16-18X1 1/2X2 1/2

ACCUSHOT YP8R BASE ELEC

DECAL ACCUSHOT CONTROLLER

Parts Lists

Qty.

4

16

8

4

1

25

75

4

8

1

3

1

16

1

1

16

1

8

Qty.

16

8

4

8

25

75

4

4

1

3

8

1

8

1

1

8

1

1

12/06/16 11

AccuShot Fertilizer System

417-554L - YP8R HYD LIQ FERT

Callout

37

38

39

40

33

34

35

36

26

27

28

29

30

31

32

45

46

47

48

41

42

43

44

Part Number

401-901H

401-902H

407-996K

417-550K

417-551S

417-552H

417-553S

800-123C

800-125C

802-007C

803-181C

803-193C

804-009C

804-010C

806-102C

806-139C

829-010C

829-147C

830-028C

830-042C

830-123C

990-081R

990-181R

417-785V - ACCUSHOT BLADE SEPARATOR

Part Description

RH LIQUID TANK SUPT WELD

LH LIQUID TANK SUPT WELD

TANK ASSY, 200 GAL

YP8R HYD FERT PUMP KIT

YP8R RIGHT TANK FILL ASSEMBLY

4IN HOSE LOOP GUIDE

YP8R LEFT TANK FILL ASSEMBLY

CLAMP WRM DRV #16 SS (.68-1.5)

CLAMP WRM DRV#28 SS(1.31-2.25)

HHCS 5/16-18X3/4 GR5

NUT HEX FLANGE LOCK 3/4-10 PLT

NUT HEX FLANGE 1/2-13 GR G PLT

WASHER LOCK SPRING 5/16 PLT

WASHER FLAT 5/16 USS PLT

U-BOLT 3/4-10 CORNER 7 SQ

U-BOLT 1/2-13 CORNER 5 X 7

VALVE - 3/4FNPT BALL POLYPROP

VALVE BALL 3/4HB 3/4MNPT POLY

TEE 3/4FNPT POLYPROP

AD 3/4MNPT POLYPROP

EL 3/4MNPT X 3/4HB POLYPROP

HOSE 3/4 ID 200PSI EPDM

HOSE 1 1/2 ID 250PSI EPDM

Callout

--

--

--

49

50

Part Number

417-776H

828-066C

829-151C

830-464C

830-465C

417-817S - ACCUSHOT WETBOOM 08R30

Part Description

ACCUSHOT SCRAPER SEPARATOR

NOZZLE SOLIDSTRM 1/8MEG-0008

1/8FNPT SS CHECK VALVE 7PSI

3/8PTC LOCKING CLIP

ELBOW PTC 3/8 X 3/8

Callout

--

--

--

--

51

52

--

Part Number

115200-103

417-658D

417-786V

417-792H

830-022C

830-029C

830-127C

Part Description

ACCUSHOT VALVE HARNESS 08R30

ACCUSHOT WETBOOM TUBE 04R30

SOLENOID NOZZLE BODY

WETBOOM RISER PIPE

PL 1MNPT POLYPROP

TEE 1FNPT POLYPROP

EL 1MNPT X 1HB POLYPROP

Parts Lists

Qty.

8

4

4

4

8

4

4

8

1

1

2

1

2

2

2

2

2

30 ft

14 ft

4

1

1

1

Qty.

1

1

1

2

1

Qty.

2

2

3

1

1

2

8

12 Great Plains | 417-911M

AccuShot Fertilizer System

417-820S - ACCUSHOT WETBOOM 16R15

Callout

--

--

--

53

54

--

--

Part Number

115200-002

417-669D

417-786V

417-792H

830-022C

830-029C

830-127C

417-786V - SOLENOID NOZZLE BODY

Part Description

ACCUSHOT VALVE HARNESS 16R15

ACCUSHOT WETBOOM TUBE 08R15

SOLENOID NOZZLE BODY

WETBOOM RISER PIPE

PL 1MNPT POLYPROP

TEE 1FNPT POLYPROP

EL 1MNPT X 1HB POLYPROP

Callout

--

--

--

55

--

--

Part Number

417-644D

115290-111

829-152C

830-426C

830-464C

832-051C

Part Description

TUBING 3/8ODX.075WLX78 NYLON

ACCUSHOT VALVE ASY ARAG 12W HS

NZZL BD 1IN WET BOOM NO CHK

AD 1/4MNPT X 3/8OD TUBE PTC

3/8PTC LOCKING CLIP

NOZZLE CAP QUICK X 90X1/4 FNPT

823-471C - ACCUSHOT YP8R BASE ELEC

Callout

56

57

58

59

60

61

Part Number

115100-181

115201-004

115205-006

115206-001

115400-001

116301-001

Part Description

ACCUSHOT CONTROLLER 18CH

ACCUSHOT POWER HARNESS 450

ACCUSHOT ACC HARN YP8R

ACCUSHOT GPS SENSOR MAG MNT

ACCUSHOT CAB KIT

ACCUSHOT PRESSURE SENSOR

Parts Lists

Qty.

1

1

1

1

1

1

Qty.

2

3

1

1

2

8

2

Qty.

1

1

1

1

1

1

12/06/16 13

AccuShot Fertilizer System Parts Lists

14 Great Plains | 417-911M

Great Plains, Mfg.

1525 E. North St.

P.O. Box 5060

Salina, KS 67402

advertisement