® 1000A AC/DC TRMS DIGITAL CLAMPMETER
An ISO 9001:2008 Company
SPECIAL FEATURES :
˜
˜ MAX/MIN/AVG Recording mode (Auto ranging)
˜ VFD-V & Hz for fundamental V/Hz of most Variable-Frequency-Drives
˜ Display Hold & Non-Contact EF-Detection (NCV)
˜ Back-lighted easy-to-read LCD display
˜ Flashlight for easy operation in dim areas
˜ Fast 80ms Peak-RMS mode to capture in-rush currents
˜ Auto-ranging Relative mode with DC-Zero mode &
5ms Crest (Instantaneous Peak-Hold) mode
WITH VFD, EF-DETECTION
MODEL KM 088
27 Functions 46 Ranges
NEW
GENERAL SPECIFICATIONS :
í Sensing : AC; True RMS
í Jaws Opening size & conductor diameter : 51mm Max.
í Display : 3-5/6 digits 6000 counts
í Update Rate : 5 per second nominal
í Polarity : Automatic
í Operating Temperature : -10ºC to 50ºC
í Relative Humidity : Non condensing ( £ 10ºC ) Maximum 90%R.H. at 10-30°C
decreasing linearly to 75% R.H. at 30-40°C & 45% R.H. at 40-50°C
í Altitude : Operating below 2000m; Storage below 12000m
í Storage Temperature : -20°C ~ 60°C, <80% R.H. (with battery removed)
í Temperature Coefficient : Nominal 0.10 x (specified accuracy) / C @ (-10 C –– 18 C or 28 C –– 50 C),
or otherwise Specified
í Power Supply : Standard 1.5V AA Battery x 2
í Power Consumption : typical 13mA for Current Functions
í Low Battery : Below approx. 2.85V for Capacitance & Hz
Below approx. 2.5V for other functions
í APO timing : Idle for 32 minutes
í APO Consumption : typical 5 m A
í Dimension : 258(L) x 94(W) x 44(H)mm
í Weight : approx 392 gms.
SAFETY :
˜ Safety : Double insulation per UL/IEC/EN61010-1 Ed. 3.0, IEC/EN61010-2-033 Ed. 1.0,
CAN/CSA C22.2 No. 61010-1 Ed. 3.0, IEC/EN61010-2-032 Ed. 3.0 & IEC/EN61010-031 Ed. 1.1
˜ Measurement Category : CAT III 1000V AND CAT IV 600V AC & DC
˜ E.M.C. : Meets EN61326-1 : 2006 (EN55022, EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3,
EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11) :
ACA, DCA and DC+ACA Functions, in an RF field of 1V/m :
Total Accuracy = Specified Accuracy + 60 digits at around 200MHz~350MHz
DC m A and Ohm Functions, in an RF field of 1V/m : Total Accuracy = Specified Accuracy + 80 digits
Other Functions, in an RF field of 3V/m : Total Accuracy = Specified Accuracy + 20 digits
˜ Overload Protection :
Current & Hz functions via jaws : 1000ADC/AAC rms at <400Hz
Other functions via terminals : 1000VDC/ VAC rms
˜ Pollution Degree : 2
˜ Transient Protection : 8.0kV (1.2/50 m s surge)
˜ Rugged Fire retarded casing.
˜ LVD EN61010-2-032/EN61010-2-033 to CAT III 1000V & CAT IV 600V
Preliminary Data
ACCESSORIES :
Test leads set, Users Manual, Soft carrying pouch.
All Specifications are subject to change without prior notice.
Chhaya com/D/chhaya/my documents/chhaya/backup/catlog/New catlog/2013-2014/KM 088 Revised.cdr
ELECTRICAL SPECIFICATIONS : KM 088
o o
Accuracy is ± (% of reading digits + number of digits) or otherwise specified, at 23 C ± 5 C
Maximum Crest Factor <2.5:1 at full scale & <5:1 at half scale or otherwise specified, and with frequency spectrum not exceeding the specified frequency bandwidth for non-sinusoidal waveforms.
TM
AmpTip Clamp-on AC Current :
Range Resolution Accuracy 1) 2) 3)
40Hz ~ 100Hz
00.00A~20.00A
20.00A~60.00A
10 mA
10 mA
±(1.5%rdg+5dgts)
±(3.0%rdg+5dgts)
100Hz ~ 400Hz
00.00A~20.00A
10 mA ±(2.0%rdg+5dgts)
20.00A~60.00A
10 mA ±(3.0%rdg+5dgts)
1)
Induced error from adjacent current-carrying conductor :
< 0.02A/A
2)
Specified with Relative Zero D mode applied to offset the
non-zero residual readings, if any
3)
Add 10d to the specified accuracy @ < 4A
REGULAR CLAMP-ON DC CURRENT
Range Resolution Accuracy
1) 2)
60.00 A 3) 0.01 A
600.0 A 0.1 A ±(1.8%rdg + 5dgts)
1000 A 1 A
1) Induced error from adjacent current-carrying conductor : < 0.02A/A
2) Specified with DC-Zero mode applied to offset the non-zero residual readings,
if any
3) Add 10d to the specified accuracy @ < 9A
REGULAR CLAMP-ON AC CURRENT
Range Resolution Accuracy
1) 2)
40Hz ~ 100Hz
60.00 A
2)
0.01 A
600.0 A
1000 A
3)
0.1 A
1 A
±(1.8%rdg + 5dgts)
100Hz ~ 400Hz
60.00 A
2)
0.01 A
600.0 A
1000 A
3)
0.1 A
1 A
±(2.2%rdg + 5dgts)
1) Induced error from adjacent current-carrying conductor : < 0.02A/A
2)
Add 10d to the specified accuracy @ < 9A
3)
Maximum Crest Factor < 1.4 : 1 at full scale & < 2.8 : 1 at half scale
DC + AC VOLTAGE (with Digital Low-pass Filter)
Range Resolution Accuracy
50Hz ~ 60Hz
600.0 V 0.1 V
1 V 1000 V
DC, 40Hz ~ 200Hz
600.0 V 0.1 V
1 V 1000 V
200Hz ~ 400Hz
600.0 V 0.1 V
1000 V 1 V
Input Impedance : 10M W , 100pF nominal
±(1.0%rdg + 7dgts)
±(1.8%rdg + 7dgts)
±(12%rdg + 7dgts)
TM
AmpTip Clamp-on DC+AC Current :
Range Resolution
DC, 40Hz ~ 100Hz
00.00A~20.00A
20.00A~60.00A
100Hz ~ 400Hz
00.00A~20.00A
20.00A~60.00A
10 mA
10 mA
10 mA
10 mA
Accuracy 1) 2) 3)
±(2.0%rdg + 7dgts)
±(3.0%rdg + 7dgts)
±(2.2%rdg + 7dgts)
±(3.0%rdg + 7dgts)
1) Induced error from adjacent current-carrying conductor : < 0.08A/A
2)
Specified with DC-Zero mode applied to offset the non-zero residual
readings, if any
3) Add 10d to the specified accuracy @ < 4A
TM
AmpTip Clamp-on DC Current :
Range
00.00A~20.00A
20.00A~60.00A
Resolution
10 mA
10 mA
Accuracy 1) 2) 3)
±(1.5%rdg + 5dgts)
±(3.0%rdg + 5dgts)
1) Induced error from adjacent current-carrying conductor : < 0.02A/A
2)
Specified with DC-Zero mode applied to offset the non-zero residual
readings, if any
3) Add 10d to the specified accuracy @ < 4A
REGULAR CLAMP-ON DC + AC CURRENT
Range Resolution Accuracy
1) 2)
DC, 40Hz ~ 100Hz
60.00 A
3) 0.01 A
600.0 A
1000 A
4)
0.1 A
1 A
±(2.2%rdg + 7dgts)
100Hz ~ 400Hz
60.00 A
3) 0.01 A
600.0 A
1000 A
4)
0.1 A
1 A
±(2.5%rdg + 7dgts)
1)
Induced error from adjacent current-carrying conductor : < 0.08A/A
2)
Specified with DC-Zero mode applied to offset the non-zero residual readings,
if any
3)
Add 10d to the specified accuracy @ < 9A
4) Maximum Crest Factor < 1.4 : 1 at full scale & < 2.8 : 1 at half scale
AC VOLTAGE (with Digital Low-Pass Filter)
Range Resolution Accuracy
50Hz ~ 60Hz
600.0 V 0.1 V
±(0.8%rdg + 5dgts)
1 V 1000 V
20Hz ~ 200Hz
600.0 V 0.1 V
±(1.5%rdg + 5dgts)
1 V 1000 V
200Hz ~ 400Hz
0.1 V 600.0 V
1000 V 1 V
±(10%rdg + 5dgts)
Input Impedance : 10M W , 100pF nominal
All Specifications are subject to change without prior notice.
Chhaya com/D/chhaya/my documents/chhaya/backup/catlog/New catlog/2013-2014/KM 088 Revised.cdr
ELECTRICAL SPECIFICATIONS : KM 088
DC VOLTAGE
Range
600.0 V
1000 V
Resolution
0.1 V
1 V
Accuracy
±(0.8%rdg + 5dgts)
RESISTANCE
Range
600.0
W
6.000K
60.00K
W
W
Resolution
0.1 W
1 W
10 W
Open Circuit Voltage : 1.0VDC typical
Accuracy
±(1.0%rdg + 5dgts)
Hz Line Level Frequency
Function
(Sine RMS)
Range
600 V
1000 V
TM
60 A (AmpTip )
60 A
600 A
1000A
50 V
20 A
20 A
5.00Hz~999.9Hz
40.00Hz~400.0Hz
40.00Hz~400.0Hz
Accuracy : ±(1%rdg + 5dgts)
1) DC-bias, if any, not more than 50% of Sine RMS.
CAPACITANCE
Range
200.0 m F
2500 m F
Resolution
0.1 m F
1 m F
1) Accuracies with film capacitor or better
Accuracy 1)
±(2.0%rdg + 4dgts)
Non-Contact EF-Detection
Typical Voltage
20V (tolerance : 10V~36V)
55V (tolerance : 23V~83V)
110V (tolerance : 59V~165V)
220V (tolerance : 124V~330V)
440V (tolerance : 250V~1000V)
Bar-Graph Indication
-
- -
- - -
- - - -
- - - - -
Indication : Bar-graph segments & audible beep tones proportional to the field strength
Detection Frequency : 50/60Hz
Detection Antenna : Inside the top side of the stationary jaw
Probe-Contact EF-Detection : For more precise indication of live wires, such as distinguishing between live and ground connections, use one s ingle probe to test via terminal COM for direct EF-Detection with best sensitivity.
DIODE TESTER
Range
2.000 V
Resolution
1 mV
Test Current : 0.3mA typically
Open Circuit Voltage : < 3.5VDC typically
Accuracy 1)
±(1.5%rdg + 5dgts)
AUDIBLE CONTINUITY TESTER
Audible Threshold Between 10 and 250 W
Response Time 32ms approx.
PEAK-RMS (ACV & ACA)
Response 80ms to >90%
CREST (PEAK-HOLD)
Accuracy
Add 250 digits to specified accuracy for changes > 5ms
All specifications are subject to change without prior notice.
An ISO 9001:2008 Company
®
G-17, Bharat Industrial Estate, T. J. Road, Sewree (W), Mumbai - 400 015. INDIA.
Sales Direct.:
022-24156638,
Tel. :
022-24124540, 24181649,
Fax :
022-24149659
Email :
Website :
www.kusamelectrical.com
Chhaya com/D/chhaya/my documents/chhaya/backup/catlog/New catlog/2013-2014/KM 088 Revised.cdr
LIST OF PRODUCTS
¬ Digital AC & AC/DC Clampmeter
¬ AC/DC Current Adaptor
¬ Thermo Hygrometer
¬ Digital Lux Meter
¬ Power Factor Regulator
¬ Digital Panel Meters
¬ High Voltage Detector
¬ Gas Analysers
¬ Function Generator
¬ Battery Tester
¬ Solar Power Meter
Resistance Testers(upto 10 KV)
®
G 17, Bharat Industrial Estate, T. J. Road,
Sewree (W), Mumbai - 400 015. INDIA.
Sales Direct :
(022) 24156638
Tel. :
(022) 24124540, 24181649.
Fax :
(022) 24149659
Email :
[email protected]
Website :
www.kusamelectrical.com
www.kusam-meco.co.in
AN ISO 9001:2008 COMPANY
1000A AC/DC TRUE RMS
DIGITAL CLAMPMETER
WITH VFD, EF-DETECTION,
FOR LOW CURRENT
MEASUREMENT
MODEL - KM 088
OPERATION MANUAL
®
TRMS
DIGITAL CLAMPMETER
MODEL - KM 088
®
I. SAFETY :
This manual contains information and warnings that must be followed for operating the instrument safely and maintaining the instrument in a safe operating condition. If the instrument is used in manner not specified by the manufacturer, the protection provided by the instrument may be impaired.
The meter protection rating, against the users, is double insulation per UL/IEC/EN61010-1 Ed. 3, IEC/EN61010-2-033 Ed. 1, CAN/
CSA C22.2 No. 61010-1 Ed. 3, IEC/EN61010-2-032 Ed. 2 & IEC/
EN61010-031 Ed. 1.1 :
Measurement Category III 1000V & Category IV 600V AC & DC.
Per IEC610-1 (2010) OVERVOLTAGE CATEGORY
OVERVOLTAGE CATEGORY II (CAT II) is for equipment intended to be supplied from the building wiring. It applies both to plugconnected equipment and to PERMANENTLY CONNECTED
EQUIPMENT.
OVERVOLTAGE CATEGORY III (CAT III) is for equipment intended to form part of a building wiring installation. Such equipment includes socket outlets, fuse panels, and some MAINS installation control equipment.
OVERVOLTAGE CATEGORY IV (CAT IV) is for equipment installed at or near the origin of the electrical supply to a building, between the building entrance and the main distribution board. Such equipment may include electricity tariff meters and primary over current protection devices.
Terms in this manual :
WARNING Identifies conditions and actions that could result in serious injury or even death to the user.
CAUTION Identifies conditions and actions that could cause damage or malfunction in the instrument.
01
®
WARNING :
To reduce the risk of fire or electric shock, do not expose this product to rain or moisture. The meter is intended only for indoor use.
To avoid electrical shock hazard, observe the proper safety precautions when working with voltages above 60 VDC or 30 VAC rms. These voltage levels pose a potential shock hazard to the user.
Before and after hazardous voltage measurements test the voltage function on a known source such as line voltage to determine proper meter functioning.
Keep your hands/fingers behind the hand/finger barriers (of the meter and the test leads) that indicate the limits of safe access of the handheld part during measurement. Inspect test leads, connectors and probes for damaged insulation or exposed metal before using the instrument. If any defects are found, replace them immediately. Only use the test lead provided with the equipment or UL Listed Probe
Assembly rated CAT III 1000V or better.
This Clamp-on meter is designed to apply around or remove from uninsulated hazardous live conductors. But still, individual protective equipment must be used if hazardous live parts in the installation where measurement is to be carried out could be accessible.
CAUTION :
Disconnect the test leads from the test points before changing meter functions.
02
®
II. INTERNATIONAL ELECTRICAL SYMBOLS :
Caution ! Refer to the explanation in this Manual.
Caution ! Risk of electric shock.
Earth (Ground)
Double Insulation or Reinforced insulation
Fuse
AC--Alternating Current
DC--Direct Current
Application around and removal from hazardous live conductors is permitted.
III. CENELEC Directives :
The instruments conform to CENELEC Low-voltage directive 2006/
95/EC and Electromagnetic compatibility directive 2004/108/EC.
6.
7.
8.
2.
3.
4.
5.
IV. SPECIAL FEATURES :
1.
9.
TM
AmpTip low-current range calibrated at Jaw-tip for slimconditions
MAX/MIN/AVG Recording mode (Auto ranging)
Display Hold
Non-Contact EF-Detection (NCV)
Back-lighted easy-to-read LCD display
Flashlight for easy operation in dim areas
Fast 80ms Peak-RMS mode to capture in-rush currents
Relative mode (Auto-ranging) with DC-Zero mode on DCA,
DC+ACA ranges
5ms Crest (Instantaneous Peak-Hold) mode
03
®
V. SPECIFICATIONS :
GENERAL SPECIFICATIONS :
Display : 3-5/6 digits 6000 counts
Polarity : Automatic
Jaw opening & Conductor diameter : 51mm max
Update Rate : 5 per second nominal
Operating Temperature : -10ºC to 50ºC
Relative Humidity : Non condensing ( 10ºC)
90% RH(at 10-30ºC)
75% RH(at 30-40ºC)
45% RH(at 40-50ºC)
Pollution degree : 2
Storage Temperature : -20ºC to 60ºC, < 80% R.H.
(with battery removed)
Altitude : Operating below 2000m;
Storage below 12000m
Temperature Coefficient : Nominal 0.10 × (specified accuracy)/ºC
@(-10ºC—18ºC or 28ºC—50ºC), or
otherwise specified
Sensing : True RMS
Low Battery : Below approx. 2.85V for Capacitance
& Hz, Below approx. 2.5V for other
functions
APO Timing : Idle for 32 minutes
Power Consumption : Approx. 13mA for Current functions
APO Consumption : 5 m
Power Supply : 1.5V AA Size battery X 2
Dimension : 258(L) x 94(W) x 44(H)mm
Weight : Approx. 392gm
Accessories : Test leads set, User Manual, Soft
carrying pouch
04
®
SAFETY :
Safety : Double insulation per UL/IEC/EN61010
-1 Ed. 3.0, IEC/EN61010-2-033 Ed. 1.0,
CAN/CSA C22.2 No. 61010-1 Ed. 3.0,
IEC/EN61010-2-032 Ed. 2 & IEC/
EN61010-031 Ed. 1.1
Measurement Category : CAT III 600V & CAT IV 300V AC & DC
Transient Protection : 8.0kV (1.2/50 m
Overload Protection :
Current & Hz functions via jaws : 1000A DC/AC rms at < 400Hz
Voltage & 3-Phase Rotation functions via terminals : 1100VDC/ VAC rms
Other functions via terminals : 1000VDC/ VAC rms
E.M.C. :
Meets EN61326-1 : 2006 (EN55022, EN61000-3-2, EN61000-3-3,
EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5,
EN61000-4-6, EN61000-4-8, EN61000-4-11) :
ACA, DCA and DC+ACA Functions, in an RF field of 1V/m :
Total Accuracy = Specified Accuracy + 60 digits
@ 200MHz~350MHz
DC m
Total Accuracy = Specified Accuracy + 80 digits
Other Functions, in an RF field of 3V/m :
Total Accuracy = Specified Accuracy + 20 digits
VFD-V & Hz for fundamental V/Hz of most Variable-Frequency-Drives.
Rugged fire retarded casing with battery access door.
05
®
ELECTRICAL SPECIFICATIONS :
Accuracy is ± (% of reading digits + number of digits) or otherwise specified @
23ºC ± 5ºC. Maximum Crest Factor < 2.5:1 at full scale & < 5:1 at half scale or otherwise specified, and with frequency spectrum not exceeding the specified frequency bandwidth for non-sinusoidal waveforms.
Regular Clamp-on AC Current :
Range Resolution
40Hz ~ 100Hz
60.00 A 2)
600.0 A
1000 A 3)
10 mA
100 mA
1 A
Accuracy 1) 2)
±(1.8%rdg + 5dgts)
100Hz ~ 400Hz
60.00 A 2)
600.0 A
1000 A 3)
10 mA
100 mA
1 A
±(2.2%rdg + 5dgts)
1) Induced error from adjacent current-carrying conductor : < 0.02A/A
2)
Add 10d to the specified accuracy @ < 9A
3) Maximum Crest Factor < 1.4 : 1 at full scale & < 2.8 : 1 at half scale.
Regular Clamp-on DC Current :
Range Resolution
60.00 A 3)
600.0 A
1000 A
10 mA
100 mA
1 A
Accuracy 1) 2)
±(1.8%rdg + 5dgts)
1) Induced error from adjacent current-carrying conductor : < 0.02A/A
2)
Specified with DC-Zero mode applied to offset the non-zero residual
readings, if any
3)
Add 10d to the specified accuracy @ < 9A
06
®
Regular Clamp-on DC+AC Current :
Range Resolution Accuracy 1) 2)
DC, 40Hz ~ 100Hz
60.00 A 3)
600.0 A
1000 A 4)
10 mA
100 mA
1 A
±(2.2%rdg + 7dgts)
100Hz ~ 400Hz
60.00 A 3)
600.0 A
1000 A 4)
10 mA
100 mA
1 A
±(2.5%rdg + 7dgts)
1) Induced error from adjacent current-carrying conductor : < 0.08A/A
2)
Specified with DC-Zero mode applied to offset the non-zero residual
readings, if any
3)
Add 10d to the specified accuracy @ < 9A
4) Maximum Crest Factor < 1.4 : 1 at full scale & < 2.8 : 1 at half scale
TM
AmpTip Clamp-on AC Current :
Range Resolution Accuracy 1) 2) 3)
40Hz ~ 100Hz
60.00 A 10 mA ±(1.5%rdg + 5dgts)
100Hz ~ 400Hz
60.00 A 10 mA ±(2.0%rdg + 5dgts)
1)
Induced error from adjacent current-carrying conductor : < 0.02A/A
2)
Specified with Relative Zero D
residual readings, if any
3)
Add 10d to the specified accuracy @ < 4A
07
®
TM
AmpTip Clamp-on DC Current :
Range
60.00 A
Resolution
10 mA
Accuracy 1) 2) 3)
±(1.5%rdg + 5dgts)
1)
Induced error from adjacent current-carrying conductor : < 0.02A/A
2)
Specified with DC-Zero mode applied to offset the non-zero residual
readings, if any
3)
Add 10d to the specified accuracy @ < 4A
TM
AmpTip Clamp-on DC+AC Current :
Range Resolution Accuracy 1) 2) 3)
DC, 40Hz ~ 100Hz
60.00 A 10 mA
100Hz ~ 400Hz
60.00 A 10 mA
±(2.0%rdg + 7dgts)
±(2.2%rdg + 7dgts)
1) Induced error from adjacent current-carrying conductor : < 0.08A/A
2)
Specified with DC-Zero mode applied to offset the non-zero residual
readings, if any
3)
Add 10d to the specified accuracy @ < 4A
AC Voltage (with Digital Low-pass Filter) :
Range Resolution Accuracy
50Hz ~ 60Hz
600.0 V
1000 V
20Hz ~ 200Hz
0.1 V
1 V
±(0.8%rdg + 5dgts)
600.0 V
1000 V
0.1 V
1 V
±(1.5%rdg + 5dgts)
200Hz ~ 400Hz
600.0 V
1000 V
0.1 V
1 V
±(10%rdg + 5dgts)
Input Impedance : 10M W
08
®
DC Voltage :
Range
600.0 V
1000 V
Resolution
0.1 V
1 V
Accuracy
±(0.8%rdg + 5dgts)
Input Impedance : 10M W
DC+AC Voltage (with Digital Low-pass Filter) :
Range Resolution Accuracy
50Hz ~ 60Hz
600.0 V
1000 V
0.1 V
1 V
±(1.0%rdg + 7dgts)
DC, 40Hz ~ 200Hz
600.0 V
1000 V
200Hz ~ 400Hz
0.1 V
1 V
±(1.8%rdg + 7dgts)
600.0 V
1000 V
0.1 V
1 V
±(12%rdg + 7dgts)
Input Impedance : 10M W
Resistance :
Range Resolution
600.0 W 0.1 W
6.000 K W 1
60.00 K W 10 W
Open Circuit Voltage : 1.0VDC typical
Accuracy
Capacitance :
Range Accuracy 1)
Resolution
200.0 m
2500 m
0.1 m
±(2.0%rdg + 4dgts)
1 m
1) Accuracies with film capacitor or better.
09
®
Hz Line Level Frequency :
Function
Sensitivity 1)
(Sine RMS)
600 V
1000 V
50 V
20 A
60 A
600 A
1000 A
20 A
Range
5.00Hz~999.9Hz
40.00Hz~400.0Hz
40.00Hz~400.0Hz
Accuracy : ±(1%rdg + 5dgts)
1)
DC-bias, if any, not more than 50% of Sine RMS.
Non-Contact EF-Detection :
Typical Voltage
20V (tolerance : 10V~36V)
55V (tolerance : 23V~83V)
110V (tolerance : 59V~165V)
220V (tolerance : 124V~330V)
440V (tolerance : 250V~1000V)
Bar-Graph Indication
-
- -
- - -
- - - -
- - - - -
Indication : Bar-graph segments & audible beep tones proportional to the field strength.
Detection Frequency : 50/60Hz.
Detection Antenna : Inside the top side of the stationary jaw.
Probe-Contact EF-Detection : For more precise indication of live wires, such as distinguishing between live and ground connections, use one single probe to test via terminal COM for direct contact EF-Detection with best sensitivity.
10
®
PEAK-rms (ACV & ACA) :
Response 80ms to >90%
CREST (Peak-Hold) :
Accuracy
Add 250 digits to specified accuracy for changes >5ms
Audible Continuity Tester :
Audible Threshold
Response time
Between 10 W
32ms approx.
.
Diode Tester :
Range Resolution Accuracy 1)
±(1.5%rdg + 5dgts) 2.000 V 1 mV
Test Current : 0.3mA typically
Open Circuit Voltage : < 3.5VDC typically
11
®
VI. PRODUCT DESCRIPTION :
This manual uses only representative model(s) for illustrations.
Please refer specification details for function availability to this model.
12
11
10
9
8
8
7
+
AC–DC TRMS
MAX 1000A
1000V CAT III
600V CAT IV
W
Hz
+
A
Hz
+
A
EF
Hz
+
V
OFF
HOLD
H
ZERO
+
AUTO
+ –
C R
H
MAX MIN AVG
VFD
P-RMS 8888
. . .
Mk F
AV
PEAK-RMS
R REC
SELECT
C
CREST
Hz
L1
COM
L3
CAT III
1000V
CAT IV
600V mpTip TM Jaws
Clamp-on DMM
+
L2
+
1
2
3
4
5
6
1. Antenna area for Non-Contact EF-
Detection
2. Jaw center indicator (with DCA polarity), at where best current accuracy is specified.
3. Rotary Selector to turn the power
ON/OFF and Select a function.
4. 3-5/6 digits 6000 counts numeric
LCD display.
5. Additional input Jack for Phase
Rotation function only.
6. Input Jack for all functions EXCEPT non-invasive DCA, DC+ACA, or ACA current functions.
7. Common (Ground reference) Input
Jack for all functions EXCEPT noninvasive DCA, DC+ACA, or ACA current functions.
8. Push-buttons for special functions & features.
9. Jaw trigger for opening the clamp jaw.
10. Hand/Finger Barrier to indicate the limits of safe access of the meter.
11. Clamp Jaw for DC or AC current magnetic field pick up.
12. Additional center indicator for
TM
AmpTip Low-current function, at is specified.
12
®
VII. OPERATION :
WARNING : Before and after hazardous voltage measurements, test the voltage function on a known source such as line voltage to determine proper meter functioning.
ACV, DCV, DC+ACV, EF (NCV), & Line-level Hz functions :
Inputs, other than that of EF as described below, are made through the test lead terminals COM/+ . Press SELECT button momentarily to select the subject functions in sequence. Last selection will be saved as power up default for repeat measurement convenience.
Press Hz button momentarily to toggle the Line-level Hz function.
+ + +
MAX 1000A
1000V CAT III
600V CAT IV
W
Hz
+
A
Hz
+
A
EF
Hz
+
V
OFF
ZERO
HOLD
H
VFD
VFD
3802
.
V
EF
Hz
+
V
PEAK-RMS
R REC SELECT
C CREST
Hz
L1
COM
L3
CAT III
1000V
CAT IV
600V
+
L2
MAX 1000A
1000V CAT III
600V CAT IV
W
Hz
+
A
Hz
+
A
EF
Hz
+
V
OFF
ZERO
HOLD
H
SELECT
PEAK-RMS
0 i45
V
C CREST
Hz
R REC SELECT
1
L3
L1
COM
CAT III
1000V
CAT IV
600V
+
L2
+ +
MAX 1000A
1000V CAT III
600V CAT IV
W
+
A
Hz
Hz
+
A
+
EF
Hz
+
V
OFF
HOLD
H
ZERO
VFD
+
VFD
3805
.
V
SELECT
PEAK-RMS C CREST
Hz
R REC SELECT
1
L3
L1
COM
CAT III
1000V
CAT IV
600V
+
L2
+ +
MAX 1000A
1000V CAT III
600V CAT IV
W
Hz
+
A
Hz
+
A
EF
Hz
+
V
OFF
HOLD
H
ZERO
VFD
AUTO 6002
.
Hz
Hz
PEAK-RMS C CREST
Hz
Hz
R REC SELECT
L3
L1
COM
CAT III
1000V
CAT IV
600V
1
+
L2
+
Note : ACV (and hence AC+DCV & Line-level Hz ) function is equipped with digital low-pass filter, and is capable of dealing with
VFD (Variable Frequency Drive) signals. It also improves ACV reading stability in noisy electrical environments.
13
®
Electric Field EF-Detection
The meter displays “ EF ” when it is ready. Signal strength is indicated as a series of bar-graph segments on the display together with variable beep tones.
+
MAX 1000A
1000V CAT III
600V CAT IV
W
Hz
+
A
Hz
+
A
EF
Hz
+
V OFF eF
ZERO
SELECT
PEAK-RMS
R REC
SELECT
C CREST
Hz
L1
COM
CAT III
1000V
CAT IV
600V
+
L2
+ +
MAX 1000A
1000V CAT III
600V CAT IV
Hz
W
+
A
Hz
+
A
EF
Hz
+
V OFF
HOLD
H
ZERO
–––
PEAK-RMS
R REC
SELECT
C CREST
Hz
L3
L1
COM
CAT III
1000V
CAT IV
600V
+
L2
+ +
MAX 1000A
1000V CAT III
600V CAT IV
W
Hz
+
A
Hz
+
A
EF
Hz
+
V OFF
ZERO
HOLD
H
––––
PEAK-RMS
R REC
SELECT
C CREST
Hz
L1
COM
L3
CAT III
1000V
CAT IV
600V
+
L2
+ +
MAX 1000A
1000V CAT III
600V CAT IV
Hz
W
+
A
Hz
+
A
EF
Hz
+
V OFF
HOLD
H
ZERO eF
PEAK-RMS
R REC
SELECT
C CREST
Hz
L3
L1
COM
CAT III
1000V
CAT IV
600V
+
L2
+
Live Ground v An antenna is located along the top-right end of the stationary clamp jaw, which detects electric field that surround energized conductors. It is ideal for tracing live wiring connections, locating wiring breakage and to distinguish between live or earth connections.
v For more precise indication of live wires, such as distinguishing between Live and Ground connections, use one single probe to test via terminal COM for direct contact EF-Detection with best sensitivity.
14
®
CAUTION & WARNING for Non-Invasive (Clamp-on) Current
Measurements :
CAUTION :
(Application and Removal of the Clamp-on Jaws) For non-invasive current measurements, press the jaw trigger and clamp the jaws around conductor(s) of only one single pole of a circuit for load current measurement. Make sure the jaws are completely closed, or else it will introduce measurement errors. Enclosing conductor(s) of more than one pole of a circuit may result in differential current (like identifying leakage current) measurement. Align the conductor(s) to
TM the Jaws center indicators (Regular or AmpTip indicators where applicable) as much as possible to get the best measuring accuracy.
For removal, press the jaw trigger and remove the jaws from the conductor(s).
Adjacent current-carrying devices such as transformers, motors and conductor wires may affect measurement accuracy. Keep the jaws away from them as much as possible to minimize influence.
WARNING :
Do not use the meter to measure currents above the rated frequency
(400Hz). Circulating currents may cause the magnetic circuits of the
Jaws reach a hazardous temperature.
15
®
ACA, DCA, DC+ACA, & Hz :
Input is made via the clamp jaws with best accuracy specified near the jaw tip area for small conductors low-current measurements.
Press SELECT button momentarily to select the subject functions in sequence. Last selection will be saved as power up default for repeat measurement convenience. Press Hz button momentarily to toggle the Hz function.
+
MAX 1000A
1000V CAT III
600V CAT IV
Hz
W
+
A
Hz
+
A
EF
Hz
+
V
OFF
HOLD
H
ZERO
Hz
+
A
20 i3
.
A
PEAK-RMS
R REC
SELECT
C CREST
Hz
L3
L1
COM
CAT III
1000V
CAT IV
600V
+
L2
+ +
MAX 1000A
1000V CAT III
600V CAT IV
Hz
W
+
A
Hz
SELECT
PEAK-RMS
R REC
+
A
EF
Hz
+
V
OFF
HOLD
H
ZERO i3 i4
.
A
SELECT
C CREST
Hz
1
L3
L1
COM
CAT III
1000V
CAT IV
600V
+
L2
+ +
MAX 1000A
1000V CAT III
600V CAT IV
Hz
W
+
A
+
A
Hz
+
EF
Hz
+
V
OFF
HOLD
H
ZERO
SELECT
+
2403
.
A
C CREST
PEAK-RMS
R REC
SELECT
Hz
L1
COM
CAT III
1000V
CAT IV
600V
+
L2
+ +
MAX 1000A
1000V CAT III
600V CAT IV
Hz
W
+
A
+
A
Hz
R REC
EF
Hz
+
V
OFF
HOLD
H
ZERO
Hz
AUTO 6008
Hz
.
C CREST
PEAK-RMS
Hz
Hz
SELECT
L3
L1
COM
CAT III
1000V
CAT IV
600V
1
+
L2
+
®
Non-Invasive Regular Current Functions :
ACA, DCA, DC+ACA, & Hz :
Input is made via the clamp jaws with best accuracy specified at the jaw center for regular current measurements. Press SELECT button momentarily to select the subject functions in sequence. Last selection will be saved as power up default for repeat measurement convenience. Press Hz button momentarily to toggle the Hz function.
+
MAX 1000A
1000V CAT III
600V CAT IV
W
Hz
+
A
Hz
+
A
EF
Hz
+
V
OFF
HOLD
H
ZERO
AUTO 5380
.
A
Hz
+
A
PEAK-RMS
R REC
SELECT
C CREST
Hz
L3
L1
COM
CAT III
1000V
CAT IV
600V
+
L2
+ +
MAX 1000A
1000V CAT III
600V CAT IV
Hz
W
+
A
Hz
+
A
EF
Hz
+
V
OFF
ZERO
AUTO 3823
.
A
HOLD
H
SELECT
PEAK-RMS
R REC
SELECT
C CREST
Hz
1 L3
L1
COM
CAT III
1000V
CAT IV
600V
+
L2
+ +
MAX 1000A
1000V CAT III
600V CAT IV
+
W
Hz
+
A
Hz
+
A
EF
+
Hz
V
OFF
HOLD
H
ZERO
AUTO
+
5394
.
A
SELECT
PEAK-RMS
R REC
SELECT
C CREST
Hz
L1
COM
CAT III
1000V
CAT IV
600V
+
L2
+ +
MAX 1000A
1000V CAT III
600V CAT IV
Hz
W
+
A
Hz
+
A
EF
+
Hz
V
OFF
HOLD
H
ZERO
AUTO 5998
.
Hz
Hz
R REC
SELECT
C CREST
Hz
L1
COM
L3
1
CAT III
1000V
CAT IV
600V
+
L2
+
16 17
®
Inputs are made through the test lead terminals COM/+ . Press
SELECT button momentarily to select the subject functions in sequence. Last selection will be saved as power up default for repeat measurement convenience.
+ + + + + + + +
MAX 1000A
1000V CAT III
600V CAT IV
Hz
W
+
A
+
W
EF
Hz
+
V OFF
HOLD
H
ZERO
AUTO 3802
.
k W
PEAK-RMS
R
REC
SELECT
C CREST
Hz
L3
L1
COM
CAT III
1000V
CAT IV
600V
+
L2
MAX 1000A
1000V CAT III
600V CAT IV
Hz
W
+
A
Hz
+
A
EF
Hz
+
V OFF
HOLD
H
ZERO
SELECT
PEAK-RMS
R
REC
0005
.
W
SELECT
C CREST
Hz
L1
COM
CAT III
1000V
CAT IV
600V
+
L2
MAX 1000A
1000V CAT III
600V CAT IV
Hz
Hz
W
+
A
+
A
EF
Hz
+
V OFF
HOLD
H
ZERO
.
0602
V
SELECT
PEAK-RMS
R
REC
SELECT
C CREST
Hz
L1
COM
CAT III
1000V
CAT IV
600V
+
L2
MAX 1000A
1000V CAT III
600V CAT IV
Hz
W
+
A
Hz
+
A
EF
Hz
+
V OFF
HOLD
H
ZERO
.
0l
V
PEAK-RMS
R
REC
SELECT
C CREST
Hz
L3
L1
COM
CAT III
1000V
CAT IV
600V
+
L2
Note : When using diode test function, normal forward voltage drop
(forward biased) for a good silicon diode is between 0.400V to
0.900V. A reading higher than that indicates a leaky diode (defective).
A zero reading indicates a shorted diode (defective). An OL indicates an open diode (defective). Reverse the test leads connections
(reverse biased) across the diode. The digital display shows OL if the diode is good. Any other readings indicate the diode is resistive or shorted (defective).
CAUTION :
Using Resistance, Continuity or Diode function in a live circuit will produce false results and may damage the meter. In many cases the suspected component(s) must be disconnected from the circuit to obtain an accurate measurement reading.
18
®
Capacitance, Temperature ºC & ºF functions :
Inputs are made through the test lead terminals COM/+ . Last selection will be saved as power up default for repeat measurement convenience. Press SELECT button momentarily to select the subject functions in sequence.
+
MAX 1000A
1000V CAT III
600V CAT IV
W
Hz
Hz
+
A
+
A
EF
Hz
+
V
OFF
HOLD
H
ZERO
AUTO i536
PEAK-RMS
R REC
SELECT
C CREST
Hz
L3
L1
COM
CAT III
1000V
CAT IV
600V
+
L2
– +
+ + + +
MAX 1000A
1000V CAT III
600V CAT IV
W
Hz
+
A
Hz
+
A
EF
Hz
+
V
OFF
HOLD
H
ZERO
258C
.
SELECT
PEAK-RMS
R REC
SELECT
C CREST
Hz
L1
COM
–
CAT III
1000V
CAT IV
600V +
+
L2
+
+
MAX 1000A
1000V CAT III
600V CAT IV
W
Hz
+
A
Hz
+
A
EF
Hz
+
V
OFF
HOLD
H
ZERO
784F
.
SELECT
PEAK-RMS
R REC
SELECT
C CREST
Hz
L1
COM
–
CAT III
1000V
CAT IV
600V +
+
L2
+
+
+ +
MAX 1000A
1000V CAT III
600V CAT IV
W
A
Hz
+
A
EF
Hz
+
V
OFF
ZERO
HOLD
H
AUTO i3 i4
.
PEAK-RMS
R REC
SELECT
C CREST
Hz
L3
L1
COM
CAT III
1000V
CAT IV
600V
+
L2
+
Note : Be sure to insert the banana plug type-K temperature bead probe Bkp60 with correct + – polarities. You can also use a plug adapter Bkb32 (Optional purchase) with banana pins to type-K socket to adapt other type-K standard mini plug temperature probes.
19
®
CAUTION :
1. Using Capacitance function in a live circuit will produce false results and may damage the meter. In many cases the suspected component(s) must be disconnected from the circuit to obtain an accurate measurement reading.
2. When using Capacitance function, discharge capacitor(s) before making any measurements. Large value capacitors should be discharged through an appropriate resistance load.
Using the Complementary Beeper feature :
The Complementary Beeper feature is selected in Power-up option.
Press and hold the REC button while turning the meter on to enable.
If the segments indicate a clockwise movement, the beeper sounds a single long beep per segment cycle. If the segments indicate a counter clockwise movement, the beeper sounds 3 short beeps per segment cycle.
Hold :
Press the HOLD button momentarily to toggle the hold feature.
Record mode :
Press REC button momentarily to activate MAX/MIN/AVG recording
R MAX MIN AVG ” turn on. The meter beeps when new MAX (maximum) or MIN (minimum) reading is updated. AVG
(Average) reading is calculated over time. Press the button momentarily to read the MAX, MIN and AVG reading in sequence.
Press the button for 1 second or more to exit this mode. Auto-
Power-Off is disabled automatically in this mode.
20
®
Relative-Zero allows the user to offset the meter consecutive measurement with the main display displaying reading as the reference value. LCD “ ?
” turns on. Press the ?
( HOLD ) button for one second or more to toggle Relative-Zero mode.
DC-Zero mode is set instead of Relative-Zero mode, however, to only offset the non-zero DCA residuals caused by magnetic hysteresis of the jaws as in DCA & DC+ACA functions. Press the
?
( HOLD ) button for one second or more to activate/ re-activate this mode. Apply this mode before making any single DCA or DC+
ACA measurement for best measuring accuracy. The meter shows
“ dc_0 ” shortly to confirm activation before continuing measurements. The beeper will sound 3 short beeps, however, to warn for null activation if the residual is beyond a reasonable hysteresis reading of -5 to 5 DCA.
80ms PEAK-RMS mode :
Press PEAK-RMS button for one second or more to toggle PEAK-
RMS mode to capture inrush current or voltage RMS values in disabled automatically in this mode.
5ms CREST mode :
Press CREST button for one second or more to activate CREST mode (Instantaneous PEAK-HOLD) to capture current or voltage
C MAX ” turn on.
The meter beeps when new MAX (maximum) or MIN (minimum) reading is updated. Press the button momentarily to read the MAX and MIN readings in sequence. Press the button for 1 second to exit this mode. Auto-Power-Off is disabled automatically in this mode.
Flashlight & Backlighted LCD display :
Press the button momentarily to toggle the LCD backlight & flashlight ON and OFF. The backlight & flashlight will also be turned off automatically after 32 seconds to extend battery life.
21
®
Intelligent Auto-Power-Off (APO) :
The Auto-Power-Off (APO) mode turn the meter off automatically to extend battery life after approximately 32 minutes of no specified activities, where applicable :
1. Rotary switch or push button operations.
2. Significant measuring readings of above 8.5% of ranges.
3. Non-OL readings for Resistance, Continuity or Diode function.
4. Non-zero readings for Hz function.
5. Significant movement indication as in Phase Rotation functions.
In other words, the meter will intelligently avoid entering the APO mode when it is under normal measurements. To wake up the meter from APO, press the SELECT button momentarily and release, or turn the rotary switch OFF and then back on. Always turn the rotary switch to the OFF position when the meter is not in use.
V. MAINTENANCE :
WARNING :
To avoid electrical shock, disconnect the meter from any circuit, remove the test leads from the input jacks and turn OFF the meter before opening the case. Do not operate with open case.
Trouble Shooting :
If the instrument fails to operate, check batteries and test leads etc., and replace as necessary. Double check operating procedure as described in this manual.
If the instrument voltage-resistance input terminal has subjected to high voltage transient (caused by lightning or switching surge to the system under test) by accident or abnormal conditions of operation, the protective impedance components in series might be blown off
(become high impedance) like open fuses to protect the user and the instrument. Most measuring functions through this terminal might then be open circuit. Such components should only be replaced by qualified technician. Refer to the WARRANTY section for obtaining warranty or repairing service.
22
®
Cleaning and Storage :
Periodically wipe the case with a damp cloth and mild detergent; do not use abrasives or solvents. If the meter is not to be used for periods of longer than 30 days, remove the batteries and store them separately.
Battery replacement :
The meter uses standard 1.5V AA Size (IEC R6) battery X 2.
Loosen the 2 captive screws from the battery cover case. Lift the battery cover case. Replace the batteries. Replace battery cover case. Re-fasten the screws.
–
–
+
AA
23
®
MUMBAI
TEST CERTIFICATE
TRMS DIGITAL CLAMPMETER
This Test Certificate warrantees that the product has been inspected and tested in accordance with the published specifications.
The instrument has been calibrated by using equipment which has already been calibrated to standards traceable to national standards.
SERIAL NO. ___________
DATE: ___________
ISO 9001
REGISTERED
24
QC
KUSAM-MECO
PASS
®
WARRANTY
Each “KUSAM-MECO” product is warranted to be free from defects in material and workmanship under normal use & service. The warranty period is one year (12 months) and begins from the date of despatch of goods. In case any defect occurs in functioning of the instrument, under proper use, within the warranty period, the same will be rectified by us free of charges, provided the to and fro freight charges are borne by you.
This warranty extends only to the original buyer or end-user customer of a “KUSAM-MECO” authorized dealer.
This warranty does not apply for damaged Ic’s, fuses, burnt PCB's, disposable batteries, carrying case, test leads, or to any product which in “KUSAM-MECO’s” opinion, has been misused, altered, neglected, contaminated or damaged by accident or abnormal conditions of operation or handling.
“KUSAM-MECO” authorized dealer shall extend this warranty on new and unused products to end-user customers only but have no authority to extend a greater or different warranty on behalf of “KUSAM-MECO”.
“KUSAM-MECO’s” warranty obligation is limited, at option, free of charge repair, or replacement of a defective product which is returned to a “KUSAM-MECO” authorized service center within the warranty period.
THIS WARRANTY IS BUYER’S SOLE AND EXCLUSIVE REMEDY
AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR
IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE. “KUSAM-MECO” SHALL NOT BE LIABLE
F O R A N Y S P E C I A L , I N D I R E C T, I N C I D E N TA L O R
CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF
DATA, ARISING FROM ANY CAUSE WHATSOEVER.
All transaction are subject to Mumbai Jurisdiction.
25
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement