advertisement
▼
Scroll to page 2
of 10
8/7/08 SOFTENERS AND IRON FILTERS Model 5600 SXT-User Programming Chart Time of Day FROM SERVICE MODE:• To set Time of the Day push and hold (*Not both Up and Down Buttons) Display is TD (Time of Display) → Press display time. UP UP or or DOWN button for 5 seconds DOWN button to adjust the Press Extra Cycle button to resume normal operation Model 5600 SXT -User Programming Chart FROM SERVICE MODE:• To set user programming push and hold UP and DOWN buttons for 5 seconds, and the time of day is NOT set to 12:01 PM. Display is DO (DAY OVERRIDE) → [factory default setting: OFF]. Press UP/DOWN buttons to adjust the setting. ↓ Extra Cycle Button ↓ Display is RT (REGENRATION TIME) ([default: For Iron Filters - 11:00 P.M. For Softeners – 2:00 A.M.] Press UP/DOWN buttons to adjust the time. ↓ Extra Cycle Button ↓ Display is H (FEED WATER HARNESS) [grains per gallons default: Softeners - 15]. Iron content ppm per gallon default: Iron Filters - 20 Press UP/DOWN buttons to adjust the value. NOT AVAILABLE IF THE VALVE TYPE IS SET TO FILTER IN MASTER PROGRAAMING. ↓ Extra Cycle Button ↓ Display is RC (FIXED RESERVE CAPACITY) [Fixed reserve capacity in gallons default: 0]. Press UP/DOWN buttons to adjust the value. ↓ Extra Cycle Button 42133 ↓ Display is CD (CURRENT DAY OF THE WEEK). Press UP/DOWN buttons to adjust the current day of the week. ONLY AVAILABLE IF DAY OF THE WEEK CONTROL IS ON IN MASTER PROGRAAMING Model 5600 SXT- Master Programming Chart FROM SERVICE MODE:- • To enter master programming mode, set the Time of Day display to 12:01 P.M. ↓ Extra Cycle Button ↓ Press and hold UP and DOWN buttons together until the programming icon replaces the service icon Display is DF (DISPLAY FORMAT) → Unit of measure for volume and display format for time [Factory Default Setting: GAL]. Press UP/DOWN buttons to adjust the settings. ↓ Extra Cycle Button ↓ Display is VT (VALVE TYPE) → type of valve setting [Factory Setting: St1b (Standard Downflow/Upflow, Single Backwash]. Press UP/DOWN buttons to adjust the settings. ↓ Extra Cycle Button ↓ Display is CT (Control Type)→ → type of regeneration [Factory Setting: Fd (Meter Delayed)]. Press UP/DOWN buttons to adjust the settings. ↓ Extra Cycle Button ↓ Display is NT (Number of Tanks)→ → [Factory Default Setting: 1]. Do not change the setting. ↓ Extra Cycle Button ↓ Display is UNIT CAPACITY → Capacity in grains for softeners and in ppm per gallon for iron filters. [Factory Default Setting: Refer to User Manual]. Press UP/DOWN buttons to adjust the value. ↓ Extra Cycle Button ↓ Display is H (WATER HARDNESS) → Grains per Gallon for softener and ppm per gallon of iron for iron filters will appear [factory default setting grains per gallons for Softeners – 15gpg Iron content in ppm per gallon for Iron Filters – 20ppm]. Press UP/DOWN buttons to adjust the value. ↓ Extra Cycle Button ↓ Display is RS (RESERVE SELECTION) → Type of reserve [Factory Default Setting: RC (Fixed Reserve Capacity)]. Press UP/DOWN buttons to adjust the setting. ↓ Extra Cycle Button ↓ Display is RC (FIXED RESERVE CAPACITY) → Reserve capacity in gallons [Factory Default Setting: 0]. Press UP/DOWN buttons to adjust the value. ↓ Extra Cycle Button ↓ Display is DO (DAY OVERRIDE) → [factory default setting: OFF]. Press UP/DOWN buttons to adjust the setting. ↓ Extra Cycle Button ↓ Display is RT (REGENRATION TIME) ([default: For Iron Filters – 11:00 P.M. For Softeners – 2:00 A.M.] Press UP/DOWN buttons to adjust the time. ↓ Extra Cycle Button ↓ Display is BW (BACKWASH)→ → [Factory Setting: For Iron Filter and Softener10 (10 minutes) For Chemical Free Iron Filters 6 (6 minutes) ]. Press UP/DOWN buttons to adjust the time. ↓ Extra Cycle Button ↓ Display is BR (BRINE RINSE) →[Factory Setting: For Chemical Free Iron Filters 0 (0 minutes) For Iron Filters 50 (50 minutes) For Softeners 60 (60 minutes)] Press UP/DOWN buttons to adjust the time. ↓ Extra Cycle Button ↓ Display is RR (RAPID RINSE) → [Factory Setting: For Softeners and Iron Filters - 10 (10 minutes) For Chemical Free Iron Filters – 4 (4 minutes) ]. Press UP/DOWN buttons to adjust the time. ↓ Extra Cycle Button ↓ Display is BF (BRINE FILL)→ → [Factory default setting: Refer to User Manual]. Press UP/DOWN buttons to adjust the time. ↓ Extra Cycle Button ↓ Display is D (DAY OF WEEK) →used to set the day of week in which the regeneration should occur [Factory Setting: OFF]. Press UP/DOWN buttons to adjust the setting. ONLY AVAILABLE IF CONTROL TYPE IS SET TO DAY OF WEEK SETTING. ↓ Extra Cycle Button ↓ Display is CD (CURRENT DAY) → used to set the current day of week in which the regeneration should occur Press UP/DOWN buttons to adjust the setting. ONLY AVAILABLE IF CONTROL TYPE IS SET TO DAY OF WEEK SETTING. ↓ Extra Cycle Button ↓ Display is FM (FLOW METER TYPE)→ → [Factory Setting: t0.7].Do not change this setting. ↓ Extra Cycle Button ↓ RETURN TO SERVICE Model 5600 SXT-Diagnostics Chart To enter the diagnostic mode, push and hold UP and Extra Cycle Button button for 5 seconds. Display is FR (CURRENT FLOW RATE)→ → display current flow rate in gallons per minutes. ↓ UP ↓ Display is PF (PEAK FLOW RATE)→ → display peak flow rate in gallons per unit since the last regeneration cycle. ↓ UP ↓ Display is HR (HOURS IN SERVICE)→ → display to view the hours in service since the last regeneration cycle. ↓ UP ↓ Display is VU (VOLUME USED) →display the volume in gallons used since the last regeneration cycle. ↓ UP ↓ Display is RC (RESERVE CAPACITY)→ →display the reserve capacity in gallons. ↓ UP ↓ Display is SV (SOFTWARE VERSION)→ →display the software version ↓ Extra Cycle Button ↓ End of Diagnostics 8/7/08 FILTERS Model 5600 SXT-User Programming Chart Time of Day FROM SERVICE MODE:• To set Time of the Day push and hold (*Not both Up and Down Buttons) Display is TD (Time of Display) → Press display time. UP UP or or DOWN button for 5 seconds DOWN button to adjust the Press Extra Cycle button to resume normal operation Model 5600 SXT -User Programming Chart FROM SERVICE MODE:• To set user programming push and hold UP and DOWN buttons for 5 seconds, and the time of day is NOT set to 12:01 PM. Display is DO (DAY OVERRIDE) → [factory default setting: OFF]. Press UP/DOWN buttons to adjust the setting. ↓ Extra Cycle Button ↓ Display is RT (REGENRATION TIME) ([default: 11:00 P.M.]. Press UP/DOWN buttons to adjust the time. ↓ Extra Cycle Button ↓ Display is RC (FIXED RESERVE CAPACITY) [Fixed reserve capacity in gallons default: 0]. Press UP/DOWN buttons to adjust the value. ↓ Extra Cycle Button ↓ Display is CD (CURRENT DAY OF THE WEEK). Press UP/DOWN buttons to adjust the current day of the week. ONLY AVAILABLE IF DAY OF THE WEEK CONTROL IS ON IN MASTER PROGRAAMING Model 5600 SXT- Master Programming Chart FROM SERVICE MODE:- • To enter master programming mode, set the Time of Day display to 12:01 P.M. ↓ Extra Cycle Button ↓ Press and hold UP and DOWN buttons together until the programming icon replaces the service icon Display is DF (DISPLAY FORMAT) → Unit of measure for volume and display format for time [Factory Default Setting: GAL]. Press UP/DOWN buttons to adjust the settings. ↓ Extra Cycle Button ↓ Display is VT (VALVE TYPE) → type of valve setting [Factory Setting: Fltr (Filter)]. Press UP/DOWN buttons to adjust the settings. ↓ Extra Cycle Button ↓ Display is CT (Control Type)→ → type of regeneration [Factory Setting: Fd (Meter Delayed)]. Press UP/DOWN buttons to adjust the settings. ↓ Extra Cycle Button ↓ Display is NT (Number of Tanks)→ → [Factory Default Setting: 1]. Do not change the setting. ↓ Extra Cycle Button ↓ Display is UNIT CAPACITY → Capacity in gallons. [Factory Default Setting: 10000 gallons] ]. Press UP/DOWN buttons to adjust the value. ↓ Extra Cycle Button ↓ Display is RS (RESERVE SELECTION) → Type of reserve [Factory Default Setting: RC (Fixed Reserve Capacity)]. Press UP/DOWN buttons to adjust the setting. ↓ Extra Cycle Button ↓ Display is RC (FIXED RESERVE CAPACITY) → Reserve capacity in gallons [Factory Default Setting: 0]. Press UP/DOWN buttons to adjust the value. ↓ Extra Cycle Button ↓ Display is DO (DAY OVERRIDE) → [factory default setting: OFF]. Press UP/DOWN buttons to adjust the setting. ↓ Extra Cycle Button ↓ Display is RT (REGENRATION TIME) ([default: 11:00 P.M.] Press UP/DOWN buttons to adjust the time. ↓ Extra Cycle Button ↓ Display is BW (BACKWASH)→ → [Factory Setting: 6 (6 minutes)]. Press UP/DOWN buttons to adjust the time. ↓ Extra Cycle Button ↓ Display is BD (BRINE DRAW) →[Factory Setting: 0 (0 minutes) Press UP/DOWN buttons to adjust the time. ↓ Extra Cycle Button ↓ Display is RR (RAPID RINSE) → [Factory Setting: 4 (4 minutes)]. Press UP/DOWN buttons to adjust the time.] Press UP/DOWN buttons to adjust the time. ↓ Extra Cycle Button ↓ Display is D (DAY OF WEEK) →used to set the day of week in which the regeneration should occur [Factory Setting: OFF]. Press UP/DOWN buttons to adjust the setting. ONLY AVAILABLE IF CONTROL TYPE IS SET TO DAY OF WEEK SETTING. ↓ Extra Cycle Button ↓ Display is CD (CURRENT DAY) → used to set the current day of week in which the regeneration should occur Press UP/DOWN buttons to adjust the setting. ONLY AVAILABLE IF CONTROL TYPE IS SET TO DAY OF WEEK SETTING. ↓ Extra Cycle Button ↓ Display is FM (FLOW METER TYPE)→ → [Factory Setting: t0.7].Do not change this setting. ↓ Extra Cycle Button ↓ RETURN TO SERVICE Model 5600 SXT-Diagnostics Chart To enter the diagnostic mode, push and hold UP and Extra Cycle Button button for 5 seconds. Display is FR (CURRENT FLOW RATE)→ → display current flow rate in gallons per minutes. ↓ UP ↓ Display is PF (PEAK FLOW RATE)→ → display peak flow rate in gallons per unit since the last regeneration cycle. ↓ UP ↓ Display is HR (HOURS IN SERVICE)→ → display to view the hours in service since the last regeneration cycle. ↓ UP ↓ Display is VU (VOLUME USED) →display the volume in gallons used since the last regeneration cycle. ↓ UP ↓ Display is RC (RESERVE CAPACITY)→ →display the reserve capacity in gallons. ↓ UP ↓ Display is SV (SOFTWARE VERSION)→ →display the software version ↓ Extra Cycle Button ↓ End of Diagnostics
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project