advertisement
Laserscan
Fast scanning DMX lasers with remote control
M A N U A L V E R S I O N 1 .
0
15 - 11 - 11
Kam Laserscan 180 RBP | Kam Laserscan 120 GBC | Kam Laserscan 170 RGY
Due to continuous product development, please ensure that you have downloaded the latest instruction manual for this product from the Kam website at www.kam.co.uk
For the latest updates and information on the entire Kam range visit:
www.kam.co.uk
Kam products are manufactured by: Lamba plc, Unit 1, Southfields Road, Dunstable, Bedfordshire, United Kingdom LU6 3EJ
Telephone: (+44) (0)1582 690600 • Fax: (+44) (0)1582 690400 • Email: [email protected] • Web: www.lambaplc.com
If this product is ever no longer functional please take it to a recycling plant for environmentally friendly disposal.
Due to continuous product development, specifications and appearance are subject to change.
© Copyright Lamba plc 2011. E&OE.
Thank you for purchasing this KAM product, we are sure that it will serve you for many years to come.
To optimise the performance of this product, please read these operating instructions carefully to familiarise yourself with the basic operations of this unit. After you have read the instructions, please retain them for future reference.
This unit has been tested at the factory before being shipped to you.
To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or moisture. To prevent a fire hazard, do not expose the unit to any naked flame sources. Unplug this apparatus during lightning storms or if it is unlikely to be used for long periods of time.
When installing the unit, please ensure you leave enough space around the unit for ventilation. Slots and openings in the unit are provided for ventilation to ensure reliable operation of the product and to protect it from overheating. To prevent fire hazard, the openings should never be blocked or covered.
Always handle the power cable by the plug. Never pull out the plug by pulling on the cable. Never touch the power cable when your hands are wet as this could cause an electric shock. Do not tie a knot in the cable. The power cable should be placed such that it is not likely to be stepped on. A damaged power cable can cause a fire or give you an electrical shock. Check the power cord periodicaly, if you ever find that it is damaged, replace it before using the unit again. Contact your retailer for a replacement.
The voltage of the available power supply differs according to country or region. Be sure that the power supply voltage of the area where this unit is to be used meets the required written on the unit.
The lightning flash symbol inside a triangle is intended to alert the user to the presence high voltage within the unit’s
enclosure that may be of sufficient power to constitute a risk of electrical shock to persons.
Caution: to prevent the risk of electric shock, do not attempt to open the unit. No user-serviceable parts inside. Refer all servicing to qualified service personnel.
The exclamation mark inside a triangle is intended to alert the user to the presence of important operating and maintenance instructions in the literature accompanying the appliance.
Any modification carried out on the unit may invalidate the unit’s warranty.
If applicable, only use the stand, tripod or bracket specified or sold with the apparatus.
Select the installation location of your unit carefully. Avoid placing it in direct sunlight or locations subject to vibration and excessive dust. Do not use the unit where there are extremes in temperature (below 41ºF / 5ºC or exceeding 95ºF / 35ºC).
Unpacking and safety: Please unpack your new product carefully, your new product should reach you in perfect condition. Please check that no damage has occurred during transit. If any damage is found, do not operate your unit. Please contact the retailer you purchased it from immediately. If there is any damage to the mains cable do not use the device. Always disconnect the unit from the mains supply when carrying out any servicing or cleaning of the unit.
The serial number for this equipment should be located on the rear or underside of the unit. Please make a note of this number as you will need it for your warranty, it is a good idea to keep a copy of the serial number for your own records.
Unpacking Instructions
CAUTION! Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that all parts are present and have been received in good condition. Notify the shipper immediately and retain packing material for inspection if any parts appear damage from shipping or the package itself shows signs of mishandling. Save the package and all packing materials.
In the event that a fixture must be returned to the retailer, it is important that the fixture be returned in the original box and packing.
Contents
1 x laser, 2 x keys (for key switch), 1 x interlock connector, 1 x power cord, 1 x user manual, 1 x laser safety guide
Power Supply
Cable (EU)
Brown
Light Blue
Cable (US)
Black
White
Pin
Live
Neutral
International
L
N
Yellow/Green Green Earth
DMX-512 connection between fixtures
The fixture is equipped with 3-pin XLR sockets for DMX input and output. The sockets are wired in parallel. Only use a shielded twisted-pair cable designed for 3-pin XLR-plugs and connectors in order to connect the controller with the fixture or one fixture with another.
XLR-connection
Building a serial DMX-chain
• If you are using a standard DMX-controller, you can connect the DMX-output of the controller directly with the DMX-input of the first fixture in the DMX-chain. If you wish to connect DMX-controllers with other XLR-outputs, you need to use adapter cables. (DMX controller not supplied).
• Connect the DMX-output of the first fixture in the DMX-chain with the DMX-input of the next fixture. Always connect output with the input of the next fixture until all fixtures are connected.
• If you use a controller with 5 pins DMX connector, you need to use a 5 to 3 pins adapter.
• The DMX output and input connectors are pass-through to maintain the DMX circuit, when power is disconnected to the unit.
• Each fixture needs to have a DMX address to receive the data from the controller. The DMX address number which could be read from rear panel of each fixture is between 000~511.
Proper laser set up & usage
This fixture has been designed to be hung. It is recommended for safety purposes, your lighting effect are properly mounted using a suitable hanging clamp and safety cable. Items appropriate for safe and effective mounting are easily sourced from your lighting vendor.
International laser safety regulations require that lasers must be operated in the fashion illustrated below, with a minimum of 3 meters (9.8 ft) of vertical separation between the floor and the lowest laser light vertically. Additionally, 2.5 meters of horizontal separation is required between laser light and audience or other public spaces.
Front Panel
1. Laser output – Laser output aperture
2. Power – Main power indicated LED. Red is ON
3. Music/IR – Synchronize to detected music signal / IR indicator
(flashing for each signal received)
4. IR – Infrared remote receiver
5. Cooling fan – cooling the unit. Never cover this fan outlet
6. Hanging bracket – 2 knobs on each side to fasten the unit
and a mounting hole to fix a mounting clamp.
Rear Panel
7. Switch – Switch on and off the power
8. Mains input – with socket and intergrated fuse holder
9. Key switch
10. Interlock – For emergency laser stop
11. LED function display
12. Safety eye – Attach the safety cable
13. DMX input - 3 PIN Male XLR
14. DMX output – 3 PIN Female XLR
Operating Mode
When the laser is powered on, the LCD monitor on rear panel shows the current operating standalone mode, DMX address or
Slave mode. With help of the LCD control panel, it is very easy to set and change the operating mode of the laser. The next time the laser is powered on it will show the last setting used before the laser was powered off.
Mode Option, to choose the operating mode of laser.
Confirmation, to confirm the selected mode.
UP/DOWN, to change operating mode, parameter or DMX address.
Operation
Display
Aut
Au1
Au2
Au3
Stand alone mode pre-programmed effect
Automatic show with 3 colours
Automatic show with single colour 1
Automatic show with single colour 2
Automatic show with single colour 3
Sou
So1
So2
So3
Sound activated show with 3 colours
Sound activated show with single colour 1
Sound activated show with single colour 2
Sound activated show with single colour 3
AUP
SOP
ATTENTION! In pre-programmed standalone MUSIC SHOW mode, the laser beam will be blank-out in 3 seconds without
AUDIO/MIC activated signal.
DMX MODE
Auto running pattern effect show
Sound activated pattern effect show
• Press FUNC to enter the MODE selection
• The LED panel will show 001 for DMX mode
• Press ENTER to confirm the setting
Now the laser is working in DMX mode.
Use the up/down buttons to select the DMX address.
Note: In DMX MODE, once the DMX cable is connected to the laser and DMX controller, the DMX LED in front panel of laser will be ON.
DMX address
Each unit uses 17 DMX channels. To select the desired DMX address press the menu button until DMX mode is displayed, then press the enter button to access the DMX channel menu.
This example shows how to set the start address to 001 but use the same formula to set address at different numbers.
At the top of the menu address #*** is displayed, use the up down buttons until 001 is shown and press the enter button to confirm.
Now this unit has the DMX starting address of 001. If all units are to be controlled exactly the same set all units to address 001.
If individual control of units is required each unit must have its own starting address and must be at least 17 channels apart . None of the channels must cross. E.g. Set the first unit to 001 the second unit to 018 and so on each unit is 17 channels apart. Now the
DMX controller will control all the units seperatley.
SLAVE MODE
• Press FUNC to enter the MODE selection
• Use the up/down buttons to select SLA for Slave mode
• Press ENTER to confirm the setting
Now the laser is working in SLAVE MODE. Connect the MASTER laser with several SLAVE lasers using a DMX cable. The SLAVE lasers will produce exactly the same laser show as MASTER laser.
REM MODE (Remote Optional)
• Press FUNC to enter the MODE selection
• Use the up/down buttons to select REM for Remote mode
• Press ENTER to confirm the setting
Please check Remote Instruction for remote control details.
Note: In any standalone mode (except REM and SLA), press ON/OFF for 2 seconds to activate the remote function.
PATTERN MIRROR REVERSE SETTING
• Press FUNC to enter the MODE selection
• Use the up/down buttons to set the LED display to match Fig A.
• Press ENTER to confirm the setting.
FIG. A >
Using the up/down buttons, set the LED display to match
FIG. B >
Fig. B. This will rotate the graphic in the X direction.
• Using the up/down buttons, set the LED display to match
Fig. C. This will flip the graphic in the Y direction.
FIG. C >
Remote Instruction
Button Function
ON/OFF
Description
In REM mode, to turn ON/OFF laser. In any stand alone mode, except for SLA mode, pressing this button for 2 seconds will activate the REM mode.
Auto Auto running slow
Music
Sound Activated show. The blue music LED indicator is flashing when sound signal is detected.
Sound sensitivity
In Sound Activated Mode, press Music + B + “1-9” to adjust the sensitivity setting. “9” is the most sensitive.
Colour changing Cycle through the colours
Pattern changing
To show and change patterns
Fixed pattern Choose favourite pattern from 1 to 48
Pattern repeat Last pattern and current pattern cycle repeating
DMX Channels Chart
Channel
CH 1 - MODE
CH 2 - GROUP
CH 3 - PATTERN
CH 4 - COLOR
CH 5 - CLIPING
CH 6 - ZOOMING
CH7 - ZOOM SPEED
CH 8 - Y AXIS ROLLING
CH 9 - ROLL SPEED
CH 10 - X AXIS ROLLING
CH 11 - ROLL SPEED
CH 12 - Z AXIS ROLLING
CH 13 - ROLL SPEED
CH 14 - X AXIS MOVING
CH 15 - MOVE SPEED
CH 16 - X AXIS MOVING
CH 17 - MOVE SPEED
Value Function
000-020 Laser OFF
021-040 AUT
041-060 AU1
061-080 AU2
081-100 AU3
101-120 SOU
121-140 SO1
141-160 SO2
161-180 SO3
181-200 AUP
201-220 SOP
221-255 DMX MODE
000-051 1 Group Patterns.
052-103 2 Group Patterns
104-055 3 Group Patterns
156-207 4 Group Patterns
208-255 5 Group Patterns
000-255 Every 16 for 1 group, total 80 patterns.
000-015 Original
016-031 Colour 1
032-047 Colour 2
048-063 Colour 3
064-111 Colour Rolling
112-159 Colour Jumping
160-207 Colour Moving
208-255 Strobing
000 Full pattern without clipping
001-127 0%~99% fixed pattern clipped
128-255 Clipping Speed
000-127 100%-5% fixed pattern zoomed
128-169 Zooming IN
170-209 Zooming OUT
210-255 Alternately Zooming
000-255 Fast to Slow
000-127 0 -359 degree fixed Y axis rolled
128-191 Clockwise rolling
192-255 Anticlockwise rolling
000-255 Fast to Slow
000-127 0 -359 degree fixed X axis rolled
128-191 Clockwise rolling
192-255 Anticlockwise rolling
0-255 Fast to Slow
000-127 0 -359 degree fixed Z axis rolled
128-191 Clockwise rolling
192-255 Anticlockwise rolling
0-255 Fast to Slow
000-127 128 different fixed position on X axis
128-191 Clockwise moving
192-255 Anticlockwise moving
0-255 Fast to Slow
000-127 128 different fixed position on Y axis
128-191 Clockwise moving
192-255 Anticlockwise moving
0-255 Fast to Slow
SPECIFICTAIONS
Mains Input:
Fuse:
Total Power:
X/Y Axis Beam Angle:
Music Control:
Laser Power (per unit):
AC100~240V, 50/60Hz
250V /1A Slow Blow (20mm Glass)
13w
±20°
Audio / Sound Activated
RGY: 120mW Red / 50mW Green
Laser Classification:
Laser Safety Standard:
Condition Temperature:
DMX Connections:
DMX Channels:
Dimensions:
RBP: 100mW Red / 80mW Blue
GBC: 40mW Green / 80mW Blue
Class 3B
EN60825-1 2007
190 x 80 x 170mm
3 pins XLR Male/Female
Max 17 channels
190 x 80 x 170mm
1.5Kg
Nett Weight:
Features
Stunning fast scanning three colour lasers
Full DMX512 operation
17 DMX channels
Sound-to-Light operation via built-in mic
Auto and Master/Slave modes
Comes with IR remote control
LED control panel display
Tough metal chassis
Adjustable metal hanging bracket
Safety chain loop
Safety key On/Off lock
Mains fused IEC
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project