LEDJ LEDJ193 Stage Par CZ200 3200K Manual
Add to My manuals12 Pages
The Ledj LEDJ193 Stage Par CZ200 3200K is a high-output 200W white COB (chip-on-board) LED par designed for stage productions, concerts, or theatre applications. Its adjustable beam angle (13° to 50°) and motorized zoom allow for flexible beam shaping. The fixture offers 4 different dimmer curve options and various control modes, including DMX and manual. It features a 5-pin DMX and powerCON input/output, a gel frame holder, and a user-friendly menu with an LED display. The LEDJ193 is a versatile and professional lighting solution for a wide range of entertainment and event applications, providing high-quality warm white illumination with precise control.
advertisement
Stage Par CZ200 3200K
User Manual
Order code: LEDJ193
Safety advice
WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL
CAREFULLY BEFORE YOUR INITIAL START-UP!
• Before your initial start-up, please make sure that there is no damage caused during transportation.
• Should there be any damage, consult your dealer and do not use the equipment.
• To maintain the equipment in good working condition and to ensure safe operation, it is necessary for the user to follow the safety instructions and warning notes written in this manual.
• Please note that damages caused by user modifications to this equipment are not subject to warranty.
CAUTION!
KEEP THIS EQUIPMENT
AWAY FROM RAIN,
MOISTURE AND LIQUIDS
CAUTION!
TAKE CARE USING
THIS EQUIPMENT!
HIGH VOLTAGE-RISK
OF ELECTRIC SHOCK!!
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorised modification to the equipment.
• Never let the power cable come into contact with other cables. Handle the power cable and all mains voltage connections with particular caution!
• Never remove warning or informative labels from the unit.
• Do not open the equipment and do not modify the unit.
• If the equipment has been exposed to drastic temperature fluctuation (e.g. after transportation), do not connect power or switch it on immediately.
The arising condensation might damage the equipment.
Leave the equipment switched off until it has reached room temperature.
• Do not connect this equipment to a dimmer pack.
• Do not switch the equipment on and off in short intervals, as this will reduce the system’s life.
• Only use the equipment indoors.
• If your product fails to function correctly, stop use immediately. Pack the unit securely (preferably in the original packing material), and return it to your Pro Light dealer for service.
• Do not expose to flammable sources, liquids or gases.
• Only use fuses of same type and rating.
• Always disconnect the power from the mains when equipment is not in use or before cleaning! Only handle the power-cable by the plug. Never pull out the plug by pulling the power-cable.
• Make sure that the available mains supply voltage is between 100~240V AC, 50/60Hz.
• Make sure that the power cable is never crimped or damaged. Check the equipment and the power cable periodically.
• Repairs, servicing and power connection must only be carried out by a qualified technician. THIS UNIT CONTAINS
NO USER SERVICEABLE PARTS.
• This lighting fixture is for professional use only - it is not designed for or suitable for household use. The product must be installed by a qualified technician in accordance with local territory regulations. The safety of the installation is the responsibility of the installer. The fixture presents risks of severe injury or death due to fire hazards, electric shock and falls.
• If the equipment is dropped or damaged, disconnect the mains power supply immediately and have a qualified engineer inspect the equipment before operating again.
• Warning! Risk Group 2 LED product according to
EN 62471. Do not view the light output with optical instruments or any device that may concentrate the beam.
OPERATING DETERMINATIONS
• WARRANTY: One year from date of purchase.
If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and the warranty becomes void. Incorrect operation may lead to danger e.g: short-circuit, burns and electric shocks etc.
Do not endanger your own safety and the safety of others!
Incorrect installation or use can cause serious damage to people and/or property.
www.prolight.co.uk
Stage Par CZ200 3200K User Manual
2
Product overview & technical specifications
Stage Par CZ200 3200K
The CZ200 3200K Stage Par is powered by a high output 200W white COB
(chip-on-board) LED, ideal for stage productions, concerts or theatre applications.
The motorised zoom allows the beam angle to be adjusted via DMX or manual modes between 13° and 50° and on-board controls offer 4 different dimmer curve options, whilst the 5-pin DMX and powerCON input/output allow for easy connections, adding to the host of professional features on these fixtures.
A gel frame holder is supplied enabling diffusion filters to be fitted.
• 1 x 200W warm white LED (3200K)
• Adjustable beam angle: 13°- 50°
• 13° - 39,362 Lux @ 2m,
50° - 5,877 Lux @ 2m
• CRI: 95
• 11.8kHz refresh rate
• Motorised zoom
• DMX channels: 2/3 or 5 selectable
• Manual mode
• 0 - 100% dimming with variable strobe
• Supplied with hanging bracket
• 4 push button menu with LED display
• PowerCON input/output
• 5-Pin XLR input/output
• Fan cooled
• Supplied with filter frame
13° - Lux
50° - Lux
0m
157448
23508
1m
39362
5877
2m
Specifications
Power consumption
Power supply
Fuse
Dimensions
Weight
Order codes
Stage Par CZ200 3200K
205W
100~240V, 50/60Hz
F4A 250V
370 x 275 x 390mm
4.3kg
LEDJ193
10
17494
2612
3m
05
9840
1469
13° 50°
4m
6297
940
5m
09
01 - LED display
02 - Function buttons
03 - 5-Pin XLR input
04 - 5-Pin XLR output
05 - PowerCON input
06 - PowerCON output
07 - Fuse F4A 250V
08 - Earth point
09 - Safety eye
10 - Hanging bracket
11 - Hanging bracket
adjustment knob www.prolight.co.uk
In the box: 1 x fixture,
1 x filter frame,
1 x power cable
& 1 x user manual
03
04
02 01
08 06
07
11
Stage Par CZ200 3200K User Manual
3
275mm
250mm
Product overview & technical specifications
390mm
365mm
30mm
130mm
MENU
A d d r
C H A N d N S t
C u r V
A 0 0 1
A 5 1 2
2 C H
3 C H
5 C H b L N d
L A S t
L I N E
S q U A
I S q U
S C U r
DMX address setting
Channel modes
No DMX signal
Dimming curves www.prolight.co.uk
Stage Par CZ200 3200K User Manual
4
MENU
P r O F
L E D
D I S P
M A N U
T E S T
T E M P
F H R S
R E S T
V E R
L E D
H A L O
O F F
O N d I S P d S I p
Dimmer speed setting
LED backlight
Display invert
W
S
Z
- - -
- - -
- - -
W 0 0 0
W 2 5 5
S 0 0 0
S 2 5 5
Z 0 0 0
Z 2 5 5
Auto test
Manual mode
A U T O
- - - -
- - H
Y E S
N O
V - - -
Fixture temperature
Fixture hours
Reset factory settings
Software version www.prolight.co.uk
Stage Par CZ200 3200K User Manual
5
Operating instructions
DMX mode:
Operating in a DMX control mode environment gives the user the greatest flexibility when it comes to customising or creating a show. In this mode you will be able to control each individual trait of the fixture and each fixture independently.
To access the DMX address mode, press the “MENU” button and use the “UP” and “DOWN” buttons to show ADDR on the LED display. Now press the “ENTER” button and use the “UP” and “DOWN” buttons to set the required DMX address. Press the “ENTER” button to confirm the setting.
To exit out of any of the above options, press the “MENU” button.
DMX channel mode:
To access the DMX channel mode, press the “MENU” button and use the “UP” and “DOWN” buttons to show CHAN on the LED display. Now press the “ENTER” button and use the “UP” and “DOWN” buttons to choose one of the 2/3 or 5 DMX channel modes. Press the “ENTER” button to confirm the setting. To exit out of any of the above options, press the “MENU” button.
2 channel mode: 5 channel mode:
Channel Value
CH1
Function
000-255 Master dimmer (0-100%)
CH2 000-255 Zoom (marrow-wide)
3 channel mode:
Channel Value
CH1
Function
000-255 Master dimmer (0-100%)
CH2 000-255 Zoom (narrow-wide)
000-031 No function
032-063 Open
064-095 Strobe (slow-fast)
096-127 Open
CH3
128-159 Pulse strobe (slow-fast)
160-191 Open
192-223 Random strobe (slow-fast)
224-255 Open
Channel Value
CH1
Function
000-255 Master dimmer (0-100%)
CH2
CH3
000-255 Zoom (narrow-wide)
000-255 Zoom speed (fast-slow)
000-031 No function
CH4
032-063 Open
064-095 Strobe (slow-fast)
096-127 Open
128-159 Pulse strobe (slow-fast)
160-191 Open
192-223 Random strobe (slow-fast)
224-255 Open
CH5
000-050 Default (set on unit)
051-100 Linear
101-150 Square
151-200 Inverse Square
201-240 S-Curve
241-250 No function
251-255 Reset (hold 5s) www.prolight.co.uk
Stage Par CZ200 3200K User Manual
6
Operating instructions
No DMX signal:
To change how the unit responds when the DMX signal is lost, press the “MENU” button and use the
“UP” and “DOWN” buttons to show dNSt on the LED display. Now press the “ENTER” button and use the “UP” and “DOWN” buttons to choose between LAst (Hold the last DMX command) or bLNd (Blackout). Press the “ENTER” button to confirm the setting.
To exit out of any of the above options, press the “MENU” button.
Dimming curves:
To access the dimming curve setting, press the “MENU” button to show CUrV on the LED display.
Now press the “ENTER” button and use the “UP” and “DOWN” buttons to choose between
LINE (Linear), SQUA (Square), ISQU (Inverse square) or SCUR (S-Curve).
Press the “ENTER” button to confirm the setting.
To exit out of any of the above options, press the “MENU” button.
Dimming speed:
To access the dimmer speed setting, press the “MENU” button and use the “UP” and “DOWN” buttons to show PROF on the LED display. Now press the “ENTER” button and use the “UP” and “DOWN” buttons to choose between LED (LED) or HALO (Halogen).
Press the “ENTER” button to confirm the setting.
To exit out of any of the above options, press the “MENU” button.
LED backlight:
To access the LED backlight setting, press the “MENU” button and use the “UP” and “DOWN” buttons to show LED on the LED display. Now press the “ENTER” button and use the “UP” and “DOWN” buttons to choose between ON or OfF . Press the “ENTER” button to confirm the setting. To exit out of any of the above options, press the “MENU” button.
Display invert setting:
To access the display invert setting, press the “MENU” button and use the “UP” and “DOWN” buttons to show DISP on the LED display. Now press the “ENTER” button and use the “UP” and “DOWN” buttons to choose between dISP or dSIP . Press the “ENTER” button to confirm the setting. To exit out of any of the above options, press the “MENU” button.
Manual mode:
To access manual mode, press the “MENU” button to show MANU on the LED display.
Now press the “ENTER” button and use the “UP” and “DOWN” buttons to choose between
W (White dimmer), S (Strobe) and Z (Zoom).
Press the “ENTER” button and use the “UP” and “DOWN” buttons to choose between 000 ~ 255 .
Press the “ENTER” button to confirm the setting.
To exit out of any of the above options, press the “MENU” button.
www.prolight.co.uk
Stage Par CZ200 3200K User Manual
7
Operating instructions
Test mode:
To access the test mode, press the “MENU” button and use the “UP” and “DOWN” buttons to show
TEST on the LED display. Now press the “ENTER” button.
The unit will now display AUTO and run the fixtures test mode.
To exit out of any of the above options, press the “MENU” button.
Fixture temperature:
To access the fixtures temperature, press the “MENU” button and use the “UP” and “DOWN” buttons to show TEMP on the LED display. Now press the “ENTER” button.
The unit will now display the fixtures temperature.
To exit out of any of the above options, press the “MENU” button.
Fixture hours:
To access the fixtures usage time, press the “MENU” button and use the “UP” and “DOWN” buttons to show FHRS on the LED display. Now press the “ENTER” button.
The unit will now display the fixtures usage time (hours).
To exit out of any of the above options, press the “MENU” button.
Reset factory settings:
To reset factory settings, press the “MENU” button and use the “UP” and “DOWN” buttons to show
REST on the LED display. Now press the “ENTER” button and use the “UP” and “DOWN” buttons to choose YES . Press the “ENTER” button to confirm the setting. The fixture will reset to factory default settings. To exit out of any of the above options, press the “MENU” button.
Software version:
To access the fixtures software version, press the “MENU” button and use the “UP” and “DOWN” buttons to show VER on the LED display. Now press the “ENTER” button.
The unit will now display the fixtures software version.
To exit out of any of the above options, press the “MENU” button.
www.prolight.co.uk
Stage Par CZ200 3200K User Manual
8
DMX setup
Setting the DMX address:
The DMX mode enables the use of a universal DMX controller. Each fixture requires a “start address” from 1- 512. A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address. For example, a fixture that occupies or uses 7 channels of DMX and was addressed to start on DMX channel 100, would read data from channels: 100, 101, 102, 103, 104,
105 and 106. Choose a start address so that the channels used do not overlap. E.g. the next unit in the chain starts at 107.
DMX 512:
DMX (Digital Multiplex) is a universal protocol used as a form of communication between intelligent fixtures and controllers. A DMX controller sends DMX data instructions form the controller to the fixture.
DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT”
XLR terminals located on all DMX fixtures (most controllers only have a data “out” terminal).
DMX linking:
DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller, as long as all fixtures and the controller are DMX compliant.
To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest cable path possible. The order in which fixtures are connected in a DMX line does not influence the
DMX addressing. For example; a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a
DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter where it is located in the DMX chain.
DATA cable (DMX cable) requirements (for DMX operation):
This fixture can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit.
Your unit requires either a standard 3-pin or 5-pin XLR connector for data input/output, see images below.
Further DMX cables can be purchased from all good sound and lighting suppliers or Prolight Concepts dealers.
Please quote: 3-Pin: CABL10 – 2m CABL11 – 5m CABL12 – 10m
5-Pin: CABL185 – 2m CABL187 – 5m CABL188 – 10m
Also remember that DMX cable must be daisy chained and cannot be split.
www.prolight.co.uk
Stage Par CZ200 3200K User Manual
9
DMX setup
Notice:
Be sure to follow the diagrams below when making your own cables.
Do not connect the cables shield conductor to the ground lug or allow the shield conductor to come in contact with the XLRs outer casing. Grounding the shield could cause a short circuit and erratic behaviour.
Pin Configuration
3-Pin 5-Pin
Pin 1 - Ground
–
–
Pin 2 - Negative
Pin 3 - Positive
Pin 4 - N/C
Pin 5 - N/C
3-Pin XLR female
DMX 512
3-Pin XLR output
1
2
3
GROUND
DMX +
DMX –
DMX 512
3-Pin XLR input
3
1
2
3-Pin XLR male
DMX 512
5-Pin XLR output
DMX 512
5-Pin XLR input
1 2
5 4
3
DMX –
N/C
GROUND
DMX +
N/C
3
2
1
4 5
Line termination:
When longer runs of cable are used, you may need to use a terminator on the last unit to avoid erratic behaviour.
Using a cable terminator will decrease the possibilities of erratic behaviour.
(3-pin - Order ref: CABL90,
5-pin - Order ref: CABL89)
3-Pin
1
3
2
1 ground
3 hot
5-Pin XLR male
2 cold 2 cold
3 hot
1 ground
5-Pin XLR female
1 ground
2 cold
3 hot
5 N/C
4 N/C
5 N/C
4 N/C
3 hot
1 ground
2 cold
Termination reduces signal transmission problems and interference. It is always advisable to connect a DMX terminal, (resistance 120
Ohm 1/4W) between pin 2
(DMX-) and pin 3 (DMX+) of the last fixture.
5-Pin
1
2
3
4
5
5-pin XLR DMX connectors:
Some manufactures use 5-pin XLR connectors for data transmission in place of 3-pin. 5-pin XLR fixtures may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin XLR connectors in to a
3-pin line a cable adaptor must be used. The diagram below details the correct cable conversion.
5-pin XLR (female)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
3-pin XLR (male)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
3-pin XLR (female)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
5-pin XLR (male)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C www.prolight.co.uk
Stage Par CZ200 3200K User Manual
10
Multiple fixture power linking
Power linking:
This fixture provides power linking via the power output on the rear allowing multiple units to be connected together. The maximum number of fixtures that can be connected is 8 fixtures @ 240V or 4 fixtures @ 120V (including the first fixture). After the maximum number of fixtures are connected a new power run will need to be started.
Please note: Caution should be used when power linking other fixtures to the Stage Par CZ 200 3200K as the power consumption of other fixtures will vary. Fixtures fitted with lamps often require 2/3 times more current on startup, these may require their own power source.
www.prolight.co.uk
Stage Par CZ200 3200K User Manual
11
WEEE notice
Correct Disposal of this Product
(Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries with separate collection systems)
This marking shown on the product or its literature, indicates that it should not be disposed of with other household wastes at the end of its working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how they can take this item for environmentally safe recycling.
Business users should contact their supplier and check the terms and conditions of the purchase contract. This product should not be mixed with other commercial wastes for disposal.
www.prolight.co.uk
Stage Par CZ200 3200K User Manual
12
advertisement
Key Features
- High-output 200W warm white COB (3200K) LED
- Adjustable beam angle: 13° to 50°
- Motorized zoom for precise beam shaping
- 4 different dimmer curve options
- DMX and manual control modes
- 5-pin DMX and powerCON input/output
- Gel frame holder for diffusion filters
- User-friendly menu with LED display
- Compact and lightweight design
Related manuals
Frequently Answers and Questions
What is the power consumption of the Ledj LEDJ193?
What are the dimensions of the Ledj LEDJ193?
What is the beam angle range of the Ledj LEDJ193?
Can I use the Ledj LEDJ193 in a DMX control mode?
What is the CRI of the Ledj LEDJ193?
advertisement