CDPS-CS6

Auxiliary Control System

DISCLAIMERS

The information in this manual has been carefully checked and is believed to be accurate. Cypress Technology assumes no responsibility for any infringements of patents or other rights of third parties which may result from its use.

Cypress Technology assumes no responsibility for any inaccuracies that may be contained in this document. Cypress also makes no commitment to update or to keep current the information contained in this document.

Cypress Technology reserves the right to make improvements to this document and/or product at any time and without notice.

COPYRIGHT NOTICE

No part of this document may be reproduced, transmitted, transcribed, stored in a retrieval system, or any of its part translated into any language or computer file, in any form or by any means— electronic, mechanical, magnetic, optical, chemical, manual, or otherwise—without express written permission and consent from

Cypress Technology.

© Copyright 2016 by Cypress Technology.

All Rights Reserved.

TRADEMARK ACKNOWLEDGMENTS

All products or service names mentioned in this document may be trademarks of the companies with which they are associated.

SAFETY PRECAUTIONS

Please read all instructions before attempting to unpack, install or operate this equipment and before connecting the power supply.

Please keep the following in mind as you unpack and install this equipment:

• Always follow basic safety precautions to reduce the risk of fire, electrical shock and injury to persons.

• To prevent fire or shock hazard, do not expose the unit to rain, moisture or install this product near water.

• Never spill liquid of any kind on or into this product.

• Never push an object of any kind into this product through any openings or empty slots in the unit, as you may damage parts inside the unit.

• Do not attach the power supply cabling to building surfaces.

• Use only the supplied power supply unit (PSU). Do not use the PSU if it is damaged.

• Do not allow anything to rest on the power cabling or allow any weight to be placed upon it or any person walk on it.

• To protect the unit from overheating, do not block any vents or openings in the unit housing that provide ventilation and allow for sufficient space for air to circulate around the unit.

REVISION HISTORY

VERSION NO.

DATE DD/MM/YY SUMMARY OF CHANGE

RDV1 07/01/16 Preliminary Release

RDV2 21/04/16 Add WebGUI

CONTENTS

1. Introduction ............................................ 1

2. Applications ........................................... 1

3. Package Contents ................................ 1

4. System Requirements ............................ 1

5. Features .................................................. 2

6. Operation Controls and Functions ....... 3

6.1 Front Panel ........................................3

6.2 Rear Panel .........................................4

6.3 IR Pin Definition .................................5

6.4 RS-232/Telnet Command List ..........6

6.5 Software Application .......................8

6.6 Telnet Control ...................................9

6.7 WebGUI Control .............................11

7. Connection Diagram .......................... 17

8. Specifications ...................................... 18

9. Acronyms ............................................. 19

1. INTRODUCTION

The Auxiliary Control System for user utilizing it to cover the devices which would like to be controlled. The benefit for this auxiliary control system makes daily life with more convenience. It comes with eight trigger in which support 4 events to trigger. Moreover, four sets of relay out and IR out to expand control coverage on desired devices. IR

In support IR learning function, device IR signal could be learned for controlling device by remote control. The scheduling function with daylight saving feature to provide the device be performed routinely or at setting time. Comprehensive user control interfaces are available which includes WebGUI, Telnet and console (RS-232 in). Installed with adopt switching hub to offer PoE function which makes more flexibility on installation.

2. APPLICATIONS

• Smart Home Installation

• Even hall/Showroom control

3. PACKAGE CONTENTS

• 1 x Auxiliary Control System

• 1 x IR Receiver

• 1 x IR Blaster

• 1 x Remote Control (CR-157)

• 2 x 5pin Terminal Block

• 4 x 2pin Terminal Block

• 1 x 5V DC Power adaptor

• Operational Manual

4. SYSTEM REQUIREMENTS

Input source equipment such as light, TV, power switch and ….etc. and PC/Laptop.

1

5. FEATURES

• 8 trigger in to active 8 events such as device on/ off and active

• 4 relay control out and IR out to control desired devices such as screen down/up, lighting on/off

• IR In supported IR learner functions

• IR out supported for extend IR signal to further distance allowing control the device installed in far end

• Multi user control interfaces includes WebGUI, Telnet and RS-232 (for unit control)

• Easily setting on WebGUI includes scheduling, trigger and relay setting

• PoE (power over Ethernet) supported

• Easily firmware update via USB file

2

6. OPERATION CONTROLS AND FUNCTIONS

6.1 Front Panel

1

RELAY CONTROL OUT

2 3 4

3 2 1

1

3

IR OUT OUT

IR IN IN

2 1

GND GND

3.3V

GND

INFRARED OUT

2 3 4

1 2

1 RELAY CONTROL OUT 1~4: Connect with control device’s power

± line cable such as A/C sensor, IR sensor, or curtain sensor for control signal sending to activate the control devices.

2 INFRARED OUT 1~4: Connect with IR Blaster, IR Receiver or 3.5mm to D-Sub 9pin adaptor for IR signal transmitting or receiving.

3

6.2 Rear Panel

POWER

DC 5V CONTROL

(POE)

RS485

RS422

RS232

SERVICE

RX+ RXTD-

RXD

TD+ GND

TD+

TD-

GND

TXD GND

5 4 3 2 1

COMPORT

5V

GND 5

1 2 3 4

6 7 8

TRIGGER IN IR IN

1 2 3 4 5 6

4

1 DC 5V: Plug the 5V DC power supply into the unit and connect the adaptor to an AC outlet.

2 CONTROL (POE): Connect with PC/Laptop or intra-net hub for

Telnet/WebGUI control over the devices. If the connected Hub supports PoE function this device may not need to connect with power supply.

3 USB: This slot is reserved for factory firmware update only.

4 COMPORT: These slots are to connect with comport control devices such as RS-232/422/485 with RS baud rate up to 115200.

5 TRIGGER IN: Connect with event device’s signal 5V lines such as window security alarm, door switch, and etc… for trigger signal sending back to Control System.

6 IR IN: Connect with IR Receiver included in the package for IR signal receiving and learning. Send the IR signal that is to be learned by press on the remote control in direct line-of-sight towards the Receiver and use the software to record the IR data into digital format. For software details please refers to section 6.5.

6.3 IR Pin Definition

IR Blaster

1

2

3

Power

IR Blaster Signal

NC

IR Extender

IR Signal

Power

Grounding

IR Learner

1

2

3

IR Signal

Power

Grounding

Note: Due to both IR Extender and IR Learner cables are with similar outlook, a part no. "CBL-IR10C3SA200A sticker has been placed to differentiate the difference on IR Learner.

5

6.4 RS-232/Telnet Command List

Command Name Description

IPCONFIG

SIPADDR

XXX.XXX.XXX.XXX

SNETMASK

XXX.XXX.XXX.XXX

SGATEWAY

XXX.XXX.XXX.XXX

SIPMODE N

Display The Current IP

Configure

Set Ethernet IP

Address

Set Ethernet

Gateway

Parameter

NONE

XXX=0~255

Set Ethernet Net Mask XXX=0~255

XXX=0~255

Set Ethernet IP Mode N= “STATIC” or “DHCP”

VER

FADEFAULT

ETH_FADEFAULT

REBOOT

HELP ( ?

)

HELP N

RELAY N N1

IREMITE N N1

Show Unit Firmware

Version

ALL Configure Set To

Factory Default

ALL Ethernet

Configure Set To

Factory

System Reboot

NONE

NONE

NONE

NONE

Show Command List NONE

Show Descript Of

Command

Relay Control

N : Command Name

IR Control

N(PORT)= 1~4

N1=OPEN/CLOSE/

TOGGLE

N(Port) = IR1~IR4

N1 = CYP Pronto Data

EX: IREMIT IR1

9333,0-157,AF,14,40,14,18

,14,43,14,1B,14,0-

6

Command Name Description

IRLEARN

COMCONF N1

N2 N3 N4

Driver COMPORT

Config

COMSEND N

MACRO N N1

IR Learning

Command

COM data send

Macro Setting

Parameter

NONE

Note. It Will Return CYP

Pronto Data When Send

IR(30~50KHz) To IR In

N(Mode)=R S485/RS42 2/

RS232

N1=Bitrate (4800, 9600,

19200, 38400, 57600,

115200, 250000, 1000000)

N2=DATA LEN (7, 8)

N3= PARITY (NONE/ODD/

EVEN)\r\n

N4 = STOP BIT (1)

N= Data (1-512

Characters )

N = “RUN” or “STOP”

N1 = 1~16 (Macro ID) or

NONE

EX: MACRO RUN 1 or

MACRO STOP

7

6.5 Software Application

Please download the software from our website with file name CDPS

V2.000 and save it in a directory where you may use it later.

Connect the Control System with an active network system and open the CDPS V2.000 application from the directory in a PC/Laptop. Click on Find Devices on Network and a list of the devices connected within the network system will show up.

Double click on the product name and an InfoFrom will appear to show the products’ detail.

Then user may use the IP Address to find the control device through

Telnet, WebGUI or even RS-232/Hyper Terminal tools.

8

6.6 Telnet Control

To access the Telnet control in Windows 7, click on the 'Start' menu and type "cmd" in the Search field then press enter.

Under Windows XP go to the 'Start' menu and click on "Run", type

"cmd" with then press enter.

Under Mac OS X, go to Go→Applications→Utilities→Terminal

See below for reference.

Once in the command line interface (CLI) type "telnet", then the IP address of the unit and "23", then hit enter.

9

Type "help" to list the available commands.

Note: Commands will not be executed unless followed by a carriage return. Commands are case-insensitive. If the IP is changed then the IP

Address required for Telnet access will also change accordingly.

10

6.7 WebGUI Control

On a PC/Laptop that is connected to an active network system, open a web browser and type device’s IP address (default setting IP:

192.168.1.50 ) on the web address entry bar.

A security page will appear to ask for User and Password, please key in “admin” for both and click Submit to enter. The browser will display device’s Macro Setting, Extension Macro, Command, Network &

System Settings control pages for users to control.

6.7.1 Macro Settings

Click on 'Macro Settings' to execute or rename macro. There are

5 Macros inserted as default setting for testing the control system's functionality. Click on Macro 1~5 to demonstrate the functions:

• Macro 1: Close relay from 1~8 sequentially every 100ms

• Macro 2: Open relay from 1~8 sequentially every 100ms

• Macro 3: Toggles relay from 1~8 sequentially every 100ms

• Macro 4: Send IR signal from 1~8 sequentially every 100ms with LED illuminant on front panel.

• Macro 5: Send out command "Hello World" from COM port 1~2 sequentially every 100ms.

Macro 1~8 works align with Trigger IN 1~8 which means, when a trigger signal is activated the control system will execute the command under Macro Setting.

11

Click on the mark to edit the command settings. Up/down arrows are to move the command up or down and button is to delete the command.

Click on Insert button/Add to insert commands. Command can be set to control the Control System/SysCMD, other devices connected within the same Telnet system/Internet area, RS-232 COM ports, IR and

Relay devices connected through the Relay outputs of Control System with delay time. It is suggested the delay time is >100ms once the setting is confimed, double click on Save Change.

Command set to control the devices within the same telent system or internet area require to set its IP and Port number and it is strongly recommand to set the delay time >500ms in order to secure a successful command sending. Command set to control the Relay devices require to set the Port number. Click on Save Change to confirm the setting.

12

13

6.7.2 Extension Macro

Click on 'Extension Macro' to execute/edit more Macro action up to 8 more.

6.7.3 Command Settings

Click on 'Command Settings' to edit or delete commands up to 128 sets. Insert the command directly in the bottom colum of Command

Edit and name the command on the top colum then click on Save

Changes to store the command.

For IR command Learning, press IR Learn first then press the remote control in direct line-of-sight to the IR Reciever connected from the IRL port within 5 seconds. A comand string will show in the bottom colum.

Click on Save Changes to store the command.

Note: Some command may require to add a carriage return (eg:\r or

\x0D) in the end to allow the system to recognize it as an end of the command.

14

For IR command saving, insert the command on the bottom colum and click on CYP/RAW HEX which indicate the IR command type and click on Save changes to store the command. Under uncertainty of the IR command type click on RAW HEX to ensure a successful command saving.

Command under 128 characters including space can be build up to 128 commands, command over 128 characters and under 512 characters including space can be build up to 32 command in addition with 96 commands of 128 characters under. Click on Save

Change to save the command inserted.

6.7.4 Network Settings

Click on 'Network Settings' to set the device’s IP configuration. Once the changes are saved the system will reset the IP address on device automatically and user will need to re-enter the IP address to continue the WebGUI control.

15

System Settings

Click on 'System Settings' to reset the WebGUI login password and save or download the Macro settings. Reset to Default allows IP and login ID & password to be reset back to factory default.

Note: Please ensure that all commands and settings have been saved before performing Reset as this procedure may restore all settings back to factory default.

16

7. CONNECTION DIAGRAM

PC/Laptop

Security Door

Security Window

IR IN TRIGGER IN

GND

5V

ND

ND

ND TD-

TD-

TXDG

TD+G

TD+G XRX+R

RXD

COMPORT

RS422

RS232

RS485

SERVICE (POE)

CONTROL DC 5V

POWER

Power

Supply

1

RELAY CONTROL OUT

2 3 4

3 2 1

1

IR OUT

IR IN

3

OUT

IN

2 1

GND GND

3.3V

GND

INFRARED OUT

2 3 4

IR Blaster

60°

1m 1m 1m

60°

1.5m

Powered Projector Screen IR Extender

Wireless Router

(With Internet

Connection)

17

8. SPECIFICATIONS

Input Ports

Output ports

Control Interface

IR Frequency

Baud Rate

Power Supply

ESD Protection

Dimensions

Chassis Material

Silkscreen Color

Operating Temperature

Storage Temperature

Relative Humidity

Power Consumption (W)

8 x Trigger in (0~15v) with 4 events triggering

1 x IR (with IR learning supported)

1 x USB (Service only)

4 x IR

4 x Replay Output

1 x COMPORT

1 x CONTROL (With PoE)

30~50kHz

Up to 115200bps

5VDC/2.6A (US/EU standards, CE/FCC/

UL certified)

Human Body model:

±8kV (air-gap discharge)

±4kV (contact discharge)

128mm (W) x 108mm (D) x 25mm (H)/

Jack Excluded

128mm (W) x 118mm (D) x 25mm (H)/

Jack Included

Metal

Black

0˚C~40˚C / 32˚F ~ 104˚F

-20˚C~60˚C / -4˚F ~ 140˚F

20~90% RH (no condensation)

5

18

9. ACRONYMS

ACRONYM COMPLETE TERM

19

CYPRESS TECHNOLOGY CO., LTD

Home page: http://www.cypress.com.tw

MPM-CDPSCS6