Communica PSU CCTV 12VDC 3,5A Quick Start Manual
Add to My manuals2 Pages
Communica PSU CCTV 12VDC 3,5A is a DC UPS (12VDC Battery Backup Unit) that provides 3.5 Amp output. It features cold start capabilities and various protection mechanisms, including overload, overvoltage, and short circuit protection. The unit has a built-in intelligent battery charger and an audible tone for mains failure that can be enabled or disabled. It is suitable for indoor use and must be installed and maintained by a skilled and authorized person.
advertisement
DC UPS (12VDC Battery Backup Unit)
Output: 3.5 Amp
Caution
Read the instructions carefully before installing
Use this equipment only in an indoor application
Mounting, Maintenance and repair must be carried out by a skilled and authorized person
Please make sure mains is off when wiring this unit
Features
Cold Start 15A/115Vac, 30A/230Vac
Overload Protection 115% ‐ 135% of the rated power, Pulsing hiccup shut down, auto
recovery
Overvoltage protection
Short circuit protection, recovery
Low power consumption, high reliability
100% full load burn‐in test
Audible tone for mains fail that can be enabled or disabled through a link
AC Failure
Battery protection circuit build in
Battery charger is intelligent switch mode charging processed by a PIC processor
Wiring to an Alarm Control Panel and Radio
Radio
Alarm Control Panel
Wiring diagram
Link open –
Buzzer activated.
Link joined ‐
Buzzer not activated
AC Fail.
Output + (Positive) for a AC fail condition
When AC is restored goes 0V (Negative)
Positive 12V DC +12V
Negative 12V DC Output (‐12V) Black
Positive 12V DC Output (+12V)
Red
Negative 12V DC 0V DC
Connecting
Before connecting the battery, plug the unit into mains.
Disconnect mains before wiring up the equipment to the unit
The unit will dissipate a small amount of heat so please ensure that the unit is installed in a
place where there is sufficient ventilation.
This unit must not be installed outside as it is not protected against water.
Operation
Audible Tone
Power up
Power failure
Battery cut off
LED Indication
Battery charging
RED
OFF
Battery fully charged OFF
No Mains, battery FLASHING voltage ok
No Mains Battery voltage below 10.5V
Continues beep for 3 seconds
Beeps every 30 seconds
30 seconds WARNING Beep before the unit cuts off the battery voltage
FLASHING
GREEN
ON
ON
OFF
BUZZER For no buzzer
OFF
OFF
ON
ON
Remove link
Remove link
Remove link
Remove link
Warranty
This product carries a one year warranty and is subject to the proper installation procedures and must be installed by a qualified person.
Standards
Complies with EN55022, EN61000‐3‐2, 3, EN55024, SANS IEC 60 950