INSTRUCTION MANUAL
P
ocket-size digital multimeter
Safety information
This meter has been designed according to EN61010-1,
EN61010-2-030,EN61010-2-033, 300V CAT III and pollution2.
Follow all safety and operating instructions to ensure the meter is used safely and is kept in good condition With proper use and care, your digital multimeter will give you years of satisfactory service.
During use
• Never exceed the protection limit indicated in the specifications for each range of measurement.
• Never use the meter to measure voltages that might exceed 300V above earth ground in category III installations
• Always be careful when working with voltages above
60v dc or 30v ac rms. keep fingers behind the probe
barriers while measuring.
• Do not perform resistance measurements on live circuits.
• Inspect test leads and probes for cracks, breaks or crazes in the insulation before using the meter
• If the equipment is used in a manner not specified by manufacturer, the protection provided by equipment may be impaired.
Safety Symbols
Important safety information ,refer to the instruction manual.
Earth(ground) TERMINAL
01
Equipment protected throughout by double insulation.
Fuse must be replaced with ratings specified in the manual.
AC (Alternating Current)
CAT III
DC (Direct Current)
It is applicable to test and measuring circuits connected to the distribution part of the building's low-voltage MAINS installation.
European union directives
CONFORMS TO UL STD. 61010-1, 61010-2-030,
61010-2-033, 61010-031; CERTIFIED TO CSA STD.
C22.2 No.61010-1,61010-2-030, 61010-2-033,
61010-031.
FRONT PANEL
M300C
HIGH SAFETY
DMM
V V A
2
V kΩ
20
V kΩ
200
V kΩ mA
300V
2000kΩ
OFF
CAT III 300V 300V 200mA MAX
3
2
4
1
Maintenance
• Before opening case .always disconnect test leads from all energized circuits.
• For continuous protection against fire. Replace fuse only
with ratings: F 250mA/300V (Quick Acting)
• Never use the meter unless the back cover is in place and
fastened completely.
• Do not use abrasives or solvents on the meter .to clean it use only a damp cloth and mild detergent.
02
1. Range switch
This switch is used to select desired ranges as well as to turn on/off the meter .
2. Function switch switch for selecting functions.
3. LCD display
3 1/2digit.7segment.maximum 1999 counts.
4. Test leads
Red test lead for positive (+) and black test lead for negative (-).
03
General description
This compact digital multimeter is designed to measure AC and DC voltages .DC current .Resistance .
Diode and to perform audible continuity checks with accuracy and easy .
Small and lightweight .with a carrying case and test leads wound on its body. This instrument will provide you years of satisfactory service.
Specification
Accuracy is guaranteed for 1 year .
23°C ±5°C, Less than 75%RH.
DC Voltage
Range
2V
20V
200mV
300V
Resolution
1mV
10mV
100mV
1V
Accuracy
±0.5% of rdg ±1dgt
±0.8% of rdg ±1dgt
±0.8% of rdg ±1dgt
±0.8% of rdg ±1dgt
Overload protection:300V dc or rms ac for all ranges
AC Voltage
Range
200V
300V
Resolution
100mV
1V
Accuracy
±1.2% of rdg ±10dgts
±1.2% of rdg ±10dgts
Overload protection: 300V dc or rms ac for all ranges
Frequency range: 45Hz to 450Hz
Response: average responding .calibrated in rms of a sine wave
04
DC Current
Range
200mA
Resolution
0.1mA
Accuracy
±2.0% of rdg ±2dgts
Overload protection: 250mA/300V fuse
Resistance
Range Resolution
2k Ω
20k Ω
200k Ω
2000k Ω
1 Ω
10 Ω
100 Ω
1k Ω
Accuracy
±1.0% of rdg ±2dgts
±1.0% of rdg ±2dgts
±1.0% of rdg ±2dgts
±1.0% of rdg ±2dgts
Maximum open circuit voltage : 0.65V
overload protection: 250V rms ac for all ranges
Diode test
Range Description
Show the approx. forward voltage drop of the diode.
Overload protection: 250V rms ac
Diode test
Range Description
Built-in buzzer sounds when resistance is less than 50 Ω.
Overload protection: 250V rms ac
05
General characteristics
Maximum voltage between
Terminals and earth ground
Fuse protection
Power supply
Display
Measuring method
Over range indication
Polarity indication
Operating temperature
Storage temperature
Low battery indication
Size
Weight
CAT III 300V
F 250 mA/300V
12V battery .GP -23AX1
LCD .1999 counts .updates 2-3/sec dual-slope integration A/D converter only figure “1” on the display
“ - ” displayed for negative polarity
0°C to 40°C (32°F to 104 °F)
-10°C to 50°C (10°F to 122°F) appears on the display
120x70x18mm approx.110g
Operating instruction
DC Voltage measurement
1. Set the function switch at V position
2. Set the range switch at desired position. If the magnitude of voltage to be measured is unknown beforehand .
set the range switch at the highest position and then reduce until satisfactory reading is obtained.
3. Connect test leads across the source or load being measured. The polarity of red lead connection will be indicated at the same time as the voltage value.
4. When the range switch is set at 300V position. “HV”sign will appear on the display to remind user of high voltage measurement. Special attention should be paid.
06
AC Voltage measurement
1. Set the function switch at V~ position
2. Set the range switch at desired position .measurement
reading can be obtained at 2V and 20V positions, but the accuracy is not guaranteed.
3. Connect test leads across the source or load being measured and read the voltage value on the LCD display.
4. When the range switch is set at 300V position , a “HV” sign
will appear on the display to remind user of high voltage
measurement.
DC Current measurement
1. Set the function switch at A position.
2. Set the range switch at 200mA position .measurement
reading can be obtained at other positions. But the decimal point will be at the incorrect place.
3. Open the circuit in which the current is to be measured.
And connect test leads in series with the circuit.
4. Read current value on the LCD display along with the polarity of red lead connection.
Resistance measurement
1. Set the function switch at Ω position .(note: the polarity of red lead is positive “+”)
2. Set the range switch at desired position
3. Connect test leads across the resistor to be measured
and read LCD display.
4. If the resistor was being measured is connected to a circuit .turn off power and discharges all capacitors before applying test leads.
07
Diode test
1. Set the function switch at Ω position .(note: the polarity of red lead is positive “+”)
2. Set the range switch at position.
3. Connect the red test lead to the anode of the diode to be tested and the black lead to the cathode of the diode.
4. The approx. forward voltage drop of the diode will be displayed in mv.if the connection is reversed. Only figure
“1”will be shown
Audible continuity test
1. Set the function switch at Ω position.
2. Set the range at position.
3. Connect test leads to two points of the circuit to be tested.
if the resistance is less than 50 Ω. Buzzer will sound.
Battery & Fuse Replacement
If the sign appears on the LCD display .it indicates that the battery should be replaced. Remove the screw on the back cover and open the case .replace the exhausted battery with a new one of the same type.
Fuse rarely need replacement and blow almost always as a result of operator's error. open the case and replace the blown fuse with the ratings specified: F 250 mA/300V.
WARNING
disconnected from the measured circuit before removing the rear cover. Make sure the rear cover is tightly screwed before using the instrument.
Replacing test leads
Replace test leads if leads become damaged or worn.
WARNING
If the test leads need to be replaced, you must use a new one which should meet EN 61010-031 standard, rated CAT III 300V, 0.4A or better.
Warning
Before attempting to open the case .always be sure that test
leads have been disconnected form measurement circuits.
close case and tighten screws completely before using the
meter to avoid electrical shock hazard.
Accessories
Battery 1pcs (12V GP-23A)
Carrying Case 1pcs
Operating manual 1pcs
MGL EUMAN , S.L.
Parque Empresarial de Argame,
C/Picu Castiellu, Parcelas i-1 a i4
E-33163 Argame, Morcín
Asturias, España, (Spain)
08
00-05-4065
C-LOGIC
55
MANUAL DE INSTRUCCIONES
Multímetro digital compacto
Información de seguridad importante, referido al manual de instrucciones
Terminal de tierra (Ground)
01
Equip o protegido con doble aislamiento .
El fusible debe ser cambiado siguiendo los valores nominales especificados en el manual .
AC ( corriente alterna )
CAT III
DC ( corriente directa/continua )
Es aplicable a los circuitos de prueba y medición conectados a la parte de distribución de la instalación de red de baja tensión del edificio .
Directivas de la unión europea
De acuerdo a UL STD. 61010-1, 61010-2-030,
61010-2-033, 61010-031; CERTIFIED TO CSA STD.
C22.2 No.61010-1,61010-2-030, 61010-2-033,
61010-031.
PANEL FRONTAL
M300C
HIGH SAFETY
DMM
V V A
2
V kΩ
20
V kΩ
200
V kΩ mA
300V
2000kΩ
OFF
CAT III 300V 300V 200mA MAX
3
2
4
1
02 03
Rang o Resolu c i ó n
2V
20V
200mV
300V
1mV
10mV
100mV
1V
Precisión
±0.5%
±0.8%
±0.8%
±0.8% de de de de
rdg ±1dgt
rdg ±1dgt
rdg ±1dgt
rdg ±1dgt
Protección sobrecarga : 300V DC o rms AC para todos los rangos
Tensión AC
Rang
200V
300V o Resolu
100mV
1V c i ó n Precisión
±1.2% de rdg ±10dgts
±1.2% de rdg ±10dgts
Protección sobrecarga : 300V DC o rms AC para todos los rangos
Rango de frecuencia : 45Hz a 450Hz
Respuesta: respuesta promedio .calibrado en rms a sine wave
04
Corriente DC
Rang o
200mA
Resolu
0.1mA
c i
ó n
Precisión
±2.0% de
rdg ±2dgts
Protección sobrecarga
: fusible
250mA/300V
Resist e nc ia
Rang o
2k Ω
20k Ω
200k Ω
2000k Ω
Resolu c i
ó n
1 Ω
10
100
1k
Ω
Ω
Ω
Precisión
±1.0% de
rdg ±2dgts
±1.0% de
rdg ±2dgts
±1.0% de
rdg ±2dgts
±1.0% de
rdg ±2dgts
Tensión máxima con circuito abierto
: 0.65V
Protección sobrecarga
: 250V rms
AC para todos los rangos
Prueba diodo
Rang o
Descrip c i
ó n
Muestra aprox. la caída de tensión directa del diodo
.
Protección sobrecarga: 250V rms AC
Prueba diodo
Rango Descripción
Sonidos de timbre integrados cuando la resistencia es inferior a 50 Ω.
Protección sobrecarga: 250V rms AC
Características generales
Voltaje máximo entre terminales y tierra
Protección de fusibles
Fuente de alimentación
Pantalla
Método de medición
Indicación de sobre rango
Indicación de polaridad
Temperatura de funcionamiento
Temperatura de almacenamiento
Indicación de batería baja
Tamaño
Peso
CAT III 300V
F 250 mA/300V
Batería
12V.GP -23AX1
LCD .1999 cu e nt a s.
Refresh
2-3/sec convertidor A / D de integración de doble pendiente sólo figura "1" en la pantalla
Se muestra "-" para polaridad negativa
0°C a
40°C (32°F a
104 °F)
-10°C a
50°C (10°F a
122°F) aparece en la pantalla
120x70x18mm approx.110g
Instrucción de funcionamiento
Medición de tensión CC
Medición de tensión AC
Medición de corriente DC
Medición de la resistencia
05 06 07
Prueba diodo Reemplazo de cables de prueba
Reemplace los cables de prueba si los cables se dañan o desgastan.
ADVERTENCIA
Si es necesario reemplazar los cables de prueba, debe usar uno nuevo que cumpla con la norma EN 61010-031, con clasificación CAT III 300V, 0.4A o mejor.
Prueba audible de continuidad
1.
Fije el selector de función en la posición
Ω .
2.
Fije el rango en la posición
3.
Conecte los cables de prueba a dos puntos del circuito a probar.
Si la resistencia es menor de
50 Ω la sirena sonará
.
Reemplazo de batería y fusible
Si el símbolo aparece en la pantalla LCD. Indica que se debe reemplazar la batería. Quite el tornillo de la tapa trasera y abra la carcasa. Reemplace la batería agotada por una nueva del mismo tipo.
El fusible rara vez necesita ser reemplazado y casi siempre se funde como resultado de un error del operador. Abra la caja y reemplace el fusible fundido con los valores nominales especificados: F 250 mA / 300V.
ADVERTENCIA
sondas estén desconectadas del circuito medido antes de trasera esté bien atornillada antes de usar el instrumento.
Advertencia
Antes de intentar abrir la carcasa, asegúrese siempre de que los cables de prueba se hayan desconectado de los circuitos de medición. Cierre la caja y apriete los tornillos completamente antes de usar el medidor para evitar el riesgo de descarga eléctrica.
Acce sorios
Batería
Estuche de transporte
Manual de instrucciones l
1pcs (12V GP-23A)
1pcs
1pcs
MGL EUMAN , S.L.
Parque Empresarial de Argame,
C/Picu Castiellu, Parcelas i-1 a i4
E-33163 Argame, Morcín
Asturias, España, (Spain)
08
00-05-4065