DATASHEET
MasterLogic-200
Analog Input Module (Isolated type)
2MLF-AD4S
10310000714 Printed in Korea
For more information on MasterLogic PLCs , contact your nearest Honeywell office
Australia
Honeywell Ltd.
Phone : (61) 2-9353-4500
Fax : (61) 2-9353-7677
China
Honeywell (Tianjin) Ltd. – Beijing
Phone: (86-10) 8458-3280
Fax: (86-10) 8458-3102
Honeywell (Tianjin) Ltd. – Shanghai
Phone: (86-21) 6237-0237
Fax : (86-21) 6237-3102
Indonesia
PT Honeywell Indonesia
Phone : (62) 21-535-8833
Fax : (62) 21-5367-1008
India
Honeywell Automation India Ltd.
Phone: (91) 20-5603-9400
Fax: (91) 20-5603-9800
Japan
Honeywell Inc.
Phone: (81)3-5440-1395
Fax: (81)3-5440-1368
South Korea
Honeywell Co., Ltd.
Phone : (82) 2-799-6114
Fax : (82) 2-792-9015
Malaysia
Honeywell Engineering Sdn Bhd.
Phone: (603) 7958-4988
Fax: (603) 7958-8922
New Zealand
Honeywell Ltd.
Phone: (64-9) 623-5050
Fax: (64-9) 623-5060
Philippines
Honeywell Systems Inc.
Phone: (63-2) 633-2830
Fax: (63-2) 638-4013
Singapore
Honeywell Pte Ltd.
Phone: (65) 6355-2828
Fax: (65) 6445-3033
Thailand
Honeywell Systems Ltd.
Phone: (662) 693-3099
Fax: (662) 693-3085
Taiwan
Honeywell Taiwan Ltd.
Phone: (886) 2-2245-1000
Fax: (886) 2-2245-3241
For Countries (SE Asia) Listed below, call Honeywell Singapore
Office
Pakistan, Cambodia, Laos,
Myanmar, Vietnam and East Timor
For Countries Listed below, call Honeywell India Office
Bangladesh, Nepal, and Sri Lanka
Honeywell Co., Ltd.
Honeywell Process Solutions
17F, Kukje Center Building, 191 Hangangro-2ga,
Yongsan-gu, Seoul 140-702, Korea
Tel : 82-2-799-6114 / Fax : 82-2-792-9015
Email: MasterLogic_support @Honeywell.com
10310000714 Printed in Korea
o Safety Precautions
► Safety Precautions is for using the product safe and correct in order to prevent the accidents and danger, so please go by them.
► The precautions explained here only apply to the 2MLF-AD4S unit. For safety precautions on the
PLC system, refer to the MasterLogic-200 CPU manual.
► The precautions are divided into 2 sections, ‘Warning’ and ‘Caution’. Each of the meanings is represented as follows.
Warning
Caution
If violated instructions, it can cause death, fatal injury or considerable loss of property.
If violated instructions, it can cause a slight injury or slight loss of products
► The symbols which are indicated in the PLC and User’s Manual mean as follows
Gives warnings and cautions to prevent from risk of injury, fire, or malfunction
Gives warnings and cautions to prevent from risk of electrical shock.
► Store this datasheet in a safe place so that you can take out and read whenever necessary. Always forward it to the end user.
Warning
► Do not contact the terminals while the power is applied.
Risk of electric shock and malfunction
► Protect the product from being gone into by foreign metallic matter.
Risk of fire, electric shock and malfunction.
Caution
► Be sure to check the rated voltage and terminal arrangement for the module before wiring work.
Risk of electric shock, fire and malfunction
► Tighten the screw of terminal block with the specified torque range.
If the terminal screw looses, it can cause fire and electric shock.
► Use the PLC in an environment that meets the general specifications contained in this datasheet.
Risk of electrical shock, fire, erroneous operation and deterioration of the PLC.
► Be sure that external load does not exceed the rating of output module.
Risk of fire and erroneous operation.
► Do not use the PLC in the environment of direct vibration
Risk of electrical shock, fire and erroneous operation.
► Do not disassemble, repair or modify the PLC.
Risk of electrical shock, fire and erroneous operation.
► When disposing of PLC and battery, treat it as industrial waste.
Risk of poisonous pollution or explosion.
Precautions for use
► Do not Install other places except PLC controlled place.
► Make sure that the FG terminal is grounded with class 3 grounding which is dedicated to the
PLC. Otherwise, it can cause disorder or malfunction of PLC
PLC Others PLC Others PLC Others
< Best > < Good > < Bad >
► Connect expansion connector correctly when expansion module are needed,
► Do not detach PCB from the case of the module and do not modify the module.
► Turn off power when attaching or detaching module.
► Cellular phone or walkie-talkie should be farther than 30cm from the PLC
► Input signal and communication line should be farther than minimum 100mm from a high-tension line and a power line in order not to be affected by noise and magnetic field.
Before handling the product
Before using the product, read the datasheet and the User’s manual through to the end carefully in order to use the product efficiently.
MasterLogic-200 Series User’s Manual
Name
MasterLogic-200 User’s manual(Programming software)
MasterLogic-200 Basic Instruction & Programming User’s manual
Code
10310000512
10310000510
1. Introduction
A/D conversion module designed for MasterLogic-200 series is used to convert analog signal (voltage or current input) to the digital value of signed 16-bit binary data specified in
PLC CPU.
2. General Specifications
General specifications of MasterLogic-200 series are as specified in Table
No Item Specifications Standard
1 Operating temp.
2 Storage temp.
3
Operating humidity
4 Storage humidity
0℃∼+ 55℃
-25℃∼+70℃
5∼95%RH (Non-condensing)
5 Vibration
5∼95%RH (Non-condensing)
For discontinuous vibration
Frequency Acceleration Amplitude Number
10≤f< 57㎐ - 0.075mm
57≤f≤150㎐ 9.8m/s2(1G)
For continuous vibration
Frequency Acceleration
-
Amplitude
Each 10 times in
X,Y,Z
6 Shocks
10≤f< 57㎐
57≤f≤150㎐ 4.9m/s2(0.5G) -
* Max. impact acceleration:147㎨(15G)
* Authorized time :11㎳
* Pulse wave : Sign half-wave pulse (Each 3 times in X,Y,Z
directions)
7 Noise
8
Ambient conditions
9 Operating height
10 Pollution degree
11 Cooling method
Square wave impulse noise
Electrostatic discharging
Radiated electromagnetic field noise
Fast
Transient
/burst noise
Class
Voltage
Power module
Voltage : 4kV(contact discharging)
27 ~ 500MHz, 10 V/m
Digital/Analog I/O communication interface
2kV 1
No corrosive gas or dust
2000m or less
2 or less
Self-cooling
IEC61131-2
IEC61131-2
IEC61131-2
IEC61000-4-2
IEC61131-2,
IEC61000-4-3
IEC61131-2
IEC61000-4-4
3. Performance Specifications
Performance specifications of A/D conversion module are as specified in Table
Specifications
Item
Analog input
Analog input range setting
Digital output
The max. resolution
Accuracy
Max. conversion speed
Absolute max. input
Analog input points
Voltage input Current input
DC 1 5 V
DC 0 5 V
(Input Resistance: 1 MΩ min.)
DC 4 ∼ 20 mA
DC 0 ~ 20 mA
(Input Resistance 250 Ω)
► Analog input range can be selected through user program or Software package.
(When using the current input the terminal V+ and I+ should be shorted)
► Respective input ranges can be set based on channels.
(1) Voltage Type
Analog input
1 ~ 5 V 0 ~ 5 V 0 ~ 10 V -10 ~ 10 V
Digital output
Signed Value -32000 ~ 32000
Precise Value
1000 ~
5000
0 ~ 5000 0 ~ 10000
-10000 ~
10000
Percentile Value
(2) Current Type
0 ~ 10000
Analog input
4 ~ 20 mA 0 ~ 20 mA
Digital output
Signed Value
Precise Value
Percentile Value
4000 ~ 20000
-32000 ~ 32000
0 ~ 20000
0 ~ 10000
► 16-bit binary value
► Format of digital output data can be set through user program or S/W package respectively based on channels.
Analog input range Resolution (1/64000) Analog input range Resolution (1/64000)
1 ~ 5 V
0 ~ 5 V
62.5 ㎶
78.1 ㎶
4 ~ 20 mA 250 ㎁
0 ~ 10 V
-10 ~ 10 V
156.3 ㎶
0 ~ 20 mA
312.5 ㎶
±0.05% (when ambient temperature is 25 ℃ ±5℃)
Temperature coefficient: ±40ppm/℃ (0.0040 %/℃)
312.5 ㎁
±15 V
10㎳/ channel
4 channels
±30 mA
Between channels Isolation (Trans)
Insulation method
Between terminal –
PLC power supply
Isolation (Photo-Coupler)
Terminal connected
I/O points occupied
Internalconsumed current
Weight
18-point terminal
Fixed point assignment: 64 , Variable point assignment : 16
DC 5 V: 610㎃
140g
Notes
▶ When A/D conversion module is released from the factory, Offset/Gain value is as adjusted for
respective analog input ranges, which is unavailable for user to change.
4. Part names of functions
Part names of functions are as described below
③
①
②
No Name Descriptions
① RUN LED
▶ Displays the operation status
On: Operation normal
Blinks(0.2s): Error occurs (Refer to 2MLF-AD4S user’s manual)
Off: DC 5V disconnected, module error
▶ Displays the alarm status
② ALM Blinks: Alarm (Processing alarm, Change rate alarm) detected
Off: Operation normal
③ Terminal
▶ Analog input terminal, whose respective channels can be connected with external devices.
5. Handling precaution
1) Do not drop or impact the product.
2) Do not detach PCB from the case, it may cause malfunction.
3) During wiring or other work, do not allow any wire chips get inside the product.
4) Switch the external power off before mounting or removing the module and the cable.
6. Wiring
6.1 Precautions for wiring
1) Don’t let AC power line near to analog input module’s external input signal line. With an enough distance kept away between, it will be free from surge or inductive noise.
2) Cable shall be selected in due consideration of ambient temperature and allowable current, whose size is not less than the max. cable standard of
AWG22 (0.3㎟).
3) Don’t let the cable too close to hot device and material or in direct contact with oil for long, which will cause damage or abnormal operation due to short-circuit.
4) Check the polarity when wiring the terminal.
5) Wiring with high-voltage line or power line may produce inductive hindrance causing abnormal operation or defect.
6.2 Wiring Example
+
-
+
-
1) Voltage input
*1
*1
2) Current input
CH0
CH3
V0+
I0+
COM0
V3+
I3+
COM3
R
R
*2
R
R
R
R
*3
Address
UXY.09.0
UXY.09.1
UXY.09.2
UXY.09.3
UXY.09.4
UXY.09.5
UXY.09.6
UXY.09.7
UXY.10.0
UXY.10.1
UXY.10.2
UXY.10.3
UXY.11.0
UXY.08.0
UXY.08.1
UXY.08.2
UXY.08.3
UXY.08.4
UXY.08.5
UXY.08.6
UXY.08.7
UXY.08.8
UXY.08.9
UXY.08.A
UXY.08.B
UXY.08.C
UXY.08.D
UXY.08.E
UXY.08.F
Description
Ch0 high-high processing alarm (HH)
Ch0 high processing alarm (H)
Ch0 low processing alarm (L)
Ch0 low-low processing alarm (LL)
Ch1 high-high processing alarm (HH)
Ch1 high processing alarm (H)
Ch1 low processing alarm (L)
Ch1 low-low processing alarm (LL)
Ch2 high-high processing alarm (HH)
Ch2 high processing alarm (H)
Ch2 low processing alarm (L)
Ch2 low-low processing alarm (LL)
Ch3 high-high processing alarm (HH)
Ch3 high processing alarm (H)
Ch3 low processing alarm (L)
Ch3 low-low processing alarm (LL)
Ch0 high alarm of change rate (H)
Ch0 low alarm of change rate (L)
Ch1 high alarm of change rate (H)
Ch1 low alarm of change rate (L)
Ch2 high alarm of change rate (H)
Ch2 low alarm of change rate (L)
Ch3 high alarm of change rate (H)
Ch3 low alarm of change rate (L)
Flag to detect CH0 disconnection (1 ~ 5 V or 4 ~ 20 mA)
Flag to detect CH1 disconnection (1 ~ 5 V or 4 ~ 20 mA)
Flag to detect CH2 disconnection (1 ~ 5 V or 4 ~ 20 mA)
Flag to detect CH3 disconnection (1 ~ 5 V or 4 ~ 20 mA)
Flag to request error clear
+
+
-
-
*1
*1
*4
*4
CH0
CH3
V0+
I0+
COM0
V3+
I3+
COM3
R
R
*2
R
R
R
R
*3
*1) Use the cable of 2-core twisted shield. AWG 22 is recommended for the cable standard.
*2) The Input resistance voltage input is 250 Ω (typ.).
*3) The Input resistance current input is 1 MΩ (min.).
*4) When using the current input, short the V+ terminal and I+ terminal.
7. Configuration of internal memory
7.1 I/O area of A/D converted data
Address Description
UXY.00.0
UXY.00.F
UXY.01.0
UXY.01.1
UXY.01.2
UXY.01.3
UXY.02
UXY.03
UXY.04
H/W error
Module ready
Ch0 run flag
Ch1 run flag
Ch2 run flag
Ch3 run flag
CH0 digital output value
CH1 digital output value
CH2 digital output value
UXY.05 CH03digital output value
UXY.06 Reserved
UXY.07 Reserved
7.2 A/D Setting area of Run parameters
R/W
R
R
R
R
R
R
R
R
Dec
Description
0
H
1
H
2
H
12
H
13
H
14
H
15
H
16
H
17
H
18
H
A
H
B
H
C
H
D
H
E
H
F
H
10
H
11
H
1
2
Input range selection
Digital output type selection
3
H
3 Filter process enable/disable
4
H
4 CH0 filter constant
5
H
6
H
5
6
CH1 filter constant
CH2 filter constant
7
H
8
H
7
8
CH3 filter constant
Alarm enable/disable (Processing/Change rate)
9
H
9 Ch0 high-high value of processing alarm (HH)
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
Ch0 high value of processing alarm (H)
Ch0 low value of processing alarm (L)
Ch0 low-low value of processing alarm (LL)
Ch1 high-high value of processing alarm (HH)
Ch1 high value of processing alarm (H)
Ch1 low value of processing alarm (L)
Ch1 low-low value of processing alarm (LL)
Ch2 high-high value of processing alarm (HH)
Ch2 high value of processing alarm (H)
Ch2 low value of processing alarm (L)
Ch2 low-low value of processing alarm (LL)
Ch3 high-high value of processing alarm (HH)
Ch3 high value of processing alarm (H)
Ch3 low value of processing alarm (L)
Ch3 low-low value of processing alarm (LL)
19
1A
Address
H
H
1B
H
1C
H
1D
H
1E
H
1F
H
20
H
21
H
22
H
23
H
24
H
25
H
Hex
25
26
27
28
29
30
31
32
33
34
35
36
Period of ch0 change rate
Period of ch1 change rate
Period of ch2 change rate
Period of ch3 change rate
High limit of ch0 change rate
Low limit of ch0 change rate
High limit of ch1 change rate
Low limit of ch1 change rate
High limit of ch2 change rate
Low limit of ch2 change rate
High limit of ch3 change rate
Low limit of ch3 change rate
R/W
R/W PUT
R/W
R/W
PUT
PUT
R/W PUT
R/W
R/W
R
W
Remark
R/W PUT
PUT
R/W PUT
R/W PUT
R/W PUT
R/W PUT
R/W PUT
R/W PUT
8. Dimensions
Unit : ㎜