MasterLogic-200 Analog Input Module (Isolated type)

Add to my manuals
2 Pages

advertisement

MasterLogic-200 Analog Input Module (Isolated type) | Manualzz

DATASHEET

MasterLogic-200

Analog Input Module (Isolated type)

2MLF-AD4S

10310000714 Printed in Korea

For more information on MasterLogic PLCs , contact your nearest Honeywell office

Australia

Honeywell Ltd.

Phone : (61) 2-9353-4500

Fax : (61) 2-9353-7677

China

Honeywell (Tianjin) Ltd. – Beijing

Phone: (86-10) 8458-3280

Fax: (86-10) 8458-3102

Honeywell (Tianjin) Ltd. – Shanghai

Phone: (86-21) 6237-0237

Fax : (86-21) 6237-3102

Indonesia

PT Honeywell Indonesia

Phone : (62) 21-535-8833

Fax : (62) 21-5367-1008

India

Honeywell Automation India Ltd.

Phone: (91) 20-5603-9400

Fax: (91) 20-5603-9800

Japan

Honeywell Inc.

Phone: (81)3-5440-1395

Fax: (81)3-5440-1368

South Korea

Honeywell Co., Ltd.

Phone : (82) 2-799-6114

Fax : (82) 2-792-9015

Malaysia

Honeywell Engineering Sdn Bhd.

Phone: (603) 7958-4988

Fax: (603) 7958-8922

New Zealand

Honeywell Ltd.

Phone: (64-9) 623-5050

Fax: (64-9) 623-5060

Philippines

Honeywell Systems Inc.

Phone: (63-2) 633-2830

Fax: (63-2) 638-4013

Singapore

Honeywell Pte Ltd.

Phone: (65) 6355-2828

Fax: (65) 6445-3033

Thailand

Honeywell Systems Ltd.

Phone: (662) 693-3099

Fax: (662) 693-3085

Taiwan

Honeywell Taiwan Ltd.

Phone: (886) 2-2245-1000

Fax: (886) 2-2245-3241

For Countries (SE Asia) Listed below, call Honeywell Singapore

Office

Pakistan, Cambodia, Laos,

Myanmar, Vietnam and East Timor

For Countries Listed below, call Honeywell India Office

Bangladesh, Nepal, and Sri Lanka

Honeywell Co., Ltd.

Honeywell Process Solutions

17F, Kukje Center Building, 191 Hangangro-2ga,

Yongsan-gu, Seoul 140-702, Korea

Tel : 82-2-799-6114 / Fax : 82-2-792-9015

Email: MasterLogic_support @Honeywell.com

10310000714 Printed in Korea

o Safety Precautions

► Safety Precautions is for using the product safe and correct in order to prevent the accidents and danger, so please go by them.

► The precautions explained here only apply to the 2MLF-AD4S unit. For safety precautions on the

PLC system, refer to the MasterLogic-200 CPU manual.

► The precautions are divided into 2 sections, ‘Warning’ and ‘Caution’. Each of the meanings is represented as follows.

Warning

Caution

If violated instructions, it can cause death, fatal injury or considerable loss of property.

If violated instructions, it can cause a slight injury or slight loss of products

► The symbols which are indicated in the PLC and User’s Manual mean as follows

Gives warnings and cautions to prevent from risk of injury, fire, or malfunction

Gives warnings and cautions to prevent from risk of electrical shock.

► Store this datasheet in a safe place so that you can take out and read whenever necessary. Always forward it to the end user.

Warning

► Do not contact the terminals while the power is applied.

Risk of electric shock and malfunction

► Protect the product from being gone into by foreign metallic matter.

Risk of fire, electric shock and malfunction.

Caution

► Be sure to check the rated voltage and terminal arrangement for the module before wiring work.

Risk of electric shock, fire and malfunction

► Tighten the screw of terminal block with the specified torque range.

If the terminal screw looses, it can cause fire and electric shock.

► Use the PLC in an environment that meets the general specifications contained in this datasheet.

Risk of electrical shock, fire, erroneous operation and deterioration of the PLC.

► Be sure that external load does not exceed the rating of output module.

Risk of fire and erroneous operation.

► Do not use the PLC in the environment of direct vibration

Risk of electrical shock, fire and erroneous operation.

► Do not disassemble, repair or modify the PLC.

Risk of electrical shock, fire and erroneous operation.

► When disposing of PLC and battery, treat it as industrial waste.

Risk of poisonous pollution or explosion.

Precautions for use

► Do not Install other places except PLC controlled place.

► Make sure that the FG terminal is grounded with class 3 grounding which is dedicated to the

PLC. Otherwise, it can cause disorder or malfunction of PLC

PLC Others PLC Others PLC Others

< Best > < Good > < Bad >

► Connect expansion connector correctly when expansion module are needed,

► Do not detach PCB from the case of the module and do not modify the module.

► Turn off power when attaching or detaching module.

► Cellular phone or walkie-talkie should be farther than 30cm from the PLC

► Input signal and communication line should be farther than minimum 100mm from a high-tension line and a power line in order not to be affected by noise and magnetic field.

Before handling the product

Before using the product, read the datasheet and the User’s manual through to the end carefully in order to use the product efficiently.

MasterLogic-200 Series User’s Manual

Name

MasterLogic-200 User’s manual(Programming software)

MasterLogic-200 Basic Instruction & Programming User’s manual

Code

10310000512

10310000510

1. Introduction

A/D conversion module designed for MasterLogic-200 series is used to convert analog signal (voltage or current input) to the digital value of signed 16-bit binary data specified in

PLC CPU.

2. General Specifications

General specifications of MasterLogic-200 series are as specified in Table

No Item Specifications Standard

1 Operating temp.

2 Storage temp.

3

Operating humidity

4 Storage humidity

0℃∼+ 55℃

-25℃∼+70℃

5∼95%RH (Non-condensing)

5 Vibration

5∼95%RH (Non-condensing)

For discontinuous vibration

Frequency Acceleration Amplitude Number

10≤f< 57㎐ - 0.075mm

57≤f≤150㎐ 9.8m/s2(1G)

For continuous vibration

Frequency Acceleration

-

Amplitude

Each 10 times in

X,Y,Z

6 Shocks

10≤f< 57㎐

57≤f≤150㎐ 4.9m/s2(0.5G) -

* Max. impact acceleration:147㎨(15G)

* Authorized time :11㎳

* Pulse wave : Sign half-wave pulse (Each 3 times in X,Y,Z

directions)

7 Noise

8

Ambient conditions

9 Operating height

10 Pollution degree

11 Cooling method

Square wave impulse noise

Electrostatic discharging

Radiated electromagnetic field noise

Fast

Transient

/burst noise

Class

Voltage

Power module

Voltage : 4kV(contact discharging)

27 ~ 500MHz, 10 V/m

Digital/Analog I/O communication interface

2kV 1

No corrosive gas or dust

2000m or less

2 or less

Self-cooling

IEC61131-2

IEC61131-2

IEC61131-2

IEC61000-4-2

IEC61131-2,

IEC61000-4-3

IEC61131-2

IEC61000-4-4

3. Performance Specifications

Performance specifications of A/D conversion module are as specified in Table

Specifications

Item

Analog input

Analog input range setting

Digital output

The max. resolution

Accuracy

Max. conversion speed

Absolute max. input

Analog input points

Voltage input Current input

DC 1 5 V

DC 0 5 V

(Input Resistance: 1 MΩ min.)

DC 4 ∼ 20 mA

DC 0 ~ 20 mA

(Input Resistance 250 Ω)

► Analog input range can be selected through user program or Software package.

(When using the current input the terminal V+ and I+ should be shorted)

► Respective input ranges can be set based on channels.

(1) Voltage Type

Analog input

1 ~ 5 V 0 ~ 5 V 0 ~ 10 V -10 ~ 10 V

Digital output

Signed Value -32000 ~ 32000

Precise Value

1000 ~

5000

0 ~ 5000 0 ~ 10000

-10000 ~

10000

Percentile Value

(2) Current Type

0 ~ 10000

Analog input

4 ~ 20 mA 0 ~ 20 mA

Digital output

Signed Value

Precise Value

Percentile Value

4000 ~ 20000

-32000 ~ 32000

0 ~ 20000

0 ~ 10000

► 16-bit binary value

► Format of digital output data can be set through user program or S/W package respectively based on channels.

Analog input range Resolution (1/64000) Analog input range Resolution (1/64000)

1 ~ 5 V

0 ~ 5 V

62.5 ㎶

78.1 ㎶

4 ~ 20 mA 250 ㎁

0 ~ 10 V

-10 ~ 10 V

156.3 ㎶

0 ~ 20 mA

312.5 ㎶

±0.05% (when ambient temperature is 25 ℃ ±5℃)

Temperature coefficient: ±40ppm/℃ (0.0040 %/℃)

312.5 ㎁

±15 V

10㎳/ channel

4 channels

±30 mA

Between channels Isolation (Trans)

Insulation method

Between terminal –

PLC power supply

Isolation (Photo-Coupler)

Terminal connected

I/O points occupied

Internalconsumed current

Weight

18-point terminal

Fixed point assignment: 64 , Variable point assignment : 16

DC 5 V: 610㎃

140g

Notes

▶ When A/D conversion module is released from the factory, Offset/Gain value is as adjusted for

respective analog input ranges, which is unavailable for user to change.

4. Part names of functions

Part names of functions are as described below

No Name Descriptions

① RUN LED

▶ Displays the operation status

On: Operation normal

Blinks(0.2s): Error occurs (Refer to 2MLF-AD4S user’s manual)

Off: DC 5V disconnected, module error

▶ Displays the alarm status

② ALM Blinks: Alarm (Processing alarm, Change rate alarm) detected

Off: Operation normal

③ Terminal

▶ Analog input terminal, whose respective channels can be connected with external devices.

5. Handling precaution

1) Do not drop or impact the product.

2) Do not detach PCB from the case, it may cause malfunction.

3) During wiring or other work, do not allow any wire chips get inside the product.

4) Switch the external power off before mounting or removing the module and the cable.

6. Wiring

6.1 Precautions for wiring

1) Don’t let AC power line near to analog input module’s external input signal line. With an enough distance kept away between, it will be free from surge or inductive noise.

2) Cable shall be selected in due consideration of ambient temperature and allowable current, whose size is not less than the max. cable standard of

AWG22 (0.3㎟).

3) Don’t let the cable too close to hot device and material or in direct contact with oil for long, which will cause damage or abnormal operation due to short-circuit.

4) Check the polarity when wiring the terminal.

5) Wiring with high-voltage line or power line may produce inductive hindrance causing abnormal operation or defect.

6.2 Wiring Example

+

-

+

-

1) Voltage input

*1

*1

2) Current input

CH0

CH3

V0+

I0+

COM0

V3+

I3+

COM3

R

R

*2

R

R

R

R

*3

Address

UXY.09.0

UXY.09.1

UXY.09.2

UXY.09.3

UXY.09.4

UXY.09.5

UXY.09.6

UXY.09.7

UXY.10.0

UXY.10.1

UXY.10.2

UXY.10.3

UXY.11.0

UXY.08.0

UXY.08.1

UXY.08.2

UXY.08.3

UXY.08.4

UXY.08.5

UXY.08.6

UXY.08.7

UXY.08.8

UXY.08.9

UXY.08.A

UXY.08.B

UXY.08.C

UXY.08.D

UXY.08.E

UXY.08.F

Description

Ch0 high-high processing alarm (HH)

Ch0 high processing alarm (H)

Ch0 low processing alarm (L)

Ch0 low-low processing alarm (LL)

Ch1 high-high processing alarm (HH)

Ch1 high processing alarm (H)

Ch1 low processing alarm (L)

Ch1 low-low processing alarm (LL)

Ch2 high-high processing alarm (HH)

Ch2 high processing alarm (H)

Ch2 low processing alarm (L)

Ch2 low-low processing alarm (LL)

Ch3 high-high processing alarm (HH)

Ch3 high processing alarm (H)

Ch3 low processing alarm (L)

Ch3 low-low processing alarm (LL)

Ch0 high alarm of change rate (H)

Ch0 low alarm of change rate (L)

Ch1 high alarm of change rate (H)

Ch1 low alarm of change rate (L)

Ch2 high alarm of change rate (H)

Ch2 low alarm of change rate (L)

Ch3 high alarm of change rate (H)

Ch3 low alarm of change rate (L)

Flag to detect CH0 disconnection (1 ~ 5 V or 4 ~ 20 mA)

Flag to detect CH1 disconnection (1 ~ 5 V or 4 ~ 20 mA)

Flag to detect CH2 disconnection (1 ~ 5 V or 4 ~ 20 mA)

Flag to detect CH3 disconnection (1 ~ 5 V or 4 ~ 20 mA)

Flag to request error clear

+

+

-

-

*1

*1

*4

*4

CH0

CH3

V0+

I0+

COM0

V3+

I3+

COM3

R

R

*2

R

R

R

R

*3

*1) Use the cable of 2-core twisted shield. AWG 22 is recommended for the cable standard.

*2) The Input resistance voltage input is 250 Ω (typ.).

*3) The Input resistance current input is 1 MΩ (min.).

*4) When using the current input, short the V+ terminal and I+ terminal.

7. Configuration of internal memory

7.1 I/O area of A/D converted data

Address Description

UXY.00.0

UXY.00.F

UXY.01.0

UXY.01.1

UXY.01.2

UXY.01.3

UXY.02

UXY.03

UXY.04

H/W error

Module ready

Ch0 run flag

Ch1 run flag

Ch2 run flag

Ch3 run flag

CH0 digital output value

CH1 digital output value

CH2 digital output value

UXY.05 CH03digital output value

UXY.06 Reserved

UXY.07 Reserved

7.2 A/D Setting area of Run parameters

R/W

R

R

R

R

R

R

R

R

Dec

Description

0

H

1

H

2

H

12

H

13

H

14

H

15

H

16

H

17

H

18

H

A

H

B

H

C

H

D

H

E

H

F

H

10

H

11

H

1

2

Input range selection

Digital output type selection

3

H

3 Filter process enable/disable

4

H

4 CH0 filter constant

5

H

6

H

5

6

CH1 filter constant

CH2 filter constant

7

H

8

H

7

8

CH3 filter constant

Alarm enable/disable (Processing/Change rate)

9

H

9 Ch0 high-high value of processing alarm (HH)

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

Ch0 high value of processing alarm (H)

Ch0 low value of processing alarm (L)

Ch0 low-low value of processing alarm (LL)

Ch1 high-high value of processing alarm (HH)

Ch1 high value of processing alarm (H)

Ch1 low value of processing alarm (L)

Ch1 low-low value of processing alarm (LL)

Ch2 high-high value of processing alarm (HH)

Ch2 high value of processing alarm (H)

Ch2 low value of processing alarm (L)

Ch2 low-low value of processing alarm (LL)

Ch3 high-high value of processing alarm (HH)

Ch3 high value of processing alarm (H)

Ch3 low value of processing alarm (L)

Ch3 low-low value of processing alarm (LL)

19

1A

Address

H

H

1B

H

1C

H

1D

H

1E

H

1F

H

20

H

21

H

22

H

23

H

24

H

25

H

Hex

25

26

27

28

29

30

31

32

33

34

35

36

Period of ch0 change rate

Period of ch1 change rate

Period of ch2 change rate

Period of ch3 change rate

High limit of ch0 change rate

Low limit of ch0 change rate

High limit of ch1 change rate

Low limit of ch1 change rate

High limit of ch2 change rate

Low limit of ch2 change rate

High limit of ch3 change rate

Low limit of ch3 change rate

R/W

R/W PUT

R/W

R/W

PUT

PUT

R/W PUT

R/W

R/W

R

W

Remark

R/W PUT

PUT

R/W PUT

R/W PUT

R/W PUT

R/W PUT

R/W PUT

R/W PUT

8. Dimensions

Unit : ㎜