Symmons S440815TRM Carrington 1-Handle 1.5 GPM Wall Mount Shower Trim Kit Installation & Operation Instructions

Add to My manuals
8 Pages

advertisement

Symmons S440815TRM Carrington 1-Handle 1.5 GPM Wall Mount Shower Trim Kit Installation & Operation Instructions | Manualzz

Carrington

®

Carrington Trim Series

Carrington Trim Series with TA-10 Flow Control Spindle &

T-12A Cap Assembly

Installation & Operation Instructions

Model Numbers

TRIM ONLY

S-4400-TRM

Shower Valve Trim

S-4401-TRM

Shower Trim

S-4402-TRM

Tub/Shower Trim

S-4404-TRM

Tub/Hand Shower Trim

S4408TRM

Shower/Hand Shower Trim

TRIM, TA-10, T-12A

S4400TRMTC

Shower Valve Trim

S4401TRMTC

Shower Trim

S4402TRMTC

Tub/Shower Trim

S4404TRMTC

Tub/Hand Shower Trim

S4408TRMTC

Shower/Hand Shower Trim

S-4400-TRM

S4400TRMTC

S-4401-TRM

S4401TRMTC

S-4402-TRM

S4402TRMTC

Compliance

• ASME A112.18.1/CSA B125.1

T-12A TA-10

Warranty

Limited Lifetime - to the original end purchaser in consumer/residential installations.

5 Years - for industrial/commercial installations.

Refer to www.symmons.com/warranty for complete warranty information.

Go to www.symmons.com/register to register your

Symmons product.

S-4404-TRM

S4404TRMTC

S4408TRM

S4408TRMTC

1. Recommended Tools

FIGURE 1

Adjustable Wrench

2. Dimensions

Allen Wrench (3mm) Drill Phillips Screwdriver Safety Glasses Thread Seal Tape

II

FIGURE 2

BB

EE

JJ

CC

FF

M

N

O

P

Q

R

S

A

B

C

D

E

F

G

H

I

J

K

L

Measurements

Ø 2-5/8", 67 mm

9-1/4", 235 mm

1/2" NPT

2-1/8", 54 mm

1/2", 13 mm

Male 1/2" IPS thread must be recessed 1/4" from finished wall

6", 152 mm right or left

77", 1956 mm

Ø 7-1/2", 191 mm

3-1/2", 89 MM

Ø 2-5/8", 67 mm

Trim with tub spout:

Ref. 32", 813 mm

Trim without tub spout:

Ref. 42", 1067 mm

12", 305 mm

3-1/8", 79 mm

2-3/4", 70 mm

(Rough in)

2" ± 1/2", 51 mm ± 13 mm

1/2" NPT

1/2", 13 mm

6-1/2", 165 mm

KK

LL

RR

PP

SS

Notes:

1) Valve body and piping not included and shown as reference only.

2) Plaster shield (p/n T-176) for dry wall, plaster or other type walls 1/2" or greater.

3) All dimensions measured from nominal rough-in (see P as reference).

4) Dimensions subject to change without notice.

2

3. Parts Breakdown (Model Numbers Ending in TRMTC)

LIMIT STOP

SCREW

2

Item

1

2

Replacement Parts

Description

Cap Assy.

Part Number

T-12A

Flow Control Spindle TA-10

1

IMPORTANT: Model numbers ending in TRMTC coordinate with Temptrol pressure balancing valves ordered with Test Cap. The Test Cap is used to allow pressurization of system. Do not remove test cap from valve during wall construction, installation of valve or pressurization of system.

PACKING

NUT

FIGURE 3

WARNINGS:

1. Test cap rated for pressure testing up to 200 psi maximum. DO NOT exceed 200 psi while pressure testing valve body.

2. Do not expose valve with test cap to heat for longer than 2 minutes when soldering copper tubing. Doing so may damage the internal components of the valve and will void the product warranty.

3. Ensure test cap is re-torqued to 30 lb-ft after soldering valve body.

4. Installation - Remove Test Cap (Model Numbers Ending in TRMTC)

Flow control spindle (TA-10) and cap assembly (T-12A) will come factory assembled for all model numbers ending in

TRMTC . When ready to remove Test Cap and install trim, follow the instructions below:

1) Check for leaks around the valve assembly and all pipe fittings.

2) Remove test cap from valve (FIGURE 4.1).

3) If system is dirty, flush valve.

4) Thread flow control spindle and cap assembly into valve body. Turn clockwise to secure to valve (FIGURE 4.2).

FIGURE 4.1

FIGURE 4.2

5. Installation - Adjust Packing Nut (Model Numbers Ending in TRMTC)

1) Turn hot and cold supplies on. Valve will not operate unless both hot and cold water supply pressures are on.

2) Place handle over flow control spindle.

3) Tighten packing nut for positive frictional resistance as handle is rotated from shut-off position across adjustment range.

6. Installation - Setting Limit Stop Screw (Model Numbers Ending in TRMTC)

The temperature limit stop screw limits valve handle from being turned to maximum position resulting in excessive hot water discharge temperatures.

WARNING: Failure to adjust limit stop screw properly may result in serious scalding.

1) Turn hot and cold supplies on. Valve will not operate unless both hot and cold water supply pressures are on.

2) Place handle on flow control spindle and open valve to maximum desired temperature.

3) Turn limit stop screw clockwise until it seats.

3

7. Parts Breakdown

FIGURE 7

A

B

O

L P Q

R

S

C

D

F

E

G

H

I

J

M

J

K

T

EF-109*

N

*Order in-line vacuum breaker (EF-109) for hand shower systems without dual checks.

M

N

O

P

Q

R

S

T

Item

A

B

C

D

E

F

I

J

K

L

G

H

Replacement Parts

Description Part Number

Showerhead 442SH

304 Shower Arm

Set Screw

Handle

Flange

O-ring

Lock Nut

Washer

Dome Cover

Mounting Screws

Escutcheon

Shower Plate

Diverter/Volume

Control Handle

Tub Spout

Hand Shower

Wall Cradle

Screws

Mounting Plate

Wall Elbow

60" Hose

DF-28-LPO

T-20-PL

40B-PL

DF-11

DF-14-SL

7.5-ETCH

DF-21/22

063

442W

EF-106

EF-105

RTS-045

Notes:

1) Append appropriate suffix for premium finish.

2) Append appropriate flow rate to showerhead or hand shower for low flow.

3) Apply a bead of silicone around the perimeter of all shower trim installed flush to the finished wall. Leave opening on bottom of escutcheons for weep hole.

4) Apply plumber tape to all threaded connections.

4

8. Installation - Shower Valve Trim

1) Place diverter/volume control handle into slot in shower escutcheon (FIGURE 8.1).

2) Secure escutcheon and shower plate to Temptrol pressure balancing valve using mounting screws. Guide handle into control port on valve body (FIGURE 8.2).

3) Install dome cover and washer to valve. Secure with lock nut by by turning clockwise (FIGURE 8.3).

4) Place o-ring in groove under spindle broach. Install flange and handle to shower valve. Secure with screw

(FIGURE 8.4).

FIGURE 8.1

FIGURE 8.3

9. Installation - Showerhead & Tub Spout

1) Attach shower arm to stub out pipe. Turn clockwise to tighten (FIGURE 9.1).

2) Install showerhead to shower arm. Turn clockwise to tighten (FIGURE 9.2).

3) Install tub spout to stub out pipe. Turn clockwise to tighten (FIGURE 9.3).

FIGURE 9.1

FIGURE 9.3

FIGURE 8.2

1

2

FIGURE 9.2

FIGURE 8.4

5

10. Installation - Slide Bar Assembly

1) Place mounting plate in position. Mark and drill 3/16" holes for tile anchors, 5/16" holes for drywall anchors.

Install anchors (FIGURE 10.1).

Note: For dry wall 1/2" thick or less, insert anchor tool into drywall anchor to secure behind wall prior to installing wall cradle.

2) Remove cover of hand shower cradle. Install cradle and mounting plate. Secure with three screws. Replace cover on hand shower cradle (FIGURE 10.2).

3) Install wall elbow to stub out pipe. Tighten set screw to secure (FIGURE 10.3).

4) Attach small end of hand shower hose to wall elbow.

Turn clockwise to tighten (FIGURE 10.4).

5) Attach large end of hand shower hose to hand shower wand. Turn clockwise to tighten (FIGURE 10.5).

FIGURE 10.1

1

3

4

TILE ANCHOR

2

DRY WALL ANCHOR

ANCHOR TOOL

FIGURE 10.3

1

2

4

FIGURE 10.4

FIGURE 10.2

3

FIGURE 10.5

6

11. Operation (Temperature Control)

1) Turn shower handle counter-clockwise approximately 1/4 turn to put valve in cold position (FIGURE 11.1).

2) Turn shower handle counter- clockwise approximately 1/2 turn to put valve in warm position (FIGURE 11.2).

3) Turn shower handle counter- clockwise approximately 3/4 turn to put valve in hot position (FIGURE 11.3).

FIGURE 11.1

12. Operation (VersaFlex™ Diverter Control)

Turn diverter control handle clockwise to divert to tub spout or other Symmons accessory .

Turn diverter control handle counterclockwise to divert to shower or other Symmons accessory .

FIGURE 12.1

FIGURE 11.2

TUB/ACCESSORY SHOWER/ACCESSORY

13. Operation (Volume Control)

Turn volume control handle clockwise to increase volume.

Turn volume control handle counterclockwise to decrease volume.

FIGURE 13.1

INCREASE DECREASE

FIGURE 11.3

7

14. Troubleshooting Chart

Problem

Finish is spotting.

Cause

Elements in water supply may cause water staining on finish.

Solution

Clean finished trim area with a soft cloth using mild soap and water or a non-abrasive cleaner and then quickly rinse with water.

WARNING: This product can expose you to chemicals including lead, which is known to the state of California to cause cancer, birth defects, or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.

Symmons Industries, Inc. ■ 31 Brooks Drive ■ Braintree, MA 02184 ■ Phone: (800) 796-6667 ■ Fax: (800) 961-9621

Copyright © 2020 Symmons Industries, Inc.

symmons.com

[email protected]

ZV-3408 REV 0

030220

advertisement

Related manuals

advertisement