SOFTENERS AND IRON FILTERS
Model 5600 SXT-User Programming Chart
Time of Day
FROM SERVICE MODE:•
To set Time of the Day push and hold
(*Not both Up and Down Buttons)
Display is TD (Time of Display) → Press
display time.
UP
UP
or
or
DOWN
button for 5 seconds
DOWN
button to adjust the
Press Extra Cycle button to resume normal operation
Model 5600 SXT -User Programming Chart
FROM SERVICE MODE:•
To set user programming push and hold
UP
and
DOWN
buttons for 5
seconds, and the time of day is NOT set to 12:01 PM.
Display is DO (DAY OVERRIDE) → [factory default setting: OFF]. Press UP/DOWN
buttons to adjust the setting.
↓
Extra Cycle
Button
↓
Display is RT (REGENRATION TIME) ([default:
For Iron Filters - 11:00 P.M.
For Softeners – 2:00 A.M.]
Press UP/DOWN buttons to adjust the time.
↓
Extra Cycle
Button
↓
Display is H (FEED WATER HARNESS) [grains per gallons default: Softeners - 15].
Iron content ppm per gallon default: Iron Filters - 20
Press UP/DOWN buttons to adjust the value. NOT AVAILABLE IF THE VALVE TYPE
IS SET TO FILTER IN MASTER PROGRAAMING.
↓
Extra Cycle
Button
↓
Display is RC (FIXED RESERVE CAPACITY) [Fixed reserve capacity in gallons default:
0]. Press UP/DOWN buttons to adjust the value.
↓
Extra Cycle
Button
42133
↓
Display is CD (CURRENT DAY OF THE WEEK). Press UP/DOWN buttons to adjust the
current day of the week. ONLY AVAILABLE IF DAY OF THE WEEK CONTROL IS
ON IN MASTER PROGRAAMING
Model 5600 SXT- Master Programming Chart
FROM SERVICE MODE:-
•
To enter master programming mode, set the Time of Day display to 12:01 P.M.
↓
Extra Cycle
Button
↓
Press and hold
UP
and
DOWN
buttons together until the programming icon
replaces the service icon
Display is DF (DISPLAY FORMAT) → Unit of measure for volume and display format for
time [Factory Default Setting: GAL]. Press UP/DOWN buttons to adjust the settings.
↓
Extra Cycle
Button
↓
Display is VT (VALVE TYPE) → type of valve setting [Factory Setting: St1b (Standard
Downflow/Upflow, Single Backwash]. Press UP/DOWN buttons to adjust the settings.
↓
Extra Cycle
Button
↓
Display is CT (Control Type)→
→ type of regeneration [Factory Setting: Fd (Meter Delayed)].
Press UP/DOWN buttons to adjust the settings.
↓
Extra Cycle
Button
↓
Display is NT (Number of Tanks)→
→ [Factory Default Setting: 1]. Do not change the setting.
↓
Extra Cycle
Button
↓
Display is UNIT CAPACITY → Capacity in grains for softeners and in ppm per gallon for iron
filters.
[Factory Default Setting: Refer to User
Manual].
Press UP/DOWN buttons to adjust the value.
↓
Extra Cycle
Button
↓
Display is H (WATER HARDNESS) → Grains per Gallon for softener and ppm per gallon of
iron for iron filters will appear [factory default setting grains per gallons for Softeners – 15gpg
Iron content in ppm per gallon for Iron Filters – 20ppm].
Press UP/DOWN buttons to adjust the value.
↓
Extra Cycle
Button
↓
Display is RS (RESERVE SELECTION) → Type of reserve [Factory Default Setting: RC
(Fixed Reserve Capacity)]. Press UP/DOWN buttons to adjust the setting.
↓
Extra Cycle
Button
↓
Display is RC (FIXED RESERVE CAPACITY) → Reserve capacity in gallons [Factory
Default Setting: 0]. Press UP/DOWN buttons to adjust the value.
↓
Extra Cycle
Button
↓
Display is DO (DAY OVERRIDE) → [factory default setting: OFF]. Press UP/DOWN buttons
to adjust the setting.
↓
Extra Cycle
Button
↓
Display is RT (REGENRATION TIME) ([default: For Iron Filters – 11:00 P.M.
For Softeners – 2:00 A.M.]
Press UP/DOWN buttons to adjust the time.
↓
Extra Cycle
Button
↓
Display is BW (BACKWASH)→
→ [Factory Setting: For Iron Filter and Softener10 (10 minutes)
For Chemical Free Iron Filters 6 (6 minutes)
]. Press UP/DOWN buttons to adjust the time.
↓
Extra Cycle
Button
↓
Display is BR (BRINE RINSE) →[Factory Setting:
For Chemical Free Iron Filters 0 (0 minutes)
For Iron Filters 50 (50 minutes)
For Softeners 60 (60 minutes)]
Press UP/DOWN buttons to adjust the time.
↓
Extra Cycle
Button
↓
Display is RR (RAPID RINSE) → [Factory Setting:
For Softeners and Iron Filters - 10 (10 minutes)
For Chemical Free Iron Filters – 4 (4 minutes)
]. Press UP/DOWN buttons to adjust the time.
↓
Extra Cycle
Button
↓
Display is BF (BRINE FILL)→
→ [Factory default setting: Refer to User Manual].
Press UP/DOWN buttons to adjust the time.
↓
Extra Cycle
Button
↓
Display is D (DAY OF WEEK) →used to set the day of week in which the regeneration should
occur [Factory Setting: OFF]. Press UP/DOWN buttons to adjust the setting. ONLY
AVAILABLE IF CONTROL TYPE IS SET TO DAY OF WEEK SETTING.
↓
Extra Cycle
Button
↓
Display is CD (CURRENT DAY) → used to set the current day of week in which the
regeneration should occur Press UP/DOWN buttons to adjust the setting. ONLY AVAILABLE
IF CONTROL TYPE IS SET TO DAY OF WEEK SETTING.
↓
Extra Cycle
Button
↓
Display is FM (FLOW METER TYPE)→
→ [Factory Setting: t0.7].Do not change this setting.
↓
Extra Cycle
Button
↓
RETURN TO SERVICE
Model 5600 SXT-Diagnostics Chart
To enter the diagnostic mode, push and hold
UP
and
Extra Cycle
Button
button for 5 seconds.
Display is FR (CURRENT FLOW RATE)→
→ display current flow rate in gallons per minutes.
↓
UP
↓
Display is PF (PEAK FLOW RATE)→
→ display peak flow rate in gallons per unit since the last
regeneration cycle.
↓
UP
↓
Display is HR (HOURS IN SERVICE)→
→ display to view the hours in service since the last
regeneration cycle.
↓
UP
↓
Display is VU (VOLUME USED) →display the volume in gallons used since the last
regeneration cycle.
↓
UP
↓
Display is RC (RESERVE CAPACITY)→
→display the reserve capacity in gallons.
↓
UP
↓
Display is SV (SOFTWARE VERSION)→
→display the software version
↓
Extra Cycle
Button
↓
End of Diagnostics
8/7/08
FILTERS
Model 5600 SXT-User Programming Chart
Time of Day
FROM SERVICE MODE:•
To set Time of the Day push and hold
(*Not both Up and Down Buttons)
Display is TD (Time of Display) → Press
display time.
UP
UP
or
or
DOWN
button for 5 seconds
DOWN
button to adjust the
Press Extra Cycle button to resume normal operation
Model 5600 SXT -User Programming Chart
FROM SERVICE MODE:•
To set user programming push and hold
UP
and
DOWN
buttons for 5
seconds, and the time of day is NOT set to 12:01 PM.
Display is DO (DAY OVERRIDE) → [factory default setting: OFF]. Press UP/DOWN
buttons to adjust the setting.
↓
Extra Cycle
Button
↓
Display is RT (REGENRATION TIME) ([default: 11:00 P.M.]. Press UP/DOWN buttons
to adjust the time.
↓
Extra Cycle
Button
↓
Display is RC (FIXED RESERVE CAPACITY) [Fixed reserve capacity in gallons default:
0]. Press UP/DOWN buttons to adjust the value.
↓
Extra Cycle
Button
↓
Display is CD (CURRENT DAY OF THE WEEK). Press UP/DOWN buttons to adjust the
current day of the week. ONLY AVAILABLE IF DAY OF THE WEEK CONTROL IS
ON IN MASTER PROGRAAMING
Model 5600 SXT- Master Programming Chart
FROM SERVICE MODE:-
•
To enter master programming mode, set the Time of Day display to 12:01 P.M.
↓
Extra Cycle
Button
↓
Press and hold
UP
and
DOWN
buttons together until the programming icon
replaces the service icon
Display is DF (DISPLAY FORMAT) → Unit of measure for volume and display format for
time [Factory Default Setting: GAL]. Press UP/DOWN buttons to adjust the settings.
↓
Extra Cycle
Button
↓
Display is VT (VALVE TYPE) → type of valve setting [Factory Setting: Fltr (Filter)]. Press
UP/DOWN buttons to adjust the settings.
↓
Extra Cycle
Button
↓
Display is CT (Control Type)→
→ type of regeneration [Factory Setting: Fd (Meter Delayed)].
Press UP/DOWN buttons to adjust the settings.
↓
Extra Cycle
Button
↓
Display is NT (Number of Tanks)→
→ [Factory Default Setting: 1]. Do not change the setting.
↓
Extra Cycle
Button
↓
Display is UNIT CAPACITY → Capacity in gallons. [Factory Default Setting: 10000 gallons]
].
Press UP/DOWN buttons to adjust the value.
↓
Extra Cycle
Button
↓
Display is RS (RESERVE SELECTION) → Type of reserve [Factory Default Setting: RC
(Fixed Reserve Capacity)]. Press UP/DOWN buttons to adjust the setting.
↓
Extra Cycle
Button
↓
Display is RC (FIXED RESERVE CAPACITY) → Reserve capacity in gallons [Factory
Default Setting: 0]. Press UP/DOWN buttons to adjust the value.
↓
Extra Cycle
Button
↓
Display is DO (DAY OVERRIDE) → [factory default setting: OFF]. Press UP/DOWN buttons
to adjust the setting.
↓
Extra Cycle
Button
↓
Display is RT (REGENRATION TIME) ([default: 11:00 P.M.]
Press UP/DOWN buttons to adjust the time.
↓
Extra Cycle
Button
↓
Display is BW (BACKWASH)→
→ [Factory Setting: 6 (6 minutes)]. Press UP/DOWN buttons to
adjust the time.
↓
Extra Cycle
Button
↓
Display is BD (BRINE DRAW) →[Factory Setting: 0 (0 minutes)
Press UP/DOWN buttons to adjust the time.
↓
Extra Cycle
Button
↓
Display is RR (RAPID RINSE) → [Factory Setting: 4 (4 minutes)]. Press UP/DOWN buttons to
adjust the time.]
Press UP/DOWN buttons to adjust the time.
↓
Extra Cycle
Button
↓
Display is D (DAY OF WEEK) →used to set the day of week in which the regeneration should
occur [Factory Setting: OFF]. Press UP/DOWN buttons to adjust the setting. ONLY
AVAILABLE IF CONTROL TYPE IS SET TO DAY OF WEEK SETTING.
↓
Extra Cycle
Button
↓
Display is CD (CURRENT DAY) → used to set the current day of week in which the
regeneration should occur Press UP/DOWN buttons to adjust the setting. ONLY AVAILABLE
IF CONTROL TYPE IS SET TO DAY OF WEEK SETTING.
↓
Extra Cycle
Button
↓
Display is FM (FLOW METER TYPE)→
→ [Factory Setting: t0.7].Do not change this setting.
↓
Extra Cycle
Button
↓
RETURN TO SERVICE
Model 5600 SXT-Diagnostics Chart
To enter the diagnostic mode, push and hold
UP
and Extra Cycle
Button
button for 5 seconds.
Display is FR (CURRENT FLOW RATE)→
→ display current flow rate in gallons per minutes.
↓
UP
↓
Display is PF (PEAK FLOW RATE)→
→ display peak flow rate in gallons per unit since the last
regeneration cycle.
↓
UP
↓
Display is HR (HOURS IN SERVICE)→
→ display to view the hours in service since the last
regeneration cycle.
↓
UP
↓
Display is VU (VOLUME USED) →display the volume in gallons used since the last
regeneration cycle.
↓
UP
↓
Display is RC (RESERVE CAPACITY)→
→display the reserve capacity in gallons.
↓
UP
↓
Display is SV (SOFTWARE VERSION)→
→display the software version
↓
Extra Cycle
Button
↓
End of Diagnostics