LEDJ LEDJ193 Stage Par CZ200 3200K Manual

Add to My manuals
12 Pages

advertisement

LEDJ LEDJ193 Stage Par CZ200 3200K Manual | Manualzz

Stage Par CZ200 3200K

User Manual

Order code: LEDJ193

Safety advice

WARNING

FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL

CAREFULLY BEFORE YOUR INITIAL START-UP!

• Before your initial start-up, please make sure that there is no damage caused during transportation.

• Should there be any damage, consult your dealer and do not use the equipment.

• To maintain the equipment in good working condition and to ensure safe operation, it is necessary for the user to follow the safety instructions and warning notes written in this manual.

• Please note that damages caused by user modifications to this equipment are not subject to warranty.

CAUTION!

KEEP THIS EQUIPMENT

AWAY FROM RAIN,

MOISTURE AND LIQUIDS

CAUTION!

TAKE CARE USING

THIS EQUIPMENT!

HIGH VOLTAGE-RISK

OF ELECTRIC SHOCK!!

IMPORTANT:

The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorised modification to the equipment.

• Never let the power cable come into contact with other cables. Handle the power cable and all mains voltage connections with particular caution!

• Never remove warning or informative labels from the unit.

• Do not open the equipment and do not modify the unit.

• If the equipment has been exposed to drastic temperature fluctuation (e.g. after transportation), do not connect power or switch it on immediately.

The arising condensation might damage the equipment.

Leave the equipment switched off until it has reached room temperature.

• Do not connect this equipment to a dimmer pack.

• Do not switch the equipment on and off in short intervals, as this will reduce the system’s life.

• Only use the equipment indoors.

• If your product fails to function correctly, stop use immediately. Pack the unit securely (preferably in the original packing material), and return it to your Pro Light dealer for service.

• Do not expose to flammable sources, liquids or gases.

• Only use fuses of same type and rating.

• Always disconnect the power from the mains when equipment is not in use or before cleaning! Only handle the power-cable by the plug. Never pull out the plug by pulling the power-cable.

• Make sure that the available mains supply voltage is between 100~240V AC, 50/60Hz.

• Make sure that the power cable is never crimped or damaged. Check the equipment and the power cable periodically.

• Repairs, servicing and power connection must only be carried out by a qualified technician. THIS UNIT CONTAINS

NO USER SERVICEABLE PARTS.

• This lighting fixture is for professional use only - it is not designed for or suitable for household use. The product must be installed by a qualified technician in accordance with local territory regulations. The safety of the installation is the responsibility of the installer. The fixture presents risks of severe injury or death due to fire hazards, electric shock and falls.

• If the equipment is dropped or damaged, disconnect the mains power supply immediately and have a qualified engineer inspect the equipment before operating again.

• Warning! Risk Group 2 LED product according to

EN 62471. Do not view the light output with optical instruments or any device that may concentrate the beam.

OPERATING DETERMINATIONS

• WARRANTY: One year from date of purchase.

If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and the warranty becomes void. Incorrect operation may lead to danger e.g: short-circuit, burns and electric shocks etc.

Do not endanger your own safety and the safety of others!

Incorrect installation or use can cause serious damage to people and/or property.

www.prolight.co.uk

Stage Par CZ200 3200K User Manual

2

Product overview & technical specifications

Stage Par CZ200 3200K

The CZ200 3200K Stage Par is powered by a high output 200W white COB

(chip-on-board) LED, ideal for stage productions, concerts or theatre applications.

The motorised zoom allows the beam angle to be adjusted via DMX or manual modes between 13° and 50° and on-board controls offer 4 different dimmer curve options, whilst the 5-pin DMX and powerCON input/output allow for easy connections, adding to the host of professional features on these fixtures.

A gel frame holder is supplied enabling diffusion filters to be fitted.

• 1 x 200W warm white LED (3200K)

• Adjustable beam angle: 13°- 50°

• 13° - 39,362 Lux @ 2m,

50° - 5,877 Lux @ 2m

• CRI: 95

• 11.8kHz refresh rate

• Motorised zoom

• DMX channels: 2/3 or 5 selectable

• Manual mode

• 0 - 100% dimming with variable strobe

• Supplied with hanging bracket

• 4 push button menu with LED display

• PowerCON input/output

• 5-Pin XLR input/output

• Fan cooled

• Supplied with filter frame

13° - Lux

50° - Lux

0m

157448

23508

1m

39362

5877

2m

Specifications

Power consumption

Power supply

Fuse

Dimensions

Weight

Order codes

Stage Par CZ200 3200K

205W

100~240V, 50/60Hz

F4A 250V

370 x 275 x 390mm

4.3kg

LEDJ193

10

17494

2612

3m

05

9840

1469

13° 50°

4m

6297

940

5m

09

01 - LED display

02 - Function buttons

03 - 5-Pin XLR input

04 - 5-Pin XLR output

05 - PowerCON input

06 - PowerCON output

07 - Fuse F4A 250V

08 - Earth point

09 - Safety eye

10 - Hanging bracket

11 - Hanging bracket

adjustment knob www.prolight.co.uk

In the box: 1 x fixture,

1 x filter frame,

1 x power cable

& 1 x user manual

03

04

02 01

08 06

07

11

Stage Par CZ200 3200K User Manual

3

275mm

250mm

Product overview & technical specifications

390mm

365mm

30mm

130mm

MENU

A d d r

C H A N d N S t

C u r V

A 0 0 1

A 5 1 2

2 C H

3 C H

5 C H b L N d

L A S t

L I N E

S q U A

I S q U

S C U r

DMX address setting

Channel modes

No DMX signal

Dimming curves www.prolight.co.uk

Stage Par CZ200 3200K User Manual

4

MENU

P r O F

L E D

D I S P

M A N U

T E S T

T E M P

F H R S

R E S T

V E R

L E D

H A L O

O F F

O N d I S P d S I p

Dimmer speed setting

LED backlight

Display invert

W

S

Z

- - -

- - -

- - -

W 0 0 0

W 2 5 5

S 0 0 0

S 2 5 5

Z 0 0 0

Z 2 5 5

Auto test

Manual mode

A U T O

- - - -

- - H

Y E S

N O

V - - -

Fixture temperature

Fixture hours

Reset factory settings

Software version www.prolight.co.uk

Stage Par CZ200 3200K User Manual

5

Operating instructions

DMX mode:

Operating in a DMX control mode environment gives the user the greatest flexibility when it comes to customising or creating a show. In this mode you will be able to control each individual trait of the fixture and each fixture independently.

To access the DMX address mode, press the “MENU” button and use the “UP” and “DOWN” buttons to show ADDR on the LED display. Now press the “ENTER” button and use the “UP” and “DOWN” buttons to set the required DMX address. Press the “ENTER” button to confirm the setting.

To exit out of any of the above options, press the “MENU” button.

DMX channel mode:

To access the DMX channel mode, press the “MENU” button and use the “UP” and “DOWN” buttons to show CHAN on the LED display. Now press the “ENTER” button and use the “UP” and “DOWN” buttons to choose one of the 2/3 or 5 DMX channel modes. Press the “ENTER” button to confirm the setting. To exit out of any of the above options, press the “MENU” button.

2 channel mode: 5 channel mode:

Channel Value

CH1

Function

000-255 Master dimmer (0-100%)

CH2 000-255 Zoom (marrow-wide)

3 channel mode:

Channel Value

CH1

Function

000-255 Master dimmer (0-100%)

CH2 000-255 Zoom (narrow-wide)

000-031 No function

032-063 Open

064-095 Strobe (slow-fast)

096-127 Open

CH3

128-159 Pulse strobe (slow-fast)

160-191 Open

192-223 Random strobe (slow-fast)

224-255 Open

Channel Value

CH1

Function

000-255 Master dimmer (0-100%)

CH2

CH3

000-255 Zoom (narrow-wide)

000-255 Zoom speed (fast-slow)

000-031 No function

CH4

032-063 Open

064-095 Strobe (slow-fast)

096-127 Open

128-159 Pulse strobe (slow-fast)

160-191 Open

192-223 Random strobe (slow-fast)

224-255 Open

CH5

000-050 Default (set on unit)

051-100 Linear

101-150 Square

151-200 Inverse Square

201-240 S-Curve

241-250 No function

251-255 Reset (hold 5s) www.prolight.co.uk

Stage Par CZ200 3200K User Manual

6

Operating instructions

No DMX signal:

To change how the unit responds when the DMX signal is lost, press the “MENU” button and use the

“UP” and “DOWN” buttons to show dNSt on the LED display. Now press the “ENTER” button and use the “UP” and “DOWN” buttons to choose between LAst (Hold the last DMX command) or bLNd (Blackout). Press the “ENTER” button to confirm the setting.

To exit out of any of the above options, press the “MENU” button.

Dimming curves:

To access the dimming curve setting, press the “MENU” button to show CUrV on the LED display.

Now press the “ENTER” button and use the “UP” and “DOWN” buttons to choose between

LINE (Linear), SQUA (Square), ISQU (Inverse square) or SCUR (S-Curve).

Press the “ENTER” button to confirm the setting.

To exit out of any of the above options, press the “MENU” button.

Dimming speed:

To access the dimmer speed setting, press the “MENU” button and use the “UP” and “DOWN” buttons to show PROF on the LED display. Now press the “ENTER” button and use the “UP” and “DOWN” buttons to choose between LED (LED) or HALO (Halogen).

Press the “ENTER” button to confirm the setting.

To exit out of any of the above options, press the “MENU” button.

LED backlight:

To access the LED backlight setting, press the “MENU” button and use the “UP” and “DOWN” buttons to show LED on the LED display. Now press the “ENTER” button and use the “UP” and “DOWN” buttons to choose between ON or OfF . Press the “ENTER” button to confirm the setting. To exit out of any of the above options, press the “MENU” button.

Display invert setting:

To access the display invert setting, press the “MENU” button and use the “UP” and “DOWN” buttons to show DISP on the LED display. Now press the “ENTER” button and use the “UP” and “DOWN” buttons to choose between dISP or dSIP . Press the “ENTER” button to confirm the setting. To exit out of any of the above options, press the “MENU” button.

Manual mode:

To access manual mode, press the “MENU” button to show MANU on the LED display.

Now press the “ENTER” button and use the “UP” and “DOWN” buttons to choose between

W (White dimmer), S (Strobe) and Z (Zoom).

Press the “ENTER” button and use the “UP” and “DOWN” buttons to choose between 000 ~ 255 .

Press the “ENTER” button to confirm the setting.

To exit out of any of the above options, press the “MENU” button.

www.prolight.co.uk

Stage Par CZ200 3200K User Manual

7

Operating instructions

Test mode:

To access the test mode, press the “MENU” button and use the “UP” and “DOWN” buttons to show

TEST on the LED display. Now press the “ENTER” button.

The unit will now display AUTO and run the fixtures test mode.

To exit out of any of the above options, press the “MENU” button.

Fixture temperature:

To access the fixtures temperature, press the “MENU” button and use the “UP” and “DOWN” buttons to show TEMP on the LED display. Now press the “ENTER” button.

The unit will now display the fixtures temperature.

To exit out of any of the above options, press the “MENU” button.

Fixture hours:

To access the fixtures usage time, press the “MENU” button and use the “UP” and “DOWN” buttons to show FHRS on the LED display. Now press the “ENTER” button.

The unit will now display the fixtures usage time (hours).

To exit out of any of the above options, press the “MENU” button.

Reset factory settings:

To reset factory settings, press the “MENU” button and use the “UP” and “DOWN” buttons to show

REST on the LED display. Now press the “ENTER” button and use the “UP” and “DOWN” buttons to choose YES . Press the “ENTER” button to confirm the setting. The fixture will reset to factory default settings. To exit out of any of the above options, press the “MENU” button.

Software version:

To access the fixtures software version, press the “MENU” button and use the “UP” and “DOWN” buttons to show VER on the LED display. Now press the “ENTER” button.

The unit will now display the fixtures software version.

To exit out of any of the above options, press the “MENU” button.

www.prolight.co.uk

Stage Par CZ200 3200K User Manual

8

DMX setup

Setting the DMX address:

The DMX mode enables the use of a universal DMX controller. Each fixture requires a “start address” from 1- 512. A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address. For example, a fixture that occupies or uses 7 channels of DMX and was addressed to start on DMX channel 100, would read data from channels: 100, 101, 102, 103, 104,

105 and 106. Choose a start address so that the channels used do not overlap. E.g. the next unit in the chain starts at 107.

DMX 512:

DMX (Digital Multiplex) is a universal protocol used as a form of communication between intelligent fixtures and controllers. A DMX controller sends DMX data instructions form the controller to the fixture.

DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT”

XLR terminals located on all DMX fixtures (most controllers only have a data “out” terminal).

DMX linking:

DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller, as long as all fixtures and the controller are DMX compliant.

To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest cable path possible. The order in which fixtures are connected in a DMX line does not influence the

DMX addressing. For example; a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a

DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter where it is located in the DMX chain.

DATA cable (DMX cable) requirements (for DMX operation):

This fixture can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit.

Your unit requires either a standard 3-pin or 5-pin XLR connector for data input/output, see images below.

Further DMX cables can be purchased from all good sound and lighting suppliers or Prolight Concepts dealers.

Please quote: 3-Pin: CABL10 – 2m CABL11 – 5m CABL12 – 10m

5-Pin: CABL185 – 2m CABL187 – 5m CABL188 – 10m

Also remember that DMX cable must be daisy chained and cannot be split.

www.prolight.co.uk

Stage Par CZ200 3200K User Manual

9

DMX setup

Notice:

Be sure to follow the diagrams below when making your own cables.

Do not connect the cables shield conductor to the ground lug or allow the shield conductor to come in contact with the XLRs outer casing. Grounding the shield could cause a short circuit and erratic behaviour.

Pin Configuration

3-Pin 5-Pin

Pin 1 - Ground

Pin 2 - Negative

Pin 3 - Positive

Pin 4 - N/C

Pin 5 - N/C

3-Pin XLR female

DMX 512

3-Pin XLR output

1

2

3

GROUND

DMX +

DMX –

DMX 512

3-Pin XLR input

3

1

2

3-Pin XLR male

DMX 512

5-Pin XLR output

DMX 512

5-Pin XLR input

1 2

5 4

3

DMX –

N/C

GROUND

DMX +

N/C

3

2

1

4 5

Line termination:

When longer runs of cable are used, you may need to use a terminator on the last unit to avoid erratic behaviour.

Using a cable terminator will decrease the possibilities of erratic behaviour.

(3-pin - Order ref: CABL90,

5-pin - Order ref: CABL89)

3-Pin

1

3

2

1 ground

3 hot

5-Pin XLR male

2 cold 2 cold

3 hot

1 ground

5-Pin XLR female

1 ground

2 cold

3 hot

5 N/C

4 N/C

5 N/C

4 N/C

3 hot

1 ground

2 cold

Termination reduces signal transmission problems and interference. It is always advisable to connect a DMX terminal, (resistance 120

Ohm 1/4W) between pin 2

(DMX-) and pin 3 (DMX+) of the last fixture.

5-Pin

1

2

3

4

5

5-pin XLR DMX connectors:

Some manufactures use 5-pin XLR connectors for data transmission in place of 3-pin. 5-pin XLR fixtures may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin XLR connectors in to a

3-pin line a cable adaptor must be used. The diagram below details the correct cable conversion.

5-pin XLR (female)

Pin 1: GND (screen)

Pin 2: Signal (-)

Pin 3: Signal (+)

Pin 4: N/C

Pin 5: N/C

3-pin XLR (male)

Pin 1: GND (screen)

Pin 2: Signal (-)

Pin 3: Signal (+)

3-pin XLR (female)

Pin 1: GND (screen)

Pin 2: Signal (-)

Pin 3: Signal (+)

5-pin XLR (male)

Pin 1: GND (screen)

Pin 2: Signal (-)

Pin 3: Signal (+)

Pin 4: N/C

Pin 5: N/C www.prolight.co.uk

Stage Par CZ200 3200K User Manual

10

Multiple fixture power linking

Power linking:

This fixture provides power linking via the power output on the rear allowing multiple units to be connected together. The maximum number of fixtures that can be connected is 8 fixtures @ 240V or 4 fixtures @ 120V (including the first fixture). After the maximum number of fixtures are connected a new power run will need to be started.

Please note: Caution should be used when power linking other fixtures to the Stage Par CZ 200 3200K as the power consumption of other fixtures will vary. Fixtures fitted with lamps often require 2/3 times more current on startup, these may require their own power source.

www.prolight.co.uk

Stage Par CZ200 3200K User Manual

11

WEEE notice

Correct Disposal of this Product

(Waste Electrical & Electronic Equipment)

(Applicable in the European Union and other European countries with separate collection systems)

This marking shown on the product or its literature, indicates that it should not be disposed of with other household wastes at the end of its working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources.

Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how they can take this item for environmentally safe recycling.

Business users should contact their supplier and check the terms and conditions of the purchase contract. This product should not be mixed with other commercial wastes for disposal.

www.prolight.co.uk

Stage Par CZ200 3200K User Manual

12

advertisement

Key Features

  • High-output 200W warm white COB (3200K) LED
  • Adjustable beam angle: 13° to 50°
  • Motorized zoom for precise beam shaping
  • 4 different dimmer curve options
  • DMX and manual control modes
  • 5-pin DMX and powerCON input/output
  • Gel frame holder for diffusion filters
  • User-friendly menu with LED display
  • Compact and lightweight design

Related manuals

Frequently Answers and Questions

What is the power consumption of the Ledj LEDJ193?
The power consumption of the Ledj LEDJ193 is 205W.
What are the dimensions of the Ledj LEDJ193?
The dimensions of the Ledj LEDJ193 are 370 x 275 x 390mm (14.57 x 10.83 x 15.35 inches).
What is the beam angle range of the Ledj LEDJ193?
The beam angle range of the Ledj LEDJ193 is 13° to 50°.
Can I use the Ledj LEDJ193 in a DMX control mode?
Yes, the Ledj LEDJ193 can be controlled via DMX using 2, 3, or 5 DMX channels.
What is the CRI of the Ledj LEDJ193?
The CRI of the Ledj LEDJ193 is 95.

advertisement