AIDALARM A600P Pool alarm control panel

This is designed for use with latching call points such as the WRP-B-11 pool alarm call point.

Operation .

The AIDALARM is sited at a manned point for people to take action and it will give audible and visual indication. The call is silenced using the button on the AIDALARM. The call is reset by resetting the pool alarm callpoint and pressing the AIDALARM button if it has not already been pressed.

An optional S1703PY Light / Sounder with pushbutton can be fitted remotely for repeat silence and indication.

When a pool alarm call point is pressed, a warning is given at both the AIDALARM and the remote sounder beacon(s). Pressing the AIDALARM silence button, or the remote S1703PY silence button will result in the AIDALARM and silencing but leave the lights on to indicate that the system has been silenced. The sounder will sound briefly every minute to indicate that the pool alarm call point has not been reset. As re-assurance in the vicinity of the point of call, the remote lights will continue and the sounders will bleep approx. every minute to warn that the alarm has not been reset.

When the pool alarm is reset, the sounder will silence and the lights will clear.

STR

+Ve

SDR

+Ve

SDR

-Ve

STR

-Ve

Com

Reset

SDR

-ve

LED

-ve

Fn

+ ve

NO

Com

NC ve

+

ve

Call

Volt free auxiliary relay contacts change on alarm and mains fail

Bk Pp Rd

Battery

Connections

Set

[

Auxillary 12vdc output when powered by mains, max 150mA.

12vdc input if powering from a 12vdc power supply.

[

Use

Set Button

16vac from

Mains transformer

PB1

PB2

Call LED

-ve

+ve

Power LED

-ve

+ve

021-485SE aidalarm

8581750/HB

IP Sealed

Sounder Beacon

A600P Controller

Located in responders area

N E L

WRP-B-11

Pool Alarm

Call Point

S1703PY repeat silence and indication (optional)

P1 P2 BZ

+ L1

POOL

ALARM

COM N/O R11

ZD1

PB1

BZ1

B W Y B W Y

LED6

L8 L7 L6 L5

R8

NO

COM

LED5

NC

NO

COM

NC

Press to SILENCE

Programming

All settings made in programming mode will be maintained in memory even if power and batteries are removed. The following features of the system can be programmed.

A. Battery Fault Monitor

Battery fault monitoring can either be enabled (Default) or disabled if batteries are not being fitted.

The default setting is probably adequate for most applications but if it needs to be changed proceed as follows: Move the jumper on the PCB to the Set position. The LED’s will flash indicating the current setting

(BFM on Set 1 in the table opposite.) Toggle the BFM on and off by pressing the small Set Button on the reverse of the PCB. When finished either continue to set the tome as in (B) below, or move the Set mode jumper back to the Use mode.

B. Control panel alarm tone aidalarm

Control Panel Button

Set

1

LED

Display

Battery

Monitor

ON

Whilst in Set mode (jumper on the PCB in the Set position), press the control panel button in the centre of the LED diamond to move into tone setting mode, the LED will indicate steady. Repeatedly press the control panel button to scroll through the four different tones. Pause for 2 seconds after each press and the selected tone will play for 2 seconds. The last tone played is the tone that will be stored in memory.

When finished, move the Set mode jumper back to the Use mode.

2 OFF

Hoyles Electronic Developments Ltd

T. 01744 886600 F. 01744 886607 E. [email protected] W. www.hoyles.com

60138 Feb 2012