CDPS-CS6
Auxiliary Control System
DISCLAIMERS
The information in this manual has been carefully checked and is believed to be accurate. Cypress Technology assumes no responsibility for any infringements of patents or other rights of third parties which may result from its use.
Cypress Technology assumes no responsibility for any inaccuracies that may be contained in this document. Cypress also makes no commitment to update or to keep current the information contained in this document.
Cypress Technology reserves the right to make improvements to this document and/or product at any time and without notice.
COPYRIGHT NOTICE
No part of this document may be reproduced, transmitted, transcribed, stored in a retrieval system, or any of its part translated into any language or computer file, in any form or by any means— electronic, mechanical, magnetic, optical, chemical, manual, or otherwise—without express written permission and consent from
Cypress Technology.
© Copyright 2016 by Cypress Technology.
All Rights Reserved.
TRADEMARK ACKNOWLEDGMENTS
All products or service names mentioned in this document may be trademarks of the companies with which they are associated.
SAFETY PRECAUTIONS
Please read all instructions before attempting to unpack, install or operate this equipment and before connecting the power supply.
Please keep the following in mind as you unpack and install this equipment:
• Always follow basic safety precautions to reduce the risk of fire, electrical shock and injury to persons.
• To prevent fire or shock hazard, do not expose the unit to rain, moisture or install this product near water.
• Never spill liquid of any kind on or into this product.
• Never push an object of any kind into this product through any openings or empty slots in the unit, as you may damage parts inside the unit.
• Do not attach the power supply cabling to building surfaces.
• Use only the supplied power supply unit (PSU). Do not use the PSU if it is damaged.
• Do not allow anything to rest on the power cabling or allow any weight to be placed upon it or any person walk on it.
• To protect the unit from overheating, do not block any vents or openings in the unit housing that provide ventilation and allow for sufficient space for air to circulate around the unit.
REVISION HISTORY
VERSION NO.
DATE DD/MM/YY SUMMARY OF CHANGE
RDV1 07/01/16 Preliminary Release
RDV2 21/04/16 Add WebGUI
CONTENTS
1. Introduction ............................................ 1
2. Applications ........................................... 1
3. Package Contents ................................ 1
4. System Requirements ............................ 1
5. Features .................................................. 2
6. Operation Controls and Functions ....... 3
6.1 Front Panel ........................................3
6.2 Rear Panel .........................................4
6.3 IR Pin Definition .................................5
6.4 RS-232/Telnet Command List ..........6
6.5 Software Application .......................8
6.6 Telnet Control ...................................9
6.7 WebGUI Control .............................11
7. Connection Diagram .......................... 17
8. Specifications ...................................... 18
9. Acronyms ............................................. 19
1. INTRODUCTION
The Auxiliary Control System for user utilizing it to cover the devices which would like to be controlled. The benefit for this auxiliary control system makes daily life with more convenience. It comes with eight trigger in which support 4 events to trigger. Moreover, four sets of relay out and IR out to expand control coverage on desired devices. IR
In support IR learning function, device IR signal could be learned for controlling device by remote control. The scheduling function with daylight saving feature to provide the device be performed routinely or at setting time. Comprehensive user control interfaces are available which includes WebGUI, Telnet and console (RS-232 in). Installed with adopt switching hub to offer PoE function which makes more flexibility on installation.
2. APPLICATIONS
• Smart Home Installation
• Even hall/Showroom control
3. PACKAGE CONTENTS
• 1 x Auxiliary Control System
• 1 x IR Receiver
• 1 x IR Blaster
• 1 x Remote Control (CR-157)
• 2 x 5pin Terminal Block
• 4 x 2pin Terminal Block
• 1 x 5V DC Power adaptor
• Operational Manual
4. SYSTEM REQUIREMENTS
Input source equipment such as light, TV, power switch and ….etc. and PC/Laptop.
1
5. FEATURES
• 8 trigger in to active 8 events such as device on/ off and active
• 4 relay control out and IR out to control desired devices such as screen down/up, lighting on/off
• IR In supported IR learner functions
• IR out supported for extend IR signal to further distance allowing control the device installed in far end
• Multi user control interfaces includes WebGUI, Telnet and RS-232 (for unit control)
• Easily setting on WebGUI includes scheduling, trigger and relay setting
• PoE (power over Ethernet) supported
• Easily firmware update via USB file
2
6. OPERATION CONTROLS AND FUNCTIONS
6.1 Front Panel
1
RELAY CONTROL OUT
2 3 4
3 2 1
1
3
IR OUT OUT
IR IN IN
2 1
GND GND
3.3V
GND
INFRARED OUT
2 3 4
1 2
1 RELAY CONTROL OUT 1~4: Connect with control device’s power
± line cable such as A/C sensor, IR sensor, or curtain sensor for control signal sending to activate the control devices.
2 INFRARED OUT 1~4: Connect with IR Blaster, IR Receiver or 3.5mm to D-Sub 9pin adaptor for IR signal transmitting or receiving.
3
6.2 Rear Panel
POWER
DC 5V CONTROL
(POE)
RS485
RS422
RS232
SERVICE
RX+ RXTD-
RXD
TD+ GND
TD+
TD-
GND
TXD GND
5 4 3 2 1
COMPORT
5V
GND 5
1 2 3 4
6 7 8
TRIGGER IN IR IN
1 2 3 4 5 6
4
1 DC 5V: Plug the 5V DC power supply into the unit and connect the adaptor to an AC outlet.
2 CONTROL (POE): Connect with PC/Laptop or intra-net hub for
Telnet/WebGUI control over the devices. If the connected Hub supports PoE function this device may not need to connect with power supply.
3 USB: This slot is reserved for factory firmware update only.
4 COMPORT: These slots are to connect with comport control devices such as RS-232/422/485 with RS baud rate up to 115200.
5 TRIGGER IN: Connect with event device’s signal 5V lines such as window security alarm, door switch, and etc… for trigger signal sending back to Control System.
6 IR IN: Connect with IR Receiver included in the package for IR signal receiving and learning. Send the IR signal that is to be learned by press on the remote control in direct line-of-sight towards the Receiver and use the software to record the IR data into digital format. For software details please refers to section 6.5.
6.3 IR Pin Definition
IR Blaster
1
2
3
Power
IR Blaster Signal
NC
IR Extender
IR Signal
Power
Grounding
IR Learner
1
2
3
IR Signal
Power
Grounding
Note: Due to both IR Extender and IR Learner cables are with similar outlook, a part no. "CBL-IR10C3SA200A sticker has been placed to differentiate the difference on IR Learner.
5
6.4 RS-232/Telnet Command List
Command Name Description
IPCONFIG
SIPADDR
XXX.XXX.XXX.XXX
SNETMASK
XXX.XXX.XXX.XXX
SGATEWAY
XXX.XXX.XXX.XXX
SIPMODE N
Display The Current IP
Configure
Set Ethernet IP
Address
Set Ethernet
Gateway
Parameter
NONE
XXX=0~255
Set Ethernet Net Mask XXX=0~255
XXX=0~255
Set Ethernet IP Mode N= “STATIC” or “DHCP”
VER
FADEFAULT
ETH_FADEFAULT
REBOOT
HELP ( ?
)
HELP N
RELAY N N1
IREMITE N N1
Show Unit Firmware
Version
ALL Configure Set To
Factory Default
ALL Ethernet
Configure Set To
Factory
System Reboot
NONE
NONE
NONE
NONE
Show Command List NONE
Show Descript Of
Command
Relay Control
N : Command Name
IR Control
N(PORT)= 1~4
N1=OPEN/CLOSE/
TOGGLE
N(Port) = IR1~IR4
N1 = CYP Pronto Data
EX: IREMIT IR1
9333,0-157,AF,14,40,14,18
,14,43,14,1B,14,0-
6
Command Name Description
IRLEARN
COMCONF N1
N2 N3 N4
Driver COMPORT
Config
COMSEND N
MACRO N N1
IR Learning
Command
COM data send
Macro Setting
Parameter
NONE
Note. It Will Return CYP
Pronto Data When Send
IR(30~50KHz) To IR In
N(Mode)=R S485/RS42 2/
RS232
N1=Bitrate (4800, 9600,
19200, 38400, 57600,
115200, 250000, 1000000)
N2=DATA LEN (7, 8)
N3= PARITY (NONE/ODD/
EVEN)\r\n
N4 = STOP BIT (1)
N= Data (1-512
Characters )
N = “RUN” or “STOP”
N1 = 1~16 (Macro ID) or
NONE
EX: MACRO RUN 1 or
MACRO STOP
7
6.5 Software Application
Please download the software from our website with file name CDPS
V2.000 and save it in a directory where you may use it later.
Connect the Control System with an active network system and open the CDPS V2.000 application from the directory in a PC/Laptop. Click on Find Devices on Network and a list of the devices connected within the network system will show up.
Double click on the product name and an InfoFrom will appear to show the products’ detail.
Then user may use the IP Address to find the control device through
Telnet, WebGUI or even RS-232/Hyper Terminal tools.
8
6.6 Telnet Control
To access the Telnet control in Windows 7, click on the 'Start' menu and type "cmd" in the Search field then press enter.
Under Windows XP go to the 'Start' menu and click on "Run", type
"cmd" with then press enter.
Under Mac OS X, go to Go→Applications→Utilities→Terminal
See below for reference.
Once in the command line interface (CLI) type "telnet", then the IP address of the unit and "23", then hit enter.
9
Type "help" to list the available commands.
Note: Commands will not be executed unless followed by a carriage return. Commands are case-insensitive. If the IP is changed then the IP
Address required for Telnet access will also change accordingly.
10
6.7 WebGUI Control
On a PC/Laptop that is connected to an active network system, open a web browser and type device’s IP address (default setting IP:
192.168.1.50 ) on the web address entry bar.
A security page will appear to ask for User and Password, please key in “admin” for both and click Submit to enter. The browser will display device’s Macro Setting, Extension Macro, Command, Network &
System Settings control pages for users to control.
6.7.1 Macro Settings
Click on 'Macro Settings' to execute or rename macro. There are
5 Macros inserted as default setting for testing the control system's functionality. Click on Macro 1~5 to demonstrate the functions:
• Macro 1: Close relay from 1~8 sequentially every 100ms
• Macro 2: Open relay from 1~8 sequentially every 100ms
• Macro 3: Toggles relay from 1~8 sequentially every 100ms
• Macro 4: Send IR signal from 1~8 sequentially every 100ms with LED illuminant on front panel.
• Macro 5: Send out command "Hello World" from COM port 1~2 sequentially every 100ms.
Macro 1~8 works align with Trigger IN 1~8 which means, when a trigger signal is activated the control system will execute the command under Macro Setting.
11
Click on the mark to edit the command settings. Up/down arrows are to move the command up or down and button is to delete the command.
Click on Insert button/Add to insert commands. Command can be set to control the Control System/SysCMD, other devices connected within the same Telnet system/Internet area, RS-232 COM ports, IR and
Relay devices connected through the Relay outputs of Control System with delay time. It is suggested the delay time is >100ms once the setting is confimed, double click on Save Change.
Command set to control the devices within the same telent system or internet area require to set its IP and Port number and it is strongly recommand to set the delay time >500ms in order to secure a successful command sending. Command set to control the Relay devices require to set the Port number. Click on Save Change to confirm the setting.
12
13
6.7.2 Extension Macro
Click on 'Extension Macro' to execute/edit more Macro action up to 8 more.
6.7.3 Command Settings
Click on 'Command Settings' to edit or delete commands up to 128 sets. Insert the command directly in the bottom colum of Command
Edit and name the command on the top colum then click on Save
Changes to store the command.
For IR command Learning, press IR Learn first then press the remote control in direct line-of-sight to the IR Reciever connected from the IRL port within 5 seconds. A comand string will show in the bottom colum.
Click on Save Changes to store the command.
Note: Some command may require to add a carriage return (eg:\r or
\x0D) in the end to allow the system to recognize it as an end of the command.
14
For IR command saving, insert the command on the bottom colum and click on CYP/RAW HEX which indicate the IR command type and click on Save changes to store the command. Under uncertainty of the IR command type click on RAW HEX to ensure a successful command saving.
Command under 128 characters including space can be build up to 128 commands, command over 128 characters and under 512 characters including space can be build up to 32 command in addition with 96 commands of 128 characters under. Click on Save
Change to save the command inserted.
6.7.4 Network Settings
Click on 'Network Settings' to set the device’s IP configuration. Once the changes are saved the system will reset the IP address on device automatically and user will need to re-enter the IP address to continue the WebGUI control.
15
System Settings
Click on 'System Settings' to reset the WebGUI login password and save or download the Macro settings. Reset to Default allows IP and login ID & password to be reset back to factory default.
Note: Please ensure that all commands and settings have been saved before performing Reset as this procedure may restore all settings back to factory default.
16
7. CONNECTION DIAGRAM
PC/Laptop
Security Door
Security Window
IR IN TRIGGER IN
GND
5V
ND
ND
ND TD-
TD-
TXDG
TD+G
TD+G XRX+R
RXD
COMPORT
RS422
RS232
RS485
SERVICE (POE)
CONTROL DC 5V
POWER
Power
Supply
1
RELAY CONTROL OUT
2 3 4
3 2 1
1
IR OUT
IR IN
3
OUT
IN
2 1
GND GND
3.3V
GND
INFRARED OUT
2 3 4
IR Blaster
60°
1m 1m 1m
60°
1.5m
Powered Projector Screen IR Extender
Wireless Router
(With Internet
Connection)
17
8. SPECIFICATIONS
Input Ports
Output ports
Control Interface
IR Frequency
Baud Rate
Power Supply
ESD Protection
Dimensions
Chassis Material
Silkscreen Color
Operating Temperature
Storage Temperature
Relative Humidity
Power Consumption (W)
8 x Trigger in (0~15v) with 4 events triggering
1 x IR (with IR learning supported)
1 x USB (Service only)
4 x IR
4 x Replay Output
1 x COMPORT
1 x CONTROL (With PoE)
30~50kHz
Up to 115200bps
5VDC/2.6A (US/EU standards, CE/FCC/
UL certified)
Human Body model:
±8kV (air-gap discharge)
±4kV (contact discharge)
128mm (W) x 108mm (D) x 25mm (H)/
Jack Excluded
128mm (W) x 118mm (D) x 25mm (H)/
Jack Included
Metal
Black
0˚C~40˚C / 32˚F ~ 104˚F
-20˚C~60˚C / -4˚F ~ 140˚F
20~90% RH (no condensation)
5
18
9. ACRONYMS
ACRONYM COMPLETE TERM
19
CYPRESS TECHNOLOGY CO., LTD
Home page: http://www.cypress.com.tw
MPM-CDPSCS6
advertisement
Related manuals
advertisement
Table of contents
- 5 1. Introduction
- 5 2. Applications
- 5 3. Package Contents
- 5 4. System Requirements
- 6 5. Features
- 7 6. Operation Controls and Functions
- 7 6.1 Front Panel
- 8 6.2 Rear Panel
- 10 6.4 RS-232/Telnet Command List
- 12 6.5 Software Application
- 13 6.6 Telnet Control
- 15 6.7 WebGUI Control
- 21 7. Connection Diagram
- 23 9. Acronyms