AMOS-800 FCC Test Re..

RV-1302021
Neutron Engineering Inc.
FCC Test Report
Mar. 05, 2013
1301030
IPC
AMOS-800XXXXXXX; AMOS800XXXXXX-T
(“X” can be any alphanumeric character or
blank for marketing purpose)
Issued Date
Project No.
Equipment
Model Name
:
:
:
:
Applicant
Address
: VIA Technologies, Inc.
: 1F, 531, Zhongzheng Rd. Xindian District,
New Taipei City 231 Taiwan
Tested by: Neutron Engineering Inc. EMC Laboratory
Date of Receipt: Jan. 04, 2013
Date of Test: Jan. 04, 2013 ~ Feb. 26, 2013
Te s t i n g E n g i n e e r :
(Kener Wu)
Technical Manager :
(Jeff Yang)
Authorized Signatory :
(Andy Chiu)
Neutron Engineering Inc.
B1, No. 37, Lane 365, YangGuang St.,
NeiHu District 114, Taipei, Taiwan.
TEL: +886-2-2657-3299
FAX: +886-2-2657-3331
Report No.: NEI-FCCE-1-1301030
Page 1 of 36
Neutron Engineering Inc.
RV-1302021
Declaration
Neutron represents to the client that testing is done in accordance with standard procedures as applicable
and that test instruments used has been calibrated with the standards traceable to National Measurement
Laboratory (NML) of R.O.C., or National Institute of Standards and Technology (NIST) of U.S.A.
Neutron's reports apply only to the specific samples tested under conditions. It is manufacture’s
responsibility to ensure that additional production units of this model are manufactured with the identical
electrical and mechanical components. Neutron shall have no liability for any declarations, inferences or
generalizations drawn by the client or others from Neutron issued reports.
Neutron’s reports must not be used by the client to claim product endorsement by the authorities or any
agency of the Government.
This report is the confidential property of the client. As a mutual protection to the clients, the public and
Neutron-self, extracts from the test report shall not be reproduced except in full with Neutron’s authorized
written approval.
Neutron’s laboratory quality assurance procedures are in compliance with the ISO Guide 17025
requirements, and accredited by the conformity assessment authorities listed in this test report.
Limitation
For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this
test report is (are) included in the conformity assessment authorities acceptance respective.
Report No.: NEI-FCCE-1-1301030
Page 2 of 36
Neutron Engineering Inc.
Table of Contents
RV-1302021
Page
REPORT ISSUED HISTORY
4
1 . CERTIFICATION
5
2 . SUMMARY OF TEST RESULTS
6
2.1 TEST FACILITY
7
2.2 MEASUREMENT UNCERTAINTY
7
3 . GENERAL INFORMATION
8
3.1 GENERAL DESCRIPTION OF EUT
8
3.2 DESCRIPTION OF TEST MODES
9
3.3 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 10
3.4 DESCRIPTION OF SUPPORT UNITS
4 . EMC EMISSION TEST
11
12
4.1 CONDUCTED EMISSION TEST
4.1.1 LIMITS
4.1.2 MEASUREMENT INSTRUMENTS LIST
4.1.3 TEST PROCEDURE
4.1.4 DEVIATION FROM TEST STANDARD
4.1.5 TEST SETUP
4.1.6 EUT OPERATING CONDITIONS
4.1.7 TEST RESULTS
12
12
12
13
13
13
14
15
4.2 RADIATED EMISSION TEST
4.2.1 LIMITS
4.2.2 MEASUREMENT INSTRUMENTS LIST
4.2.3 TEST PROCEDURE
4.2.4 DEVIATION FROM TEST STANDARD
4.2.5 TEST SETUP
4.2.6 EUT OPERATING CONDITIONS
4.2.7 TEST RESULTS-BELOW 1 GHZ
4.2.8 TEST RESULTS-ABOVE 1 GHZ
19
19
20
21
22
22
22
23
27
5 . EUT TEST PHOTO
Report No.: NEI-FCCE-1-1301030
31
Page 3 of 36
Neutron Engineering Inc.
RV-1302021
REPORT ISSUED HISTORY
Revised Version No.
RV-1302021
Description
Initial Issue.
Re-defined model names.
Report No.: NEI-FCCE-1-1301030
Issued Date
Feb. 26, 2013
Mar. 05, 2013
Page 4 of 36
Neutron Engineering Inc.
RV-1302021
1. CERTIFICATION
E q u i p m e n t : IPC
Brand Name : VIA
Model Name : AMOS-800XXXXXXX; AMOS800XXXXXX-T (“X” can be any alphanumeric
character or blank for marketing purpose)
A p p l i c a n t : VIA Technologies, Inc.
Date of Test : Jan. 04, 2013 ~ Feb. 26, 2013
S t a n d a r d s : FCC Part 15, Subpart B: 2012 Class B
ICES-003 Issue 5: 2012 Class B
CAN/CSA CISPR 22-10 Class B
CISPR 22: 2008 Class B
ANSI C63.4-2009
The above equipment has been tested and found compliance with the requirement of the relative
standards by Neutron Engineering Inc. EMC Laboratory.
The test data, data evaluation, and equipment configuration contained in our test report (Ref No.
NEI-FCCE-1-1301030) were obtained utilizing the test procedures, test instruments, test sites that
has been accredited by the Authority of NVLAP and TAF according to the ISO-17025 quality
assessment standard and technical standard(s).
Report No.: NEI-FCCE-1-1301030
Page 5 of 36
RV-1302021
Neutron Engineering Inc.
2. SUMMARY OF TEST RESULTS
Test procedures according to the technical standards:
Emission
Standard
Test Item
FCC Part 15,
Conducted emission
Subpart B: 2012
ICES-003 Issue 5: 2012 Radiated emission Below 1 GHz
CAN/CSA CISPR 22-10
Radiated emission Above 1 GHz
CISPR 22: 2008
Limit
Judgment
Class B
PASS
Class B
PASS
Class B
PASS
Remark
NOTE (2)
NOTE:
(1) ”N/A” denotes test is not applicable in this Test Report.
(2) If the EUT’s max operating frequency does not exceed 108 MHz, the test will not be performed.
Report No.: NEI-FCCE-1-1301030
Page 6 of 36
RV-1302021
Neutron Engineering Inc.
2.1 TEST FACILITY
The test facilities used to collect the test data in this report:
Conducted emission Test:
C03: B1, No. 37, Lane 365, YangGuang St., NeiHu District 114, Taipei, Taiwan.
Radiated emission Test (Below 1 GHz):
OS01: (VCCI RN: R-2829; FCC RN: 95335; FCC DN: TW1010)
No.132-1, Ln. 329, Sec. 2, Balian Rd., Xizhi Dist., New Taipei City 221, Taiwan (R.O.C.)
Radiated emission Test (Above 1 GHz):
CB08: (VCCI RN: G-91; FCC RN: 614388; FCC DN: TW1054; IC Assigned Code: 4428C-1)
1F., No. 61, Ln. 77, Sing-ai Rd., Neihu Dist., Taipei City 114, Taiwan (R.O.C.)
2.2 MEASUREMENT UNCERTAINTY
The measurement uncertainty is not specified by FCC/ Industry Canada rules and for
reference only.
The reported uncertainty of measurement y ± U,where expended uncertainty U is based on a
standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of
approximately 95%.
The measurement instrumentation uncertainty considerations contained in CISPR 16-4-2.
A. Conducted emission test:
Test Site
Measurement Frequency Range
C03
150 kHz ~ 30 MHz
B. Radiated emission test:
Measurement Frequency
Test Site
Range
30 MHz ~ 200 MHz
30 MHz ~ 200 MHz
OS01
200 MHz ~ 1, 000 MHz
200 MHz ~ 1, 000 MHz
Test Site
Item
CB08
Radiated
emission at
3m
Ant.
H/V
V
H
V
H
Measurement Frequency Range
30 - 200MHz
200 - 1000MHz
Horizontal
Polarization
1 - 18GHz
18 - 40GHz
30 - 200MHz
200 - 1000MHz
Vertical
Polarization
1 - 18GHz
18 - 40GHz
U,(dB)
1.94
NOTE
U,(dB)
NOTE
2.86
2.56
2.88
2.98
Uncertainty
3.35 dB
3.11 dB
3.97 dB
4.01 dB
3.22 dB
3.24 dB
4.05 dB
4.04 dB
NOTE
Our calculated Measurement Instrumentation Uncertainty is shown in the tables above.
These are our Ulab values in CISPR 16-4-2 terminology.
Since Table 1 of CISPR 16-4-2 has values of measurement instrumentation uncertainty,
called UCISPR, as follows:
Conducted Disturbance (mains port) – 150 kHz – 30 MHz : 3.6 dB
Radiated Disturbance (electric field strength on an open area test site or alternative test
site) – 30 MHz – 1000 MHz : 5.2 dB
It can be seen that our Ulab values are smaller than UCISPR.
Report No.: NEI-FCCE-1-1301030
Page 7 of 36
Neutron Engineering Inc.
RV-1302021
3. GENERAL INFORMATION
3.1 GENERAL DESCRIPTION OF EUT
Equipment
IPC
Brand Name
VIA
AMOS-800XXXXXXX; AMOS800XXXXXX-T (“X” can be
Model Name
any alphanumeric character or blank for marketing purpose)
OEM Brand/Model Name N/A
Models’ differences between each other only the changes of
model name which do not affect the EMI performance.
Model Difference
Model AMOS-800 was used for final testing and collecting
test data included in this report.
The EUT is an IPC.
Based on the application, features, or specification exhibited
in User's Manual, the EUT is considered as an
Product Description
ITE/Computing Device. More details of EUT technical
specification, please refer to the User's Manual.
Power Source
DC Voltage supplied from External Power Supply.
1. EUT: I/P: DC 5V 2A
Power Rating
2. External Power Supply: Please refer to Products
Covered.
Connecting I/O Port(s)
Please refer to the User's Manual
1 * CPU: Freescale, ARM Cortex-A8 i.MX537, 800 MHz
1 * microSD Card: Transcend, 4 GB
1 * External Power Supply optional:
(1) FSP GROUP INC., FSP010-DWDA1
Products Covered
I/P: AC 100-240V 0.4A 50-60Hz / O/P: DC 5.0V 2.0A
(MAX)
(2) Asian Power Devices Inc., WA-15C05FU
I/P: AC 100-240V 50-60Hz 0.5A(0,5A) Max. / O/P:
DC 5V 3A
EUT Modification(s)
N/A
Note:
1. For a more detailed features description, please refer to the manufacturer’s specifications or the User's
Manual.
Report No.: NEI-FCCE-1-1301030
Page 8 of 36
RV-1302021
Neutron Engineering Inc.
3.2 DESCRIPTION OF TEST MODES
To investigate the maximum EMI emission characteristics generates from EUT, the test system
was pre-scanning tested base on the consideration of following EUT operation mode or test
configuration mode which possible have effect on EMI emission level. Each of these EUT
operation mode(s) or test configuration mode(s) mentioned above was evaluated respectively.
Pretest Test Mode
Description
Mode 1
FULL SYSTEM HDMI 1920*1080/60Hz (ADAPTER: WA-15C05FU)
Mode 2
FULL SYSTEM D-SUB 1680*1050/60Hz (ADAPTER: WA-15C05FU)
Mode 3
FULL SYSTEM D-SUB 1680*1050/60Hz (ADAPTER: FSP010-DWDA1)
Conducted emission test
Final Test Mode
Description
Mode 2
FULL SYSTEM D-SUB 1680*1050/60Hz (ADAPTER: WA-15C05FU)
Mode 3
FULL SYSTEM D-SUB 1680*1050/60Hz (ADAPTER: FSP010-DWDA1)
Radiated emission test
Final Test Mode
Description
Mode 2
FULL SYSTEM D-SUB 1680*1050/60Hz (ADAPTER: WA-15C05FU)
Mode 3
FULL SYSTEM D-SUB 1680*1050/60Hz (ADAPTER: FSP010-DWDA1)
Report No.: NEI-FCCE-1-1301030
Page 9 of 36
RV-1302021
Neutron Engineering Inc.
3.3 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED
C-1
C-2
Remote
System
C-3
C-9
E-1 EUT
E-2 Monitor
E-9
Micro SD
E-8 Modem*3
C-8
E-7 Printer
C-4
E-3 Keyboard
C-5
E-4
Mouse
C-6
C-7
E-5
Headset
E-6 Mp3
C-1 RJ-45 Cable
C-2 D-Sub Cable
C-3 HDMI Cable
C-4 USB Cable
C-5 USB Cable
C-6 Audio Cable*2
C-7 Audio Cable
C-8 USB Cable
C-9 RS232 Cable*3
Report No.: NEI-FCCE-1-1301030
Page 10 of 36
RV-1302021
Neutron Engineering Inc.
3.4 DESCRIPTION OF SUPPORT UNITS
The EUT has been tested as an independent unit together with other necessary accessories or
support units. The following support units or accessories were used to form a representative test
configuration during the tests.
Item
Equipment
Mfr/Brand
Model/Type No.
FCC ID
Series No.
Note
E-1
IPC
24” LCD
Monitor
USB K/B
VIA
AMOS-800
DOC
N/A
EUT
DELL
U2410f
DOC
CN-OJ257M-72872-09J-067L
DELL
L50U
DOC
N/A
DELL
MS111-L
DOC
CN-09RRC7-44751-17J-OH1F
CJ
CJ-323
N/A
N/A
DELL
HV04T
DOC
95NY781
HP
VCVRA-1004
DOC
CN17511HHK
ACEEX
DM-1414V
DOC
8041708
Transcend
N/A
N/A
N/A
E-2
E-3
E-4
E-5
E-6
E-7
E-8
E-9
USB Mouse
Compact
Earphone
Mic
USB
Flash/MP3
Player
Printer
Modem
Micro SD
Card
Item
Shielded Type
Ferrite Core
Length
C-1
NO
NO
10.0M
C-2
YES
YES
1.8M
C-3
YES
NO
1.7M
C-4
YES
NO
1.7M
C-5
YES
NO
1.7M
C-6
NO
NO
1.7M
C-7
NO
NO
1.7M
C-8
YES
NO
1.7M
C-9
YES
NO
1.7M
Note
Note:
(1) The support equipment was authorized by Declaration of Conformity (DOC).
Report No.: NEI-FCCE-1-1301030
Page 11 of 36
RV-1302021
Neutron Engineering Inc.
4. EMC EMISSION TEST
4.1 CONDUCTED EMISSION TEST
4.1.1 LIMITS (FREQUENCY RANGE 150 KHZ-30MHZ)
Class A (dBuV)
Class B (dBuV)
FREQUENCY
(MHz)
Quasi-peak
Average
Quasi-peak
Average
0.15 - 0.5
79.00
66.00
66 - 56 *
56 - 46 *
0.50 - 5.0
73.00
60.00
56.00
46.00
73.00
60.00
60.00
50.00
5.0 - 30.0
NOTE:
(1) The tighter limit applies at the band edges.
(2) The limit of " * " marked band means the limitation decreases linearly with the logarithm of the
frequency in the range.
(3) The test result calculated as following:
Measurement Value = Reading Level + Correct Factor
Correct Factor = Insertion Loss + Cable Loss + Attenuator Factor(if use)
Margin Level = Measurement Value – Limit Value
4.1.2 MEASUREMENT INSTRUMENTS LIST
Item Kind of Equipment
Manufacturer
Type No.
Serial No.
Calibrated until
1
TWO-LINE
V-NETWORK
R&S
ENV216
101051
Jun. 13, 2013
2
Test Cable
TIMES
LMR-400
3
EMI Test Receiver
R&S
ESCI
SR03_C_01&
02
100080
N/A
N/A
02
Sep. 18, 2013
N/A
N/A
06
Jun. 02, 2013
EMCO
3825/2
EZ_EMC
(Version NB-03A)
9605-2539
Sep. 04, 2013
N/A
N/A
4
5
6
7
50Ω BNC TYPE
Terminator
50Ω BNC TYPE
Terminator
LISN
Measurement
Software
EZ
Aug. 16, 2013
Mar. 13, 2013
Remark: “N/A” denotes No Model Name, No Serial No. or No Calibration specified.
Report No.: NEI-FCCE-1-1301030
Page 12 of 36
RV-1302021
Neutron Engineering Inc.
4.1.3 TEST PROCEDURE
a. The EUT was placed 0.8 meters from the horizontal ground plane with EUT being connected
to the power mains through a line impedance stabilization network (LISN). All other support
equipments powered from additional LISN(s). The LISN provide 50 Ohm/ 50uH of coupling
impedance for the measuring instrument.
b. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back
and forth in the center forming a bundle 30 to 40 cm long.
c. I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the
cable may be terminated, if required, using the correct terminating impedance. The overall
length shall not exceed 1 m.
d. LISN at least 80 cm from nearest part of EUT chassis.
e. For the actual test configuration, please refer to the related Item –EUT Test Photos.
NOTE:
a. Reading in which marked as Peak, QP or AVG means measurements by using are Quasi-Peak or
Average Mode with Detector BW=9 kHz (6 dB Bandwidth).
b. All readings are Peak Mode value unless otherwise stated QP or AVG in column of Note. If the
Peak or QP Mode Measured value compliance with the QP Limits and lower than AVG Limits, the
EUT shall be deemed to meet both QP & AVG Limits and then only Peak or QP Mode was
measured, but AVG Mode didn‘t perform.
4.1.4 DEVIATION FROM TEST STANDARD
No deviation
4.1.5 TEST SETUP
Vertical Reference Ground Plane
40 cm
EUT
Test Receiver
80 cm
LISN
Horizontal Reference Ground Plane
Report No.: NEI-FCCE-1-1301030
Page 13 of 36
Neutron Engineering Inc.
RV-1302021
4.1.6 EUT OPERATING CONDITIONS
The EUT exercise program used during radiated and/or conducted emission measurement was
designed to exercise the various system components in a manner similar to a typical use.
As the keyboard and mouse are strictly input devices, no data is transmitted to (from) them during
test. They are, however, continuously scanned for data input activity.
Report No.: NEI-FCCE-1-1301030
Page 14 of 36
Neutron Engineering Inc.
RV-1302021
4.1.7 TEST RESULTS
E.U.T
Temperature
Test Voltage
Test Mode
IPC
Model Name
AMOS-800
24°C
Relative Humidity
48%
AC 120V/60Hz
FULL SYSTEM D-SUB 1680*1050/60Hz (ADAPTER: WA-15C05FU)
Phase: Line
Report No.: NEI-FCCE-1-1301030
Page 15 of 36
Neutron Engineering Inc.
E.U.T
Temperature
Test Voltage
Test Mode
RV-1302021
IPC
Model Name
AMOS-800
24°C
Relative Humidity
48%
AC 120V/60Hz
FULL SYSTEM D-SUB 1680*1050/60Hz (ADAPTER: WA-15C05FU)
Phase: Neutral
Report No.: NEI-FCCE-1-1301030
Page 16 of 36
RV-1302021
Neutron Engineering Inc.
E.U.T
Temperature
Test Voltage
Test Mode
IPC
Model Name
AMOS-800
24°C
Relative Humidity
48%
AC 120V/60Hz
FULL SYSTEM D-SUB 1680*1050/60Hz (ADAPTER: FSP010-DWDA1)
Phase: Line
Report No.: NEI-FCCE-1-1301030
Page 17 of 36
RV-1302021
Neutron Engineering Inc.
E.U.T
Temperature
Test Voltage
Test Mode
IPC
Model Name
AMOS-800
24°C
Relative Humidity
48%
AC 120V/60Hz
FULL SYSTEM D-SUB 1680*1050/60Hz (ADAPTER: FSP010-DWDA1)
Phase: Neutral
Report No.: NEI-FCCE-1-1301030
Page 18 of 36
RV-1302021
Neutron Engineering Inc.
4.2 RADIATED EMISSION TEST
4.2.1 LIMITS
Below 1 GHz
FREQUENCY
(MHz)
30 - 230
230 - 1000
Class A (at 10m)
dBuV/m
40
47
Class B (at 10m)
dBuV/m
30
37
NOTE:
(1) The limit for radiated test was performed according to as following:
FCC Part 15, Subpart B: 2012; ICES-003 Issue 5: 2012; CAN/CSA-CISPR 22-10;
CISPR 22: 2008.
(2) The tighter limit applies at the band edges.
(3) Emission level (dBuV/m) = 20log Emission level (uV/m).
(4) The test result calculated as following:
Measurement Value = Reading Level + Correct Factor
Correct Factor = Antenna Factor + Cable Loss - Amplifier Gain(if use)
Margin Level = Measurement Value - Limit Value
Above 1 GHz
FREQUENCY
(MHz)
Above 1000
FREQUENCY
(MHz)
Above 1000
Class A (dBuV/m) (at 3m)
PEAK
AVERAGE
80
60
Class B (dBuV/m) (at 3m)
PEAK
AVERAGE
74
54
Class A (dBuV/m) (at 10m)
PEAK
AVERAGE
69.5
49.5
NOTE:
(1) The limit for radiated test was performed according to as following:
FCC Part 15, Subpart B: 2012; ICES-003 Issue 5: 2012.
(2) The tighter limit applies at the band edges.
(3) Emission level (dBuV/m) = 20log Emission level (uV/m).
3m Emission level = 10m Emission level + 20log(10m/3m).
(4) The test result calculated as following:
Measurement Value = Reading Level + Correct Factor
Correct Factor = Antenna Factor + Cable Loss - Amplifier Gain(if use)
Margin Level = Measurement Value - Limit Value
FREQUENCY RANGE OF RADIATED MEASUREMENT (FOR UNINTENTIONAL RADIATORS)
Highest frequency generated or Upper
frequency of measurement used in the device
Range (MHz)
or on which the device operates or tunes
(MHz)
Below 1.705
30
1.705 - 108
1000
108 - 500
2000
500 - 1000
5000
5th harmonic of the highest frequency or
Above 1000
40 GHz, whichever is lower
Report No.: NEI-FCCE-1-1301030
Page 19 of 36
RV-1302021
Neutron Engineering Inc.
4.2.2 MEASUREMENT INSTRUMENTS LIST
Below 1 GHz:
Item Kind of Equipment Manufacturer
1 Log-Bicon Antenna Schwarzbeck
Type No.
VULB 9160
Serial No.
3176
Calibrated until
Apr. 19, 2013
2
Pre-Amplifier
Anritsu
MH648A
M09961
Jun. 14, 2013
3
Test Cable
TIMES
LMR-400
30M
Jan. 15, 2014
LMR-400
OS01-1
Jan. 15, 2014
SCR 3501
408
Jan. 8, 2014
R3162
140100131
Sep. 7, 2013
4
5
6
7
8
9
Test Cable
TIMES
EMI Measuring
SHCAFFNER
Receiver
Spectrum Analyzer ADVANTEST
Positioning Controller
(OS01)
CT
SC100
N/A
N/A
Turn Table
Measurement
Software
Chance Most
CMTB-1.5
EZ_EMC
(Version NB-02A)
N/A
N/A
N/A
N/A
Type No.
BBHA 9120 D
Serial No.
9120D-325
Calibrated until
Jun. 18, 2013
8449B
3008A01714
Apr. 17, 2013
27478 LL142
1m
May. 14, 2013
S104-SMAP-1
10m
May. 14, 2013
27478 LL142
3m
May. 15, 2013
FSP-40
EZ_EMC
(Version NB-03A)
100129
Oct. 01, 2013
N/A
N/A
EZ
Above 1 GHz:
Item Kind of Equipment Manufacturer
1 Horn Antenna (1G) Schwarzbeck
Microwave
Agilent
2
Pre_amplifier
HARBOUR
Microflex Cable
3
INDUSTRIES
Microflex Cable
AISI
4
HARBOUR
Microflex Cable
5
INDUSTRIES
R&S
6 Spectrum Analyzer
Measurement
EZ
7
Software
Remark: “N/A” denotes No Model Name, No Serial No. or No Calibration specified.
Report No.: NEI-FCCE-1-1301030
Page 20 of 36
Neutron Engineering Inc.
RV-1302021
4.2.3 TEST PROCEDURE
a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3m or 10
meter open area test site. The table was rotated 360 degrees to determine the position of the
highest radiation.
b. The height of the equipment or of the substitution antenna shall be 0.8 m; the height of the test
antenna shall vary between 1 m to 4 m. Both horizontal and vertical polarizations of the
antenna are set to make the measurement.
c. The initial step in collecting radiated emission data is a spectrum analyzer peak detector mode
pre-scanning the measurement frequency range. Significant peaks are then marked and then
Quasi Peak detector mode re-measured.
d. If the Peak Mode measured value compliance with and lower than Quasi Peak Mode Limit, the
EUT shall be deemed to meet QP Limits and then no additional QP Mode measurement
performed.
e. For the actual test configuration, please refer to the related Item –EUT Test Photos.
NOTE: (Below 1 GHz)
a. Reading in which marked as QP or Peak means measurements by using are Quasi-Peak Mode
with Detector BW=120 kHz.
b. All readings are Peak unless otherwise stated QP in column of Note. Peak denotes that the Peak
reading compliance with the QP Limits and then QP Mode measurement didn‘t perform.
NOTE: (Above 1 GHz)
a. Reading in which marked as Peak means measurements by using are Peak Mode with
instrument setting in RBW= 1 MHz, VBW= 1 MHz.
Reading in which marked as AV means measurements by using are Average Mode with
instrument setting in RBW= 1 MHz, VBW= 10 Hz.
b. All readings are Peak Mode value unless otherwise stated AVG in column of Note. If the Peak
Mode Measured value compliance with the Peak Limits and lower than AVG Limits, the EUT shall
be deemed to meet both Peak & AVG Limits and then only Peak Mode was measured, but AVG
Mode didn‘t perform.
Report No.: NEI-FCCE-1-1301030
Page 21 of 36
Neutron Engineering Inc.
RV-1302021
4.2.4 DEVIATION FROM TEST STANDARD
No deviation
4.2.5 TEST SETUP
Below 1 GHz
Above 1 GHz
4.2.6 EUT OPERATING CONDITIONS
The EUT tested system was configured as the statements of 4.1.6 Unless otherwise a special
operating condition is specified in the follows during the testing.
Report No.: NEI-FCCE-1-1301030
Page 22 of 36
Neutron Engineering Inc.
RV-1302021
4.2.7 TEST RESULTS-BELOW 1 GHZ
E.U.T
Temperature
Test Voltage
Test Mode
IPC
Model Name
AMOS-800
29°C
Relative Humidity
77%
AC 120V/60Hz
FULL SYSTEM D-SUB 1680*1050/60Hz (ADAPTER: WA-15C05FU)
Polarization: Vertical
Report No.: NEI-FCCE-1-1301030
Page 23 of 36
Neutron Engineering Inc.
E.U.T
Temperature
Test Voltage
Test Mode
RV-1302021
IPC
Model Name
AMOS-800
29°C
Relative Humidity
77%
AC 120V/60Hz
FULL SYSTEM D-SUB 1680*1050/60Hz (ADAPTER: WA-15C05FU)
Polarization: Horizontal
Report No.: NEI-FCCE-1-1301030
Page 24 of 36
RV-1302021
Neutron Engineering Inc.
E.U.T
Temperature
Test Voltage
Test Mode
IPC
Model Name
AMOS-800
29°C
Relative Humidity
77%
AC 120V/60Hz
FULL SYSTEM D-SUB 1680*1050/60Hz (ADAPTER: FSP010-DWDA1)
Polarization: Vertical
Report No.: NEI-FCCE-1-1301030
Page 25 of 36
RV-1302021
Neutron Engineering Inc.
E.U.T
Temperature
Test Voltage
Test Mode
IPC
Model Name
AMOS-800
29°C
Relative Humidity
77%
AC 120V/60Hz
FULL SYSTEM D-SUB 1680*1050/60Hz (ADAPTER: FSP010-DWDA1)
Polarization: Horizontal
Report No.: NEI-FCCE-1-1301030
Page 26 of 36
Neutron Engineering Inc.
RV-1302021
4.2.8 TEST RESULTS-ABOVE 1 GHZ
E.U.T
Temperature
Test Voltage
Test Mode
IPC
Model Name
AMOS-800
26°C
Relative Humidity
60%
AC 120V/60Hz
FULL SYSTEM D-SUB 1680*1050/60Hz (ADAPTER: WA-15C05FU)
Polarization: Vertical
Report No.: NEI-FCCE-1-1301030
Page 27 of 36
Neutron Engineering Inc.
E.U.T
Temperature
Test Voltage
Test Mode
RV-1302021
IPC
Model Name
AMOS-800
26°C
Relative Humidity
60%
AC 120V/60Hz
FULL SYSTEM D-SUB 1680*1050/60Hz (ADAPTER: WA-15C05FU)
Polarization: Horizontal
Report No.: NEI-FCCE-1-1301030
Page 28 of 36
RV-1302021
Neutron Engineering Inc.
E.U.T
Temperature
Test Voltage
Test Mode
IPC
Model Name
AMOS-800
26°C
Relative Humidity
60%
AC 120V/60Hz
FULL SYSTEM D-SUB 1680*1050/60Hz (ADAPTER: FSP010-DWDA1)
Polarization: Vertical
Report No.: NEI-FCCE-1-1301030
Page 29 of 36
RV-1302021
Neutron Engineering Inc.
E.U.T
Temperature
Test Voltage
Test Mode
IPC
Model Name
AMOS-800
26°C
Relative Humidity
60%
AC 120V/60Hz
FULL SYSTEM D-SUB 1680*1050/60Hz (ADAPTER: FSP010-DWDA1)
Polarization: Horizontal
Report No.: NEI-FCCE-1-1301030
Page 30 of 36
RV-1302021
Neutron Engineering Inc.
5. EUT TEST PHOTO
Conducted emission test photos
FULL SYSTEM D-SUB 1680*1050/60Hz (ADAPTER: WA-15C05FU)
1301030
1301030
Report No.: NEI-FCCE-1-1301030
Page 31 of 36
RV-1302021
Neutron Engineering Inc.
Conducted emission test photos
FULL SYSTEM D-SUB 1680*1050/60Hz (ADAPTER: FSP010-DWDA1)
1301030
1301030
Report No.: NEI-FCCE-1-1301030
Page 32 of 36
RV-1302021
Neutron Engineering Inc.
Radiated emission test photos
Below 1 GHz
FULL SYSTEM D-SUB 1680*1050/60Hz (ADAPTER: WA-15C05FU)
1301030
1301030
Report No.: NEI-FCCE-1-1301030
Page 33 of 36
RV-1302021
Neutron Engineering Inc.
Radiated emission test photos
Below 1 GHz
FULL SYSTEM D-SUB 1680*1050/60Hz (ADAPTER: FSP010-DWDA1)
1301030
1301030
Report No.: NEI-FCCE-1-1301030
Page 34 of 36
RV-1302021
Neutron Engineering Inc.
Radiated emission test photos
Above 1 GHz
FULL SYSTEM D-SUB 1680*1050/60Hz (ADAPTER: WA-15C05FU)
1301030
1301030
Report No.: NEI-FCCE-1-1301030
Page 35 of 36
RV-1302021
Neutron Engineering Inc.
Radiated emission test photos
Above 1 GHz
FULL SYSTEM D-SUB 1680*1050/60Hz (ADAPTER: FSP010-DWDA1)
1301030
1301030
Report No.: NEI-FCCE-1-1301030
Page 36 of 36