OKINA
OK-PTZ-KB250X
3-Axis Compact
Keyboard Controller
Before Starting
- Refer all work related to the installaion of this product to qualified
service personnel or system installers.
To prevent electric shock,
- Do not attemp to disassemble the keyboard
do not remove screws or cover. There are no user-serviceable parts
inside. Contact qualified service personnel for maintenance
Do not strike or shake, as this may
- Handle the keyboard with care.
damage the keyboard. It should be protected against extreme pressure,
vibration and humidity during transportation, storage and operation.
Damages caused by improper transportation avoid the warranty.
- Do not operate the apliance beyond its specified temperature,
humidity or power source ratings.
Do not use the keyboard in an
extreme environment where high temperature or high humidity exists.
Use it within -5°C to +40°C(23°F to 140°F) and a humidity below 90%.
The input power source is 12V DC, and requires at least 500mA.
- Read this user's manual carefully before operation.
Make sure that
local electric safty standards are followed when using or installing the
keyboard.
RS-485 (A+/ B-)
For connection to PTZ, Speed-Domes or other device which support
telemetric controling with RS-485 interface. The max. Distance can be up to
1000 meter ( depends on cable and environmental condition).
RS-422 (T+/T-/R+/R-)
Rs422 Inteface for telemetric control, up to 1200 meters.
RJ-45
Control interface forr matrix device(e.g. Pelco Cm6700,CM6800).
DC Power Input
Power supply for the keyboard, Voltage range is 9V to 12V in DC or AC
without polarity( auto-sensing). When connecedt to the Matrix, the keyboard
can be powered thourgh the RJ-45 Interface.
Check list
- Do not install this Product in a flammable and explosive
environment.
- Do not install or operate the keyboard near any high-voltage devices
or high-voltage cable. The safety distance should remain at least 50 m.
- This product should be operated indoor only.
User's Manual
Unpacking
Warning
A(+)
B(+)
R S -4 8 5
TX(+)
TX(-)
RX(+)
RX(-)
R S -4 2 2
TX(+)
TX(-)
RX(+)
RX(-)
Baud-Rate: The keyboard and the camera devices must have the same
baud-rate setting, in order to establish the data exchange. Available settings
are 2400, 4800 and 9600 Bps. For settings on the camera device, please
refer to camera’s manual for further details.
Protocol: Make sure that the keyboard and camera devices are set with the
same protocol. Currently Pelco and B01/B02 are supported by the
keyboard.please refer to camera’s manual for details.
Technical specifications are subjects to change without prior notice. This
Manual may contain printing or clerical errors. All trademarks mentioned
belong to their respective owners.
CAUTION: TO REDUCE THE
RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER (
OR BACK). NO USER
SERVICEABLE PARTS
INSIDE. REFER SERVICING
TO QUALIFIED SERVICE
PERSONNEL
This symbol indicates that there
are important operating and
maintenance instructions in the
literature accompanying this unit.
Recall / activate Tour
To start the tour, press
[n] + [TOUR]
N.. Number of the stored tour
Setup 2-Points scan
Scan between 2 pre-defined points. To define the points, move to
the left end and press [SET]+[1] + [SCAN], and move to the right
end and press [SET] +[2]+ [SCAN] to store the position.
For changing the scan speed, you need to enter the PTZ’s OSD
menu. Please refer to the users manual for details.
[SET] + [n] + [PATTERN]. n....the number of pattern track.
LCD
Display
Function Keys
1x User Manual
To stop the pattern recording, press
[SET] + [0] + [PATTERN]
Activate recorded Pattern
To activate the recorded pattern, press
[N] + [PATTERN]
Digit Keys
Connection
Camera
Function keys
I nitial Screen
FCC COMPLIANCE STATEMENT
Cam ID:001
Mon ID:001
P r o t o c o l : B01
Baudrate: 9600bps
Cam ID: Current camera ID
Mon ID: Current monitor ID, indicates the ouput setting on matrix.
Protocol: Telemetric protocol setting.
Baudrate: Baud-Rate setting
FCC INFORMATION: THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE
LIMITS FOR A CLASS A DIGITAL DEVICE, PURSUANT TO PART 15 OF THE FCC RULES. THESE
LIMITS ARE DESIGHEND TO PROVIDE REASONABLE PROTECTION AGAINST HAMRFUL
INTERFERENCE WHEN THE EQUIPMENT IS OPERATED IN A COMMERCIAL ENVIRONMENT. THIS
EQUIPMENT GENERATES, USES, AND CAN RADIATE RADIO FREQUENCY ENGERGY AND IF NOT
INSTALLED AND USED IN ACCORDANCE WITH THE INSTRUCTION MANUAL, MAY CAUSE HARMFUL
INTERFERENCE TO RADIO COMMUNICATIONS. OPERATION OF THIS EQUIPMENT IN A
RESIDENTIAL AREA IS LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH CASE THE USER
WILL BE REQUIRED TO CORRECT THE INTERFERENCE AT HIS OWN EXPENSE.
RS-422
Interface
CAUTION: CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY
RESPONSIBLE FOR COMPLIANCE COULD VOID THE USERS‘S AUTHORITY TO OPERATE THE
EQUIPMENT.
CE COMPLIANCE STATEMENT
Matrix
Interface
Power
Input
Matrix
WARNING: THIS IS A CLASS A PRODUCT. IN A DOMESTIC ENVIRONMENT THIS PRODUCT MAY
CAUSE RADIO INTERFERENCE IN WHICH CASE THE USER MAY BE REQUIRED TO TAKE ADEQUATE
MEASURES.
This Symbol indicates that this product should not be treated as household
waste. When discarding this product, it must be sent to appropriate facilities for
recycling or recovery. By separating this product from other household waste,
you are helping to reduce the volume of waste incinerators and the natural
resource will be conserved.
You need to enter the keyboard’s menu to setup the tour. Pleare
refer to the later chapter for setup.
Start / Stop Pattern recording
The pattern function records user’s PTZ movement, and can be
recalled when need. Depends on the camera device, the
recording time and supported number of pattern tracks might
differ. To start the recording procedure, press
USER'S MANUAL
1 X Controller
Set Tour function (B01)
For settings of your keyboard. Please refer to later chapters for details
Programmable
Keyboard Controller
AC-DC Power
Supply (optional)
Move the PTZ to the desired position and press
[SET]+ [n] + [PRESET]
To store the current position as a preset n
Start 2-Points Scan
Press [1]+[SCAN] to start the scan procedure.
3 Axis Joystick
This symbol indicates that
dangerous voltage constituting a
risk of electric shock is present
within this unit.
Press [n] + [CAM] : n.. ID of the camera
Set / define a Preset position
Camera ID : Make sure that every connected PTZ device is assigned with
an unique ID.
Operation
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS
PRODUCT TO RAIN OR MOISTURE. DO NOT INSERT ANY METALLIC OBJECTS
THROUGH THE VENTILATION GRILLS OR OTHER OPENINGS ON THE EQUIPMENT.
Change currently selected camera
To recall the memorized preset position, press
[n] + [PRESET]
N.... The number of preset to be recalled.
Cable Connection: Make sure that the RS485/422 cable are connected
correctly to the camera devices.
- Before installation and mentainence, make sure that the keyboard is
disconnected from the power source.
With the keyboard, you can activate or setup the integrated function of
connected camera device. For the supported functions, please refer to
camera’s manual for further details.
Recall / activate Preset position
Please make sure that the following chapters are set correctly:
A(+)
B(+)
PTZ related functions
RS-485
up to 32 Devices
DO NOT CONNECT THE RJ-45 PORT
TO ANY COMPUTER NETWORK
INTERFACE, as this may cause serious
damage to the keyboard.
The LCD back-light will be turned off automatically after 15 seconds of
idle time.
PT Operation with Joystick
Move the joystick up, down, left and right to perform pan or tilt
operation. Depends on the angle of stick, the keyboard changes the
speed of PT movement. On performing the PT action, the LCD will
show the current movement with arrow signs
Zoom operation
The keyboard provides camera function keys with following function:
Wide / Tele: Zoom-out and zoom-in
Far / Near: Manual focus control
Open / Close: Manual Iris control
Matrix related functions
Switching the input channel.
Press [PREV] : switch to previous channel
Press [NEXT] : switch to next channel
Auto switching sequence
Press [PREV] for 2 sec.: Sequence in rev. order
Press [NEXT] for 2 sec.: Sequence to next channel.
Press [STOP] to stop the sequencel.
Open matrix configuration menu
Press [SHIFT] + [SET] to enter the menu and show on main
monitor. For the menu details, please refer to the users manual of
the matrix.
Confirm changes
Press [ENTER] after every changes in the menu.
Change target monitor
Press [n] + [MON] to change the selected device in the matrix.
Keyboard Menu
Dome setup > set dome scan
Keyboard setup
Set KB Parameter
1、Set KB Parameter
2、About keyboard
1、Keyboard setup
2、Dome setup
3、Protocol select
4、Exit menu
About keyboard
Dome setup >Set dome pattern
Set dome preset
preset
scan
pattern
tour
Press enter sure
Press prev to back
Press prev to back
Set pattern
Success!
Insert preset
Run tour
1、Preset num:
2、Speed:
3、Dwell:
Matrix
Success!
1. Tour num:_
2. Insert preset
3. Run tour
Pelco matrix
Success!
Enter the keyboard menu
To enter the keyboard’s setup menu, keep the [SET]-Key pressed for 2
seconds, To navigate through the menu items, use the joystick with “up”
and “down” to move between the items. Use “right” to enter the item or
confirm changes. Use “left” to leave the item or discard changes”
Main Menu
1 .Keyboard setup
2 .Dome setup
3 .Protocol select
4 .Exit menu
In main menu, you can select the
items by pressing the digit key, or use
joystick to navigate through the items.
For returning to upper menu level,
press [PREV] key. Use the [ENTER]
key to confirm the changes. The display will show “SUCCESS” when
changes are accepted.
Keyboard Setup
1. Set KB Parameter
2. About keyboard
Initial setup for the keyboard, such as
keyboard ID, and baud-rate. Press
digit key to enter.
Keyboard Setup > Set KB Parameter
Setup keyboards ID, Baud-rate and
1. Set KB ID
calibrates the joystick.
2. Set baudrate
Joystick up/down to select item
3. Joy_calibrate
[ENTER] to enter the sub-menu
[PREV] return to upper level.
Keyboard Setup > Set KB Parameter> Set KB ID
Use the digit keys to enter the ID, and
Input KB ID:
press [ENTER] to confirm. LCD will
(1 - 64)
show “SUCCESS” when accepted, or
“ERROR” if the ID input exceeds the
range.
1: Press the digit and [ENTER] to select
the tour number.
2: Add defined preset position to the tour
3: start the selected tour
Dome setup >Set dome tour> Insert preset
1. Preset num:_ select the defined preset
1. Preset num:_
position ( 1 - 80)
2. Speed:
2. Speed: PTZ moving speed to this
3. Dwell:
preset, 1 - 8 ( fastest)
3. Dwell: Stop time on this preset. Max. 60
seconds.
Dome
1、Factory
2、Pelco-P
3、Pelco-D
4、B02
Dome setup >Set dome pattern > Set pattern
Press 1 to start the pattern recording. The
Press 1 to start
dome will now memorize your PTZ
Press 0 to stop
operation. When finished, press 0 to stop
Press PREV to back
the recording. Press [PREV] to exit the
menu
Dome setup >Set dome tour
Success!
1、Pelco matrix
1: Press the digit and [ENTER] to select
the pattern number.
2: Sub-menu for pattern setup.
3: start the selected pattern
Run scan
Run pattern
Press 1 to start
Press 0 to stop
Press prev to back
Set dome tour
Protocol select
Set right limit
Press enter sure
Set dome pattern
1、Tour num:
2、Insert preset
3、Run tour
1. Pattern num:_
2. Set pattern
3. Run pattern
Press prev to back
Set left limit
1、Pattern num:
2、Set pattern
3、Run pattern
1、Matrix
2、Dome
Preset num:
1、Save preset
2、Show preset
3、Clear preset
Set dome scan
CamID:001 MonID:001
Protocol:Pelco-P
Baudrate:9600
Press PREV to back
Press ENTER
1、Set left limit
2、Set right limit
3、Run scan
Exit menu
Setup the 2-Points scan, select 1. And 2.
To define the left and right limit. Select
option nr. 3. To run the scan
Dome setup >set dome scan> set left, right limit
Move the Joystick to the desired position
Press ENTER sure
and press [ENTER] for confirmation.
1、Joy is free then
Dome setup
dome
dome
dome
dome
1、2400 bps
2、4800 bps
3、9600 bps
4、19200 bps
Joy_calibrate
Version:1.00
KB ID:008
Protocol:Factory
Baudrate:2400
1、Set
2、Set
3、Set
4、Set
Set baudrate
Set KB ID
Input KB ID:
1、Set KB ID:
2、Set baudrate
3、Joy_calibrate
1. Set left limit
2. Set right limit
3. Run Scan
Success!
Keyboard Setup > Set KB Parameter> set baudrate
Available baud rate. Move joystick “up’ or
2400 bps
“down” to select the setting and press
4800 bps
[ENTER] to confirm.
9600 bps
Press [PREV] to return to upper level.
19200 bps
Use the digit keys to change the value on every option, and press [ENTER]
to complete the insert action. The LCD will show “SUCCESS” to confirm the
preset, and returns to upper menu level.
1. Matrix
2. Dome
[N] + [CAM]
Select the connected
device
[TELE]
Zoom-In
[WIDE]
Zoom-Out
[FAR]
Manual focus far
[NEAR]
Manual focus near
[CLOSE]
Manual iris close
[OPEN]
Manual iris open
[SET]+[N]+[PRESET] Store current PTZ
position as preset
[N]+[PRESET]
Recall stored preset
position
[SET]+[1]+[SCAN]
Define current position
as the left limit for scan
[SET]+[2]+[SCAN]
define current position
as the right limit for
scan
[1]+[SCAN]
Start the scan
[SET]+[N]+[PATTERN] Start pattern recording
[SET]+[0]+[PATTERN] Stop the pattern
recording and store.
[N]+[PATTERN]
Start recorded pattern
[N]+[TOUR]
Start the defined tour.
Connection sample
Star-Connection with
RS-Distributor
Protocol select
Keyboard Setup > Set KB Parameter> Joy_calibrate
Release the joystick, and press [ENTER]
Joystick is free
to confirm the calibrate of zero-point .
then
Press [PREV] to return to upper level.
Quick Reference
1. Matrix: Matrix Mode
2. Dome: Setup Dome Protocol
press Enter
Max. 32 devices
(Keyboard and camera)
can be connected to a
RS-485 chain. E.g with 1
keyboard, you can max.
Connect 31 Speed
Domes.
RS-485
Distributor
Termination
Activated
on every dome
Protocol select >Matix
Keyboard Setup > About keyboard
Version: 1.00
KB ID: 001
Protocol: B01
Baudrate: 9600 bps
Information about current keyboard
setting. Press[PREV] to return.
1. Pelco Matrix
Currently only pelco protocol is supported
in the matrix mode. Press [ENTER] to exit.
Termination on RS-485 chain
RS 485+
RS 485-
Protocol > Dome
Keyboard
Dome setup
1. Set dome preset
2. Set dome scan
3. Set dome pattern
4. Set dome tour
Configure and setup the PTZ related
functions, such as preset, pattern... Etc.
1. Factory protocol
2. Pelco-P protocol
3. Pelco-D protocol
4. B02
Termination
On
Termination
On
For a multiple connection, you can
attach max. 4 keyboards to the
network. Make sure that every
keyboard has an unique ID.
Keyboard
Keyboard
Save, recall and clear the preset points.
Dome setup > Set dome preset> Save, show or clear preset
Enter the preset number with the digit key,
Preset num:
For saving preset, move the joystick and
press [ENTER]. To show or clear the
Press PREV to back
preset, enter the preset number and press
[ENTER], or press [PREV] to exit.
Termination
Off
Multiple device connection
Dome setup > Set dome preset
1. Save preset
2. Show preset
3. Clear preset
Termination
Off
Keyboard
DO NOT CONNECT THE RJ-45 PORT
TO ANY COMPUTER NETWORK
INTERFACE, as this may cause serious
damage to the keyboard.
Dome 1
Dome 2
Dome 3
Dome 4
Dome 5
Dome 6
Dome 7
Dome 8
Keyboard