Viva 250SP triton-blue

 PROFESSIONAL SCANNER USER’S MANUAL
VIVA 250S
KEEP THIS MANUAL FOR FUTURE NEEDS
For your own safety, please read this user manual carefully before installing the device.
Every person involved with the installation, operation and maintenance of this device
has to:
-be qualified
-follow carefully the instructions of this manual
INTRODUCTION:
Thank you for having chosen this professional moving head.
You will see you have acquired a powerful and versatile device.
Unpack the device. Inside the box you should find: the fixture device, a power cable, an
XLR connection cable, a safety cable and this manual. Please check carefully that there is no
damage caused by transportation. Should there be any, consult your dealer and don’t install this
device.
Features
·Philips MSD250/2,8500K base: GY 9.5
·8 standard DMX-512 channels.
·Operation mode: DMX controller, stand alone, sound activated, master slave.
·Pan: 156° movement, Tilt: 45° movement.
·Colours: 9 colours plus white, with rainbow effect.
·Gobos: 7 rotating gobos plus open, with different speed gobo shaking.
·Strobe: 0~10 flashes per second, or random strobe.
·Display: 4-digit display.
·Editable program: Program via control panel or external DMX controller. Up to 48
scenes can be saved into units EEPROM, then can be run by stand alone function.
-2-
XM044 V1.8-NR
SAFETY INSTRUCTIONS
This device has left the factory in perfect condition. In order to maintain this condition
and to ensure a safe operation, it is absolutely necessary for the user to follow the
safety instructions and warning notes written in this user manual.
If the device has been exposed to temperature changes due to environmental changes,
do not switch it on immediately. The arising condensation could damage the device.
Leave the device switched off until it has reached room temperature.
This device falls under protection-class I. Therefore it is essential that the device be
earthed.
The electric connection must carry out by qualified person.
Make sure that the available voltage is not higher than stated at the end of this manual.
Make sure the power cord is never crimped or damaged by sharp edges. If this would
be the case, replacement of the cable must be done by an authorized dealer.
Always disconnect from the mains, when the device is not in use or before cleaning it.
Only handle the power cord by the plug. Never pull out the plug by tugging the power
cord.
During initial start-up some smoke or smell may arise. This is a normal process and
does not necessarily mean that the device is defective, it should decrease gradually.
-3-
XM044 V1.8-NR
Please be aware that damages caused by manual modifications to the device are not
subject to warranty. Keep away from children and non-professionals.
GENERAL GUIDELINES
This device is a lighting effect for professional use on stages, in discotheques, theatres,
etc.
This fixture is only allowed to be operated with the max alternating current which
stated in the technical specifications in the last page of this manual, the device was
designed for indoor use only.
Lighting effects are not designed for permanent operation. Consistent operation breaks
may ensure that the device will serve you for a long time without defects. Do not shake
the device.
Avoid brute force when installing or operating the device.
While choosing the installation-spot, please make sure that the device is not exposed
to extreme heat, moisture or dust. The minimum distance between light-output from the
projector and the illuminated surface must be more than 0,5 meter.
Operate the device only after having familiarized with its functions. Do not permit
operation by persons not qualified for operating the device. Most damages are the
result of unprofessional operation.
Please use the original packaging if the device is to be transported.
For safety reasons, please be aware that all modifications on the device are forbidden.
-4-
XM044 V1.8-NR
If this device will be operated in any way different to the one described in this manual,
the product may suffer damages and the guarantee becomes void. Furthermore, any
other operation may lead to short-circuit, burns, electric shock, lamp explosion, crash,
etc.
INSTALLATION INSTRUCTIONS
a) Installing or replacing the lamp
Before replacing the lamp let the lamp cool down, because during operation, the lamp
can reach very high temperature.
During the installation of halogen lamps do not touch the glass bulbs bare handed.
Always use a cloth to handle the lamps during insertion and removal.
Do not install lamps with a higher wattage. They generate higher temperatures than
which the device was designed for.
For the installation, you need one: MSD250/2 GY9.5 lamp;
Procedure:
1) Unscrew the 2 screws on the back of the housing, holding the plate where the lamp
is underneath.
2) Gently pull the socket holder using the knob in the middle.
3) Carefully insert the lamp into the socket. Please remember there is only one way to
insert the lamp. Gently slide the lamp and its lamp holder back into place and fasten
the 2 screws.
4) On the access plate there are 3 small screws marked 1, 2 and 3.which are used to
adjust the lamp holder in the lamp housing. You can adjust the 3 screws to fine-turn
the position of the lamp to get the maximum light output as shown below.
-5-
XM044 V1.8-NR
Please remember the lamp is not a hot-restrike type, you must wait for approximately
10
minutes after having turned off the lamp before you can turn it back on again.
b) Mounting the device
The installation of the effect has to be built and constructed in a way that it can hold 10
times the weight for 1 hour without any harming deformation.
The installation must always be secured with a secondary safety attachment, e.g. an
appropriate safety cable.
Never stand directly below the device when mounting, removing or servicing the
fixture.
The operator has to make sure the safety relating and machine technical installations
are approved by an expert before taking the device into operation for the first time.
These installations have to be approved by a skilled person once a year.
Cautions:
-6-
XM044 V1.8-NR
The effect should be installed outside areas where persons may reach it, walk by or be
seated.
Overhead mounting requires extensive experience, including amongst others
calculating working load limits, installation material being used, and periodic safety
inspection of all installation material and the device. If you lack these qualifications, do
not attempt the installation yourself. Improper installation can result in bodily injury.
Before mounting make sure that the installation area can hold a minimum point load of
10 times the device’s weight.
Connect the fixture to the mains with the power plug.
Installation via the Omega holders
Screw one clamp each via a M10 screw and nut directly into the bracket of the scanner. Pull the
safety-chain through the bracket of the base and over the trussing system or a safe fixation spot.
DMX-512 control connection
Connect the provided XLR cable to the female 3-pin XLR output of your controller and
the other side to the male 3-pin XLR input of the moving head. You can chain multiple
-7-
XM044 V1.8-NR
Moving head together through serial linking. The cable needed should be two core,
screened cable with XLR input and output connectors. Please refer to the diagram
below.
DMX-512 connection with DMX terminator
For installations where the DMX cable has to run a long distance or is in an electrically
noisy environment, such as in a discotheque, it is recommended to use a DMX
terminator. This helps in preventing corruption of the digital control signal by electrical
noise. The DMX terminator is simply an XLR plug with a 120 Ω resistor connected
between pins 2 and 3,which is then plugged into the output XLR socket of the last
fixture in the chain. Please see illustrations below.
Address 1
Address 9
Address 17
Projector DMX start address selection
All fixtures should be given a DMX starting address when using a DMX signal, so that
the correct fixture responds to the correct control signals. This digital starting address
is the channel number from which the fixture starts to “listen” to the digital control
information sent out from the DMX controller. The allocation of this starting address is
achieved by setting the correct number on the display located on the base of the
device.
You can set the same starting address for all fixtures or a group of fixtures, or make
-8-
XM044 V1.8-NR
different address for each fixture individually.
If you set the same address, all the units will start to “listen” to the same control signal
from the same channel number. In other words, changing the settings of one channel
will affect all the fixtures simultaneously.
If you set a different address, each unit will start to “listen” to the channel number you
have set, based on the quantity of control channels of the unit. That means changing
the settings of one channel will affect only the selected fixture.
In the case of the scanner, which is 8 channel fixture, you should set the starting
address of the first unit to 1, the second unit to 9 (8 + 1), the third to 17 (9 + 8), and so
on.
Note:
The modes of DMX 512 data and lamp are shown via the display:
1. After switching on, the device will automatically detect whether DMX 512 data is received or not.
If the data is received, the display will show "A.001" with the actually set address. If there is no data
received at the DMX-input, the display will flash "A001" with the actually set address.
This situation can occur if:
- The 3 PIN XLR plug (cable with DMX signal from controller) is not connected with the input of the
device.
- The controller is switched off or defective, if the cable or connector is defective or the signal wires
are swap in the input connector.
It’s necessary to insert the XLR termination plug (with 120 Ohm) in the last lighting in the link in
order to ensure proper transmission on the DMX data link.
2. If the lamp is on, the display will show "A00.1" with the actually set address. If the lamp is off, the
display will show "A001" with the actually set address.
Control Board
The Control Board offers several features: you can simply set the starting address, switch on and
off the lamp, run the pre-programmed program or make a reset.
The main menu is accessed by pressing the Mode/esc-button until the display starts flashing.
Browse through the menu by pressing the Up-button or Down-button. Press the Enter-button in
order to select the desired menu. You can change the selection by pressing the Up-button or
Down-button. Confirm every selection by pressing the Enter-button. You can leave every mode by
pressing the Mode/esc-button. The functions provided are described in the following sections.
Default settings shaded.
-9-
XM044 V1.8-NR
Main
menu
Sub.
menu
ADDR
Extension
VALU
SLAV
(AU-A)
MAST
(AU-M)
ALON
(SO-A)
MAST
(SO-M)
VALU
D–XX
D-00 (DXXX)
RDIS
ON/OFF
CLDI
ON/OFF
ON/OFF
M-XX
ON/OFF
ON/OFF
ON/OFF
RUN
MODE
SOUN
DISP
1
2
SET
RPAN
RTIL
MIC
AUTO
SOUN
REST
LODA
4
ON/OFF
VER
LADJ
V-1.0~V-9.9
ON/OFF
TEST
T–01~T–30
ADJU
CODE
CXXX
XXXX(-128~127)
MATI
LATI
CLMT
CLLT
CH01~CH30
0000~9999(hours)
0000~9999(hours)
ON/OFF
ON/OFF
STEP
S–01 ~S–48
REC.
RE.XX
WHEL
3
A001~AXXX (AXXX)
ON/OFF
(SLAV)
ALON
AUTO
0
Display
TIME
EDIT
SC01
~SC48
Function
DMX address setting
Slave setting
Automatic Run in Stand
Alone
Automatic Run as Master
Sound-controlled Run in
Stand Alone
Sound-controlled Run as
Master
Display the DMX 512 value
of each channel
Reverse display
Shut off LED display
Pan Reverse
Tilt Reverse
Mic sensitivity
Automatic Run by no DMX
Sound Run by no DMX
Reset
Restore factory settings
Software version
Lamp adjustment
Test function of each
channel
Fixture code *code is
“C050”
Motor Calibration
Fixture running time
Lamp running time
Clear fixture time
Clear lamp time
Steps of Program Run
C–01~C–30
0 1 XX(00~FFH)
3 0 XX(00~FFH)
Auto Save Scene
Edit the channels of each
scene
TIME
TXXX(001~999)
Time for each scene
CNIN
ON/OFF
Edit program via controller
- 10 -
XM044 V1.8-NR
Main functions
- Main menu 0
1. Press [MODE/ESC] to enter the main menu "MODE" (display flashing)
2. Press [ENTER] and select "ADDR", “RUN” or "DISP" by pressing [UP] or [DOWN] button.
3. Press [ENTER] for selecting the desired sub menu.
- DMX address setting, Slave setting
- DMX address setting
With this function, you can adjust the desired DMX-address via the Control Board.
1. Select “VALU” by pressing [UP] or [DOWN] button.
2. Press [ENTER], adjust the DMX address by pressing [UP] or [DOWN] button.
3. Press [ENTER] to confirm or pressing [MODE/ESC] to return to main menu.
- Slave setting
With this function, you can define the device as slave.
1. Select “SLAV” by pressing [UP] or [DOWN] button.
2. Press [ENTER], the display shows “ON” or “OFF”.
3. Press [UP] to select “ON” if you wish to enable this function or press [DOWN] to select “OFF” if
you don’t.
4. Press [ENTER] to confirm or press [MODE/ESC] to return to main menu.
- Program Run, Master setting
With the function "RUN", you can run the internal program. You can set the number of steps under
Step. You can edit the individual scenes under Edit. You can run the individual scenes either
automatically (AUTO), i.e. with the adjusted Step-Time or sound-controlled (SOUN). The selection
"ALON" means Stand Alone-mode and "MAST" that the device is defined as master.
- 11 -
XM044 V1.8-NR
1.
2.
3.
4.
Select "AUTO" or "SOUN" by pressing [UP] or [DOWN] button.
Press [ENTER] for selecting the desired extension menu.
Select "ALON" or "MAST" by pressing [UP] or [DOWN] button.
Press [ENTER] to confirm or Press [MODE/ESC] to return to the main menu.
- Display the DMX-value, Reverse display, Shut off LED display
- Display the DMX 512 value of each channel
With this function you can display the DMX 512 value of each channel.
1. Select "VALU" by pressing [UP] or [DOWN] button.
2. Press [ENTER] to confirm; the display shows“D-00”. In this setting, the DMX-adjustment of
every channel will be displayed.
3. Press [UP] or [DOWN] button in order to select the desired channel. If you select “D-14” the
display will only show the DMX-value of the 14th channel.
4. Press [ENTER] to confirm or Press [MODE/ESC] to return to the main menu.
5. The display shows "D- XX”, “X” stands for the DMX-value of the selected channel.
- Reverse display
With this function you can rotate the display by 180°.
1. Select "RDIS" by pressing [UP] or [DOWN] button.
2. Press [ENTER], the display shows “ON” or “OFF”.
3. Press [UP] to select “ON” if you wish to enable this function or press [DOWN] button to “OFF” if
you don’t; the display will rotate by 180°.
4. Press [ENTER] to confirm or Press [MODE/ESC] to return to the main menu.
- Shut off LED display
With this function you can shut off the LED display after 2 minutes.
1. Select "CLDI" by pressing [UP] or [DOWN] button.
2. Press [ENTER], the display shows “ON” or “OFF”.
3. Press [UP] to select “ON” if you wish to enable this function or press [DOWN] button to “OFF” if
you don’t.
4. Press [ENTER] to confirm or Press [MODE/ESC] to return to the main menu.
- Main menu 2
1. Press [MODE/ESC] to enter the main menu (display flashing).
2. Press [UP] or [DOWN] button. To select “SET”.
- Pan Reverse
- 12 -
XM044 V1.8-NR
With this function you can reverse the Pan-movement.
1. Select “RPAN” by pressing [UP] or [DOWN] button.
2. Press [ENTER], the display shows “ON” or “OFF”.
3. Press [UP] to select “ON” if you wish to enable this function or press [DOWN] button to “OFF” if
you don’t.
4. Press [ENTER] to confirm or Press [MODE/ESC] to return to the main menu.
- Tilt Reverse
With this function you can reverse the Tilt-movement.
1. Select “RTIL” by pressing [UP] or [DOWN] button.
2. Press [ENTER], the display shows “ON” or “OFF”.
3. Press [UP] to select “ON” if you wish to enable this function or press [DOWN] button to “OFF” if
you don’t.
4. Press [ENTER] to confirm or Press [MODE/ESC] to return to the main menu.
-Mic sensitivity
With this function you can adjust the sensitivity of the microphone.
1. Select “MIC” by pressing [UP] or [DOWN] button.
2. Press [ENTER], the display shows “M-XX”, “XX” stands for the number from 0 to 99.
3.. Press [ENTER] to confirm or Press [MODE/ESC] to return to the main menu.
-Automatic Run by no DMX
With this function you can automatic run the device by no DMX.
1. Select “AUTO” by pressing [UP] or [DOWN] button.
2. Press [ENTER], the display shows “ON” or “OFF”.
3. Press [UP] to select “ON” if you wish to enable this function or “OFF” if you don’t.
4. Press [ENTER] to confirm or Press [MODE/ESC] to return to the main menu.
-Sound Run by no DMX
With this function you can sound run the device by no DMX.
1. Select “SOUN” by pressing [UP] or [DOWN] button.
2. Press [ENTER], the display shows “ON” or “OFF”.
3. Press [UP] to select “ON” if you wish to enable this function or “OFF” if you don’t.
4. Press [ENTER] to confirm or Press [MODE/ESC] to return to the main menu.
- Reset
With this function you can reset the device via the Control Board.
1. Select “REST” by pressing [UP] or [DOWN] button.
2. Press [ENTER], the display shows “ON” or “OFF”.
3. Press [UP] to select “ON” if you wish to enable this function or “OFF” if you don’t.
4. Press [ENTER] to confirm or Press [MODE/ESC] to return to the main menu.
- Restore factory settings
With this function you can restore the factory settings of the device. All settings will be set back to
the default values (shaded). Any edited scenes will be lost.
1. Select “LODA” by pressing [UP] or [DOWN] button.
2. Press [ENTER], the display shows “ON” or “OFF”.
3. Press [UP] to select “ON” if you wish to enable this function or press [DOWN] button to “OFF” if
you don’t.
4. Press [ENTER] to confirm or Press [MODE/ESC] to return to the main menu.
- 13 -
XM044 V1.8-NR
- Software version
With this function you can display the software version of the device.
1. Select “VER” by pressing [UP] or [DOWN] button.
2. Press [ENTER], the display shows “V-X.X”, “X.X” stands for the version number, e.g. “V-1.0”,
“V-2.6”.
3. Press [MODE/ESC] to return to the main menu.
- Main menu 3
1. Press [MODE/ESC] to enter the main menu (display flashing).
2. Press [UP] or [DOWN] button to select “ADJU”.
- Lamp adjustment
With this function you can adjust the lamp via the Control Board. The shutter opens and the lamp
can be adjusted. In this mode, the device will not react to any control signal.
1. Select “LADJ” by pressing [UP] or [DOWN] button.
2. Press [ENTER], the display shows “ON” or “OFF”.
3. Press [UP] to select “ON” if you wish to enable this function or press [DOWN] button to “OFF” if
you don’t.
4. Press [ENTER] to confirm or Press [MODE/ESC] to return to the main menu.
- Test function of each channel
With this function you can test channel on its (correct) function.
1.
2.
3.
4.
5.
Select “TEST” by pressing [UP] button.
Press [ENTER], the display shows “T-XX”, “X” stands for the channel number.
The current channel will be tested.
Select the desired channel by pressing [UP] or [DOWN] button.
Press [ENTER] to confirm or Press [MODE/ESC] to return to the main menu.
1.
2.
4.
5.
- Fixture code and motor fix
Select “WHEL” by pressing [UP] or [DOWN] button.
Press [ENTER], the display shows “CODE” or “CH01-CH30”.
Select “CODE” or “CH01-CH30” by pressing [UP] or [DOWN] button.
Press [ENTER] to confirm or Press [MODE/ESC] to return to the main menu.
- Main menu 4
- 14 -
XM044 V1.8-NR
1. Press [MODE/ESC] to enter the main menu (display flashing).
2. Press [UP] or [DOWN] button to select “TIME”.
- Fixture running time
With this function you can display the running time of the device.
1. Select “MATI” by pressing [UP] or [DOWN] button.
2. Press [ENTER], the display shows “XXXX”, “X” stands for the number of hours.
3. Press [ENTER] to confirm or Press [MODE/ESC] to return to the main menu.
- Lamp running time
With this function you can display the running time of the lamp.
1. Select “LATI” by pressing [UP] button.
2. Press [ENTER], the display shows “XXXX”, “X” stands for the number of hours.
3. Press [MODE/ESC] to return to the main menu.
- Clear fixture time
With this function you can clear the running time of the device.
1. Select “CLMT” by pressing [UP] or [DOWN] button.
2. Press [ENTER], the display shows “ON” or “OFF”.
3. Press [UP] to select “ON” if you wish to enable this function or press [DOWN] button to “OFF” if
you don’t.
4. Press [ENTER] to confirm or Press [MODE/ESC] to return to the main menu.
- Clear lamp time
With this function you can clear the running time of the lamp. Please clear the lamp time every time
you replace the lamp.
1. Select “CLLT” by pressing [UP] or [DOWN] button.
2. Press [ENTER], the display shows “ON” or “OFF”.
3. Press [UP] to select “ON” if you wish to enable this function or press [DOWN] button to “OFF” if
you don’t.
4. Press [ENTER] to confirm or Press [MODE/ESC] to return to the main menu.
- 15 -
XM044 V1.8-NR
- Main menu 5
1. Press [MODE/ESC] to enter the main menu (display flashing).
2. Press [UP] or [DOWN] button to select “EDIT”.
- Define the number of steps in Run
With this function you can define the number of steps in
the Program Run.
1. Select “STEP” by pressing [UP] or [DOWN] button.
2. Press [ENTER], the display shows “S-XX”, “X” stands
for the total amount of steps you want to save, so you
can call up to 48 scenes in “RUN”. For example if the
“XX” is 05, it means that “RUN” will run the first 5 scenes
you saved in “EDIT”.
3. Press [ENTER] to confirm or Press [MODE/ESC] to
return to the main menu.
-Auto Save
With this function you can automatic save the number of
steps in the Program Run.
1. Select “REC” by pressing [UP] or [DOWN] button.
2. Press [ENTER], the display shows “RE.XX”, “XX”
stands for the number from 1 to 400.
3. Press [ENTER] to confirm or Press [MODE/ESC] to
return to the main menu.
- Editing the channels of the individual scenes
With this function you can edit the program to be called
up in Run.
a) Editing via the Control Board
1. Select “SC01” by pressing [UP] or [DOWN] button.
2. Press [ENTER], the display shows “SCXX”, “X”
stands for the scene no. to be edited.
3. Change the scene no. by pressing [UP] or [DOWN] button.
4. Press [ENTER], the display shows “C-X”, “X” stands for the channel no. Such as “C-01”, it
means you are editing channel 1 of the selected scene.
5. Select the channel no. you would like to edit by pressing [UP] or [DOWN] button.
6. Press [ENTER] to enter editing for the selected channel, the fixture reacts to your settings. The
display shows the DMX value of the edited channel. Such as “ 11XX”, it stands for in the channel 11
of the editing scene, the DMX value is XX , XX is a hexadecimal number value “01-FF”.Adjust the
desired DMX value by pressing [UP] or [DOWN] button.
7. Press [ENTER] in order to edit other channels of this scene.
8. Repeat steps 5-9 until you finish setting all the DMX values for all channels of this scene.
9. Once all the channels completed, the display will flash “TIME”
10. Press [ENTER] to edit the time needed, the display shows “TXXX” , “XXX” stands for the time
needed to run the current scene, value “001-999”. E.g., “002” means you need 0.4ms (002*0.2ms) to
run the current scene.
11. Adjust the desired time by pressing [UP] or [DOWN] button.
12. Press [ENTER] to save the settings for the scene you are editing, the display will change to the
next scene automatically.
13. Repeat step 3-14 to edit and other scenes, you can edit and save a maximum of 48 scenes.
- 16 -
XM044 V1.8-NR
14. Press [MODE/ESC] to exit. The number of steps can be defined under “STEP” and the scenes
can be called up under “RUN”
b) Editing via the external controller
Call up the first scene in your controller now.
1. Select “SC01” by pressing [UP] or [DOWN] button.
2. Press [ENTER], the display shows “SC01”.
3. Press [ENTER], the display shows “C-01”.
4. Select "CNIN" by pressing [UP] or [DOWN] button.
5. Press [ENTER], the display shows "OFF".
6. Press [UP] or [DOWN] button .the display shows "ON".
7. Press [ENTER], the display shows "SC02". You successfully downloaded the first scene.
8. Adjust the Step-time as described above under point 12.
9. Call up the second scene in your controller now.
10. Repeat steps 5-11 until all desired scenes are downloaded.
11. Press [MODE/ESC] to exit. The number of steps can be defined under “STEP” and the scenes
can be called up under “RUN”
DMX channel´s functions and their values:
Channel 1 - Color Wheel 1:
0-12
Open / white
13-25 Color 1
26-38 Color 2
39-51 Color 3
52-64 Color 4
65-77 Color 5
78-90 Color 6
91-103 Color 7
104-116 Color 8
117-127 Color 9
128-187 Forwards rainbow effect from fast to slow
188-193 No rotation
194-255 Backwards rainbow effect from slow to fast
Channel 2 - Rotating gobos, cont. rotation:
0-13
Open
14-27 Rot. gobo 1 (metal)
28-41 Rot. gobo 2 (metal)
42-55 Rot. gobo 3 (metal)
56-69 Rot. gobo 4 (metal)
70-83 Rot. gobo 5 (metal)
84-97 Rot. gobo 6 (metal)
98-115 Rot. gobo 7 (metal)
116-135 Rot. gobo 1 (metal) shake
- 17 -
XM044 V1.8-NR
136-155 Rot. gobo 2 (metal) shake
156-175 Rot. gobo 3 (metal) shake
176-195 Rot. gobo 4 (metal) shake
196-215 Rot. gobo 5 (metal) shake
216-235 Rot. gobo 6 (metal) shake
236-255 Rot. gobo 7 (metal) shake
Channel 3 - rotating gobo rotation:
0-7
No rotation
8-127 forwards gobo rotation from fast to slow
128-135 No rotation
136-255 Backwards gobo rotation from slow to fast
Channel 4 - Shutter, strobe:
0-31
Shutter closed
32-63 Dimmer (close to open)
64-95 Strobe effect slow to fast
96-127 No function (shutter open)
128-159 Pulse-effect in sequences
160-191 No function (shutter open)
192-223 Random strobe effect slow to fast
224-255 No function (shutter open)
Channel 5 - PAN movement 8bit :
Channel 6 - TILT movement 8bit :
Channel 7 - Speed pan/tilt movement:
0-225 max to min speed
226-235 blackout by movement
236-245 blackout by all wheel changing
246-255 no function
Channel 8 – reset, internal programs:
0-19
Color change normal
20-39 Color change to any position
40-79 No function
80-99 Motor reset
100-119 Internal program 1
120-139 Internal program 2
- 18 -
XM044 V1.8-NR
140-159 Internal program 3
160-179 Internal program 4
180-199 Internal program 5
200-219 Internal program 6
220-239 Internal program 7
240-255 Internal program 8
CLEANING AND MAINTENANCE
The following points have to be considered during the inspection:
1) All screws for installing the devices or parts of the device have to be tightly
connected and must not be corroded.
2) There must not be any deformations on the housing, color lenses, fixations and
installation spots (ceiling, suspension, trussing).
3) Mechanically moved parts must not show any traces of wearing and must not rotate
with unbalances.
4) The electric power supply cables must not show any damage, material fatigue or
sediments.
Further instructions depending on the installation spot and usage have to be adhered
by a skilled installer and any safety problems have to be removed.
We recommend a frequent cleaning of the device. Please use a moist, lint- free cloth.
Never use alcohol or solvents.
There are no serviceable parts inside the device except for the lamp. Please refer to the
instructions under “Installation instructions”.
Should you need any spare parts, please order genuine parts from your local dealer.
TECHNICAL SPECIFICATIONS
Power supply:
□ 100VAC,50Hz;□ 120VAC, 50Hz;□ 208VAC, 50Hz;□ 220VAC,50Hz; □ 230VAC,50Hz;□ 240VAC, 50Hz;
□ 100VAC,60Hz;□ 120VAC,60Hz; □ 208VAC, 60Hz;□ 220VAC,60Hz;□ 230VAC,60Hz;□ 240VAC,60Hz;
Power consumption: max. 400W
Lamp: MSD250 GY9.5
Packing dimensions: 67.5x37x33cm
Net weight: 11KGS
Gross weight: 13KGS
Remark: errors and omissions for every information given in this manual excepted. All information is
subject to change without prior notice.
- 19 -
XM044 V1.8-NR