USER MANUAL

Add to my manuals
12 Pages

advertisement

USER MANUAL | Manualzz

www.prolight.co.uk

(Order code: LEDJ220)

USER MANUAL

ARCHI BAR 16 TRI SAFETY

WARNING

FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY

BEFORE YOUR INITIAL START-UP!

SAFETY INSTRUCTIONS

Every person involved with the installation, operation & maintenance of this equipment should:

-

-

Be competent

Follow the instructions of this manual

CAUTION! TAKE CARE USING THIS EQUIPMENT!

HIGH VOLTAGE-RISK OF ELECTRIC SHOCK!!

Before your initial start-up, please make sure that there is no damage caused during transportation. Should there be any, consult your dealer and do not use the equipment.

To maintain the equipment in good working condition and to ensure safe operation, it is necessary for the user to follow the safety instructions and warning notes written in this manual.

Please note that damages caused by user modifications to this equipment are not subject to warranty.

1.

ARCHI BAR 16 TRI SAFETY

IMPORTANT:

The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorised modification to the equipment.

• Never let the power-cable come into contact with other cables. Handle the power-cable

and all mains voltage connections with particular caution!

• Never remove warning or informative labels from the equipment.

• Do not open the equipment and do not modify the equipment.

• Do not connect this equipment to a dimmer-pack.

• Do not switch the equipment on and off in short intervals, as this will reduce the

system’s life.

• Do not expose to flammable sources, liquids or gases.

• Always disconnect the power from the mains when equipment is not in use or before

cleaning! Only handle the power-cable by the plug. Never pull out the plug by pulling the

power-cable.

• Make sure that the available voltage is between 220v/240v.

• Make sure that the power-cable is never crimped or damaged. Check the equipment and

the power-cable periodically.

• If the equipment is dropped or damaged, disconnect the mains power supply immediately.

Have a qualified engineer inspect the equipment before operating again.

• If your product fails to function correctly, discontinue use immediately. Pack the unit

securely (preferably in the original packing material), and return it to your Prolight dealer

for service.

• Only use fuses of same type and rating.

• Repairs, servicing and power connection must only be carried out by a qualified

technician. THIS UNIT CONTAINS NO USER SERVICEABLE PARTS.

• WARRANTY; One year from date of purchase.

OPERATING DETERMINATIONS

If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and the warranty becomes void.

Incorrect operation may lead to danger e.g.: short-circuit, burns, electric shocks, lamp failure etc.

Do not endanger your own safety and the safety of others!

Incorrect installation or use can cause serious damage to people and property.

2.

ARCHI BAR 16 TRI

Introduction

Features

• DMX channels: 6/9/15 selectable

• 16 x Ultra Bright 3W Tri colour LEDs

• 14 built-in programmes

• 4 push button LCD display

• Master/Slave functions

• Auto run mode

• Power in/out connections

• DMX in/out connections

• Consumption: 53W

• Beam 25 degrees

• IP Rating: IP65

• Power supply: 240V

• Dimensions: 400 x 120 x 175mm

• Weight: 5.3Kgs

Overview

INTRODUCTION

LCD DISPLAY

DMX

IN

POWER

IN

DMX

OUT

POWER

OUT

Setup

Operating Instructions

The Archi Bar 16 Tri is a DMX-512 controllable unit made up of high efficiency and Ultra Bright

Tri-colour LEDs and will operate in stand alone, master/slave or DMX control modes.

3.

ARCHI BAR 16 TRI OPERATION MODES

Operation modes

Auto run mode:

To activate the unit in auto run mode, press the “MODE” button to show “AUTO RUN” on the

LCD screen. Now press the “ENTER” button to select the desired frequency level by using the

“UP” and “DOWN” buttons.

“FQN” 01-99 (01 = low, 99 = high)

Note: In this mode, it will run 13 built-in programmes in a continious loop.

Slave mode:

To activate the unit in slave mode, first you must link multiple units together and press the

“MODE” button to show “SLAVE MODE” on the LCD screen. Now on the master unit press the

“MODE” button to select the desired mode and the slave units will now run in sequence with the master unit.

Built-in programmes:

To activate the units built-in programmes, press the “MODE” button to show “01.STATIC” on the

LCD screen. Press the “ENTER” button to choose between the 14 built-in programmes by using the “UP” and “DOWN” buttons. Now press the “ENTER” button to select the desired speed and adjust by using the “UP” and “DOWN” buttons. Press the “ENTER” button once more to select the desired flash value and adjust by using the “UP” and “DOWN” buttons.

Speed values: 00 - 99 (00 = slow, 99 = fast)

Flash values: 00 - 99 (00 = slow, 99 = fast)

For the 14 built-in programmes please see page 5.

DMX mode:

To activate the unit in DMX mode, press the “MODE” button to show “DMX MODE” on the LCD screen. Press the “ENTER” button and select the desired DMX address setting by using the “UP” and “DOWN” buttons. Then to select one of the 3 DMX modes 15, 9 or 6 channel, press the “ENTER” button again to choose the desired DMX mode by using the “UP” and

“DOWN” buttons.

For the 6, 9, and 15 channel DMX address information please see pages 6 & 7.

NOTE: Once the desired settings have been selected in each of the above modes,

ALWAYS

confirm the settings by pressing the “ENTER” button.

4.

ARCHI BAR 16 TRI

14 Built-in programme chart

BUILT-IN PROGRAMME CHART

STATIC COLOR

BLACKOUT - RGB

Flash00-99

DREAM

Speed 00-99 Flash 00-99

METEOR

Speed 00-99 Flash 00-99

FADE

Speed 00-99 Flash 00-99

CHANGE

Speed 00-99 Flash 00-99

FLOW 1

Speed 00-99 Flash 00-99

FLOW 2

Speed 00-99 Flash 00-99

FLOW 3

Speed 00-99 Flash 00-99

FLOW 4

Speed 00-99 Flash 00-99

FLOW 5

Speed 00-99 Flash 00-99

FLOW 6

Speed 00-99 Flash 00-99

FLOW 7

Speed 00-99 Flash 00-99

FLOW 8

Speed 00-99 Flash 00-99

1.BLA-RGB 2. BLA-RGB

FLOW 9

Speed00-99 Flash 00-99

1.BLA-RGB 2. BLA-RGB

BLA=Blackout, R=Red, RG=Yellow, G=Green,

GB=Cyan, B=Blue, BR=Purple, RGB=White

Flash speed adjustable.

Seven colour fade

Speed & Flash adjustable

Seven colour flow

Speed & Flash adjustable

Seven colour fade in, fade out

Speed & Flash adjustable

Seven colour change

Speed & Flash adjustable

Seven colour chase (forward)

Speed & Flash adjustable

Seven colour chase (forward & reverse)

Speed & Flash adjustable

Seven colour fade chase in relay pattern (forward)

Speed & Flash adjustable

Seven colour fade chase in relay pattern (forward & reverse)

Speed & Flash adjustable

Seven colour chase from sides to centre

Speed & Flash adjustable

Seven colour chase from centre to sides

Speed & Flash adjustable

Seven colour rotating chase

Speed & Flash adjustable

Two colour chase (forward)

Speed & Flash adjustable

Blackout, Red, Yellow, Green, Cyan, Blue, Purple,

White

Two colour chase (forward & reverse)

Speed & Flash adjustable

BLA=Blackout, R=Red, RG=Yellow, G=Green,

GB=Cyan, B=Blue, BR=Purple, RGB=White

5.

ARCHI BAR 16 TRI DMX PROGRAMME CHARTS

6 channel mode DMX chart

CH 1

0-10

11-21

CH 2

Blackout

Master dimmer

(0-255)

CH3

Blackout

Flash

(0-255)

CH4

Blackout

All Red

LEDs

(0-255)

22-32 Red

33-43 Yellow

44-54 Green

55-65 Cyan

66-76 Blue

77-87 Purple

88-98 White

Flash(0-255)

Flash (0-255)

Flash (0-255)

Flash (0-255)

Flash (0-255)

Flash (0-255)

Flash (0-255)

99-109 Dream Speed (0-255) Flash (0-255)

110-120 Meteor Speed (0-255) Flash (0-255)

121-131 Fade Speed (0-255) Flash (0-255)

132-142 Change Speed (0-255) Flash (0-255)

143-153 Flow 1 Speed (0-255) Flash (0-255)

154-164 Flow 2 Speed (0-255) Flash (0-255)

165-175 Flow 3 Speed (0-255) Flash (0-255)

176-186 Flow 4 Speed (0-255) Flash (0-255)

187-197 Flow 5 Speed (0-255) Flash (0-255)

198-208 Flow 6 Speed (0-255) Flash (0-255)

209-219 Flow 7 Speed (0-255) Flash (0-255)

220-230 Flow 8 Speed (0-255) Flash (0-255 Colour select

231-241 Flow 9 Speed (0-255) Flash (0-255) Colour select

242-255

No function

Speed (0-255) Flash (0-255)

CH5

Blackout

All Green

LEDs

(0-255)

Colour select

Colour select

9 channel mode DMX chart

CH6

Blackout

All Blue

LEDs

(0-255)

15 channel mode DMX chart

CH4 CH5 CH6 CH7 CH8 CH9 CH10 CH11 CH12 CH13 CH14 CH15

R1 G1 B1 R2 G2 B2 R3 G3 B3 R4 G4 B4

Note: DMX values from 0 - 10 and 22 - 255 also apply to the 9 and 15 channel modes.

6.

ARCHI BAR 16 TRI DMX SET UP

DMX-512:

• DMX (Digital Multiplex) is a universal protocol used as a form of communication between

intelligent fixtures and controllers. A DMX controller sends DMX data instructions form the

controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture via the

DATA “IN” and DATA “OUT” XLR terminals located on all DMX fixtures (most controllers only

have a data “out” terminal).

DMX Linking:

• DMX is a language allowing all makes and models of different manufactures to be linked together

and operate from a single controller, as long as all fixtures and the controller are DMX compliant.

To ensure proper DMX data transmission, when using several DMX fixtures try to use the

shortest cable path possible. The order in which fixtures are connected in a DMX line does not

influence the DMX addressing. For example; a fixture assigned to a DMX address of 1 may be

placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a

fixture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to

address 1 to that unit, no matter where it is located in the DMX chain.

DATA Cable (DMX cable) requirements (for DMX operation):

• The Archi Bar 16 Tri can be controlled via DMX-512 protocol. The DMX address is set on the

back of the unit. Your unit and your DMX controller require a standard 3-pin XLR connector for

data input/output (figure 1).

Figure 1

Further DMX cables can be purchased from all good sound and lighting suppliers or Prolight dealers.

Please quote:

CABL10 – 2M

CABL11 – 5M

CABL12 – 10M

Also remember that DMX cable must be daisy chained and cannot be split.

7.

ARCHI BAR 16 TRI DMX SET UP

Notice:

• Be sure to follow figures 2 & 3 when making your own cables. Do not connect the cable’s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR’s outer casing. Grounding the shield could cause a short circuit and erratic behaviour.

Special Note: Line termination:

• When longer runs of cable are used, you may need to use a terminator on the last unit to

avoid erratic behaviour.

Termination reduces signal transmission problems and interferance. it is always advisable to connect a

DMX terminal, (resistance 120 Ohm 1/4 W) between pin 2 (DMX-) and pin 3 (DMX+) of the last fixture.

Using a cable terminator (part number CABL90) will decrease the possibilities of erratic behaviour.

5-Pin XLR DMX Connectors:

• Some manufactures use 5-pin XLR connectors for data transmission in place of 3-pin. 5-Pin

XLR fixtures may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin

XLR connectors in to a 3-pin line a cable adaptor must be used. The chart below details the

correct cable conversion.

8.

ARCHI BAR 16 TRI TECHNICAL SPECIFICATIONS

Technical Specifications

Weight & Dimensions

• Length…............................................................400mm

• Width..................................................................120mm

• Height……………………………………………...175mm

• Weight………………………………………..........5.3Kgs

Power

• AC input……………………………………..........240V/50hz

• Power consumption.........................................53W

• Fuse

• Main………………………………………………...F2A

Control & Programming

• Data input………………………………………....Locking 3-pin XLR male socket

• Data output………………………………………..Locking 3-pin XLR female socket

• Protocols………………………………………….DMX-512 UTSITT

• DMX channels…………………………………....15, 9 and 6

9.

10.

www.prolight.co.uk

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement