The Original Stick Meter

HS26

Introduction

The HS26 is smaller, simpler and more rugged than it’s bigger brothers, and still works with all

Fieldpiece accessory heads. All Fieldpiece accessory heads slide on the top, enabling the user to test a wide variety of parameters. All this plus the removable tip test leads make safe one-handed testing a snap.

For Your Safety

General: Disconnect the test leads before opening the case. Inspect the test leads for damage to the insulation or exposed metal. Replace if suspect.

Never ground yourself when taking electrical measurements. Do not touch exposed metal pipes, outlets, fixtures, etc., which might be at ground potential.

Keep your body isolated from ground by using dry clothing, rubber shoes, rubber mats, or any approved insulating material. When disconnecting from a circuit, disconnect the "RED" lead first, then the common lead. Work with others. Use one hand for testing. Turn off power to the circuit under test before cutting, unsoldering, or breaking the circuit. Keep your fingers behind the finger guards on the probes. Do not measure resistance when circuit is powered. Do not apply more than rated voltage between input and ground.

Voltage tests: Do not apply more than 600VDC or

600VAC to V ranges.

AC tests:

Disconnect the meter from the circuit before turning any inductor off, including motors, transformers, and solenoids. High voltage transients can damage the meter beyond repair. Do not use during electrical storms.

Maintenance

Clean the exterior with clean dry cloth. Do not use liquid.

Battery replacement:

When the multimeter displays " " the battery must be replaced. Disconnect and unplug leads, turn meter off, and remove the battery cover. Replace the battery with a NEDA type 1604

9V battery.

Symbols Used

!

Caution, refer to manual.

Ground

Double insulation

Alternating current

Direct current

!

WARNINGS

!

DISCONNECT AND UNPLUG TEST LEADS before opening case.

This instrument complies with the requirements of the following European Community Directives:

89/336/EEC (Electromagnetic Compatibility) and

73/23/EEC (Low Voltage) as amended by 93/68/EEC

(CE Marking).

OPERATOR’S MANUAL

SPECIFICATIONS

Display: 3½ digit liquid crystal display (LCD) with a maximum reading of 1999.

Overrange: "OL" mark indication.

Auto power off: approx 60 minutes.

Operating environment:

32 to 122 °F (0 to 50°C) at

<70% R.H.

Storage temperature: -4 to 140 °F (-20 to 60°C), 0 to 80% R.H. with battery removed.

Accuracy: Specifications good in ambient conditions of 73 °F ±9°F (23°C ±5°C), <75% relative humidity.

Temperature Coefficient:

0.1

×(specified accuracy) per °F/°C. (32 to 64°F(0 to 18°C), 82 to 122°F(28 to 50°C)).

Power: Single standard 9-volt battery, NEDA 1604,

JIS 006P, IEC 6F22.

Battery life:

150 hours typical with carbon zinc,

300 hours typical with alkaline.

Accessories: 400AAC current clamp, one pair test leads, one pair alligator clips, carrying case, 9V battery (installed), and operating instructions.

AC Volts (50Hz - 500Hz)

Ranges: 200mV, 2000mV, 200V, 600V

Resolution:

0.1mV

Accuracy:

±(1.2% rdg + 3 dgts)

±(2.0% rdg + 5 dgts) on 600V range

Input impedance: 1M Ω

Overload protection: 600VDC or AC rms,

600VDC/AC rms 15 sec on 200mV range

Transient protection: 6kV for 10μ sec

Diode Test

Test current:

∼1mA

Accuracy:

±(1.5% rdg + 3 dgts)

Open circuit volts:

3.0VDC typical

Overload protection: 500VDC or AC rms

Continuity

Audible indication: Less than 100 Ω

Visual indication: Green LED will be on continuously.

Response time: 100ms

Overload protection:

500VDC or AC rms

Capacitance (MFD)

Range: 200 μF

Resolution: 0.1

μF

Test frequency: 42Hz

Test voltage: <3.0V

Accuracy:

±(3% rdg + 5 dgts)

Overload protection: 500VDC or AC rms

DC Current

Ranges:

200 μA

Resolution: 0.1

μA

Accuracy:

±( 1.0% rdg + 2 dgts)

Voltage burden: 1V

Overload protection: 500VDC or AC rms

DC Volts

Ranges: 200mV, 2000mV, 200V

Resolution: 0.1mV

Accuracy:

±(0.5% rdg + 1 dgt)

Input impedance: 1M Ω

Overload protection:

600VDC or AC rms,

600VDC/AC rms 15 sec on 200mV range

Transient protection: 6kV for 10μ sec

Resistance

Ranges: 200 Ω

Resolution: 0.1

Ω

Accuracy:

±(1.0% rdg + 3 dgts)

Open circuit volts: 3.0VDC typical

Overload protection:

500VDC or AC rms

Safety

Conforms to UL61010-1, CE (EN61010-1), CATIII

600V, Class II, Pollution Degree 2, Indoor Use Only.

CATIII : Is for measurements performed in the building installation.

EMC

: Conforms to EN61326-1.

Limited Warranty

This meter is warranted against defects in material or workmanship for one year from date of purchase. Fieldpiece will replace or repair the defective unit, at its option, subject to verification of the defect.

This warranty does not apply to defects resulting from abuse, neglect, accident, unauthorized repair, alteration, or unreasonable use of the instrument.

Any implied warranties arising from the sale of a

Fieldpiece product, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the above.

Fieldpiece shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim of such damage, expenses, or economic loss.

State laws vary. The above limitations or exclusions may not apply to you.

Obtaining Service

Call Fieldpiece Instruments for one-price-fix-all warranty service pricing. Send check or money order for the amount quoted. Send the meter freight prepaid to Fieldpiece Instruments. Send proof of date and location of purchase for in-warranty service. The meter will be repaired or replaced, at the option of

Fieldpiece, and returned via least cost transportation.

Selecting Ranges

For DC voltage, set the meter to the VDC parameter instead of VAC (shown below).

For all ranges choose a range just above the value you expect. If display reads “OL” (overload), select a higher range. If display shows less than three numbers, select a lower range for better resolution.

Voltage

Diode Test

600

200

V

AC

2000m

200

V

DC

2000m

200m

MFD

200

Ω

200

200m

µA

DC

200

600

200

V

AC

2000m

200

V

DC

2000m

200m

MFD

200

Ω

200

200m

µA

DC

200

Capacitance

Resistance

600

200

V

AC

2000m

200

V

DC

2000m

200m

MFD

200

Ω

200

200m

µA DC

200

Works With Fieldpiece Accessory

Heads!

CLAMP

CAT.III

AC Current

Clamp

1AAC / 1mVAC

400AAC MAX

!

ACH4

V Ω COM

300V

400A

600

200

V AC

2000m

200

V

DC

2000m

200m

MFD

200

Ω

200

200m

µA

DC

200

Flame rectification

600

200

V

AC

2000m

200

V

DC

2000m

200m

MFD

200

Ω

200

200m

µA

DC

200

MAX HOLD

600

200

V

AC

2000m

200

V

DC

2000m

200m

MFD

200

Ω

200

µA

DC

200

200m

MAX HOLD

600

200

V

AC

2000m

200

V

DC

2000m

200m

MFD

200

Ω

200

200

200m

The Original Stick Meter

HS26

The Original Stick Meter

HS26

(1) (2)

Connect to Fieldpiece accessory heads by simply attaching them to the top of meter (1) or attach remotely through leads (2). For most heads, move dial to mVDC range shown (1). For the AAC clamp

(ACH4), move dial to VAC range (2).

Hi Voltage Indicator

In any VAC/VDC range, when you touch a voltage greater than 30V, the beeper will beep and the red Hi-

V LED will blink. BE CAREFUL!

Capacitance

For motor-start and motor-run capacitors.

Disconnect the capacitor from power first. Short the terminals to discharge the capacitor. Disconnect any resistors that might be between the terminals of the capacitor.

MAX and Data HOLD

Press MAX to store highest reading on the display.

Press MAX again to return display to real-time reading. Press HOLD to hold current data on the display.

Silicone Leads

Because the wire insulation is silicone the leads will stay flexible in cold weather and will not melt if bumped by a soldering iron.

Safe One-Handed Testing

When testing electrical circuits with two hands, there is a risk that a careless mistake may complete a circuit through your body and potentially cause death or injury.

First disconnect the top half of red test lead and plug tip directly

V Ω COM into Volts jack. Plug alligator clip lead into the COM jack (you may need to use a lead with tip removed as an extension). Then clip the alligator lead to one test

MAX

600

200

V

AC

2000m

HOLD

200

V

DC

2000m point.

With the black alligator lead secured, you’re now free to hold the meter with one hand and touch other test points with the probe tip.

200m

MFD

200

Ω

200

200m

µA DC

200

The Original Stick Meter

HS26

Modular Expandability

Modular expandability is the ability for accessory heads and meters to change configurations to match the various needs of an HVAC/R technician.

on

TA

LE

L att

Fuel

Ty pe

R e friger

ST

AB

LE

ON ng

R1

34

A

LO

BAT

T

SH

EN GL

IS

H

ME

TR

IC

SC

R4

04

A or

Te

SC mp re

SH

Pr essu

Se

AT

M

T/

C

Ca

O-

AUT F

OF

AS

4

EM

%

CO

°C

°F

T/C

CAL

AU

TO

FF

AO

CLAMP

CAT.III

AC Current

Clamp

1AAC / 1mVAC

400AAC MAX

!

ACH4

300V

400A

English

&

Air

Te

Ft/m

MPH in

ºF

OF

F

Metri c

KM/h M/s

ºC r m pe cit re

Englis

Metric

LO

BAT

T

ON

RE

AD

LC

100

D

X h

(16 erage sec)

AA

V3

AUT

F

O

Accessory Heads

Accessory heads, like the included ACH4, are the sensors of multiple parameters measured by technicians every day. They plug into a mV range (depending on the head) of a multimeter. The multimeter will display whatever the head is measuring. Instead of having to purchase and carry a separate instrument for each parameter, a technician can use multiple heads and a single multimeter to do the job.

Here are four of the many heads available:

AAV3 Air Velocity and Temperature

ADMN2 Dual-Port Manometer

AVG2 Digital Vacuum Gauge

AOX2 Combustion Check aaaaa aaaaa aaaaa aaaaa

Accessory heads (the sensors) send a mV signal, which represents the value of the parameter being tested. Heads can attach directly to the top of a Stick meter, DL3 data logger, or EHDL1. They can also plug into any meter with mV ranges using ADLS2 leads.

ON

LCD X

100

LO BATT

Air Velocity

& Temperature

Head

English

READ

Average

(16 sec)

English Metric

Ft/min

MPH

ºF

OFF

M/s

KM/hr

ºC

Metric Real time

AAV3

AUTO-

OFF

P1 P2

Dual-Port

Manometer

Accessory

Head

0.1

ON

Lo Batt

ENGLISH

Resolution

0.01

(LCD/10)

METRIC

P1-P2

P2

P1

ZERO AUTO

OFF

ADMN2

Combustion

Check

ON

STABLE Lo Batt

Fuel Type

GAS

OIL

TEMP

% CO

%

O

2

2

°C °F T/C

CAL

AUTO

OFF

AOX2

AAV3 ADMN2 AVG2 AOX2

Opman HS26 v214

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement