REGIS T – Standalone, access or time and attendance controller

REGIS T – STANDALONE, ACCESS or TIME AND

ATTENDANCE CONTROLLER

The Regis is a controller with built-in proximity card reader and 7”

LCD capacitive touch screen display. It is designed for residential and business buildings, offices, shops, etc. The controller can have

125kHz or 13.56MHz reading frequency.

As a standalone controller, the entire set-up procedure is carried out with master card or code. User cards and codes can either be registered or deleted. The controller allows access for up to 500 users (1 master card + 500 user cards or codes).

As an access controller, the entire set-up procedure is carried out with the software. The controller allows access for up to 30000 users and saves 100000 events. If you bought the controller in time and attendance kit, then inputs and outputs cannot be controlled.

It can also be used as a Wiegand 26-bit reader, if needed.

The SDK is also available for this controller. If a user or software producer wants to develop its own application, please contact us.

TECHNICAL DATA

REGIS T

REGIS T-1-9-NET reading frequency

REGIS T-1-9-NET reading distance

REGIS T-1-9-NET current consumption in standby mode

125kHz

Up to 15cm

300mA

REGIS T-3-9-NET reading frequency

REGIS T-3-9-NET reading distance

REGIS T-3-9-NET current consumption in standby mode

13.56MHz

Up to 7cm

330mA

Dimensions (mm)

Protection

Operating voltage

Operating temperature

Connector

210x150x35 (WxHxD)

IP21

From 9V to 14V DC

From -20°C to 60°C

2x 8pin, 1x ethernet

Display

Tamper

Display resolution

Humidity

Memory

TFT - capacitive touch

Accelerometer

800 x 480

10-80%, non condensing

Inputs

Outputs

Clock

Communication

500 or 30000 cards or codes

100000 events

Door status

Push button

Transistor output for el. strike

0.5A

Real time clock, battery backup

(max. ten hours)

RS485

Ethernet

Keypad Configurable buttons

Selectable colors

*if Regis T is in Spider mode, the same data applies

Power supply

The controller need’s external power supply to operate. The Spider

W40 power supply is sufficient to power two controllers and two

12V electric strikes or two 12V magnetic locks (0.5A). If you will use it as a standalone controller and low consumption electric strike (0.25A) you can use power supply Spider W5.

Voltage drops and cable signal interferences

When you connect the controller, use cable with a diameter of at least 0.22mm

2 . If the cable length exceeds 25m, use one twisted pair of UTP cables for the positive (+) pole and one for the negative (-) pole. The cable length between power supply and the controller should not exceed 50m.

Take into consideration that a 0.22mm

2 cable has a resistance of approximately 9 ohm per 100m. The power supply at the end of cable should be a minimum of 9V. If you are using el. strike, it is highly recommended that the voltage drop is calculated. At greater

or more should be used distances, a thicker cable of 0.5mm

2 wherever possible.

If the load is, for example, 0.5A (with el. strike) then, on the

0.22mm

2 cable voltage drop will be 4.5V at 100m. For the device with 60mA consumption, the voltage drop is 0.5V.

Reading distance depends on where the controller is installed. The presence of metal or interferences can significantly reduce the reading distance. DO NOT install the controller directly on metal surfaces and/or cover it with a metal cover.

It is not recommended to install controllers closer than 30cm from each other in any direction. Otherwise, it may result in inaccurate readings or, indeed, in the controller not reading at

all.

For the Regis T-3-9-NET to comply with EMC directives (CE), you have to put ferrite core on the cable as close to the controller as possible, making two turns!

CONNECTOR DESCRIPTION

Connectors are marked on the housing with 1 in 2. First contact on both connectors starts on the marked side (1 and 2)

CONNECTOR 1 – connection of power supply, el. strike...

Contact Description

1 9-14V DC

2 GND

Specification

Power supply

Ground

3

4

El. strike output

Alarm output

Max. 0,5A

Active = GND

Max. 0,5A

Active = GND

Active = GND 5

6

7

Door status switch input

Push button input

CA

Active = GND

RS485 A line

8 CB RS485 B line

CONNECTOR 2 – connection of external reader

Contact Description

1 9-14V DC

2

3

4

5

GND

Data 0

Data 1

Buzzer output

6

7

8

LED output

XA – for protocol reader

XB – for protocol reader

Specification

Power supply

Ground

Wiegand protocol

Wiegand protocol

Active = GND

Active = GND

RS485 XA line

RS485 XB line

5/2014

www.jantar.si

REGIS T – Standalone, access or time and attendance controller

Inputs, outputs and environment

Inputs:

Inputs are realized with opto-isolators. The input is active, when pulled to ground with an open collector transistor or mechanical switch, which is connecting the input pin of the controller to the

Ground.

Outputs:

Output has a pre-installed protection diode for an inductive load. It is also protected from current overload. The best way is to use a

0.25A el. strike or a 0.5A el. magnet, which has to be connected to the same positive pole (+) as the controller. Connect the negative pole (-) to the door strike output (wire 3). When the output is active it is pulled to ground. This can be changed with function 5 – negate output (for el. magnet).

Environment:

Do not install the controller on/in a place, where it can come in contact with water. You must assure good cable joints, protected against moisture, otherwise corrosion may damage the controller.

Damage in such cases is not covered by the warranty.

Regis T-1-9-NET reading range:

The controller has a program algorithm that, at power start, sets parameters based on the installation environment, so as to ensure an optimal reading range. DO NOT install the controller directly on metal surfaces and/or cover it with a metal cover; it may stop working/reading. If you plan to test the controller and move it onto different surfaces, then you have to reset it (power off/on) on each surface.

ACCESS OR TIME AND ATTENDANCE

CONTROLLER

Access controller

As an access controller, it is intended for controlling entries, exits and passes of users in the system and controlling sliding doors, ramp, el. strike, turning alarm on/off… It needs to be set with V7 or CODEKS software.

Time and attendance controller

As a time and attendance controller, it is intended to register the employee’s arrivals and exits from work, lunch break, private and business exits, sick leave... It needs to be set with V7 or CODEKS software. In software you need to choose option “Time and attendance” for controller and reader. Set the software according to your requirements (time tables, users...) and send the tables.

The keypad will serve for choosing different time intervals (private, business…).

The controller switches to access or time and attendance controller when tables are sent by the software or when it is set to mode 4 with function 9. Change the controller’s address from 255 to any number between 1 and 254. If you have more controllers on the communication line, don’t duplicate addresses. Add them one by one on the communication line, because every controller has address

255 by default.

Communication

Ethernet:

Connect the controller to the computer through your LAN via

Ethernet connector. Use at least UTP CAT 5e cable. Adjust network settings of the controller using the Codeks Device Manager software so that it will function properly in your network. Please consult Codeks Device Manager manual.

S - Spider mode

In the Spider mode the controller can be used as a communication converter, from which you can continue RS485 communication line to the other controllers. When the controller is reset to the factory settings (brainwash), the controller address is set to 254.

RS485:

Connect the controller to the computer, with one of the power supplies, with communication converter, from the Spider family:

Spider W5-USB, Spider W5-NET, Spider W40+NET.

The RS485 communication bus is used between the controllers and

Jantar software. Up to 128 controllers can be lined up into one communication line. The maximum length of the communication line is 1000 cable meters. It is recommended that you use an FTP or S-FTP cable. Only a serial connection of controllers in a single communication line is allowed. Star (parallel) connection is not

allowed.

All shields of S-FTP cables must be wired together and at one

point connected to the earth. Individual connections to the earth are not allowed. Do not connect the shield of the cable to the ground of the controller.

In the event of problems in communication, a termination resistor needs to be added. We recommend using 120 Ohm resistors on each side of the cable. Converters are, on the

RS485 side, protected with slow-blow fuses and transient voltage suppressors.

Reset to the factory settings (brainwash):

When the controller is reset to the factory settings (brainwash), the controller address is set to 254.

ORDERING CODES

REGIS [box]-[card]-[software]

Box: T

Card: 1 – reading frequency 125kHz (cards)

3 – reading frequency 13.56MHz (cards)

Software: 9 – BLOCKER, CODEKS (support for V7 min.7.995.6.1027)

Communication: NET – Ethernet connection

Communication mode: S – Spider mode

Code

REGIS T-1-9-

NET

Description

Standalone or access controller in T box,

Frequency 125kHz, for BLOCKER, CODEKS or programs from V7 version, Integrated

Ethernet

REGIS T-1-9-

NET-S

REGIS T-3-9-

NET

REGIS T-3-9-

NET-S

Standalone or access controller in T box,

Frequency 125kHz, for BLOCKER, CODEKS or programs from V7 version, Integrated

Ethernet, Spider mode

Standalone or access controller in T box,

Frequency 13.56MHz, for BLOCKER,

CODEKS or programs from V7 version,

Integrated Ethernet

Standalone or access controller in T box,

Frequency 13.56MHz, for BLOCKER,

CODEKS or programs from V7 version,

Integrated Ethernet, Spider mode

OTHER

Warranty only applies when the controller Regis is used with power supply or/and communication converter from the Spider family.

Please read through our warranty and disclaimer statements.

Connection scheme and additional support for the use of this product can be found on: http://www.jantar.si/forum/en

CONTACT:

Jantar d.o.o.

Kranjska cesta 24

4202 Naklo

SLOVENIA web: mail: www.jantar.si

[email protected]

Black line

5/2014