Endres+Hauser Tankvision NXA820, NXA821, NXA822 Operating Instruction


Add to my manuals
230 Pages

advertisement

Endres+Hauser Tankvision NXA820, NXA821, NXA822 Operating Instruction | Manualzz

BA00339G/00/EN/14.13

71241952

Valid as of software version:

01.05.00

Products Solutions Services

Description of Instrument Functions

Tankvision

Tank Scanner NXA820, Data

Concentrator NXA821, Host Link

NXA822

Inventory Control

Tankvision

Table of Contents

1 Document information . . . . . . . . . . . . . . 4

1.1 Target audience for this manual . . . . . . . . . . . . . . . 4

1.2 Version history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

1.3 Document function . . . . . . . . . . . . . . . . . . . . . . . . . . 4

1.4 Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

2 Basic safety instructions . . . . . . . . . . . . 7

2.1 Requirements for the personnel . . . . . . . . . . . . . . . 7

2.2 IT security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

2.3 Designated use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

2.4 Workplace safety . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

2.5 Operational safety . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

2.6 Product safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

3 Getting Started. . . . . . . . . . . . . . . . . . . . . 9

3.1 Introduction to the Tankvision system . . . . . . . . . . 9

3.2 The Tankvision User Interface . . . . . . . . . . . . . . . 11

3.3 Logging into the Tankvision system . . . . . . . . . . 14

3.4 Common settings - Tankvision system . . . . . . . . 15

4 The Tankvision Operating Screens. . . 35

5 The "Tanks" menu - Tank Details . . . . 37

5.1 General Details . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

5.2 Capacity Details . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

5.3 Shell Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

5.4 Floating Roof . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

5.5 Flow Calculation . . . . . . . . . . . . . . . . . . . . . . . . . . 49

5.6 Water Content . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

5.7 Hybrid Tank Measurement System . . . . . . . . . . 52

5.8 Inventory Calculation . . . . . . . . . . . . . . . . . . . . . . 53

5.9 Put Tank into Calibrated Status . . . . . . . . . . . . . 54

5.10 HART command . . . . . . . . . . . . . . . . . . . . . . . . . . 55

6 The "Tanks" menu - Alarm Settings. . 56

6.1 Measured Data Alarm Configuration . . . . . . . . . 57

6.2 Calculated Data Alarm Configuration . . . . . . . . 59

7 The "Tanks" menu - Gauge

Commands . . . . . . . . . . . . . . . . . . . . . . . 61

8 The Tank Details screen. . . . . . . . . . . . 63

8.1 The "General Details" tab . . . . . . . . . . . . . . . . . . . . 64

8.2 The "Spot Temperature" tab . . . . . . . . . . . . . . . . . 66

8.3 The "Manual Data" tab . . . . . . . . . . . . . . . . . . . . . 67

8.4 The "Dipped Data" tab . . . . . . . . . . . . . . . . . . . . . . 68

8.5 The "Gauge Commands" tab . . . . . . . . . . . . . . . . . 69

8.6 The "Real Time Trend" tab . . . . . . . . . . . . . . . . . . 73

8.7 The "Product Transfer" tab . . . . . . . . . . . . . . . . . . 75

8.8 The "Tank Status" tab . . . . . . . . . . . . . . . . . . . . . . 84

8.9 The "Assign Product" tab . . . . . . . . . . . . . . . . . . . . 87

2

8.10 The "Product Transfer Report" tab . . . . . . . . . . . . . 88

8.11 The "Tank Calculator" tab . . . . . . . . . . . . . . . . . . . . 90

9 The "Products" menu . . . . . . . . . . . . . . .91

9.1 Adding, Modifying and Deleting Products . . . . . 91

9.2 View Product Tank Groups . . . . . . . . . . . . . . . . 101

10 The "Customized Groups" menu. . . . 105

10.1 Static Tank Group . . . . . . . . . . . . . . . . . . . . . . . . 106

10.2 Dynamic Tank Group . . . . . . . . . . . . . . . . . . . . . 107

10.3 Modify Tank Groups . . . . . . . . . . . . . . . . . . . . . . 108

10.4 Delete Tank Groups . . . . . . . . . . . . . . . . . . . . . . 109

10.5 View Real Time Tank Group Details . . . . . . . . . 110

11 The "Transfers" menu . . . . . . . . . . . . 114

11.1 Graphical View of the Product Transfer Group

Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115

11.2 Tabular View of the Product Transfer Group

Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115

12 The "System" menu . . . . . . . . . . . . . . 116

12.1 Customer Settings . . . . . . . . . . . . . . . . . . . . . . . . 117

12.2 Network Setting . . . . . . . . . . . . . . . . . . . . . . . . . 128

12.3 Environment Settings . . . . . . . . . . . . . . . . . . . . 134

12.4 Trend Global Settings . . . . . . . . . . . . . . . . . . . . . 135

12.5 Field Scan - Modbus EIA485 . . . . . . . . . . . . . . . 136

12.6 Configure Field Scan - Sakura V1 . . . . . . . . . . . 141

12.7 Configure Field Scan - Whessoe WM550 . . . . 146

12.8 W&M Seal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151

12.9 Data Archival . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153

12.10 Tank Scanner Unit and Tank Assignment . . . . 160

12.11 Host Link . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161

12.12 Downloads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181

12.13 Operator Workstation Settings . . . . . . . . . . . . . 185

12.14 System Diagnostics . . . . . . . . . . . . . . . . . . . . . . . 187

12.15 Uploads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189

12.16 Device Status Codes . . . . . . . . . . . . . . . . . . . . . . 196

12.17 Tankvision Outputs . . . . . . . . . . . . . . . . . . . . . . 197

13 The "Reports" menu . . . . . . . . . . . . . . 198

13.1 Select NXA820 Configuration Details . . . . . . . 199

13.2 Select Product Transfer Details . . . . . . . . . . . . . 199

13.3 Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200

13.4 Alarm Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200

13.5 Select Tanks For Tank Report . . . . . . . . . . . . . . 201

13.6 Select Tanks For Tank Detail Report . . . . . . . . 201

13.7 Select Tank Groups For Report . . . . . . . . . . . . . 202

13.8 Select Inventory Report . . . . . . . . . . . . . . . . . . . 202

14 The "Users" menu . . . . . . . . . . . . . . . . 203

14.1 Manage Users . . . . . . . . . . . . . . . . . . . . . . . . . . . 203

14.2 Managing the User Access Rights . . . . . . . . . . 207

Endress+Hauser

Tankvision

15 Historical Trend . . . . . . . . . . . . . . . . . .209

16 KPI Dashboards . . . . . . . . . . . . . . . . . .211

16.1 Starting KPI Dashboards . . . . . . . . . . . . . . . . . . 211

16.2 Global Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . 211

16.3 Tank Turn Over KPI . . . . . . . . . . . . . . . . . . . . . . 212

16.4 Safety Stock KPI . . . . . . . . . . . . . . . . . . . . . . . . . . 212

16.5 Free Stock KPI for Tanks . . . . . . . . . . . . . . . . . . 213

16.6 Free Stock KPI for Groups . . . . . . . . . . . . . . . . . 214

16.7 Percentage of Products KPI . . . . . . . . . . . . . . . . 214

16.8 Errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215

17 The Alarm and Event Panel . . . . . . . .217

17.1 Overview of the Alarm and Event Panel . . . . . 217

17.2 Types of Alarms . . . . . . . . . . . . . . . . . . . . . . . . . 220

17.3 Alarm Color Schemes . . . . . . . . . . . . . . . . . . . . . 220

17.4 Acknowledging an Alarm . . . . . . . . . . . . . . . . . 222

18 Other Global Setting . . . . . . . . . . . . . .223

19 Comm DTM for FieldCare . . . . . . . . . .225

Index. . . . . . . . . . . . . . . . . . . . . . . . . . . .226

Endress+Hauser 3

Document information Tankvision

1 Document information

1.1

Target audience for this manual

This manual is giving detailed information on the system capabilities and architecture. It supports project and sales engineers in designing the system architecture during acquisition and execution phase. Furthermore the needed service information during system operation can be retrieved by servicing personnel.

This manual should support the operating personal working on a regular basis with the Tank

Gauging System understanding the possible tasks they have to perform and should serve as encyclopedia for those tasks.

This manual is for day to day use of the Tankvision system. This manual will help in configuring and using the Tankvision system.

Beside basic PC operating knowledge no special training is needed to perform the Tank

Gauging System operations. Nevertheless it is recommended receiving a training on the system by Endress+Hauser.

1.2

Version history

Document version

BA00339G/00/EN/05.08

BA00339G/00/EN/12.09

BA00339G/00/EN/13.12

BA00339G/00/EN/14.13

Valid for SW version

01.01.01

01.02.00

01.02.02

01.05.00 onwords

Changes to the previous version initial version

Edition weight and measures system

Hybrid tank management and changes in TCT

Introducing "Interface only" version, new layout

1.3

Document function

1.3.1

Used symbols

Safety symbols

Symbol

DANGER

A0011189-EN

WARNING

A0011190-EN

CAUTION

A0011191-EN

Meaning

DANGER!

This symbol alerts you to a dangerous situation. Failure to avoid this situation will result in serious or fatal injury.

WARNING!

This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in serious or fatal injury.

CAUTION!

This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in minor or medium injury.

NOTICE

A0011192-EN

NOTICE!

This symbol contains information on procedures and other facts which do not result in personal injury.

4 Endress+Hauser

Tankvision Document information

Electrical symbols

Symbol Meaning

Direct current

A terminal to which DC voltage is applied or through which direct current flows.

A0011197

Alternating current

A terminal to which alternating voltage is applied or through which alternating current flows.

A0011198

)

A0011200

*

A0011199

Ground connection

A grounded terminal which, as far as the operator is concerned, is grounded via a grounding system.

Protective ground connection

A terminal which must be connected to ground prior to establishing any other connections.

Symbols for certain types of information

Symbol Meaning

Tip

Indicates additional information.

A0011193

Reference to page

Refers to the corresponding page number.

A0011195

1. 2.

,

3.

... Series of steps

Result of a sequence of actions

A0018373

Symbols in graphics

Symbol

-

A0011187

Meaning

1, 2, 3 ...

Item numbers

1. 2.

,

3.

... Series of steps

A, B, C ...

Views

Hazardous area

Indicates a hazardous area.

.

A0011188

Indicates a non-hazardous location

Safe area (non-hazardous area)

Endress+Hauser 5

Document information

1.4

Documentation

1.4.1

Operating instructions

Instrument Document number

BA00339G/00

BA00340G/00

BA00424G/00

BA00426G/00

BA01137G/00

• Tank Scanner NXA820

• Data Concentrator NXA821

• Host Link NXA822

Tankvision NXA820 OPC Server

Type of Document

Description of Instrument Functions

Installation Instructions

System Description

Operator Manual

User Manual

Tankvision

6 Endress+Hauser

Tankvision

Endress+Hauser

Basic safety instructions

2 Basic safety instructions

2.1

Requirements for the personnel

The personnel for installation, commissioning, diagnostics and maintenance must fulfill the following requirements:

• Trained, qualified specialists: must have a relevant qualification for this specific function and task

• Are authorized by the plant owner/operator

• Are familiar with federal/national regulations

• Before beginning work, the specialist staff must have read and understood the instructions in the Operating Instructions and supplementary documentation as well as in the certificates

(depending on the application)

• Following instructions and basic conditions

The operating personnel must fulfill the following requirements:

• Being instructed and authorized according to the requirements of the task by the facility's owner operator

• Following the instructions in these Operating Instructions

2.2

IT security

We only provide a warranty if the device is installed and used as described in the Operating

Instructions. The device is equipped with security mechanisms to protect it against any inadvertent changes to the device settings.

IT security measures in line with operators' security standards and designed to provide additional protection for the device and device data transfer must be implemented by the operators themselves.

Endress+Hauser can be contacted to provide support in performing this task.

2.3

Designated use

2.3.1

Application

Tankvision is a dedicated tank inventory management system.

Components:

• Tankvision Tank Scanner NXA820 scans parameters from tank gauges and performs tank calculations

• Tankvision Data Concentrator NXA821 summarizes data from various Tank Scanners NXA820

• Tankvision Host Link NXA822 provides data to host systems (such as PLC or DCS) via Modbus

The above mentioned components are operated via a standard web browser. It does not require any proprietary software. Tankvision is based on a distributed architecture on a Local

Area Network (LAN). Due to its modular structure it can be adjusted to any application. It is ideally suited for small tank farms with only a couple of tanks, but also for large refineries with hundreds of tanks.

2.4

Workplace safety

For work on and with the device:

7

Basic safety instructions Tankvision

• Wear the required personal protective equipment according to federal/national regulations.

• Switch off the supply voltage before connecting the device.

2.5

Operational safety

Risk of injury!

• Operate the device in proper technical condition and fail-safe condition only.

• The operator is responsible for interference-free operation of the device.

Conversions to the device

Unauthorized modifications to the device are not permitted and can lead to unforeseeable dangers

• If, despite this, modifications are required, consult with Endress+Hauser.

Repair

To ensure continued operational safety and reliability,

• Carry out repairs on the device only if they are expressly permitted.

• Observe federal/national regulations pertaining to repair of an electrical device.

• Use original spare parts and accessories from Endress+Hauser only.

2.6

Product safety

The device is designed to meet state-of-the-art safety requirements, has been tested and left thefactory in a condition in which it is safe to operate. The device complies with the applicable standards and regulations as listed in the EC declaration of conformity and thus complies with the statutory requirements of the EG directives. Endress+Hauser confirms the successful testing of the device by affixing to it the CE mark.

8 Endress+Hauser

Tankvision Getting Started

3 Getting Started

3.1

Introduction to the Tankvision system

Tankvision is a tank inventory control system. Based on extensive engineering services, intelligent field device configuration, standardized bus technology and trend-setting software solutions, a web based system has been devised for the optimization of storage and delivery processes with Inventory and Process Control. This system provides tank inventory data to end users. Tank inventory control systems are mainly used in oil, gas, and petrochemical industries.

Tankvision allows worldwide access to inventory data. This enhances storage area optimization and improves logistics between the vendor and the final customer. Tankvision archives the inventory data for historical reports. Tankvision also manages product transfers and generates product transfer reports.

3.1.1

System Features

Tankvision is a web-based system running over the Intranet. The system provides an easy to use, GUI based multi-lingual interface. All you need is a web-browser to configure and view the system.

Tankvision acquires measured data such as level, temperature, pressure and density from field gauges. It then calculates tank inventory data such as product volume, mass, etc.

A list of Tankvision features is as follows:

• Provides measured data

• Performs inventory calculations

• Provides calculated inventory data

• Displays real-time trends and historical trends

• Displays and prints inventory reports

• Displays alarm and event notifications

As a system, Tankvision provides:

• Web based interface

• Minimum configurations to get started

• No additional software to be installed

• Redundancy (planned)

• Pan caking of features to suite all kinds of installations

• Scalable

• Interface through standard network protocols

• Customizable web pages

• W&M compliance

• Inventory and Product Transfer Reports

• Multilingual user interface

Endress+Hauser 9

Getting Started Tankvision

3.1.2

System components

The Tankvision system is physically divided into separate units. Each unit is responsible for a specific operation. All Tankvision units are connected together through an Ethernet link.

The architecture for the Tankvision system is shown in the figure as follows:

NXA821

Data Concentrator

NXA822

Host Link

Host Computer

NXA820

Tank Scanner

(with inventory calculations)

L00-NXA820xx-14-00-00-en-002

Unit

NXA820

Tank Scanner

NXA821

Data Concentrator

NXA822

Host Link

Description

• Captures measured data from the gauges installed on tanks.

• Provides measured data to other Tankvision units and visualization to end users.

• Provides the real-time trend of the measured data.

• Includes inventory calculations.

• Stores measured and calculated inventory data for a certain amount of time.

• Generates inventory reports and historical trends.

• Provides a single entrance point to Tankvision systems with several NXA820 units.

• Enables grouping of tanks regardless to which NXA820 unit they are connected.

• Provides a Modbus link (serial Modbus or Modbus TCP/IP) to a DCS host or an Entis+ link to an Entis system.

• Enables Modbus compliant DCS software to monitor and control the tank farm operation.

10 Endress+Hauser

Tankvision Getting Started

3.2

The Tankvision User Interface

Tankvision provides an intuitive user interface allowing the user to quickly navigate through the system. The following sections illustrate various parts of the Tankvision user interface and their usage.

The Home Page

1 2

3 4

Endress+Hauser

6 5

Pos.

1

2

3

4

5

6

Field

System Header

Navigation Tree

Main Header

Metadata Header

Main View

Alarm and Event

Panel

Description

Displays the Customer Logo or Graphic.

Contains header bars corresponding to different functional objects or groups in the system.

Refer to "Navigation Tree - detailed description" (→ ä 12) for details.

Displays the following information:

• The site name, tank name, Tankvision tag name or product name - depending on what is displayed in the Main View below the header

• The system date and time

The main header is displayed with a background color depending on the access rights of the user logged into the system:

• Grey: the user does not have configuration rights and can only view non-real time data.

• Orange: the user has configuration rights and can view real time data.

Displays the following information:

• The user name and the user type

• The language options link

• The help link

• The logout option

Displays the screens that the user has selected to configure the settings and view the operational information.

Refer to "Main View Section- Colors in Edit Data" (→ ä 12) for details.

The Alarm and Event Panel displays the real time information about alarms and events.

Refer to "Alarm and Event Panel Section- Description" (→ ä 13) for details.

11

Getting Started Tankvision

Navigation Tree - Detailed Description

The Navigation Tree is shown on the left side of the screen. Typically, the Navigation Tree allows the user to navigate down to the tanks. The image of the expanded Navigation Tree is as follows:

1

2

3

4

12

2

3

4

Pos.

1

Field

Header

Collapsed Arrow

Expanded Arrow

Node

Description

The user can click on the text or the arrow of the Header to expand or collapse the branch.

The Header name shows a number, which is dynamically appended. The number states the following:

• Tanks: The number of tanks in the NXA820

• Products: The number of products defined in the system

• Customized Groups: The number of tank groups defined in the system

• Transfers: The number of product transfer stages (Waiting, In Progress,

Finished, and Aborted) defined in the system

• Users: The number of users defined in the system

The text will appear in bold and black when the header is in the expanded form.

This type of arrow is displayed when the Header is in the collapsed position.

Click on the collapsed arrow to expand the Header.

This type of arrow is displayed when the Header is in the expanded position.

Click on the expanded arrow to collapse the Header.

The user can click on the Node to view the operational information on the Main

View section. If a Node is selected, it will appear in red color.

The number of tanks in the group is appended to the Node name.

Main View Section - Colors in the Edit Data Area

The system displays different colors in the Edit Data area, based on the access rights of the user:

1. If the user has access rights, then the edit data area has a light grey and light yellow background on alternate rows. The Submit button to save the settings is enabled.

NXA82x_Tank-Capacity-Table-Summary

Endress+Hauser

Tankvision Getting Started

2. If the user does not have access rights, then the edit data area has a light grey and dark grey background on alternate rows. The Submit button to save the settings is disabled.

NXA82x_Tank-Capacity-Table-Summary_Inactive

Alarm and Event Panel - Description

The Alarm and Event Panel displays the alarm and event information, which is dynamically generated by the system.

Tab

Alarm

Events

Alarm & Events

Description

Displays details of the alarms generated by the system.

Displays details of the events generated by the system.

Displays details of the alarms and events generated by the system.

Endress+Hauser 13

Getting Started Tankvision

3.3

Logging into the Tankvision system

To integrate a Tankvision unit (i.e. a Tank Scanner NXA820, Data Concentrator NXA821 or

Host Link NXA822) into the network, proceed as follows:

1.

Connect a laptop to the service port of the Tankvision unit. Make sure that the laptop is configured to get a dynamic IP addresses from a DHCP server.

E

L-

L+

RESET

Fuse

2 A T

RESET

MODBUS

W &M

Alarm Relay

L00-NXA82xxx-04-00-00-yy-025

2.

3.

Open the internet browser and enter the following URL: http://192.168.1.1

The Tankvision login screen appears. You are logged in as Operator

1)

.

Login as Supervisor.

Click on Login in the Meta header, the following screen opens:

NXA82x_Login-Screen

Field

User ID

Password

Description

Enter the appropriate user login name

1) sensitive.

. The user login name is alphanumeric and case

Enter the appropriate password.

1)

The user password is alphanumeric and case sensitive. It consists of 3 to 8 characters.

1) The user ID ( = User Login Name) and password are defined by the system administrator when adding a user to the system.

1) Description of Functions: Operators do not have the right to change settings. Supervisors are permitted to change settings.

14 Endress+Hauser

Tankvision

Enter ...

• ... "Super" into User ID.

• ... "Super" into Password.

• Click the Login button.

Tankvision displays the Home Page as follows:

Getting Started

Endress+Hauser

NXA82x_Home-Screen

3.4

Common settings - Tankvision system

stand alone / subscription store

Network configuration subscription store settings all other units units customer additional settings environment settings

Products

Users and users rights global configuration store device specific settings

L00-NXA82xxx-16-00-00-en-001

15

Getting Started

3.4.1

Network settings

You are logged in as "Supervisor".

1.

In the navigation tree, click the System Header. It expands as follows:

Tankvision

2.

Click Global Settings. Tankvision displays the screen as follows:

NXA82x_Menu_System

16

NXA82x_System-Screen

3.

4.

Enter the appropriate information in the relevant fields.

NXA82x_Network-Settings

Endress+Hauser

Tankvision Getting Started

Observe the following when entering information into the fields:

• Parameters marked by an asterisk are mandatory.

• The required values of the parameters depend on your local network configuration. For more information please contact your local network administrator.

• Detailed information on the individual fields, → ä 128.

5.

Click the Submit button to proceed. The system displays a confirmation box as follows:

6.

7.

8.

Click the OK button to proceed, or click the Cancel button to exit.

After saving the settings, Tankvision displays a confirmation message.

Disconnect the laptop and connect the Tankvision unit to the network using the System

LAN port. The Tankvision unit can now be operated from a computer within the LAN.

Endress+Hauser 17

Getting Started Tankvision

3.4.2

Network Node Detection

The Network Node Detection helps to detect and connect to all devices in the same network.

This is a precondition for a global/local scenario (e.g.to use a Data Concentrator NXA821 as a Global Store or for the usage of Subscription Stores).

To do so, proceed as follows:

1.

Login to the Tankvision unit as "Supervisor" and navigate to the Global Settings screen

as described in "Network settings", → ä 16.

2.

18

NXA82x_Network-Settings_Network-Node-Detection

Field

Scan Method

Description

Select the appropriate Scan Method from this field. Choose between scanning for a single

IP address (Scan Address) and scanning a range of IP addresses (Scan Address Range).

Enter the appropriate scan timeout (in milliseconds) in the text box.

Timeout in

Milliseconds

Enter Address Enter the known IP address of a device in the network into the text boxes.

This field is only available when Scan Address was selected for Scan Method.

Enter Address Range Enter a range of IP addresses, that are in the same network as the current device, into the text boxes.

This filed is only available when Scan Address Range was selected for Scan Method.

Message

Detected Units

Connected Units

Distrubute

Connected Units

Displays a message after the scan, e.g. how many devices were detected.

Lists all the devices that were detected during a scann.

Lists all devices that are already connected to the current device.

Select the check box to distribute the selected Detected Units to all connected units when clicking Save Connected Units.

Clear the check box to save the selected Detected Units only to the current device when clicking Save Connected Units.

3.

Enter the appropriate information in the relevant fields.

Endress+Hauser

Tankvision Getting Started

4.

5.

Click Perform Scan to start the Network Node Detection.

During the scan a progress bar is displayed. The rest of the screen is locked while the progress bar is displayed.

Click on the detected units (multiple selection by holding the Ctrl key while clicking) to select the detected units that are to be saved. Click Save Connected Units to save the selected units (and the current device).

Click Clear Detected Units to clear the Detected Units.

If a device in the network is removed or replaced, repeat the Network Node Detection to update the connected devices.

3.4.3

Monitoring Configuration

Configure the interval and timeout for monitoring the other devices in the network as well as the network quality.

To do so, proceed as follows:

1.

Login to the Tankvision unit as "Supervisor" and navigate to the Global Settings screen

as described in "Network settings", → ä 16. Click on Customer Settings.

2.

Endress+Hauser

NXA82x_Network-Settings_Monitoring-Configuration

Column

Unit Type

Monitoring interval in Milliseconds

Timeout in

Milliseconds

Description

Displays the device type (Tank Scanner NXA820, Data Concentrator NXA821, Host Link

NXA822).

Enter the appropriate interval, in which the current device checks if the other devices in the network are available, in the text box.

Enter the appropriate timeout for the availability check of the other devices in the network in the text box.

Field

QNet-Timeout & -

Retry Setings

Description

Select the appropriate network quality. The names of the settings are self-explanatory.

3.

4.

Enter the appropriate information in the relevant fields.

Click the Save Monitoring Configuration button.

3.4.4

Time Server Settings

The availability of the Time Server Settings depends on the Configuration Store Type

selected in Define Configuration Store Details (→ ä 21).

Synchronize the time of the device with a time server in the network.

To do so, proceed as follows:

19

Getting Started Tankvision

1.

Login to the Tankvision unit as "Supervisor" and navigate to the Global Settings screen

as described in "Network settings", → ä 16. Click on Customer Settings.

2.

NXA82x_Network-Settings_Time-Server-Settings

Field

Synchronize time against time server

Server IP-Address

Description

Select the check box to synchronize the system time of the current device with a time server in the network.

Clear the check box to use the system time of the current device.

Only available if Subscription Store is selected as the Configuration Store Type in

Define Configuration Store Details (→ ä 21).

Not available if Use Local Configuration Store is selected as the Configuration Store

Type, because this setting always uses the system time of the current device.

If Use Global Configuration Store is selected as the Configuration Store Type, the IP address of the configured Subscription Store is automatically used as time server.

Enter the appropriate IP address of a time server. The IP address has to be available in the network of the current device.

Entering the IP address "127.127.1.0" (default) synchronizes with the internal real-time clock of the current device.

If an invalid IP address is entered and Submit button is clicked, the field returns to the last valid IP address.

This field is only available if the Synchronize time against time server check box is available and selected.

NOTE! Do not use other Tankvision devices as time servers.

3.

4.

Enter the appropriate information in the relevant fields.

Click the Submit button.

The time of synchronization depends, amongst other things, on the network quality.

20 Endress+Hauser

Tankvision Getting Started

3.4.5

Subscription Store definition

In a typical Tankvision system, most configuration settings are common for all Tankvision units within the network. Therefore, the time required for the configuration of the system can be minimized by defining one of the units to be a Subscription Store. The configuration settings are only performed on this Subscription Store. These settings are then distributed to the other units within the network.

For each Tankvision unit (i.e. Tank Scanner NXA820, Data Concentrator NXA821 or Host

Link NXA822) within the network it is necessary to define if it is a Subscription Store or if it receives its configuration from a Subscription Store.

To do so, proceed as follows:

1.

Login to the Tankvision unit as "Supervisor" and navigate to the Global Settings screen

as described in "Network settings", → ä 16. Click on Customer Settings.

2.

Click follows: on

NXA82x_Define-Configuration-Store-Details

3.

For the Subscription Store:

• In Configuration Store Type select the option Subscription Store (Default)

For the other units

• In Configuration Store Type select the option Use Global Configuration Store

• In Subscription Store select the Subscription Store to which this unit is to be linked

• In Allow Local Configuration Change define whether local configuration changes of this unit are allowed in case the Subscription Store is not available.

4.

5.

Click the Submit button to proceed, or click the Refresh button to reset the screen.

After saving the settings, Tankvision displays a confirmation message.

With the (recommended) use of global configuration store the following information is transferred to the subscription units:

• Customer settings like site information (without customer specific logo), unit, email server and day and time settings (configurations of languages and printer agent must be done for every single device)

• Environment settings

• Products

• Users incl. user access rights

Global settings could be changed later on, also after assigning other units. It is highly recommended to use a NXA820 as subscription store.

Endress+Hauser 21

Getting Started Tankvision

3.4.6

Further common steps (stand alone or subscription store)

Login to the Tank Scanner NXA820 as "Supervisor" and perform the following configurations:

1. Customer Settings and Environment Settings a. In the navigation tree, click the System header.

b. Click Global Settings (below the System header).

c. In the main screen click the Customer Settings header and configure the

parameters (→ ä 199).

d. In the main screen, click the Environment Settings header and configure the

parameters (→ ä 199).

2. Product Configuration a. In the navigation tree, click the Products header.

b. Click the Add button to add a new product.

c. Click the individual headers of the Product menu (General Details, Volume

Correction Factor, ...) and define the product properties (→ ä 91).

3. Users and user access rights a. In the navigation tree, click the Users header.

b. Click on Group rights tab and define the rights of the different users.

c. Click on User view and create the required users.

22 Endress+Hauser

Tankvision Getting Started

3.4.7

Tank Scanner NXA820 specific settings

Login to the Tank Scanner NXA820 as "Supervisor" and perform the following configurations:

1. Field Scan Configuration a. In the navigation tree, click the System header.

b. Click Global Settings (below the System header).

c. In the main screen, click the Field Scan header.

d. Click the individual headers of the Field Scan menu and configure the parameters

2)

.

For a description of the parameters refer to

– Chap. 12.5 (Modbus)

– Chap. 12.6 (V1)

– Chap. 12.7 (WM550)

2. Tank Configuration a. In the navigation tree, click the Tanks header.

b. In the main screen, select the tank you are going to configure and click the Modify button.

c. Click the individual headers of the tanks menu (General Details, Capacity Details,

...) and configure the parameters (→ ä 35).

3. Product-tank assignment a. In the navigation tree, click the Tanks header.

b. In the list below the Tanks header select a tank.

c. In the main screen click the Assignment Product tab (if necessary use the << or >> button to find the Assign Product tab.

d. Select the product from the drop-down list.

e. Click Submit to save the settings.

For details about tank-product assignment refer to Chap. 8.7.

4. Additional Settings

Depending on your requirements, you can perform numerous further settings.

5. Start Field Scan a. In the navigation tree, click the System header.

b. Click Global Settings (below the System header).

c. In the main screen, click the Field Scan header.

d. Click the Start/Stop Field Scan tab and then click on Start. Field Scanning is now active.

2) The parameters can only be edited if the field scan is not currently active. If necessary, go to the Start/Stop Field Scan tab and stop the field scan.

Endress+Hauser 23

Getting Started Tankvision

3.4.8

Data Concentrator NXA821 specific settings

1. Associate Tank Scanner

Assign the Tank Scanner NXA820 to the Data Concentrator NXA821: a. Login to the Data Concentrator NXA821 as "Supervisor".

b. In the navigation tree, click the System header.

c. Click Global Settings (below the System header).

d. In the main screen, click the header Tank Scanner Unit And Tank Assignment.

e. Select all Tank Scanner units you want to assign to the Data Concentrator from the

Available Units list and move them to the Selected Units list using the arrow buttons. All units in the Selected Units list will be assigned to the Data

Concentrator.

f. Click the Submit button to save the settings.

2. Additional Settings (like groups)

Depending on your requirements, you can perform numerous further settings.

3.4.9

Host Link NXA822 specific settings

The Host Link NXA822 provides an interface for a host system to access inventory data from the NXA820 unit. To configure the Host Link settings, proceed as follows:

1. Login to the Host Link NXA822 as "Supervisor".

2. In the navigation tree, click the System header.

3. Click Global Settings (below the System header).

4. In the main screen, click the Field Scan header.

It contains the following sub-headers which are used to configure the Host Link settings and to start the Host Link:

– Host Link Configuration

– Modbus TCP Configuration (if the Modbus TCP protocol has been selected).

– Modbus Serial (if the Modbus Serial protocol has been selected).

– Entis+ (if the Entis+ serial protocol has been selected)

– Start/Stop Host Link

24 Endress+Hauser

Tankvision Getting Started

3.4.10 Configuration of W+M systems

Description of the sealing process

Locking mechanisms in Tankvision:

Connected PCs are registered in the system by assigning the MAC address. Once the system has been locked, only these PCs are accepted and can display calibrated data.

When the W+M switch is flipped, a checksum is calculated and set.

This calculation is repeated every 8 hours. If this checksum deviates from that at the time of sealing, changes have been made to the system. It is no longer possible to modify W+M parameters, such as tank tables, units and print templates, once the W+M switch has been flipped.

Recommended procedure:

It is recommended to start calibrating the tank gauging system from the field devices via possible protocol converters and finish the process with the Tankvision inventory management system. When calibrating the Tankvision Tank Scanner or Data Concentrator, it is recommended to start with the unit used as the Global Configuration Store since the engineering units are configured centrally here. These units would then not have to be

checked separately in the boxes assigned (see "Units", → ä 26).

Endress+Hauser 25

Getting Started Tankvision

Initial calibration and system modifications

Initial calibration and changes to the Tankvision Tank Scanner NXA820

Units

The units do not have to be configured if Use Global Configuration Store (→ ä 21) is

selected. The units can be checked under System → Tank Scanner Unit → Customer

Settings → Units.

This view allows the user to choose between the unit schemes.

Selecting the Unit

The exact settings of the unit scheme selected can be checked under Advanced.

26

NXA82x_Units

Checking the Units

Observe the following information!

• An apostrophe may not be chosen as the thousand separator for W&M applications.

• If the Tankvision device retrieves the basic settings from another Tankvision device (Global

Configuration Store), the units of this Tankvision device do not have to be checked. The name of the box (Subscription Store) that provides the basic settings can be found under

System → Global Settings → Customer Settings → Define Configuration Store Details

(Fig. Configuration Store Details).

Configuration Store Details

NXA82x_Define-Configuration-Store-Details

Endress+Hauser

Tankvision Getting Started

Field device assignment

The field device assignment must be checked under System → Tank Scanner Unit → Field

Scan → Manage Field Scan Configuration-Modbus EIA485.

The following parameters have to be checked for Modbus EIA485:

• Baud rate

• Parity

• Gauge slave address: assignment to the tank ID / tank name

• Gauge type: assignment to the tank ID / tank name

• Modbus register map: assignment to the field device type (gauge type)

Field Scan Configuration - Modbus

Endress+Hauser 27

Getting Started

The following parameters have to be checked for the V1 protocol:

• Gauge slave address (DEC) assignment to the tank ID / tank name

• Gauge type assignment to the tank ID / tank name

• V1 map file assignment to the gauge type

Tankvision

Field Scan Configuration - V1 Protocol

The following parameters have to be checked for the WM550 protocol:

• Baud rate

• Loop current

• Gauge slave address assignment to the tank ID / tank name

• Gauge type assignment to the tank ID / tank name

• WM550 map file assignment to the field device type (gauge type)

28 Endress+Hauser

Tankvision

Field Scan Configuration - WM550 Protocol

Getting Started

Endress+Hauser 29

Getting Started Tankvision

Tank table

The tank capacity details have to be loaded to check the tank table (Tanks → Select the tank under Select - select and confirm with Modify (see Fig. "Tank Selection") → Select Capacity

Details (see Fig. "Tank Capacity Table Summary")).

Tank Selection

NXA82x_Capacity-Details

Tank Capacity Table Summary

Steps for checking the tank table:

• Check that the information in the Tank Capacity Table Summary is correct for the selected tank.

• Check whether the TCT is suitable for the relevant tank.

Clicking Show TCT file opens a browser window that shows the TCT in a tabular form

(with the units in the configured format). Print by clicking Print TCT.

To store the TCT file on a PC, click the Get TCT file link. The system will perform an export of the TCT in XML form as a compressed file (.gz). All units in the file are SI units

(independent from the configured format).

30 Endress+Hauser

Tankvision Getting Started

Endress+Hauser

Table in XML Format

Tankvision_TCT

31

Getting Started

PC assignment

Tankvision

Tankvision Tank Scanner - PC Assignment

Every PC to be connected to the sealed system has to be registered. The PCs are registered under System → Global Settings → W&M Seal → Access Configuration.

The registered devices are listed with their MAC address in the column on the left.

The MAC address of the PC currently used is displayed in the column on the right.

Each PC has to be registered individually on every Tankvision box. If no PC is registered in the system, an error message is shown on the display of the Tankvision box once the W+M switch has been flipped.

NXA

0.0.0.0

172.0.0.1

02/12/2009

02:51:54 PM

NXA820_A30016011

F317:

Access Configuration Er

L00-NXA820xx-07-00-00-xx-001

Error Message - No PC Registered in the System

During calibration acceptance, the list must be checked to ensure it only contains the MAC addresses of the Tankvision boxes and the PCs that should access the system. The PCs can be checked, for example, by loading the page above from every PC that should have access to the system and then comparing the MAC addresses (Registered Systems against Current

MAC Address). The MAC addresses of the Tankvision box are provided on the nameplate.

32 Endress+Hauser

Tankvision

Endress+Hauser

Getting Started

Sealing tank data

The tank data are sealed individually for every tank. The W+M values are selected under :

Tanks → Select the Tank (Select + Modify) → Put Tank into Calibrated Status.

For more details, → ä 54.

NXA82x_Put-Tank-into-Calibrated-status

Sealing Tank Data

If the W+M switch is flipped, tanks can be removed from the calibrated status. This changes the calibration checksum. Removing a tank from the sealed system is equivalent to a system modification and must be accepted by an official from the

Standards Authority.

Locking

The unit is locked by flipping the W+M switch on the Tankvision Tank Scanner NXA820.

E

L+

MODBUS

W &M

NXA Status

Relay

A

L00-NXA82xxx-04-00-00-xx-002

A Tankvision W+M Switch

Flipping the switch means that the settings checked under "Sealing tank data" (→ ä 33) are

fixed and can no longer be modified, and that the values specified under Sealing Tank Data are displayed as calibrated values by the computers specified under PC Assignment. A master checksum is calculated approx. 2 minutes after the W+M switch is flipped. This master checksum can be called up under System → Tank Scanner Unit → W&M Seal. After approximately 2 more minutes, the system performs the first check calculation. The subsequent calculations are then performed every 8 hours.

The following information is displayed:

• Date and time the page was loaded

• W&M switch status

• W&M CRC at sealing time

• Last calculated W&M CRC

• Last calculated CRC’s time stamp

Tankvision W&M Seal

33

Getting Started Tankvision

A modified checksum indicates that changes have been made to the system. The checksum must be documented (e.g. by printing out the screenshot, see Figure "Tankvision W&M Seal") and recorded in the acceptance report (e.g. by attaching the printout).

The checksum can be recalculated by switching the Field Scan off and then on again.

Checking the W&M display

The following steps must be taken to check the weights and measures display:

• The settings listed under "Sealing tank data" (→ ä 33) can no longer be modified.

• A WM in front of the values for the Product Level, Product Temperature and Total

Observed Volume indicates that the values are calibrated.

• The level and temperature information has to match that of the field devices.

Checking the printouts

All printouts from connected printers that cannot be officially verified must bear the annotation "Measured values not calibrated" and no measured values may appear as calibrated.

Initial calibration and changes to the Tankvision Data Concentrator NXA821

Tank Scanner assignment

The assignment between the Tank Scanner units and the Data Concentrator must be checked under System → Data Concentrator Unit → Tank Scanner Unit and Tank

Assignment.

Tankvision Data Concentrator - Tank Scanner Assignment

PC assignment

The locking procedure is the same as for the tank scanner (see "Locking", → ä 33).

Stamp points for Tankvision Tank Scanner NXA820 and Data Concentrator NXA821

The stamp points are listed under Point 6 in type approval 4.454/08.10.

34 Endress+Hauser

Tankvision

Endress+Hauser

The Tankvision Operating Screens

4 The Tankvision Operating Screens

Operating Screen

Tanks - Tank Details Tab

General Details

Capacity Details

Shell Details

Floating Roof

Flow Calculation

Water Content

Hybrid Tank Measurement System

Inventory Calculation

Put Tank into Calibrated Status

HART command

Tanks - Alarm Settings Tab

Measured Data Alarm Configuration

Calculated Data Alarm Configuration

Tanks - Gauge Commands Tab

Tank Screen

The "General Details" tab

The "Spot Temperature" tab

The "Manual Data" tab

The "Dipped Data" tab

The "Gauge Commands" tab

The "Real Time Trend" tab

The "Product Transfer" tab

The "Tank Status" tab

The "Assign Product" tab

The "Product Transfer Report" tab

The "Tank Calculator" tab

Menu Products

Adding, Modifying and Deleting Products

General

Volume Correction Factor (VCF)

Reference Density Calculation (RDC)

Sediment & Water

Mass & Weight

Vapor Calculation

Advanced (Weight & Measure)

View Product Tank Groups

Menu Customized Groups

Menu Transfers

→ ä 84

→ ä 87

→ ä 88

→ ä 88

→ ä 91

→ ä 91

→ ä 93

→ ä 94

→ ä 63

→ ä 64

→ ä 66

→ ä 67

→ ä 68

→ ä 69

→ ä 73

→ ä 75

→ ä 95

→ ä 96

→ ä 98

→ ä 99

→ ä 100

→ ä 101

→ ä 105

→ ä 114

→ ä 52

→ ä 53

→ ä 54

→ ä 55

→ ä 56

→ ä 57

→ ä 59

→ ä 61

Page

→ ä 37

→ ä 38

→ ä 40

→ ä 45

→ ä 47

→ ä 49

→ ä 51

x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

NXA820 NXA821 NXA822 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

35

The Tankvision Operating Screens

Operating Screen

Menu System

Customer Settings

Network Setting

Environment Settings

Trend Global Settings

Field Scan - Modbus EIA485

Configure Field Scan - Sakura V1

Configure Field Scan - Whessoe WM550

W&M Seal

Data Archival

Tank Scanner Unit and Tank Assignment

Host Link

Downloads

Operator Workstation Settings

System Diagnostics

Uploads

Tankvision Outputs

Menu Reports

Select NXA820 Configuration Details

Select Product Transfer Details

Event Report

Alarm Report

Select Tanks For Tank Report

Select Tanks For Tank Detail Report

Select Tank Groups For Report

Select Inventory Report

Menu Users

KPI Dashboards

Tankvision x x x x x x x x x x x x x x x x x x x x x x x x

NXA820 NXA821 NXA822 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

→ ä 189

→ ä 197

→ ä 198

→ ä 199

→ ä 199

→ ä 200

→ ä 200

→ ä 201

→ ä 201

→ ä 202

→ ä 202

→ ä 203

→ ä 211

→ ä 146

→ ä 151

→ ä 153

→ ä 160

→ ä 161

→ ä 181

→ ä 185

→ ä 187

Page

→ ä 116

→ ä 117

→ ä 128

→ ä 134

→ ä 135

→ ä 136

→ ä 141

36 Endress+Hauser

Tankvision The "Tanks" menu - Tank Details

5 The "Tanks" menu - Tank Details

The working of the entire Tankvision system depends on the tanks and their contents. The

Tankvision system acquires measured data from the gauges, processes these data using

Tank Inventory calculations and then presents the data on the Tankvision interface for the user to view or access. Some of the inventory data such as volume and mass depend on the tank configuration and the product assigned to the tank.

To configure a tank

1.

On the Navigation Tree, click the Tanks Header. (The number of tanks configured is displayed in brackets next to the Header’s name). The Manage Tanks screen appears:

Endress+Hauser

2.

3.

Select the appropriate tank by clicking on the selection box in front of the tank.

Click the Modify button to modify the tank details. Tankvision displays the Tank

Details screen as follows:

With the Manage Tanks button, you can step back to the Manage Tanks screen.

37

The "Tanks" menu - Tank Details Tankvision

5.1

General Details

The General Details screen allows the user to view and modify the general details of the tank according to the requirements.

To configure the general details of the tank

1.

38

NXA82x_Tank-Details_General-Details

Field

Tank ID

Tank Name

Tank Location

Tank Level Type

Description

Each tank in the system has a unique numerical identifier ranging from 1 to 15. This ID is used in the system to refer to the tank to display the tank data, perform product transfer, generate reports, etc. This field is not editable.

Enter the name of the tank. Each tank in the Tankvision system has a unique name for reference, which should not exceed 16 characters in length. The data type for this field is alphanumeric and can contain the special characters "-" and "_" (hyphen and underscore).

Enter the location of the Tank. This field is used to identify the tank and enables the creation of a tank group based on the physical location of the tank in a tank farm.

The data type for this field is alphanumeric and can contain all special characters.

Select the appropriate settings in which way the measured value is transmitted from gauge. Innage or Ullage.

Tank Type

Gauge Model

Gauge Reference

Height

Pressure Transmitter

Type

Position of Lowest

Temperature Sensor

Temperature Status

When Level is too

Low

Change Picture

Select the appropriate type of tank from the drop down list.

This field indicates whether the tank has a floating roof or not. This enables the

Tankvision system to decide whether to perform the floating roof adjustment during tank calculation.

Enter the appropriate gauge model name or number for the tank.

The data type for this field is alphanumeric and can contain all special characters.

Enter the appropriate height of the gauge or tank top. The field is used to convert the product ullage level to the innage level. The data type for this field is numeric.

Enter the appropriate pressure type option. This field specifies, whether the measured pressure is absolute or relative if the pressure is measured using a pressure gauge.

Enter the value of the position of the lowest temperature sensor.

This field indicates the level of the lowest temperature sensor. If the product level falls below the position of lowest temperature sensor, then the temperature measured by this sensor can no more be considered as product temperature in the tank calculations.

Select the appropriate temperature status from the drop down list.

This field indicates the temperature status when the product level drops below the position of the lowest temperature sensor. This enables the system to change the value of the temperature status to an existing value in the drop down list.

Click the Change Picture link to change the picture of the tank.

Refer to section "Change Tank Picture" (→ ä 39) for more details.

2.

3.

Enter the appropriate information in the relevant fields.

Click the Submit button to save the tank general details.

Endress+Hauser

Tankvision The "Tanks" menu - Tank Details

4.

After saving the settings, Tankvision displays a confirmation message.

An event is generated after configuring the tank general details. The event details can be viewed in the Event or Alarm & Event overview.

5.1.1

Change Tank Picture

To change the tank picture

1.

Click the Change picture link on the General Details screen. Tankvision displays the screen as follows:

NXA82x_Tank-Details_Change-Tank-Picture

2.

3.

4.

Click the appropriate option to select the picture.

Click the Submit button to save the tank image or click the Cancel button to exit.

Tankvision returns to the General Details screen.

Endress+Hauser 39

The "Tanks" menu - Tank Details Tankvision

5.2

Capacity Details

Capacity Details are used to calculate the product volume from the product level. The most common industry method to measure the product volume is to use a Tank Capacity Table

(TCT).

A TCT has a number of data points for each level in the tank and it gives the product volume corresponding to these levels. The Capacity Details screen allows you to view and modify the details of the tank in terms of the tank capacity table, total volume, minimum volume of the product that can be pumped out of the tank, etc.

To configure tank capacity details

1.

40

NXA82x_Capacity-Details

Field

Sump & Pipeline Volume

Description

Select TCT file to Download Enter the appropriate path to download the TCT file, or click the Browse button to search for an appropriate file location. The system reads the product level and uses the corresponding volume from the TCT as the product volume for further calculations. Read more about the TCT file contents below.

Enter the value of the sump and pipeline volume. This field indicates the volume of the product contained in the sump and pipeline. The data type for this field is numeric.

Maximum Tank Capacity

Volume Calculation

Method

Sub Table Present

Indicates the maximum volume which can be filled into a tank.

Value: Raw

Product Density for FRA

Heel Volume

TCT Level Type

Indicates wether a sub strapping table is present in the downloaded Tank Capacity

Table.

P_Density_FRA, if present is the density used to calculate the displaced volume.

"Waste" volume, located on the tank bottom, it’ll be substracted from the actual volume.

Defines the level type of entered straps in the Tank Capacity Table.

Values: Innage, Ullage

Minimum pumpable volume

Number of Straps

Water Table Present

Volumetric Floating Roof

Correction

Get TCT file

Static Pressure Table

Present

View TCT file

Indicates the minimum pumpable volume of the attached pump on the tank.

While configuring a product transfer this should be considered as minimum batch size.

Value shows the number of straps read from the Tank Capacity Table.

Indicates whether a water table is present in the downloaded Tank Capacity Table.

V_FRC, if present it is used to correct the volume.

Link to download a Tank Capacity Table.

Indicates whether a table for static pressure correction is present in the downloaded Tank Capacity Table.

Link to view a Tank Capacity Table.

2.

Click the Browse button to search the TCT file location.

Endress+Hauser

Tankvision The "Tanks" menu - Tank Details

3.

4.

5.

6.

Click the Download Tct Xml File button to download a TCT XML file from the system.

Enter the sump and pipeline volume in the Sump & Pipeline Volume field.

Click the Submit button to save the tank capacity details.

Tankvision displays the capacity details in the Tank Capacity Table Summary section, which is imported from the TCT file. After saving the details, Tankvision also displays a confirmation message.

An event is generated after configuring the tank capacity details. The event details can be viewed in the Event or Alarm & Event overview.

Endress+Hauser 41

The "Tanks" menu - Tank Details Tankvision

5.2.1

TCT XML file contents

The TCT file is a XML file, which provides the following information about the tank.

XML Tag

TCT_Date

TCT_CalDate

Definition

TCT Date

TCT Calibrated Date

Units

Level

Volume

Weight

P_Density_FRA

FRA_TCT

P_Density_FRA

V_FRC

Heel_Volume

Max_Tank_Capacity

Total_Tank_Volume

Min_Pump_Volume

P_TCT

CNT

P_Strap

P_Level

P_Volume

Sub_TCT

Min_Sub_TCT_Level

P_S_TCT

CNT

P_S_Strap

P_S_Level

P_S_Volume

WATER_TCT

Water

CNT

W_Strap

W_Level

W_Volume

VSP_TABLE

VSP_TABLE

CNT

P_Strap

P_Level

VSP_Vol

Units

- Level Unit

- Volume Unit

- Weight Unit

- Density Unit

Floating Roof Details

- Used Liquid Density

- Volumetric FR Correction

Heel Volume

Max Tank Capacity

Total Tank Volume

Minimum Pumpable Volume

Main TCT Table

- Number of TCT straps

- - Each Strap

- - - Level

- - - Volume

Sub TCT Present

Minimum Sub TCT level

Sub TCT Table

- Number of Sub TCT Straps

- - Each Strap

- - - Level

- - - Volume

Water Table Present

Water Table

- Number of Water TCT Straps

- - Each Strap

- - - Level

- - - Volume

Static Pressure Table Present

Static Pressure Table

- Number of VSP straps

- - Each Strap

- - - Level

- - - Volume

42 Endress+Hauser

Tankvision

Endress+Hauser

The "Tanks" menu - Tank Details

Sample TCT file

<?xml version =“1.0"?>

<Tankvision CRC =“12345“>

<Level_Type>Innage</Level_Type>

<Units>

<Level>mm</Level>

<Volume>m3</Volume>

<P_Density_FRA_Unit>kg/m3</P_Density_FRA_Unit>

</Units>

<FRA_TCT>

<P_Density_FRA>1500</P_Density_FRA>

<V_FRC>1</V_FRC>

</FRA_TCT>

<Heel_Volume>50</Heel_Volume>

<Total_Tank_Volume>62369</Total_Tank_Volume>

<Max_Tank_Capacity>61745</Max_Tank_Capacity>

<Min_Pump_Volume>624</Min_Pump_Volume>

<Volume_Method>RAW</Volume_Method>

<P_TCT CNT=“13">

<P_Strap><P_Level>0</P_Level><P_Vol>87</P_Vol></P_Strap>

<P_Strap><P_Level>50</P_Level><P_Vol>500</P_Vol></P_Strap>

<P_Strap><P_Level>100</P_Level><P_Vol>1000</P_Vol></P_Strap>

<P_Strap><P_Level>200</P_Level><P_Vol>2000</P_Vol></P_Strap>

<P_Strap><P_Level>410</P_Level><P_Vol>5771</P_Vol></P_Strap>

<P_Strap><P_Level>470</P_Level><P_Vol>6604</P_Vol></P_Strap>

<P_Strap><P_Level>1000</P_Level><P_Vol>14047</P_Vol></P_Strap>

<P_Strap><P_Level>1080</P_Level><P_Vol>25170</P_Vol></P_Strap>

<P_Strap><P_Level>2440</P_Level><P_Vol>44039</P_Vol></P_Strap>

<P_Strap><P_Level>2580</P_Level><P_Vol>45976</P_Vol></P_Strap>

<P_Strap><P_Level>4160</P_Level><P_Vol>57809</P_Vol></P_Strap>

<P_Strap><P_Level>10000</P_Level><P_Vol>80000</P_Vol></P_Strap>

<P_Strap><P_Level>20000</P_Level><P_Vol>100000</P_Vol></P_Strap>

</P_TCT>

<W_TCT CNT=“10">

<W_Strap><W_Level>-1000</W_Level><W_Vol>0</W_Vol></W_Strap>

<W_Strap><W_Level>-778</W_Level><W_Vol>222.22</W_Vol></W_Strap>

<W_Strap><W_Level>-556</W_Level><W_Vol>444.44</W_Vol></W_Strap>

<W_Strap><W_Level>-333</W_Level><W_Vol>666.66</W_Vol></W_Strap>

<W_Strap><W_Level>-111</W_Level><W_Vol>888.88</W_Vol></W_Strap>

<W_Strap><W_Level>111</W_Level><W_Vol>1111.1</W_Vol></W_Strap>

<W_Strap><W_Level>333</W_Level><W_Vol>1333.32</W_Vol></W_Strap>

<W_Strap><W_Level>555</W_Level><W_Vol>1555.54</W_Vol></W_Strap>

<W_Strap><W_Level>778</W_Level><W_Vol>1777.76</W_Vol></W_Strap>

<W_Strap><W_Level>1000</W_Level><W_Vol>1999.98</W_Vol></W_Strap>

</W_TCT>

<VSP_TABLE CNT=“23">

<P_Strap><P_Level>1000</P_Level><VSP_Vol>0</VSP_Vol></P_Strap>

<P_Strap><P_Level>1100</P_Level><VSP_Vol>0</VSP_Vol></P_Strap>

<P_Strap><P_Level>1200</P_Level><VSP_Vol>0</VSP_Vol></P_Strap>

<P_Strap><P_Level>1300</P_Level><VSP_Vol>0</VSP_Vol></P_Strap>

<P_Strap><P_Level>1400</P_Level><VSP_Vol>13</VSP_Vol></P_Strap>

<P_Strap><P_Level>1500</P_Level><VSP_Vol>14</VSP_Vol></P_Strap>

<P_Strap><P_Level>1600</P_Level><VSP_Vol>16</VSP_Vol></P_Strap>

<P_Strap><P_Level>1700</P_Level><VSP_Vol>22</VSP_Vol></P_Strap>

<P_Strap><P_Level>1800</P_Level><VSP_Vol>28</VSP_Vol></P_Strap>

<P_Strap><P_Level>1900</P_Level><VSP_Vol>34</VSP_Vol></P_Strap>

<P_Strap><P_Level>2000</P_Level><VSP_Vol>40</VSP_Vol></P_Strap>

<P_Strap><P_Level>3000</P_Level><VSP_Vol>102</VSP_Vol></P_Strap>

<P_Strap><P_Level>4000</P_Level><VSP_Vol>215</VSP_Vol></P_Strap>

<P_Strap><P_Level>5000</P_Level><VSP_Vol>360</VSP_Vol></P_Strap>

<P_Strap><P_Level>6000</P_Level><VSP_Vol>542</VSP_Vol></P_Strap>

<P_Strap><P_Level>7000</P_Level><VSP_Vol>789</VSP_Vol></P_Strap>

<P_Strap><P_Level>8000</P_Level><VSP_Vol>1073</VSP_Vol></P_Strap>

<P_Strap><P_Level>9000</P_Level><VSP_Vol>1403</VSP_Vol></P_Strap>

<P_Strap><P_Level>10000</P_Level><VSP_Vol>1802</VSP_Vol></P_Strap>

<P_Strap><P_Level>11000</P_Level><VSP_Vol>2237</VSP_Vol></P_Strap>

<P_Strap><P_Level>12000</P_Level><VSP_Vol>2728</VSP_Vol></P_Strap>

<P_Strap><P_Level>13000</P_Level><VSP_Vol>3270</VSP_Vol></P_Strap>

<P_Strap><P_Level>20000</P_Level><VSP_Vol>5000</VSP_Vol></P_Strap>

</VSP_TABLE>

</TCT>

</Tankvision>

L00-NXA82xxx-16-00-00-xx-070

43

The "Tanks" menu - Tank Details Tankvision

Observe the following information regarding the TCT file!

• The date format should be according to the configuration done. E.g. if the format is MM/

DD/YYYY the value should be like 01/21/2005 (Note the leading zeros in date and month.)

• If the FRA Calculation Configuration is to be read from the TCT XML, the user needs to configure the tank to have a Floating Roof using the Tank General Details screen and the

Floating Roof Adjustment Method in Floating Roof should be configured as "Fra In Tct".

If the user has not done these setting, system will ignore the data even if they are present in the TCT XML.

• The name of the TCT XML should not contain spaces or special characters such as #, %, @,

& etc.

• If the precision digit configuration settings are changed, the user needs to download the

TCT XML again to reflect the changes.

• The user can add normal XML comments in the TCT XML.

Example

<P_TCT CNT="2">

<P_Strap>

<P_Level>0</P_Level>

<! -- Prev value = 0 -->

<P_Vol>0.1</P_Vol>

</P_Strap>

44 Endress+Hauser

Tankvision The "Tanks" menu - Tank Details

5.3

Shell Details

The tanks are often made of iron, steel or other suitable alloys. The tank shell often undergoes dimensional changes as a result of thermal expansion. The change in dimension of the tank shell results in a change of the apparent product level, thereby introducing an error in the subsequent volume calculations. The volume therefore needs to be corrected by the Correction of the Tank Shell Deformation (CTSh) based on the tank shell details configured for a tank.

The Shell Details screen allows you to view and modify the details of the tank in terms of the tank shell thermal expansion coefficient, insulation factor, etc.

To configure tank shell details

1.

Endress+Hauser

NXA82x_Shell-Details

Field

Tank Shell Correction

Enabled

Description

Select the check box to allow the system to apply tank shell correction to the product volume.

Clear the check box to prevent the system from applying tank shell correction to the product volume.

Tank Shell

Calibration

Temperature

Linear Thermal

Expansion

Coefficient

Enter the temperature at which the tank shell was calibrated.

The system uses the tank shell calibration temperature from this field to calculate the tank shell correction factor. The data type for this field is numeric.

Enter the linear thermal expansion coefficient of the tank shell material.

The system uses the linear thermal expansion coefficient value from this field to calculate the tank shell correction factor. The value of the linear thermal expansion coefficient for the tank shell material should be greater than zero. The data type for this field is numeric.

Area Thermal

Expansion

Coefficient

Enter the appropriate value for the Area thermal expansion coefficient of the tank shell material.

The system uses the Area thermal expansion coefficient value from this field to calculate the tank shell correction factor. The value of the area thermal expansion coefficient of the tank shell material should be greater than zero. The data type for this field is numeric.

Select the appropriate temperature status from the drop down list. This field indicates the temperature status propagation, when the automatic temperature is not available.

Temperature Status

Propagation

Tank Shell Insulation

Type

Select the appropriate Tank shell insulation type from the drop down list. The system uses the Tank shell insulation type value from this field to calculate the tank shell correction factor.

The tank shell insulation types are:

Not Insulated (according to API) - If this type is selected, the Tank Shell Insulation

Factor will be +0.8750. This value is not editable.

Insulated - If this type is selected, the Tank Shell Insulation Factor will be +1.0000. This value is not editable.

Custom - If this type is selected, the Tank Shell Insulation Factor field is editable, and an appropriate value can be entered to calculate the tank shell temperature.

Tank Shell Insulation

Factor

Enter the appropriate tank shell insulation factor. This field is enabled when the user selects the Custom option in the Tank Shell Insulation Type field. The system uses the tank shell insulation factor to calculate the tank shell temperature. The value for the tank shell insulation factor is between zero and one. The data type for this field is numeric.

Vessel Radius Enter the vessel radius of the tank. The value of the vessel radius should be greater than

0.

The system uses the vessel radius for the tank calculations. The data type for this field is numeric.

45

The "Tanks" menu - Tank Details Tankvision

2.

Enter the appropriate information in the relevant fields.

3.

4.

Click the Submit button to save the tanks shell details.

After saving the settings, Tankvision displays a confirmation message.

An event is generated after configuring tank shell details. The event details can be viewed in the Event or Alarm & Event overview.

Error Messages

1. "Invalid Calibration Temperature"

This message appears if the tank shell calibration temperature entered by the user is not a valid real number.

2. "Invalid Linear Thermal Coefficient"

This message appears if the value of the linear thermal coefficient, entered by user is not a valid real number.

3. "Linear Thermal Coefficient should be smaller than ... 10E-7/°C."

This message appears if the value of the linear thermal coefficient entered by user is greater than the internally defined limit.

4. "Invalid Area Thermal Coefficient"

This message appears if the value of the Area Thermal Coefficient entered by user is not a valid real number.

5. "Area Thermal Coefficient should be smaller than ... 10E-14/°C."

This message appears if the value of the Area thermal coefficient for entered by user is greater than the Maximum Thermal Coefficient.

6. "Fill Out All Mandatory Entries"

This message appears if the user has not entered the value for Linear or Area thermal coefficient.

7. "Invalid Insulation Factor, should be between 0 and 1"

This message appears when the value of the tank shell insulation factor entered by user is not a valid real number or is less than zero or greater than one.

46 Endress+Hauser

Tankvision The "Tanks" menu - Tank Details

5.4

Floating Roof

A tank can often have a floating roof. A floating roof is called so because it floats on the product stored in the tank. The roof moves up or down along with product level. Since the roof is floating on the tank, it displaces some amount of product depending on the weight of the roof and the density of the product. This displacement in product level results in a different apparent level, introducing an error into the volume calculations. The product volume therefore needs to be corrected.

A floating roof often has supporting legs. The roof can be rested on these legs when the level is too low or the tank is empty. This allows maintenance staff to enter below the roof for carrying on tank maintenance. Based on the product level, the floating roof can be landed on the legs or floating on the product. However, in a certain range of product level, the floating roof can be partially landed. This zone is called 'critical zone'. In the Tankvision system there can be two critical zones related to the position of the floating roof legs.

The fields in the Floating Roof screen are enabled if the Tank Type in the General Details screen is selected as Tank with external floating roof, without stilling well, Tank with external floating roof, with stilling well, Tank with internal floating roof, without stilling well, or Tank with internal floating roof, with stilling well.

If the Tank Type is selected as Tank with Fixed roof, without stilling well, Tank with

Fixed roof, with stilling well, Open Tank, Spherical Tank, or Bullet tank, the fields in the

Floating Roof screen are disabled and the message "This Tank Has No Floating Roof" is displayed.

The Floating Roof screen allows the user to view and modify the details of the tank in terms of the floating roof adjustment type, critical zone details, etc.

To configure the floating roof details

1.

Endress+Hauser

NXA82x_Tank-Details_Floating-Roof

Field

Apply Floating roof adjustment

Floating Roof

Weight

Floating Roof

Adjustment Method

Description

Select the check box to enable Floating roof adjustment (FRA). The text and check boxes of all the floating roof adjustment fields on the screen are now editable.

Clear the check box to disable the floating roof adjustment.

Enter the floating roof weight. This field indicates the weight of the floating roof and is used for the floating roof adjustment factor of the tank, which has a floating roof.

The data type for this field is numeric.

Select the appropriate floating roof adjustment method from the drop down list.The system uses the selected method to calculate the floating roof adjustment of the relevant tank. The methods are as follows:

• FRA in TCT - Floating Roof Adjust is present in TCT, and it should be used for calculating FRA

• FRA not in TCT - Floating Roof Adjust is not present in TCT, and it needs to be calculated using floating roof weight

• Japanese Method - This is a special adjustment method applied primarily in Japan. For details please contact your Endress+Hauser service organisation.

47

The "Tanks" menu - Tank Details Tankvision

Field

Floating Roof

Position for Critical

Zone

Floating roof leg status

Critical Zone – 1 enabled

CZ–1 Lower Level

CZ–1 Upper Level

Critical Zone – 2 enabled

CZ–2 Lower Level

CZ–2 Upper Level

Description

Select the appropriate Floating Roof Position (FRP) for the Critical Zone from the drop down list. This field allows the system to apply the appropriate floating roof position correction factor to the tank, when the floating roof is in the critical zone. The positions are as follows:

• Apply full FRA - When the floating roof is in the critical zone, apply the calculated FRA

• Do not apply FRA: When the floating roof is in the critical zone, do not apply FRA i.e.

FRP status is 1

• Use partial FRA (interpolate): When the floating roof is in the critical zone, interpolate FRP between the critical zone- lower level and upper level based on the product level

• Do not calculate FRA and GOV

Select the appropriate floating roof leg status from the drop down list.

The system uses the floating roof leg status along with the product level and the critical zone level to determine whether the floating roof is landed on the legs, is floating or is in the critical zone.

Select the check box to enable critical zone 1. This field, if selected, enables the fields CZ-1

Lower Level and CZ–1 Upper level. The system uses this field to check if the floating roof is in critical zone 1. Critical zone 1 is used when the floating roof leg status is "raised"

Enter the value for the critical zone 1 lower level. This field is used to check if the tank floating roof is in critical zone 1 (see drawing below).

Enter the value for the critical zone – 1 upper level. This field is used to check if the tank floating roof is in critical zone 1 (see drawing below).

Select the check box to enable critical zone 2.

Clear the check box to disable critical zone 2 .

This field, if selected, enables the fields CZ-2 Lower Level and CZ-2 Upper level.

The system uses this field to check if the floating roof is in critical zone 2.

Critical zone 2 is used when the floating roof leg status is "lowered".

Enter the appropriate value for the critical zone 2 lower level. This field is used to check if the tank floating roofs in critical zone 2 (see drawing below).

Enter the appropriate value for the critical zone 2 upper level. This field is used to check if the tank floating roofs in critical zone 2 (see drawing below).

2.

3.

4.

Enter the appropriate information in the relevant fields.

Click the Submit button to save the tank floating roof details.

After saving the settings, Tankvision displays a confirmation message.

An event is generated after configuring the tank floating roof details. The event details can be viewed in the Event or Alarm & Event overview.

CZ2 (legs lowered)

CZ2 upper level

CZ2 lower level

CZ1 upper level

CZ1 lower level

CZ1 (legs raised)

L00-NXA8xxxx-16-00-00-en-001

PTB "Bruttovolumen":

FRA is applied, settings are sealed if leg status is changed to "lower" (maintenance position) values are no longer displayed as W&M approved.

48 Endress+Hauser

Tankvision The "Tanks" menu - Tank Details

5.5

Flow Calculation

The Flow Calculation screen allows the user to view and modify the details of the tank in terms of flow calculation, minimum level change, minimum flow rate etc.

To configure flow calculation details

1.

Endress+Hauser

Field

Moment detection interval

Minimum level change

Description

Enter the value for the movement detection interval.

The system compares the level data just received with the level data one interval ago.

For example: If the movement detection interval is set at 10 seconds and the system receives new data, it compares the new data with the data received 10 seconds ago. If the change in the product level exceeds the Minimum level change, the system detects that there is movement in the product level. The data type for this field is numeric.

Enter the value for the minimum level change.

This field indicates the minimum change in the product level used to detect the start of a product transfer. The data type for this field is numeric.

Enter the value for the flow calculation window. This field indicates the time period over which the rate of change of the product level is calculated.

Flow calculation window

Minimum level change rate

Major level change rate

Enter the value for the minimum level change rate of the product. This field indicates the minimum rate of change of the product level used to detect the start of a product transfer

The data type for this field is numeric.

Enter the value for the major level change rate of the product.

This field indicates the major rate of change of the product level used to detect the start of a product transfer. The data type for this field is numeric.

Minimum volume change rate

Major volume change rate

Enter the value for the minimum volume change rate of the product.

This field indicates the minimum rate of change of volume of the product used to detect the end of a product transfer. That data type for this field is numeric.

Enter the value for the major volume change rate of the product.

This field indicates the major rate of change of volume of the product used to detect the start of a product transfer. That data type for this field is numeric.

2.

3.

4.

Enter the appropriate information in the relevant fields.

Click the Submit button to proceed to save the flow calculation details.

After saving the changes, Tankvision displays a confirmation message.

An event is generated after configuring the flow calculation details. The event details can be viewed in the Event or Alarm & Event overview.

49

The "Tanks" menu - Tank Details Tankvision

Error Messages

1. "Movement Detection Interval Above Max Value"

This message appears when the value of the Movement detection interval entered by the user is greater than 15 s.

2. "Movement Detection Interval Below Min Value"

This message appears when the value of the Movement detection interval entered by the user is less than 3 s.

3. "Minimum Level Change Below Min Value"

This message appears when the value of Minimum level change entered by the user is less than 0.

4. "Minimum Level Change Above Max Value"

This message appears when the value of Minimum level change entered by the user is greater than 99.

5. "Flow Calculation Window Below Min Value"

This message appears when the value of the flow calculation window entered by the user is less than 5 s.

6. "Flow Calculation Window Above Max Value"

This message appears when the value of the flow calculation window entered by the user is greater than 120 s.

7. "Minimum Level Change Rate Below Min Value"

This message appears when the value of the minimum level change rate entered by the user is less than 0.

8. "Minimum Level Change Rate Above Max Value"

This message appears when the value of the minimum level change rate entered by the user is greater than 999.

9. "Major Level Change Rate Below Min Value"

This message appears when the value of Major level change rate entered by the user is less than 0.

10. "Major Level Change Rate Above Max Value"

This message appears when the value of the major level change rate entered by the user is greater than 999 mm/s.

11. "Minimum Volume Change Rate Above Max Value."

This message appears when the value of the minimum volume change rate entered by user is greater than 999999 m

3

/s.

12. "Minimum Volume Change Rate Below Min Value."

This message appears when the value of the major volume change rate entered by user is less than 0.

13. "Major Volume Change Rate Above Max Value."

This message appears when the value of the major level change rate entered by user is greater than 999999 m

3

/s.

14. "Major Volume Change Rate Below Min Value."

This message appears when the value of the major level change rate entered by user is less than 0.

50 Endress+Hauser

Tankvision The "Tanks" menu - Tank Details

5.6

Water Content

The Water Content screen allows the user to view and modify the details of the tank in terms of water in tank, measurement, status propagation etc.

To configure the water content calculation details

1.

Endress+Hauser

NXA82x_Tank-Details_Water-Content

Field

Free Water in Tank

Water Measurement

Method

Propagate "Fail" Water

Data Status to

Propagate "Not -

Calibrated" Water Data

Status to

Propagate "Manual" Water

Data Status to

Minimum water level

Water volume when water level is not found

Description

Select the check box to enable the system to measure the content of free water in the tank. Clear the check box to prevent the system from measuring the content of free water in the tank. This field indicates whether the tank has water or not. If selected, this field enables the system to perform free water volume calculations.

Select the appropriate water measurement method. The system uses this field to display the water level and Free Water Volume status based on the water measurement method selected.

Select the appropriate option. The system uses this field to propagate a "fail" water data status to "water volume only" or "water and product volume".

Select the appropriate option. The system uses this field to propagate a "Not -

Calibrated" water data status to "water volume only" or "water and product volume".

Select the appropriate option. The system uses this field to propagate a "Manual" water data status to "water volume only" or "water and product volume".

Enter the appropriate value for the minimum water level in the tank.

The minimum water level is used, when water level is not found. The system uses this value, when the water level falls below the minimum water level mark in the tank.

Enter the appropriate value of the water volume, when the water level is not found.

When water level is below the minimum water level, the system treats it as "water not found". In this case, the water volume entered in this field is used as water volume.

2.

3.

4.

Enter the appropriate information in the relevant fields.

Click the Submit button to save the settings, or click the Cancel button to exit.

After saving the settings, Tankvision displays a confirmation message.

An event is generated after configuring the water content calculation details. The event details can be viewed in the Event or Alarm & Event overview.

Error Messages

1. "Invalid Water Volume"

This message appears when the value of the Water volume entered by the user is not a valid real number.

2. "Water volume when not found should be greater than or equal to the minimum value for volume unit"

This message appears when the value of the Water volume entered by user is less than

0 m

3

.

3. "Water volume when not found should be less than or equal to the maximum value for volume unit"

51

The "Tanks" menu - Tank Details Tankvision

This message appears when the value of the Water volume entered by user is greater than 999999 m

3

.

5.7

Hybrid Tank Measurement System

The Hybrid Tank Measurement System (HTMS) screen allows the user to enable a calculation method for the observed density. It is based on input parameters product level,

water level, tank top and bottom pressure, the local gravity (see "Environment Settings",

→ ä 134) and configuration parameters described below.

To configure the HTMS calculation details

1.

Click follows: on

52

Field

HTMS calculation enabled

HTMS Mode

Level P1

Level P3

Minimum Level

Minimum Pressure

Manual Density

Level Hysteresis

Vapor Density

Air Density

Water Density

Description

Select check box to enable the system to calculate the density at measured conditions.

Select the calculation mode from drop down list. Unneeded configuration parameters are greyed out based on the mode selection:

Mode 1: Calculation uses bottom pressure sensor

Mode 2: Calculation uses top and bottom pressure sensor

Distance between pressure sensor 1 (bottom pressure sensor) and datum plate.

Distance between pressure sensor 3 (top pressure sensor) and datum plate.

Minimum input level value to start the calculation. Otherwise an error condition is used.

Minimum input pressure to start the calculation. Otherwise an error condition is used.

In Mode 1 bottom pressure value is used, in Mode 2 the difference between top and bottom pressure values is used.

Density value for error conditions

Hysteresis value applied to the level value at minimum level condition

Density value for the vapor density

Density value for the air density

Density value for the water density

2.

Enter the appropriate information in the relevant fields.

3.

4.

Click the Submit button to save the settings.

After saving the settings, Tankvision displays a confirmation message.

Error Messages

1. "Wrong format"

This message appears when the entered value is not a valid real number.

Endress+Hauser

Tankvision The "Tanks" menu - Tank Details

5.8

Inventory Calculation

The Inventory Calculation screen allows the user to view and modify the details of the tank in terms of tank inventory calculations.

To configure the tank inventory calculation details

1.

Field

Minimum Tank

Inventory

Description

Enter the minimum tank inventory. This field indicates the minimum tank inventory value. The product transfer cannot be considered as W&M approved, if the product level in the tank at the beginning or end of product transfer is less or equal than the configured value.

The data type for this field is numeric.

Minimum Batchsize Enter the minimum batch size. This field indicates the minimum batch size value. The product transfer cannot be considered as W&M approved, if the batch size for the product transfer is less than the minimum batch size. The data type for this field is numeric.

2.

3.

4.

Enter the appropriate information in the relevant fields.

Click the Submit button to save the inventory calculation details.

After saving the settings, Tankvision displays a confirmation message.

An event is generated after configuring the inventory calculation details. The event details can be viewed in the Event or Alarm & Event overview.

Endress+Hauser 53

The "Tanks" menu - Tank Details Tankvision

5.9

Put Tank into Calibrated Status

Tankvision generates various tank inventory reports and displays tank inventory data on web pages. A report or data displayed on the report can be W&M approved only if the tank is W&M calibrated. The user can set the tank and tank parameters into the W&M calibrated status. Once the tank is set in the W&M calibrated status, it means the tank configuration is

W&M approved.

Subsequently, the system becomes W&M approved only after the W&M switch is "closed".

The W&M switch is protected by a mechanical W&M seal (sticker). Only a W&M official or an accredited person can put the W&M seal.

The configuration of a tank that is marked as W&M calibrated cannot be modified after the

W&M switch is closed.

To set the tank into calibrated status

1.

54

NXA82x_Put-Tank-into-Calibrated-status

Field

Tank Name

Tank

Product Level

Product Temperature

Total Observed

Volume (TOV)

Description

This field displays the name of the tank.

Select the check box to calibrate the tank.

Select the check box to calibrate the tank parameter:

• Product level

• Product Temperature

• Total Observed Volume (TOV)

The tank measured parameter can be marked as calibrated in auto mode or manual mode. Based on the actual parameter mode, the respective measured parameter calibrated status marked here is used to determine the calibrated status of the measured parameters, and therefore subsequently for calculated parameters.

2.

3.

4.

Enter the appropriate information in the relevant fields.

Click the Submit button to save the settings, or click the Reset button to reset the screen.

After saving the settings, Tankvision displays a confirmation message.

Observe the following information regarding the calibrated status!

• The W&M calibration status of the tank and tank parameters is propagated into reports and user interface pages.

• The W&M switch status should be "open" before setting the tank and tank parameters into the calibrated status.

• The W&M switch status should be changed to "close" after setting the tank and tank parameters into the calibrated status.

• An event is generated after creating or modifying the product. The event details can be viewed in the Event or Alarm & Event overview.

• In case of a closed W&M switch, a tank or its parameters can be taken out of the calibrated status, but puting it back or adding further tanks to W&M is not possible.

Please note that changes in a configuration of a W&M approved system must be announced to the authorities (depending on local laws and regulations).

Endress+Hauser

Tankvision The "Tanks" menu - Tank Details

5.10

HART command

If available, Tankvision routes the communication from a field device parametrization tool

(e.g. FieldCare) to a field device (e.g. Tank Side Monitor and its connected HART devices), via the field protocols Modbus and V1 (so called HART tunneling).

Creating/Disconnecting the HART tunnel is done automatically.

NXA82x_Tank-Details_HART-Command

Endress+Hauser 55

The "Tanks" menu - Alarm Settings Tankvision

6 The "Tanks" menu - Alarm Settings

Alarms are configured in order to define the "Hysteresis" value, the "hold off time" and various alarm set points for each tank and its parameters. The alarm settings screens allow you to store the e-mail address of an operator, so that he receives notifications for various alarms.

To configure alarms

1.

On the Navigation Tree, click the Tanks header. (The number of tanks configured is displayed in brackets next to the Header’s name.) Tankvision displays the screen as follows:

2.

3.

Select the appropriate tank.

Click the Modify button to modify the tank details. Tankvision displays the Tank

Details screen as follows:

Button Manage Tank:

Go back to the Manage Tanks Screen by clicking on the button Manage Tanks.

4.

Click the Alarm Settings tab. Tankvision displays the Alarm Settings screen as follows:

56 Endress+Hauser

Tankvision The "Tanks" menu - Alarm Settings

6.1

Measured Data Alarm Configuration

The Measured Data Alarm Configuration screen allows you to define set points for measured tank parameters such as the product levels, product temperature, pressure and

density. Please refer to Chapter "Types of Alarms" (→ ä 220) for an explanation of alarm

types.

To configure alarms for measured data

1.

Click follows: on

Endress+Hauser

NXA82x_Alarm-Settings_Measured-Data-Alarm-Configuration

Column

Unit Type

Description

This column displays a list of parameter types for which alarms can be set.

Unit

Tank Parameters

This column displays the Units corresponding to the parameters.

This column displays the different Tank parameters for which the set points are configured.

This column displays the current value of the corresponding tank parameters.

Current value

HH alarm set point Enter the appropriate value for the HighHigh alarm set point.

This set point is used to detect whether the Product Level or Secondary Product Level has reached their respective HH alarm value. The HH alarm set point should be greater than set point for High alarm for level and less than the Gauge Reference Height. The data type for this field is numeric.

1)

HA alarm set point Enter the appropriate value for the HighAlarm set point. This set point is used to detect whether any of the following parameters have reached their respective HA alarm value, namely:

Product Level, Secondary Level, Water Level, Product Temperature, Vapor Temperature,

Vapor Pressure and Observed Density. The HA Alarm set point should be less than the

HH alarm for the corresponding parameter and less than the Gauge Reference Height.

The data type for this field is numeric.

MF alarm set point Enter the appropriate value for the Max Fill Alarm.

This alarm does apply for Product Level only. The MF alarm set point must be smaller than a configured HA alarm and greater than a configured LA alarm.

LA alarm set point Enter the appropriate value for the LowAlarm set point.

This set point is used to detect whether any of the following parameters have reached their respective LA alarm value, namely:

Product Level, Secondary Level, Product Temperature, Vapor Temperature, Vapor

Pressure and Observed Density.

The LA alarm set point should be greater than the LL alarm for the corresponding parameter and less than the Gauge Reference Height. The data type for this field is numeric.

LL alarm set point Enter the appropriate value for the LowLow alarm set point.

This set point is used to detect whether the Product Level or Secondary Product Level has reached their respective LL alarm value. The LL alarm should be smaller than or equal to the LL alarm for the product level, and less than the Gauge Reference Height. The data type for this field is numeric.

57

The "Tanks" menu - Alarm Settings Tankvision

Column Description

DF alarm set point Enter the appropriate value for the DF alarm set point. DF alarm means "Difference

Alarm" and is raised when the difference between the product level and the secondary level exceeds the set point value configured for DF alarm. The data type for this field is numeric.

CH alarm set point Enter the appropriate value for the CH alarm set point. CH alarm means "Change Alarm" and is raised when the difference between the product level at LOCKED state of the tank and the current product level exceeds the set point value configured for CH alarm. The data type for this field is numeric.

Enable Data and Fail

Alarm

Select the appropriate check boxes to enable data and fail alarm for the relevant tank parameters. Clear the appropriate check boxes to disable data and fail alarm for the relevant tank parameters.

Hysteresis Value

Hold off Time

(seconds)

Enter the appropriate Hysteresis Value in the text box.

The hysteresis is applied to the respective alarm set points to prevent false toggling of the alarm status between "active" and "inactive" which might happen due to fluctuations in the measured value. For example, the product level could fluctuate due to waves on the product surface.

The data type for this field is numeric.

Enter the appropriate hold off time in the text box.

The hold off time is triggered when the actual value crosses the configured set point for an alarm. The alarm becomes active only after the actual value stays above or below the respective alarm set point for a time more than or equal to the hold off time. This prevents false alarm generations due to spikes in the actual values of data.

The data type for this field is numeric.

1) A secondary level can be the position of a floating roof, for example. It might be useful to measure the product level and the floating roof position, to check if the floating roof always follows the product level and does not get stuck.

Field

E-Mail Address

Description

Enter the e-mail address of the user to whom the e-mail notification is to be sent whenever a new alarm is generated. The data type of the field is "text", which can accept valid e-mail addresses.

2.

Enter the appropriate information in the relevant fields.

3.

4.

Click the Submit button to configure the measured data alarm.

After saving the settings, Tankvision displays a confirmation message.

An event is generated after configuring the alarm set points. The event details can be viewed in the Event or Alarm & Event overview.

Error Messages

1. "... Alarm Values are not in Order."

This message appears in each of the following cases:

– The value of a High High Alarm (HH Alarm) is lower than the value of a High Alarm

(H Alarm), a Low Alarm (L Alarm) or a Low Low Alarm (LL Alarm).

– The value of a High Alarm (H Alarm) is lower than the value of a Low Alarm (L Alarm) or Low Low Alarm (LL Alarm).

– The value of a Low Alarm (L Alarm) is lower than the value of a Low Low Alarm (LL

Alarm).

2. "... Level Alarm Values Cannot be Greater Than GRH."

This message appears when Product Level Alarm values, entered by the user, are greater than Maximum Gauge Reference Height.

58 Endress+Hauser

Tankvision The "Tanks" menu - Alarm Settings

6.2

Calculated Data Alarm Configuration

The Calculated Data Alarm Configuration screen allows the user to set various alarm set points for tank parameters such as product volume, mass, rate in change of product level, flow rate, hysteresis value and the hold off time.

To configure alarms for calculated data

1.

Click follows: on

Endress+Hauser

Column

Unit Type

Units

Parameter

Current value

HA Set Point

LA Set Point

Data Fail

Hysteresis

Hold off Time

(Seconds)

NXA82x_Alarm-Settings_Calculated-Data-Alarm-Configuration

Description

This column displays a list of the parameters types for which alarms can be set.

This column displays the Units corresponding to the parameters.

This column displays different parameters for which the set points are configured.

This column displays the current value of the corresponding parameters.

Enter the appropriate value for the HighAlarm set point. This set point is used to detect, whether any of the following parameters have reached their respective HA alarm value, namely: Total Observed Volume (TOV), Gross Observed Volume (GOV), Gross Standard

Volume (GSV), Mass in Vacuum and Flow Rate. The data type for this field is numeric.

Enter the appropriate value for the LowAlarm set point. This set point is used to detect whether any of the following parameters have reached their respective L alarm value, namely: Total Observed Volume (TOV), Gross Observed Volume (GOV), Gross Standard

Volume (GSV) and Mass in Vacuum. The data type for this field is numeric.

Select the appropriate check boxes to enable the data fail alarm for the relevant parameters.

Clear the appropriate check boxes to disable the data fail alarm for the relevant parameters.

Enter the appropriate Hysteresis Value in the text box. The hysteresis is applied to the respective alarm set points to prevent false toggling of the alarm status between "active" and "inactive", which might happen due to fluctuations in the measured value. For example, the product level could fluctuate due to waves on the product surface. The data type for this field is numeric.

Enter the appropriate hold off time in the text box. The hold off time is triggered when the actual value crosses the configured set point for an alarm. The alarm becomes active only after the actual value stays above or below the respective alarm set point for a time more than or equal to the hold off time. This prevents false alarm generations due to spikes in the actual values of data. The data type for this field is numeric.

Field

E-Mail Address

Description

Type the e-mail addresses of the user to whom the e-mail notification is to be sent, whenever new alarm is generated. The data type of the field is text, which can accept valid e-mail addresses.

2.

Enter the appropriate information in the relevant fields.

59

The "Tanks" menu - Alarm Settings Tankvision

3.

4.

Click the Submit button to configure the calculated data alarm.

After saving the settings, Tankvision displays a confirmation message.

An event is generated after configuring the alarm set points. The event details can be viewed in the Event or Alarm & Event overview.

Error Messages

1. "Volume Hysteresis Value not in range."

This message appears when the value of the Volume Hysteresis entered by the user is not between 0 to 999999.999 m³.

2. "Mass Hysteresis Value not in range."

This message appears when the value of the Mass Hysteresis entered by the user is not between 0 to 999999999 kg.

3. "Rate of Change of Level Hysteresis Value not in range."

This message appears when the value of the Rate of Change of Level Hysteresis Value entered by the user is not between -999.99 to 999.99 mm/s.

4. "Rate of Change of Volume Hysteresis Value not in range."

This message appears when the value of the Rate of Change of Volume Hysteresis entered by the user is not between -999999.99 to 999999.999 m³/min.

5. "TOV High Alarm Set Point Value not in range."

This message appears when the value of the TOV High Alarm Set Point entered by the user is not between 0 to 999999.999 m³.

6. "TOV Low Alarm Set Point Value not in range."

This message appears when the value of the TOV Low Alarm Set Point entered by the user is not between 0 to 999999.999 m³.

7. "GOV High Alarm Set Point Value not in range."

This message appears when the value of the GOV High Alarm Set Point entered by the user is not between 0 to 999999.999 m³.

8. "GOV Low Alarm Set Point Value not in range."

This message appears when the value of the GOV Low Alarm Set Point entered by the user is not between 0 to 999999.999 m³.

9. "GSV High Alarm Set Point Value not in range."

This message appears when the value of the GSV High Alarm Set Point entered by the user is not between 0 to 999999.999 m³.

10. "GSV Low Alarm Set Point Value not in range."

This message appears when the value of the GSV Low Alarm Set Point entered by the user is not between 0 to 999999.999 m³.

11. "Mass in Vacuum High Alarm Set Point Value not in range."

This message appears when the value of the Mass in Vacuum High Alarm Set Point entered by the user is not between 0 to 999999999 kg.

12. "Mass in Vacuum Low Alarm Set Point Value not in range."

This message appears when the value of the Mass in Vacuum Low Alarm Set Point entered by the user is not between 0 to 999999999 kg.

13. "Level Change Rate CH Alarm Set Point Value not in range."

This message appears when the value of the Level Change Rate CH Alarm Set Point entered by the user is not between -999.99 to 999.99 mm/s.

14. "Volume Flow Rate High Alarm Set Point Value not in range."

This message appears when the value of the Volume Flow Rate High Alarm Set Point entered by the user is not between 0 to 999999.999 m³.

15. "Tank not configured. This tank has no alarms configured."

This message appears when the user has no alarms configured.

60 Endress+Hauser

Tankvision The "Tanks" menu - Gauge Commands

7 The "Tanks" menu - Gauge Commands

The Gauge commands that are available for a tank are dependent on the gauge type.

Information about gauge commands supported by a particular gauge is stored in a "gauge definition file". This enables the Tankvision system to retrieve the list of gauge commands from the gauge definition file. This function comes in use when you need to enable or disable a gauge command.

The Configure Gauge Commands screen allows you to enable or disable the gauge commands as per the system requirements.

To configure a gauge command

1.

On the Navigation Tree, click the Tanks header. (The number of tanks configured is displayed in brackets next to the Header’s name.) Tankvision displays the screen as follows:

2.

3.

Click the appropriate option to select the tank name.

Click the Modify button to modify the tank details. Tankvision displays the Tank

Details screen as follows:

4.

Click the Gauge Commands tab. Tankvision displays the screen as follows:

Endress+Hauser 61

The "Tanks" menu - Gauge Commands Tankvision

62

NXA82x_Gauge-Commands

Column

Gauge Command

Description

Enable

Description

This column displays a list of gauge commands available for that particular tank and gauge type. For the meaning of the gauge commands refer to the manual of the Proservo or Servo, respectively. Examples:

• Level: follow medium to measure the product level

• UP: move the displacer up into the housing of the gauge (e.g. for maintenance)

• Stop: hold the displacer at the current position whatever happens.

This column displays a short description of the corresponding gauge command.

Select the appropriate check boxes to enable the gauge commands that are required.

Clear the appropriate check boxes to disable the gauge commands that are not required.

Only the enabled gauge commands can be scheduled or sent to the tank.

By default, the system selects all the check boxes in the Enable column.

5.

6.

The tank has to be configured for field scan before configuring the gauge command

(System → Global Settings → Field Scan → Manage Field Scan Configuration). If the tank is not configured for field scan, the list of gauge commands will not be displayed on this screen.

Enter the appropriate information in the relevant fields.

Click the Submit button to configure the gauge commands. Tankvision displays a confirmation screen as follows:

7.

8.

Click the OK button to change the Gauge Configuration.

After saving the settings, Tankvision displays a confirmation message.

The system generates an event, when a Gauge Command is configured. This information can be viewed in the Event or Alarm & Event tab.

Endress+Hauser

Tankvision The Tank Details screen

8 The Tank Details screen

The Tank Details screen is used to display real time tank data dynamically and to perform typical tank farm operations (e.g. tank-product assignment, product transfers, ...).

The Tank Details screen contains various tabs which are used for the different tasks.

To view the Tank Details screen

1.

On the Navigation Tree, click the Tanks header. The Tanks header expands as follows:

NXA82x_Menu_Tanks

2.

Click the <Tank Name> of the tank you are going to work on. Tankvision displays the screen as follows:

Endress+Hauser

NXA82x_Tank_General-Details-Tab

63

The Tank Details screen

8.1

The "General Details" tab

The General Details tab displays the most important tank data dynamically.

To view the "General Details" tab

On the Tank Details screen, click the General Details tab.

Tankvision displays the screen as follows:

Tankvision

NXA82x_Tank_General-Details-Tab_Measured-Values

Use the scrollbar on the right to see more parameters.

Column Description

Measured Values

Tank Display and

Alarm Set Point

Calculated Values

This area displays the measured values of the product or tank parameters in terms of temperature, pressure, density and water level along with their respective units of measurement. The date and time at which the value of each parameter has changed is also displayed along with the measured valued. Status:

• OK

Ok Status

• INIT

Field Scan started, value not yet received and processed

• MANUAL

Value set to manual

• NODATA

Calculation not configured, Field Scan is off

• INVALIDDATA

Calculation is out of boundaries

• LASTVALIDVALUE

Value is set on HOLD, need additional servo configuration

• FAIL

Communication error on field protocol of device configuration

This area displays the picture of the tank and the corresponding Alarm Set Points for that particular tank.

This area displays the calculated values of the product parameters in terms of volume, tank capacity, reference density, floating roof adjustment, product and vapor mass along with their respective units of measurement.

Product transfer

Details

This area displays the status and details of the product transfer.

Configuration Data This area displays the configuration data used for calculation.

64 Endress+Hauser

Tankvision The Tank Details screen

8.1.1

Configuring the "General Details" tab

Which parameters are displayed in the General Details tab can be configured in the

Configure Tank parameters pop-up.

To view the "Configure Tank parameters" pop-up

On the General Details tab, click the Click here to configure link.

Tankvision displays a pop-up as follows:

Endress+Hauser

NXA82x_Tank_General-Details-Tab_Configure-Tank-parameters-Pop-Up

To configure the displayed parameters

1.

Use the arrow buttons to transfer the parameters from the Available Measured/

Calculated Parameters list to the Selected Measured/Calculated Parameters list and vice versa. (Several parameters can be selected by holding the Ctrl key with clicking on the parameters.)

2.

Click the Submit button to save the configuration and return to the General Details tab.

The configuration is changed for all tanks.

65

The Tank Details screen Tankvision

8.2

The "Spot Temperature" tab

The Spot Temperature tab displays measured values from the spot elements of an average temperature probe.

To view the "Spot Temperature" tab

On the Tank Details screen, click the Spot Temperature tab. Tankvision displays the screen as follows:

Column

Spot Temperature

Values

Description

Displays measured values from the spot elements of an average temp. probe (e.g.

NMT539).

The date and time at which value of each parameter has changed is also displayed along with the measured value.

66 Endress+Hauser

Tankvision The Tank Details screen

8.3

The "Manual Data" tab

The Manual Data tab gives you the option of entering values for the product level, temperature, density and pressure manually.

To enter manual data

1.

Click the Manual Data tab. Tankvision displays the screen as follows:

Endress+Hauser

NXA82x_Manual-Data_Set-Configure-Manual-Parameters

Column Description

Available Parameter This column displays the tank parameters which are available to be set into manual mode.

Selected Parameter This column displays the tank parameters which are currently in manual mode.

Field

Manual Overwrite

Date

Manual Overwrite

Time

Description

Enter the appropriate date in the text box. This date will be used as time stamp for the manually entered value. The data type for this field is date.

Enter the appropriate time in the text box. This time will be used as time stamp for the manually entered value. The data type for this field is time.

2.

3.

4.

Enter the appropriate information in the relevant fields.

Click the Submit button.

After saving the settings, Tankvision displays a confirmation message.

An event is generated after manually entering a value for a tank parameter. The event details can be viewed in the Event or Alarm & Event overview.

67

The Tank Details screen Tankvision

8.4

The "Dipped Data" tab

The Dipped Data tap give you the option of entering dipped values for the product level, water level, product temperature, observed density with acc. sample temperature and the reference density.

NXA82x_Tank_Dipped-Data-Tab

Field

Product level

Description

Enter dipped values for the product level. Activate the field by enabling the check box in the beginning of the column.

Water level Enter dipped values for the water level. Activate the field by enabling the check box in the beginning of the column.

Product temperature Enter dipped values for the product temperature. Activate the field by enabling the check box in the beginning of the column.

Date and Time Enter the appropriate Date and Time in the text box / drop down list. This time will be used as time stamp for the manually entered value. The data type for this field is time.

68 Endress+Hauser

Tankvision The Tank Details screen

8.5

The "Gauge Commands" tab

Every gauge supports a specific set of commands. The Tankvision system supports these gauges and stores their data and corresponding gauge commands in "gauge definition files".

The functionality of gauge commands is dependent on the gauge type assigned to the tank, whereas completion of a gauge command is based on the gauge status or gauge commands status. The Tankvision system retrieves these commands from the "gauge definition files"

during the configuration of gauge commands (→ ä 61). Gauge commands can be scheduled

and sent only by an authorized user. Most of these commands are unique for servo gauges.

You can send a gauge command to a gauge installed on a tank manually or even schedule a gauge command to be sent automatically.

8.5.1

Schedule Gauge Command

The Tankvision system allows the user to schedule gauge commands, such that they can be executed either immediately or at a certain time. An operator can schedule a gauge command only if that particular gauge command is enabled in the Gauge Command configuration screen.

To schedule a gauge command

1.

Click the Gauge Commands tab. Tankvision displays the screen as follows:

2.

Endress+Hauser

NXA82x_Tank_Gauge-Commands-Tab

Field

Gauge Type

Gauge Command

Schedule Type

Description

This field displays the Gauge Type.

Select the appropriate gauge command from the drop down list.

The data type for this field is "character".

Select the appropriate Schedule type from the drop down list. The gauge command can be scheduled to be sent once or scheduled for automatic repetition.

Sent Once: Select "sent once" to enable the gauge command to be sent only once.

Automatic Repetition: Select "automatic repetition" to enable the Interval field.

This field allows you to schedule the system to send a particular gauge command periodically. The data type for this field is "character".

69

The Tank Details screen Tankvision

Field

Interval

Date

Status

Description

Enter the appropriate interval in the text box. This field is enabled if the Schedule Type for the gauge command is selected as Automatic Repetition. The data type for this field is "numeric".

Also, in the adjacent text box:

Select the appropriate unit for the interval from the drop down list. The system allows you to schedule the interval for the gauge commands in terms of hours or minutes.

The data type for this field is character.

Enter or select the appropriate date from the drop down calendar.

The Tankvision system allows you to select the date on which the gauge command is to be sent. The data type for this field is alphanumeric.

Also, enter or select the appropriate time in terms of hours and minutes from the respective drop down lists. The Tankvision system allows you to select the exact time at which the gauge command is to be sent. If the Schedule Type for a gauge command is

"automatic repetition", then the time entered in the text boxes indicates the first time the gauge command is to be sent. The data type for this field is numeric.

Select the appropriate option. This field indicates the status of the gauge command. This field allows you to enable or disable a gauge command.

3.

Enter the appropriate information in the relevant fields.

4.

5.

Click the Submit button to send a gauge command, or click the Reset button to exit.

After saving the settings, Tankvision displays a confirmation message.

The system generates an event, when the Gauge Command is sent. This information can be viewed in the Event or Alarm & Event tab.

Error Messages

1. "Cannot send gauge command while tank status is Manual, In Maintenance, or Locked."

This message appears when the user sends a gauge command while tank status is

"Manual", "In Maintenance" or "Locked".

70 Endress+Hauser

Tankvision The Tank Details screen

8.5.2

Send Gauge Command

The Tankvision system allows you to send commands to a gauge installed on a tank. A gauge command can be sent only if that particular command is enabled for the tank in the Gauge

Command configuration screen. Once a gauge command is sent, it remains active till the system receives an appropriate response from the gauge. The response for a gauge command depends on the gauge and communication protocol.

To send a gauge command

1.

Click the Gauge Commands tab. Tankvision displays the screen as follows:

2.

Endress+Hauser

NXA82x_Gauge-Commands_Send-Gauge-Command

Field

Product level

Product temperature

Status

Date and Time

Description

Displaying Product Level and Product Temperature incl. Status

Displaying Active Gauge Command and issuing Date and Time

Column

Select

Gauge Command

Command

Parameters

Description

Description

Select the appropriate gauge command option corresponding to the gauge command name.

The radio buttons are highlighted only if the corresponding gauge commands are configured in the Gauge Command screen.

This column displays a list of gauge commands in abbreviated form.

Enter additional parameter to a gauge command which is send to the connected gauge.

This column displays a short description corresponding to each gauge command.

3.

4.

Select the appropriate gauge command option.

Click the Send button to activate the gauge command.

71

The Tank Details screen Tankvision

5.

After saving the settings, Tankvision displays a confirmation message as follows:

6.

In the above figure, all options in the Select column are disabled, except the Stop option.

If the gauge command has to be stopped, then select the stop option, and click the Send button.

If another gauge command needs to be sent, it might be necessary to cancle the acitve command by sending the STOP command prior issuing the new command.

The system generates an event, when a Gauge Command is activated. This information can be viewed in the Event or Alarm & Event tab.

Error Messages

1. "Cannot send gauge command while tank status is Manual, In Maintenance, or Locked."

This message appears when the user sends a gauge command while the tank status is

"Manual", "In Maintenance" or "Locked".

72 Endress+Hauser

Tankvision The Tank Details screen

8.6

The "Real Time Trend" tab

The Tankvision system collects data from the tanks and monitors these values using a trend.

A trend is a line graph which gives a pictorial representation of the recent changes of the measured values over time. The Real Time Trend is hosted in the Tankvision unit. It depicts the real-time measured or calculated values of a selected tank as a function of time in the form of a line chart.

The system has default settings which can be customized as required for each tank element and will eventually be plotted on the trend. Up to 4 values can be plotted in one chart.

To view a real time trend

1.

Click the Real Time Trend tab. Tankvision displays the screen as follows:

Column

Pen

Parameter Name

Description

This column displays a list of pens (Pen 1, Pen 2, Pen 3 and Pen 4) that are used to identify the parameters selected.

Select the appropriate parameter from the drop down list.

2.

Select the appropriate parameter name for each pen and click the Submit button.

Tankvision displays the screen as follows:

Endress+Hauser 73

The Tank Details screen

4 1 3

Tankvision

74

2

NXA82x_Real-Time-Trend_View

2

3

Pos.

Field

1 Trend Graphic Area

Description

The Trend Graphic Area includes a rectangular chart with Tank Elements drawn using a specified pen configuration.

Trend Setting

Line Graphs

The Trend Setting area allows the user to configure the trend view.

The line graphs are displayed based on the selection of tank parameters in the

Trend Setting area.

4 Plotter The plotter can be moved through the graphic area. According to the position of the plotter values are displayed in the row value field.

Field

Zoom

Pan

Description

The Zoom icons allow you to make changes to the current time window. The zoom is specified in terms of the percentage of the time window. The current zoom level reflects the width (time interval) of the plotting area.

The Zoom-In is possible maximum up to 20 seconds.

possible up to 24 hours.

The Zoom-Out is

The Pan icons allow you to make changes in the current time window displayed in trend.

The Go First button rewinds the trend to the oldest available values in the rolling data buffer of the trend.

The Go Previous button shows the previous time window.

The Go Next button shows the next time window.

The Go Last button shows current or latest values in the trend.

Endress+Hauser

Tankvision

Endress+Hauser

The Tank Details screen

Field

Show

Tank Parameter

Value

Data Status

Units

Pen Color

Pen Style

Description

Select the appropriate check boxes to view the line graphs of the relevant tank parameter.

Clear the appropriate check boxes to prevent the system from creating line graphs of the relevant tank parameter.

This column displays the list of parameters for which the user can view line graphs.

The value column shows the tank parameter value at the current plotter position. The date and time are displayed on the header bar of the Value column. The value is shown for those tank parameters that are currently selected to be displayed on the trend or if the value at plotter position has not the status "fail". In this case the system displays the row in light blue color.

This column displays the status of the data. Only those values are plotted, whose status is

OK.

This column displays the units of the tank parameter.

Click the color palette to select the unique color for the line graph.

This column displays the pen colors used to draw the graphical line which depicts the value of the particular tank parameter on the trend.

Click the Pen Style to select the line style for depicting the relevant parameters.

This column displays the style of the graphical line which depicts the values of the particular tank parameter on the trend.

To plot the trend, click on the Trend Graphic Area. The plotter moves in real-time. The

Trend Setting area shows the values of all parameters plotted at the plotting cursor position.

8.7

The "Product Transfer" tab

The product transfer is a day-to-day tank farm operation. During the tank farm operation, a product is pumped into or out of a tank. A tank may receive product from a pipeline, tanker, ship or another tank. When the product is to be filled into a tank, it is necessary to check the available tank capacity. Similarly, when the product is to be pumped out of a tank, it is necessary to check the product volume in the tank. Tankvision allows an operator to create a new product transfer.

Tankvision does not control the product transfer, but it monitors product transfers and generates product transfer data and reports. When a company sells the product stored in tanks to another company, it is important that the tank is W&M (weights and measurement) certified for correct measurements. The Tankvision system provides this facility by calibrating the system and then gets it W&M approved. All tanks which are W&M certified can be used for custody transfers.

In this case the product transfer report (→ ä 88) will mention the W&M approved status,

which can be used to prove that the correct amount of product has been transferred.

8.7.1

Product Transfer Life Cycle

The Tankvision system allows the user to create, finish or abort a product transfer. Once a product transfer is created, the system monitors the product transfer to detect "start of transfer (active)", "product transfer paused" or "product transfer completed".

The life cycle of a product transfer

The product transfer traverses through its life cycle as follows:

• Create a product transfer for a tank

• Detection of the start of the product transfer

• Detection of a paused transfer

• Detection of a completed transfer

• Transfer finished or aborted

• Product transfer report

75

The Tank Details screen

To transfer a product for a tank

1.

Click the Product Transfer tab. Tankvision displays the screen as follows:

Tankvision

Field Description

Source/Destination The system displays the status of inflow or outflow of the product. If the transfer type is In, then this field displays Source. If the transfer type is Out, then this field displays

Destination.

Transfer Type Select the appropriate product transfer type from the drop down list. This field enables the system to allow transfer of the product into or out of the tank depending on the selected option, viz., In or Out.

In: A product is being filled into a tank.

Out: A product is being pumped out from a tank.

This field is disabled after creating a new product transfer.

Batch Mode

Batch Size

Select the appropriate batch mode from the drop down list. This field allows you to select the mode of product transfer. The batch mode is Volume or Mass.

Volume: The quantity of product to be transferred is specified as Total Observed Volume

(TOV) of product.

Mass: The quantity of product to be transferred is specified as product Mass.

This field is disabled after creating a new product transfer.

Enter the appropriate batch size in the text box. This field displays the quantity of the product that is being transferred. The unit depends on whether the mode of product transfer is in volume or mass. The data type for this field is numeric.

76 Endress+Hauser

Tankvision

Endress+Hauser

The Tank Details screen

Field

Batch Deviation

Percentage

Description

Minimum Maximum

Enter the minimum batch percentage.

This field is used to determine, whether the product transfer is complete or not. The product transfer is considered as completed, if:

• The quantity of product that has been transferred so far (calculated as per batch mode) is equal to or more than the minimum batch deviation percentage of the batch size, and ...

Enter the maximum batch percentage.

This field is used to determine, whether the product transfer is complete or not. The product transfer is considered as completed, if:

• If the batch exceeds the max. batch percentage an event is generated.

• The quantity of product that has been transferred so far (calculated as per batch mode) is equal to or more than the minimum batch deviation percentage of the batch size and is less than the maximum batch deviation percentage of the batch size; and ...

• ... the rate of change of volume is less than the minimum rate of change of the volume

(Chap. 5.5, → ä 49)

The data type for this field is numeric.

Batch [%]

Max.

100%

Min.

0 t

Pre Alarm

Percentage

Comments

Enter the pre-alarm percentage. If the quantity of product transfered (calculated as per the batch mode) increases above the pre alarm percentage of the batch size for In transfer or decreases below the pre-alarm percentage for Out transfer, then the system raises a prealarm.

The data type for this field is numeric.

Enter the appropriate comments in the comments field. This field allows the user to enter comments related to the product transfer. This information is captured in the product transfer report. The data type for this field is characters.

E-Mail Addresses Enter the appropriate e-mail addresses. Whenever the product transfer is completed, the system sends a product transfer report by e-mail to the e-mail addresses entered in this field.

Transfer Status This field displays the status of the product transfer. The product transfer status can be:

"Armed", "Active", "Paused", "Completed", "Finished" or "Aborted".

• "Armed" (Ready to start)

• "Active" (In progress)

• "Paused" (On hold)

• "Completed" (if min. batch dev. percentage is reached 0 and flow goes to 0)

• "Finished" (tank transfer finished)

• "Aborted" (stop immediately before finishing)

2.

3.

4.

Enter the appropriate information in the relevant fields.

Click the Submit button to create a new product transfer.

After saving the settings, Tankvision displays a confirmation message.

An event is generated after creating a product transfer. The event details can be viewed in the Event or Alarm & Event overview.

77

The Tank Details screen Tankvision

8.7.2

Status of a Product Transfer

Create a New Product Transfer

Creating a new product transfer is the first step to be followed after the pre-condition for product transfer is set in the system. While creating a new product transfer, the transfer status of the tank should be "None". The product transfer status "None" means that the tank does not have any product transfer associated with it in the Armed or Active status, and thus a new product transfer can be created. An image of Tankvision displaying the status as

"None" is as follows:

Validate product transfer details

Once the user has created a new product transfer for a tank, this tank is said to be "Armed" for product transfer. The system starts monitoring a tank (with status) "Armed" to automatically detect the start of the product transfer. Auto detection of start of Product

transfer defined in Chapter "Flow Calculation", → ä 49). Once a tank is armed for a product

transfer, no other product transfer can be created for the tank, unless the existing transfer is cancelled.

An image of Tankvision displaying the status as "Armed" is as follows:

78

The system generates an event when the status is changed from "None" to "Armed". This information can be viewed in the Event or Alarm & Event tab.

Endress+Hauser

Tankvision The Tank Details screen

Detection of the start of a product transfer

Once the product transfer has been armed, the system detects the start of the product transfer based on a change in the level and the rate of change of the level. The system treats the product transfer as started and the product transfer status is changed to "Active" if:

• The change in product level is greater than the minimum level change, and

• The rate of change of level is greater than the minimum rate of change of level configured under the flow calculation details

Once a tank is in the "Active" status for a product transfer, no other product transfer can be created for the tank, unless the active transfer is Finished or Aborted.

An image of Tankvision displaying the status as "Active" is as follows:

Endress+Hauser 79

The Tank Details screen Tankvision

Product transfer paused

The system treats an Active product transfer as Paused and the product transfer status is changed to "Paused" if:

• The flow rate drops below the minimum volume change rate,

• the rate of change of level drops below the minimum rate of change of level configured under the tank flow calculation details, and

• the quantity of product that has been transferred is less than the minimum batch deviation percentage of the batch size

An image of Tankvision displaying the status as "Paused" is as follows:

80 Endress+Hauser

Tankvision The Tank Details screen

Product transfer completed

The product transfer is considered as completed, if:

• the quantity of product that has been transferred so far (calculated as per batch mode) is equal to or more than minimum batch deviation percentage of batch size, and is less than the maximum batch deviation percentage of the batch size; and

• the rate of change of volume is less than the minimum rate of change of volume

An image of Tankvision displaying the status as "Completed" is as follows:

Endress+Hauser

The system generates an event for a completed product transfer. The event details can be viewed in the Event or Alarm & Event tab.

81

The Tank Details screen Tankvision

Product transfer finished

The user may choose to finish the product transfer before the product transfer is completed.

The product transfer can be finished, when the tank is in an "Active" transfer stage.

An image of Tankvision displaying the status as "Finished" is as follows:

Observe the following information regarding the product transfer!

• The system displays a pop up message to confirm about finishing the product transfer.

• When the user manually finishes the product transfer, the system generates and displays the "Product Transfer Report".

• The system generates an event for product transfer finished by user. The information can be viewed in the Events or Alarm & Event tab.

• The user cannot manually finish the product transfer, if the product transfer status is

"Completed".

Product transfer aborted

The user may choose to abort the product transfer before the product transfer is completed.

The product transfer can be "Aborted", when the tank is in an "Active" transfer stage.

When the product transfer is aborted, the system does not record the data of starting and ending of product transfer. In such case, the system maintains different sets of data. The data of a previously completed or finished product transfer are preserved, and the data of the aborted product transfer are discarded.

82 Endress+Hauser

Tankvision The Tank Details screen

Observe the following information regarding the product transfer!

• The system displays a pop up message to confirm about the aborting of the product transfer.

• The system generates an event for an aborted product transfer. The event details can be viewed in the Event or Alarm & Event tab.

Error Messages

1. "Tank cannot be armed for product transfer if "No product" has been assigned to tank"

This message appears when the user attempts to create a product transfer when "No

Product" is assigned to the tank.

2. "The Tank status is "Locked", cannot create a new product transfer for a tank that is locked"

This message appears when the user attempts to create a product transfer when the tank status is "Locked".

3. "The Tank status is "In Maintenance", cannot create a new product transfer for a tank that is in maintenance"

This message appears when the user attempts to create a product transfer when the tank status is "In Maintenance".

4. "Batch size cannot be zero, if you do not wish to specify batch size leave the field empty"

This message appears when the Batch size entered by the user is equal to zero.

5. "Batch size should be greater than zero"

This message appears when the value of the Batch size entered by the user is less than zero.

6. "Batch size should be smaller than remaining tank capacity"

This message appears when the transfer type is "In" and the batch size entered by the user is more than the remaining tank capacity.

7. "Batch size should be smaller than available product quantity"

This message appears when the transfer type is "Out" and the batch size entered by the user is more than the available product quantity.

8. "Minimum batch deviation should be less than maximum batch deviation"

This message appears when the Minimum batch deviation entered by the user is greater than or equal to maximum batch deviation.

9. "Pre-alarm percentage should be greater than zero"

This message appears when the Pre-alarm percentage entered by the user is less than or equal to zero.

10. "Pre alarm percentage should be less than minimum batch deviation"

This message appears when the pre-alarm percentage entered by the user is more than the minimum batch deviation.

Endress+Hauser 83

The Tank Details screen Tankvision

8.8

The "Tank Status" tab

The tanks in the Tankvision system are associated with a status which can be changed by the operator.

To change the tank status

1.

Click the Tank Status tab. Tankvision displays the screen as follows:

84

Field

Current Status

Change Status to

Description

The system displays the current status of the tank.

Select the appropriate status type from the drop down list. This field allows you to select the status in which the tank is required to function. The statuses are:

• In Operation: The tank is in normal operation.

• In Maintenance: The tank is under maintenance. A tank is always empty under maintenance, and tank operations such as gauge commands or product transfers cannot be performed. The field scan is not needed.

• Manual: The tank is in operated manually, which means the system will not measure the data automatically. All tank parameters are in manual mode and the field scan is in off mode. A product transfer can occur.

• Locked: The tank is generally filled but locked to disallow product transfer. All other activities can be performed.

Refer to "Tank Status Change Matrix" (→ ä 84) for the activities that can be performed

under various tank statuses, and to "Tank Status Indicator" (→ ä 85) to learn about the

notification on the tank status graph.

2.

3.

4.

Enter the appropriate information in the relevant fields.

Click the Submit button to change the tank status.

After saving the settings, Tankvision displays a confirmation message.

An event is generated after changing the tank status. The event details can be viewed in the Event or Alarm & Event overview.

8.8.1

Tank Status Change Matrix

The activities that can be performed under various tank statuses are as follows:

Activity vs Tank Status

Inventory Calculation

Product Transfer

Gauge Commands

Raise Change in Volume Alarm

Field Scan

Raise Alarms

No

Yes

Yes

In Operation

Yes

Yes

Yes

No

No

No

Manual

Yes

Yes

No

No

No

No

Maintenance

No

No

No

Yes

Yes

Yes

Locked

Yes

No

No

Endress+Hauser

Tankvision The Tank Details screen

8.8.2

Tank Status Indicator

Tankvision indicates the tank status on the Tank Display and Alarm Set Point section in the General Details section. When the tank status is modified to "In Operation", the system indicates the tank status on the Tank Display and Alarm Set Point section as follows:

When the tank status is modified to "In Maintenance", the system indicates the tank status on the Tank Display and Alarm Set Point section as follows:

When the tank status is modified to "Manual", the system indicates the tank status on the

Tank Display and Alarm Set Point section as follows:

Endress+Hauser 85

The Tank Details screen Tankvision

When the tank status is modified to "Locked", the system indicates the tank status on the

Tank Display and Alarm Set Point section as follows:

86 Endress+Hauser

Tankvision The Tank Details screen

8.9

The "Assign Product" tab

After configuring a product, it has to be assigned to a tank. The user can assign only one product to a tank. Before another product can be assigned to the tank, the product currently assigned to the tank must be unassigned. A product which is currently assigned to a tank can not be deleted from the system.

To assign a product to a tank

1.

Click the Assign Product tab. Tankvision displays the screen as follows:

Field

Product

Sediment and Water

Percentage

Description

Select the appropriate product from the drop down list.

This field enables the system to assign a product to a specific tank.

Enter the appropriate sediment and water percentage for the selected product.

The Tankvision system uses the sediment and water percentage in tank inventory calculations and corrects the product volume according to the sediment and water content.

The data type for this field is numeric.

2.

3.

4.

Enter the appropriate information in the relevant fields.

Click the Submit button to assign the product to the tank.

After saving the settings, Tankvision displays a confirmation message.

Observe the following information!

• Once the product is assigned to the tank, the tank is automatically added to the built-in product group, and the tank can be seen in the navigation tree of the screen under the

Products header.

• An event is generated after a product is assigned to a tank. The event details can be viewed in the Event or Alarm & Event overview.

Endress+Hauser 87

The Tank Details screen Tankvision

8.10

The "Product Transfer Report" tab

The Tankvision system allows the user to arm a tank for product transfer, and is set up to detect the start and end of the product transfer details for a tank. The system records the product transfer data and generates a report for the product transfer with "Completed" and

"Finished" statuses, using an appropriate template. You can view or even edit the product transfer report for the last product transfer that has been completed by the system.

To generate a product transfer report

1.

Click the Product Transfer Report tab. Tankvision displays the screen as follows:

88

Field

W&M Approved

Description

This section displays the status of W&M approval.

Configuration Setting

Details

This section displays the report of the configuration settings.

Refer to "Site Information" (→ ä 117) for details.

Product Transfer

Details

Element Name

This section displays the report of Product Transfer settings.

Refer to "Product Transfer Life Cycle" (→ ä 75) for details.

This section displays the result of the product transfer in terms of parameter changes.

Refer to "Tank Calculator" (→ ä 90) for details.

Endress+Hauser

Tankvision The Tank Details screen

Click To

Send an e-mail containing the Product Transfer Report.

Enter the appropriate e-mail address of an authorized person in the adjacent field.

Click the Edit button to edit the Product Transfer Report. When you click the Edit button, the system will display the Product Transfer Report, which is editable. Following fields are editable:

• Product Transfer Details- Batch Size (Volume)

• Element Name- Start Data and End Data of the Product Level, Date (mm/dd/yyyy) and Time (HH:MM:SS AM) fields

After editing the appropriate fields on the editable Product Transfer Report screen, click the Submit button. After saving the settings, Tankvision displays a confirmation message.

An event is generated, while editing the product transfer report.

Obtain a printed copy of the Product Transfer Report.

2.

For more information on the product transfer report, → ä 199.

Endress+Hauser 89

The Tank Details screen Tankvision

8.11

The "Tank Calculator" tab

The Tankvision system performs inventory calculations based on the measured data scanned from a gauge or entered manually. The system uses the tank and product configuration mainly to perform these calculations. Tankvision provides a tank calculator to evaluate various 'what if' scenarios. These scenarios could be:

• What would be the product volume for a certain product level?

• What would be the product level, if a certain quantity of product is pumped into the tank?

• What would be the product volume, if the product level is equal to the high level alarm?

Based on the above mentioned scenarios, the tank calculator would also indicate whether the resulting tank parameter could cause an alarm.

Thus, prior to an actual product transfer, the tank calculator can be used to verify whether it is possible to perform an "out" or "in" product transfer without resulting in an alarm.

Any tank parameter that is changed in the tank calculator is used to carry out calculations and display results to evaluate the what-if scenarios. Changing tank parameters in the tank calculator does not change the actual tank data.

To use the tank calculator

1.

Click the Tank Calculator tab. Tankvision displays the screen as follows:

90

NXA82x_Tank_Tank-Calculator--Tab

Use the scroll bar on the right to see more parameters.

Column

Parameter

Start Value

End Value

Delta Value

Description

This column displays a list of product parameters for which the start and end value can be entered for the purpose of calculation.

Enter the appropriate start values for the relevant parameters in the corresponding text boxes.

The start value is the initial value of the parameter. For example, the initial level of the product will be the start value for Product Level. The data type for this field is numeric.

Enter the appropriate end values for the relevant parameters in the corresponding text boxes.

The end value is the current or final value of parameter. For example, the current or final level of the product will be the end value for Product Level. The data type for this field is numeric.

The delta values are not editable. The delta value is the difference between the start value and the end value of a parameter. The data type for this field is numeric.

2.

Enter the appropriate information in the relevant fields and click the Calculate button.

Endress+Hauser

Tankvision The "Products" menu

9 The "Products" menu

The Tankvision system manages the inventory calculations of various products stored at a tank farm. The system calculates inventory data such as volume, mass, etc., based on the type of product that is present in the tank. In order to do this, the system allows the user to configure the properties of the product in the Configure Products Interface.

9.1

Adding, Modifying and Deleting Products

On the Navigation Tree, click the Products Header. (The number of products configured is displayed in brackets next to the Header’s name.) Tankvision displays the screen as follows:

NXA82x_Product-Overview

To add a product

1.

Select Configure New Products by clicking on the in front. Tankvision displays the screen as follows:

NXA82x_Product-Overview_Configure-New-Products

2.

3.

Enter the Product Name and configure the initial settings, like Product Type and

Calculation Method (API_ASTM or GBT) and click on Submit.

Configure the product details as described in the following sections (→ ä 93).

Observe the following information!

• The product configuration cannot be added while the system is W&M locked and the

W&M switch is closed on the Tankvision unit.

• An event is generated after adding the product details. The event details can be viewed in the Event or Alarm & Event overview.

To modify product details

1.

2.

Open the Product Overview page and select the appropriate <Product Name> to modify the product details.

Click the Modify button. Tankvision displays the screen as follows:

Endress+Hauser

3.

Configure the product details as described in the following sections.

Observe the following information!

NXA82x_Product-Overview_Modify

91

The "Products" menu Tankvision

• The product configuration cannot be modified while the system is W&M locked and the

W&M switch is closed on the Tankvision unit.

• An event is generated after modifying the product details. The event details can be viewed in the Event or Alarm & Event overview.

To delete a product

1.

Select the appropriate <Product Name> to delete the product.

NXA82x_Product-Overview_Modify

2.

Click the Delete button. Tankvision displays the confirmation screen as follows:

NXA82x_Product-Overview_Delete-Product-Message

3.

Click the OK button to delete the selected product.

4.

After saving the settings, Tankvision displays a confirmation message.

An event is generated after deleting the product. The event details can be viewed in the

Event or Alarm & Event overview.

Error Messages

1. "Product Assigned To Respective Tanks"

This message appears when the user tries to delete a product which is assigned to a tank.

92 Endress+Hauser

Tankvision The "Products" menu

9.1.1

General

To configure the general details of the product

1.

On the Navigation Tree, click the Products Header.

2.

Select the appropriate product family by clicking on the in front.

3.

Click on Modify to configure the details of the product. Tankvision displays the screen as follows:

4.

Endress+Hauser

NXA82x_Product-Overview_Modify-Product_General

Field

Product Name

Description

Enter the name of the product. This field displays the name of the product in the tank.

The data type for this field is alphanumeric and can contain a few special characters. In this field, the usage of some of the special characters, such as, '%', '^', '#', '/', '|' and '\' is forbidden.

Product Type

Calculation Method Click this field to select the appropriate calculation method from the drop down list.

API_ASTM: Calculations according API/ASTM standards

GBT: Calculations according GBT standard

Product Safety

Sheet

Product Colour

Click this field to select the appropriate product type from the drop down list.

This field displays the product type. This enables the system to categorize the products into appropriate tables (currently disabled).

Enter the URL for the product safety sheet. The URL can be used to browse to the product safety sheet.

Select the appropriate colour from the colour palette. This field displays the colour chosen to represent the product. The product color is used in tank graphics to depict the product level using a bar graph.

Comments Enter comments related to the product. This field displays comments (if any), with reference to the product. The data type for this field is alphanumeric and can contain all special characters.

5.

6.

7.

Enter the appropriate information in the relevant fields.

Click the Submit button to configure the general details of the product.

After saving the settings, Tankvision displays a confirmation message.

An event is generated after creating or modifying the product. The event details can be viewed in the Event or Alarm & Event overview.

93

The "Products" menu Tankvision

9.1.2

Volume Correction Factor (VCF)

The product volume calculated using the product level is the volume under measuring conditions. If the product is a hydrocarbon, its density and volume change based on the temperature. The product volume needs to be corrected to "volume at standard or reference temperature". This correction is performed by using the Volume Correction Factor (VCF). The

Volume Correction Factor (VCF) screen allows you to view and modify the settings for VCF calculation of the product.

To configure product VCF calculation details

1.

On the Navigation Tree, click the Products Header.

2.

Select the appropriate product family by clicking on the in front.

3.

Click on Modify to configure the details of the product.

4.

94

NXA82x_Product-Overview_Modify-Product_VCF

Field

Range Checking

Description

Select the check box to enable range checking. Clear the check box to disable range checking. The VCF can be calculated from a configured table only, when the input density is within an acceptable range of the table. When the range checking is on, the system does not calculate VCF if the input density is out of range. To allow VCF calculation to proceed for all density values, range checking needs to be switched off.

Perform Input

Rounding

Select the check box to enable input rounding. Clear the check box to disable input rounding.

When the input rounding is enabled, the system performs rounding off input values to the table based on the rounding rules of the table.

Output Rounding Select the appropriate option by clicking on the relevant option. This field allows you to select the appropriate method for rounding of the output values in the VCF calculation.API/

ASTM: This field enables the system to round the input and output values of the inventory calculation in accordance with the API/ASTM standards.No Rounding: This field enables the system to display the output values of the inventory calculation with decimals.Custom:

Select the Custom option, and enter the appropriate number of digits in the adjacent text box.

This field enables the system to round the output values of the inventory calculation to the number of digits as specified in the adjacent text box. You can round the values to between zero to nine digits. The data type for this field is "numeric".

Table for VCF

Calculation

Input Pressure

Select the appropriate table for the VCF calculation from the drop down list. This field allows you to select an appropriate table to calculate the required VCF. Certain tables require additional configuration settings. When any such table is selected, the system displays related input fields. The user needs to enter appropriate values in these additional input fields specific to the respective table.

API 2004 can use the product pressure as additional input to correct the volume. For all other corrections this option is not available and therefore disabled.

5.

6.

7.

Enter the appropriate information in the relevant fields.

Click the Submit button to configure the VCF calculation.

After saving the settings, Tankvision displays a confirmation message.

Observe the following information!

Endress+Hauser

Tankvision The "Products" menu

• Configuring Volume Correction Factor (VCF) is enabled, if General Product

Configuration is completed and saved.

• An event is generated after creating or modifying the product. The event details can be viewed in the Event or Alarm & Event overview.

9.1.3

Reference Density Calculation (RDC)

Similar to the product volume, the product density at the observed temperature needs to be corrected to the standard or reference density. This density is then used to calculate the product mass. The Reference Density Calculation (RDC) screen allows the user to view and modify the settings for RDC calculation of the product.

To configure product RDC calculation details

1.

On the Navigation Tree, click the Products Header.

2.

Select the appropriate product family by clicking on the in front.

3.

Click on Modify to configure the details of the product.

4.

Click follows: on

Endress+Hauser

NXA82x_Product-Overview_Modify-Product_RDC

Field

Table for RDC

Calculation

Range Checking

Perform Input

Rounding

Output Rounding

Density in Air/

Vacuum

Description

Select the appropriate table for RDC calculation from the drop down list. This field allows you to select an appropriate table to calculate the required reference density. Certain tables require additional configuration settings. When any such table is selected, the system displays related input fields. The user needs to enter appropriate values in these additional input fields specific to the respective tables.

Select the check box to enable range checking. Clear the check box to disable range checking.

RDC can be calculated from a configured table only when the input density is within an acceptable range of the table. When the range checking is on, the system does not calculate RDC if the input density is out of range. To allow the RDC calculation to proceed for all density values, range checking needs to be switched off.

Select the check box to enable input rounding. Clear the check box to disable input rounding.

When the input rounding is enabled, the system performs rounding of input values to the table based on the rounding rules of the table.

Select the appropriate option by clicking on the relevant option. This field allows you to select the appropriate method for rounding of the output values in the RDC calculation.API/ASTM: This field enables the system to round the input and output values of the inventory calculation in accordance with the API/ASTM standards.No

Rounding: This field enables the system to display the output values of the inventory calculation with decimals.Custom: Select the "Custom" option, and enter the appropriate number of digits in the adjacent text box.

This field enables the system to round the output values of the inventory calculation to the number of digits as specified in the adjacent text box. You can round the values to between zero to nine digits. The data type for this field is "numeric".

Select if the density refers to atmospheric conditions (in air) or to the vacuum.

95

The "Products" menu Tankvision

Field

Input Temperature

Input Pressure

Reference

Temperature

Description

Either the Product Temperature can be used as an input value for Reference Density calculation or a Sample Temperature (the temperature at which the sample was taken and measured).

API 2004 can use the product pressure as additional input to correct the density. For all other corrections this option is not available and therefore disabled.

Select if the Standard Reference Temperature of 15 °C (60 °F) is used for the RDC

Calculation or an Alternate Temperature.

5.

6.

7.

Enter the appropriate information in the relevant fields.

Click the Submit button to configure the RDC calculation.

After saving the settings, Tankvision displays a confirmation message.

Observe the following information!

• Configuring Reference Density Calculation (RDC) is enabled if General Produkt

Configuration is completed and saved.

• An event is generated after creating or modifying the product. The event details can be viewed in the Event or Alarm & Event overview.

9.1.4

Sediment & Water

The Sediment & Water screen allows you to view and modify the settings for the sediment and water content in the product.

To configure sediment and water details

1.

On the Navigation Tree, click the Products Header.

2.

Select the appropriate product family by clicking on the in front.

3.

Click on Modify to configure the details of the product.

4.

Field

Sediment and Water present

Description

Select the check box to enable other fields on the screen if sediment and water is present in the product. Clear the check box to disable other fields on the screen if sediment and water is not present in the product. This field allows you to configure the amount of sediment and water content in the product. Sediment and Water is a material that coexists with petroleum fluid, but is foreign to a petroleum fluid. This foreign material may include free water and sediment and emulsified or suspended water and sediment.

96 Endress+Hauser

Tankvision The "Products" menu

Field

Sediment and Water

Calculation Method

Description

Select the appropriate sediment and water calculation method from the drop down list.

The Tankvision system uses this field to calculate the sediment and water correction and apply it to the appropriate volume for further calculations. The methods are as follows:

• No S&W Calculation

• CSW Works on TOV:

Correction for Sediment and Water is applied to total observed volume.

• CSW Works on (TOV-FWV):

Correction for Sediment and Water is applied to (Total Observed Volume - Free Water

Volume).

• CSW Works on {(TOV-FWV)*CTSH}:

Correction for Sediment and Water is applied to {(Total Observed Volume - Free Water

Volume) * Tank Shell Correction}.

• CSW Works on {(TOV-FWV)*CTSH}-+FRA:

Correction for Sediment and Water is applied to [[{(Total Observed Volume - Free

Water Volume) * Tank Shell Correction} +- Floating Roof Adjustment].

• CSW Works on GOV:

Correction for Sediment and Water is applied to Gross Observed Volume.

• CSW Works on GSV:

Correction for Sediment and Water is applied to Gross Standard Volume.

5.

6.

7.

Enter the appropriate information in the relevant fields.

Click the Submit button to configure the sediment and water content in the product.

After saving the settings, Tankvision displays a confirmation message.

Observe the following information!

• Configuring Sediment & Water is enabled if General Product Configuration is completed and saved.

• An event is generated after creating or modifying the product. The event details can be viewed in the Events or Alarm & Events overview.

Endress+Hauser 97

The "Products" menu Tankvision

9.1.5

Mass & Weight

The Mass & Weight screen allows you to view and modify the settings for the product mass and weight calculation.

To configure mass calculation details

1.

On the Navigation Tree, click the Products Header.

2.

Select the appropriate product family by clicking on the in front.

3.

Click on Modify to configure the details of the product.

4.

98

Field

Liquid Mass (Mass in vacuum)

Calculation Method

Description

Select the appropriate liquid mass calculation method from the drop down list. The system calculates the product liquid mass (mass in vacuum) using the method configured in this field. The methods are as follows:

• NSV*Reference Density: Calculate mass using Net Standard Volume and Reference density

• GSV*Reference Density: Calculate mass using Gross Standard Volume and Reference density

• GOV*Observed Density: Calculate mass using Gross Observed Volume and Observed density

• GOV*Reference Density: Calculate mass using Gross Observed Volume and Reference density

Automatically

Switchover Mass in

Vacuum

Calculation Method

Select the check box to automatically switchover the mass in the vacuum calculation method.

Clear the check box to prevent automatic switchover of the mass in the vacuum calculation method. RDC or VCF calculation can fail in certain cases (for example, if the input values are out of range, resulting in a "fail" status of the reference density and or standard volume). In this case, the liquid mass cannot be calculated using the reference density and standard volume. If automatic method switchover is enabled, the system will use appropriate methods to calculate the mass using the observed density and observed volume.

Weight (Mass in

Air) Calculation

Method

Vapor Density

Brass Density

Air Density

Select the appropriate weight calculation method from the drop down list. The system calculates the product liquid weight (Mass in air) using the method configured in this field.

If Custom is selected from the drop down list, the system displays the fields Vapor Density,

Brass Density and Air Density.

Enter the value of the vapor density for the product. This field is enabled if the user selects

Custom in the Weight (Mass in Air) Calculation Method field. The value of the vapor density cannot be equal to the brass density. This field is mandatory when the method to calculate the product weight is Custom. The data type for this field is "numeric".

Enter the value of brass density for the product. This field is enabled if the user selects

Custom in the Weight (Mass in Air) Calculation Method field. The value of the brass density cannot be equal to the vapor density or 0 (zero). This field is mandatory when the method to calculate the product weight is Custom. The data type for this field is "numeric".

Enter the value of air density for the product. This field is enabled if the user selects Custom from the Weight (Mass in Air) Calculation Method field. This field is mandatory when the method to calculate the product weight is Custom. The data type for this field is numeric.

5.

6.

Enter the appropriate information in the relevant fields.

Click the Submit button to configure the product mass and weight calculation.

Endress+Hauser

Tankvision The "Products" menu

7.

After saving the settings, Tankvision displays a confirmation message.

Observe the following information!

• Configuring Mass & Weight is enabled if General Product Configuration is completed and saved.

• An event is generated after creating or modifying the product. The event details can be viewed in the Event or Alarm & Event overview.

9.1.6

Vapor Calculation

The Vapor Calculation screen allows you to view and modify the Vapor settings of the product.

3.

4.

1.

2.

On the Navigation Tree, click the Products Header.

Select the appropriate product family by clicking on the in front.

Click on Modify to configure the details of the product.

NXA82x_Product-Overview_Modify-Product_Vapour-Calculation

Field Description

Vapor Mass Calculation Defines the calculation of the Vapor Mass: Vapor Density Mode, Equivalent Method

5.

Configure the product details as descriped in the following sections.

Vapor Mass Calculation

Endress+Hauser

NXA82x_Product-Overview_Modify-Product_Vapour-Mass-Calculation

Field

Vapor Calculation

Method

Range Checking

Description

Allows to configure the vapor calculation method.

Perform the range checking for the input variables according to the standard allowed range values.

Perform input rounding according to the method defined rounding criteria.

Perform Input

Rounding

Output Rounding

Molecular mass of vapour

Compressibility

Define if an output rounding has to be applied. In custom mode a configuration box allows to enter a rounding value.

Define the molecular mass of the vapour.

Define the compressibility of the vapour.

99

The "Products" menu Tankvision

9.1.7

Advanced (Weight & Measure)

The Advanced (Weight & Measure) screen allows you to view and modify the advanced weight and measures settings of the product.

To configure product W&M settings

1.

On the Navigation Tree, click the Products Header.

2.

Select the appropriate product family by clicking on the in front.

3.

Click on Modify to configure the details of the product.

4.

Field

Product

Configuration

Resides Under W&M

Switch

Manual Status of VCF does not Propagate

Description

When this check box is selected, the product configuration can be protected for W&M aspects, and the product configuration cannot be modified when the W&M switch has been closed.

Last Valid Status

(Density,

Temperature &

Water) does not

Propagate

Manual Status of

Density does not

Propagate

Select this check box, if the system should not propagate the manual status of the VCF to obtain the standard volume. Clear the check box to enable the system to ensure that the manual status of the VCF propagates to obtain the standard volume.

Select this check box to disallow the system to use the values of the last valid status for density, temperature and water in subsequent calculations. The user may select this field when the current values for density, temperature and water are available.

Clear the check box to allow the system to use the values of the last valid status for density, temperature and water, in subsequent calculations. The user may clear this field when the current values for density, temperature and water are not available.

Select the check box to disallow the system from using the values of the manual status of the density in the subsequent calculations. Clear the check box to allow the system to use the values of the manual status of the density in the subsequent calculations.

5.

6.

7.

Enter the appropriate information in the relevant fields.

Click the Submit button to configure the advanced weight and measures settings.

After saving the settings, Tankvision displays a confirmation message.

Observe the following information!

• Advanced (Weight and Measures) is enabled, if General has been configured.

• An event is generated after creating or modifying the product. The event details can be viewed in the Event or Alarm & Event overview.

100 Endress+Hauser

Tankvision The "Products" menu

9.2

View Product Tank Groups

The Tankvision system has a product-tank group feature, where the user can view different products stored in various tanks.

To view the product-tank group

1.

On the Navigation Tree, click the Products Header. (The number of products configured is displayed in brackets next to the Header’s name.) The Products header expands as follows:

Endress+Hauser

NXA82x_Menu_Products

2.

3.

In the above figure, the <Product Types> created by the authorized personnel are displayed under the Products header. Below the <Product Types> the <Product Name> is displayed. The number shown inside the bracket is the total number of tanks that contain the product.

Click the <Product Name> to display the tanks filled with the relevant product.

Tankvision displays the screen as follows:

4.

By default, the system displays the tabular view of the product group in the Products-

<Product Name> screen.

Click the , the system will expand the node and display the names of the tanks that have this product. The user may click on the <Tank Name> to view the detailed information about the tank.

101

The "Products" menu Tankvision

9.2.1

Graphical View of the Product-Tank Group Details

To view the product-tank group details in graphical format

On the Products - <Product Name> screen, click the Graphical View tab. Tankvision displays the screen as follows:

NXA82x_Product-Tank-Groups_Graphical-View

Field

<Tank Name> und

<Product Name>

Level of Alarm

Graphical Bar

Product Parameter

Description

The tank names and the product names are displayed for the selected tank group.

The current level of alarm is displayed as per the alarm set point.

The graphical bar displays the product level and water level.

Each tank’s measured data, viz., product level and product temperature are displayed with the appropriate units. The system also indicates the alarm acknowledgement status using different background colors. The background colors are as follows:

• Dark green - indicates an active and acknowledged alarm

• Light red - indicates an active and unacknowledged alarm

• Yellow - indicates an inactive and unacknowledged alarm

• White - indicates an inactive and acknowledge alarm

The total number of tanks in a tank group is displayed as per the tank group parameter.

Tanks in a Tank group

"??" No alarm set points are configured.

The green mark in the upper right hand corner of a graphical tank picture, shows the alive status of the Java applet. If the applet does not receive any data, the mark will change from green to red.

A guest user can view the Non Real Time Product-Tank Group Details screen. The system displays the measured graphical information of the tanks, when the <Product

Name> is selected. The user has to manually refresh the screen to view the latest measured graphical information.

102 Endress+Hauser

Tankvision The "Products" menu

9.2.2

Tabular View of the Product-Tank Group Details

To view the product-tank group details in tabular format

On the Products - <Product Name> screen, click the Tabular View tab. Tankvision displays the screen as follows:

Description of the screen:

1. Displayed columns are selectable (see: to add columns to the tabular view):

Tank name, Product, Tank Status, Tank Shape, Movement Direction, Product Level,

Level Alarms, Water Level, Observed Density, Vapor Temperature, Vapor Pressure,

TOV, Product Temperature, Free Water Volume (FWV), Gross Observed Volume (GOV),

Gross Standard Volume (GSV), Net Standard Volume (NSV), Floating Roof Status, Total

Mass, Dipped Product Level, Dipped Water Level, Dipped Temperature, Dipped

Observed Density, Unit Alive Status, Total Observed Volume Flow Rate, Net Standard

Volume Flow Rate, Total Mass Flow Rate, Total Standard Volume, Remaining Tank

Capacity, Available Volume, Reference Density, Net Weight in Air, Alcohol Content By

Mass, Alcohol Content By Volume, Sample Temperature.

2. Description of the colours:

– Brown: indicates that the level is moving up

– Blue: indicates that the level is moving down

A guest user can view the Non Real Time Product-Tank Group Details screen. The system displays the measured tabular information of the tanks, when the <Product

Name> is selected. The user has to manually refresh the screen to view the latest measured tabular information.

To add columns to the tabular view

1.

Right-click in the grey area outside the table. The following pop-up window appears:

Endress+Hauser

NXA82x_Products_Tabular-View_Pop-Up

2.

3.

Select/deselect the columns you want to see/don’t want to see.

"+" possibility to enlarge, "-" possibility to minimize, by default on the smallest scale.

103

The "Products" menu

4.

The tabular view will show the selected values until further changes.

Tankvision

104 Endress+Hauser

Tankvision The "Customized Groups" menu

10 The "Customized Groups" menu

A tank group is a collection of tanks. In the Tankvision system, tank groups are configured for better management of tanks. There are two types of tank groups:

• Static Tank Group: A static tank group is created by selecting tanks available in the system.

For a static tank group, the user must select the appropriate tanks available to form a tank group. All selected tanks in a particular static tank group will be displayed on the screen.

The screen will display the tank data dynamically on a real time basis.

• Dynamic Tank Group: A dynamic tank group is created by defining filtration criteria. For a dynamic tank group the user does not select the tanks. Instead, the user can define selection criteria using filters on tank elements such as Product, Location, Tank Type and

Tank Status. The screen will display the tank data dynamically on a real time basis for those tanks in the tank group meeting the dynamic tank group settings. For example, if a tank group is configured with active alarms, then whenever the tank has an active alarm, the tank will be shown in the tank group with active alarms.

To configure tank groups

1.

On the Navigation Tree, click the Customized Groups header. (The number of tank groups configured is displayed in brackets next to the Header’s name).

Tankvision displays the screen as follows:

2.

Click the New Static Group button to configure a static type of tank group, or click the

New Dynamic Group to configure a dynamic type of tank group.

Endress+Hauser 105

The "Customized Groups" menu Tankvision

10.1

Static Tank Group

To configure a static type of tank group

1.

Click the New Static Group button on the Manage Customized Groups screen.

Tankvision displays the Add Static Group screen as follows:

Field

Tank Group Name

Available Tanks

Selected Tanks

Description

Enter the name of the Tank Group. Each tank group in the Tankvision system has a specific name for reference which should not exceed 32 characters in length.

The data type for this field is alphanumeric.

This list displays the tanks that are available for grouping.

This list displays the tanks that are grouped to the tank group.

Click this button to transfer the selected tank(s) from the Available Tanks list to the

Selected Tanks list. (Several tanks can be selected by holding the Ctrl button with clicking on the tanks)

Click this button to transfer all tanks from the Available Tanks list to the Selected

Tanks list.

Click this button to de-select the tank(s) from the Selected Tanks list to the Available

Tanks list. (Several tanks can be selected by holding the Ctrl button with clicking on the tanks)

Click this button to de-select all tanks from the Selected Tanks list to the Available

Tanks list.

2.

3.

Enter the appropriate information in the relevant fields.

Click the Submit button to add a static tank group. After saving the settings, Tankvision displays a confirmation message as follows:

106

4.

Click Manage Groups to get back to the customized groups overview without saving.

An event is generated after successfully adding, modifying or deleting the tank group.

The event details can be viewed in the Event or Alarm & Event overview.

Endress+Hauser

Tankvision The "Customized Groups" menu

10.2

Dynamic Tank Group

To configure a dynamic tank group

1.

Click the New Dynamic Group button on the Manage Customized Groups screen.

Tankvision displays the Add Dynamic Group screen as follows:

Field

Tank Group Name

Criteria

Description

Enter the appropriate name of the Tank Group. Each tank group in the Tankvision system has a specific name for reference, which should not exceed 32 characters in length.

The data type for this field is alphanumeric.

Select the appropriate option to filter the criteria:

• Select the relevant tank elements from the drop down list in the first column.

• Select the appropriate comparable option (Equals, Not Equals or Contains) from the drop down list in the second column.

• Type the appropriate data element in the third column, if Location or Product is selected. Or, select the appropriate data element from the drop down list, if Tank Type or Tanks Status is selected in the first column of selection criteria.

• If two criteria are to be specified, then select the And or Or option to add a filtration criterion. Else, select the None option.

2.

3.

Enter the appropriate information in the relevant fields.

Click the Submit button to add the dynamic tank group. After saving the settings,

Tankvision displays a confirmation message as follows:

An event is generated after successfully adding, modifying or deleting the tank group.

The event details can be viewed in the Event or Alarm & Event overview.

Endress+Hauser 107

The "Customized Groups" menu Tankvision

10.3

Modify Tank Groups

1.

On the Navigation Tree, click the Customized Groups header. (The number of tank groups configured is displayed in brackets next to the Header’s name). Tankvision displays the screen as follows:

2.

To modify tank groups click the button Modify. Tankvision displays the screen as follows:

3.

4.

Modify the desired settings and click the Submit button to configure the settings.

After saving the settings, Tankvision displays the following screen:

108 Endress+Hauser

Tankvision The "Customized Groups" menu

10.4

Delete Tank Groups

1.

On the Navigation Tree, click the Customized Groups header. (The number of tank groups configured is displayed in brackets next to the Header’s name). Tankvision displays the screen as follows:

2.

To delete tank groups click the button Delete. Tankvision displays the screen as follows:

3.

After deleting the Tank Group, Tankvision displays the following screen:

Endress+Hauser 109

The "Customized Groups" menu Tankvision

10.5

View Real Time Tank Group Details

The user can select a tank group from the navigation menu, and can view the tank group details in graphical and tabular format. The graphical and tabular format give a quick feedback about the current tank status. The screen displays the tank data dynamically on a real time basis. The graphical and tabular page shows the tanks in the selected tank group.

Each tank is shown with its tank parameters. There are two types of Tank Groups:

1. Static Tank Group: Tank group created by user

2. Dynamic Tank Group: Tank group created by defining filtration criteria. (e.g. All tanks in locked status)

Both types of tank groups are supported with real time graphical information.

The tank group details are viewed by two types of users, viz. operator and guest. The user logging into the system as an operator can view the real time tank group details. The user logging into the system as a guest can view the non-real time tank group details. A guest user has a minimal access to the Tankvision functionality. A guest user can view the tank details, gauge details, tank group and tank overview (all tanks on a specific Tankvision unit) in a non-real time mode. The guest user has to refresh the page to view the current tank data.

To view real time tank group details

1.

On the Navigation Tree, click the Customized Groups header. (The number of tank groups configured is displayed in brackets next to the header’s name) The Customized

Groups header expands as follows:

2.

3.

In the above figure, the <Tank Group(s)> name created by the authorized personnel is displayed under the Customized Groups. The number of tanks associated in that group is displayed inside the bracket.

Click the <Tank Group> name to display the tank status in graphical and tabular format.

Tankvision displays the screen as follows:

110

4.

By default, the system displays the tabular view of the tank group.

Endress+Hauser

Tankvision The "Customized Groups" menu

10.5.1 Graphical View of the Tank Group Details

To view the tank group details in graphical format

1.

On the Customized Groups - <Tank Group> name screen, click the Graphical View tab.

Tankvision displays the screen as follows:

1 2 3 4

Endress+Hauser

5

NXA82x_Tank-Group-Details_Graphical-View_Description

2

3

Pos.

Graphical Information Description

1 <Tank Name> and

<Product Name>

The tank names and the product names are displayed for the selected tank group.

4

Graphical Bar

Level of Alarm

Product Parameter

The graphical bar displays the product level and water level.

The current level of alarm is displayed as per the alarm set points.

5 Tanks in a Tank group

Each tank"s measured data, viz., product level and product temperature are displayed with the appropriate units. The system also indicates the alarm acknowledgement status using different background colors. The background colors are as follows:

• Dark green- indicates an active and acknowledged alarm

• Light red- indicates an active and unacknowledged alarm

• Yellow- indicates an inactive and unacknowledged alarm

• White- indicates an inactive and acknowledged alarm

The total number of tanks in a tank group is displayed as per the tank group parameter.

Depending on the tank group type the graphical information is as follows:

Tank Group Type

Static Tank Group

Graphical Information

The system displays the measured graphical information of the tanks at the time of selecting the relevant tank group. The user has to manually refresh the screen to update the latest measured graphical information.

111

The "Customized Groups" menu Tankvision

Tank Group Type

Dynamic Tank Group

Graphical Information

The user can view the measured graphical information of the tanks, which will be shown dynamically on the web page. The user can view the information on a real time basis.

1. In case, a product transfer is taking place under a dynamic tank group, the tank will be shown under (a) the "Tanks in Armed" tank group, if the user has created a new product transfer for a tank, or (b) the "Tanks in Transfer" tank group, if the status of product transfer is changed to "Active" from the "Armed" stage.

2. If the tank group is customized, then the tanks will be displayed in the tank group based on the filtration criteria that have been configured. For example, if

Alarm Type is selected as High Alarm in the Add New Dynamic Tank Group screen, then the tank group will display only those tanks with High Alarm on the Real Time Tank Group screen.

10.5.2 Tabular View of the Tank Group Details

To view the tank group details in tabular format

On the Customized Groups - <Tank Group> name screen, click the Tabular View tab.

Tankvision displays the screen as follows:

No. Graphical Information Description

1 Tank Name (N/A)

No. Graphical Information Description

The column displays the name of the tank. 22 Dipped Temperature This column displays the dipped temperature.

2 Product (N/A) This column displays the name of the product, which is assigned to the corresponding tank.

23 Dipped Observed

Density

This column displays the dipped observed density.

3 Tank Status (N/A)

4

5

6

7

8

9

10

11

Tank Shape

Movement Direction

Product Level

Level Alarms

Water Level

Observed Density

Vapor Temperature

Vapor Pressure

This column displays the status of the tank.

This column displays the shape of the tank.

24

25

Unit Alive Status

TOV Flow Rate

This column displays the Unit Alive Status.

This column displays the TOV flow rate.

This column displays the movement direction.

This column displays the product level measured by the tank.

This column displays the product level alarm.

This column displays the water level in tank.

26

27

28

NSV Flow Rate

Total Mass Flow Rate

29 Remaining tank capacity

30 Available Volume This column displays the observed density of the product in the tank.

This column displays the vapor temperature.

31 Reference density

This column displays the vapor pressure.

32 Net weight in air

This column displays the NSV flow rate.

This column displays the total mass flow rate.

Total Standard Volume This column displays the total standard volume.

This column displays the remaining tank capacity.

This column displays the available volume.

This column displays the reference density.

This column displays the net weight in air.

112 Endress+Hauser

Tankvision The "Customized Groups" menu

No. Graphical Information Description

12 TOV This column displays the Total Observed

Volume (TOV).

13 Product Temperature

14 FWV

This column displays the temperature of the product in the tank.

This column displays the free water volume (FWV).

15 GOV

16

17

18

GSV

NSV

Floating Roof Status

This column displays the Gross Observed

Volume (GOV).

This column displays the gross standard volume (GSV).

This column displays the net standard volume (NSV).

This column displays the floating roof details of the tank.

19 Total Mass

20

21

Dipped Product Level

Dipped Water Level

No. Graphical Information Description

33 Alcohol Content By

Mass

34 Alcohol Content By

Volume

35 Sample Temperature

36

37

38

39

Pressure

Percentage Level

Secondary Level

Gauge Error

This column displays the total mass of the tank.

40 Gauge Status

41 Analog Input This column displays the dipped product level.

This column displays the dipped water level.

This column displays the alcohol content by mass.

This column displays the alcohol content by volume.

This column displays the sample temperature.

This column displays the pressure.

This column displays the percentage level.

This column displays the secondary level.

This column displays gauge errors.

This column displays the gauge status.

This column displays the analog input.

The behavioral pattern of the tank group type is as follows:

Tank Group Type

Static Tank Group

Graphical Information

The system displays the measured information of the tanks at the time of selecting the relevant tank group.

Dynamic Tank Group The user can view the measured information of the tanks, which will be shown dynamically on the web page.

1. In case a product transfer is taking place under a dynamic tank group, the tank will be shown under (a) the Tanks in Armed tank group, if the user has created a new product transfer for a tank, or (b) the Tanks in Transfer tank group, if the status of product transfer is changed to "Active" from the "Armed" stage.

2. If the tank group is customized, then the tanks will be displayed in the tank group based on the filtration criteria that have been configured. For example, if Alarm

Type is selected as High Alarm in the Add New Dynamic Tank Group screen, then the tank group will display only those tanks with High Alarm on the Real Time

Tank Group screen.

The Non Real Time Tank Group Details screen can be viewed by the user who is a guest. The system displays the measured information of the tanks at the time of selecting the relevant tank group. The user has to manually refresh the screen to view the latest measured graphical information.

Endress+Hauser 113

The "Transfers" menu Tankvision

11 The "Transfers" menu

The Tankvision system has a feature of dynamically displaying the product transfer. The product transfer details are grouped in the Waiting, In Progress, Finished, and Aborted product transfer stages. The following table describes the product transfer groups.

Product Transfer Group Product Transfer Status

Waiting In this group, the user can view all the tanks that have a product transfer in the

Armed stage.

In Progress

Finished

In this group, the user can view all the tanks that have a product transfer in the Active and Paused stages.

In this group, the user can view all the tanks that have a product transfer in the

Finished or Completed stages.

Aborted In this group, the user can view all the tanks that have a product transfer in the

Aborted stage.

To view product transfer details

1.

On the Navigation Tree, click the Transfers header. (The number of product transfer groups is displayed in bracket next to the header’s name.) The Transfers header expands as follows:

NXA82x_Menu_Transfers

2.

3.

In the above figure, the <Product Transfer Groups> name are displayed under the

Transfers header. The <Product Transfer Group> name dynamically displays the number of tanks associated with the <Product Transfer Group> name, which is shown inside the bracket.

Click the <Product Transfer Group> name. Tankvision displays the Transfers - <Product

Transfer Group Name> screen as follows:

114

4.

By default, the system displays the tabular view of the product transfer group.

Endress+Hauser

Tankvision The "Transfers" menu

Click the next to the <Product Transfer Group> name. The system will expand the leaf node, and display the <Tank Names> that are in the respective product transfer group. The user may click on the <Tank Name> to view detailed information for the tank.

11.1

Graphical View of the Product Transfer Group Details

To view the product transfer group details in graphical format

On the Transfers - <Product Transfer Group Name> screen, click the Graphical View tab.

Tankvision displays the screen as follows:

Endress+Hauser

The user, who is a guest can view the Non Real Time Product Transfer Group Details screen. The system displays the measured graphical information of the tanks at the time of selecting the relevant product transfer group. The user has to manually refresh the screen to view the latest measured graphical information.

11.2

Tabular View of the Product Transfer Group Details

To view the product transfer group details in tabular format

On the Transfers - <Product Transfer Group Name> screen, click the Tabular View tab.

Tankvision displays the screen as follows:

The user, who is a guest can view the Non Real Time Product Transfer Group Details screen. The system displays the measured graphical information of the tanks at the time of selecting the relevant product transfer group. The user has to manually refresh the screen to view the latest measured graphical information.

115

The "System" menu Tankvision

12 The "System" menu

The user should have access rights to configure the system settings. If the user is accessing the web page without valid access rights, then the system will not allow the user to configure the system settings.

To configure the system settings

1.

In the Navigation Tree, click the System header. It expands as follows:

2.

Click Global Settings. Tankvision displays the screen as follows:

NXA82x_Menu_System

116

NXA82x_Global-Settings-Screen

Endress+Hauser

Tankvision

12.1

Customer Settings

To Configure Global Customer Settings

Click

The "System" menu

Endress+Hauser

12.1.1 Site Information

"Site" refers to the location, where the Tankvision system is installed. The user can configure the site settings in this section.

To configure the site information

1.

Click follows: on

NXA82x_Global-Settings_Customer-Settings_Site-Information

Field

Customer Name

Site Name

Site Location

Graphical Site Map

Customer Logo

Description

Enter the name of your company or customer.

Enter the name of the site, where the Tankvision system is being installed.

Enter the location name of the site, where the Tankvision system is being installed.

Enter the URL to a graphical site map web page, which contains a tank site map.

Click the UPLOAD button to select the appropriate customer's company logo.

The image size must not exceed 32x32 Pixels.

The file name for this field can be alphanumeric.

For more information, see chapter "Upload Customer Logo" (→ ä 118).

2.

3.

4.

Enter the appropriate information in the relevant fields.

Click the Submit button.

After saving the settings, Tankvision displays a confirmation message.

An event is generated after the configuration of the site information. The event details can be viewed in the Event or Alarm & Event overview.

117

The "System" menu Tankvision

Upload Customer Logo

1.

Click the "Upload" button on the "Site Information" screen. Tankvision displays the screen as follows:

Field

Upload File

Description

Enter the location from where you want to upload the file, or click the "Browse" button and select the location.

2.

Click the Send button to proceed, or click the Cancel button to exit. Tankvision displays the uploaded logo and the file name on the Site Information screen as follows:

NXA82x_Global-Settings_Customer-Settings_Site-Information

3.

Click the Submit button. Tankvision displays the new logo on the System Header of the

Tankvision screen.

118 Endress+Hauser

Tankvision The "System" menu

12.1.2 Units

The Tankvision system displays various inventory data or parameters. Each parameter has a specific unit of measurement. The units can be configured to suite the customer requirements. The Tankvision system comes with three standard schemes for units - SI, US and Japanese. Based on the scheme, appropriate units are pre-selected for different physical quantities or parameters. When a scheme is customized, it is indicated with the suffix

'Customised' next to the scheme. Only a user with valid access rights (for example, supervisor/ technician) can change the units setting.

To configure units

1.

Field

SI (default)

US

JAPAN

Description

The SI scheme chooses units based on International System of Units (SI).

The US scheme chooses units, which are prevalent in USA, viz. mm, deg F, gallons, etc.

The Japanese scheme chooses units, which are prevalent in Japan, viz. mm, g/ml, kilo liter, etc.

4.

5.

2.

3.

Select the appropriate unit scheme option.

Click the Submit button to proceed, or click the Advanced button to set up the advanced unit configuration. Tankvision displays a confirmation screen.

Click the OK button to save the details.

After saving the settings, Tankvision displays a confirmation message.

An event is generated after configuring the unit settings. The event details can be viewed in the Event or Alarm & Event overview.

Endress+Hauser 119

The "System" menu Tankvision

Advanced Units Configuration

1.

Click the Advanced button on the Units screen. Tankvision displays the screen as follows:

120

NXA82x_Units

Field Description

Current Unit Scheme Displays the name of the current unit scheme.

Decimal Separator Select the appropriate decimal separator from the drop-down list. For approved systems in Germany (PTB) the decimal separator must be a comma and the thousands separator none, dot or space (no comma, no quote).

Thousands Separator Select the appropriate thousands separator from the drop-down list. For approved systems in Germany (PTB) the decimal separator must be a comma and the thousands separator none, dot or space (no comma, no quote).

Display Sign

Display Leading

Zeroes

Select this check box to display the sign (+) or (-) before each number.

Select this check box to enable the Leading Digits column.

Clear the check box to disable the Leading Digits column.

Column Description

Tank Parameter Type This column displays the types of tank parameters that can be configured for the

Tankvision system.

Unit Select the appropriate unit from the drop-down list. The drop-down lists provide a list of units corresponding to each tank parameter type.

Leading Digits

Decimals

Select or enter the number of leading digits. This field is enabled if the Display Leading

Zeros check box is selected. This option allows the user to set the number of digits for every tank parameter type. If necessary, leading zeros are added to the number. The number of leading digits should not exceed 10.

Select or enter the number of decimal digits. This field allows you to set the number of digits after the decimal separator for every tank parameter type. The number of decimals should not exceed 10.

2.

3.

Enter the appropriate information in the relevant fields.

Click the

–Done button to save the details.

–Reset To Default button to apply the default settings of the system.

–Cancel button to exit the screen without accepting the changes.

Tankvision displays the Units screen.

Endress+Hauser

Tankvision The "System" menu

4.

5.

6.

Click the Done button to save the changes in the Units configuration. Tankvision displays a confirmation screen.

Click the OK button to save the details.

After saving the settings, Tankvision displays a confirmation message.

If you change the default settings for a specific unit scheme, the system displays

Customized next to the unit scheme name on the Units screen.

12.1.3 Default Language

Tankvision provides a multi-lingual interface. The user can set the language according to the local requirements.

To configure the default language

1.

2.

Tankvision displays the Default Language screen as follows:

Field

Default Language

Description

This field displays a list of the languages that have already been configured to be used in the Tankvision interface.

3.

4.

5.

Select the appropriate language from the drop-down list.

Click the Submit button to proceed.

After saving the settings, Tankvision displays a confirmation message.

Endress+Hauser 121

The "System" menu Tankvision

12.1.4 Email Server Settings

The Tankvision system sends e-mails using a standard SMTP server, called the e-mail server.

The Tankvision system sends information about the alarm and event notifications, and other reports to the authorized user by e-mail.

If the system fails to send the e-mail, then the e-mail status in the Alarm and Event Panel section will be "Fail".

To configure the e-mail server

1.

NXA82x_Global-Settings_Customer-Settings_Email-Server-Settings

Field

SMTP Server Name

Description

Enter the appropriate host name or the IP address of the SMTP server. The

Tankvision system uses the SMTP server name to send e-mails. The data type for this field is alphanumeric.

SMTP Server Port Number Enter the appropriate port number of the SMTP server.

The data type for this field is numeric. The default SMTP Server Port number is 25.

"From" E-mail Address Enter the e-mail address that will be used as sender.

The data type for this field is alphanumeric. This entry is mandatory.

Display Name

SMTP Server Requires

Authentication

User Name

Enter the Display Name of the sender. By default, the Display Name is

TankvisionAdmin. The data type for this field is alphanumeric.

Select this check box, if the SMTP server requires an authentication. This will enable the user name and password fields.

Enter the unique user name. This is the user name for SMTP server authentication.

The data type is alphanumeric and is case sensitive.

Enter the password. This is the password for SMTP server authentication.

Password

Test E-Mail Address (To): Enter an E-Mail address to test the E-Mail settings. When clicking the Test

Connection button, a test E-Mail is sent to the address defined in this field.

2.

3.

4.

Enter the appropriate information in the relevant fields.

Click the Submit button to proceed, or click the Test Connection button to test the connection to the e-mail server.

After saving the settings, Tankvision displays a confirmation message.

An event is generated after configuring the E-Mail Server. The event details can be viewed in the Event or Alarm & Event overview.

Email server settings can usually be requested from the Network administration.

122 Endress+Hauser

Tankvision The "System" menu

12.1.5 Date and Time

The system allows the user to configure date, time, time zone and the date-time formats.

The Tankvision system unit, which is configured as a Subscription Store, becomes a time server for other units subscribed to it for global configuration data.

To Configure Date and Time Settings

1.

Endress+Hauser

NXA82x_Global-Settings_Customer-Settings_Date-and-Time

Field

Date Format

Time Format

Time Zone

System Date

System Time

Daylight Saving

Enabled

Daylight Saving

Status

Description

Select the date format from the drop down list. This field allows you to set the required format for the date. This date format will be used to display the date on all Tankvision screens, reports, e-mails and prints.

Select the time format from the drop down list. This field allows you to set the required format for the time. This time format will be used to display the time on all the

Tankvision screens.

Select the appropriate time zone from the drop-down list.

Enter the current date in the relevant date format. Alternatively, click on the calendar icon to choose the date.

Enter the current time in the relevant time format.

Select this check box to enable the user to enter the appropriate daylight saving details.

Clear the check box to prevent the user from entering the daylight saving details.

This field displays the daylight saving status. The system displays the ACTIVE status, if the Daylight Saving Enabled check box is selected.

2.

3.

4.

Enter the appropriate information in the relevant fields.

Click the Submit button.

After saving the settings, Tankvision displays a confirmation message.

An event is generated after configuring Date and Time. The event details can be viewed in the Event or Alarm & Event overview.

12.1.6 Configuration Store definition

In a typical Tankvision system, most configuration settings are common for all Tankvision units within the network. Therefore, the time required for the configuration of the system can be minimized by defining one of the units to be a Subscription Store. The configuration settings are only performed on this Subscription Store. These settings are then distributed to the other units within the network.

For each Tankvision unit (i.e. Tank Scanner NXA820, Data Concentrator NXA821 or Host

Link NXA822) within the network it is necessary to define if it is a Subscription Store or if it receives its configuration from a Subscription Store.

To do so, proceed as follows:

1.

Login to the Tankvision unit and navigate to the Global Settings screen as described in

Section 12.1. Click on Customer Settings.

2.

Click follows: on

123

The "System" menu Tankvision

NXA82x_Define-Configuration-Store-Details

3.

For the Subscription Store:

– In Configuration Store Type select the option Subscription Store (Default)

For the other units

– In Configuration Store Type select the option Use Global Configuration Store

– In Subscription Store select the Subscription Store to which this unit is to be linked

4.

5.

Click the Submit button to proceed, or click the Refresh button to reset the screen.

After saving the settings, Tankvision displays a confirmation message.

With the (recommended) use of global configuration store the following information is transfered to the subscription units:

• Customer settings like site information (without customer specific logo), unit, email server and day and time settings (configurations of languages and printer agent must be done for every single device)

• Environment settings

• Products

• Users incl. user access rights

Global settings could be changed later on, also after assigning other units. Its highly recommended to use a NXA820 as subscription store.

124 Endress+Hauser

Tankvision The "System" menu

12.1.7 Define Configuration Store Details

The Tankvision system is a distributed system, which comprises several Tankvision units working together in a single network. The configuration for most of these units is common.

Hence, these configuration settings are performed in one single Tankvision unit, which acts as a subscription store. A subscription store minimizes the time taken for configuration and avoids any duplication of activity in the Tankvision system. It circulates its configuration to other Tankvision units in the form of Global Settings. Sometimes, a Tankvision unit might need to use global configuration settings that are different from the subscription store. In this case, the Tankvision unit’s settings can be configured by using a local configuration, so that it neither affects nor is affected by the subscription store.

To define configuration store details

1.

Click follows: on

Endress+Hauser

NXA82x_Define-Configuration-Store-Details

Field

Configuration Store

Type

Description

Click the appropriate option to select the relevant configuration store type for this

Tankvision unit.

Subscription Store: This option configures the NXA unit to act as "Global Subscription

Store". Other units can subscribe to this subscription store to get the global configuration.

Any part of the global configuration changed on the subscription store is also updated on the subscribing units and vice versa.

Use Global Configuration Store: This option enables the NXA unit to use an existing

Subscription Store for global configuration. If the system is configured to use the global configuration store, the unit subscribes to the global subscription store to receive any configuration changes.

Use Local Configuration Store: This option enables the NXA unit to use the local configuration, which is different from that of the global subscription store. Any global configuration changed on the global subscription store does not affect the NXA unit configured to use local configuration store and vice versa. The configuration is not accessable for other units (unlike the subscription store).

Subscription Store Select the appropriate subscription store. This field is used to refer to a subscription store when the Tankvision unit is configured to use a global configuration store. This field is enabled only if the Use Global Configuration Store option is selected. This field displays a list of the Tankvision units configured as a subscription store. To get the latest list of global subscription stores, click the Refresh button.

2.

3.

4.

When the subscription store becomes active in the network, the global configuration settings at the subscription store overwrite the global configuration settings on all other Tankvision units. Thus, any changes made to the global configuration locally will be lost.

Enter the appropriate information in the relevant fields.

Click the Submit button to proceed, or click the Refresh button to reset the screen.

After saving the settings, Tankvision displays a confirmation message.

An event is generated after configuring the Subscription Store. The event details can be viewed in the Event or Alarm & Event overview.

12.1.8 Printer Agent Configuration

Tankvision can generate scheduled tank reports which can be printed via a printer without human intervention. This task is performed by the Printer Agent, which can be uploaded to

125

The "System" menu Tankvision

the operator station from any Tankvision unit (→ ä 194). When the Printer Agent has been

installed, it can be configured as follows.

To configure the Printer Agent

1.

Field

Printer Agent IP Address

Port number

Description

Enter the IP address of the computer on which the Printer Agent is installed.

Enter the port of the computer that the printer agent is listening (waiting). For details refer to the DOC-filed contained in the printer agent folder.

2.

3.

4.

Enter the appropriate information in the relevant fields.

Click the Submit button to proceed.

After saving the settings, Tankvision displays a confirmation message.

An event is generated after configuring the Printer Agent. The event details can be viewed in the Event or Alarm & Event overview.

126 Endress+Hauser

Tankvision The "System" menu

12.1.9 Additional Language Configuration

• Download of one additional language pack (beside the pre installed one(s)).

• Type in the location or use the Browse button.

• Download to Tankvision by clicking on Download button.

• The additional language is shown in the meta data header.

• Can be selected as default language ("Default Language", → ä 121) or as based language

("Base Language Configuration", → ä 127).

12.1.10 Base Language Configuration

The base language is used as "template" for customer specific screen. Select the appropriate base language from the drop down list and confirm by clicking the Submit button.

12.1.11 Customer Language Configuration

Customer language = Integration of customer specific screens (modified screens based on

Tankvision pages).

• Download of one additional language pack (beside the pre installed one(s)).

• Type in the location or use the Browse button.

• Download to Tankvision by clicking on Download button.

• The additional language is shown in the meta data header.

• Can be selected as default language ("Default Language", → ä 121) or as based language

("Base Language Configuration", → ä 127).

Endress+Hauser 127

The "System" menu Tankvision

12.2

Network Setting

All Tankvision units are connected to each other using Ethernet and exchange data over

TCP/IP. Tankvision provides a web-based user interface, which allows the user to use the

Tankvision functionality by any standard web browser.

12.2.1 Tankvision Network Configuration

Each Tankvision unit has three LAN ports as shown in the figure below.

1

E

L-

L+

RESET

Fuse

2 A T

RESET

3

2

3

The picture refers to NXA820. NXA821 and NXA822 have the same LAN ports.

1 System LAN port

Sync-Link LAN port

Service LAN port

2

Ethernet-Ports_NXA820

Port

System LAN port

Sync-Link LAN port

(in preparation)

Service LAN Port

Description

Connects the Tankvision unit to the network.

The IP address of the System LAN port can be defined in Primary IP Address (→ ä 129)

in preparation

Connects the Tankvision unit to a local computer only for local commissioning and service operations. The IP address of the Service LAN Port is 192.168.1.1

128 Endress+Hauser

Tankvision The "System" menu

12.2.2 Configure the Network

The Tankvision system allows the user to configure or to modify the network settings of the

Tankvision unit.

First time configuration of a Tankvision unit

When configuring a Tankvision unit for the first time, proceed as follows:

1.

2.

3.

4.

Connect a laptop to the Service LAN port. Make sure that the laptop is configured to get a dynamic IP address from a DHCP server.

Open the internet browser and enter the following URL: http://192.168.1.1

Login to Tankvision (User ID = Super; Password = Super)

Navigate to System → Global Settings → Network Settings (see below)

5.

6.

Set the correct IP address and further network settings.

Disconnect the laptop and connect the Tankvision unit to the network via the System

LAN port.

7.

Continue to configure the Tankvision unit.

To configure the network settings

1.

Endress+Hauser

NXA82x_Network-Settings

Field

NXA82x Unit Tag

Name

Primary IP Address

Domain

Subnet Mask

Destination Network

(not mandatory)

HART Port

DNS List

(not mandatory)

Gateway

Description

Enter the tag name for the Tankvision unit. This field indicates the TCP/IP host name for the Tankvision unit. This name will be displayed in the left menu as the Tankvision unit identifier.

The tag name is alphanumeric and can contain the special characters '-' and '_' (hyphen and underscore).

Enter the IP address for the Tankvision unit. The primary IP address is used by the

Tankvision unit to participate in system functionality. The data type for this field is IP address.

Enter the domain address. The domain is the network identification of a server.

The data type for this field is alphanumeric and can contain the characters '-", '_' and '.'

(hyphen, underscore and dot).

Enter the appropriate Subnet Mask. The subnet Mask is used by TCP/IP services and applications to determine whether a given IP address on an inter-network is a local network address or a remote network address. The data type for this field is IP address.

Used to add manual entries into the network routing table.

For details contact the Endress+Hauser service.

Change the remote configuration network communication port.

Enter the IP address for the DNS list. This is a list of IP addresses of DNS servers. A DNS server is used to resolve host names into IP addresses on a TCP/IP network. If you don"t have access to a DNS server, enter 1.1.1.1. The data type for this field is IP address.

Enter the IP address of the Gateway. The gateway forwards IP addresses to other TCP/IP networks. For details contact the Endress+Hauser service.

129

The "System" menu Tankvision

2.

3.

Enter the appropriate information in the relevant fields.

Click the Submit button to proceed. The system displays a confirmation box as follows:

4.

5.

Click the OK button to proceed, or click the Cancel button to exit.

After saving the settings, the Tankvision unit restarts automatically (wait approx.

3 min).

If you don’t know the correct IP address, please contact your local network administrator. If you want to use an isolated LAN network, use the IP address

192.168.2.xxx and set the subnet mask to 255.255.255.0

130 Endress+Hauser

Tankvision The "System" menu

Network Node Detection

The Network Node Detection helps to detect and connect to all devices in the same network.

This is a precondition for a global/local scenario (e.g.to use a Data Concentrator NXA821 as a Global Store or for the usage of Subscription Stores).

To do so, proceed as follows:

1.

Login to the Tankvision unit as "Supervisor" and navigate to the Global Settings screen

as described in "Network settings", → ä 16.

2.

Endress+Hauser

NXA82x_Network-Settings_Network-Node-Detection

Field

Scan Method

Description

Select the appropriate Scan Method from this field. Choose between scanning for a single

IP address (Scan Address) and scanning a range of IP addresses (Scan Address Range).

Enter the appropriate scan timeout (in milliseconds) in the text box.

Timeout in

Milliseconds

Enter Address Enter the known IP address of a device in the network into the text boxes.

This filed is only available when Scan Address was selected for Scan Method.

Enter Address Range Enter a range of IP addresses, that are in the same network as the current device, into the text boxes.

This filed is only available when Scan Address Range was selected for Scan Method.

Message

Detected Units

Connected Units

Distrubute

Connected Units

Displays a message after the scan, e.g. how many devices were detected.

Lists all the devices that were detected during a scann.

Lists all devices that are already connected to the current device.

Select the check box to distribute the selected Detected Units to all connected units when clicking Save Connected Units.

Clear the check box to save the selected Detected Units only to the current device when clicking Save Connected Units.

3.

Enter the appropriate information in the relevant fields.

131

The "System" menu Tankvision

4.

5.

Click Perform Scan to start the Network Node Detection.

During the scan a progress bar is displayed. The rest of the screen is locked while the progress bar is displayed.

Click on the detected units (multiple selection by holding the Ctrl key while clicking) to select the detected units that are to be saved. Click Save Connected Units to save the selected units (and the current device).

Click Clear Detected Units to clear the Detected Units.

If a device in the network is removed or replaced, repeat the Network Node Detection to update the connected devices.

Monitoring Configuration

Configure the interval and timeout for monitoring the other devices in the network as well as the network quality.

To do so, proceed as follows:

1.

Login to the Tankvision unit as "Supervisor" and navigate to the Global Settings screen

as described in "Network settings", → ä 16. Click on Customer Settings.

2.

132

NXA82x_Network-Settings_Monitoring-Configuration

Column

Unit Type

Monitoring interval in Milliseconds

Timeout in

Milliseconds

Description

Displays the device type (Tank Scanner NXA820, Data Concentrator NXA821, Host Link

NXA822).

Enter the appropriate interval, in which the current device checks if the other devices in the network are available, in the text box.

Enter the appropriate timeout for the availability check of the other devices in the network in the text box.

Field

QNet-Timeout & -

Retry Setings

Description

Select the appropriate network quality. The names of the settings are self-explanatory.

3.

4.

Enter the appropriate information in the relevant fields.

Click the Save Monitoring Configuration button.

Time Server Settings

The availability of the Time Server Settings depends on the Configuration Store Type

selected in "Define Configuration Store Details" (→ ä 21).

Synchronize the time of the device with a time server in the network.

To do so, proceed as follows:

Endress+Hauser

Tankvision The "System" menu

1.

Login to the Tankvision unit as "Supervisor" and navigate to the Global Settings screen

as described in "Network settings", → ä 16. Click on Customer Settings.

2.

NXA82x_Network-Settings_Time-Server-Settings

Field

Synchronize time against time server

Server IP-Address

Description

Select the check box to synchronize the system time of the current device with a time server in the network.

Clear the check box to use the system time of the current device.

Only available if Subscription Store is selected as the Configuration Store Type in

Define Configuration Store Details (→ ä 21).

Not available if Use Local Configuration Store is selected as the Configuration Store

Type, because this setting always uses the system time of the current device.

If Use Global Configuration Store is selected as the Configuration Store Type, the IP address of the configured Subscription Store is automatically used as time server.

Enter the appropriate IP address of a time server. The IP address has to be available in the network of the current device.

Entering the IP address "127.127.1.0" (default) synchronizes with the system time of the current device.

If an invalid IP address is entered and Submit button is clicked, the field returns to the last valid IP address.

This field is only available if the Synchronize time against time server check box is available and selected.

NOTE! Do not use other Tankvision devices as time servers.

3.

4.

Enter the appropriate information in the relevant fields.

Click the Submit button.

The time of synchronization depends, amongst other things, on the network quality.

Endress+Hauser 133

The "System" menu Tankvision

12.3

Environment Settings

Environment Settings allows you to store and view information about the surrounding environment of the place where the Tankvision system is installed. This information comprises local gravity, atmospheric pressure and density of air and water.

To configure the environment settings

1.

NXA82x_Environment-Settings

Field

Local Gravity

Air Density

Atmospheric

Pressure

Water Density

Current Ambient

Temperature

NXA820 Ambient

Temperature source

Description

Enter the appropriate value for the local gravity. This field indicates the local gravity of the region where the Tankvision system is installed. The value of the local gravity should be configured in SI units only and should be greater than zero. The default value is

+9.81 m/s

2

.

The data type for this field is numeric.

Enter the appropriate value for the air density. This field indicates the density of air in the region where the Tankvision system is installed. The value of the air density should be configured in SI units only and should be greater than zero. The default value is

+1.225 Kg/m3.

The data type for this field is numeric.

Enter the appropriate value for the atmospheric pressure. This field indicates the atmospheric pressure in the region where the Tankvision system is installed. The value of the atmospheric pressure should be configured in SI units only. The data type for this field is numeric.

Enter the appropriate value for the water density. This field indicates the density of water in the region where the Tankvision system is installed. The value of the water density should be configured in SI units only and should be greater than zero. The default value is

+999 Kg/m3.

The data type for this field is numeric.

This field displays the Current Ambient Temperature used by the system for inventory calculations. The Current Ambient Temperature is obtained from NXA820 Ambient

Temperature Source. The user can click the Refresh button to refresh the ambient temperature fetched from the specified source

Enter the host name or IP address of the NXA820 ambient temperature source. It specifies the NXA820 unit in the network from where this unit receives the ambient temperature.

2.

3.

4.

Enter the appropriate information in the relevant fields.

Click the Submit button to save the settings.

After saving the settings, Tankvision displays a confirmation message.

An event is generated after configuring the Environment Settings. The event details can be viewed in the Event or Alarm & Event overview.

134 Endress+Hauser

Tankvision The "System" menu

12.4

Trend Global Settings

The Tankvision system displays the real-time and historical trend of measured data in the form of line graphs. The Trend Global Settings screen allows the user to preset colors for the grid, plot cursor, pen and background of the trend display. It can be changed in the trend views itselfs.

To Configure Trend Global Settings

1.

Endress+Hauser

Field

Background color of

Real Time Trend

Background color of

Historical Trend

Grid Color

Plot Cursor Color

Description

Click the color palette icon to select the appropriate color from the color palette.

This field displays the background color configured for the real time trend.

Click the color palette icon to select the appropriate color from the color palette.

This field displays the background color configured for the historical trend.

Click the color palette icon to select the appropriate color from the color palette.

This field displays the color configured for the grid.

Click the color palette icon to select the appropriate color from the color palette.

This field displays the color configured for the plot cursor.

Column

Pen

Pen Style

Pen Color

Description

This column displays a list of colors that can be selected for the drawing pen on the trend’s screen.

Select the appropriate pen style from the drop down list.

This column displays the types of pen styles that can be used on the trend’s screen.

Click the color palette icon to select the appropriate pen color.

This field displays the colors configured for the drawing pen.

2.

3.

4.

Enter the appropriate information in the relevant fields.

Click the Submit button to proceed.

After saving the settings, Tankvision displays a confirmation message.

An event is generated after configuring the Trend Settings. The event details can be viewed in the Event or Alarm & Event overview.

135

The "System" menu Tankvision

12.5

Field Scan - Modbus EIA485

This section is valid for the Modbus protocol. For other field protocols refer to the following sections:

• Section 12.6: Configure Field Scan - Sakura V1 (→ ä 141)

• Section 12.7: Configure Field Scan - Whessoe WM550 (→ ä 146)

The most important function of NXA820 is acquiring measured data from gauges installed in tanks. NXA820 receives measured data by means of field scanning. The measured data comprise tank parameters such as product level, product temperature, pressure, observed density, etc.

To Configure the Field Scan Settings

1.

12.5.1 Field Protocol

In order to perform field scanning, the Field Protocol needs to be configured.

To configure the field protocol

1.

NXA82x_Global-Settings_Field-Scan

Field

Field Protocol Type

Number of Retries

Description

Displays the field protocoll.

Type in the number of retries for the system to initiate Field Scanning. This field indicates the number of retries, before a field scan failure for a gauge is determined by the system.

The data type used in this field is numeric. By default, the Tankvision system selects 3 as the Number of Retries.

2.

3.

4.

Enter the appropriate information in the relevant fields.

Click the Submit button.

After saving the settings, Tankvision displays a confirmation message.

An event is generated after configuring the field protocol. The event details can be viewed in the Event or Alarm & Event overview.

136 Endress+Hauser

Tankvision The "System" menu

12.5.2 Ambient Temperature Scan - Modbus

The ambient temperature is a special parameter. In a given installation there is typically only one source of ambient temperature. This source can be the ambient temperature fetched from a spot temperature gauge on one of the tanks or a manually entered value. In the ambient temperature scan configuration for NXA820, the user can specify whether this unit receives the ambient temperature from the connected gauge or from some other NXA820 unit.

To configure the Ambient Temperature Scan

1.

Field

Current Ambient

Temperature

Ambient

Temperature Source

Description

This field displays the Current Ambient Temperature the system uses in inventory calculations. Click the Refresh button to display the latest ambient temperature.

This field allows the user to enable the Tankvision system to retrieve the ambient

temperature from (Chap. 12.3, → ä 134)

• Another NXA820 unit or

• A connected gauge

2.

3.

4.

Enter the appropriate option in the relevant fields.

Click the Submit button.

After saving the settings, Tankvision displays a confirmation message.

An event is generated after configuring the ambient temperature source. The event details can be viewed in the Event or Alarm & Event overview.

Endress+Hauser 137

The "System" menu Tankvision

12.5.3 Add Gauge Map File - Modbus EIA485

For each Modbus device you need a special map to recognize the device in Tankvision. By default basic maps for Tank Side Monitor (TSM), Proservo NMS und Remote Terminal Unit

(RTU) are present on the Tankvision Tank Scanner unit. Ask your local Endress+Hauser service to provide the correct map file.

To add a Gauge Map File

1.

2.

3.

4.

Click the Browse button and navigate to the required gauge file. Double-click the file name to enter it into the Gauge Map File field.

Click the Download File button to download the map file to the Tankvision unit.

Click the Submit button to activate the gauge map file.

12.5.4 Manage Field Scan Configuration – Modbus EIA 485

The Manage Field Scan Configuration - Modbus EIA 485 screen displays serial configuration details and gauge configuration details.

To Manage the Field Scan Configuration using Modbus EIA485

1.

on the screen as follows:

138 Endress+Hauser

Tankvision

Endress+Hauser

The "System" menu

Field

Baud Rate

Parity

EIA485 Termination

Resistor

Tank Configuration

Tank ID

Description

Select the baud rate for Modbus communication from the drop down list. Default 9600

Select the parity of the Modbus signal from the drop-down list. Default no parity.

Enables or disables the termination resistor on the fieldbus for RS485. Only needed for long fieldbus cables to reduce signal reflections.

Tank Name

Enabled

Gauge Slave Address

(DEC)

Gauge type

Modbus Register

Map

Each tank in the Tankvision system has a unique numerical value ranging from 1 to 15.

This ID represents the network address used by NXA820 for scanning the Tank Data.

Cannot be changed.

Actual tank name, which can be modified here as well as in the tank configuration

("General Details", → ä 38).

Select the check box to enable the field scanning of the respective tank.

This field is enabled, if the Enabled check box is selected. Enter the gauge slave address, which is configured between the NXA820 system and the gauge for communication. The gauge slave address can be any number from 1 to 247.

Select the appropriate Gauge Type from the drop-down list. This field is mandatory.

Select the appropriate register map file for tank and gauge (only Registermaps

downloaded to Tankvision can be used "Add Gauge Map File - Modbus EIA485",

→ ä 138).

Ambient Temperature Configuration

Enabled Select the check box to configure the ambient temperature.

Gauge Slave Address Enter the slave address of the gauge providing the ambient temperature.

Gauge type Select the appropriate Gauge Type from the drop-down list. This field is mandatory.

V1 Map File Select the appropriate V1 Map File from the drop-down list. If the appropriate Map File is

not available it must be added by the Add Gauge Map File function (→ ä 143).

2.

3.

4.

Enter the appropriate information in the relevant fields.

Click the Submit button.

After saving the settings, Tankvision displays a confirmation message.

12.5.5 Start/Stop a Field Scan

This option allows the user to start the field scan after configuring the field scan. Similarly, the field scan can be stopped at any point of time by using this option.

To start or stop field scanning

1.

NXA82x_Global-Settings_Field-Scan_Start-Stop-Field-Scan

2.

Click the Start button to start the field scanning. The Start button is enabled, if the field scan is not started. Once the field scan is started, the Start button is disabled, and the

Stop button is enabled. To stop the field scanning, click the Stop button.

An event is generated, when the field scan is started or stopped. The event details can be viewed in the Event or Alarm & Event overview.

139

The "System" menu Tankvision

12.5.6 Service Interface

Please install the Service Interface application first. → ä 195

Open the Service Interface application after successful installation and click the Start

Stat Count button. Only then, data is displayed in the Service Interface screen.

Afterwards, the application can be closed.

A separat operating manual for the Service Interface application is available and will be installed on the PC during the application installation process.

Click the Windows Start button and navigate to the Service Interface folder, where you will find the manual.

The requests from the Tank Scanner NXA820 and the ensuing responses from the field devices are evaluated in this screen. This screen is only for service purposes.

To display the service interface

1.

NXA82x_Service-Interface

Field

Requests Sent

Description

The number of total requests sent by the Tank Scanner NXA820.

Good Response The number of requests / percentage of total requests that got a good response from the field device.

Response with Error The number of requests / percentage of total requests that got a response with error from the field device.

Comm. Timeout The number of requests / percentage of total requests that got no response from the field device.

Stat Started/

Restarted Time

Time at which the evaluation was started; i.e. the time at which the Start Stat Count or

Reset Stat Count button was pressed in the Service Interface tool.

140 Endress+Hauser

Tankvision The "System" menu

12.6

Configure Field Scan - Sakura V1

This section is valid for the Sakura V1 protocol. For other field protocols refer to the following sections:

• Section 12.5: Field Scan - Modbus EIA485 (→ ä 136)

• Section 12.7: Configure Field Scan - Whessoe WM550 (→ ä 146)

The most important function of NXA820 is acquiring measured data from gauges installed in tanks. NXA820 receives measured data by means of field scanning. The measured data comprise tank parameters such as product level, product temperature, pressure, observed density, etc.

To Configure the Field Scan Settings

1.

NXA82x_Global-Settings_Field-Scan_V1

12.6.1 Field Protocol

In order to perform field scanning, the Field Protocol needs to be configured.

To configure the field protocol

1.

NXA82x_Global-Settings_Field-Scan_Field-Protocol_V1

Field

Field Protocol Type

Number of Retries

Description

The protocol type is displayed.

Type the number of retries for the system to initiate Field Scanning. This field indicates the number of retries, before a field scan failure for a gauge is determined by the system.

The data type used in this field is numeric. Default 3 Retries.

2.

3.

4.

Enter the appropriate information in the relevant fields.

Click the Submit button.

After saving the settings, Tankvision displays a confirmation message.

An event is generated after configuring the field protocol. The event details can be viewed in the Event or Alarm & Event overview.

Endress+Hauser 141

The "System" menu Tankvision

12.6.2 Ambient Temperature Scan - V1

The ambient temperature is a special parameter. In a given installation there is typically only one source of ambient temperature. This source can be the ambient temperature fetched from a spot temperature gauge on one of the tanks or a manually entered value. In the ambient temperature scan configuration for NXA820, the user can specify whether this unit receives the ambient temperature from the connected gauge or from some other NXA820 unit.

To configure the Ambient Temperature Scan

1.

Field

Current Ambient

Temperature

Ambient Temperature

Source

Get Ambient Temperature from other NXA820 Unit

Get Ambient Temperature from connected Gauge

Description

This field displays the Current Ambient Temperature the system uses in inventory calculations. Click the Refresh button to display the latest ambient temperature.

This field allows the user to enable the Tankvision system to retrieve the ambient

temperature from (Environment Settings, → ä 134)

• Another NXA820 unit or

• A connected gauge

Select this option to enable the system to obtain the Ambient Temperature from another NXA820 Unit.

Select this option to enable the system to obtain the ambient temperature from a connected gauge.

2.

3.

4.

Enter the appropriate option in the relevant fields.

Click the Submit button.

After saving the settings, Tankvision displays a confirmation message.

An event is generated after configuring the ambient temperature source. The event details can be viewed in the Event or Alarm & Event overview.

142 Endress+Hauser

Tankvision The "System" menu

12.6.3 Add Gauge Map File - V1

For each parity V1 device you need a special map to recognize the device in Tankvision. By default basic maps for Tank Side Monitor (TSM), Proservo NMS and Remote Terminal Unit

RTU are present on the Tankvision unit. Ask your local Endress+Hauser service to provide the correct map file.

To add a Gauge Map File

1.

2.

3.

4.

Click the Browse button and navigate to the required gauge file. Double-click the file name to enter it into the Gauge Map File field.

Click the Download File button to download the map file to the Tankvision unit.

Click the Submit button to activate the gauge map file.

Endress+Hauser 143

The "System" menu Tankvision

12.6.4 Manage Field Scan Configuration - V1

In this screen it is possible to select the address and the V1 map to be used for each gauge.

Before changing the field scan configuration it is necessary to stop the field scan (→ ä 145).

To manage the field scan configuration

1.

Click follows: on

144

Field Description

Physical Interface Configuration

Pulse Period Defines the pulse period (comparable to the baud rate).

Pulse Amplitude

Tank Configuration

Tank ID

Tank Name

Enabled

Gauge Slave Address

(DEC)

Gauge type

V1 Map File

Allows to amplify the signal in case of long cables or poor signal transmission.

Each tank in the Tankvision system has a unique numerical value ranging from 1 to 15.

This ID represents the network address used by NXA820 for scanning the Tank Data.

Enter the user defined tank name into this field.

Select the check box to enable the field scanning of the respective tank.

This field is enabled, if the Enabled check box is selected.

Enter the gauge slave address, which is configured between the NXA820 system and the gauge for communication. The gauge slave address can be any number from 1 to 247.

Select the appropriate Gauge Type from the drop-down list. This field is mandatory.

Select the appropriate V1 Map File from the drop-down list. If the appropriate Map File is

not available it must be added by the "Add Gauge Map File - V1" function (→ ä 143).

Ambient Temperature Configuration

Enabled Select the check box to configure the ambient temperature.

Gauge Slave Address Enter the slave address of the gauge providing the ambient temperature.

Gauge type Select the appropriate Gauge Type from the drop-down list. This field is mandatory.

Endress+Hauser

Tankvision The "System" menu

Field

V1 Map File

Description

Select the appropriate V1 Map File from the drop-down list. If the appropriate Map File is

not available it must be added by the "Add Gauge Map File - V1" function (→ ä 143).

2.

3.

4.

Enter the appropriate option in the relevant fields.

Click the Submit button.

After saving the settings, Tankvision displays a confirmation message.

12.6.5 Start/Stop a Field Scan

This option allows the user to start the field scan after configuring the field scan. Similarly, the field scan can be stopped at any point of time by using this option.

To start or stop field scanning

1.

NXA82x_Global-Settings_Field-Scan_Start-Stop-Field-Scan

2.

Click the Start button to start the field scanning. The Start button is enabled, if the field scan is not started. Once the field scan is started, the Start button is disabled, and the

Stop button is enabled. To stop the field scanning, click the Stop button.

An event is generated, when the field scan is started or stopped. The event details can be viewed in the Event or Alarm & Event overview.

Endress+Hauser 145

The "System" menu Tankvision

12.7

Configure Field Scan - Whessoe WM550

This section is valid for the Whessoe WM550 communication protocol. For other field protocols refer to the following sections.

The most important function of NXA820 is acquiring measured data from gauges installed in tanks. NXA820 receives measured data by means of field scanning. The measured data comprise tank parameters such as product level, product temperature, pressure, oberserved density...

12.7.1 Field Protocol

In order to perform field scanning, the Field Protocol needs to be configured.

To configure the field protocol

1.

NXA82x_Global-Settings_Field-Scan_Field-Protocol_WM550

Field

Field Protocol Type

Number of Retries

Description

The protocol type is displayed.

Typ of number of retries for the system to initiate Field Scanning. This field indicates the number of retries, before a field scan failure for a gauge is determined by the system. The data typ used in this field is numeric. Default 3 retries.

2.

3.

4.

Enter the appropriate information in the relevant fields.

Click the Sumit button.

After saving the settings, Tankvision displays a confirmation message.

An event is generated after configuring the field protocol. The event details cn be viewed in the Event or Alarm & Event overview.

146 Endress+Hauser

Tankvision The "System" menu

12.7.2 Ambient Temperature Scan

The ambient temperature is a special parameter. In a given installation there is typically only one source of ambient temperature. This source can be the ambient temperature fetched from a spot temperature gauge on one of the tanks or manually entered value. In the ambient temperature scan configuration for NXA820, the user can specify whether this unit receives the ambient temperature from the connected gauge or from some other NXA820 unit.

To configure the Ambient Temperature Scan

1.

Field

Current Ambient

Temperature

Ambient Temperature

Source

Get Ambient Temperature from other NXA820 Unit

Get Ambient Temperature from connected Gauge

Description

This field displays the Current Ambient Temperature the system uses in inventory calculations. Click the Refresh button to display the latest ambient temperature.

This field allows the user to enable the Tankvision System to retrieve the ambient

temperature from (Environment Settings, → ä 134)

• Another NXA820 unit or

• A connected gauge

Select this option to enable the system to obtain the Ambient Temperature from another NXA820 unit.

Select this option to enable the system to obtain the ambient temperature from a connected gauge.

2.

3.

4.

Enter the appropriate information in the relevant fields.

Click the Sumit button.

After saving the settings, Tankvision displays a confirmation message.

An event is generated after configuring the field protocol. The event details can be viewed in the Event or Alarm & Event overview.

Endress+Hauser 147

The "System" menu Tankvision

12.7.3 Add Gauge Map File

For each parity WM550 device you need a special map to recognize the device in Tankvision.

By default basic maps for Tank Side Monitor (TSM), Proservo NMS and Remote Terminal

Unit RTU are present on the Tankvision unit. Ask your local Endress+Hauser service to provide the correct map file.

To add a Gauge Map File

1.

2.

3.

4.

Click the Browse button and navigate to the required gauge file. Double-click the file name to enter it into the Gauge Map File field.

Click the Download File button to download the map file to the Tankvision unit.

Click the Submit button to activate the gauge map file.

148 Endress+Hauser

Tankvision The "System" menu

12.7.4 Manage Field Scan Configuration

In this screen it is possible to select the address and the Whessoe WM550 map to be used for each gauge. Before changing the field scan configuration it is necessary to stop the field

scan → ä 145.

To manage the field scan configuration

1.

on as follows:

Endress+Hauser

Field Description

Physical Interface Configuration

Baud Rate

Loop Current

Defines the WM550 protocol baud rate. Possible values are 300, 600, 1200, 1800, 2400,

4800.

This field defines the current in the Whessoe WM550 loop to be set by the internal electronic. This current will be hold by the Master regardless the number of slaves that are connected. Possible values ranges between 16 mA and 30 mA.

Tank Configuration

Tank ID Each tank in the Tankvision system has a unique numerical value ranging from 1 to 15.

This ID represents the network address used by NXA820 for scanning the Tank Data.

Tank Name

Enabled

Enter the user defined tank name into this field.

Select the check box to enable the field scanning of the respective tank.

Gauge Slave Address

(DEC)

This field is enabled, if the Enabled check box is selected. Enter the gauge slave address, which is configured between the NXA820 system and the gauge for communication. The gauge slave address can be any number from 0 to 63 for the Whessoe WM550.

Gauge Type

WM550 Map File

Select the appropriate Gauge Type from the drop-down list. This field is mandatory.

Select the appropriate WM550 Map File from the drop-down list. If the appropriate map

File is not available it must be added by the Add Gauge Map File function.

2.

3.

Enter the appropriate information in the relevant fields.

Click the Submit button.

149

The "System" menu Tankvision

4.

After saving the settings, Tankvision displays a confirmation message.

12.7.5 Start/Stop Field Scan

This option allows the user to start the field scan after configuring the field scan. Similarly, the field scan can be stopped at any point of time by using this option.

To start or stop field scanning

1.

NXA82x_Global-Settings_Field-Scan_Start-Stop-Field-Scan

2.

Click the Start button to start the field scanning. The Start button is enabled, if the field scan is not started. Once the field scan is started, the Start button is disabled, and the

Stop button is enabled. To stop the field scanning, click the Stop button.

An event is generated, when the field scan is started or stopped. The event details can be viewed in the Event or Alarm & Event overview.

150 Endress+Hauser

Tankvision The "System" menu

12.8

W&M Seal

The W&M seal allows you to view the W&M sealing status and to perform the access configuration for W&M secured systems.

To Change the W&M Approved Status

Field

W&M Information

Description

Shows detailed information of sealing status for a device:

• W&M Switch status

• W&M CRC at sealing time

• Time of sealing

• Last calculated W&M CRC

• Last calculated CRC’s time stamp

Access Configuration Registration page to configure access rights for a PC that can access the device after sealing.

12.8.1 W&M Information

Field

This page is static and is loaded at:

Description

Displays the date and time when the screen was locked. This is a static page meaning no auto update is running.

W&M switch status Displays the current W&M switch status.

The status can be sealed (closed W&M switch) or unsealed (open W&M switch).

CRC at sealing time A checksum is calculated with closing the W&M switch. This checksum is displayed in this field.

Time of sealing

Last calc. W&M CRC time step

Displays the date and time the sealing took place.

Last Calc. W&M CRC Displays the latest calc. W&M checksum. The checksum is recalculated on a regular basis.

In case of an mismatch of the recalculated checksum with the initial checksum, the system was manipulated.

Displays date and time of the last calculated W&M checksum.

Endress+Hauser 151

The "System" menu Tankvision

12.8.2 Access Configuration

In sealed systems only registered Users/PC’s are allowed to have access to the system functionality. The access configuration provides the possibility to ensure the access. The access configuration is based on MAC Address.

Field

Registered Systems

Current MAC

Address

Description

Displays the MAC Address of the currently registered PC.

• Registered:

Registers the PC which is connected to the system (current workstation). The PC’s must be in the same Network as Tankvision (no router/gateway in between).

Registration must be performed from every PC which should have access to the system individually.

• Unregistered:

To unregister PC(s) mark them in the list on the left hand side (select several by pressing "Ctrl" and marking them) and click unregister. The unregistered PC’s will not have access to the system after sealing.

Displays the current MAC Address of the workstation.

This section is sealed for editing after switching the W&M switch to close.

152 Endress+Hauser

Tankvision

12.9

Data Archival

12.9.1 Configure Data Archival

Enable Disable Tanks/Tank Group

The "System" menu

Endress+Hauser

Field

Available Tanks

Selected Tanks

Description

This list displays the tanks that are available for grouping.

This list displays the tanks that are grouped to the tank group.

Click this button to transfer the selected tank(s) from the Available Tanks list to the

Selected Tanks list. (Several tanks can be selected by holding the Ctrl button with clicking on the tanks)

Click this button to transfer all tanks from the Available Tanks list to the Selected

Tanks list.

Click this button to de-select the tank(s) from the Selected Tanks list to the Available

Tanks list. (Several tanks can be selected by holding the Ctrl button with clicking on the tanks).

Click this button to de-select all tanks from the Selected Tanks list to the Available

Tanks list.

153

The "System" menu

Configure Parameters and Interval

Configure Tank Parameters

Tankvision

NXA82x_Data-Archival_Configure-Tank-Parameters

Select Tanks and Parameters:

• Select tank / all tanks and the tank parameter → Click Add or Remove to add or delete the relevant parameter from working.

• List of tanks and selected parameters for the tank.

Configure Tank Group Parameters

154

NXA82x_Data-Archival_Configure-Tank-Group-Parameters

Select Tank Groups and Parameters:

• Select tank group/ all tank groups and the tank parameters → Click Add or Remove to add or delete the relevant parameter from working.

• List of tank groups and selected parameters for the tank.

Endress+Hauser

Tankvision

Configure Archive Interval

The "System" menu

Selecting the archival interval daily or greater. The archival time is selectable.

• Min archival interval: 1 min

• Max archival interval: 1 week (7 days)

• Default: 5 min

Start / Stop Archival

NXA82x_Data-Archival_Start-Stop-Archival

• Start Archiving → no changes in settings

• Stop Archiving → changes in settings are possible

Endress+Hauser 155

The "System" menu

12.9.2 Export Archived Data

Configure Export Data

Tankvision

156

Field

Select for Export

Export All

Selected Data for

Export (manual scheduled)

Select Type of File to export

Description

Data selection of exported data:

• Tank

• Tankgroups

Select this option to export complete set of stored data. User can define if source shall be deleted after successful export.

Export configuration page. The user can select / configure a manual export (one time event) or a sheduled export.

Define the format of exported data: CSV / SQL

Stop Scheduled Export

Endress+Hauser

Tankvision

12.9.3 View Archived Data

The "System" menu

Field Description

View Historical Trend User operational page to define value(s) of tank(s) which shall be displayed in a graph.

Trend Configuration Pen configuration page for the historical graph.

View Historical Trend

Select Tank or Tank Groups and Intervall which should be displayed and continue by clicking

Configure Pens. Tankvision displays the screen as follows:

Endress+Hauser

Click on View Historical Trend. Tankvision displays the Historical Trend as follows:

157

The "System" menu Tankvision

158

NXA82x_Historical-Trend_View

Refer to the "View Real Time Trend" section (→ ä 73) for the description of the above screen.

Endress+Hauser

Tankvision

Trend Configuration

Configuration of the Trend screen.

The "System" menu

Endress+Hauser

Column

Pen

Pen Style

Pen Color

Description

This column displays a list of colors that can be selected for the drawing pen on the trend’s screen.

Select the appropriate pen style from the drop down list. This column displays the types of pen styles that can be used on the trend’s screen.

Click the color palette icon to select the appropriate pen color.

This field displays the colors configured for the drawing pen.

159

The "System" menu Tankvision

12.10 Tank Scanner Unit and Tank Assignment

Up to 15 Tank Scanners with their tanks can be assigned to the Data Concentrator. All tanks can then directly be accessed via the Data Concentrator. Tank Groups can be formed containing tanks connected to different Tank Scanners.

To assign a Tank Scanner NXA820 to the Data Concentrator NXA821

1.

on as follows:

Field

Available Units

Selected Units

Description

This list displays the <tank name(s)> that are available for grouping.

This list displays the <tank name(s)> that are grouped to the tank group.

Click this button to transfer the selected Tank Scanner(s) from the Available Tanks list to the Selected Tanks list.

Click this button to transfer all Tank Scanners from the Available Tanks list to the

Selected Tanks list.

Click this button to de-select the Tank Scanner(s) from the Selected Tanks list to the

Available Tanks list.

Click this button to de-select all Tank Scannerrs from the Selected Tanks list to the

Available Tanks list.

2.

3.

Move all Tank Scanner units that are to be assigned to the Data Concentrator into the

Selected Units Field.

Click the Submit button to add assign the Tank Scanners to the Data Concentrator.

When the Tank Scanners NXA820 have been assigned to the Data Concentrator

NXA821, all the connected Tanks can be operated via the NXA821 as well as via the respective NXA820.

160 Endress+Hauser

Tankvision The "System" menu

12.11 Host Link

The Host Link NXA822 provides an interface for a host system to access inventory data from a Tank Scanner NXA820. To configure the Host Link settings, proceed as follows:

12.11.1 Host Link Configuration

1.

2.

3.

Select MODBUS TCP or MODBUS Serial from the Host Link Protocol drop-down list.

By default, the system displays MODBUS Serial.

Click the Submit button to save the host link protocol type. After saving the settings,

Tankvision displays a confirmation message.

Observe the following information!

• An event is generated after setting the host link type. The event details can be viewed in the Event or Alarm & Event overview.

• The system displays MODBUS Serial Configuration or MODBUS TCP Configuration, respectively, on the following sub-header.

Endress+Hauser 161

The "System" menu Tankvision

12.11.2 Import Modbus Coil Map For Alarm Status

The MODBUS Input Status (1X) is used to provide an Active or In-active alarm status. The

MODBUS Coil Status (0X) is used for acknowledging the alarm and to provide the "Alarm

Acknowledgement" status.

The MODBUS coil map can be configured as an XML file. The XML file contains the configuration for mapping alarms and acknowledgement statuses for the associated Tank.

NXA822 helps the user to import the XML file containing the coil map for alarm status and acknowledgement status.

Sample XML for "MODBUS coil map for alarm status"

162

NXA82x_Sample-XML_MODBUS-coil-map-for-alarm-status

Endress+Hauser

Tankvision The "System" menu

To import an XML file containing a MODBUS coil map for alarm status information

1.

2.

Click Import MODBUS Coil Map For Alarm Status. Tankvision displays the screen as follows:

Field

Select XML file for

MODBUS coil map for

Alarm Status

Description

Click the Import button to import the XML file containing the coil map.

3.

Click the Import button to import the file. Tankvision displays the screen as follows:

4.

5.

6.

Click the Browse button to import the file. Tankvision displays the screen for selecting the XML file from the appropriate location.

Enter the location from where you want to upload the file or click the Browse button and select the XML from the appropriate file location.

Click the Send button to proceed. The system displays the XML file next to the Select

XML file for MODBUS register map for Gauge Commands field as follows:

Endress+Hauser

7.

Click the Submit button. After successfully downloading the coil map configuration

XML file, Tankvision displays a confirmation message.

163

The "System" menu Tankvision

164

Column

Tank Id

Description

This column displays the identity of tanks corresponding to the NXA820 IP Address.

NXA820 IP Address This column displays the unit tag name of NXA820.

Number of Alarms This column displays the number of alarms configured for each tank unit.

Observe the following information!

• The updated list of alarms configured for each associated tank to NXA822 is displayed on the Import MODBUS Coil Map for Alarm Status screen.

• An event is generated after downloading the coil map configuration XML file. The event details can be viewed in the Event or Alarm & Event overview.

12.11.3 Import Modbus Register Configuration for Gauge Commands

MODBUS register for gauge commands is used to send gauge commands for a tank and to display the status of the currently active gauge command.

The MODBUS register for gauge commands can be configured in an XML file.

NXA822 helps the user to import the XML file containing the gauge command configuration.

Sample XML for "Register Configuration for Gauge Commands"

NXA82x_Sample-XML_Register-Configuration-for-Gauge-Commands

Endress+Hauser

Tankvision The "System" menu

To import an XML file containing a MODBUS register configuration for gauge command

1.

2.

Click Import MODBUS Register Configuration for Gauge Commands. Tankvision displays the screen as follows:

Field

Select XML file for

MODBUS register map for Gauge

Commands

Description

Click the Import button to import the XML file containing the gauge command configuration.

3.

Click the Import button to import the file. Tankvision displays the screen as follows:

4.

5.

6.

Click the Browse button to import the file. Tankvision displays the screen for selecting the XML file from the appropriate location.

Enter the location from where you want to upload the file or click the Browse button and select the XML from the appropriate file location.

Click the Send button to proceed. The system displays the XML file against the Select

XML file for MODBUS register map for Gauge Commands screen as follows:

Endress+Hauser

7.

Click the Submit button. After successfully downloading the gauge command map configuration XML file, tankvision displays a confirmation message.

165

The "System" menu Tankvision

Column

Tank Id

Description

This column displays the identity of tanks corresponding to the NXA820 IP

Address.

NXA820 IP Address This column displays the unit tag name of NXA820.

Gauge Command Register The register allows to send a command to the Gauge.

Gauge Command Status

Register

This register provides the status of the command send to the Gauge.

Observe the following information!

• The updated list of gauge command register and gauge command status register for each associated tank is displayed on the Import MODBUS Register Configuration for Gauge

Commands screen.

• An event is generated after downloading the gauge command map configuration XML file.

The event details can be viewed in the Event or Alarm & Event overview.

166 Endress+Hauser

Tankvision The "System" menu

12.11.4 Import Modbus Register Map for Parameters

The Modbus register map provides information about the mapping of MODBUS registers to the appropriate tank parameters.

The Modbus register map for tank parameters can be configured in an XML file.

The XML file can be developed in two different structures, viz, "simple approach" and "XML with orientation". In the simple approach the register addresses for all the parameters are explicitly provided by the user in XML.

In the XML with data orientation approach the register addresses are generated implicitly based on the orientation type and the block addresses provided by the user.

The orientation can be data or elements. If the orientation type is elements, then all tanks of one parameter are grouped in consecutive registers.

If the orientation type is data, then all the parameters of a tank are grouped. When the orientation parameters are grouped according to the orientation specified, the groups formed by the orientation are called blocks, and the address of the first register of the block is the block address.

NXA822 helps the user to import the XML file containing the tank parameters configuration from an appropriate network location.

Sample XML for "Register Map for Parameters having simple approach"

Endress+Hauser

NXA82x_Sample-XML_Register-Map-Parameters-simple-approach

167

The "System" menu Tankvision

Sample XML for "Register Map for Parameters having orientation type as elements"

168

NXA82x_Sample-XML_Register-Map-Parameters-orientation-type-elements

Endress+Hauser

Tankvision The "System" menu

Sample Register Map for Parameters file having orientation type as data

NXA82x_Sample-XML_Register-Map-Parameters-file-orientation-type-data

To import an XML file containing the MODBUS register map for parameters

1.

Endress+Hauser

2.

Click Import Modbus Register Map for Parameters. Tankvision displays the screen as follows:

169

The "System" menu Tankvision

Field

Select XML file for

MODBUS register map for

Gauge Commands

Description

Click the Import button to import the XML file containing the gauge command configuration.

3.

Click the Import button to import the file. Tankvision displays the screen as follows:

4.

5.

6.

Click the Browse button to import the file. Tankvision displays the screen for selecting the XML file from the appropriate location.

Enter the location from where you want to upload the file, or click the Browse button and select the XML file from the appropriate location.

Click the Send button to proceed. The system displays the XML file next to the Select

XML file for MODBUS register map for parameters screen as follows:

7.

Click the Submit button. After successfully downloading the parameter map configuration XML file, Tankvision displays a confirmation message.

170

Column

Tank Id

Description

This column displays the identity of the tanks corresponding to the NXA820 IP Address.

NXA820 IP Address This column displays the unit tag name of the NXA820.

Number of

Parameters

This column displays the number of parameters configured for each tank unit.

Observe the following information!

Endress+Hauser

Tankvision The "System" menu

• The updated list of gauge command registers and gauge command status registers for each associated tank to NXA822 is displayed on the Import MODBUS Register

Configuration for Gauge Commands screen.

• An event is generated after downloading the gauge command map configuration XML file.

The event details can be viewed in the Event or Alarm & Event overview.

Endress+Hauser 171

The "System" menu Tankvision

12.11.5 MODBUS Serial

If MODBUS Serial is selected in the Host Link configuration section, then the system will allow to configure parameters related to MODBUS Serial.

To configure Modbus Serial

1.

NXA822_Host-Link_MODBUS-Serial

Field

Slave ID

Baud Rate

Parity

Serial Link

EIA485 Termination

Resistor

Description

Assign a unique and valid slave ID to your NXA822 unit.

The data type for this field is positive integer in the range of 1 to 247.

Select the appropriate baud rate from the drop-down list.

The default baud rate is 1200 bits per second.

Select the appropriate parity for serial communication from the drop-down list.

Select the appropriate physical layer. This field allows you to select either RS232 or

EIA485.

Select the check box to enable the EIA485 Termination Resistor. Clear the check box to disable the EIA485 Termination Resistor.

2.

3.

Enter the appropriate options in the relevant fields.

Click the Submit button. After saving the settings, Tankvision displays a confirmation message.

Observe the following information!

• NXA822 initializes the serial link using the Baud Rate and Parity settings.

• An event is generated after configuring the MODBUS Serial settings. The event details can be viewed in the Event or Alarm & Event overview.

172 Endress+Hauser

Tankvision The "System" menu

12.11.6 Modbus TCP Configuration

If MODBUS TCP is selected in the Host Link Protocol section, then the system will allow to configure parameters related to MODBUS TCP.

To configure Modbus TCP

1.

on as follows:

Field

IP Address

Slave ID

Port

Description

The system displays the IP address which is configured in the network settings.

Assign a unique and valid slave ID to your NXA822 unit.

The data type for this field is positive integer in the range of 1 to 247.

Enter a unique port number on which you want to configure the NXA822 MODBUS slave.

The data type for this field is positive integer in the range of 1 to 32767.

2.

3.

Enter the appropriate options in the relevant fields.

Click the Submit button. After saving the settings, Tankvision displays a confirmation message.

An event is generated after configuring the MODBUS TCP settings. The event details can be viewed in the Event or Alarm & Event overview.

Endress+Hauser 173

The "System" menu Tankvision

12.11.7 Entis Host Protocol

Introduction

Introduction Entis+ host protocol

Enraf provides for their tank systems Entis+ the Entis Host protocol to connect to host system. The physical layer is normally the RS232 interface, but in our case also RS484 is possible.

Protocol structure

The protocol is designed as ASCII-Protocol. The transmission flow is quite simple:

The Host sends a request and the "Entis system" must answer. There is no special handshake between both. The telegram is starting with STX (Hex02) followed by data. The data and additional information are separated by a separator sign. The telegram is ending with an

ETX (Hex03). A Block control character is added, either before or after the ETX. The structure is as following for the Host request:

[STX]<request code no.><name><command, request><data><[ETX][LRC], e.g for an Entity request code 1. [STX]1TNK-01[ETX][LRC]

The answer telegram is depending on the packet type requested:

[STX]<execution code>/<name>/<data>/[ETX][LRC], e.g. for an Entity request code 1.

[STXJ0/TNK-01/07-28-92/11:58:24/_269/-1-/+/_21.0/-/NORMAL/B/_727.40/

_32.65/_27.62/_20.09[ETX][LRC].

The execution code indicates the status of the reply package:

• "0" request executed successfully

• "1" request NOT executed successfully

• "2" the last entity in a successfull group request

Supported codes by the NXA822 are:

1. The entity request, code 1, which is used to get the data of one tank.

2. The group request, code 2, to get the data of all tanks a defined group.

3. The download command, code 3, to write a density value to a tank on the NXA820.

174 Endress+Hauser

Tankvision The "System" menu

Configuration

The configuration of the Entis host protocol consists of two different parts:

One is the Web-based configuration of the protocol properties, the other part is the XMLbased settings of the tank names and groups.

Selection Entis Host

To use the Entis host protocol select in system in the Host link menu the submenu Hostlink

Configuration. In Hostlink protocol select Entis+ and submit.

NXA822_Host-Link_Host-Link-Configuration_Entis_Drop-Down

The following screen will be displayed:

NXA822_Host-Link_Host-Link-Configuration_Entis

The file has to be downloaded like the Hostlink configuration XML-file:

In the Hostlink configuration menu select Import Tank Map XML For Entis. Then you can download and submit the tank map for the Hostlink.

Endress+Hauser

NXA822_Host-Link_Host-Link-Configuration_Entis_Success

If the syntax of the XML file is correct the date will be accepted.

A XML file has to be created defining group names and tank names to specify what can be polled by the Host.

The important tags are:

1. Group tag: <GROUP_ENTRY NAME="Group name">

2. Tag to specify the NXA820 source: <HOST NAME="QNX224">

3. Tank name tag: <TANKNAME>Tank name</TANKNAME>

The group name and tank name must match the specified name length in the protocol (6 or

8 characters maximum length). The names are either included in the start tag (group,

NXA820 name) or between start and end tag (tank name).

Entis host refers to a tank with tank name and therefore it is important that tank names are unique across NXA820 units.

See below a sample XML for import file:

175

The "System" menu Tankvision

176

NXA822_Sample-XML_Entis-map

Common protocol configuration

The configuration of the Entis+ protocol consists of four submenus to configure:

1. Communication protocol settings

2. Entis+ Envelope settings

3. Numeric settings

4. Reply package settings

Entis+ standard host communication protocol settings

The protocol settings define the usual settings for a serial ports like baud rate, parity stop bits a.s.o.

NXA822_Host-Link_Host-Link-Configuration_Entis-Communication

The duplex setting is only interesting for the RS485 interface and depends on the wiring, two or four wires. RS232 is by default full duplex.

Endress+Hauser

Tankvision The "System" menu

Entis+ standard host protocol envelope settings

In this chapter you can configure the frame settings of the Entis+ host protocol.

Endress+Hauser

NXA822_Host-Link_Host-Link-Configuration_Entis-Envelope

Field

Field Separator character

Decimal separator character

Host requests as events

Description

The field separator character divides the individual fields in a reply packet, to make it more readable. You can choose any available character as the field separator.

You can choose to separate the integer and fractional part of values in a packet with either a comma (",") or a point (".").

You can choose to record every request the HOST makes in the list of events. If the HOST is making frequent requests it is better to disable this option otherwise the <F9> event screen will be swamped when you run the Master Program. But if only occasional request are made, enabling Ws option provides a good means of monitoring Host communications.

Selection of the telegram end character. The default is STX but any unused ASCII character is available.

Selection of the telegram end character. The default ist ETX.

Packet [START] character

Packet [END] character

Type of [LRC] calculation

Position of the [LRC] byte

In Host communications longitudinal redundancy checking helps detect corrupted packets. You can choose from the following checks:

• No Check:

If the protocols used by the HOST do not have LRC checking, the LRC facility may be disabled. In this case, the only checking will be parity checking (see communication protocol above).

• Odd Parity

This is defined by ANSI X 3.28 as follows: The BCC is generated by taking a binary sum independently (without carry) on each of the seven individual levels of the transmitted code. At each level, the number of one bits (including any in the BCC) is odd. In the summation, the STX is excluded when it is selected and the ETX is included.

• Even Parity

The same as above except that the number of one bits is even.

You can choose to have the LRC byte before the end character or after it. If you select the

LRC byte to appear before the end character, it will be inverted when it happens to be the same as the end character. So, if your end character is [ETX], ordinal 3, and in one instance the LRC also happens to be [ETX], then the LRC is inverted to 127-3, the ordinal

24. (For 8 bit words this is 255-3, the ordinal 252). For example, with the LRC after the

End character:

Request record for TANK-1: [STX]1TANK-1[ETX][LRC]

And with the LRC before the End character:

Request record for TANK-1: [STX]1TANK-1[LRC][ETX]

Start character in

[LRC] calculation

You can select whether the start character should be included or excluded in the LRC calculation. Normally it is excluded.

Filler for invalid data A field which is undefined or invalid due to a fail condition will have all the character positions filled with this character. You can select any available character, the default is

"*".

177

The "System" menu Tankvision

Field Description

Filler for blank data Leading blank position in the <name> field are always filled in with ASCII spaces but those preceding numeric fields can be selected. The default setting is the underscore, "_".

The numerical values are right-justified and the remaining spaces are filled with the filler for blank data character.

Entis+ standard host protocol numeric settings

Here you define the format and the dimensions of the transfered values.

178

NXA822_Host-Link_Host-Link-Configuration_Entis-Parameters

Field

Units

Field width

Decimals

Description

The drop down menu shows the available units for this specific value type you can select.

You can enter a width from 4 to 15 characters in one field. This data were right-justified

(the last figure always occupies the last possible field space). If the number is too large for the field width that you have configured, then the field is filled with the invalid data character.

Observe the following information!

1. Decimal points or commas are also a character.

2. If the data length is to large, the field is filled with the "invalid" character.

You can enter a number from 0 to 8 to set the number of numerals after the decimal point or comma.

Special parameters:

Field

PC length

Name length

Date format

Description

The Product Code (PC) for chemical products contains a numbered code (between 00 and

99). If the system uses chemical products, select 2, else select 1. The filler for blank data is used to fill a two character field with a single character code.

Selection of the width for whether the product/group name will consists of 6 or 8 characters. The names in the name field are left-justified.

This parameter gives you the possibility to select the format the date displayed. You can either have the European DD-MM-YY format or the U.S standard MM-DD-YY format.

Endress+Hauser

Tankvision The "System" menu

Entis+ reply package

In the reply package you define the values to be transmitted for a single entity or a group line. This reply package format is according to the version 5.23x of the Entis+ protocol with the important difference that you can’t select some additional information of the original specification!

Not available is SW (software alarm), HW (hardware alarm) and EX (external alarm)!

In the telegram all of these information of a parameter is separated by the field separator.

NXA822_Host-Link_Host-Link-Configuration_Entis-Reply-Packet

As in all pages a selection or changes has to be submitted with the Submit button.

Start / stop Hostlink

Starting the Hostlink communication will block all settings for changes of the parameter.

Endress+Hauser 179

The "System" menu

12.11.8 Start/Stop Host Link

When it has been configured, the Host Link can be started.

To start the host link

1.

Tankvision

2.

Click the Start button to activate the host link, or click the Stop button to deactivate the host link. If the Host Link is not activated, then the Start button will be enabled and the

Stop button will be disabled. Likewise, if the Host Link is activated, then the Stop button will be enabled and the Start button will be disabled.

180 Endress+Hauser

Tankvision The "System" menu

12.12 Downloads

12.12.1 Download Report Templates

Tankvision generates various tank inventory reports. Reports are generated using report templates. The parser in the system parses the report templates, and generates the final report based on the inventory data. Tankvision provides default or standard templates for tank inventory reports. Tankvision also allows the user to add new report templates.

If you need help to create a new report template, contact your Endress+Hauser service representative.

To download a New Report Template

1.

NXA82x_Global-Settings_Downloads

2.

NXA82x_Global-Settings_Downloads_Download-Report-Templates

Field

Report Type

Language

Template Name

File

Description

Select the appropriate report type from the drop-down list. There are the following report types:

• Product Transfer Report

• Tank Delta Report (only available if "stand alone" has been selected in the network) settings)

• Tank Details Report (only available if "stand alone" has been selected in the network)

• Tank Group Details Report (only available if "stand alone" has been selected in the network)

• Inventory Report

Select the appropriate language name from the drop-down list.

Enter the name of the template in this field. The data type is alphanumeric. The system does not accept special characters and spaces in the template name.

Enter the location from where you want to download the file. You can also click the

Download button to select the location.

3.

Click the Download button. Tankvision displays the screen as follows:

Endress+Hauser

4.

5.

Click the Browse button, select the file name, and click the Open button.

The file name is displayed in the Upload File text box.

181

The "System" menu

6.

Click the Send button. Tankvision displays the screen as follows:

Tankvision

NXA82x_Global-Settings_Downloads_Download-Report-Templates_after-browsing

7.

8.

Click the Submit button.

After saving the settings, Tankvision displays a confirmation message.

Observe the following information!

• The system generates an event when a new report template is downloaded. This information can be viewed in the Event or Alarm & Event tab.

• It is impossible to repeat or reuse old template names.

12.12.2 Download Logo Image For Printer Agent

To Download the Logo Image For Printer Agent

1.

NXA82x_Global-Settings_Downloads

2.

on

Tankvision displays the screen as follows:

3.

4.

5.

6.

Click the Browse button, select the file name, and click the Open button.

The file name is displayed in the Upload File text box.

Click the Submit button.

After saving the settings, Tankvision displays a confirmation message.

182 Endress+Hauser

Tankvision The "System" menu

12.12.3 Download Report Templates For Printer Agent

Tankvision generates various tank inventory reports. Reports are generated using report templates. The parser in the system parses the report templates, and generates the final report based on the inventory data. Tankvision provides default or standard templates for tank inventory reports. Tankvision also allows the user to add new report templates. If you need help to create a new report template, contact your Endress+Hauser service representative.

To download Report Template for Printer Agent

1.

NXA82x_Global-Settings_Downloads

2.

on screen as follows:

Endress+Hauser

Field

Report Type

Template Name

File

Description

Select the appropriate report type from the drop-down list. There are the following report types:

• Tank Delta Report (only available if "stand alone" has been selected in the network) settings)

• Tank Details Report (only available if "stand alone" has been selected in the network)

• Tank Group Details Report (only available if "stand alone" has been selected in the network)

Enter the name of the template in this field. The data type is alphanumeric.

The system does not accept special characters and spaces in the template name.

Enter the location from where you want to download the file. You can also click the

Download button to select the location.

3.

Click the Download button. Tankvision displays the screen as follows:

4.

5.

6.

Click the Browse button, select the file name, and click the Open button.

The file name is displayed in the Upload File text box.

Click the Send button. Tankvision displays the screen as follows:

183

The "System" menu Tankvision

NXA82x_Global-Settings_Downloads_Download-Report-Templates_after-browsing

7.

8.

Click the Submit button.

After saving the settings, Tankvision displays a confirmation message.

The system generates an event when a new report template is downloaded. This information can be viewed in the Event or Alarm & Event tab. It is impossible to repeat or reuse old template names.

184 Endress+Hauser

Tankvision The "System" menu

12.13 Operator Workstation Settings

Like any other web based system where users access the system via a web browser,

Tankvision uses the concept of user sessions to maintain user specific data for a session of user interactions with the system. A new session is created whenever an user accesses the system via a web browser. The user session is automatically removed after a session timeout, which occurs after a certain interval of user inactivity.

The Tankvision system uses user sessions to hold user settings and user data changed by the user. The session is also used to validate user credentials. User credentials are used to verify the user’s access rights to change the system configuration.

However, while viewing tank data using the system, it is essential that operators are able to view the data in an unobstructed manner without having to logon again and again as a result of session timeout. This is accomplished by identifying a certain computer as an "Operator

Workstation". If the Tankvision web pages are accessed from an operator workstation, the user can view the real-time tank information in an unobstructed manner once the user has logged onto the system.

To set or mange the operator workstation

Click

12.13.1 Set Operator Workstation

The user has to specify the IP address of the local machine to be used as operator workstation.

To set the operator workstation

1.

Endress+Hauser

Field

MAC address of this machine

Mark this machine as operator workstation

Description

Displays the MAC address of user's Personal Computer from where the operator is accessing the Tankvision system web pages.

Select the check box to mark the machine as the user’s or operator workstation.

2.

3.

4.

Enter the appropriate information in the relevant fields.

Click the Submit button.

After saving the settings, Tankvision displays a confirmation message.

An event is generated after setting the operator work station. The event details can be viewed in the Event or Alarm & Event overview.

185

The "System" menu Tankvision

12.13.2 Manage the Operator Workstation

The MAC address of the operators workstation that was set to configure the operator’s right can be deleted by this option.

To delete an operator workstation

1.

186

Column

Operator

Workstation MACs

Remove as Operator

Workstation

Description

The system displays the MAC addresses of the operator workstations.

The system displays the MAC address(es) of operators workstations that have to be removed. The IP addresses appear in this column after clicking on the right arrow.

2.

3.

Enter the appropriate information in the relevant fields.

Click the Submit button to remove the MAC address(es) of operator workstation(s).

Tankvision displays a confirmation screen as follows:

4.

5.

Click the OK button.

After saving the settings, Tankvision displays a confirmation message.

An event is generated after deleting the MAC address of an operator workstation. The event details can be viewed in the Event or Alarm & Event overview.

Endress+Hauser

Tankvision The "System" menu

12.14 System Diagnostics

The system diagnostic tools are intended for service operations only and should not be used for standard operations of the Tankvision system.

12.14.1 Diagnostic Data

Diagnostic data provides general status and diagnostic information like the number of times restarted and the temperature limits reached. This is a valuable tool to recognize unsafe conditions that could become a future failure.

Endress+Hauser 187

The "System" menu Tankvision

12.14.2 User Session Statistics

Provides useful information of users and user login activities. It allows to know which user logged in last via a Last Accessed Time stamp.

12.14.3 Service Codes

Service Codes is a service area that allows to execute predefined tasks by the operative system. As service codes are tasks like generate advanced diagnostic information, restart the unit, apply an historical archive clean up reset or execute a factory default settings reset.

188 Endress+Hauser

Tankvision The "System" menu

12.15 Uploads

12.15.1 Generic Uploads

Contains generic data to be uploaded from the Tankvision unit, e.g. diagnostic files

NXA82x_Uploads_Generic-Uploads

12.15.2 Convert Config. XML-File

12.15.3 Alarm Popup Agent (Win 32)

The Tankvision system raises various alarms pertaining to tank farm operations. The alarms are raised based on the measured and calculated tank data and the alarm settings. It is ideal for the operators to receive the alarm notification on their computer screen in the form of a pop up window.

To upload the installation files of the alarm pop up agent

1.

Endress+Hauser

2.

Click follows: on

NXA82x_Uploads

189

The "System" menu Tankvision

NXA82x_Uploads_AlarmPopup-Agent-Installer

4.

5.

3.

Click the AlarmPopup Agent (Win 32) link. Tankvision displays the File Download pop up window.

Click the Save button to download "APA_Setup.exe" to the operator’s local computer.

Run the setup to install the Alarm Popup Agent. The following screen is displayed:

6.

Enter the IP Address of the device where the Alarm Popup Agent should connect. After entering the IP Address click on Install.

190

7.

When setup completed successfully. The following screen is displayed.

Endress+Hauser

Tankvision The "System" menu

8.

Click on the Close button. Then the following screen will be displayed:

Endress+Hauser

Field

<Tank Name>

<Alarm Type>

<Alarm Status>

<Parameter>

<Value>

<Date>

Mute

ACK

Summary

The alarm pop up window remains on top of other windows on the Operator’s PC. The alarm pop up window cannot be closed or minimized unless all alarms are acknowledged.

Description

This field displays the tank name.

This field displays the alarm type.

This field displays the alarm status.

This field displays the alarm generating parameter.

This field displays the values of the corresponding parameter.

The system displays the date of the alarm.

The alarm popup window provides an audible alarm notification.

Click the Mute button to silence the audible alarm notification.

Click the Ack button to acknowledge the alarm.

Click the Summary button to view a summary of the alarm. The user can acknowledge the alarm from the summary of alarm overview screen.

Alarm Overview Description

Make sure that the specific condition is under control and click the appropriate alarm details from the Alarm Overview list. After selecting the appropriate alarm details, click the Ack

191

The "System" menu Tankvision button to acknowledge the alarm. This acknowledgement status is broadcast to all

Tankvision units.

Alternatively, click the Summary button to view the summary of alarms.

192

Field

Date

Event Type

Status

Ack Status

Element

Sub Type

Object

Value

Email

UserID

FGTagName

Event ID

Description

This column displays the date and time at which the alarm was raised.

This column displays whether the alarm that is raised is a system alarm.

This column indicates the status of the alarm in terms of Active or Inactive.

Active Alarm: The alarm is active and not yet acknowledge by an operator.

Inactive Alarm: The alarm is inactive and not acknowledged by an operator.

This column displays the acknowledgement status.

ACK: This term indicates that the alarm is acknowledged.

UNACK: This term indicates that the alarm is not acknowledged.

This column displays the name of the data element that has triggered the alarm. For example: level, temperature, pressure, etc. If the value of a data element deviates from the alarm set point value, the system raises an alarm.

This column displays the severity of alarm that is raised. Alarm types range from those with highest priority to those with least priority. Some alarm sub-types are: HH, HA, HL, LA, etc.

Reference: For more details on alarm sub-type, refer to "Types of Alarms" (→ ä 220).

This column displays the source of the alarm such as a tank, product, user or the Tankvision unit.

This column displays the measured value of the data element, due to which the alarm was raised, with its corresponding unit of measurement.

This column displays the e-mail delivery status: whether an e-mail was sent successfully to the configured mail server or not.

OK: This term signifies that the e-mail was sent successfully.

FAILED: This term signifies that the e-mail sending failed.

This column displays the user name, who has logged in to the system at the time of alarm generation.

This column displays the tag name of the Tankvision unit, which has raised the alarm.

The FGTagName is a host name of the server.

This column displays the event ID of the alarm. Every Tankvision unit has a unique numerical

ID.

Make sure that the specific condition is under control, and click the Ack button to acknowledge the alarm. This acknowledgement status is broadcast to all Tankvision units.

Endress+Hauser

Tankvision The "System" menu

Observe the following information!

• When more than one user acknowledges the alarm at the same time, the system will record the first user as the user who acknowledged the alarm and for all other users, the system will display the error message "Alarm has already been acknowledged".

• Whenever you acknowledge an alarm, the system raises and displays the appropriate event.

To uninstall the alarm pop up notification

1.

Use the uninstaller provided by the Alarm Popup Agent. Click Uninstall.

2.

When setup completed successfully the following screen is displayed:

Endress+Hauser 193

The "System" menu Tankvision

12.15.4 Printer Agent (Win 32)

Scheduled reports generated by the Tankvision system can be printed automatically without user intervention. This task is performed by the Printer Agent which can be uploaded to the computer from the Tankvision system.

To upload the Printer Agent

1.

on the screen as follows:

NXA82x_Global-Settings_Uploads_Printer-Agent-Installer

3.

4.

2.

Click the Printer Agent Installer (Win 32) link. Tankvision displays the File Download pop up window.

Click the Save button to download "PA_Setup.exe" to the operator’s local computer.

Run the "PA_Setup.exe" to install the Printer Agent.

194

5.

After the installation the Printer Agent will start automatically and asks the user to configure the printers.

Select 1 up to 3 printers where the reports shall be printed.

Endress+Hauser

Tankvision The "System" menu

12.15.5 Post Mortem Dumps

Post Mortem Dumps are used for advanced service operations only and should not used for normal operation.

12.15.6 OPC Server

An OPC Server is an application running on a PC serving data to an according OPC Client.

For details regarding operation and configuration of the OPC Server, refer to the document

BA01137G "Tankvision OPC Server".

NXA82x_Uploads_OPC-Server

12.15.7 BNR Setup (Backup and Restore)

The Backup and Restore (BNR) tool is an application running on a PC allowing the complete application and configuration of the NXA820/821/822 to be saved as safety copy to a hard drive.

NXA82x_Uploads_BNR-Setup

12.15.8 Service Interface

The Service Interface is an application running on a PC allowing the analysis of the field communication of the NXA820.

NXA82x_Uploads_Service-Interface

Endress+Hauser 195

The "System" menu

196

Tankvision

F310

F311

F312

F313

F314

F315

F316

F317

F501

F502

C503

F504

M505

C506

C507

C508

12.16 Device Status Codes

The Device Status Codes are intended only for service tasks. The should not be used for standard operations.

Diagnostic

Code

F101

Short Text Cause Possible Solution

F301

F302

F303

F304

F305

F306

F308

F309

F318

F319

F320

F321

F322

NXA 820 Conn.

Lost

Data Mem. Fault

LAN Fault

SYNC Fault

FPGA Error

NV Data Error

Order Code Error

Watchdog Error

FS Security Err

High CPU Load

Low Disk Space

Low RAM

Bad Thread

Reset by WD

CheckSum Error

Language Error

Access Cnfg Err

FPGA Config Err

RTC LowVolt Err

Time Read Err

Time maybe bad!

RTC Nvmgr Err

Database Fault

Not Configured

HART Tunneling

Subscrip. Store

Time Server

Field Scan Off

Interface Off

SYSTOOL Error

Unable to Communicate with NXA820

Failed to Detect or Initialize Data Flash

Memory

LAN Cable Disconnected or Failed

SYNC Link Cable Disconnected or Failed

Unable to access FPGA

The data in the NV memory does not match the RAM copy

The factory set order code is invalid, NXA is unable to startup

Software Watchdog Error

Security policy compromised due to file-system error

High CPU Utilization

Low Disk Space

Low RAM

Bad Thread Status

Hardware reset by WatchDog

CheckSum Error

Language Installation Error

Access Configuration Error: No machines registered for access fpga.conf file is corrupted or not available

Real Time Clock Battery Low voltage Detected

Real Time Clock Read Error

Time maintained by the RTC might be wrong

RTC could not access NV memory to store or retrive time

Database Failure

LAN Has Not Been Configured

Gauge Configuration In Progress

Subscription Store Cannot Be Found

To reprogram with proper SREC

The battery might have drained if the kit was off for a long duration

Check if i2cdriver started and working fine

Confirm and set the time on the kit

Check if nvmanager started and working fine

The fieldscan has been stopped

The hostlink interface has been stopped

SYSTOOL execution error

Endress+Hauser

Tankvision The "System" menu

12.17 Tankvision Outputs

To set or mange the Tankvision Outputs

Click

NXA82x_Tankvision-Outputs

12.17.1 SupplyCare Configuration

Configure the parameters that the Tank Scanner NXA820 provides when polled by

SupplyCare Enterprise.

To set or mange the SupplyCare Configuration

1.

Endress+Hauser

NXA82x_Tankvision-Outputs_SupplyCare-Configuration

Field

Tank

Time Stamp

Measurement Point

Configuration

Description

Select the tank from the drop-down list for which to configure the parameters that are provided for SupplyCare.

Either configure each tank individually or select the All Tanks check box to configure the same parameters for all tanks.

Choose between the SupplyCare Time Stamp and the Tank Scanner NXA820 Time Stamp for the provided parameters.

Configure the parameters for the tank(s) selected in the ’Tank’ field, that are provided when polled by SupplyCare.

2.

3.

4.

Enter the appropriate information in the relevant fields.

Click the Submit button to save the settings, or click the Reset to Default button to reset the screen to the default values.

After saving the settings, Tankvision displays a confirmation message, inculding the name of the .esp page which must be entered by the user in the Gateway configuration page of SupplyCare Enterprise.

An event is generated after setting the Tankvision Outputs. The event details can be viewed in the Event or Alarm & Event overview.

197

The "Reports" menu Tankvision

13 The "Reports" menu

In this chapter, you will learn how to generate reports.

To generate a report

1.

On the Navigation Tree, click the Reports header. Tankvision displays the screen as follows:

NXA82x_Reports_Report-Type

2.

Select the type of report you are going to configure from the list.

Depending on the type of Tankvision unit and the system configuration, the following report types may be available:

– System Configuration Report - Tank Scanner 3))

– System Configuration Report - Data Concentrator

3)

– System Configuration Report - Host Link

3)

– Product Transfer Report

– Systems Event Report

– Systems Alarm Report

– Inventory Report

– Delta Report

– Details Report

– Group Details Report

3.

4.

5.

On the following page, define which data are to be included into the report and which report template is to be used.

Click the Submit button.

After a couple of seconds Tankvision displays the report.

3) Depending on the Tankvision unit.

198 Endress+Hauser

Tankvision

13.1

Select NXA820 Configuration Details

The "Reports" menu

Endress+Hauser

Field

Alarm Settings

Trend Settings

Field Scan Settings

Description

Generate a report of the alarm settings.

Generate a report of the Trend settings.

Generate a report of the Field Scan settings.

Gauge Command Settings Generate a report of the Gauge Command settings.

Ambient Temperature Settings Generate a report of the Ambient Temperature settings.

Tank Shell Calculation Details

Tank General Details

Generate a report of the Tank Shell Calculation Details.

Generate a report of the Tank General Details.

Flow Calculation Details

Inventory Calculation Details

Select Report Template

Network Configuration

Local User Configuratoin

Field Scan Configuration (V1)

Tank Configuration specific to

NXA820

Water content calculation

Details

Floating Roof Details

Tank Capacity Details

Alarms Setting For Calculated

Data

Tank Calibration Settings

Generate a report of the Flow Calculation Details.

Generate a report of the Inventory Calculation Details.

Allows to select the report template to be used for the product transfer report.

Generate a report of the Network Configuration.

Generate a report of the Local User Configuration.

Generate a report of the Field Scan Configuration (V1).

Generate a report of the Tank Configuration specific to NXA820.

Generate a report of the Water content calculation Details.

Generate a report of the Floating Roof Details.

Generate a report of the Tank Capacity Details.

Generate a report of the Alarms Settings For Calculated Data.

Generate a report of the Tank Calibration Settings.

13.2

Select Product Transfer Details

199

The "Reports" menu Tankvision

Field

Select Report Template

Description

Selection list for installed Product Transfer report templates. If additional templates are installed user must select the wanted template. By default first template is selected.

13.3

Event Report

Field

Select Template

Start Date

End Date

Description

Allows to select the report template to be used for event report.

Define the start date (and time) for the event report.

Define the end date (and time) for the event report.

13.4

Alarm Report

Field

Select Template

Start Date

End Date

Alarm Type

NXA82x_Manage-Reports_Alarm-Report

Description

Allows to select the template to be used to generate the alarm report.

Define the start date (and time) for the alarm report.

Define the end date (and time) for the alarm report.

Allows to select the type of alarm to be included into the alarm report.

200 Endress+Hauser

Tankvision

13.5

Select Tanks For Tank Report

The "Reports" menu

Field

Select Tanks

Select Groups

Select Template

Start Date

End Date

Description

Allows to select the tanks to be included into the Tank report.

Allows to select the group of tanks to be included into the tank report.

Allows to select the template to be used to generate the tank report.

Define the start date (and time) for the tank report.

Define the end date (and time) for the tank report.

13.6

Select Tanks For Tank Detail Report

Endress+Hauser

Field

Select Tanks

Select Groups

Select Template

Description

Allows to select the tanks to be included into the Tank detail report.

Allows to select the group of tanks to be included into the tank detail report.

Allows to select the template to be used to generate the tank detail report.

201

The "Reports" menu

13.7

Select Tank Groups For Report

Tankvision

Field

Select Groups

Select Template

Description

Allows to select the group of tanks to be included into the tank group report.

Allows to select the template to be used to generate the tank group report.

13.8

Select Inventory Report

NXA82x_Reports_Inventory-Report

Field

Select Tanks

Select Groups

Select Template

Description

Allows to select the tanks to be included into the tank detail report.

Allows to select the group of tanks to be included into the tank group report.

Allows to select the template to be used to generate the tank group report.

Select Date and Time Allows to select the date and time from when the data on the report shall be generated.

202 Endress+Hauser

Tankvision The "Users" menu

14 The "Users" menu

The Tankvision system has an inbuilt authentication mechanism to prevent unauthorized access. The system identifies the user by a unique logon name and password. The system records all the activities performed by each user and allows only a specific number of users from each user type to be logged in at the same time. This can be configured in system settings by an authorized entity.

Each Tankvision unit has an option to confine user access rights data for local use within the unit or enable user access rights data for the central Tankvision unit thereby allowing the user to access all the units that are configured to the central Tankvision unit.

14.1

Manage Users

The Manage Users screen displays a list of all the users in the Tankvision system. It provides the necessary interface that allows the authorized persons to make changes in a user’s access rights to the Tankvision system, in particular:

• Add a new user

• Modify the user details

• Delete an existing User

To view the manage users screen

On the Navigation Tree, click the Users Header. (The number of users configured is displayed in brackets next to the Header’s name). Tankvision displays the screen as follows:

Field

User View

Group Rights

Description

The User View tab displays the list of users.

The Group Rights tab displays the details of access rights given to the respective users.

Click the Add button to add a new user.

Click the Modify button to modify the user details.

Click the Delete button to delete a user.

Endress+Hauser 203

The "Users" menu Tankvision

14.1.1 Adding a new user

The Tankvision system provides hierarchical user types and secure access to the system. The

Tankvision system allows the user to add a new user with specific user type rights.

To add a new user

1.

Click the Add button. Tankvision displays the screen as follows:

NXA82x_Manage-Users_Add-User

Field

User Logon Name

Description

Enter the user’s logon name. The data type is alphanumeric and is case sensitive.

User’s Actual Name Enter the full name of the user. This field will display data in text format.

Password Enter the user’s password. The data type is alphanumeric and case sensitive. It can be between 3 to 8 characters in length. All characters in this field will appear as masked for security reasons.

Confirm Password

User Type

E-Mail Address

Re-type the password for confirmation.

Select the appropriate user type from the drop down list. The types of users are predefined in terms of the user’s designation. They are used to group the users according to their access rights to the Tankvision system.

Enter the e-mail address of the user. The user will get all system alerts on this e-mail address.

2.

3.

4.

Enter the appropriate information in the relevant fields.

Click the Submit button to save the details of the user, or click the Cancel button to exit.

After saving the settings, Tankvision displays a confirmation message.

An event is generated after adding a new user. The event details can be viewed in the

Event or Alarm & Event overview.

204 Endress+Hauser

Tankvision

14.1.2 Modifying existing users’ details

This section explains how to modify the existing users’ details.

To modify the details of an existing user

1.

Select the appropriate User ID option on the User list view.

2.

Click the Modify button. Tankvision displays the screen as follows:

The "Users" menu

NXA82x_Manage-Users_Modify-User-Details

Field Description

User’s Actual Name Enter the full name of the user. This field will display data in text format.

Password

Confirm Password

User Type

Enter the user’s password. The data type is alphanumeric and case sensitive. It can be between 3 to 8 characters in length. All characters in this field will appear as masked for security reasons.

Re-enter the password for confirmation.

E-Mail Address

Select the appropriate user type from the drop down list. The types of users are predefined in terms of the user’s designation. They are used to group the users according to their access rights to the Tankvision system.

Type the e-mail address of the user. The user will get all system alerts on this e-mail address.

4.

5.

3.

6.

Alternatively, on the Navigation Tree, click the Users tab, and then click beside the

Users node. The Users node expands and displays the list of users. Click the appropriate user to modify the user details. The system displays the above screen Manage Users →

Users Details → Modify.

Enter the appropriate information in the relevant fields.

Click the Submit button to modify the details of the user, or click the Cancel button to exit.

After saving the settings, Tankvision displays a confirmation message.

An event is generated after modifying the details of a user. The event details can be viewed in the Event or Alarm & Event overview.

Endress+Hauser 205

The "Users" menu Tankvision

14.1.3 Deleting an Existing User

This section allows you to delete an existing user’s login information data, thereby denying access to any user who does not have a valid or enlisted user name and password.

To delete an existing user

1.

Select the appropriate User ID option on the User list view.

2.

Click the Delete button. Tankvision displays the following dialog box:

NXA82x_Users_Delete-User-Message

3.

4.

Click the OK button to delete the user, or click the Cancel button to exit.

After saving the settings, Tankvision displays a confirmation message.

An event is generated after deleting a user. The event details can be viewed in the

Event or Alarm & Event overview.

206 Endress+Hauser

Tankvision The "Users" menu

14.2

Managing the User Access Rights

The Tankvision system has predefined user group access rights, which may be used for managing the user’s access right. Each user belongs to a particular user group depending on his profile in the company. The users can access only those features of the system, which are available to their user group.

To manage the user access rights

1.

On the Navigation Tree, click the Users Header. (The number of users configured is displayed in brackets next to the Header’s name) Tankvision displays the screen as follows:

2.

Click the Group Rights tab on the Manage Users screen. Tankvision displays the screen as follows:

Endress+Hauser

Field

Logon Required

Active Guest Logon

Column

Data Element

NXA82x_Manage-User-Group-Access-Rights

Description

Select the check box to prompt the user to log on to access the Tankvision system.

Clear the check box to allow the user to access any feature of the Tankvision system without logging in to the system. This Field indicates whether the user needs to logon to the system to access the Tankvision functionality.

Select the check box to prompt the guest user to log on to access the Tankvision system.

Clear the check box to allow the guest user to access the features that are available to guests only. This Field indicates whether a third party or guest user needs to log on to access the Tankvision functionality.

Description

This column displays a list of Data Elements, which are accessible only to specific user groups. To obtain access to these elements, the user with valid access rights

(for example, supervisor/ technician) needs to allot access rights to the user group.

207

The "Users" menu

Column

Operator

Supervisor

Technician

Tankvision

Description

An operator performs day-to-day operations at the tank farm and can view refreshed data and alarm notifications. Select the appropriate check box to allow the operator group to access the relevant Data Element.

A supervisor configures and maintains the Tankvision system. He can view refreshed data and alarm notifications. Select the appropriate check box to allow the supervisor group to access the relevant Data Element.

A technician is a service person from Endress+Hauser who performs the initial setup and configuration of the Tankvision system. Select the appropriate check box to allow the technician group to access a particular Data Element.

Data Elements

File Access

Configuration Access

Change Tank Group

Settings

Description

Access to allow file upload or download e.g. Firmware or web page templates

Access to change configuration

Allows to add, modify and delete tank group settings for static and dynamic tank groups

Change Alarm Settings Allows to create, modify and delete alarm configurations

Allow Alarm Acknowledge Allows to acknowledge active alarms

Allow Tank Operations

Change Product Settings

Allows to change tank status, product contents and enter manual data operations

Allows to create, modify and delete products

Perform Product Transfer Allows to arm, start and stop product movements

Perform Gauge Commands Allows to issue, kill and schedule gauge commands

Change User Settings

View Trend and Change

Trend’s parameters

Perform Archive Export

View KPI Dashboard

Allows to add, modify and delete users, and modify user access rights

Allows to configure real time and historical trend, and start or stop the real time and historical trends

Allows the export of the archive.

Allows to view the KPI Dashboard.

3.

4.

5.

6.

7.

Alternatively, on the Navigation Tree, click the Users tab, and then click Users Access

Rights. The system displays the above screen Manage Users - Group Access Rights.

Enter the appropriate information in the relevant fields.

Click the Submit button to save the group access rights, or click the Cancel button to exit.

Click the Set To Default button to return to the default settings.

After saving the settings, Tankvision displays a confirmation message.

An event is generated after modifying user access rights. The event details can be viewed in the Event or Alarm & Event overview.

208 Endress+Hauser

Tankvision Historical Trend

15 Historical Trend

The Tankvision system collects data from the tanks and monitors the values using a trend.

A trend is a line graph which gives a pictorial representation of the recent changes in measured values over time. The historical trend is hosted in the NXA820 unit. It depicts the measured values and elements of a selected tank as a function of time in the form of a line chart.

The system has default settings which can be customized as required for each tank element.

The historical trend shows (unlike the real time trend) historical data which are stored in the

Tankvision unit. Up to 4 values can be plotted in one chart. For further information see "View

Historical Trend", → ä 157.

NXA82x_Historical-Trend-menu

On the Navigation Tree, click the Historical Trend header. Tankvision displays the screen as follows.

NXA82x_Historical-Trend_Select-Tank-or-Tank-Group

Select Tank or Tank Groups and Intervall which should be displayed and continue by clicking

Configure Pens. Tankvision displays the screen as follows:

Endress+Hauser

NXA82x_Historical-Trend_Configure-Pens

Click on View Historical Trend. Tankvision displays the Historical Trend as follows:

209

Historical Trend Tankvision

210

NXA82x_Historical-Trend_View

Refer to the "View Real Time Trend" section (→ ä 73) for the description of the above screen.

Endress+Hauser

Tankvision KPI Dashboards

16 KPI Dashboards

Key Performance Indicators (KPIs) are predefined, calculable, sensible and not financial test parameters that provide the user of Tankvision with information for the evaluation and analysis of executed processes.

Data from the archive data base of the Tank Scanner NXA820 is loaded (not applicable for the interface-only version) which is the calculation basis of the KPIs. The KPIs are calculated and graphically displayed.

16.1

Starting KPI Dashboards

NXA82x_Historical-Trend-menu

On the Navigation Tree, click the KPI Dashboard header. Tankvision displays a progress bar while retrieving data as follows.

NXA82x_KPI-Dashboards_Loading-required-data

The rest of the screen is locked while the progress bar is displayed.

16.2

Global Settings

1 2 3 4 5

Endress+Hauser

6

NXA82x_KPI-Dashboards_Overview

211

KPI Dashboards Tankvision

2

3

4

Pos.

Field Description

1 Select

Period

Dashboard Select the period for which the KPI data are displayed from the drop down list and click Refresh.

5

Dashboard Controls

Select KPI

KPI Graphic Area

Select Tanks/Groups and Free Stock

Click Fit to size to fit the KPI Dashboard in your browser window.

Select the appropriate KPI to be displayed.

The KPI Graphic Area includes a chart of the selected KPI for the selected Tanks/

Groups over the selected Dashboard Period.

Select the appropriate Tanks/Groups or Free Stock to be displayed.

As default, only the first tank in the list ist selected.

Not available for all KPIs.

6 Select Shown Time

Interval

Click and drag to select the time interval that is displayed in the KPI Graphic

Area.

Click Reset in the upper left corner of the KPI Graphic Area to reset the displayed period to default.

Not available for all KPIs.

16.3

Tank Turn Over KPI

The Tank Turn Over KPI indicates how often a tank is turned over during the selected period.

Select the Tank Turn Over KPI. Tankvision displays the screen as follows.

212

NXA82x_KPI-Dashboards_Tank-Turn-Over

To select the tanks to be displayed, select/clear the check boxes in the list on the right of the

KPI Graphic Area.

16.4

Safety Stock KPI

The Safety Stock KPI indicates how often the volume of a tank has undershot the "Safety

Stock Volume" during the selected period. The Safety Stock Volume Point is set by the TOV

LA alarm. Therefore it is necessary to set the LA alarm for each tank.

The Safety Stock KPI is calculated using the currently set LA alarm. Thus, the LA alarm can be set retroactively.

Select the Safety Stock KPI. Tankvision displays the screen as follows.

Endress+Hauser

Tankvision KPI Dashboards

NXA82x_KPI-Dashboards_Safety-Stock

To select the tanks to be displayed, select/clear the check boxes in the list on the right of the

KPI Graphic Area.

If the LA alarm is not set for one or more tanks, the following info panel is displayed listing all the tanks without a set LA alarm. Click OK to acknowledge.

NXA82x_KPI-Dashboards_Safety-Stock_Info-Panel

16.5

Free Stock KPI for Tanks

The Free Stock KPI for tanks indicates the IN STOCK values for each tank as well as the FREE

STOCK value relating to all tanks.

The Free Stock is the overall sum of the free capacities of all tanks (not just the selected tanks).

Select the Free Stock for Tanks KPI. Tankvision displays the screen as follows.

Endress+Hauser

NXA82x_KPI-Dashboards_Free-Stock-for-Tanks

To select the tanks and the Free Stock to be displayed, select/clear the check boxes in the list on the right of the KPI Graphic Area.

213

KPI Dashboards Tankvision

In the Select Shown Time Interval field, click and drag to select the time interval that is displayed in the KPI Graphic Area.

Click Reset in the upper left corner of the KPI Graphic Area to reset the displayed period to default

If the MAX TANK CAPACITY is not configured for one or more tanks, the following info panel is displayed listing all the tanks without a configured MAX TANK CAPACITY. These tanks are not included in the calculation of the Free Stock. Click OK to acknowledge.

NXA82x_KPI-Dashboards_Free-Stock-for-Tanks_Info-Panel

16.6

Free Stock KPI for Groups

The Free Stock KPI for groups indicates the IN STOCK values for each group as well as the

FREE STOCK values relating to each group.

The Free Stock for the group is the overall sum of the free capacities of all tanks contained in the group.

Select the Free Stock for Groups KPI. Tankvision displays the screen as follows.

214

NXA82x_KPI-Dashboards_Free-Stock-for-Groups

To select the groups and the Free Stocks to be displayed, select/clear the check boxes in the list on the right of the KPI Graphic Area.

In the Select Shown Time Interval field, click and drag to select the time interval that is displayed in the KPI Graphic Area.

Click Reset in the upper left corner of the KPI Graphic Area to reset the displayed period to default

16.7

Percentage of Products KPI

The Percentage of Products KPI shows the percental distribution of Products/Groups during the selected period.

Select the Percentage of Products KPI. Tankvision displays the screen as follows.

Endress+Hauser

Tankvision KPI Dashboards

NXA82x_KPI-Dashboards_Percentage-of-Products

The pie chart on the right displays the position in the KPI Graphic Area that the mouse cursor is currently pointing at.

Clicking into the KPI Graphic Area locks the position for the pie chart. Clicking one more time releases the position.

You can zoom in with double clicking into the KPI Graphic Area or by using the scroll wheel.

Zoom out with the scroll wheel or with the Reset button.

Choose between Bars and Points as display style of the KPI Graphic Area (Bars is default).

16.8

Errors

If, after starting KPI Dashboard, Cancel was clicked on the progress bar, Tankvision displays the following error.

Endress+Hauser

NXA82x_KPI-Dashboards_Data-Request-Error_Aborted-by-User

If no archive data are available for one or more tanks, Tankvision displays the following error listing the concenred tanks.

215

KPI Dashboards Tankvision

NXA82x_KPI-Dashboards_Data-Request-Error_Archival-Data

If KPI Dashboard is running and the Tank Scanner does not respond, Tankvision displays the following error.

NXA82x_KPI-Dashboards_Error_Invalid-Response

If KPI Dashboard is running and the connection to the Tank Scanner is lost (LAN error),

Tankvision displays the following error.

NXA82x_KPI-Dashboards_Error_LAN-Fault

216 Endress+Hauser

Tankvision The Alarm and Event Panel

17 The Alarm and Event Panel

17.1

Overview of the Alarm and Event Panel

The Alarm and Event Panel of the Tankvision system displays an overview of the Alarm and

Events generated by the system. The system will also pop up the message to the user in the local personal computer if an alarm pop up application is installed on that workstation.

17.1.1 Alarm Summary

Alarms:

Alarms are conditions pertaining to the functioning of the Tank or Tank elements. These conditions must be communicated to the user. The user may take the necessary actions based on the critical alarm displayed on the screen. These conditions are pre-defined by the user with valid access rights (for example, supervisor/ technician) while configuring a tank and the tank elements.

The Tankvision system is configured to raise various alarms based on measured data, calculated tank data, and alarm settings. The system continuously monitors the measured and calculated data and compares them with the preset alarm conditions such as Hold-off time and set point values. Whenever the value of a measured datum deviates from the set point value and remains deviated for a time span greater than or equal to the hold-off time, the system raises the appropriate alarm. The alarm will appear in the Alarm overview tab on the respective unit. The Operators receive the alarm notification on their computer screen in the form of a pop up window.

To view the alarm Summary

1.

Click the Alarm tab. Tankvision displays the "Alarm" information as follows:

Endress+Hauser

Field

Date

Event Type

Status

Ack Status

Element

Sub Type

Object

Value

Description

This column displays the date and time at which the alarm was raised.

This column indicates whether the alarm that is raised is a system alarm.

This column indicates the status of the alarm in terms of Active or Inactive.

Active Alarm: The alarm is active and not yet acknowledge by an operator.

Inactive Alarm: The alarm is inactive and not acknowledged by an operator.

This column indicates whether an alarm is acknowledged or not by an operator

ACK: The alarm is acknowledged.

UNACK: The alarm is not acknowledged.

This column indicates the name of the data element that has triggered the alarm. For example: level, temperature, pressure, etc. If the value of a data element deviates from the set point value the system raises an alarm.

This column indicates the severity of alarm that is raised. Alarm types range from those with highest priority to those with least priority. The examples for alarm sub- types are,

HH, HL. LA, etc.

This column indicates the source of the alarm such as a tank, product, user or a

Tankvision unit.

This column indicates the currently measured value of the data element, due to which the alarm was raised, with its corresponding unit.

217

The Alarm and Event Panel Tankvision

Field

Email

UserID

FGTagName

Event ID

Option

Description

This column indicates the e-mail delivery status: whether an e-mail was sent successfully to the configured mail server or not.

OK: The e-mail was successfully sent.

FAILED: The e-mail-sending failed.

This column indicates the name of the user which was logged in at the time when the alarm was generated.

This column indicates the tag name of the Tankvision unit which has raised the alarm.

The FGTagName is the host name of the server.

This column indicates the event ID of the alarm. Every Tankvision unit has a unique numerical ID.

This column allows the user to acknowledge an alarm if required. The user can acknowledge the alarm once he makes sure that the specific condition is under control.

This acknowledgement status is broadcast to all Tankvision units.

ACK: The ACK button appears when an alarm needs to be acknowledged.

A blank field appears when the alarm has already been acknowledged.

Reference: Refer to "Types of Alarms" (→ ä 220) and "Alarm Color Schemes" (→ ä 220).

Whenever you acknowledge an alarm, the system raises and displays the appropriate event.

17.1.2 Event Summary

Events:

Apart from alarms, the Tankvision system also generates various "system events". System events are generated for changes in the state of system or for certain actions carried out by users. Unlike alarms, events need not to be acknowledged by users. Examples of system events are configuration changes, Start Field Scan, Stop Field Scan, Alarm ACK, etc.

To view the event summary

1.

Click the Event tab. Tankvision displays the "Event" information as follows:

218

Field

Date

Event Type

Object

Email

User ID

FGTagName

Event ID

Description

This column displays the date and time at which the alarm was raised.

This column indicates whether the alarm that is raised is a system malfunction alarm or a change in system configuration.

This column indicates the source of the alarm such as a tank, product, user or a

Tankvision unit.

This column indicates the e-mail delivery status: whether an e-mail was sent successfully to the configured mail server or not.

OK: The e-mail was successfully sent.

FAILED: The e-mail-sending failed.

This column indicates the logon name of the user.

This column indicates the tag name of the Tankvision unit which has raised the event or alarm. The FGTagName is the host name of the server.

This column indicates the Identification (ID) numbers of the Tankvision units in concern.

Every Tankvision unit has a unique numerical ID.

Endress+Hauser

Tankvision The Alarm and Event Panel

17.1.3 Alarm and Event Summary

You can view the list of raised alarms as well as events in a single window. If an attribute is not related to that particular alarm or event, then the corresponding entry for the attribute is "N/A".

To view the alarm and event summary

1.

Click the Alarm & Event tab. Tankvision displays the "Alarm & Event" information as follows:

The attributes of the Alarm and Events Summary screen are described in "Alarm Summary"

(see above).

Endress+Hauser 219

The Alarm and Event Panel Tankvision

17.2

Types of Alarms

Alarm Sub-Types:

The Tankvision system raises different types of alarms depending on the value of a data element such as product level, temperature, pressure, etc. in comparison with the set point.

Different alarm types are described in the table below.

Sub Type Description

HH

HA

MF

LA

LL

CH

DF

FL

CO

TO

High High Alarm

High Alarm

Max Fill Alarm

Low Alarm

Low Low Alarm

Is Set off

Whenever the value of a data element rises above the HH set point and remains there for an interval greater than or equal to the hold-off time for the alarm.

Data Elements that set off alarms when they deviate from the predefined set point value, are as follows:

Product Level, Temperature, Pressure, Density, Product Secondary level,

Water level, Vapor pressure, Vapor temperature.

Whenever the value of a data element rises above the HA set point and remains there for an interval greater than or equal to the hold-off time for the alarm.

This alarm sub-type is similar to HH but with lower severity than HH.

The set point for HA is lower than the set point for HH.

Whenever the product level value rises above the MF set point and remains there for an interval greater than or equal to the hold-off time for the alarm.

Whenever the value of a data element falls below the LA set point and remains there for an interval greater than or equal to the hold-off time for the alarm.

Whenever the value of a data element falls below the LL set point and remains there for an interval greater than or equal to the hold-off time for the alarm.

This alarm sub-type is similar to LA but with higher severity than LA.

The set point for LL is lower than the set point for LA.

Change Alarm

Difference Alarm

Fail Alarm

Whenever the rate of change of the data element level increases above the

CH set point and remains above there for an interval greater than or equal to the hold-off time for the alarm.

This alarm is raised only when the tank is in the "Locked" status (→ ä 84).

Whenever the absolute value of the difference between product level and product secondary level increases above the DF set point and remains there for an interval greater than or equal to the hold-off time for the alarm.

Whenever the gauge status received from a gauge indicates that the gauge has failed.

Whenever the communication with a gauge fails due to a timeout error.

Gauge

Communication Error

Alarm

Time out / Age

Alarm

Whenever the data received from a gauge is too old.

17.3

Alarm Color Schemes

The Tankvision system highlights the alarms using different text and background colors to indicate the priority of each alarm as shown in the figure below.

220 Endress+Hauser

Tankvision

Background Color

Dark Green

Light Red

Yellow

White

Text Color

Bright Yellow

Bright Yellow

Red

Black

The Alarm and Event Panel

Indicates

An active and acknowledged alarm

An active and unacknowledged alarm

An inactive and unacknowledged alarm

An inactive and acknowledged alarmed

Endress+Hauser 221

The Alarm and Event Panel Tankvision

17.4

Acknowledging an Alarm

One of the important aspects of an alarm is alarm acknowledgement. As long as an alarm is not acknowledged, a new alarm of the same kind for the same tank is not generated, even if the related datum again crosses the configured set point. Therefore, a new alarm of the same type is generated only after the current alarm has become inactive and has been acknowledged by the user.

Alarm acknowledgment ensures that the alarm condition has been brought to the notice of operators. Alarms can be acknowledged from the Alarm summary displayed in the Alarm and Event Panel of the user interface or alarm pop up agent, or from a host system connected to the Tankvision system.

To acknowledge an alarm

1. Click the "ACK" button in the Option column.

When more than one user acknowledges the alarm at the same time, the system will record the first user as a user who acknowledged the alarm. For all other users, the system will display the error message “Alarm has already been acknowledged”.

Error Messages

1. "You Do Not Have Access Rights to Acknowledge Alarms!"

This message appears if you do not have authority to acknowledge an alarm. Only the user with valid access rights (for example, supervisor/ technician) can acknowledge an alarm.

222 Endress+Hauser

Tankvision Other Global Setting

18 Other Global Setting

In this chapter, you will learn how to:

• View and configure other Tankvision units’s global settings

The Tankvision system comprises various Tankvision subsystems, such as, NXA820,

NXA821 and NXA822. Each subsystem serves a specific functionality.

The system shows various Tankvision units in the domain network. In this system, the user can view other Tankvision units. The authorized user can also change the global configuration settings of other Tankvision units.

To view and configure other Tankvision unit’s global setting

1.

On the Navigation Tree, click the System header. The System Header expands as follows:

NXA82x_Menu_System-folded

2.

3.

The above figure displays the <Tankvision Subsystem>, viz, Tank Scanning Units

(NXA820), Data Concentrators (NXA821) and Host Links (NXA822). The Tank

Scanning Units, Data Concentrators, and Host Links consists of all the NXA820,

NXA821 and NXA822 units respectively in that domain network.

Click the adjacent to <Tankvision Subsystem>. Tankvision displays the screen as follows:

Endress+Hauser

NXA82x_Menu_System

4.

Click the <Unit Name>. Tankvision displays the global settings screen of the <Unit

Name>, which is as follows:

223

Other Global Setting Tankvision

NXA82x_Global-Settings-Screen-folded

5.

The user may view the global configuration settings, and edit the settings.

The system generates an event if the global settings are edited. The event details are displayed in the Event or Alarm & Event tab of that particular Tankvision unit, which is edited.

224 Endress+Hauser

Tankvision Comm DTM for FieldCare

19 Comm DTM for FieldCare

The NXA82x Comm DTM makes it possible to use the FieldCare for remote diagnosis and configuration of field devices. The Comm DTM connects automatically to the devices by sending the tank name to which the system must create a HART tunnel. The Comm DTM is downward compatible to older NXA82x firmware.

If you use older firmware than V01.05, the HART tunnel must be created manually; the setting of the Tank Name will be ignored.

NXA8xx COM DTM Screen Shot

Default password: hart

Endress+Hauser 225

Tankvision

Index

A

Add Gauge Map File

Modbus EIA485. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138

Sakura V1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143

Whessoe WM550 . . . . . . . . . . . . . . . . . . . . . . . . . . . 148

Alarm and Event Panel . . . . . . . . . . . . . . . . . . . . . . . 13, 217

Alarm and Event Summary . . . . . . . . . . . . . . . . . . . . . . 219

Alarm Color Schemes . . . . . . . . . . . . . . . . . . . . . . . . . . . 220

Alarm Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200

Alarm Summary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 217

Alarms

Acknowledging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222

Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220

Ambient Temperature Scan

Modbus EIA485. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137

Sakura V1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142

Whessoe WM550 . . . . . . . . . . . . . . . . . . . . . . . . . . . 147

Assign Product tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87

C

Calculated Data Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . 59

Calibrated Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54

Capacity Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

Comm DTM for FieldCare. . . . . . . . . . . . . . . . . . . . . . . . 225

Common Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Customer Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117

Additional Language Configuration . . . . . . . . . . . . 127

Base Language Configuration . . . . . . . . . . . . . . . . . 127

Configuration Store definition . . . . . . . . . . . . . . . . . 123

Configuration Store Details . . . . . . . . . . . . . . . . . . . 125

Customer Language Configuration . . . . . . . . . . . . . 127

Date and Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123

Default Language. . . . . . . . . . . . . . . . . . . . . . . . . . . . 121

Email Server Settings. . . . . . . . . . . . . . . . . . . . . . . . . 122

Printer Agent Configuration. . . . . . . . . . . . . . . . . . . 125

Site Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117

Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119

D

Data Archival . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153

Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153

Export . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156

View Archived Data . . . . . . . . . . . . . . . . . . . . . . . . . . 157

Data Concentrator NXA821 specific settings. . . . . . . . . 24

Designated use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Device Status Codes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196

Diagnostic Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187

Dipped Data tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68

Download Logo Image For Printer Agent. . . . . . . . . . . 182

Download Report Templates . . . . . . . . . . . . . . . . . . . . . 181

Download Report Templates For Printer Agent . . . . . 183

Downloads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181

E

Entis Host Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174

Environment Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . 134

Event Report. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200

226

Event Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218

F

Field Protocol

Modbus EIA485. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136

Sakura V1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141

Whessoe WM550 . . . . . . . . . . . . . . . . . . . . . . . . . . . 146

Field Scan

Modbus EIA485. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136

Sakura V1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141

Whessoe WM550 . . . . . . . . . . . . . . . . . . . . . . . . . . . 146

Floating Roof . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

Flow Calculation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

G

Gauge Commands

Schedule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69

Send . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71

Gauge Commands tab. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69

General Details tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64

H

HART command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

HART tunnel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 225

Historical Trend. . . . . . . . . . . . . . . . . . . . . . . . . . . . 157, 209

Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159

Home Page. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Host Link . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161

Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161

Start/Stop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180

Host Link NXA822 specific settings . . . . . . . . . . . . . . . . . 24

Hybrid Tank Measurement System. . . . . . . . . . . . . . . . . . 52

I

Icons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Inventory Calculation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

Inventory Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202

IT security. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

K

KPI Dashboards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211

Errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215

Free Stock KPI for Groups. . . . . . . . . . . . . . . . . . . . . 214

Free Stock KPI for Tanks. . . . . . . . . . . . . . . . . . . . . . 213

Global Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211

Percentage of Products KPI . . . . . . . . . . . . . . . . . . . 214

Safety Stock KPI. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212

Tank Turn Over KPI. . . . . . . . . . . . . . . . . . . . . . . . . . 212

L

Logging in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

M

MAC Address. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152

Manage Field Scan Configuration

Modbus EIA485. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138

Sakura V1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144

Endress+Hauser

Tankvision

Whessoe WM550 . . . . . . . . . . . . . . . . . . . . . . . . . . . 149

Manage Users . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203

Manual Data tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

Measured Data Alarm. . . . . . . . . . . . . . . . . . . . . . . . . . . . 57

Menu

Alarm Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56

Customized Groups . . . . . . . . . . . . . . . . . . . . . . . . . . 105

Gauge Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91

Reports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198

System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116

Tank Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

Transfers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114

Users . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203

Modbus Coil Map For Alarm Status . . . . . . . . . . . . . . . 162

Modbus Register Configuration for Gauge

Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164

Modbus Register Map for Parameters . . . . . . . . . . . . . 167

MODBUS Serial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172

Modbus TCP Configuration . . . . . . . . . . . . . . . . . . . . . . 173

Monitoring Configuration . . . . . . . . . . . . . . . . . . . . 19, 132

N

Navigation Tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Network Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . 129

Network Node Detection. . . . . . . . . . . . . . . . . . . . . . 18, 131

Network Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16, 128

Tankvision Network Configuration . . . . . . . . . . . . . 128

O

Operating Screens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

Operator Workstation Settings . . . . . . . . . . . . . . . . . . . 185

P

Product Tank Group Details

Graphical View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102

Tabular View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103

Product Tank Groups. . . . . . . . . . . . . . . . . . . . . . . . . . . . 101

Product Transfer Group Details

Graphical View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115

Tabular View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115

Product Transfer Life Cycle. . . . . . . . . . . . . . . . . . . . . . . . 75

Product Transfer Report . . . . . . . . . . . . . . . . . . . . . . . . . 199

Product Transfer Report tab. . . . . . . . . . . . . . . . . . . . . . . 88

Product Transfer Status . . . . . . . . . . . . . . . . . . . . . . . . . . 78

Product Transfer tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75

Products

Adding, Modifying and Deleting . . . . . . . . . . . . . . . . 91

Mass & Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98

Reference Density Calculation (RDC) . . . . . . . . . . . . 95

Sediment & Water . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96

Vapor Calculation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99

Volume Correction Factor (VCF) . . . . . . . . . . . . . . . . 94

Weight & Measure. . . . . . . . . . . . . . . . . . . . . . . . . . . 100

R

Real Time Trend tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73

S

Safety icons. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Endress+Hauser

Service Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188

Service Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140

Shell Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

Spot Temperature tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66

Start/Stop a Field Scan

Modbus EIA485. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139

Sakura V1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145

Whessoe WM550 . . . . . . . . . . . . . . . . . . . . . . . . . . . 150

Subscription Store definition . . . . . . . . . . . . . . . . . . . . . . . 21

SupplyCare Configuration . . . . . . . . . . . . . . . . . . . . . . . 197

Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

System Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187

System Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

T

Tank Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160

Tank Calculator tab. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90

Tank Capacity Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

Tank Detail Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201

Tank Details screen. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63

Tank Group Details

Graphical View. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111

Real Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110

Tabular View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112

Tank Groups

Delete . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109

Dynamic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107

Modify. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108

Static . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106

Tank Groups Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202

Tank Picture. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

Tank Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201

Tank Scanner NXA820 specific settings . . . . . . . . . . . . . 23

Tank Scanner Unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160

Tank Status Change Matrix . . . . . . . . . . . . . . . . . . . . . . . . 84

Tank Status Indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85

Tank Status tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84

Tankvision Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197

TCT XML file contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

Time Server Settings . . . . . . . . . . . . . . . . . . . . . . . . . 19, 132

Trend Global Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . 135

U

Uploads. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189

Alarm Popup Agent (Win 32) . . . . . . . . . . . . . . . . . 189

BNR Setup (Backup and Restore) . . . . . . . . . . . . . . 195

Convert Config. XML-File. . . . . . . . . . . . . . . . . . . . . 189

Generic Uploads. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189

OPC Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195

Post Mortem Dumps . . . . . . . . . . . . . . . . . . . . . . . . . 195

Printer Agent (Win 32) . . . . . . . . . . . . . . . . . . . . . . 194

Service Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195

User Access Rights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207

User Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

User Session Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . 188

W

W&M Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151

W&M Seal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151

227

Tankvision

Access Configuration . . . . . . . . . . . . . . . . . . . . . . . . . 152

W+M systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

Water Content. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

228 Endress+Hauser

Tankvision

Endress+Hauser 229

71241952

www.addresses.endress.com

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Key Features

  • Real-time tank level monitoring and data acquisition
  • Inventory management and optimization
  • Alarm and event management
  • Data logging and reporting
  • Supports multiple tank types and protocols
  • User-friendly interface for easy operation
  • Advanced data analysis and trending tools
  • Remote access and monitoring capabilities

Related manuals

Frequently Answers and Questions

What are the benefits of using the Tankvision system?
The Tankvision system provides numerous benefits, including improved inventory accuracy, reduced risk of overfills and spills, enhanced operational efficiency, and better decision-making based on real-time data.
What types of tanks can the Tankvision system monitor?
The Tankvision system can monitor a wide range of tank types, including above-ground and underground tanks, horizontal and vertical tanks, single- and double-walled tanks, and tanks with various shapes and sizes.
How does the Tankvision system communicate with tank sensors?
The Tankvision system communicates with tank sensors using various protocols, including Modbus, HART, and proprietary protocols. This allows for seamless integration with a wide range of sensor types and manufacturers.
What types of data does the Tankvision system collect?
The Tankvision system collects a comprehensive range of data from tank sensors, including level, temperature, pressure, volume, and other parameters. This data is stored in a central database for easy access and analysis.
How can I access and analyze the data collected by the Tankvision system?
The Tankvision system provides a user-friendly interface for accessing and analyzing data. Users can view real-time data, historical trends, and generate reports to gain insights into tank operations and inventory status.