SK 1-Waterproof
Dual-relay Access Control
INTRODUCTION
Keypad
12 Key (3*4)
The SK1 is a dual- entry multi-function Access Controller with integrated
keypad and card reader. It is designed and manufactured to perform in a wide
range of indoor, outdoor, and harsh environments.
Proximity Card Reader
Radio Technology
Read Range
EM
125 KHz Industry Standard Proximity Card
3-6cm
Wiring Connections
Electric Lock, Exit Button,
DOTL, External Alarm, Door Bell
Both of the two relays on board can operate in Pulse Mode (suitable for
access control) or Toggle Mode (suitable for arming/disarming alarms,
switching lights, machines….etc)
Relay
Adjustable Relay Output Time
Adjustable Alarm Output Time
Lock Output Load
Alarm Output Load
Two (NO, NC, COM)
1-99 Seconds (5 seconds default)
1-3 minutes (1 minute default)
3 Amp Maximum
3 Amp Maximum
The SK1 offers advanced programming features like: block enrollment,
advanced relay programming, and door bell.These features make it an ideal
choice for door access not only for small shops and domestic households but
also for commercial and industrial applications such as factories, warehouses,
laboratories, banks and prisons.
Environment
Operating Temperature
Operating Humidity
Meets IP66
-30℃~60℃,or -22°F~140°F
10%~90% Non-Condensing
Physical
Surface Finish
Dimensions
Unit Weight
Shipping Weight
Zinc-Alloy Enclosure
Powder Coat
L 120 X W 76 X H 25 (mm)
600g
700g
The SK1 supports up to 1100 users in multiple access configurations (Card,
PIN, or Card + PIN). The built in card reader supports EM 125KHz frequency
cards.
Features
> Waterproof(IP66)
> Vandal Resistant Enclosure
> Backlit Keypad
> Multi-color LED status display
> Two Programmable Relay Output
> 1100 Users (Card/PIN/ Card+PIN)
> Card Block enrollment
> Integrated Alarm Buzzer & Output
> Low power consumption (55mA)
> Anti-Tamper Alarm
> Latch Mode to hold door or gate open
> Relay 2 supports external door bell
> 12-24V DC/12-18V AC Power input
Wiring
Wall Anchors
Manager Card
INSTALLATION
> Remove the back cover from the unit
> Drill 2 holes(A,C) on the wall for the screws and one hole for the cable
> Knock the supplied rubber bungs to the screw holes(A,C)
> Fix the back cover firmly on the wall with 4 flat head screws
> Thread the cable through the cable hole(B)
> Attach the unit to the back cover.
User Manual
Programming Step
Grey&Black
SET ACCESS CONFIGURATION
> Card or PIN (Default): The User must present a valid Card to the SK1 or
enter their PIN code followed by the # key, in order to be granted access.
> Card + PIN: The User must first present a valid Card to the SK1 and then
enter their PIN code followed by the # key, in order to be granted access.
Programming Step
(Master Code) #
2.Card or PIN
Zone 1
Zone 2
OR
2.Card + PIN
Zone 1
Zone 2
410#
420#
411#
421#
3. Exit Program Mode
User Settings
To enter the programming mode
Master code #
To exit from the programming mode
Note that to undertake the following programming, the master user
must be logged in
Note:
When adding users, if the Card or Pin user has been enrolled already, you
can not add it again on the same zone, or the device will give a bleep as
error. But it is ok to enroll the same card or Pin for the both zones.
Factory default setting: Card or PIN mode
1
0
# )
Yellow & Black
OPEN2
Yellow
OPEN1
Brown
D_IN
B
Self Tapping Screws
To delete PIN users
Keystroke Combination
1. Enter Program Mode
ALARM
To change the PIN of a PIN user
(Note: This step must be done out
of programming mode)
To add Card Users. (Method 1)
This is an easy way to enter cards
with auto-generated ID numbers.
The ID number will start from 1 if no
user has been programmed
Connect the negative pole of the lock to NC is for Fail –safe lock.
Connect the negative pole of the lock to NO is for Fail-secure lock.
FUNCTION DESCRIPTION
Relay operation (Pulse mode and Toggle mode)
Both of the two relays on board can operate in Pulse Mode (suitable for
access control) or Toggle Mode (suitable for arming/disarming alarms,
switching lights, machines….etc)
SK1- Simplified Instruction
Function Description
Operation
Enter the Programming Mode
(Master Code) #
(666666 is the default factory
master code)
Change the Master Code
0 (New Master Code) # (Repeat
New Master Code) # (code: 4-6
digits)
Add Card User
1 (Read Card) # ( for Zone 1)
2 (Read Card) # ( for Zone 2)
Add PIN User
1 (User ID 1~1000) # (PIN)#
( for Zone 1)
1 (User ID 1001 ~1100) # (PIN) #
( for Zone 2)
The PIN is any 4-6 digits between
0000 ~ 999999
Configure the Keypad
Change the configure settings according to your application (optional).
Multiple configuration settings can be changed at one time: enter program
mode, change desired settings, then exit program mode.
Delete User
3 (Read Card) #
3 (User ID) #
Set Master Code
The 4-6 digit Master Code is used to prevent unauthorized access to the
system. To interface with the SK1, the manager will need a Master Code
(factory default code: 666666). We highly recommend immediate update
and recording of your Master Code.
Card User
Every time a valid tag/card read or Pin input in Pulse Mode, the relay will
operate, for the pre-set relay pulse time.
Every time a valid tag/card read or Pin input in Toggle Mode, the relay
changes state, which will not turn back until read card or input pin again.
Master Card
SK1 master can use master cards to program user cards into and out of the
system. There are two pre-programmed master cards (an Add Card, and a
Delete Card) to allow rapid card enrollment. It is for Zone 1 only.
1 User ID number # PIN #
The ID number is any number
from 1~ 1000.
The PIN is any 4~6 digits between
0000~999999 with the exception of
1234 which is reserved. Users can
be added continuously without
exiting programming mode as
follows: 1 User ID no 1 # PIN
# User ID no 2 # PIN #
3 User ID number #
Users can be deleted continuously
without exiting programming mode.
ID number # Old PIN #
New PIN # Repeat new PIN #
1 Read card #
Card can be added continuously
without exiting programming mode.
To delete Card users by user ID.
This option can be used when a
user has lost their card.
3 User ID #
9 Input 8 digits or 10 digits Card
number #
Cards can be deleted continuously
without exiting from programming
mode.
To delete card users by card
number
To set users for Zone 2. ( 4
2
0
# )
To set Pin user for Zone 2 is the same as Zone 1, only the ID number is
1001-1100 for Zone 2.
To set Card user for Zone 2 is the same as Zone 1, with the exception of
adding Card users with auto-generated ID numbers and Block enrolment
as below.
2 Read card #
Card can be added continuously
without exiting programming mode.
To add Card Users. (Method 1)
Auto-generated ID numbers.
C
To delete a Card and PIN user just
delete the card
To set users for Zone 2. ( 4 2 1 # )
The operation is the same as Zone 1.
To set Card user only.(in this mode, users can only be valid by card)
To set Card user only.
To set users for Zone 1. ( 4
1
1
1 ID number # Card #
The ID number can be any number
among 1~ 1000.
To add a series cards
users-Block Enrolment
The card number must be
consecutive.
(This operation is only for Zone 1)
1 ID number # 8 digits or 10
digits Card number #
Card quantity #
Card quantity is between 1-1000.
To change a PIN in card and PIN
mode (Method 1)
Note that this is done outside
programming mode so the user can
undertake this themselves
To delete Card users by cards.
Note: Users can be deleted
continuously without exiting
programming mode.
3 Read card #
The device can automatically
identify the card of Zone 1 or
Zone 2.
To change a PIN in card and PIN
mode (Method 2)
Note that this is done outside
programming mode so the user can
undertake this themselves
To Add a card and Pin user
(The PIN is any four digits between
0000 & 999999 with the exception
of 1234 which is reserved.)
4 1 2 # , Zone 1
4 2 2 # , Zone 2
Entry is by Card only
Red
AC&DC
Black
AC&DC
For Zone 1: 5 1 1~99 #
For Zone 2: 5 2 1~99 #
The door relay time is between
1~99 seconds, the factory default
setting is 5 seconds. 1 means
Zone 1. 2 means Zone 2.
# )
Add the card as for a card user
Press
to exit from the
programming mode
Then allocate the card a PIN as
follows:
Read card 1234 #
PIN # PIN #
Read Card Old PIN #
New PIN # New PIN #
ID number # Old PIN #
New PIN # New PIN #
Toggle mode
Toggle mode
For Zone 1: 5 1 0
For Zone 2: 5 2 0
#
#
Door, Alarm, Acoustic Signal, Door Bell Settings
Door Open Detection
Door Open Too Long (DOTL) warning. When used with an optional
magnetic contact or built-in magnetic contact of the lock, if the door is
opened normally, but not closed after 1 minute, the inside buzzer will beep
automatically to remind people to close the door and continue for 1 minute
before switching off automatically.
Door Forced Open warning. When used with an optional magnetic contact
or built-in magnetic contact of the lock, if the door is forced open, the inside
buzzer and alarm output will both operate.
To disable door open detection.
(Factory default setting)
6 0
#
PROGRAMMING
Door Status Detecting
+
Electric Lock
NO2
-
White & Black
COM2
Green & Black
NC2
NO 2
Blue
NO1
COM 2
White
COM1
Green
NC1
To enable door open detection
Diode
Door Bell
Door Bell installation & usage:
Connect door bell with wires:NO2 COM2.
Press ‘#’,the SK1 reader will
send outa signal to the door bell.
6 1 #
It is optional to connect the D_IN
line to LOCK1 or LOCK 2
Normal status: No keypad lockout
or alarm
7 0
Add a User Card
Keypad Lockout
7 1
7 2
# (Factory default setting)
#
#
To set the alarm output time (1-3
minutes) Factory default is 1 minute
Delete a User Card
8 1~3 #
Acoustic Signal
The acoustic signal can be set on or off. When on, the device will give the
voice when press the keys; when off, the device will be in silent.
Normal status: On
8 6
# (Factory default setting)
Acoustic signal Off
8 7
#
Change Zone 2 to Door Bell
(When no need to operate a second door, Zone 2 can be set to operate
the Door Bell. The wiring is connecting the door bell to COM2 and NO2.
Press #, the keypad will send the signal to the door bell.
Zone 2
8 8
# (Factory default.)
Door bell
8 9
#
To remove the alarm
1. (Read Master Add Card)
2. (Read User Card)
Repeat Step 2 for additional user
cards
3. (Read Master Add Card)
1. (Read Master Delete Card)
2. (Read User Card)
Repeat Step 2 for additional user
cards
3. (Read Master Delete Card)
Reset to Factory Default:
This will reset the SK1 to the factory default but all card/PIN information will
still be retained. This will also require reprogramming of the Master Add and
Delete Cards. NOTE: This is useful if the original Master Add and Delete
Cards have been lost.
1. Power the SK1 down.
2. Press * and hold the button while power is restored to the keypad.
3. Release the button and wait until the amber LED shines.
4. Present any 125KHz proximity EM card or the Master Add Card (provided)
to the SK1. This card is now the Master Add Card.
5. Present any 125KHz proximity EM card or the Master Delete Card (provided)
to the SK1. This card is now the Master Delete Card.
When the red LED begins to blink, the SK1 has been successfully reset.
To reset the Door Forced Open
warning
Read valid card or Master Code #
To reset the Door Open Too Long
warning
Close the door or Read valid card
or Master Code #
How to be granted access.
Read card
Enter (PIN) #
PIN User
Operation Status
Using Master Cards
Keypad Lockout & Alarm Output options. If there are 10 invalid cards
or 10 incorrect PIN numbers in a 10 minute period either the keypad will
lockout for 10 minutes or the alarm will operate for 10 minutes, depending
on the option selected below.
Exit from the programming mode
Sound and Light Indication
OTHERS
Using Master Card
(It is only available for Zone 1)
Alarm output time
Pulse mode (Factory default)
Pulse mode-Door relay time setting
Alarm
Exit Button of Zone 1
Alarm Output
Relay Setting (Pulse mode, Toggle mode)
Card and PIN Mode
To add Card Users. (Method 2)
This is the alternative way to enter
cards using User ID Allocation. In
this method a User ID is allocated
to a card. Only one user ID can be
allocated to a single card.
3 Read Card # or 3 User ID #
Anti Tamper Alarm
The SK1 uses a LDR (light dependent resistor) as an anti tamper alarm.
If the keypad is removed from the cover then the tamper alarm will operate.
+
-
Exit Button of Zone 2
A
SK1 Access Controller
12~24V DC / 12~18V AC
55mA
80mA
To add PIN users
Power
12-24V DC/12-18V AC/5A
GND
Grey
Blue & Black
0 ( New Master Code) #
( Repeat New Master Code) #
3. Exit Program Mode
Connection Diagram
Remarks: the Zone 2, it can be used to operate the door bell when no need
to operate a second door. The wiring is connecting the door bell to NO2 and.
COM2. Press #, the keypad will send out a switching signal to the door bell, as
long as you press the” #”, the door bell will continuous operate, it will stop
until you release the ” #”
Carton Inventory
Diode IN4004 (For relay circuit protection)
(Master Code) #
2. Update Master Code
Blue&Black
White&Black
Green&Black
Yellow&Black
Grey
Brown
SK 1
1100 Cards/PINS
1000
100
Keystroke Combination
1. Enter Program Mode
To set users for Zone 1. ( 4
Operating Voltage
Idle Current
Active Current
Notes
Basic Standalone Wiring
AC&DC 12~24V DC/12-18V AC Regulated Power Input
AC&DC 12~24V DC/12-18V AC Regulated Power Input
Negative Pole
GND
Normally Open Relay 1 output
NO 1
Common Connection for Relay 1 output
COM1
Normally closed Relay 1 Output
NC 1
OPEN1 Request to Exit input 1(REX)
Advanced Input and Output Features
Normally Open Relay 2 Output
NO 2
Common Connection for Relay 2 Output
COM2
Normally closed Relay 2 Output
NC 2
OPEN2 Request to Exit input 2(REX)
Alarm Negative
Alarm
Door status detecting
D_IN
Red
Black
Grey&Black
Blue
White
Green
Yellow
Screw Driver
Specifications
User Capacity
Zone 1
Zone 2
Function
Wire Color
Erase all Users
This will delete ALL User data of Zone1 or Zone 2 or Both.
1, Enter Program Mode by press: *(Master Code) #.
2, Press 30000 # (for Zone 1)
Or
2, Press 90000 # (for Zone 2)
3, Exit: *
All configuration data is retained.
Power on
Stand by
Press Keypad
Red LED
Flashing
Flashing
Flashing
Enter Master
Code Entry Mode
ON
In program mode
ON
Single Flash
Short Single Beep
Entered Program
Step Successfully
ON
Single Flash
Short Single Beep
Green LED
Bule LED
Short Single Beep
Short Single Beep
Entered Program
Step Incorrectly
Exit from the
programming mode
3 Short Beeps
Flashing
Entry Granted for
Zone 1
Short Single Beep
Short Single Beep
ON
Entry Granted for
Zone 2
Alarm Mode
Engaged
Sounds
Short Single Beep
ON
Flashing
Alarm