Safety Tips
• Position on a flat, stable surface.
• A service agent/qualified technician should carry out installation and any repairs if required. Do not remove any components or service panels on this product.
• Consult Local and National Standards to comply with the following:
• Health and Safety at Work Legislation
• BS EN Codes of Practice
• Fire Precautions
• IEE Wiring Regulations
• Building Regulations
• DO NOT immerse in water, or use steam/jet washers to clean the unit.
• DO NOT cover the appliance when it is operating.
• DO NOT store food in the appliance.
• DO NOT use electrical appliances inside the appliance.
• Always carry, store and handle the appliance in a vertical position.
• Never tilt the appliance more than 45° from the vertical.
• Not suitable for outdoor use.
• Keep all packaging away from children. Dispose of the packaging in accordance with the regulations of local authorities.
• If the power cord is damaged, it must be replaced by a POLAR agent or a recommended qualified technician in order to avoid a hazard.
• This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilites, or lack of experience or knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
• Children should be supervised to ensure that they do not play with the appliance.
Product Description
• DL815-A - Single Door Back Bar Chiller
• DL816-A - Double Door Back Bar Chiller
• CF759-A - Double Door (Sliding) Back Bar Chiller
• DL818-A - Three Door Back Bar Chiller
• DL819-A - Three Door (Sliding) Back Bar Chiller
• CE205-A - Single Door Back Bar Chiller
• CE206-A - Double Door Back Bar Chiller
• CE207-A - Three Door Back Bar Chiller
• GJ447-A - Single Door Upright Back Bar Chiller
• GJ448-A - Double Door (Sliding) Upright Back Bar
Chiller
• GJ449-A - Double Door (Hinged) Upright Back Bar
Chiller
• CK479-A - Single Door Upright Back Bar Chiller
• CK478-A - Double Door (Sliding) Upright Back Bar
Chiller
• CK477-A - Double Door (Hinged) Upright Back Bar
Chiller
Telephone Helpline: 1300 225 960
Introduction
Please take a few moments to carefully read through this manual. Correct maintenance and operation of this machine will provide the best possible performance from your POLAR product.
Pack Contents
The following is included:
ALL MODELS
• POLAR Back Bar Chiller
• Key
• Instruction manual
Plus..
COUNTER MODELS
• 2 adjustable shelves per Door
UPRIGHT MODELS
• 4 adjustable shelves per Door
POLAR prides itself on quality and service, ensuring that at the time of packaging the contents are supplied fully functional and free of damage.
Should you find any damage as a result of transit, please contact your POLAR dealer immediately.
Installation
Note: If the unit has not been stored or moved in an upright position, let it stand upright for approximately 12 hours before operation. If in doubt allow to stand.
1.
Remove the appliance from the packaging and the protective film from all surfaces.
2.
Avoid positioning the appliance in direct sunlight or damp areas.
3.
Insert the slide-out shelf/shelves at the desired levels
4.
If necessary, adjust the screw feet of the appliance to make it level.
Note: Before using the appliance for the first time, clean the shelves and interior with soapy water.
Operation
Control Panel
The control panel is located below the doors on the front of the appliance.
Defrost Light Cooling Light
Turn On
1.
Close the door of the appliance.
2.
Connect the appliance to a mains power supply..
Note: The Cooling Light is illuminated when the appliance is chilling the interior cabinet.
To Change the Operating Temperature
The default operating temperature is 2 °C. To display the operating temperature (set point), press and immediately release the button.
To change the operating temperature;
1.
Press and Hold the button for 2 seconds, the “°C” will start to flash.
2.
Press the
3.
Press the
or buttons to change the temperature.
button to store the temperature.
Manual Defrost
POLAR Back Bar Chillers feature an automatic defrost. However, should the appliance require an additional defrost period press and hold the button for 2 seconds.
Automatic defrost cycles are every 6 hours and last 20 minutes (factory defaults).
Note: If a manual defrost is started this resets the automatic defrost timer. During defrost periods the Defrost light is illuminated.
Cleaning, Care & Maintenance
• Switch off and disconnect from the power supply before cleaning.
• Clean the interior of the appliance as often as possible.
• Do not use abrasive cleaning agents. These can leave harmful residues.
• Always wipe dry after cleaning.
• A POLAR agent or qualified technician must carry out repairs if required.
Cleaning the Condenser
Periodically cleaning the condenser can extend the life of the appliance. The condenser is located at the back of the appliance.
Note: Use a soft brush or vacuum cleaner to clean the fins of the condenser, taking care not to damage the fins.
Telephone Helpline: 1300 225 960
Troubleshooting
If your appliance develops a fault, please check the following table before making a call to the Helpline.
Fault
The appliance is not working
The appliance turns on, but the temperature is too high/low
The appliance is unusually loud
Probable Cause
The unit is not switched on
Plug and lead are damaged
Fuse in the plug has blown
Power supply
Internal wiring fault
Condenser blocked with dust
Doors are not shut properly
Appliance is located near a heat source or air flow to the condenser is being interrupted
Ambient temperature is too high
Action
Check the unit is plugged in correctly and switched on
Call POLAR agent or qualified Technician
Replace the fuse
Check power supply
Call POLAR agent or qualified Technician
Clean Condenser
Check doors are shut and seals are not damaged
Move the appliance to a more suitable location
Insufficient airflow to the fans
Appliance is overloaded
Factory default parameters adjusted
The appliance is touching a neighbouring object
The appliance has not been installed in a level or stable position
Increase ventilation or move appliance to a cooler position
Remove any blockages to the fans
Reduce the amount stored in the appliance
Call POLAR agent or qualified Technician
Check installation position and change if necessary
Check installation position and change if necessary
Technical Specifications
Model Voltage Power Current Temperature
DL815-A 230V 50Hz 160W
DL816-A 230V 50Hz 280W
CF759-A 230V 50Hz 280W
DL818-A 230V 50Hz 315W
DL819-A 230V 50Hz 315W
CE205-A 230V 50Hz 160W
CE206-A 230V 50Hz 280W
CE207-A 230V 50Hz 315W
GJ447 230V 50Hz 300W
GJ448 230V 50Hz 400W
GJ449 230V 50Hz 400W
CK479-A 230V 50Hz 300W
CK477-A 230V 50Hz 400W
CK478-A 230V 50Hz 400W
1.1A
1.8A
1.8A
1.9A
1.9A
1.1A
1.8A
1.9A
1.2A
1.5A
1.5A
1.2A
1.5A
1.5A
2°C to 8°C
2°C to 8°C
2°C to 8°C
2°C to 8°C
2°C to 8°C
2°C to 8°C
2°C to 8°C
2°C to 8°C
2°C to 8°C
2°C to 8°C
2°C to 8°C
2°C to 8°C
2°C to 8°C
2°C to 8°C
Capacity
(litres)
335
307
490
490
307
490
490
134
210
210
320
320
140
223
Refrigerant
Dimensions
H x W x D (mm)
R134a 140g
R134a 140g
R134a 140g
870 x 600 x 535
870 x 900 x 535
870 x 900 x 535
R134a 150g 870 x 1350 x 535
R134a 150g 870 x 1350 x 535
R134a 140g
R134a 140g
870 x 600 x 540
870 x 900 x 540
R134a 150g 870 x 1350 x 540
R134a 180g 1880 x 600 x 514
R134a 240g 1880 x 920 x 514
R134a 240g 1880 x 920 x 514
R134a 180g 1880 x 600 x 514
R134a 240g 1880 x 920 x 514
R134a 240g 1880 x 920 x 514
Weight
(kg)
95
112
143
140
112
143
140
85
85
54
75
50
62
62
Electrical Wiring
The plug is to be connected to a suitable mains socket.
This appliance is wired as follows:
• Live wire (coloured brown) to terminal marked L
• Neutral wire (coloured blue) to terminal marked N
• Earth wire (coloured green/yellow) to terminal marked E
This appliance must be earthed, using a dedicated earthing circuit.
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency disconnection being required they must be readily accessible.
Disposal
EU regulations require refrigeration product to be disposed of by specialist companies who remove or recycle all gasses, metal and plastic components.
Consult your local waste collection authority regarding disposal of your appliance. Local authorities are not obliged to dispose of commercial refrigeration equipment but may be able to offer advice on how to dispose of the equipment locally.
Alternatively call the POLAR helpline for details of national disposal companies within the EU.
Compliance
The WEEE logo on this product or its documentation indicates that the product must not be disposed of as household waste. To help prevent possible harm to human health and/or the environment, the product must be disposed of in an approved and environmentally safe recycling process. For further information on how to dispose of this product correctly, contact the product supplier, or the local authority responsible for waste disposal in your area.
POLAR parts have undergone strict product testing in order to comply with regulatory standards and specifications set by international, independent, and federal authorities.
POLAR products have been approved to carry the following symbol:
All rights reserved. No part of these instructions may be produced or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written permission of POLAR.
Every effort is made to ensure all details are correct at the time of going to press, however, POLAR reserve the right to change specifications without notice.
DECLARATION OF
Equipment Type Refrigerator / Freezer
Model DL815-A CF759-A DL816-A DL818-A DL819-A CK477-A
CK478-A CK479-A, CE205-A, CE206-A, CE207-A
Legislation
Standards
C-Tick
AS/NZ 3820 Essential Safety Requirements for Low Voltage
Electrical Equipment
MEPS
EN 55014-1:2006, EN 55014-2:1997+A1
EN 61000-3-2:2006,
EN 61000-3-3:1995+A1+A2, EN 61000-3-11:2000,
EN 55015:2006, EN 61547:1995+A1
AS/NZS 60335.2.89:2002+A1:2003+A2:2005+A3:2007 with:
AS/NZS 60335.1:2002+A1:2004+A2:2007+A3:2007
AS 1731.14 :2003
Producer Name
Producer
Address
POLAR
15 Badgally Road,
Campbelltown,
NSW 2560
I, the undersigned, hereby declare that the equipment specified above conforms to the above Legislation and Standard(s).
Date 28/03/11
Signature
Full Name Richard Cromwell
Backbar_Coolers-A.v5
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 2 Safety Tips
- 2 Product Description
- 3 Introduction
- 3 Pack Contents
- 3 Installation
- 3 1. Remove the appliance from the packaging and the protective film from all surfaces.
- 3 2. Avoid positioning the appliance in direct sunlight or damp areas.
- 3 3. Insert the slide-out shelf/shelves at the desired levels
- 3 4. If necessary, adjust the screw feet of the appliance to make it level.
- 3 Operation
- 3 Control Panel
- 3 The control panel is located below the doors on the front of the appliance.
- 3 Turn On
- 3 1. Close the door of the appliance.
- 3 2. Connect the appliance to a mains power supply..
- 4 To Change the Operating Temperature
- 4 1. Press and Hold the button for 2 seconds, the “˚C” will start to flash.
- 4 2. Press the or buttons to change the temperature.
- 4 3. Press the button to store the temperature.
- 4 Manual Defrost
- 4 Cleaning, Care & Maintenance
- 4 Cleaning the Condenser
- 5 Troubleshooting
- 5 Technical Specifications
- 6 Electrical Wiring
- 6 Disposal
- 6 Alternatively call the POLAR helpline for details of national disposal companies within the EU.
- 6 Compliance
- 6 All rights reserved. No part of these instructions may be produced or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written permission of POLAR.