Shenzhen Anbotek Compliance Laboratory Limited
Page 1 of 49 Report No. R011412646S
APPLICATION FOR R&TTE DIRECTIVE
On Behalf of
TBS Avionics Co. Limited
Video Transmitter
Model: TBS GREENHORN
Prepared For
: TBS Avionics Co. Limited
Room G, 4/F, Winner Factory Building, No.55 Hung To Road,
Kwun Tong, Kln, HK
Prepared By
: Shenzhen Anbotek Compliance Laboratory Limited
1/F., Building 1, SEC Industrial Park, No.0409 Qianhai Road,
Nanshan District, Shenzhen, Guangdong, China
Tel:
Fax:
(86)755-26066544
(86)755-26014772
Date of Test:
Dec. 25, 2014 to Jan. 20, 2015
Date of Report:
Jan. 20, 2015
Report Number:
R011412646S
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
Page 3 of 49 Report No. R011412646S
Test item particulars.................................................. : Video Transmitter
Equipment mobility ....................................................:
Movable
Stationary
Hand-held
For building-in
Connection to the mains............................................:
Pluggable equipment
Type A
Type B
Permanent connection
Detachable power supply cord
Non-detachable power supply cord
Not directly connected to the mains
built-in component, consider in end system
Operating condition ...................................................:
Continuous
Rated operating / resting time:
Over voltage category (OVC) ...................................... :
OVC I
Other:
OVC II
Tested for IT power systems ....................................... :
Yes
No
OVC III
Transportable
Direct plug-in
OVC IV
IT testing, phase-phase voltage (V) ............................ : N.A.
Class of equipment ...................................................... :
Class I
Class II
Not classified
Class III
Considered current rating (A) ...................................... :
Pollution degree (PD) ................................................... :
PD 1
PD 2
PD 3
IP protection class ........................................................ : IPX0
Altitude during operation (m) ....................................... : 2000
Altitude of test laboratory (m) ................................... : <500
Mass of equipment (kg) ............................................ : 1.12
Possible test case verdicts:
- test case does not apply to the test object................. : N(.A.)
- test object does meet the requirement....................... : P (Pass)
- test object does not meet the requirement................. : F (Fail)
Testing.......................................................................... :
Date of receipt of test item ............................................ : Dec. 25, 2014
Date(s) of performance of tests .................................... : Dec. 25, 2014 to Jan. 20, 2015
General remarks
This test report shall not be reproduced except in full without the written approval of the testing laboratory.
The test results presented in this report relate only to the item tested.
"(see remark #)" refers to a remark appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report a comma is used as the decimal separator.
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
Page 4 of 49 Report No. R011412646S
Remark:
1. The EUT for supplying information technology equipment.
2. Clearance was evaluated for altitude up to 2000m above sea level.
3. The maximum ambient temperature is 40℃.
Copy of marking plate (s):
Video Transmitter
Model: TBS GREENHORN
Rating: DC 5V
2280
TBS Avionics Co. Limited
Summary of testing
Rubbing for 15 s with a piece of cloth soaked with water. And a further 15 s with a piece of cloth soaked
with petroleum.
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
Page 5 of 49 Report No. R011412646S
EN 60950-1/Am1
Clause
Requirement – Test
1
GENERAL
P
1.5
Components
P
1.5.1
General
P
Comply with IEC 60950 or relevant component
standard
Result - Remark
Components, which were
found to affect safety aspects
comply with the requirements
of this aspects of the relevant
IEC component standards.
(See appended table 1.5.1)
Verdict
P
1.5.2
Evaluation and testing of components
1.5.3
Thermal controls
1.5.4
Transformers
1.5.5
Interconnecting cables
No interconnecting cable
provided.
N
1.5.6
Capacitors bridging insulation
No such capacitors used.
N
1.5.7
Resistors bridging insulation
N
1.5.7.1
Resistors bridging functional insulation, basic
insulation or supplementary insulation
Resistors bridging double insulation or reinforced
insulation between the a.c. mains supply and
other circuits
Resistors bridging double insulation or reinforced No bridging resistors.
insulation between the a.c. mains supply and
circuits connected to an antenna or coaxial cable
N
1.5.7.2
1.5.7.3
P
No thermal controls provided
N
N
TN power system.
N
N
1.5.8
Components in equipment for IT power systems
1.5.9
Surge suppressor
N
1.5.9.1
General
N
1.5.9.2
Protection of VDRs
N
1.5.9.3
Bridging of functional insulation by a VDR
N
1.5.9.4
Bridging of basic insulation by a VDR
N
1.5.9.5
Bridging of supplementary, double or reinforced
by a VDR
N
1.6
Power interface
P
1.6.1
AC power distribution systems
N
1.6.2
Input current
1.6.3
Voltage limit of hand-held equipment
1.6.4
Neutral conductor
(see appended table 1.6.2)
N
P
P
Class III equipment
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
N
Shenzhen Anbotek Compliance Laboratory Limited
Page 6 of 49 Report No. R011412646S
EN 60950-1/Am1
Clause
Requirement – Test
Result - Remark
Verdict
1.7
Marking and instructions
1.7.1
Power rating
See below
P
Rated voltage(s) or voltage range(s) (V) ............:
DC 5V
P
P
Symbol for nature of supply, for d.c. only ...........:
P
Rated frequency or frequency range (Hz)
:
N
Rated current (mA or A) .....................................:
P
Manufacturer’s name or trademark or
identification marks .............................................:
TBS Avionics Co. Limited
Type/model .........................................................:
TBS GREENHORN
P
Symbol of Class II equipment only .....................:
Class III equipment
N
P
Other symbols ....................................................:
N
Certification marks ..............................................:
P
1.7.2
Safety instructions
See user manual
P
1.7.3
Short duty cycles
Equipment is designed for
continuous operation.
N
1.7.4
Supply voltage adjustment .................................:
Input not adjustable.
N
Methods and means of adjustment; reference to
installation instructions ........................................:
--
1.7.5
Power outlets on the equipment .........................:
No power outlets on the
equipment.
N
1.7.6
Fuse identification (marking, special fusing
characteristics, cross-reference) ........................:
No such device within the
EUT
N
1.7.7
Wiring terminals
Class III equipment
N
1.7.7.1
Protective earthing and bonding terminals
1.7.7.2
Terminal for a.c. mains supply conductors
1.7.7.3
Terminal for d.c. mains supply conductors
N
1.7.8
Controls and indicators
P
1.7.8.1
Identification, location and marking
1.7.8.2
Colours
P
1.7.8.3
Symbols according to IEC 60417
N
1.7.8.4
Markings using figures
N
1.7.9
Isolation of multiple power sources
Only one supply voltage
provided.
N
1.7.10
Thermostats and other regulating devices
No such components.
N
N
No such terminal used except
separately approved switch
power supply.
No controls and identification.
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
N
N
Shenzhen Anbotek Compliance Laboratory Limited
Page 7 of 49 Report No. R011412646S
EN 60950-1/Am1
Clause
Requirement – Test
Result - Remark
1.7.11
Durability
The marking was rubbed with
cloth soaked with water for 15
sec. and then again for 15
sec. with the cloth soaked with
petroleum spirit.
Verdict
P
After this test, the marking still
legible and durable.(see
appended tables 1.7.11)
1.7.12
Removable parts
1.7.13
Replaceable batteries
No removable parts
N
P
Language.............................................................:
English
--
1.7.14
Equipment for restricted access locations...........:
Unit is not limited to be used
in restricted access locations.
N
2
PROTECTION FROM HAZARDS
--
2.1
Protection from electric shock and energy hazards
2.1.1
Protection in operator access areas
P
P
The EUT is Class III
equipment, no hazardous live
parts within the EUT
2.1.1.1
Access to energized parts
N
Test by inspection ...............................................:
N
Test with test finger ............................................:
N
Test with test pin .................................................:
N
Test with test probe ............................................:
2.1.1.2
Battery compartments .........................................:
2.1.1.3
Access to ELV wiring
No TNV present.
N
N
No ELV wiring in operator
accessible area.
Working voltage (Vpeak or Vrms); minimum
distance (mm) through insulation
N
--
2.1.1.4
Access to hazardous voltage circuit wiring
No hazardous voltage wiring
in operator accessible area.
N
2.1.1.5
Energy hazards ..................................................:
No energy hazard in operator
P
access area
2.1.1.6
Manual controls
2.1.1.7
Discharge of capacitors in equipment
2.1.1.8
N
Class III equipment
N
Time-constant (s); measured voltage (V)............:
--
Energy hazards d.c. mains supplies
N
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
Page 8 of 49 Report No. R011412646S
EN 60950-1/Am1
Clause
Requirement – Test
Result - Remark
Verdict
2.1.1.9
Audio amplifiers in information technology
equipment
2.1.2
Protection in service access areas
No service access area.
N
2.1.3
Protection in restricted access locations
No restricted access location.
N
2.2
SELV circuits
--
2.2.1
General requirements
P
2.2.2
Voltages under normal conditions (V) …………..:
N
Not exceed 60V dc in SELV
P
circuit
2.2.3
Voltages under fault conditions (V) .....................:
Not exceed 60V dc in SELV
P
circuit
2.2.3.1
Separation by double insulation or reinforced
insulation (method 1)
2.2.3.2
Separation by earthed screen (method 2)
N
2.2.3.3
Protection by earthing of the SELV circuit (method
3)
N
2.2.4
Connection of SELV circuits to other circuits ... :
2.3
TNV circuits
N
2.3.1
Limits
N
Type of TNV circuits ............................................:
N
Separation from other circuits and from
accessible parts
N
Insulation employed ............................................:
N
Separation from hazardous voltages
N
Insulation employed ............................................:
N
Connection of TNV circuits to other circuits
N
Insulation employed ............................................:
N
2.3.5
Test for operating voltages generated externally
N
2.4
Limited current circuits
N
2.4.1
General requirements
N
2.4.2
Limit values
N
Frequency (Hz)....................................................:
--
Measured current (mA) .......................................:
--
2.3.2
2.3.3
2.3.4
Method 1 used. SELV
separate from primary by
reinforced or double insulation.
SELV circuit only for
connection to other SELV
circuits.
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
N
P
Shenzhen Anbotek Compliance Laboratory Limited
Page 9 of 49 Report No. R011412646S
EN 60950-1/Am1
Clause
Requirement – Test
Result - Remark
Verdict
Measured voltage (V) ..........................................:
--
Measured capacitance (F) ................................:
--
2.4.3
Connection of limited current circuits to other
circuits
2.5
Limited power sources
---
Inherently limited output
N
Impedance limited output
N
Overcurrent protective device limited output
N
Regulating network limited output under normal
operating and single fault condition
N
Regulating network limited output under normal
operating conditions and overcurrent protective
device limited output under single fault condition
N
Output voltage (V), output current (A), apparent
power (VA)......................................................... :
N
Current rating of overcurrent protective device (A)
N
2.6
Provisions for earthing and bonding
--
2.6.1
Protective earthing
2.6.2
Functional earthing
N
2.6.3
Protective earthing and protective bonding
conductors
N
2.6.3.1
General
N
2.6.3.2
Size of protective earthing conductors
N
Rated current (A), cross-sectional area (mm2),
AWG ....................................................................:
--
2.6.3.3
Size of protective bonding conductors
Only intended to be
connected with SELV circuits
Class III equipment
See below
Rated current (A), cross-sectional area (mm2),
AWG ....................................................................:
N
N
N
--
2.6.3.4
Resistance (Ω) of earthing conductors and their
terminations, test current(A)
2.6.3.5
Colour of insulation..............................................:
N
2.6.4
Terminals
N
2.6.4.1
General
N
2.6.4.2
Protective earthing and bonding terminals
N
Rated current (A), type and nominal thread
diameter (mm) .....................................................:
--
See appended table 2.6.3.3
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
N
Shenzhen Anbotek Compliance Laboratory Limited
Page 10 of 49 Report No. R011412646S
EN 60950-1/Am1
Clause
Requirement – Test
Result - Remark
2.6.4.3
Separation of the protective earthing conductor
from protective bonding conductors
N
2.6.5
Integrity of protective earthing
N
2.6.5.1
Interconnection of equipment
N
2.6.5.2
Components in protective earthing conductors
and protective bonding conductors
N
2.6.5.3
Disconnection of protective earth
N
2.6.5.4
Parts that can be removed by an operator
N
2.6.5.5
Parts removed during servicing
N
2.6.5.6
Corrosion resistance
2.6.5.7
Screws for protective bonding
N
2.6.5.8
Reliance on telecommunication network or cable
distribution system
N
2.7
Overcurrent and earth fault protection in primary circuits
--
2.7.1
Basic requirements
N
Instructions when protection relies on building
installation
N
2.7.2
Faults not covered in 5.3
N
2.7.3
Short-circuit backup protection
N
2.7.4
Number and location of protective devices ........:
N
2.7.5
Protection by several devices
One protective device provided
N
2.7.6
Warning to service personnel..............................:
No service work necessary
N
2.8
Safety interlocks
2.8.1
General principles
2.8.2
Protection requirements
N
2.8.3
Inadvertent reactivation
N
2.8.4
Fail-safe operation
N
2.8.5
moving parts
N
2.8.6
Overriding
N
2.8.7
Switches and relays
N
2.8.7.1
Contact gaps (mm) .............................................:
N
2.8.7.2
Overload test
N
All safety earthing
connections in compliance
with Annex J.
Verdict
N
N
No safety interlocks.
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
N
Shenzhen Anbotek Compliance Laboratory Limited
Page 11 of 49 Report No. R011412646S
EN 60950-1/Am1
Clause
Requirement – Test
Result - Remark
2.8.7.3
Endurance test
N
2.8.7.4
Electric strength test (V)
N
2.8.8
Mechanical actuators
N
2.9
Electrical insulation
P
2.9.1
Properties of insulating materials
P
2.9.2
Humidity conditioning
48h
Verdict
P
Relative humidity (%), temperature (°C) ..............: 93%RH, 30°C
--
2.9.3
Grade of insulation
P
2.9.4
Separation from hazardous voltages
N
Method(s) used ....................................................:
--
2.10
Clearances, creepage distances and distances through insulation
P
2.10.1
General
N
2.10.2
Determination of working voltage
Considered
N
2.10.3
Clearances
Annex F and minimum
clearances considered
N
2.10.3.1
General
N
2.10.3.2
Mains transient voltages
N
2.10.3.3
Clearances in primary circuit
N
2.10.3.4
Clearances in secondary circuits
N
2.10.3.9
Measurement of transient voltage
2.10.4
Creepage distances
CTI tests ..............................................................:
Reinforced, double,
supplementary, basic and
functional insulation
Normal transient voltage
considered
N
P
CTI rating for all materials of
min.100.
--
2.10.5
Solid insulation
N
2.10.5.1
General
N
2.10.5.2
Distance through insulation
N
2.10.5.3
Insulating compound as solid insulation
N
2.10.5.4
Semiconductor devices
N
2.10.5.5
Cemented joints
N
2.10.5.6
Thin sheet material
N
Number of layers (pcs) ........................................:
N
Electric strength test
--
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
Page 12 of 49 Report No. R011412646S
EN 60950-1/Am1
Clause
Requirement – Test
2.10.5.7
Separable thin sheet material
N
2.10.5.8
Non-separable thin sheet material
N
2.10.5.9
Thin sheet material – standard test procedure
N
2.10.5.10
Thin sheet material – alternative test procedure
N
2.10.5.11
Insulation in wound components
N
2.10.5.12
Wound components
N
Number of layers (pcs) ........................................:
N
Two wires in contact inside component; angle
between 45 and 90
N
2.10.5.13
Wire with solvent –based enamel in wound
component
N
2.10.5.14
Additional insulation in would components
N
2.10.6
Construction of printed boards
N
2.10.6.1
Uncoated printed boards
P
2.10.6.2
Coated printed boards
N
2.10.6.3
Insulation between conductors on the same inner
surface of a printed board
N
2.10.6.4
Insulation between conductors on the different
surface of a printed board
N
2.10.7
Component external terminations
2.10.8
Tests on coated printed boards and coated
components
N
2.10.8.1
Sample preparation and preliminary inspection
N
2.10.8.2
Thermal conditioning
N
2.10.8.3
Electric strength test
N
2.10.8.4
Abrasion resistance test
N
2.10.9
Thermal cycling
N
2.10.10
Test for Pollution Degree 1 environment and for
insulating compound
Tests for semiconductor devices and for
cemented joints
N
2.10.12
Enclosed and sealed parts
N
3
WIRING, CONNECTIONS AND SUPPLY
P
3.1
General
N
3.1.1
Current rating and overcurrent protection
N
3.1.2
Protection against mechanical damage
2.10.11
Result - Remark
No such components
Verdict
N
N
Smooth wireways
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
P
Shenzhen Anbotek Compliance Laboratory Limited
Page 13 of 49 Report No. R011412646S
EN 60950-1/Am1
Clause
Requirement – Test
Result - Remark
3.1.3
Securing of internal wiring
All internal wirings are suitable
Verdict
P
fixed
3.1.4
Insulation of conductors
N
3.1.5
Beads and ceramic insulators
N
3.1.6
Screws for electrical contact pressure
N
3.1.7
Insulating materials in electrical connections
N
3.1.8
Self-tapping and spaced thread screws
N
3.1.9
Termination of conductors
N
10 N pull test
N
3.1.10
Sleeving on wiring
N
3.2
Connection to an a.c. mains supplies or a d.c. mains supply
N
3.2.1
Means of connection ..........................................:
N
3.2.1.1
Connection to an a.c. mains supply
N
3.2.1.2
Connection to a d.c. mains supply
N
3.2.2
Multiple supply connections
N
3.2.3
Permanently connected equipment
Unit is not a permanently
connected equipment.
Number of conductors, diameter (mm) of cable
and conduits .......................................................:
N
--
3.2.4
Appliance inlets
No appliance inlets
3.2.5
Power supply cords
N
3.2.5.1
AC power supply cords
--
Type.....................................................................:
N
--
2
Rated current (A), cross-sectional area (mm ),
AWG ................................................................... :
N
3.2.5.2
DC power supply cords
N
3.2.6
Cord anchorages and strain relief
See below
N
Mass of equipment (kg), pull (N) ...................... :
N
Longitudinal displacement (mm) ....................... :
--
3.2.7
Protection against mechanical damage
--
3.2.8
Cord guards
N
D (mm); test mass (g) ........................................ :
N
Radius of curvature of cord (mm)....................... :
N
Supply wiring space
N
3.2.9
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
Page 14 of 49 Report No. R011412646S
EN 60950-1/Am1
Clause
Requirement – Test
3.3
Wiring terminals for connection of external conductors
N
3.3.1
Wiring terminals
N
3.3.2
Connection of non-detachable power supply
cords
N
3.3.3
Screw terminals
N
3.3.4
Conductor sizes to be connected
N
Rated current (A), cord/cable type, crosssectional area (mm2) ...........................................:
--
Wiring terminal sizes
N
Rated current (A), type and nominal thread
diameter (mm) .....................................................:
--
3.3.6
Wiring terminals design
N
3.3.7
Grouping of wiring terminals
N
3.3.8
Stranded wire
N
3.4
Disconnection from the mains supply
N
3.4.1
General requirement
N
3.4.2
Disconnect device
N
3.4.3
Permanently connected equipment
N
3.4.4
Parts which remain energized
N
3.4.5
Switches in flexible cords
N
3.4.6
Single-phase equipment and d.c. equipment
N
3.4.7
Three-phase equipment
N
3.4.8
Switches as disconnect devices
N
3.4.9
Plugs as disconnect devices
N
3.4.10
Interconnected equipment
N
3.4.11
Multiple power sources
N
3.5
Interconnection of equipment
P
3.5.1
General requirements
3.5.2
Types of interconnection circuits ..........................: Interconnection circuits of
SELV through the output
connectors. No ELV
interconnection circuits.
P
3.5.3
ELV circuits as interconnection circuits
N
3.5.4
Data ports for additional equipement
3.3.5
Result - Remark
See below
No ELV interconnection.
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Verdict
P
N
Shenzhen Anbotek Compliance Laboratory Limited
Page 15 of 49 Report No. R011412646S
EN 60950-1/Am1
Clause
Requirement – Test
4
PHYSICAL REQUIREMENTS
N
4.1
Stability
--
Angle of 10
Result - Remark
Consider in end system
Verdict
N
Test: force (N).......................................................:
N
4.2
Mechanical strength
P
4.2.1
General
4.2.2
Steady force test, 10 N
N
4.2.3
Steady force test, 30 N
N
4.2.4
Steady force test, 250 N
N
4.2.5
Impact test
P
Fall test
P
Swing test
N
See below. After tests,
equipment complied with
2.1.1, 2.6.1, 2.10 and 4.4.1.
P
4.2.6
Drop test
1000mm
P
4.2.7
Stress relief test
70 °C, all the enclosure
P
materials listed in the table
1.5.1 are tested
4.2.8
Cathode ray tubes
No CRT in the unit.
Picture tube separately certified ......................... :
N
N
4.2.9
High pressure lamps
No high pressure lamps.
4.2.10
Wall or ceiling mounted equipment; force (N) ... :
N
4.3
Design and construction
P
4.3.1
Edges and corners
P
4.3.2
Handles and manual controls; force (N)............. :
No such device within the
EUT
N
4.3.3
Adjustable controls
No adjustable controls.
N
4.3.4
Securing of parts
N
4.3.5
Connection of plugs and sockets
N
4.3.6
Direct plug-in equipment
The EUT is not direct plug-in
N
N
equipment
Dimensions (mm) of mains plug for direct plug-in
............................................................................. .
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
N
Shenzhen Anbotek Compliance Laboratory Limited
Page 16 of 49 Report No. R011412646S
EN 60950-1/Am1
Clause
Requirement – Test
Result - Remark
Torque and pull test of mains plug for direct plugin; torque (Nm); pull (N) ..................................... :
Verdict
N
4.3.7
Heating elements in earthed equipment
No heating elements
provided.
N
4.3.8
Batteries
No battery
N
- Overcharging of a rechargeable battery
N
- Unintentional charging of a non-rechargeable
battery
N
- Reverse charging of a rechargeable battery
N
- Excessive discharging rate for any battery
N
4.3.9
Oil and grease
Insulation in intended use not
considered to be exposed to
oil or grease.
N
4.3.10
Dust, powders, liquids and gases
Equipment in intended use not
considered to be exposed to
these substances.
N
4.3.11
Containers for liquids or gases
No container for liquids or
gases provided.
N
4.3.12
Flammable liquids............................................... :
No flammable liquids
provided.
N
Quantity of liquid (l)............................................. :
--
Flash point (C) .................................................. :
--
4.3.13
Radiation; type of radiation ................................ :
4.3.13.1
General
4.3.13.2
Ionizing radiation
4.3.13.3
4.3.13.5
LED as indicating light
P
N
No ionising radiation.
N
Measured radiation (pA/kg) ............................... :
--
Measured high-voltage (kV) .............................. :
--
Measured focus voltage (kV) ............................. :
--
CRT markings..................................................... :
--
Effect of ultraviolet (UV) radiation on materials
No UV radiation.
N
Part, property, retention after test, flammability
classification ....................................................... :
--
Human exposure to ultraviolet (UV)radiation ..... :
--
Laser (including LEDs)
P
Laser class ......................................................... :
Class I
--
4.3.13.6
Other types ......................................................... :
N
4.4
Protection against hazardous moving parts
N
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
Page 17 of 49 Report No. R011412646S
EN 60950-1/Am1
Clause
Requirement – Test
Result - Remark
4.4.1
General
No hazardous moving parts.
4.4.2
Protection in operator access areas
N
4.4.3
Protection in restricted access locations
N
4.4.4
Protection in service access areas
N
4.5
Thermal requirements
P
4.5.1
General
P
4.5.2
Temperature tests
See appended table 4.5.1
P
4.5.3
Temerature limits for materials
The equipment and its
component parts did not attain
excessive temperatures during
normal operation. (See
appended table 4.5.1)
P
4.5.4
Touch temperature limits
See appended table 4.5.1
P
4.5.5
Resistance to abnormal heat
See appended table 4.5.2
N
4.6
Openings in enclosures
N
4.6.1
Top and side openings
N
Dimensions (mm) .............................................. :
--
Bottoms of fire enclosures
N
Construction of the bottom ................................. :
N
4.6.3
Doors or covers in fire enclosures
N
4.6.4
Openings in transportable equipment
N
4.6.5
Adhesives for constructional purposes
N
Conditioning temperature(℃)/time (weeks) .......:
--
4.7
Resistance to fire
P
4.7.1
Reducing the risk of ignition and spread of flame
P
Method 1, selection and application of
components wiring and materials
P
Method 2, application of all of simulated fault
condition tests
N
4.7.2
Conditions for a fire enclosure
P
4.7.2.1
Parts requiring a fire enclosure
P
4.7.2.2
Parts not requiring a fire enclosure
N
4.7.3
Materials
--
4.7.3.1
General
P
4.6.2
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Verdict
N
Shenzhen Anbotek Compliance Laboratory Limited
Page 18 of 49 Report No. R011412646S
EN 60950-1/Am1
Clause
Requirement – Test
Result - Remark
4.7.3.2
Materials for fire enclosures
P
4.7.3.3
Materials for components and other parts outside
fire enclosures
P
4.7.3.4
Materials for components and other parts inside
fire enclosures
N
4.7.3.5
Materials for air filter assemblies
No air filter provided.
N
4.7.3.6
Materials used in high-voltage components
No high voltage components
provided.
N
5
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS
N
5.1
Touch current and protective conductor current
N
5.1.1
General
5.1.2
Equipment under test (EUT)
N
5.1.3
Test circuit
N
5.1.4
Application of measuring instrument
5.1.5
Test procedure
5.1.6
Test measurements
See sub-clauses 5.1.2 to 5.1.6
Equipment comply with Annex
D.
Verdict
N
N
N
See appended table 5.1.6.
P
Test voltage (V) ................................................. :
--
Measured current (mA) ..................................... :
--
Max. allowed current (mA) ................................ :
--
Measured protective conductor current (mA) .... :
--
Max. allowed protective conductor current (mA) :
--
5.1.7
Equipment with touch current exceeding
3.5 mA ............................................................. :
No test necessary.
5.1.8
Touch currents to and from telecommunication
No TNV circuit.
networks and cable distribution systems and from
telecommunication networks
N
5.1.8.1
Limitation of the touch current to a
telecommunication network and a cable
distributions system
N
Test voltage (V) ................................................. :
--
Measured touch current (mA) ............................ :
--
Max. allowed touch current (mA) ....................... :
--
5.1.8.2
Summation of touch currents from
telecommunication networks .............................. :
N
5.2
Electric strength
P
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
N
Shenzhen Anbotek Compliance Laboratory Limited
Page 19 of 49 Report No. R011412646S
EN 60950-1/Am1
Clause
Requirement – Test
Result - Remark
5.2.1
General
(see appended table 5.2)
P
5.2.2
Test procedure
(see appended table 5.2)
P
5.3
Abnormal operating and fault conditions
N
5.3.1
Protection against overload and abnormal
operation
N
5.3.2
Motors
N
5.3.3
Transformers
5.3.4
Functional insulation........................................... :
5.3.5
Electromechanical components
5.3.6
Audio amplifiers in information technology
equipment
N
5.3.7
Simulation of faults
N
5.3.8
Unattended equipment
5.3.9
Compliance criteria for abnormal operating and
fault conditions
N
6
CONNECTION TO TELECOMMUNICATION NETWORKS
N
6.1
Protection of telecommunication network service personnel, and users of other
equipment connected to the network, from hazards in the equipment
---
6.1.1
Protection from hazardous voltages
---
6.1.2
Separation of the telecommunication network from earth
---
6.1.2.1
Requirements
N
Test voltage (V) ................................................. :
Evaluated within has been
approved power supply
Verdict
N
N
No electromechanical
components.
None of the listed components
was provided.
1000V~
N
N
--
Current in the test circuit (mA) ......................... :
--
6.1.2.2
Exclusions .......................................................... :
N
6.2
Protection of equipment users from overvoltages on telecommunication
networks
N
6.2.1
Separation requirements
N
6.2.2
Electric strength test procedure
N
6.2.2.1
Impulse test
N
6.2.2.2
Steady-state test
N
6.2.2.3
Compliance criteria
N
6.3
Protection of telecommunication wiring system from overheating
N
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
Page 20 of 49 Report No. R011412646S
EN 60950-1/Am1
Clause
Requirement – Test
Result - Remark
Verdict
Max. output current (A)....................................... :
N
Current limiting method ...................................... :
N
7
CONNECTION TO CABLE DISTRIBUTION SYSTEMS
N
7.1
General
N
7.2
Protection of cable distribution system service
persons, and users of other equipment connected
to the system, from hazardous voltages in the
equipment
N
7.3
Protection of equipment users from overvoltages
on the cable distribution system
N
7.4
Insulation between primary circuits and cable
distribution systems
N
7.4.1
General
N
7.4.2
Voltage surge test
N
7.4.3
Impulse test
N
A
ANNEX A, TESTS FOR RESISTANCE TO HEAT AND FIRE
N
A.1
Flammability test for fire enclosures of movable
equipment having a total mass exceeding 18 kg,
and of stationary equipment (see 4.7.3.2)
N
A.1.1
Samples ............................................................... :
--
Wall thickness (mm)............................................. :
--
A.1.2
Conditioning of samples; temperature (C) ......... :
N
A.1.3
Mounting of samples ........................................... :
N
A.1.4
Test flame (see IEC 60695-11-3)
N
Flame A, B, C or D .............................................. :
--
A.1.5
Test procedure
N
A.1.6
Compliance criteria
N
Sample 1 burning time (s) .................................... :
--
Sample 2 burning time (s) .................................... :
--
Sample 3 burning time (s) .................................... :
--
A.2
Flammability test for fire enclosures of movable
equipment having a total mass not exceeding 18
kg, and for material and components located
inside fire enclosures (see 4.7.3.2 and 4.7.3.4)
N
A.2.1
Samples, material................................................. :
--
Wall thickness (mm)............................................. :
--
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
Page 21 of 49 Report No. R011412646S
EN 60950-1/Am1
Clause
Requirement – Test
A.2.2
Conditioning of samples; temperature (°C) ......... :
N
A.2.3
Mounting of samples ........................................... :
N
A.2.4
Test flame (see IEC 60695-11-4)
N
Flame A, B or C ................................................... :
--
A.2.5
Test procedure
N
A.2.6
Compliance criteria
N
Sample 1 burning time (s) .................................... :
--
Sample 2 burning time (s) .................................... :
--
Sample 3 burning time (s) .................................... :
--
Alternative test acc. To IEC 60695-11-5, cl. 5 and
9
N
Sample 1 burning time (s) .................................... :
--
Sample 2 burning time (s) .................................... :
--
Sample 3 burning time (s) .................................... :
--
A.3
Hot flaming oil test (see 4.6.2)
N
A.3.1
Mounting of samples
N
A.3.2
Test procedure
N
A.3.3
Compliance criterion
N
B
ANNEX B, MOTOR TESTS UNDER ABNORMAL CONDITIONS (see 4.7.2.2
and 5.3.2)
N
B.1
General requirements
N
Position ................................................................ :
--
Manufacturer ....................................................... : (see appended table 1.5.1)
--
Type .................................................................... : (see appended table 1.5.1)
--
Rated values ...................................................... : (see appended table 1.5.1)
--
B.2
Test conditions
N
B.3
Maximum temperatures
N
B.4
Running overload test
N
B.5
Locked-rotor overload test
N
Test duration (days) ............................................ :
--
Electric strength test: test voltage (V) ................. :
--
B.6
Running overload test for d.c. motors in
secondary circuits
N
B.6.1
General
N
B.6.2
Test procedure
N
A.2.7
Result - Remark
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Verdict
Shenzhen Anbotek Compliance Laboratory Limited
Page 22 of 49 Report No. R011412646S
EN 60950-1/Am1
Clause
Requirement – Test
B.6.3
Alternative test procedure
N
B.6.4
Electric strength test; test voltage (V) ................. :
N
B.7
Locked-rotor overload test for d.c. motors in
secondary circuits
N
B.7.1
General
N
B.7.2
Test procedure
N
B.7.3
Alternative test procedure
N
B.7.4
Electric strength test; test voltage (V) ................. :
N
B.8
Test for motors with capacitors
(see appended table 5.3)
N
B.9
Test for three-phase motors
(see appended table 5.3)
N
B.10
Test for series motors
N
Operating voltage (V) .......................................... :
--
ANNEX C, TRANSFORMERS (see 1.5.4 and 5.3.3)
N
Position ................................................................ :
--
Manufacturer ....................................................... : (see appended table 1.5.1)
--
Type .................................................................... : (see appended table 1.5.1)
--
Rated values ...................................................... : (see appended table 1.5.1)
--
Method of protection ............................................ :
--
C
Result - Remark
Verdict
C.1
Overload test
(see appended table 5.3)
N
C.2
Insulation
(see appended table 5.2)
N
Protection from displacement of windings ........... :
N
D
ANNEX D, MEASURING INSTRUMENTS FOR TOUCH-CURRENT TESTS
(see 5.1.4)
N
D.1
Measuring instrument
N
D.2
Alternative measuring instrument
N
E
ANNEX E, TEMPERATURE RISE OF A WINDING (see 1.4.13)
N
F
ANNEX F, MEASUREMENT OF CLEARANCES AND CREEPAGE DISTANCES
(see 2.10 and Annex G)
N
G
ANNEX G, ALTERNATIVE METHOD FOR DETERMINING MINIMUM
CLEARANCES
N
G.1
Clearances
N
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
Page 23 of 49 Report No. R011412646S
EN 60950-1/Am1
Clause
Requirement – Test
Result - Remark
G.1.1
General
N
G.1.2
Summary of the procedure for determining
minimum clearances
N
G.2
Determination of mains transient voltage (V)
N
G.2.1
AC mains supply ..................................................:
N
G.2.2
Earthed d.c. mains supplies .................................:
N
G.2.3
Unearthed d.c. mains supplies .............................:
N
G.2.4
Battery operation ................................................. :
N
G.3
Determination of telecommunication network
transient voltage (V) ............................................ :
N
G.4
Determination of required withstand voltage (V)
N
G.4.1
Mains transients and internal repetitive peaks .... :
N
G.4.2
Transients from telecommunication networks .... :
N
G.4.3
Combination of transients
N
G.4.4
Transients from cable distribution systems
N
G.5
Measurement of transient voltages (V)
N
a) Transients from a mains supply
N
For an a.c. mains supply
N
For a d.c. mains supply
N
b) Transients from a telecommunication network
N
G.6
Determination of minimum clearances ................ :
N
H
ANNEX H, IONIZING RADIATION (see 4.3.13)
N
J
ANNEX J, TABLE OF ELECTROCHEMICAL POTENTIALS (see 2.6.5.6)
N
Metal(s) used ....................................................... :
--
K
ANNEX K, THERMAL CONTROLS (see 1.5.3 and 5.3.8)
N
K.1
Making and breaking capacity
N
K.2
Thermostat reliability; operating voltage (V) ....... :
N
K.3
Thermostat endurance test; operating voltage
(V) ....................................................................... :
N
K.4
Temperature limiter endurance; operating voltage
(V) ........................................................................ :
N
K.5
Thermal cut-out reliability
N
K.6
Stability of operation
N
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Verdict
Shenzhen Anbotek Compliance Laboratory Limited
Page 24 of 49 Report No. R011412646S
EN 60950-1/Am1
Clause
Requirement – Test
Result - Remark
L
ANNEX L, NORMAL LOAD CONDITIONS FOR SOME TYPES OF
ELECTRICAL BUSINESS EQUIPMENT (see 1.2.2.1 and 4.5.2)
N
L.1
Typewriters
N
L.2
Adding machines and cash registers
N
L.3
Erasers
N
L.4
Pencil sharpeners
N
L.5
Duplicators and copy machines
N
L.6
Motor-operated files
N
L.7
Other business equipment
N
M
ANNEX M, CRITERIA FOR TELEPHONE RINGING SIGNALS (see 2.3.1)
N
M.1
Introduction
N
M.2
Method A
N
M.3
Method B
N
M.3.1
Ringing signal
N
M.3.1.1
Frequency (Hz) ................................................... :
--
M.3.1.2
Voltage (V) .......................................................... :
--
M.3.1.3
Cadence; time (s), voltage (V) ............................ :
--
M.3.1.4
Single fault current (mA) ..................................... :
--
M.3.2
Tripping device and monitoring voltage .............. :
N
M.3.2.1
Conditions for use of a tripping device or a
monitoring voltage
N
M.3.2.2
Tripping device
N
M.3.2.3
Monitoring voltage (V) ......................................... :
N
N
ANNEX N, IMPULSE TEST GENERATORS (see 1.5.7.2, 1.5.7.3, 2.10.3.9,
6.2.2.1, 7.3.2, 7.4.3 and Clause G.5)
N
N.1
ITU-T impulse test generators
N
N.2
IEC 60065 impulse test generator
N
P
ANNEX P, NORMATIVE REFERENCES
--
Q
ANNEX Q, Voltage dependent resistors (VDRs) (see 1.5.9.1)
N
a) Preferred climatic categories .......................... :
N
b) Maximum continuous voltage ......................... :
N
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Verdict
Shenzhen Anbotek Compliance Laboratory Limited
Page 25 of 49 Report No. R011412646S
EN 60950-1/Am1
Clause
Requirement – Test
Result - Remark
Verdict
c) Pulse current ................................................... :
N
R
ANNEX R, EXAMPLES OF REQUIREMENTS FOR QUALITY CONTROL
PROGRAMMES
N
R.1
Minimum separation distances for unpopulated
coated printed boards (see 2.10.6.2)
N
R.2
Reduced clearances (see 2.10.3)
N
S
ANNEX S, PROCEDURE FOR IMPULSE TESTING (see 6.2.2.3)
N
S.1
Test equipment
N
S.2
Test procedure
N
S.3
Examples of waveforms during impulse testing
N
T
ANNEX T, GUIDANCE ON PROTECTION AGAINST INGRESS OF WATER
(see 1.1.2)
N
U
ANNEX U, INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED
INSULATION (see 2.10.5.4)
N
--
V
ANNEX V, AC POWER DISTRIBUTION SYSTEMS (see 1.6.1)
N
V.1
Introduction
N
V.2
TN power distribution systems
N
W
ANNEX W, SUMMATION OF TOUCH CURRENTS
N
W.1
Touch current from electronic circuits
N
W.1.1
Floating circuits
N
W.1.2
Earthed circuits
N
W.2
Interconnection of several equipments
N
W.2.1
Isolation
N
W.2.2
Common return, isolated from earth
N
W.2.3
Common return, connected to protective earth
N
X
ANNEX X, MAXIMUM HEATING EFFECT IN TRANSFORMER TESTS
(see clause C.1)
N
X.1
Determination of maximum input current
N
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
Page 26 of 49 Report No. R011412646S
EN 60950-1/Am1
Clause
Requirement – Test
Result - Remark
X.2
Overload test procedure
Short circuit performed, see
appended table.
Y
ANNEX Y, ULTRAVIOLET LIGHT CONDITIONING TEST (see 4.3.13.3)
N
Y.1
Test apparatus .................................................... :
N
Y.2
Mounting of test samples .................................... :
N
Y.3
Carbon-arc light-exposure apparatus ................. :
N
Y.4
Xenon-arc light exposure apparatus ................... :
N
Z
ANNEX Z, OVERVOLTAGE CATEGORIES (see 2.10.3.2 and Clause G.2)
N
AA
ANNEX AA, MANDREL TEST (see 2.10.5.8)
N
BB
ANNEX BB, CHANGES IN THE SECOND EDITION
--
CC
ANNEX CC, Evaluation of integrated circuit (IC) current limiters
N
CC.1
General
N
CC.2
Test program 1 ..................................................... :
CC.3
Test program 2 ..................................................... :
N
DD
ANNEX DD, Requirements for the mounting means of rack-mounted
equipment
N
DD.1
General
N
DD.2
Mechanical strength test, variable N.................... :
N
DD.3
Mechanical strength test, 250N, including end
stops..................................................................... :
N
DD.4
Compliance .......................................................... :
N
EE
ANNEX EE, Household and home/office document/media shredders
N
EE.1
General
N
EE.2
Markings and instructions
N
Use of markings or symbols................................. :
N
Information of user instructions, maintenance
and/or servicing instructions................................. :
N
Inadvertent reactivation test ................................. :
N
EE.3
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Verdict
N
Shenzhen Anbotek Compliance Laboratory Limited
Page 27 of 49 Report No. R011412646S
EN 60950-1/Am1
Clause
Requirement – Test
EE.4
Disconnection of power to hazardous moving
parts ..................................................................... :
N
Use of markings or symbols................................. :
N
Protection against hazardous moving parts
N
Test with test finger (Figure 2A) .......................... :
N
Test with wedge probe (Figure EE1 and EE2) .... :
N
EE.5
Result - Remark
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Verdict
Shenzhen Anbotek Compliance Laboratory Limited
Page 28 of 49 Report No. R011412646S
EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2: 2013
Clause
Requirement – Test
Result - Remark
Verdict
ATTACHMENT TO TEST REPORT IEC 60950-1
EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES
Information technology equipment – Safety –
Part 1: General requirements
Differences according to.................. : EN 60950-1:2006/A11:2009/A1:2010/A12:2011/A2:2013
Attachment Form No. ....................... : EU_GD_IEC60950_1E
Master Attachment ........................... : Date 2013-09
Copyright © 2013 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.
EN 60950-1:2006/A11:2009/A1:2010/A12:2011/A2:2013 – CENELEC COMMON MODIFICATIONS
IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)
Clause
Requirement – Test
Result - Remark
Contents
Add the following annexes:
Verdict
P
Annex ZA (normative)
Normative references to international
publications with their corresponding
European publications
Annex ZB (normative)
Special national conditions
General
Delete all the “country” notes in the reference document (IEC 60950-1:2005)
according to the following list:
1.4.8 Note 2
1.5.1
Note 2 & 3
1.5.7.1 Note
1.5.8 Note 2
1.5.9.4
Note
1.7.2.1 Note 4, 5 & 6
2.2.3 Note
2.2.4
Note
2.3.2
Note
2.3.2.1 Note 2
2.3.4
Note 2
2.6.3.3 Note 2 & 3
2.7.1 Note
2.10.3.2
Note 2
2.10.5.13 Note 3
3.2.1.1 Note
3.2.4
Note 3.
2.5.1
Note 2
4.3.6 Note 1 & 2
4.7
Note 4
4.7.2.2 Note
4.7.3.1 Note 2
5.1.7.1
Note 3 & 4
5.3.7
Note 1
6
Note 2 & 5
6.1.2.1
Note 2
6.1.2.2 Note
6.2.2 Note
6.2.2.1
Note 2
6.2.2.2 Note
7.1
Note 3
7.2
Note
7.3
Note 1 & 2
G.2.1 Note 2
Annex H
Note 2
P
General
Delete all the “country” notes in the reference document (IEC 609501:2005/A1:2010) according to the following list:
P
(A1:2010)
1.3.Z1
1.5.7.1 Note
6.1.2.1
Note 2
6.2.2.1 Note 2
EE.3
Note
Add the following subclause:
1.3.Z1 Exposure to excessive sound pressure
The apparatus shall be so designed and
constructed as to present no danger when used
for its intended purpose, either in normal
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
N
Shenzhen Anbotek Compliance Laboratory Limited
Page 29 of 49 Report No. R011412646S
EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2: 2013
Clause
Requirement – Test
Result - Remark
Verdict
operating conditions or under fault conditions,
particularly providing protection against exposure
to excessive sound pressures from headphones
or earphones.
NOTE Z1 A new method of measurement is described
in EN 50332-1, Sound system equipment:
Headphones and earphones associated with portable
audio equipment - Maximum sound pressure level
measurement methodology and limit considerations Part 1: General method for “one package equipment”,
and in EN 50332-2, Sound system equipment:
Headphones and earphones associated with portable
audio equipment - Maximum sound pressure level
measurement methodology and limit considerations Part 2: Guidelines to associate sets with headphones
coming from different manufacturers.
(A12:2011)
In EN 60950-1:2006/A12:2011
N
Delete the addition of 1.3.Z1 / EN 60950-1:2006
Delete the definition of 1.2.3.Z1 / EN 609501:2006/A1:2010
1.5.1
Add the following NOTE:
N
NOTE Z1 The use of certain substances in electrical
and electronic equipment is restricted within the EU:
see Directive 2002/95/EC
1.7.2.1
(A1:2010)
1.7.2.1
(A12:2011)
In addition, for a PORTABLE SOUND SYSTEM,
the instructions shall include a warning that
excessive sound pressure from earphones and
headphones can cause hearing loss.
N
In EN 60950-1:2006/A12:2011
N
Delete NOTE Z1 and the addition for Portable
Sound System.
Add the following clause and annex to the
existing standard and amendments.
Zx Protection against excessive sound
pressure from personal music players
Zx.1 General
This sub-clause specifies requirements for
protection against excessive sound pressure
from personal music players that are closely
coupled to the ear. It also specifies requirements
for earphones and headphones intended for use
with personal music players.
A personal music player is a portable equipment
for personal use, that:
is designed to allow the user to listen to recorded
or broadcast sound or video; and primarily users
headphones or earphones that can be worn in or
on or around the ear; and allows the user to walk
around while in use.
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
N
N
Shenzhen Anbotek Compliance Laboratory Limited
Page 30 of 49 Report No. R011412646S
EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2: 2013
Clause
Requirement – Test
Result - Remark
Verdict
NOTE 1 Examples are hand-held or body-worn
portable CD players, MP3 audio players, mobile
phones with MP3 type features, PDA’s or similar
equipment.
A personal music player and earphones or
headphones intended to be used with personal
music players shall comply with the requirements
of this sub-clause.
The requirements in this sub-clause are valid for
musci or video mode only.
The requirements do not apply:
while the personal music player is connected to
an external amplifier; or
while the headphone or earphones are not used.
NOTE 2 An external amplifier is an amplifier which is
not part of the personal music player or the listening
device, but which is intended to play the music as a
standalone music player.
The requirements do not apply to:
hearing aid equipment and professional
equipment;
NOTE 3 Professional equipment is equipment sold
through special sale s channels. All products sold
through normal electronics stores are considered not to
professional equipment.
analogue personal music players (personal music
players without any kind of digital processing of
the sound signal) that are brought to the market
before the end of 2015.
NOTE 4 This exemption has been allowed because
this technology is falling out of use and it is expected
that within a few years it will no longer exist. This
exemption will not be extended to other technologies.
N
For equipment which is clearly designed or
intended for use by young children, the limits of
EN 71-1 apply.
Zx.2 Equipment requirements
No safety provision is required for equipment that
complies with the following:
equipment provided as a package (personal
music player with its listening device), where the
acoustic output LAeq,T, is ≤ 85 dBA measured
while playing the fixed “programme simulation
noise” as described in EN 50332-1; and a
personal music player provided with an analogue
electrical output socket for a listening device,
where the electrical output is ≤ 27 mV measured
as described in EN 50332-2, while playing the
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
N
Shenzhen Anbotek Compliance Laboratory Limited
Page 31 of 49 Report No. R011412646S
EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2: 2013
Clause
Requirement – Test
Result - Remark
fixed “programme simulation noise” as described
in EN 50332-1.
NOTE 1 Wherever the term acoustic acoustic output is
used in this clause, the 30 s A-weighted equipment
sound pressure level LAeq,T, is meant.
See also Zx.5 and Annex Zx.
All other equipment shall:
a) protect the user from unintentional acoustic
outputs exceeding those mentioned above; and
b) have a standard acoustic output level not
exceeding those mentioned above, and
automatically return to an output level not
exceeding those mentioned above when the
power is switched off; and
c) provide a means to actively inform the user of
the increased sound pressure when the
equipment is operated with an acoustic output
exceeding those mentioned above. Any means
used shall be acknowledged by the user before
activating a mode of operation which allows for
an acoustic output exceeding those mentioned
above. The acknowledgement does not need to
be repeated more than once every 20 h of
cumulative listening time; and
NOTE 2 Examples of means include visual or audible
signals. Action from the user is always required.
NOTE 3 The 20 h listening time is the accumulative
listening time, independent how often and how long the
personal music player has been switched off.
d) have a warning as specified in Zx.3; and
e) not exceed the following:
1) equipment provided as a package (player with
Its listening device), the acoustic output shall be ≤
100 dBA measured while playing the fixed
“programme simulation noise” described in EN
50332-1; and
2) a personal music player provided with an
analogue electrical output socket for a listening
device, the electrical output shall be ≤ 150 mV
measured as described in EN 50332-2, while
playing the fixed “programme simulation noise”
described in EN 50332-1.
For music where the average sound pressure
(long term LAeq,T) measured over the duration of
the song is lower than the average produced by
the programme simulation noise, the warning
does not need to be given as long as the average
sound pressure of the song is below the basic
limit of 85 dBA. In this case T becomes the
duration of the song.
NOTE 4 Classical music typically has an average
sound pressure (long term LAeq,T) which is much lower
than the average programme simulation noise.
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Verdict
Shenzhen Anbotek Compliance Laboratory Limited
Page 32 of 49 Report No. R011412646S
EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2: 2013
Clause
Requirement – Test
Result - Remark
Verdict
Therefore, if the player is capable to analyse the song
and compare it with the programme simulation noise,
the warning does not need to be given as long as the
average sound pressure of the song is below the basic
limit of 85 dBA.
For example, if the player is set with the programme
simulation noise to 85 dBA, but the average music level
of the song is only 65 dBA, there is no need to give a
warning or ask an acknowledgement as long as the
average sound level of the song is not above the basic
limit of 85 dBA.
Zx.3 Warning
The warning shall be placed on the equipment, or
on the packaging, or in the instruction manual
and shall consist of the following:
the symbol of Figure 1 with a minimum height of
5 mm; and the following wording, or similar:
“To prevent possible hearing damage, do not
listen at high volume levels for long periods.”
Figure 1 – Warning label (IEC 60417-6044)
Alternatively, the entire warning may be given
through the equipment display during use, when
the user is asked to acknowledge activation of
the higher level.
Zx.4 Requirements for listening devices (headphones and earphones)
Zx.4.1 Wired listening devices with analogue
input
With 94 dBA sound pressure output LAeq,T, the
input voltage of the fixed “programme simulation
noise” described in EN 50332-2 shall be ≥ 75 mV.
This requirement is applicable in any mode where
the headphones can operate (active or passive),
including any available setting (for example builtin volume level control).
N
N
N
NOTE The values of 94 dBA – 75 mV correspond with
85dBA – 27 mV and 100 dBA – 150 mV.
Zx.4.2 Wired listening devices with digital
input
With any playing device playing the fixed
“programme simulation noise” described in EN
50332-1 (and respecting the digital interface
standards, where a digital interface standard
exists that specifies the equivalent acoustic
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
N
Shenzhen Anbotek Compliance Laboratory Limited
Page 33 of 49 Report No. R011412646S
EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2: 2013
Clause
Requirement – Test
Result - Remark
Verdict
level), the acoustic output LAeq,T of the listening
device shall be ≤ 100 dBA.
This requirement is applicable in any mode where
the headphones can operate, including any
available setting (for example built-in volume
level control, additional sound feature like
equalization, etc.).
NOTE An example of a wired listening device with
digital input is a USB headphone.
Zx.4.3 Wireless listening devices
In wireless mode:
with any playing and transmitting device playing
the fixed programme simulation noise described
in EN 50332-1; and
respecting the wireless transmission standards,
where an air interface standard exists that
specifies the equivalent acoustic level; and with
volume and sound settings in the listening device
(for example built-in volume level control,
additional sound feature like equalization, etc.)
set to the combination of positions that maximize
the measured acoustic output for the
abovementioned programme simulation noise,
the acoustic output LAeq,T of the listening device
shall be ≤ 100 dBA. NOTE An example of a wireless
N
listening device is a Bluetooth headphone.
Zx.5 Measurement methods
Measurements shall be made in accordance with
EN 50332-1 or EN 50332-2 as applicable. Unless
stated otherwise, the time interval T shall be 30 s.
N
NOTE Test method for wireless equipment provided
without listening device should be defined.
2.7.1
Replace the subclause as follows:
P
Basic requirements
To protect against excessive current, shortcircuits and earth faults in PRIMARY CIRCUITS,
protective devices shall be included either as
integral parts of the equipment or as parts of the
building installation, subject to the following, a), b)
and c):
a) except as detailed in b) and c), protective
devices necessary to comply with the
requirements of 5.3 shall be included as parts of
the equipment;
b) for components in series with the mains input
to the equipment such as the supply cord,
appliance coupler, r.f.i. filter and switch, shortcircuit and earth fault protection may be provided
by protective devices in the building installation;
c) it is permitted for PLUGGABLE EQUIPMENT
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
P
Shenzhen Anbotek Compliance Laboratory Limited
Page 34 of 49 Report No. R011412646S
EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2: 2013
Clause
Requirement – Test
Result - Remark
Verdict
TYPE B or PERMANENTLY CONNECTED
EQUIPMENT, to rely on dedicated overcurrent
and short-circuit protection in the building
installation, provided that the means of
protection, e.g. fuses or circuit breakers, is fully
specified in the installation instructions.
If reliance is placed on protection in the building
installation, the installation instructions shall so
state, except that for PLUGGABLE EQUIPMENT
TYPE A the building installation shall be regarded
as providing protection in accordance with the
rating of the wall socket outlet.
2.7.2
This subclause has been declared ‘void’.
N
3.2.3
Delete the NOTE in Table 3A, and delete also in
this table the conduit sizes in parentheses.
N
3.2.5.1
Replace
N
“60245 IEC 53” by “H05 RR-F”;
“60227 IEC 52” by “H03 VV-F or
H03 VVH2-F”;
“60227 IEC 53” by “H05 VV-F or
H05 VVH2-F2”.
In Table 3B, replace the first four lines by the
following:
Up to and including 6 |
Over 6 up to and including 10| (0,75) b)
Over 10 up to and including 16| (1,0) c)
|
0,75 a) |
1,0 |
1,5
In the conditions applicable to Table 3B delete
the words “in some countries” in condition a).
In NOTE 1, applicable to Table 3B, delete the
second sentence.
3.3.4
In Table 3D, delete the fourth line: conductor
sizes for 10 to 13 A, and replace with the
following:
N
Over 10 up to and including 16 | 1,5 to 2,5 | 1,5 to
4
|
Delete the fifth line: conductor sizes for 13 to 16
A
4.3.13.6
(A1:2010)
Replace the existing NOTE by the following:
NOTE Z1 Attention is drawn to:
1999/519/EC: Council Recommendation on the
limitation of exposure of the general public to
electromagnetic fields 0 Hz to 300 GHz, and
2006/25/EC: Directive on the minimum health
and safety requirements regarding the exposure
of workers to risks arising from physical agents
(artifical optical radiation).
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
N
Shenzhen Anbotek Compliance Laboratory Limited
Page 35 of 49 Report No. R011412646S
EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2: 2013
Clause
Annex H
Requirement – Test
Result - Remark
Verdict
Standards taking into account mentioned
Recommendation and Directive which
demonstrate compliance with the applicable EU
Directive are indicated in the OJEC.
N
Replace the last paragraph of this annex by:
N
At any point 10 cm from the surface of the
OPERATOR ACCESS AREA, the dose rate shall
not exceed 1 μSv/h (0,1 mR/h) (see NOTE).
Account is taken of the background level.
Replace the notes as follows:
NOTE These values appear in Directive
96/29/Euratom.
Delete NOTE 2.
Bibliography
Additional EN standards.

ZA
NORMATIVE REFERENCES TO INTERNATIONAL PUBLICATIONS WITH
THEIR CORRESPONDING EUROPEAN PUBLICATIONS

ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause
Requirement – Test
1.2.4.1
In Denmark, certain types of Class I appliances
(see 3.2.1.1) may be provided with a plug not
establishing earthing conditions when inserted
into Danish socket-outlets.
In Norway and Sweden, for requirements see
1.7.2.1 and 7.3 of this annex.
In Finland, Norway and Sweden, resistors
bridging BASIC INSULATION in CLASS I PLUGGABLE
EQUIPMENT TYPE A must comply with the
requirements in 1.5.7.1. In addition when a single
resistor is used, the resistor must withstand the
resistor test in 1.5.7.2.
In Norway, due to the IT power system used (see
annex V, Figure V.7), capacitors are required to
be rated for the applicable line-to-line voltage
(230 V).
In Finland, Norway and Sweden, the third
dashed sentence is applicable only to equipment
as defined in 6.1.2.2 of this annex.
1.2.13.14
1.5.7.1
1.5.8
1.5.9.4
1.7.2.1
Result - Remark
In Finland, Norway and Sweden, CLASS I
PLUGGABLE EQUIPMENT TYPE A intended for
connection to other equipment or a network shall,
if safety relies on connection to protective earth
or if surge suppressors are connected between
the network terminals and accessible parts, have
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Verdict
N
N
N
N
N
N
Shenzhen Anbotek Compliance Laboratory Limited
Page 36 of 49 Report No. R011412646S
EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2: 2013
Clause
Requirement – Test
Result - Remark
a marking stating that the equipment must be
connected to an earthed mains socket-outlet.
The marking text in the applicable countries shall
be as follows:
In Finland: "Laite on liitettävä suojakoskettimilla
varustettuun pistorasiaan"
In Norway: “Apparatet må tilkoples jordet
stikkontakt”
In Sweden: “Apparaten skall anslutas till jordat
uttag”
In Norway and Sweden, the screen of the cable
distribution system is normally not earthed at the
entrance of the building and there is normally no
equipotential bonding system within the building.
Therefore the protective earthing of the building
installation need to be isolated from the screen of
a cable distribution system.
It is however accepted to provide the insulation
external to the equipment by an adapter or an
interconnection cable with galvanic isolator,
which may be provided by e.g. a retailer.
The user manual shall then have the following or
similar information in Norwegian and Swedish
language respectively, depending on in what
country the equipment is intended to be used in:
“Equipment connected to the protective earthing
of the building installation through the mains
connection or through other equipment with a
connection to protective earthing – and to a cable
distribution system using coaxial cable, may in
some circumstances create a fire hazard.
Connection to a cable distribution system has
therefore to be provided through a device
providing electrical isolation below a certain
frequency range (galvanic isolator, see EN
60728-11).”
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Verdict
Shenzhen Anbotek Compliance Laboratory Limited
Page 37 of 49 Report No. R011412646S
EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2: 2013
Clause
Requirement – Test
Result - Remark
NOTE In Norway, due to regulation for installations of
cable distribution systems, and in Sweden, a galvanic
isolator shall provide electrical insulation below 5 MHz.
The insulation shall withstand a dielectric strength of
1,5 kV r.m.s., 50 Hz or 60 Hz, for 1 min.
Verdict
N
Translation to Norwegian (the Swedish text will
also be accepted in Norway):
“Utstyr som er koplet til beskyttelsesjord via
nettplugg og/eller via annet jordtilkoplet utstyr –
og er tilkoplet et kabel-TV nett, kan forårsake
brannfare. For å unngå dette skal det ved
tilkopling av utstyret til kabel-TV nettet installeres
en galvanisk isolator mellom utstyret og kabelTV nettet.”
Translation to Swedish:
”Utrustning som är kopplad till skyddsjord via
jordat vägguttag och/eller via annan utrustning
och samtidigt är kopplad till kabel-TV nät kan i
vissa fall medfőra risk főr brand. Főr att undvika
detta skall vid anslutning av utrustningen till
kabel-TV nät galvanisk isolator finnas mellan
utrustningen och kabel-TV nätet.”
1.7.5
2.2.4
2.3.2
2.3.4
2.6.3.3
2.7.1
In Denmark, socket-outlets for providing power to
other equipment shall be in accordance with the
Heavy Current Regulations, Section 107-2-D1,
Standard Sheet DK 1-3a, DK 1-5a or DK 1-7a,
when used on Class I equipment. For
STATIONARY EQUIPMENT the socket-outlet
shall be in accordance with Standard Sheet DK
1-1b or DK 1-5a.
For CLASS II EQUIPMENT the socket outlet shall be
in accordance with Standard Sheet DKA 1-4a.
In Norway, for requirements see 1.7.2.1, 6.1.2.1
and 6.1.2.2 of this annex.
In Finland, Norway and Sweden there are
additional requirements for the insulation. See
6.1.2.1 and 6.1.2.2 of this annex.
In Norway, for requirements see 1.7.2.1, 6.1.2.1
and 6.1.2.2 of this annex.
In the United Kingdom, the current rating of the
circuit shall be taken as 13 A, not 16 A.
In the United Kingdom, to protect against
excessive currents and short-circuits in the
PRIMARY CIRCUIT of DIRECT PLUG-IN
EQUIPMENT, tests according to 5.3 shall be
conducted, using an external protective device
rated 30 A or 32 A. If these tests fail, suitable
protective devices shall be included as integral
parts of the DIRECT PLUG-IN EQUIPMENT, so
that the requirements of 5.3 are met.
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
N
N
N
N
P
N
Shenzhen Anbotek Compliance Laboratory Limited
Page 38 of 49 Report No. R011412646S
EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2: 2013
Clause
Requirement – Test
Result - Remark
Verdict
2.10.5.13
In Finland, Norway and Sweden, there are
additional requirements for the insulation, see
6.1.2.1 and 6.1.2.2 of this annex.
N
3.2.1.1
In Switzerland, supply cords of equipment
having a RATED CURRENT not exceeding 10 A
shall be provided with a plug complying with SEV
1011 or IEC 60884-1 and one of the following
dimension sheets:
N
SEV 6532-2.1991
Plug Type 15
3P+N+PE 250/400 V, 10 A
SEV 6533-2.1991
Plug Type 11
L+N
250 V, 10 A
SEV 6534-2.1991
L+N+PE
Plug Type 12
250 V, 10 A
In general, EN 60309 applies for plugs for
currents exceeding 10 A. However, a 16 A plug
and socket-outlet system is being introduced in
Switzerland, the plugs of which are according to
the following dimension sheets, published in
February 1998:
SEV 5932-2.1998: Plug Type 25 ,
3L+N+PE 230/400 V, 16 A
SEV 5933-2.1998:Plug Type 21,
L+N,
250 V, 16A
SEV 5934-2.1998: Plug Type 23,
L+N+PE
3.2.1.1
250 V, 16 A
In Denmark, supply cords of single-phase
equipment having a rated current not
exceeding13 A shall be provided with a plug
according to the Heavy Current Regulations,
Section 107-2-D1.
CLASS I EQUIPMENT provided with socketoutlets with earth contacts or which are intended
to be used in locations where protection against
indirect contact is required according to the wiring
rules shall be provided with a plug in accordance
with standard sheet DK 2-1a or DK 2-5a.
If poly-phase equipment and single-phase
equipment having a RATED CURRENT
exceeding 13 A is provided with a supply cord
with a plug, this plug shall be in accordance with
the Heavy Current Regulations, Section 107-2-D1
or EN 60309-2.
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
N
Shenzhen Anbotek Compliance Laboratory Limited
Page 39 of 49 Report No. R011412646S
EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2: 2013
Clause
Requirement – Test
3.2.1.1
In Spain, supply cords of single-phase equipment
having a rated current not exceeding 10 A shall
be provided with a plug according to UNE
20315:1994.
Result - Remark
Verdict
N
Supply cords of single-phase equipment having a
rated current not exceeding 2,5 A shall be
provided with a plug according to UNE-EN
50075:1993.
CLASS I EQUIPMENT provided with socketoutlets with earth contacts or which are intended
to be used in locations where protection against
indirect contact is required according to the wiring
rules, shall be provided with a plug in accordance
with standard UNE 20315:1994.
If poly-phase equipment is provided with a supply
cord with a plug, this plug shall be in accordance
with UNE-EN 60309-2.
3.2.1.1
In the United Kingdom, apparatus which is fitted
with a flexible cable or cord and is designed to be
connected to a mains socket conforming to BS
1363 by means of that flexible cable or cord and
plug, shall be fitted with a ‘standard plug’ in
accordance with Statutory Instrument 1768:1994
- The Plugs and Sockets etc. (Safety)
Regulations 1994, unless exempted by those
regulations.
N
NOTE ‘Standard plug’ is defined in SI 1768:1994 and
essentially means an approved plug conforming to BS
1363 or an approved conversion plug.
3.2.1.1
In Ireland, apparatus which is fitted with a flexible
cable or cord and is designed to be connected to
a mains socket conforming to I.S. 411 by means
of that flexible cable or cord and plug, shall be
fitted with a 13 A plug in accordance with
Statutory Instrument 525:1997 - National
Standards Authority of Ireland (section 28) (13 A
Plugs and Conversion Adaptors for Domestic
Use) Regulations 1997.
N
3.2.4
In Switzerland, for requirements see 3.2.1.1 of
this annex.
N
3.2.5.1
In the United Kingdom, a power supply cord
with conductor of 1,25 mm2 is allowed for
equipment with a rated current over 10 A and up
to and including 13 A.
N
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
Page 40 of 49 Report No. R011412646S
EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2: 2013
Clause
Requirement – Test
3.3.4
In the United Kingdom, the range of conductor
sizes of flexible cords to be accepted by terminals
for equipment with a RATED CURRENT of over
10 A up to and including 13 A is:
Result - Remark
Verdict
N
• 1,25 mm2 to 1,5 mm2 nominal cross-sectional
area.
4.3.6
In the United Kingdom, the torque test is
performed using a socket outlet complying with
BS 1363 part 1:1995, including Amendment
1:1997 and Amendment 2:2003 and the plug part
of DIRECT PLUG-IN EQUIPMENT shall be
assessed to BS 1363: Part 1, 12.1, 12.2, 12.3,
12.9, 12.11, 12.12, 12.13, 12.16 and 12.17,
except that the test of 12.17 is performed at not
less than 125 °C. Where the metal earth pin is
replaced by an Insulated Shutter Opening Device
(ISOD), the requirements of clauses 22.2 and 23
also apply.
N
4.3.6
In Ireland, DIRECT PLUG-IN EQUIPMENT is
known as plug similar devices. Such devices
shall comply with Statutory Instrument 526:1997 National Standards Authority of Ireland (Section
28) (Electrical plugs, plug similar devices and
sockets for domestic use) Regulations, 1997.
N
5.1.7.1
In Finland, Norway and Sweden TOUCH
CURRENT measurement results exceeding 3,5
mA r.m.s. are permitted only for the following
equipment:
N
• STATIONARY PLUGGABLE EQUIPMENT
TYPE A that
is intended to be used in a
RESTRICTED ACCESS LOCATION where
equipotential bonding has been applied, for
example, in a telecommunication centre; and
has provision for a permanently connected
PROTECTIVE EARTHING CONDUCTOR; and
is provided with instructions for the installation of
that conductor by a SERVICE PERSON;
• STATIONARY PLUGGABLE EQUIPMENT
TYPE B;
• STATIONARY PERMANENTLY CONNECTED
EQUIPMENT.
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
Page 41 of 49 Report No. R011412646S
EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2: 2013
Clause
Requirement – Test
6.1.2.1
In Finland, Norway and Sweden, add the
following text between the first and second
paragraph of the compliance clause:
(A1:2010)
Result - Remark
Verdict
N
If this insulation is solid, including insulation
forming part of a component, it shall at least
consist of either
- two layers of thin sheet material, each of which
shall pass the electric strength test below, or
- one layer having a distance through insulation
of at least 0,4 mm, which shall pass the electric
strength test below.
Alternatively for components, there is no distance
through insulation requirements for the insulation
consisting of an insulating compound completely
filling the casing, so that CLEARANCES and
CREEPAGE DISTANCES do not exist, if the
component passes the electric strength test in
accordance with the compliance clause below
and in addition
- passes the tests and inspection criteria of
2.10.11 with an electric strength test of 1,5 kV
multiplied by 1,6 (the electric strength test of
2.10.10 shall be performed using 1,5 kV), and
- is subject to ROUTINE TESTING for electric
strength during manufacturing, using a test
voltage of 1,5 kV.
It is permitted to bridge this insulation with an
optocoupler complying with 2.10.5.4 b).
It is permitted to bridge this insulation with a
capacitor complying with EN 60384-14:2005,
subclass Y2.
A capacitor classified Y3 according to
EN 60384-14:2005, may bridge this insulation
under the following conditions:
- the insulation requirements are satisfied by
having a capacitor classified Y3 as defined by
EN 60384-14, which in addition to the Y3 testing,
is tested with an impulse test of 2,5 kV defined in
EN 60950-1:2006, 6.2.2.1;
- the additional testing shall be performed on all
the test specimens as described in EN 60384-14;
- the impulse test of 2,5 kV is to be performed
before the endurance test in EN 60384-14, in the
sequence of tests as described in EN 60384-14.
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
N
Shenzhen Anbotek Compliance Laboratory Limited
Page 42 of 49 Report No. R011412646S
EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2: 2013
Clause
Requirement – Test
Result - Remark
6.1.2.2
In Finland, Norway and Sweden, the exclusions
are applicable for PERMANENTLY
CONNECTED EQUIPMENT, PLUGGABLE
EQUIPMENT TYPE B and equipment intended to
be used in a RESTRICTED ACCESS LOCATION
where equipotential bonding has been applied,
e.g. in a telecommunication centre, and which
has provision for a permanently connected
PROTECTIVE EARTHING CONDUCTOR and is
provided with instructions for the installation of
that conductor by a SERVICE PERSON.
N
7.2
In Finland, Norway and Sweden, for
requirements see 6.1.2.1 and 6.1.2.2 of this
annex.
The term TELECOMMUNICATION NETWORK in
6.1.2 being replaced by the term CABLE
DISTRIBUTION SYSTEM.
N
7.3
In Norway and Sweden, for requirements see
1.2.13.14 and 1.7.2.1 of this annex.
N
7.3
In Norway, for installation conditions see EN
60728-11:2005.
N
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Verdict
Shenzhen Anbotek Compliance Laboratory Limited
Page 43 of 49 Report No. R011412646S
Tables
1.5.1
TABLE: List of critical components
Object/part
No.
Manufacturer/
trademark
Type/model
Technical data
Standard
(Edition / year)
XH-101 94V-0
130℃
FR-4
1.2mm
Various
PCB
P
Mark(s) of
conformity1)
--
--
1) An asterisk indicates a mark which assures the agreed level of surveillance.
1.6.2
TABLE: electrical data test (in normal conditions)
P
fuse #
I rated (A)
U (V)
P (W)
I (A)
Ifuse (A)
--
--
5.0
--
--
--
condition
--
Remark:
2.1.1.5 c) 1) TABLE: max. V, A, VA test
N
Voltage (rated)
(V)
Current (rated)
(A)
Voltage (max.)
(V)
Current (max.)
(A)
VA (max.)
(VA)
--
--
--
--
--
Remark: Built-in equipment, consider in system
2.1.1.5 c) 2) TABLE: stored energy
N
Capacitance C (µF)
Voltage U (V)
Energy E (J)
--
--
--
Remark:
2.5
TABLE: limited power source measurement
N
Condition
Output voltage (Uoc) (V)
Output current (Isc) (A)
Apparent power (S) (VA)
Normal condition
--
--
--
Isc (A)
VA
Single fault
--
Meas.
Limit
Meas.
Limit
--
--
--
--
Remark: SC=Short circuit, OC=Open circuit
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
Page 44 of 49 Report No. R011412646S
Tables
2.10.2
TABLE: Working voltage measurement
Component
From
--
--
To
--
N
V peak
V rms
Remark
--
--
--
Remark:
2.10.3 and
2.10.4
TABLE: Clearance and creepage distance measurements
Clearance (cl) and creepage
distance (cr) at/of/between:
N
U peak
(V)
U r.m.s.
(V)
Required cl
(mm)
cl
(mm)
Required cr
(mm)
cr
(mm)
--
--
--
--
--
--
--
Supplementary information:
1) Max. operating altitude up to 2000m above sea level, and the correction factor of Cl. is 1.00
2) Thickness of the teflon tube used inside T1, is no less than 0.4mm.
2.10.5
TABLE: Distance through insulation measurements
distance through insulation di at/of:
N
U peak
(V)
U rms (V)
Test voltage
(V)
Required DTI
(mm)
DTI
(mm)
--
--
--
--
--
-Remark:
4.3.8
TABLE: Batteries
N
The tests of 4.3.8 are applicable only when appropriate battery
data is not available
N
Is it possible to install the battery in a reverse polarity position?
N
Non-rechargeable batteries
Discharging
Rechargeable batteries
Meas.
current
Manuf.
Specs.
Unintentional
charging
Charging
Discharging
Max.
current
during
normal
condition
--
--
--
--
--
--
--
Meas.
Manuf.
current
Specs.
-----
Max.
current
during fault
condition
--
--
---
--
--
--
--
---
Meas.
current
Manuf.
Specs.
Meas.
current
Manuf.
Specs.
Reversed charging
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
---
Shenzhen Anbotek Compliance Laboratory Limited
Page 45 of 49 Report No. R011412646S
Tables
Test results:
See below
Verdict
- Chemical leaks
No leakaged
N
- Explosion of the battery
No explosion
N
- Emission of flame or expulsion of molten metal
No fire
N
- Electric strength tests of equipment after completion of tests
No damaged
N
Supplementary information:
4.5
TABLE: Thermal requirements
P
Supply voltage (V) .......................... :
5VDC
--

Ambient Tmin (C) ............................ :
40.0
--

Ambient Tmax (C) ............................ :
40.0
--

(Normal operation)
--
Allowed
Tmax (C)
PCB
45.5
--
130
Enclosure outside
43.3
--
95
PCB near IC
47.6
--
130
Maximum measured temperature T of part/at:
4.5.5
TABLE: Ball pressure test of thermoplastics
N
 2 mm
required impression diameter (mm) ....................... :
part
---
test temperature (C) impression diameter
(mm)
--
--
--
Remark:
4.7
TABLE: Resistance to fire
Part
Manufacturer of
material
P
Type of material
Thickness Flammability
(mm)
class
Evidence
Refer to table 1.5.1 for details
Supplementary information:
5.1.6
Condition
--
TABLE: Touch current measurement
N
terminal A (mA)
terminal A (mA)
Limit (mA)
--
--
--
Comments
--
Input:
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
Page 46 of 49 Report No. R011412646S
Tables
5.2
TABLE: Electric strength tests, impulse tests and voltage surge tests
Test voltage applied between:
Voltage shape Test voltage
(AC, DC,
(V)
impulse, surge)
Input to enclosure
DC
500V
P
Breakdown
Yes / No
No
Supplementary information:
5.3.5
No.
TABLE: Fault condition tests
ambient temperature (C)..............................................:
25℃
--
model/type of power supply ..........................................:
See page 1
--
manufacturer of power supply ......................................:
See page 1
--
rated markings of power supply ....................................:
See rating label
--
Component Fault
No.
1
P
--
--
Test Test
voltage time
(V)
--
--
Fuse Fuse
#.
current
(A)
---
--
Result
--
Remark:
The Hi-pot test conducted successfully after the completion of the fault condition.
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
Page 47 of 49 Report No. R011412646S
Photos
Photo 1
[√ ] front
[
] rear
[
] right side
[
] left side
[
] top
[
] bottom
[
] internal
Photo 2
[√ ] front
[
] rear
[
] right side
[
] left side
[
] top
[
] bottom
[
] internal
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
Page 48 of 49 Report No. R011412646S
Photos
Photo 3
[
] front
[√ ] rear
[
] right side
[
] left side
[
] top
[
] bottom
[
] internal
Photo 4
[
] front
[
] rear
[
] right side
[
] left side
[
] top
[√ ] bottom
[
] internal
Shenzhen Anbotek Compliance Laboratory Limited
Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
Shenzhen Anbotek Compliance Laboratory Limited
Page 49 of 49 Report No. R011412646S
Photos
Photo 5
[√ ] front
[
] rear
[
] right side
[
] left side
[√ ] top
[
] bottom
[
] internal
Photo 6
[√ ] front
[
] rear
[√ ] right side
[
] left side
[
] top
[
] bottom
[
] internal
Shenzhen Anbotek Compliance Laboratory Limited