Agilent B1500A
Semiconductor Device
Analyzer
User’s Guide
Agilent Technologies
Notices
© Agilent Technologies, Inc. 2005 - 2010
No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or translation into a foreign language) without prior agreement and written consent from Agilent
Technologies, Inc. as governed by United
States and international copyright laws.
Manual Part Number
B1500-900 0 0
Edition
Edition 1, July 2005
Edition 2, December 2005
Edition 3, April 2006
Edition 4, January 2007
Edition 5, June 2007
Edition 6, November 2007
Edition 7, October 2008
Edition 8, February 2009
Edition 9, June 2009
Edition 10, June 2010
Agilent Technologies, Inc.
5301 Stevens Creek Blvd
Santa Clara, CA 95051 USA
Warranty
The material contained in this document is provided “as is,” and is subject to being changed, without notice, in future editions. Further, to the maximum extent permitted by applicable law, Agilent disclaims all warranties, either express or implied, with regard to this manual and any information contained herein, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. Agilent shall not be liable for errors or for incidental or consequential damages in connection with the furnishing, use, or performance of this document or of any information contained herein. Should
Agilent and the user have a separate written agreement with warranty terms covering the material in this document that conflict with these terms, the warranty terms in the separate agreement shall control.
Technology Licenses
The hardware and/or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license.
Restricted Rights Legend
If software is for use in the performance of a
U.S. Government prime contract or subcontract, Software is delivered and licensed as
“Commercial computer software” as defined in DFAR 252.227-7014 (June 1995), or as a “commercial item” as defined in FAR
2.101(a) or as “Restricted computer software” as defined in FAR 52.227-19 (June
1987) or any equivalent agency regulation or contract clause. Use, duplication or disclosure of Software is subject to Agilent Technologies’ standard commercial license terms, and non-DOD Departments and
Agencies of the U.S. Government will receive no greater than Restricted Rights as defined in FAR 52.227-19(c)(1-2) (June
1987). U.S. Government users will receive no greater than Limited Rights as defined in
FAR 52.227-14 (June 1987) or DFAR
252.227-7015 (b)(2) (November 1995), as applicable in any technical data.
DECLARATION OF CONFORMITY
According to EN ISO/IEC 17050-1:2004
Manufacturer’s Name:
Manufacturer’s Address:
Agilent Technologies Singapore (International) Pte. Ltd.
No. 1 Yishun Ave 7
SINGAPORE 768923
Singapore
Declares under sole responsibility that the product as originally delivered
Product Name:
Model Number:
Product Options:
Semiconductor Device Analyzer
High Power Source/Monitor Unit Module,
Medium Power Source/Monitor Unit Module,
High Resolution Source/Monitor Unit Module,
Multi Frequency Capacitance Measurement Unit Module,
High Voltage Semiconductor Pulse Generator Unit Module,
Waveform Generator/Fast Measurement Unit Module
Agilent B1500A
Agilent B1510A, Agilent B1511A, Agilent B1517A,
Agilent B1520A, Agilent B1525A, Agilent B1530A
This declaration covers all options of the above product(s) complies with the essential requirements of the following applicable European Directives, and carries the CE marking accordingly:
Low Voltage Directive (2006/95/EC)
EMC Directive (2004/108/EC) and conforms with the following product standards
EMC Standard
IEC 61326-1:2005 / EN 61326-1:2006
CISPR 11:2003 / EN55011:1998+A1:1999+A2 :2002
IEC 61000-4-2:2001 /EN 61000-4-2:1995+A1:1998+A2:2001
IEC 61000-4-3:2002+A1:2002/EN 61000-4-3:2002+A1:2002
IEC 61000-4-4:2004 / EN 61000-4-4:2004
IEC 61000-4-5:2001/EN 61000-4-5:1995+A1:2001
IEC 61000-4-6:2003 / EN 61000-4-6:1996+A1:2001
IEC 61000-4-11:2004 / EN 61000-4-11:2004
Canada: ICES/NMB-001:2004
Australia/New Zealand: AS/NZS CISPR 11:2004
Limit
Group 1 Class A
4 kV CD, 8 kV AD
3 V/m / 80 MHz-1 GHz / 1.4-2 GHz, 1 V/m / 2-2.7 GHz
0.5 kV signal lines, 1 kV power lines
0.5 kV line-line, 1 kV line-ground
3 V, 0.15-80 MHz
0 % for 1/0.5 cycle, 0 % for 250/300 cycles,
70 % for 25/30 cycles
Safety IEC 61010-1:2001 / EN 61010-1:2001
Canada: CAN/CSA-C22.2 No. 1010.1-92, C/US
Supplementary Information:
The product was tested in a typical configuration with Agilent Technologies test systems.
This DoC applies to above-listed products placed on the EU market after:
March 20, 2010
Date Toshiyuki Kawaji
QA Manager
Agilent Technologies
For further information, please contact your local Agilent Technologies sales office, agent or distributor, or Agilent Technologies Deutschland GmbH, Herrenberger Straße 130, 71034 Böblingen, Germany.
NOTE
• Herstellerbescheinigung
GEÄUSCHEMISSION
Lpa < 70 dB am Arbeitsplatz normaler Betrieb nach DIN 45635 T. 19
• Manufacturer’s Declaration
ACOUSTIC NOISE EMISSION
Lpa < 70dB operator position normal operation per ISO 7779
This ISM device complies with Canadian ICES-001.
Cet appareil ISM est conforme à la norme NMB-001 du Canada.
NOTE
WARNING
Safety Summary
The following general safety precautions must be observed during all phases of operation, service, and repair of this instrument. Failure to comply with these precautions or with specific warnings elsewhere in this manual may impair the protections provided by the instrument. In addition, it violates safety standards of design, manufacture, and intended use of the instrument. Agilent Technologies, Inc. assumes no liability for customer’s failure to comply with these requirements.
Product manuals may be provided on CD-ROM or in printed form. Printed manuals are an option for many products. Manuals may also be available on the Web. Go to www.agilent.com and type the product model number in the Search field at the top of the page.
Do not use this instrument in any manner not specified by the manufacturer. The protective features of this instrument may be impaired if it is used in a manner not specified in the operation instructions.
This instrument is an INDOOR USE product.
This instrument complies with INSTALLATION CATEGORY II for mains input and
INSTALLATION CATEGORY I for measurement input terminals, and POLLUTION
DEGREE 2 defined in IEC 61010-1.
If an instrument is marked CAT I (IEC Measurement Category I), or it is not marked with a measurement category, its inputs must not be connected to line-voltage mains.
• DANGEROUS PROCEDURE WARNINGS
Warnings, such as example below, shall be complied. Procedures throughout in this manual prevent you from potentially hazard. Their instructions contained in the warnings must be followed.
Hazardous voltage of up to the instrument’s maximum voltage may appear at Force,
Guard, and Sense terminals if Interlock terminal is closed. Open the Interlock terminal when the Force, Guard, and Sense terminals are accessible. Voltage applied to the terminals will be limited up to ±40 V or ±42 V.
• BEFORE APPLYING POWER
Verify that all safety precautions are taken. Make all connections to the instrument before applying power. Note the instrument's external markings described under
• GROUND THE INSTRUMENT
This is Safety Class I instrument. To minimize shock hazard, the instrument chassis and cabinet must be connected to an electrical ground. The power terminal and the power cable must meet International Electrotechnical Commission (IEC) safety standards.
• DO NOT OPERATE IN AN EXPLOSIVE ATMOSPHERE
Do not operate the instrument in the presence of flammable gases or fumes.
Operation of any electrical instrument in such an environment constitutes a definite safety hazard.
• KEEP AWAY FROM LIVE CIRCUITS
Operation personnel must not remove instrument covers. Component replacement and internal adjustments must be made by qualified maintenance personnel. Do not replace components with power cable connected. Under certain conditions, hazardous voltages may exist even with the power cable removed. To avoid injuries, always disconnect power and discharge circuits before touching them.
• DO NOT SERVICE OR ADJUST ALONE
Do not attempt internal service or adjustment unless another person, capable of rendering first aid and resuscitation, is present.
• DO NOT SUBSTITUTE PARTS OR MODIFY INSTRUMENT
Because of the danger of introducing additional hazards, do not install substitute parts or perform any unauthorized modification to the instrument. Return the instrument to a Agilent Technologies Sales and Service Office for services and repair to ensure that safety features are maintained.
• IN CASE OF DAMAGE
Instruments that appear damaged or defective should be made inoperative and secured against unintended operation until they can be repaired by qualified service personnel.
WARNING
CAUTION
Safety Symbols
The general definitions of safety symbols used on equipment or in manuals are listed below.
Direct current.
`
Alternating current.
Protective conductor terminal. For protection against electrical shock in case of a fault.
Used with field wiring terminals to indicate the terminal which must be connected to ground before operating equipment.
>
^
Frame or chassis terminal. A connection to the frame (chassis) of the equipment which normally includes all exposed metal structures.
Grounded terminal which indicates the earth potential.
On supply.
Off supply.
Standby supply. The equipment will be marked with this symbol is not completely disconnected from AC mains when power switch is in the standby position.
In position of a bi-stable push switch.
Out position of a bi-stable push switch.
Hazardous voltage and potential for electrical shock. Do not touch terminals that have this symbol when the equipment is on.
Hot surface. Avoid contact. Surfaces are hot and may cause personal injury if touched.
Instruction manual symbol. The equipment will be marked with this symbol when it is necessary for the user to refer to the instruction manual.
&$7, IEC Measurement Category I
The warning sign denotes a hazard. It calls attention to a procedure, practice, condition or the like, which, if not correctly performed or adhered to, could result in injury or death to personal.
The caution sign denotes a hazard. It calls attention to an operating procedure, practice, condition or the like, which, if not correctly performed or adhered to, could result in damage to or destruction of part or all of the equipment.
Power Supply and Measurement Safety
• Power Supply Safety
This instrument can output high currents and voltages. Make sure that the load or device under test can safely handle the output current and voltage. Also, make sure that the connection leads can safely withstand the expected currents and are insulated for the expected voltages.
The instrument outputs may be connected so as to float relative to earth ground.
Isolation or floating voltage ratings are indicated on the instrument, near the output terminal or the Circuit Common terminal.
• Voltage/Current Measurement Safety
Multimeters and other instruments capable of measuring high voltages and currents are subject to specific safety concerns because of the circuits to which they may be connected. To safely use these instruments, you need to understand the markings on the instrument near the input terminals, which include the
Protection Limits and the IEC Measurement Category.
• Protection Limits
Agilent multimeters and other voltage measurement instruments provide protection circuitry to prevent damage to the instrument and to protect against the danger of electric shock, provided the Protection Limits are not exceeded. To ensure safe operation of the instrument, do not exceed the Protection Limits shown on the input terminals.
• Source/Monitor Terminals
Source/monitor unit, SMU, can simultaneously perform DC voltage or current output and measurement. Typical SMU has the Force, Guard, Sense, and Circuit
Common terminals as shown below. Normally the Force, Guard, and Sense terminals are the same potential. Voltage marked around the terminals indicates the Protection Limits.
Force and Sense must be connected to a terminal of a device under test for the
Kelvin connection which is effective for high current measurement and low resistance measurement. For the non-Kelvin connection to ease the connections, connect Force only. Do not connect Sense. It must be opened.
Guard should be extended to around the device terminal for reducing leakage current caused by a coaxial cable used. Guard must be never connected to anything at the device side.
Circuit Common should be connected to shielding of the coaxial cable used.
The following image is the Kelvin triaxial connector of Agilent B1500A’s HPSMU.
½;¨W ¨O] v¨O½v¶´ +]«] ½;¨W
High Voltage Shock Hazard
Agilent B1500A can force dangerous voltages (±200 V for HPSMU and ±100 V for
MPSMU/HRSMU) at the force, guard, and sense terminals. To prevent electric shock hazard, the following safety precautions must be observed during the use of
Agilent B1500A.
• Use a three-conductor AC power cable to appliance coupler (inlet) and the instrument to an electric ground (safety ground).
• Prepare shielding box which covers interface to a device under test and equipped with interlock circuit that opens when the door is opened.
• Before performing measurement, connect the interlock circuit to the Interlock terminal of this instrument.
• Confirm periodically that the interlock function works normally.
• Before touching the connections of the Force, Guard, and Sense terminals, turn the instrument off and discharge any capacitors of the measurement path. If you do not turn the instrument off, complete “all” of the following items, regardless of any instrument’s settings.
• Terminate measurement by pressing the Stop key, confirm that the
Measurement status indicator is not lit.
• Confirm that the High Voltage indicator is not lit.
• Open the shielding box access door (open the Interlock terminal).
• Discharge any capacitors if the capacitance is connected to an SMU.
• Warn workers in the vicinity of the instrument about hazardous conditions.
Gefahr durch Hochspannung
Von den Geräten Agilent B1500A können Spannungen an den Anschlüssen “Force,
Guard und Sense” von bis zu 200 V ausgehen. Um elektrischem Schlag vorzubeugen, ist bei der Benützung der Geräte Agilent B1500A folgendes zu beachten.
• Verwenden Sie ein dreiphasiges AC-Stromkabel für die Gerätsteckvorrichtung
(Eingang) und schließen Sie das Instrument an eine Erdung an
(Sicherheitserdung).
• Bereiten Sie das Abschirmungsgehäuse vor, dass die Oberfläche eines zu testenden Geräts abdeckt und mit einem Verriegelungsstromkreis ausgestattet ist, der bei geöffneter Tür unterbrochen wird.
• Vor der Messung verbinden Sie den Verriegelungsstromkreis mit dem
Interlock-Anschluss dieses Instruments.
• Prüfen Sie in regelmäßigen Abständen, dass die Verriegelungsfunktion ordnungsgemäß funktioniert.
• Bevor Sie die Verbindungen zu den Anschlüssen Force, Guard und Sense berühren, schalten Sie das Instrument aus und entladen alle Kondensatoren des
Messwegs. Wenn Sie das Instrument nicht ausschalten, führen Sie, unabhängig von den Instrumenteinstellungen, alle folgenden Schritte durch.
• Beenden Sie die Messung, indem Sie auf die Taste “Stop” drücken. Stellen
Sie sicher, dass die Statusanzeige “Measurement” nicht leuchtet.
• Stellen Sie sicher, dass die Anzeige “High Voltage” nicht leuchtet.
• Öffnen Sie die Tür des Abschirmungsgehäuses (öffnen des
Interlock-Anschlusses).
• Entladen Sie alle Kondensatoren, wenn die Kapazität mit einer SMU verbunden ist.
• Warnen Sie Mitarbeiter in der Umgebung des Instruments vor den Gefahren.
Danger de choc dû à une haute tension
Une tension dangereuse (max. ± pour HPSMU; 200 Vdc, max. ± pour MPSMU/
HRSMU; 100 Vdc) émanant du dispositif Agilent B1500A peut être sortie aux bornes de force, d'appareil de protection ou de détection. Les précautions suivantes doivent être obserées contre commotion électrique accidentelle.
• Utilisez un câble d’alimentation CA à trois conducteurs vers le coupleur secteur
(entrée) et branchez l’instrument sur une mise électrique à la terre (prise de terre de sécurité).
• Préparez le boîtier de protection qui couvre l’interface avec le dispositif à tester et équipez-le d’un circuit de sécurité qui s’ouvre lors de l’ouverture d’une porte.
• Avant de procéder aux mesures, connectez le circuit de sécurité à la borne
Interlock de l’instrument.
• Vérifiez régulièrement le bon fonctionnement de la fonction de sécurité.
• Avant de toucher les connexions des bornes Force, Guard et Sense, mettez l’instrument hors tension et déchargez tout condensateur du chemin de mesure.
Si vous ne mettez pas l’instrument hors tension, effectuez « toutes » les opérations ci-dessous, quels que soient les paramètres de l’instrument.
• Terminez les mesures en appuyant sur la touche Stop ; vérifiez que l’indicateur d’état Measurement est éteint.
• Vérifiez que le témoin High Voltage est éteint.
• Ouvrez la trappe d’accès au boîtier de protection (ouvrez la borne Interlock).
• Déchargez les éventuels condensateurs si la capacité est connectée à une unité SMU.
• Informez les personnes travaillant à proximité de l’instrument des conditions.
高電圧感電注意
Agilent B1500A のフォース、ガード、センス端子には、危険電圧が出力されること
があります( HPSMU の場合は最大 ±200 Vdc 、 MPSMU/HRSMU の場合は最大 ±100
Vdc )
• 3 極電源ケーブルを使用して本器を接地してください。
• ドアを開くことによって開放されるインターロック回路を装備し、被測定デバ
イスとのインタフェースを覆うことのできるシールド・ボックスを用意してく
ださい。
• 測定を開始する前にはインターロック回路を本器の Interlock 端子に接続してく
ださい。
• インターロック機能が正常であることを定期的に確認してください。
• Force 、 Guard 、 Sense 端子に繋がる接続部に触れる前には、本器の電源を切断し
てください。また、測定系のキャパシタを放電してください。電源を切らない
場合は、以下の事項を全て実施してください。
• Stop キーを押して Measurement インジケータが消灯したことを確認してくだ
さい。
• 高電圧警告( High Voltage )インジケータが消灯していることを確認してく
ださい。
• シールド・ボックスのドアを開けてください( Interlock 端子を開放してくだ
• キャパシタが SMU に接続されているならば、キャパシタを放電してくださ
い。
• 周囲のほかの作業者に対しても、高電圧危険に対する注意を徹底してください。
Product Stewardship
• Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC
This product complies with the WEEE Directive (2002/96/EC) marking requirements. The affixed label indicates that you must not discard this electrical/ electronic product in domestic household waste.
Product Category: With reference to the equipment types in the WEEE directive
Annex 1, this product is classified as a “Monitoring and Control instrumentation” product.
Do not dispose in domestic household waste.
To return unwanted products, contact your local Agilent office or visit the following website for more information.
www.agilent.com/environment/product/
• LCD Fluorescent Lamp
Certain products sold by Agilent contain a liquid crystal display (LCD); backlighting for the LCD is provided by a fluorescent lamp which contains mercury, and must be managed, recycled, and/or disposed in accordance with all applicable laws, ordinances and regulations.
For information on how to recycle or dispose of the fluorescent lamp contained in your own product, visit the following website.
http://www.agilent.com/environment/mercury.shtml
If you live in the U.S., also visit the following websites.
http://www.lamprecycle.org
http://www.eiae.org
If you have additional questions, please visit the following website.
http://www.agilent.com/go/contactus
• Perchlorate Information
Perchlorate Material - special handling may apply. Visit the following website.
http://www.dtsc.ca.gov/hazardouswaste/perchlorate/
Equipment's real-time clock battery or coin cell battery may contain perchlorate and may require special handling when recycled or disposed of in California.
Precautionary Statement
Agilent B1500A Semiconductor Device Analyzer operates in the Microsoft Windows
XP Professional environment. Agilent B1500A requires Agilent EasyEXPERT software, a specially-designed Windows XP application program.
• About guarantee and support for Agilent B1500A
Agilent Technologies guarantees and supports the performance of Agilent B1500A for the same condition as the preload condition when shipped from the factory.
• About updating Agilent EasyEXPERT and the Windows Update
Agilent Technologies confirms the operation of Agilent EasyEXPERT patch programs and important Windows security patches, and provides recommended update information. Visit Agilent B1500A support site, download the patches, and perform the software update.
• About Windows XP application programs and peripherals (including driver)
Using commercial products on Agilent B1500A is your responsibility. Agilent
Technologies cannot provide compatibility information for commercial products. If problems arise, perform Agilent B1500A system recovery.
• About servicing
Bench repair service is available at your nearest Agilent Technologies service center. Be aware that the B1500A configuration might be updated to the latest one without notice because of support issues.
The internal hard disk drive (HDD) might be initialized during servicing. If peripherals are connected, they will be removed.
When Agilent B1500A is returned, the internal HDD might be initialized.
Peripherals will be returned separately.
• Other notes
• Back up the internal HDD to prevent loss of data by accident or failure.
• Protect Agilent B1500A from computer viruses.
• If you connect Agilent B1500A to the network, take care to protect it from computer virus.
Working in Comfort
To optimize your comfort and productivity, it is important that you set up your work area correctly and use your instrument properly. With that in mind, we have developed some set-up and use recommendations for you to follow based on established ergonomic principles. Improper and prolonged use of keyboards and input devices are among those tasks that have been associated with repetitive strain injury (RSI) to soft tissues in the hands and arms. If you experience discomfort or pain while using the instrument, discontinue use immediately and consult your physician as soon as possible. For more information on RSI you may wish to consult the About Repetitive Strain Injury section.
Please study the recommendations described below. Included there are references to relevant parts of international standards, regulations and guidelines, such as ISO 9241 and the European Community Display Screen Equipment directive. You may also wish to consult your employer’s human resources department or other relevant departments for guidance specific to your company.
About Repetitive Strain Injury
Because your comfort and safety are our primary concern, we strongly recommend that you use the instrument in accordance with established ergonomic principles and recommendations. Scientific literature suggests that there may be a relationship between injury to soft tissues -especially in the hands and arms- and prolonged improper use of keyboards or other equipment requiring repeated motions of the hands and forearms. This literature also suggests that there are many other risk factors that may increase the chance of such injury, commonly called Repetitive Strain
Injury.
What is RSI?
Repetitive Strain Injury (RSI -also known as cumulative trauma disorder or repetitive motion injury) is a type of injury where soft tissues in the body, such as muscles, nerves, or tendons, become irritated or inflamed. RSI has been a reported problem for those who perform repetitive tasks such as assembly line work, meatpacking, sewing, playing musical instruments, and computer work. RSI also has been observed in those who frequently engage in activities such as carpentry, knitting, housework, gardening, tennis, windsurfing and lifting children.
What causes RSI?
The specific causes of RSI have not been established. Nevertheless, the incidence of
RSI has been associated with a variety of risk factors, including:
• Too many uninterrupted repetitions of an activity or motion.
• Performing an activity in an awkward or unnatural posture.
• Maintaining static posture for prolonged periods.
• Failing to take frequent short breaks.
• Other environmental and psychosocial factors.
In addition, there have been reports associating the occurrence of RSI with the use of keyboards, mice, and other input devices. Also, certain medical conditions, such as rheumatoid arthritis, obesity and diabetes, may predispose some people to this type of injury.
What if I experience discomfort?
If you are experiencing any discomfort, seek professional medical advice immediately.
Typically, the earlier a problem is diagnosed and treated, the easier it is to resolve.
Mice and Other Input Devices
Various aspects of using mice and other input devices may increase your risk of discomfort or injury. Observing the following recommendations may reduce that risk.
• Try to keep your hand, wrist, and forearm in a neutral position while using your mouse or other input device.
• If you use your thumb to rotate the ball on a trackball or spaceball, keep it in a relaxed, natural shape, and maintain a neutral posture in your hand, wrist, and forearm.
• Hold the mouse gently by draping your fingers over it. Keep your hand relaxed and fingers loose. Do not grip the mouse tightly.
• It takes very little pressure or force from your fingers to activate the buttons or scroll wheel on your mouse, scrolling mouse, trackball, or other input device.
Using too much force can place unnecessary stress on the tendons and muscles in your hands, wrists, and forearms.
• If you are using a scrolling mouse, be sure to keep your fingers and hand in a relaxed, neutral position when activating the scroll wheel. Also, this type of mouse features software that can minimize the number of mouse movements or button clicks.
• When using a mouse, trackball, or other input device, position it as close to the keyboard as possible, and keep it at the same level as you do not have to stretch while using it.
• Be sure to keep your mouse and trackball clean. Regular removal of accumulated dust and dirt helps ensure proper tracking and reduces unnecessary hand and wrist motions.
NOTE
In This Manual
This manual describes the product overview and installation information of Agilent
Technologies B1500A. This manual consists of the following chapters:
• Chapter 1, “Getting Started”
This chapter describes basic operations of Agilent B1500A.
This chapter describes basic features of Agilent B1500A.
This chapter describes installation, device connection, and maintenance.
This chapter describes specifications of Agilent B1500A.
• Chapter 5, “Accessories and Options”
This chapter describes accessories and options of Agilent B1500A.
To get the latest firmware/software/electronic manuals/support information, visit
Agilent Technologies support site (http://www.home.agilent.com), and click
Oscilloscopes, Analyzers, Meters > Parametric & Device Analyzers, Curve Tracers. You can reach the support site for the Agilent B1500A, B1505A, and EasyEXPERT.
Intel and Celeron are trademarks of Intel Corporation in the U.S. and other countries. Microsoft, Windows, and Windows
Vista are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries.
Contents
Agilent B1500A User’s Guide, Edition 10
Contents
WGFMU - Waveform Generator/Fast Measurement Unit . . . . . . . . . . . . . . . . . . . 2-33
Agilent B1500A User’s Guide, Edition 10
Contents
Capacitance Compensation When Using Switching Matrix . . . . . . . . . . . . . . . . . . . 3-47
Agilent B1500A User’s Guide, Edition 10
Contents
Agilent B1500A User’s Guide, Edition 10
1 Getting Started
NOTE
Getting Started
This chapter describes the basic operations of Agilent B1500A. Before learning the product details, let’s try to use the B1500A briefly. The operations need the
B1500A, power cable, and USB keyboard only (USB mouse and stylus pen are optional). Agilent B1500A also requires Agilent EasyEXPERT software as its graphical user interface.
During the operations, you will not connect device under test. Open all measurement terminal.
This chapter consists of the following sections.
•
•
•
•
“To Use Application Test Mode”
•
•
•
If you use the B1500A at the first time
If this is the first time to turn Agilent B1500 on after the delivery, you need to
perform the initial setup of the B1500. See “Inspection and Installation” on page
3-6. After the initial setup and if no users are added, you can automatically logon as
“Agilent B1500 User” account without password.
1-2 Agilent B1500A User’s Guide, Edition 10
NOTE
NOTE
NOTE
NOTE
Getting Started
To Turn On/Off B1500A
To Turn On/Off B1500A
When turning the B1500A on
Open the measurement terminals at the device side when turning the B1500A on.
Also disconnect the device from the measurement terminals and open the measurement terminals after the test. If you leave the connection with the device, the device may be damaged by unexpected operations or charge-up of measurement cables.
If Start EasyEXPERT button is not displayed
Select All Programs > Start EasyEXPERT from the Start menu. The
Start EasyEXPERT button will be displayed.
Automatic start function
If the automatic start function is on, EasyEXPERT is launched within the B1500A boot up process. If the function is off, EasyEXPERT is not launched and the Start
EasyEXPERT button is displayed.
To turn the automatic start function off, use the Start EasyEXPERT window displayed by the File > Exit menu on the EasyEXPERT main screen. And remove the check from the Option > Auto Start of EasyEXPERT menu.
If EasyEXPERT does not run
Launch “Agilent Connection Expert” by using the icon on Windows taskbar. And check the USB0 connection status displayed in “Instrument I/O on this PC” area.
USB0 connection status display example:
USB0
+ B1500A(USB0::2391::1::0001::0::INSTR)
+ agb1500a
+ UsbDevice1
If “agb1500A” and “UsbDevice1” are not listed, add them by using “Add VISA
Alias” in the right-button-menu on “B1500A (USB0:: . . ::INSTR)”. If the problem still remains, perform Agilent B1500 system recovery. To perform recovery, see
Agilent EasyEXPERT User’s Guide .
Agilent B1500A User’s Guide, Edition 10 1-3
Getting Started
To Turn On/Off B1500A
To Turn B1500A On
1. Connect the power cable from Agilent B1500A to an AC power outlet.
2. Connect the USB keyboard to the B1500A. Optionally, connect the USB mouse to the B1500A.
3. Press the Standby switch (lower right corner of the front panel). Windows, measurement module initialization, and self-calibration will start. For the
Windows logon screen, log on Windows.
After logging on, the Start EasyEXPERT button will be displayed on the screen, or EasyEXPERT will be launched if the automatic start function is on.
To Turn B1500A Off
Press the Standby switch (lower right corner of the front panel). Windows will be shutdown and the B1500A will become the standby state.
1-4 Agilent B1500A User’s Guide, Edition 10
NOTE
Getting Started
To Turn On/Off B1500A
Agilent B1500A has the following front panel user interface.
• Stop
Stops the present measurement or source output immediately.
• Rotary knob
Rotating the knob moves the marker on the graph window, or increases/decreases/changes the value in the active entry field.
Pressing the knob sets or enters the value.
• Softkeys
Seven softkeys are available. Used to select one for the entry field specified or the dialog box. They are also used to recall the test definitions (pre-defined test setups).
• Touch Panel Off
Enables or disables the touch screen operation.
• Standby switch
Turns the B1500A on. Pressing the button in the ON state makes the B1500A in the standby state.
• LCD Off
Enables or disables the LCD panel. LED lights when the LCD is disabled.
• Auto, , +, Menu
Four keys are available for the display adjustment. Press Auto to perform adjustment automatically. Use , +, and Menu to adjust manually.
Agilent B1500A also requires Agilent EasyEXPERT software as its graphical user interface. You can operate Agilent EasyEXPERT by using the touch panel. Use your fingers, stylus pen, and so on for the touch panel operation. The USB keyboard and the USB mouse are also available for operating the EasyEXPERT.
To remove USB devices from the B1500A, use “Safely Remove Hardware” on
Windows taskbar. If it is not used, the B1500A may cause the internal USB communication error. If the error occurs, turn the B1500A off and disconnect the power cable from the B1500A. Leave it about 30 seconds before rebooting the
B1500A, and connect the power cable again, and then turn the B1500A on.
Agilent B1500A User’s Guide, Edition 10 1-5
Getting Started
To Launch EasyEXPERT
To Launch EasyEXPERT
1. If the automatic start function is off, the Start EasyEXPERT button is displayed.
Click the button and wait until the EasyEXPERT main screen or workspace selection screen is displayed.
NOTE Workspace is the space created in Agilent B1500A’s internal hard disk drive, and is used to store the test setup, test result data, and so on. The workspace can be created and allocated for each user.
2. If this is the first time to start the EasyEXPERT, or if no workspace exists, a workspace will be created automatically.
Skip to “To Use Tracer Test Mode” on page 1-10, “To Use Application Test
Mode” on page 1-12, or “To Use Classic Test Mode” on page 1-14.
3. If only one workspace exists, the B1500A displays the screen as shown in Figure
Skip to “If Only One Workspace Exists” on page 1-7.
4. If two or more workspaces exist, the B1500A displays the screen as shown in
Skip to “To Select Workspace” on page 1-9.
1-6 Agilent B1500A User’s Guide, Edition 10
Figure 1-1
Getting Started
To Launch EasyEXPERT
If Only One Workspace Exists
For the screen as shown in Figure 1-1, perform the following steps.
1. If you do not want to create a workspace, select the Yes radio button and click
OK.
Skip to “To Use Tracer Test Mode” on page 1-10, “To Use Application Test
Mode” on page 1-12, or “To Use Classic Test Mode” on page 1-14.
2. If you want to create a workspace, select the No radio button and click Next. The
B1500A displays the screen as shown in Figure 1-2.
Skip to “To Create Workspace” on page 1-8.
If Only One Workspace Exists
NOTE
Work on the same setups and data in the next time
If this check box is checked, the workspace selection screen will be skipped at the next startup and EasyEXPERT will be launched with the workspace used at the last operation. To perform this setup again, click the File > Close Workspace menu on the EasyEXPERT main screen.
Agilent B1500A User’s Guide, Edition 10 1-7
Figure 1-2
Getting Started
To Launch EasyEXPERT
To Create Workspace
For the screen as shown in Figure 1-2, perform the following steps. To cancel
creating workspace, click Prev.
1. Enter the name of the new workspace into the above-entry field.
Check Allow other users to access this workspace box if you want to create a public workspace that is opened for all users.
2. If you are the owner of the existing workspace, you can change the name of the existing workspace.
If you want to rename the existing workspace, enter the name into the below-entry field.
Check Allow other users to access this workspace box if you want to set it to a public workspace that is opened for all users.
3. Click OK.
Skip to “To Use Tracer Test Mode” on page 1-10, “To Use Application Test Mode”
on page 1-12, or “To Use Classic Test Mode” on page 1-14.
To Create Workspace
1-8 Agilent B1500A User’s Guide, Edition 10
Figure 1-3
Getting Started
To Launch EasyEXPERT
To Select Workspace
For the screen as shown in Figure 1-3, perform the following steps. This example
selects the workspace named as Demo Workspace that is a public workspace that is opened for all users.
1. Select Public Workspaces owned by other users radio button.
2. Click Demo Workspace to select it.
3. Click Continue.
Skip to “To Use Tracer Test Mode” on page 1-10, “To Use Application Test Mode”
on page 1-12, or “To Use Classic Test Mode” on page 1-14.
To Select Workspace
NOTE
Choose the same Workspace in the next time
If this check box is checked, the workspace selection screen will be skipped at the next startup and EasyEXPERT will be launched with the workspace used at the last operation. To perform this setup again, click the File > Close Workspace menu on the EasyEXPERT main screen.
Agilent B1500A User’s Guide, Edition 10 1-9
Table 1-1
Table 1-2
Getting Started
To Use Tracer Test Mode
To Use Tracer Test Mode
The following procedure performs the tracer test setup.
1. Click the Tracer Test tab on the main screen. The tab is in the leftmost column
on the screen. The I/V Trace screen is displayed. See Figure 1-4.
2. Set the channels at the field below the graph as shown in Table 1-1.
3. Set the measurement condition at the right field of the graph as shown in Table
4. Set the graph display condition at the field below the graph as shown in Table
To enter the value, use the USB keyboard or the screen/numeric keyboard opened by clicking the right button of the entry field.
To start measurement, click for the repeat measurement.
for the single measurement or
If the Stop field is highlighted, the range of measurement and graph display can be changed by using the rotary knob during the repeat measurement.
I/V Trace Channel Setup
Unit V Name I Name Mode a Function
SMU1 V1 I1 V VAR1
SMU2 V2 I2 V CONST a. Channel output mode. Set I or IPULSE for the current output and voltage measurement. Set V or VPULSE for the voltage output and current measurement.
I/V Trace Graph Setup
Name
Y I1 LIN
Scale
X
Name
V1 LIN
Scale
1-10 Agilent B1500A User’s Guide, Edition 10
Table 1-3
Figure 1-4
Getting Started
To Use Tracer Test Mode
I/V Trace Measurement Setup
Mode
Start
Stop
Step
NOS
Interlacing
Compliance
Pwr Comp.
Dual Polarity
VAR1
LIN-SGL
0 V
1 V
10 mV
101
1
5 mA
OFF
ON
Display Example of I/V Trace Screen
Unit
Source
Compliance
CONST
SMU2
0 V
5 mA
Meas. Time
Step Time
2 us
500 us
Agilent B1500A User’s Guide, Edition 10 1-11
Figure 1-5
Getting Started
To Use Application Test Mode
To Use Application Test Mode
For the screen as shown in Figure 1-5, perform the following procedure.
Display Example of EasyEXPERT Main Screen
1. Click the Application Test tab on the main screen. The tab is in the leftmost column on the screen.
2. Set the Category field. For example, check the CMOS only. The Library field lists the test definitions.
3. Select a test definition at the Library field. For example, click the Id-Vg and
Select
button sequentially. The screen changes the display as shown in Figure
4. Change the measurement conditions at the Test Parameters field.
The following example changes the voltage sweep output.
a. Set VgStart to 0 V and VgStep to 0.2 V .
b. Set VsubsStep to -1.0 V .
1-12 Agilent B1500A User’s Guide, Edition 10
NOTE
Figure 1-6
Getting Started
To Use Application Test Mode
To enter the value, use the USB keyboard or the screen/numeric keyboard opened by clicking the right button of the entry field.
See “To Perform Measurement” on page 1-16 to start measurement.
Test Definitions
Test definitions are the built-in test setups that have been defined and stored in the
EasyEXPERT as the application library. The EasyEXPERT contains more than two hundred test definitions. You can execute the test without modifications. Also you can create your own test setup/definition by making any changes. All furnished test definitions are just sample. Agilent Technologies is NOT LIABLE for any damages caused by the samples.
Display Example of Application Test Setup Screen
Agilent B1500A User’s Guide, Edition 10 1-13
Figure 1-7
Getting Started
To Use Classic Test Mode
To Use Classic Test Mode
The following procedure performs the I/V Sweep classic test setup.
1. Click the Classic Test tab on the main screen. The tab is in the leftmost column on the screen.
2. Click I/V Sweep and Select button sequentially. The I/V Sweep Channel Setup
screen is displayed. See Figure 1-7.
3. Set the Channel Setup parameters as shown in Table 1-4.
4. Click the Measurement Setup tab and set the parameters as shown in Table 1-5.
5. Click the Display Setup tab and set the parameters as shown in Table 1-6.
To enter the value, use the USB keyboard or the screen/numeric keyboard opened by clicking the right button of the entry field.
Display Example of I/V Sweep Channel Setup Screen
1-14 Agilent B1500A User’s Guide, Edition 10
Table 1-4
Table 1-5
Table 1-6
Getting Started
To Use Classic Test Mode
See “To Perform Measurement” on page 1-16 to start measurement.
I/V Sweep Channel Setup
Unit V Name I Name Mode a Function
SMU1 V1 I1 V VAR1
SMU2 V2 I2 V CONST a. Channel output mode. Set I or IPULSE for the current output and voltage measurement. Set V , VPULSE , or COMMON for the voltage output and current measurement.
I/V Sweep Measurement Setup
VAR1
Unit SMU1
Name V1
Direction Single
Linear/Log LINEAR
Start
Stop
0 V
1 V
10 mV Step
No of Step 101
Compliance 100 mA
Pwr Comp OFF
Hold
Delay
Sweep
Timing
0 s
0 s
CONTINUE AT ANY
Constants
Unit
V Name
I Name
Mode
SMU2
V2
I2
V
Source 0 V
Compliance 100 mA status
I/V Sweep Display Setup
X
Y1
V1
I1
Name Sharing
(None)
(None)
Scale
Linear
Linear
Min
0 V
-1 pA
1 V
Max
1 pA
Agilent B1500A User’s Guide, Edition 10 1-15
Figure 1-8
Getting Started
To Perform Measurement
To Perform Measurement
1. Click the Single button (upper right on the main screen) to start measurement.
This opens the Data Display window and starts a single sweep measurement.
After the measurement, the measurement data is displayed on the Data Display
window. For the measurement after performing “To Use Classic Test Mode” on
page 1-14, you will have the test result as shown in Figure 1-8. This is the
leakage current measurement result because all measurement terminal is opened for performing the procedures described in this chapter.
2. If the automatic data record function has been set to ON (Auto Record ON), Test
Result Editor appears on the lower area of the screen when the measurement is
completed. See “To Use Test Result Editor” on page 1-17.
Display Example of Data Display Window
1-16 Agilent B1500A User’s Guide, Edition 10
Getting Started
To Perform Measurement
To Use Test Result Editor
The Test Result Editor provides the following GUI to set a flag and remarks to the test result record.
• Save button and Delete button
Divides test records into groups, Save and Delete.
Test records in Save-group are always listed in the lower area of the
EasyEXPERT main screen.
Test records in Delete-group can be listed when Results > Filter >
Show Deleted Data is checked.
• Flags buttons
The following buttons are available. You can set one of the following flags.
• Important ! button
Sets the important flag (!) to the test result record.
• Valid # button
Sets the valid flag (#) to the test result record.
• Questionable ? button
Sets the questionable flag (?) to the test result record.
• Remarks field
You can enter characters into this field. The characters will be recorded as the
Remarks value of the test result record.
• OK button
Applies the setup on the Test Result Editor, and closes this dialog box.
Agilent B1500A User’s Guide, Edition 10 1-17
Figure 1-9
Getting Started
To Use Analysis Tools
To Use Analysis Tools
The Data Display window provides several analysis functions.
• View menu: used to adjust the graph scale.
• Marker menu: used to display and control the marker.
• Cursor menu: used to display and control the cursor.
• Line menu: used to display and control the lines.
When the marker, cursor, and lines are effective, their parameters are also displayed on the X-Y Graph Plot area.
Figure 1-9 is an example displaying marker, tangent line, and regression line on the
test result graph shown in Figure 1-8. You can read position of the marker and the
active cursor, and interrupt and gradient of the active line.
Display Example of Analysis Tools
1-18 Agilent B1500A User’s Guide, Edition 10
2 Introduction
NOTE
NOTE
Introduction
This chapter describes the basic functions and features of Agilent B1500A
Semiconductor Device Analyzer, and consists of the following sections:
•
•
•
•
Application Library
Agilent B1500A has installed Agilent EasyEXPERT software as the user interface.
The EasyEXPERT contains an application library that is a set of test definitions. The application test can be performed by selecting a test definition and setting the test condition for the actual DUT (device under test).
All test definitions are just sample. If the samples damage your devices, Agilent
Technologies is NOT LIABLE for the damage.
Utility
The following utility programs (sample) are stored in the folder C:\Program
Files\Agilent\B1500\EasyEXPERT\Utilities.
• Prober control programs
• 4155/4156 setup file converter
• sleep.exe program
For more details, see Agilent EasyEXPERT User’s Guide.
2- 2 Agilent B1500A User’s Guide, Edition 10
Introduction
Overview
Overview
Agilent B1500A Semiconductor Device Analyzer is the new generation one box solution for the semiconductor device DC/AC parametric measurement and analysis application. Agilent B1500A provides the DC voltage/current output capability, DC voltage/current measurement capability, and AC signal output and impedance measurement capability. So you can perform a current-voltage sweep measurement and a capacitance-voltage sweep measurement for example by one instrument.
Agilent B1500A also provides an intuitive graphical user interface, touch screen
LCD panel, keyboard, and mouse for easy and effective measurement and analysis on the Microsoft
Windows
environment. You can analyze a measurement result characteristics graph for example by using several tools such as markers, cursors, and lines.
Also, in the GPIB remote control mode, you can control the B1500A from an external computer by using Agilent FLEX command set that is the common language for Agilent semiconductor DC measurement instruments. So you can reuse the measurement program created for Agilent 4155/4156/E5260/E5270.
Agilent B1500A User’s Guide, Edition 10 2- 3
Introduction
Overview
• Agilent B1500A Semiconductor Device Analyzer
Mainframe that provides the ground unit (GNDU) and ten empty slots for the measurement facilities, and Agilent EasyEXPERT software for the operating environment. The EasyEXPERT is the GUI based measurement control and analysis software runs on the Windows
XP Professional.
The B1500A is equipped with the 15 inch LCD with touch panel, hard disk drive, DVD-ROM/CD-ROM/CD-RW drive, and USB/LAN/GP-IB interfaces.
The USB keyboard, the USB mouse, and the stylus pen are available as option.
• HPSMU module
High power source/monitor unit module. Occupies two slots.
• MPSMU module
Medium power source/monitor unit module. Occupies one slot.
• HRSMU module
High resolution source/monitor unit module. Occupies one slot. Needs Agilent
E5288A ASU to perform atto level current measurement or automatic switching of the measurement resource connection.
• MFCMU module
Multi frequency capacitance measurement unit module. Occupies one slot.
Needs Agilent N1301A-100 SCUU to perform automatic switching of the measurement resource connection.
• SPGU module
High voltage semiconductor pulse generator unit module. Occupies one slot. Up to five modules can be installed in one B1500A mainframe. One module provides two output channels. Needs Agilent 16440A (B1500A-A04) and
16445A to perform automatic switching of the measurement resource connection.
• WGFMU module and RSU
Waveform generator/fast measurement unit module and the remote-sense and switch unit. Occupies one slot. Up to five modules can be installed in one
B1500A mainframe. One module provides two channels. See Agilent B1530A
User’s Guide for using the WGFMU.
2- 4 Agilent B1500A User’s Guide, Edition 10
Introduction
Overview
• Agilent 16440A SMU/PGU pulse generator selector (B1500A-A04)
Used to switch the measurement resource connected to the DUT. The measurement resource can be SPGU or SMU. Needs the 16445A adapter to use the selector. One selector provides two switching channels.
• Agilent 16442B test fixture (B1500A-A5F)
Test fixture for semiconductor parameter analyzers and device analyzers.
Provides three Kelvin triaxial connectors (six non-Kelvin triaxial connectors) for connecting SMU, six BNC connectors for connecting SPGU, MFCMU, or other instruments, a GNDU connector, and an Intlk connector. Furnished with the dual-in-line package socket module, universal socket modules (two types), blank Teflon board, and connection wires for device connection.
• Agilent 16445A selector adapter
Used to connect the 16440A selector (B1500A-A04) to the B1500A. Two selectors can be connected.
• Agilent E5288A ASU
Atto sense and switch unit (ASU). Used to enable the 1 pA range for the atto level current measurement, also switch the measurement resource connected to the DUT. The measurement resource can be HRSMU or the instrument connected to the AUX terminal.
• Agilent N1301A-100 SCUU
SMU CMU unify unit (SCUU). Used to switch the measurement resource connected to the DUT. The measurement resource can be CMU or one of two
SMUs connected to the SCUU.
• Agilent N1301A-200 GSWU
Guard switch unit (GSWU). Needs the SCUU to use the GSWU. Effective for the accurate impedance measurements by connecting the guard lines between
CMU high and low near the DUT.
Agilent B1500A User’s Guide, Edition 10 2- 5
Introduction
Overview
Application Test
Agilent EasyEXPERT Software
Agilent EasyEXPERT software is a specially-designed Windows
XP application program for controlling Agilent B1500A. The EasyEXPERT provides the easy and effective measurement and analysis environment with intuitive graphical user interface (GUI), touch screen LCD panel, keyboard, and mouse. Some of the functions are listed below.
• Single measurement, repeat measurement, and append measurement
• Switching matrix control
Supported models:
• Agilent B2200A/B2201A switching matrix
• Agilent E5250A switching matrix with E5252A (EasyEXPERT Plus edition)
• Measurement/setup data management by workspace
• Graph display and analysis with markers, cursors, and lines; and auto analysis
• Data import/export capability, data output by CSV/XML format, and graph output by EMF/BMP/GIF/PNG format
• Maintenance; self-test and self-calibration
The EasyEXPERT has the following measurement execution environments.
• Application test
• Classic test
• Tracer test
• Quick test
The EasyEXPERT contains an application library that supports typical measurements for CMOS devices, TFT, BJT, memory, nanotechnology devices such as CNT FET, and so on. The application library includes more than two hundred test definitions.
You can perform measurements by choosing the best one for your device under test
(DUT) from the application libraries, and modifying and executing it. Modification is really simple. For example, it will be completed by changing the output voltage only to DUT terminals. And the setup with your modifications can be saved and recalled as your setup ( My Favorite Setup ).
2- 6 Agilent B1500A User’s Guide, Edition 10
Classic Test
Tracer Test
Quick Test
Introduction
Overview
You can perform measurements by using the user interface similar to the semiconductor parameter analyzers such as Agilent 4156C. The setup can be made by entering values into the setup tables used for the measurement module control.
And it can be saved and recalled as your setup ( My Favorite Setup ). This measurement environment provides the following functions.
• I/V Sweep
• Multi Channel I/V Sweep
• I/V List Sweep
• I/V-t Sampling
• C-V Sweep
• SPGU Control
• Switching Matrix Control
• Direct Control
The Direct Control test mode is used to control the measurement modules directly by using the B1500A GPIB control commands and perform measurement. For the control commands, see “Programming Guide”.
Curve tracer test mode. This test allows you to perform the high speed I-V measurement on one screen. The Tracer Test screen provides GUI for selecting the used channels, setting the sweep output, and displaying the measurement result
(tracing the I-V curve). Range of the sweep output and measurement can be changed by the rotary knob on the front panel.
You can execute the test setups saved in a preset group ( My Favorite Setup ) sequentially.
Agilent B1500A User’s Guide, Edition 10 2- 7
NOTE
Introduction
Front View
Front View
This section describes the front view of Agilent B1500A.
6
5
11
4 1
12
3 2
1. Standby switch
Turns the B1500A on. Pressing the button in the ON state makes the B1500A in the standby state. The green LED lights when the B1500A is in the ON state.
When turning the B1500A on
Open the measurement terminals at the device side when turning the B1500A on.
Also disconnect the device from the measurement terminals and open the measurement terminals after the measurement. If you leave the connection with the device, the device may be damaged by unexpected operations or charge-up of measurement cables.
2. HDD access indicator
This green LED lights in the access status of HDD or DVD-ROM/CD-ROM/
CD-RW drive. Do not turn the B1500A off during this LED lights.
2- 8 Agilent B1500A User’s Guide, Edition 10
7
8
9
10
NOTE
Introduction
Front View
3. OSD buttons
LCD Off enables or disables the LCD panel. The green LED lights when the
LCD is disabled.
Four keys are available for the display adjustment. Press Auto to perform adjustment automatically. Use , +, and Menu to adjust manually.
4. USB interfaces
USB, 2 ports. For keyboard, mouse, and so on. USB keyboard and USB mouse are available as option.
To remove USB devices from the B1500A, use “Safely Remove Hardware” on
Windows taskbar. If it is not used, the B1500A may cause the internal USB communication error. If the error occurs, turn the B1500A off and disconnect the power cable from the B1500A. Leave it about 30 seconds before rebooting the
B1500A, and connect the power cable again, and then turn the B1500A on.
5. LCD panel
15 inch TFT XGA display, 1024 768 resolution. Displays the Windows screen,
Agilent EasyEXPERT software window, and so on. Touch screen operation is available when the Touch Panel Off indicator does not light.
About screen adjustment
If you find swinging or flickering in screen while you use this instrument, perform the screen adjustment. In most cases, the symptoms can be resolved by pressing the
Auto button below the LCD panel. The Auto button is used to start the automatic screen adjustment. Also the manual screen adjustment is available by using the adjustment menu displayed by pressing the Menu button.
6. Stop key
Stops the present measurement or source output immediately.
7. High voltage status indicator
This red LED lights when a source channel applies more than ± 42 V.
8. Measurement status indicator
This green LED lights when a measurement channel performs measurement.
9. Rotary knob
Works on Agilent EasyEXPERT environment. Rotating the knob moves the marker on the graph window, or increases/decreases/changes the value in the active entry field. Pressing the knob sets or enters the value.
Agilent B1500A User’s Guide, Edition 10 2- 9
NOTE
Introduction
Front View
10. Softkeys
Seven softkeys are available for Agilent EasyEXPERT environment. Used to select an alternative for the entry field specified or the dialog box.
11. DVD-ROM/CD-ROM/CD-RW drive
For data backup, B1500A update, or data transfer.
12. Touch Panel Off key
Works on Agilent EasyEXPERT environment. Enables or disables the touch screen operation. The green LED lights when the touch screen is disabled.
To disable the touch panel
Use Touch Panel Device Properties, and remove the check from the Enabled box on the Advanced tab screen. The Touch Panel Device Properties dialog box can be opened by selecting Gunze TPDD > Adjust Settings from Windows program menu.
5
6 7
8
9
10
4
11
1
12
3 2
2- 10 Agilent B1500A User’s Guide, Edition 10
Introduction
Rear View
Rear View
This section describes the rear view of Agilent B1500A.
4
3
2
E
D
D
D
D
D
D
5
1
13 12 11 10 6
C
B
A
9 8 7
1. Serial number
You need this serial number when using Agilent Technologies telephone assistance program.
2. LED status indicator
For troubleshooting. Followings are some examples.
• Both LEDs turn off:
B1500A is in the standby state and Standby switch is OFF position.
• One LED turns green:
Power supply works normally.
• Both LEDs turn orange:
B1500A is in the standby state and Standby switch is ON position.
Agilent B1500A User’s Guide, Edition 10 2- 11
CAUTION
WARNING
Introduction
Rear View
3. LINE input receptacle
AC power cable is connected to this receptacle.
4. GPIB interface
Use an Agilent 82357A USB/GPIB interface or Agilent 10833A/B/C/D GPIB cable to connect to an external computer or equipment.
5. Module slot
Ten slots are available for installing the modules. The B1500A can contain any combination of modules.
Allowable number of modules installed in one mainframe (each/mainframe):
HPSMU 4, MPSMU 10, HRSMU 10, CMU 1, SPGU 5, WGFMU 5
If the B1500A contains the WGFMU, sum of Rating for all module types in the mainframe must be < 60.
where Rating = Number of modules Rating for each module type
Rating for each module type: HPSMU 14, MPSMU 2, HRSMU 2, CMU 7,
SPGU 12, WGFMU 10
For example, if the B1500A installs two HPSMU, one CMU, and two WGFMU, the total rating is 2 14+7+2 10=55.
For each module, see “Measurement Units” on page 2-17. Also, there is a rule
for the installation order by the module type. See Chapter 3, “Installation.”
6. Circuit Common ( ) and Frame ground ( ) terminals
Normally, connect the terminals together by using the shorting bar (Agilent part number 5000-4206). For floating measurement, remove the shorting bar.
For floating measurement, do not apply voltage more than ±42 V to the Circuit
Common terminal. Failure to heed this caution may result in damage to the B1500A.
If the Circuit Common terminal is not connected to the frame ground terminal
(for floating measurement), a potential shock hazard may present. Do not touch any of measurement circuit at any time while a floating measurement is in progress.
7. Zero Check terminal
Ground reference point of the B1500A.
2- 12 Agilent B1500A User’s Guide, Edition 10
CAUTION
Introduction
Rear View
The Zero Check terminal can be used for the service purpose only. For the B1500A normal operation, leave this terminal open and do not connect anything to this terminal. Connecting anything can damage the B1500A.
8. GNDU terminal
0 V constant voltage source. Used for the reference of measurement ground.
Triaxial connector.
9. LAN interface
RJ45 connector.
10. USB interfaces
USB, 2 ports. For keyboard, mouse, or peripherals. USB keyboard and USB mouse are available as option.
To remove USB devices from the B1500A, use “Safely Remove Hardware” on
Windows taskbar. If it is not used, the B1500A may cause the internal USB communication error. If the error occurs, turn the B1500A off and disconnect the power cable from the B1500A. Leave it about 30 seconds before rebooting the
B1500A, and connect the power cable again, and then turn the B1500A on.
11. Ext Trig terminals
Two BNC connectors, one for trigger input, and one for trigger output. For details about the trigger function, see Programming Guide .
12. Digital I/O terminal
DSUB 25 pin connector. Can be used for the trigger input/output terminals or an interface to control an external relay circuit and so on. For details, see
Programming Guide . This connector is also used to connect Agilent 16445A selector adapter.
13. Interlock terminal
Used in conjunction with the interlock function of the B1500A. If the Interlock terminal is open, maximum SMU output is limited to ±42 V. Be sure to connect this terminal to the interlock circuit of the 16442B test fixture (B1500A-A5F) or the prober station before performing measurement. For the interlock circuit, see
“To Make an Interlock Circuit” on page 3-29.
To verify the interlock function, perform the interlock open/close test on the
Main Frame tab screen of the EasyEXPERT Configuration window.
Agilent B1500A User’s Guide, Edition 10 2- 13
WARNING
CAUTION
Introduction
Rear View
Dangerous voltage of up to the maximum voltage of SMUs may be present at force, guard, and sense terminals if the Interlock terminal is closed.
4
3
2
E
D
D
D
D
D
D
5
1
6
C
B
A
13 12 11 10 9 8 7
A. GNDU/ADC
Ground unit and A/D converter module. Always installed in the B1500A.
B. SPGU module
The semiconductor pulse generator unit (SPGU) has the Output 1 and Output 2 terminals and the following terminals to synchronize the operation between
SPGUs or with an external equipment.
Ref Out/Sync Out: Connect to the Ref In/Sync In of the slave SPGU.
Ref In/Sync In: Connect to the Ref Out/Sync Out of the master SPGU.
Trig Out: Connect to the trigger input terminal of the equipment synchronized with the SPGU output.
Connect the Ref Out/In, Sync Out/In, and Trig Out terminals to the specified terminal properly. Connecting to the other terminal may result in damage to the
SPGU.
2- 14 Agilent B1500A User’s Guide, Edition 10
CAUTION
NOTE
Introduction
Rear View
In the EasyEXPERT operation mode, the SPGU outputs can be specified by the
PG number. PG1 and PG2 are assigned to the Output 1 and Output 2 terminals of the SPGU at the lowest position. And the following PG numbers are assigned to the outputs of the upper SPGUs in sequence. Use the PG number label furnished with the B1500A or equivalent to identify the SPGU channel number.
C. WGFMU module
The waveform generator/fast measurement unit (WGFMU) has the Ch 1 and Ch
2 terminals and the following terminals to synchronize the operation between
WGFMUs or with an external equipment.
Sync Out: Connect to the Sync In of the slave WGFMU.
Sync In: Connect to the Sync Out of the master WGFMU.
Trig Out: Connect to the trigger input terminal of the equipment synchronized with the WGFMU output.
Connect the Sync Out/In, and Trig Out terminals to the specified terminal properly.
Connecting to the other terminal may result in damage to the WGFMU.
Connect the connection cable between the WGFMU and the RSU (remote-sense and switch unit) before turning the B1500A on. Changing the cable connection in the power on state may damage the WGFMU and RSU. See Agilent B1530A User’s
Guide for cable connection and usage.
D. SMU module
The source/monitor unit (SMU) has two triaxial connectors, force and sense, for the Kelvin connections. The HRSMU (high resolution SMU) also provides a
D-sub connector (To ASU terminal) which is used to connect the dedicated ASU
(atto sense and switch unit). The HPSMU (high power SMU) occupies two slots.
In the EasyEXPERT operation mode, the SMUs can be specified by the SMU number. SMU1 is assigned to the SMU at the lowest position. And the following
SMU numbers are assigned to the upper SMUs in sequence. Use the SMU number label furnished with the B1500A or equivalent to identify the SMU number.
To use the ASU, connect the connection cables between the HRSMU and the dedicated ASU before turning the B1500A on.
Agilent B1500A User’s Guide, Edition 10 2- 15
WARNING
CAUTION
Introduction
Rear View
There are potentially hazardous voltages (200 V for HPSMU, and 100 V for
MPSMU/HRSMU/ASU) present at the Force, Sense, and Guard terminals of
Agilent B1500A. To prevent electrical shock, the following safety precautions must be observed during the use of the B1500A.
a. Use a three-conductor AC power cable to connect the cabinet (if used) and the B1500A to an electrical ground (safety ground).
b. If you do not use the 16442B test fixture (B1500A-A5F), you must install and connect an interlock circuit that opens the Interlock terminal when the shielding box access door is opened.
c. Confirm periodically that the interlock function works normally.
d. Before touching the connections on the Force, Guard, and Sense terminals, turn the B1500A off and discharge any capacitors. If you do not turn the B1500A off, complete all of the following items, regardless of the B1500A settings.
• Press the Stop key to set the module output off.
• Confirm that the High Voltage indicator is not lit.
• Open the shielding box access door (open the Interlock terminal).
• Discharge any capacitors connected to an SMU.
e. Warn persons working around the B1500A about dangerous conditions.
E. CMU module
The multi frequency capacitance measurement unit (MFCMU) has four coaxial connectors, Lcur, Lpot, Hpot, and Hcur, for the four-terminal pair connection.
The Hcur and Hpot have to be connected together at a terminal of the device under test (DUT). Also the Lcur and Lpot have to be connected together at the other terminal of the DUT. Then, the guard lines of four-terminal pair must be connected together.
Do not apply voltage more than ±25 V to the MFCMU input terminals. Failure to heed this caution may result in damage to the module.
2- 16 Agilent B1500A User’s Guide, Edition 10
Figure 2-1
Introduction
Measurement Units
Measurement Units
Agilent B1500A can be equipped with the following measurement modules.
•
•
•
•
•
•
•
“WGFMU - Waveform Generator/Fast Measurement Unit”
See Agilent EasyEXPERT User’s Guide for the functions available for Agilent
EasyEXPERT software. See Programming Guide for the functions available for the
GPIB remote mode. See Agilent B1530A User’s Guide for using the WGFMU.
GNDU - Ground Unit
Agilent B1500A is equipped with the ground unit (GNDU). The GNDU is a 0 V constant voltage source, and used for the reference of measurement ground. Also the
GNDU can sink up to ± 4.2 A, so it is effective for using the HPSMU (high power
SMU). Figure 2-1 is a simplified circuit diagram of GNDU.
Simplified GNDU Circuit Diagram
9
*1'8
)RUFH
&RPPRQ
Agilent B1500A User’s Guide, Edition 10 2- 17
NOTE
Figure 2-2
Introduction
Measurement Units
About SMU
Source/monitor unit (SMU) can apply DC voltage or current, and can measure DC
current or voltage. Figure 2-2 is a simplified SMU circuit diagram. The SMU can
perform the following operations:
• Apply voltage and measures current
• Apply current and measures voltage
• Apply voltage and measures voltage
• Apply current and measures current
To select the SMU operation mode in the GPIB remote condition, enter the CMM command.
Simplified SMU Circuit Diagram
$
608
)RUFH
9
&RPPRQ
Compliance
The SMU has a compliance feature that limits output voltage or current to prevent damage to the device under test. When the SMU applies voltage, you can specify current compliance. When the SMU applies current, you can specify voltage compliance. For details about the compliance, see Agilent EasyEXPERT User’s
Guide .
2- 18 Agilent B1500A User’s Guide, Edition 10
Figure 2-3
Introduction
Measurement Units
HPSMU - High Power SMU
This section describes typical specification of the high power source/monitor unit
(HPSMU) for Agilent B1500A. Maximum four modules can be installed in one mainframe.
• Maximum voltage, current, output power: ± 200 V, ± 1 A, 20 W
• Minimum range: 2 V, 1 nA
•
Output/measurement value and resolution: see Table 2-1 to Table 2-4.
HPSMU Output and Measurement Ranges
&XUUHQWP$
9ROWDJH9
Agilent B1500A User’s Guide, Edition 10 2- 19
Table 2-1
Table 2-2
Introduction
Measurement Units
HPSMU Output Voltage Ranges and Resolutions
Range
2 V
20 V
40 V
100 V
200 V
Output Value
0
0
0
0
0
|V|
|V|
|V|
|V|
|V|
2 V
20 V
40 V
100 V
200 V
Setting
Resolution
100 V
1 mV
2 mV
5 mV
10 mV
1 nA
10 nA
100 nA
1 A
10 A
100 A
1 mA
10 mA
100 mA
HPSMU Output Current Ranges and Resolutions
Range
1 A
0
0
0
0
0
0
0
0
0
0
Output Value
|I|
|I|
|I|
|I|
|I|
|I|
|I|
|I|
|I|
|I|
1.15 nA
11.5 nA
115 nA
1.15
11.5
115
1.15 mA
11.5 mA
50 mA < |I|
50 mA < |I|
50 mA
125 mA < |I|
50 mA
115 mA
125 mA
500 mA < |I|
A
A
A
500 mA
1 A
Setting
Resolution
50 fA
500 fA
5 pA
50 pA
500 pA
5 nA
50 nA
500 nA
5 A
5 A
50 A
50 A
50 A
50 A
Maximum
Current
± 1000 mA
± 1000 mA
± 500 mA
± 125 mA
± 50 mA
Maximum
Voltage
± 200 V
± 100 V
± 200 V
± 100 V
± 40 V
± 20 V
± 200 V
± 200 V
± 200 V
± 200 V
± 200 V
± 200 V
± 200 V
± 200 V
2- 20 Agilent B1500A User’s Guide, Edition 10
Table 2-3
Table 2-4
Introduction
Measurement Units
2 V
20 V
40 V
100 V
200 V
HPSMU Measurement Voltage Values and Resolutions
Measurement Resolutions
Range
Measurement
Value a
0
0
0
0
0
|V|
|V|
|V|
|V|
|V|
2.2 V
22 V
44 V
110 V
200 V
High Speed ADC High Resolution ADC
100
1 mV
2 mV
5 mV
V
10 mV
2 V
20 V
40 V
100 V
200 V
HPSMU Measurement Current Values and Resolutions
Measurement Resolutions
Range Measurement Value a
High Speed ADC High Resolution ADC
1 nA
10 nA
100 nA
1 A
10 A
100 A
1 mA
10 mA
100 mA
1 A
0 |I| 1.15 nA
0 |I| 11.5 nA
0 |I| 115 nA
0 |I| 1.15 A
0 |I| 11.5 A
0 |I| 115 A
0 |I| 1.15 mA
0 |I| 11.5 mA
0
0
|I|
|I|
115 mA
1 A
50 fA
500 fA
5 pA
50 pA
500 pA
5 nA
50 nA
500 nA
5
50
A
A
10 fA
10 fA
100 fA
1 pA
10 pA
100 pA
1 nA
10 nA
100 nA
1 A a. This column is applied to the auto ranging or the limited auto ranging. For fixed ranging, maximum measurement value is Range column value.
Agilent B1500A User’s Guide, Edition 10 2- 21
Figure 2-4
Introduction
Measurement Units
MPSMU - Medium Power SMU
This section describes typical specification of the medium power source/monitor unit (MPSMU) for Agilent B1500A.
• Maximum voltage, current, output power: ± 100 V, ± 100 mA, 2 W
• Minimum range: 0.5 V, 1 nA
•
Output/measurement value and resolution: see Table 2-5 to Table 2-8.
MPSMU Output and Measurement Ranges
&XUUHQWP$
9ROWDJH9
2- 22 Agilent B1500A User’s Guide, Edition 10
Table 2-5
Table 2-6
MPSMU Output Voltage Ranges and Resolutions
Range
0.5 V
2 V
5 V
20 V
40 V
100 V
0
Output Value
0
|V|
|V|
0.5 V
2 V
0 |V| 5 V
0 |V| 20 V
0 |V| 20 V
20 V < |V| 40 V
0 |V| 20 V
20 V < |V| 40 V
40 V < |V| 100 V
Setting
Resolution
25 V
100 V
250 V
1 mV
2 mV
2 mV
5 mV
5 mV
5 mV
1 nA
10 nA
100 nA
1 A
10 A
100 A
1 mA
10 mA
100 mA
MPSMU Output Current Ranges and Resolutions
Range Output Value
0 |I| 1.15 nA
0 |I| 11.5 nA
0 |I| 115 nA
0 |I| 1.15 A
0 |I| 11.5 A
0 |I| 115 A
0 |I| 1.15 mA
0 |I| 11.5 mA
0 |I|
50 mA < |I|
20 mA
20 mA < |I|
50 mA
100 mA
Setting
Resolution
50 fA
500 fA
5 pA
50 pA
500 pA
5 nA
50 nA
500 nA
5 A
5 A
5 A
Introduction
Measurement Units
Maximum
Current
± 100 mA
± 100 mA
± 100 mA
± 100 mA
± 100 mA
± 50 mA
± 100 mA
± 50 mA
± 20 mA
Maximum
Voltage
± 100 V
± 100 V
± 100 V
± 100 V
± 100 V
± 100 V
± 100 V
± 100 V
± 100 V
± 40 V
± 20 V
Agilent B1500A User’s Guide, Edition 10 2- 23
Table 2-7
Table 2-8
Introduction
Measurement Units
MPSMU Measurement Voltage Values and Resolutions
Measurement Resolutions
Range
Measurement
Value a
0.5 V
2 V
5 V
20 V
40 V
100 V
0
0
0
0
0
0
|V|
|V|
|V|
|V|
|V|
|V|
0.55 V
2.2 V
5.5 V
22 V
44 V
100 V
High Speed ADC High Resolution ADC
25 V
100 V
250
1 mV
2 mV
5 mV
V
0.5 V
2 V
5 V
20 V
40 V
100 V
MPSMU Measurement Current Values and Resolutions
Range
Measurement
Value a
Measurement Resolutions
High Speed ADC High Resolution ADC
1 nA
10 nA
100 nA
1 A
10
100
A
1 mA
A
10 mA
0 |I| 1.15 nA
0 |I| 11.5 nA
0
0
|I|
|I|
115 nA
1.15 A
0 |I| 11.5 A
0 |I| 115 A
0 |I| 1.15 mA
0 |I| 11.5 mA
100 mA 0 |I| 100 mA
50 fA
500 fA
5 pA
50 pA
500 pA
5 nA
50 nA
500 nA
5 A
10 fA
10 fA
100 fA
1 pA
10 pA
100 pA
1 nA
10 nA
100 nA a. This column is applied to the auto ranging or the limited auto ranging.
For fixed ranging, maximum measurement value is Range column value.
2- 24 Agilent B1500A User’s Guide, Edition 10
Figure 2-5
Introduction
Measurement Units
HRSMU - High Resolution SMU
This section describes typical specification of the high resolution source/monitor unit (HRSMU) for Agilent B1500A.
• Maximum voltage, current, output power: ± 100 V, ± 100 mA, 2 W
• Minimum range: 0.5 V, 10 pA (1 pA when the E5288A ASU is used)
•
Output/measurement value and resolution: see Table 2-9 to Table 2-12.
HRSMU Output and Measurement Ranges
&XUUHQWP$
9ROWDJH9
Agilent B1500A User’s Guide, Edition 10 2- 25
Table 2-9
Table 2-10
Introduction
Measurement Units
HRSMU Output Voltage Ranges and Resolutions
Range
0.5 V
2 V
5 V
20 V
40 V
100 V
Output Value
0 |V| 0.5 V
0 |V| 2 V
0 |V| 5 V
0 |V| 20 V
0 |V| 20 V
20 V < |V| 40 V
0 |V| 20 V
20 V < |V| 40 V
40 V < |V| 100 V
Setting
Resolution
25 V
100 V
250 V
1 mV
2 mV
2 mV
5 mV
5 mV
5 mV
HRSMU Output Current Ranges and Resolutions
Range
1 pA a
10 pA
100 pA
1 nA
10 nA
100 nA
1 A
10 A
100 A
1 mA
10 mA
100 mA
Output Value
0 |I| 1.15 pA
0 |I| 11.5 pA
0 |I| 115 pA
0 |I| 1.15 nA
0 |I| 11.5 nA
0 |I| 115 nA
0 |I| 1.15 A
0 |I| 11.5 A
0 |I| 115 A
0 |I| 1.15 mA
0 |I| 11.5 mA
0 |I| 20 mA
20 mA < |I| 50 mA
50 mA < |I| 100 mA
Setting
Resolution
1 fA
5 fA
5 fA
50 fA
500 fA
5 pA
50 pA
500 pA
5 nA
50 nA
500 nA
5 A
5 A
5 A a. Available when the E5288A Atto Sense and Switch Unit (ASU) is used.
Maximum
Voltage
± 100 V
± 100 V
± 100 V
± 100 V
± 100 V
± 100 V
± 100 V
± 100 V
± 100 V
± 100 V
± 100 V
± 100 V
± 40 V
± 20 V
Maximum
Current
± 100 mA
± 100 mA
± 100 mA
± 100 mA
± 100 mA
± 50 mA
± 100 mA
± 50 mA
± 20 mA
2- 26 Agilent B1500A User’s Guide, Edition 10
Table 2-11
Table 2-12
Introduction
Measurement Units
HRSMU Measurement Voltage Values and Resolutions
Range
0.5 V
2 V
5 V
20 V
40 V
100 V
Measurement
Value a
0 |V| 0.55 V
0 |V| 2.2 V
0 |V| 5.5 V
0 |V| 22 V
0 |V| 44 V
0 |V| 100 V
Measurement Resolutions
High Speed ADC High Resolution ADC
25 V
100 V
250
1 mV
2 mV
5 mV
V
0.5 V
2 V
5 V
20 V
40 V
100 V
HRSMU Measurement Current Values and Resolutions
Range
Measurement
Value a
Measurement Resolutions
High Speed ADC High Resolution ADC
1 pA b
10 pA
100 pA
0
0
0
|I|
|I|
|I|
1.15 pA
11.5 pA
115 pA
1 nA
10 nA
100 nA
1 A
10
100
A
A
0 |I| 1.15 nA
0 |I| 11.5 nA
0
0
|I|
|I|
115 nA
1.15 A
0 |I| 11.5 A
0 |I| 115 A
1 mA
10 mA
0 |I| 1.15 mA
0 |I| 11.5 mA
100 mA 0 |I| 100 mA
100 aA
1 fA
5 fA
50 fA
500 fA
5 pA
50 pA
500 pA
5 nA
50 nA
500 nA
5 A
100 aA
1 fA / 400 aA b
2 fA / 500 aA b
10 fA
10 fA
100 fA
1 pA
10 pA
100 pA
1 nA
10 nA
100 nA a. This column is applied to the auto ranging or the limited auto ranging.
For fixed ranging, maximum measurement value is Range column value.
b. Available when the E5288A Atto Sense and Switch Unit (ASU) is used.
Agilent B1500A User’s Guide, Edition 10 2- 27
NOTE
NOTE
Introduction
Measurement Units
To connect ASU
The specifications are satisfied and guaranteed for the exclusive combination of the
ASU and the HRSMU. So confirm the serial number of the ASU and connect it to the dedicated HRSMU properly.
To connect the ASU, see “To Connect ASU” on page 3-17.
To confirm the serial number, see Agilent EasyEXPERT User’s Guide .
Before using 1 pA range
The measurement channel connected to the ASU supports the 1 pA range. To use the
1 pA range, set the 1 pA fixed range or the 1 pA limited auto ranging.
The B1500A automatically performs the compensation of the data measured by the
1 pA range and returns the compensated data. You can use either the pre-stored offset data or the pre-measured offset data.
To measure the offset data, perform the self-calibration before starting the measurement for a DUT. This offset data is temporarily memorized until the
B1500A is turned off.
2- 28 Agilent B1500A User’s Guide, Edition 10
Introduction
Measurement Units
MFCMU - Multi Frequency CMU
This section describes typical specification of the multi frequency capacitance measurement unit (CMU) for Agilent B1500A. The CMU performs the impedance measurement and returns the specified measurement data such as Cp-G. Only one module can be installed in one mainframe.
•
Measurement parameters: See Table 2-13.
• AC signal, output frequency:
1 kHz to 5 MHz
Setting resolution: 1 mHz (1 kHz to), 10 mHz (10 kHz to), 0.1 Hz (100 kHz to), or 1 Hz (1 MHz to 5 MHz)
• AC signal, output level:
10 mVrms to 250 mVrms, 1 mV resolution
• DC bias:
0 to ± 25 V, using MFCMU internal DC bias
0 to ± 100 V, using SMU and SCUU (SMU CMU unify unit)
• Measurement range:
For the fixed ranging mode, measurement range (impedance range) must be
calculation example of the impedance vs frequency characteristics of a capacitive load. Use these information to decide the measurement range.
Impedance Z is calculated by the following formula.
Z = 1 / (2 f C ) where f is frequency (Hz) and C is capacitance (F).
Agilent B1500A User’s Guide, Edition 10 2- 29
Table 2-13
Introduction
Measurement Units
Measurement Parameters
Primary Parameter
R (resistance, )
G (conductance, S)
Z (impedance, )
Z (impedance, )
Y (admittance, S)
Y (admittance, S)
Cp (parallel capacitance, F)
Cp (parallel capacitance, F)
Cp (parallel capacitance, F)
Cp (parallel capacitance, F)
Cs (series capacitance, F)
Cs (series capacitance, F)
Cs (series capacitance, F)
Lp (parallel inductance, H)
Lp (parallel inductance, H)
Lp (parallel inductance, H)
Lp (parallel inductance, H)
Ls (series inductance, H)
Ls (series inductance, H)
Ls (series inductance, H)
Secondary Parameter
X (reactance, )
B (susceptance, S)
(phase, radian)
(phase, degree)
(phase, radian)
(phase, degree)
G (conductance, S)
D (dissipation factor)
Q (quality factor)
Rp (parallel resistance, )
Rs (series resistance, )
D (dissipation factor)
Q (quality factor)
G (conductance, S)
D (dissipation factor)
Q (quality factor)
Rp (parallel resistance, )
Rs (series resistance, )
D (dissipation factor)
Q (quality factor)
2- 30 Agilent B1500A User’s Guide, Edition 10
Introduction
Measurement Units
Table 2-14
Impedance Z
0 Z < 100
100 Z < 300
300 Z < 1 k
1 k Z < 3 k
3 k Z < 10 k
10 k Z < 30 k
30 k Z < 100 k
100 k Z < 300 k
300 k Z
Measurement Range for Fixed Ranging Mode
Measurement range (impedance range)
1 kHz f 200 kHz 200 kHz < f 2 MHz 2 MHz < f 5 MHz
50
100
300
1 k
3 k
10 k
30 k
100 k
300 k
50
100
300
1 k
3 k
10 k
30 k
50
100
300
1 k
3 k
Figure 2-6 Impedance vs Frequency Characteristics of Capacitive Load, Calculation
Example
10 T 7
1 T 7
100 G 7
10 G 7
1 G 7
100 M 7
10 M 7
1 M 7
100 k 7
10 k 7
1 k 7
100 7
10 7
1 7
100 m 7
10 m 7
1 m 7
100 M7
10 M7
1 M7
100 n 7
10 n 7
1 kHz
50 7 range
10 kHz
300 k 7 range
100 kHz
Frequency f
1 MHz
3 k 7 range
100 aF
1 fF
10 fF
100 fF
1 pF
10 pF
100 pF
1 nF
10 nF
100 nF
1 M F
10 M F
100 M F
1 mF
10 mF
100 mF
1 F
5 MHz
Agilent B1500A User’s Guide, Edition 10 2- 31
Figure 2-7
Introduction
Measurement Units
HVSPGU - High Voltage SPGU
This section describes key specification of the high voltage semiconductor pulse generator unit (SPGU) for Agilent B1500A. Maximum five modules can be installed in one mainframe.
• Number of output channels: 2 channels per module
• Output impedance: 50
• Output level: 0 to ± 40 V (open load), ± 20 V (50 load), 1 mV resolution
• SPGU operation mode:
PG (pulse generator) or ALWG (arbitrary linear waveform generator)
• Channel output operation mode:
Free run, duration, or pulse count (PG mode)/sequence count (ALWG mode)
• PG output mode:
2-level pulse or 3-level pulse, for each channel
• Pulse timing parameters: (programmable range)
Period: 20 ns to 10 s, 10 ns resolution
Width: 10 ns to period 10 ns, resolution 2.5 ns or 10 ns (transition time > 8 s)
Delay: 0 to period 20 ns, resolution 2.5 ns or 10 ns (transition time > 8 s)
Transition time (leading time or trailing time): 8 ns to 400 ms, resolution 2 ns or
8 ns (transition time > 8 m s)
• Pulse switch, which is more durable than mechanical relays, and better suited for frequent switching applications.
• Automatic voltage level adjustment by specifying load impedance of DUT
SPGU Simplified Circuit Diagram
50
7
Pulse switch
50
7
Pulse switch
Output 1 Output 2
PG 2-level or 3-level or
ALWG
PG 2-level or 3-level or
ALWG
2- 32 Agilent B1500A User’s Guide, Edition 10
Figure 2-8
Introduction
Measurement Units
WGFMU - Waveform Generator/Fast Measurement
Unit
This section describes typical specification of the waveform generator/fast measurement unit (WGFMU) and the remote-sense and switch unit (RSU) for
Agilent B1500A. Maximum five modules can be installed in one mainframe.
• Number of channels: 2 channels per module
• Function:
Voltage output and current or voltage sampling measurement with minimum sampling interval of 5 ns
• Current measurement range: 1 A, 10 A, 100 A, 1 mA, or 10 mA
• Operation mode: PG mode, Fast IV mode, or DC mode
• PG mode:
ALWG (arbitrary linear waveform generator) voltage output and voltage measurement (VFVM).
Output level: 5 V to 5 V for open load or 2.5 V to 2.5 V for 50 load
Minimum pulse width: 100 ns
• Fast IV mode:
ALWG voltage output and current or voltage measurement (VFIM or VFVM).
Output level: 0 to 10 V, 0 to 10 V, or 5 V to 5 V
Minimum pulse width: 300 ns
• DC mode:
DC voltage output and current or voltage measurement (VFIM or VFVM).
Output level: 0 to 10 V, 0 to 10 V, or 5 V to 5 V
WGFMU Simplified Circuit Diagram
PG mode
50 7 V
ALWG
Ch1
RSU output
A
Fast IV mode
V
ALWG
PG mode
50 7 V
Fast IV mode
A
V
Ch2
RSU output
Agilent B1500A User’s Guide, Edition 10 2- 33
Introduction
Measurement Units
2- 34 Agilent B1500A User’s Guide, Edition 10
3 Installation
WARNING
Installation
This chapter describes how to install Agilent B1500A and accessories.
•
•
•
•
•
“Connecting Measurement Devices”
•
“Capacitance Compensation When Using Switching Matrix”
•
•
“To Enable System Controller” on page 3-10.
There are potentially hazardous voltages (200 V for HPSMU, and 100 V for
MPSMU/HRSMU/ASU) present at the Force, Sense, and Guard terminals of
Agilent B1500A. To prevent electrical shock, the following safety precautions must be observed during the use of the B1500A.
• Use a three-conductor AC power cable to connect the cabinet (if used) and the B1500A to an electrical ground (safety ground).
• If you do not use the 16442B test fixture (B1500A-A5F), you must install and connect an interlock circuit that opens the Interlock terminal when the shielding box access door is opened.
• Confirm periodically that the interlock function works normally.
• Before touching the connections on the Force, Guard, and Sense terminals, turn the B1500A off and discharge any capacitors. If you do not turn the B1500A off, complete all of the following items, regardless of the B1500A settings.
• Press the Stop key to set the module output off.
• Confirm that the High Voltage indicator is not lit.
• Open the shielding box access door (open the Interlock terminal).
• Discharge any capacitors connected to an SMU.
• Warn persons working around the B1500A about dangerous conditions.
3- 2 Agilent B1500A User’s Guide, Edition 10
Installation
Requirements
Requirements
This section contains information on:
•
•
•
“Storaging/Shipping Environment”
•
•
Power Requirements
The B1500A can operate from any single-phase AC power source supplying 90 to
264 V at 47 to 63 Hz. The maximum power consumption is 900 VA.
Operating Environment
The B1500A is specified to operate within the following environmental conditions:
Temperature: 5 C to 40 C
Humidity:
Altitude:
20 % to 70 % RH, non-condensing
0 to 2,000 m (6,561 ft.)
Storaging/Shipping Environment
The B1500A is specified to store/ship within the following environmental conditions:
Temperature: -20 C to 60 C
Humidity:
Altitude:
10 % to 90 % RH, non-condensing
0 to 4,600 m (15,092 ft.)
Agilent B1500A User’s Guide, Edition 10 3- 3
CAUTION
WARNING
Installation
Requirements
Installation Requirements
The B1500A has cooling fans. To ensure adequate airflow, make sure that there is sufficient clearance around the cooling fans: 6 inches (150 mm) behind, 3 inches (70 mm) on the sides, and 0.5 inch (12 mm) above and below.
If the airflow is restricted, the internal operating temperature will be higher. This may reduce the instrument's reliability, or cause the thermal-protection circuits to turn the instrument off.
Also make sure that there is enough space for connecting/disconnecting the power cable easily.
Power Cable
Before applying AC line power to the B1500A, ensure that the correct power cable is used.
In accordance with international safety standards, this instrument is equipped with a three-prong power cable. When connected to an appropriate AC power outlet, this cable grounds the instrument frame. The type of power cable shipped with each instrument depends on the country of destination. Refer to PN in the following table for Agilent part numbers of the power cables available.
If the plug on the cable does not fit the power outlet, or the cable is to be attached to a terminal block, cut the cable at the plug end and re-wire it. This work should be performed by a qualified electrician, observing all local electrical codes.
The color coding used in the cable will depend on the cable supplied. If a new plug is to be connected, it must meet local safety requirements and include the following features:
•
adequate load-carrying capacity (see Chapter 4, “Specifications,” on page 4-1.)
• ground connection
• cable clamp
For protection from electrical shock, do not interrupt the power cable ground.
3- 4 Agilent B1500A User’s Guide, Edition 10
Installation
Requirements
• Plug: BS 1363/A,
250 V, 10 A
• PN: 8120-4420
• Plug: AS 3112,
250 V, 10 A
• PN: 8120-4419
• Plug: CEE 7 sheet
VII, 250 V, 10 A
• PN: 8120-4519
• Plug: NEMA 5-15P,
125 V, 10 A
• PN: 8120-6825
• Plug: NEMA 6-15P,
250 V, 10 A
• PN: 8120-3996,
8120-0698
• Plug: SEV 1011,
250 V, 10 A
• PN: 8120-2104
• Plug: SR 107-2-D1,
250 V, 10 A
• PN: 8120-2956
• Plug: IS 1293 and
IS 6538, 250 V, 10 A
• PN: 8120-4211
• Plug: JIS C 8303,
125 V, 12 A
• PN: 8121-0743
• Plug: Israel SI 32,
250 V, 10 A
• PN: 8120-5182
• Plug: IRAM 2073-
10A, 250 V, 10 A
• PN: 8120-6870
• Plug: CEI 23-16,
250 V, 10 A
• PN: 8120-6978
• Plug: GB 1002 figure 3, 250 V, 10 A
• PN: 8120-8376
• Plug: SANS 164-1,
250 V, 10 A
• PN: 8120-4211,
8121-0564
• Plug: TISI 166, 250 V,
10 A
• PN: 8121-1866
• Plug: NBR 14136,
250 V, 10 A
• PN: 8121-1809
• Plug: CNS 10917-2,
125 V, 10 A
• PN: 8120-6825,
8121-1635
• Plug: CS 0017:2003,
250 V, 10 A
• PN: 8120-8871,
8121-1638
Agilent B1500A User’s Guide, Edition 10 3- 5
Installation
Inspection and Installation
Inspection and Installation
This section describes what to do when you receive the B1500A and accessories.
1. Inspect the shipment. See “To Inspect B1500 and Accessories”.
2. Verify the B1500A operation and perform initial setup. See “To Perform Initial
3. Install the B1500A in the appropriate place. See “Requirements” on page 3-3.
To use the B1500A briefly, see “Getting Started” on page 1-1.
To change the Windows logon setting, see “To Change Windows Logon Setting” on page 3-9.
To change the GPIB address of the B1500A, see “To Change GPIB Address” on page 3-9.
To allow the B1500A/EasyEXPERT to control external GPIB devices, see “To
Enable System Controller” on page 3-10.
To Inspect B1500 and Accessories
Perform the following inspections when the B1500A and accessories arrive at your site.
1. Before unpacking any components, inspect all boxes for any signs of damage that might have occurred during shipment, such as:
• dents
• scratches
• cuts
• water marks
If you suspect any damage, notify your local Agilent Technologies sales or service office.
2. When you open the boxes that contain the B1500A and accessories, check the components against the contents lists attached to the boxes.
If anything is missing, notify your local Agilent Technologies sales or service office.
3- 6 Agilent B1500A User’s Guide, Edition 10
Installation
Inspection and Installation
To Perform Initial Setup
After you receive the B1500A, perform the following setup.
1. Make sure that the Standby switch is set to off.
2. On the B1500A rear panel, connect the Circuit Common terminal to the frame ground terminal by using a shorting-bar.
3. If you use Agilent 16444A-001 USB keyboard and/or the 16444A-002 USB mouse, connect it to an USB port of the B1500A.
4. Connect the power cable from the B1500A to an AC power outlet.
5. Open the measurement terminals and press the Standby switch to turn on the
B1500A.
If the B1500A is operating correctly, the power-on self-test is automatically performed. If problems arise, see Agilent EasyEXPERT User’s Guide .
6. Wait for the Welcome to Microsoft Windows screen. On the screen, select the
Next button.
7. For the message How should dates and currency appear?
, set as follows:
• I live closest to this region: (for example, United States)
• I type mostly in this language: (for example, English)
• I use this type of keyboard: (for example, US)
If you use the 16444A-001 USB keyboard, select US.
8. Select the Next button.
9. For the message What time zone are you in?
, select your present location (for example, Pacific Time (US & Canada); Tijuana). Then select the Next button.
10. For The End User License Agreement , select Yes, I accept . Then select the Next button.
11. For the message Help protect your PC , select Not right now . Then select the
Next button.
12. For the message What’s your computer’s name?
, do not anything. Just select the
Next button.
13. For the message What’s your Administrator password?
, do not anything. Just select the Next button.
14. For the message Checking your internet connectivity , select the Skip button.
Agilent B1500A User’s Guide, Edition 10 3- 7
NOTE
NOTE
Installation
Inspection and Installation
15. For the message Thank you!
, select the Finish button. Agilent Recovery Image
Setup dialog box is displayed.
16. For the dialog box, click OK.
The initial setup will be completed. And the B1500A internal Windows will have the following setup.
• Location: United States
• Language: English
• Keyboard: English (US)
• Time Zone: Pacific Time (US & Canada); Tijuana
• Network connection: none
• Computer name: Unique name set by factory
You can change the computer name after the initial setup. It must be unique.
• Password of Administrator: not defined
You can set the password after the initial setup. If you set it, do not forget it.
• Pre-defined users: Administrator, Agilent B1500 User, and AgilentOnly
You can add users after the initial setup. Add users as you need.
Agilent B1500 User is the account for automatic logon. Password is not set to this account.
AgilentOnly is the account for Agilent service personnel. Do not delete this account. This account is password protected.
Other Windows setup
You can set other setup of Windows after the initial setup. It is your responsibility.
If you connect Agilent B1500 to the network, take care to protect it from computer virus.
Agilent Technologies cannot guarantee the performance and provide compatibility information for all B1500s under several conditions. If problems arise, perform
Agilent B1500 system recovery. To perform recovery, see Agilent EasyEXPERT
User’s Guide .
3- 8 Agilent B1500A User’s Guide, Edition 10
NOTE
Installation
Inspection and Installation
To Change Windows Logon Setting
Agilent B1500A initially enables Windows automatic logon. If you want to change this setting, select All Programs > Control Auto Logon from the Start menu. Control
Auto Logon is displayed on the browser. Then click one of the following buttons on the browser and follow the setup script.
• Enable Auto Logon
• Disable Auto Logon
If you set a password for the user account Agilent B1500 User , disable the automatic logon.
To Change GPIB Address
When Agilent B1500A is shipped from the factory, the GPIB address is set to 17. To change the GPIB address, perform the following procedure.
1. If the EasyEXPERT software is running, terminate it as shown below: a. Select the menu function File > Exit on the EasyEXPERT main screen.
b. Click [x] at the upper right corner of the Start EasyEXPERT button.
2. Select All Programs > Agilent IO Libraries Suite > Agilent Connection Expert from the Start menu. Agilent Connection Expert window appears.
3. At the Instrument I/O on this PC area, select GPIB0, and click the Change
Properties... button. Agilent 82350 PCI GPIB Interface - GPIB0 window appears.
4. Change the GPIB Address value.
5. Remove the check from the Auto-discover instruments connected to this interface box.
6. Click the OK button on Agilent 82350 PCI GPIB Interface - GPIB0 window.
7. On the Reboot Required dialog box, click the Reboot Now button, and reboot the B1500A.
Agilent B1500A User’s Guide, Edition 10 3- 9
NOTE
Installation
Inspection and Installation
To Enable System Controller
To allow Agilent B1500A/EasyEXPERT to control external GPIB devices, perform the following procedure.
1. If the EasyEXPERT software is running, terminate it as shown below: a. Select the menu function File > Exit on the EasyEXPERT main screen.
b. Click [x] at the upper right corner of the Start EasyEXPERT button.
2. Select All Programs > Agilent IO Libraries Suite > Agilent Connection Expert from the Start menu. Agilent Connection Expert window appears.
3. At the Instrument I/O on this PC area, select GPIB0, and click the Change
Properties... button. Agilent 82350 PCI GPIB Interface - GPIB0 window appears.
4. Set the GPIB Address value to 21 that is the typical address number for the system controller.
5. Check the System Controller box.
6. Remove the check from the Auto-discover instruments connected to this interface box.
This disables the automatic device detection. So the Connection Expert cannot detect the instruments connected to the GPIB interface by itself.
7. Click the OK button on Agilent 82350 PCI GPIB Interface - GPIB0 window.
8. On the Reboot Required dialog box, click the Reboot Now button, and reboot the B1500A.
To Disable System Controller
If the B1500A is the system controller, you cannot control the B1500A by using an external computer. To disable the system controller, change the steps 4 and 5 for setting the GPIB Address value to not 21 and removing the check from the System
Controller box, and perform the procedure to the step 8.
3- 10 Agilent B1500A User’s Guide, Edition 10
NOTE
WARNING
WARNING
CAUTION
CAUTION
Installation
Installing Accessories
Installing Accessories
This section describes how to install the B1500A and accessories. Additional
information regarding airflow can be found in the “Installation Requirements” on page 3-4.
This section describes how to:
•
“To Connect 16442B Test Fixture (B1500A-A5F)”
•
•
•
•
•
Before connecting accessory to MFCMU
Turn the B1500A off before connecting the SCUU, the SCUU cable, or the CMU cable to the MFCMU.
There are potentially hazardous voltages of up to ± 100 V (MPSMU/HRSMU) or ± 200 V (HPSMU) at the Force, Sense, and Guard terminals. To prevent electrical shock, do not expose these lines.
To prevent electrical shock during use, install an interlock circuit (see
page 3-29) and connect the Interlock cable (see page 3-16).
The GNDU can sink current of up to 4.2 A. Use Agilent 16493L GNDU cable to connect the GNDU to a test fixture or a connector plate.
Do not use normal triaxial cable (Agilent 16494A) because the maximum current rating of the cable is 1 A.
Never connect the Guard terminal to any output, including circuit common, chassis ground, or any other guard terminal. Doing so will damage the SMU.
Agilent B1500A User’s Guide, Edition 10 3- 11
Installation
Installing Accessories
To Connect 16442B Test Fixture (B1500A-A5F)
See this section if you use Agilent 16442B test fixture (B1500A-A5F). This section describes how to set up the 16442B and how to connect the B1500A to the 16442B.
To Set up 16442B (B1500A-A5F)
You can stabilize the 16442B (B1500A-A5F) as shown in the figure below.
NOTE
1. Put a stabilizer on both sides of the test fixture.
2. Attach each stabilizer to the unit with a flathead screw.
To Connect 16442B (B1500A-A5F)
Use the cables shown in Table 3-1 to connect from the B1500A connectors to the
16442B’s relative connectors.
Making non-Kelvin connection
The Force terminals can be used to force and measure DC voltage or current. If you want to simplify the cable connections, open the Sense terminals and connect the
Force terminals only to the test fixture by using the triaxial cables.
If you make the Kelvin connection, use both Force and Sense terminals. Connecting the Force and Sense lines together at the terminal of the device under test minimizes the measurement error caused by the residual resistance of the connection cables.
The Kelvin connection is effective for the low resistance measurement and the high current measurement.
3- 12 Agilent B1500A User’s Guide, Edition 10
Table 3-1
Installation
Installing Accessories
To Connect 16442B (B1500A-A5F)
Cables
16442B
Terminals
B1500A Terminals
Agilent 16493J Interlock Cable, 3 m or 1.5 m
Agilent 16493L GNDU Cable, 3 m or 1.5 m
Agilent 16493K Kelvin Triaxial Cable, 3 m or 1.5 m, for the Kelvin connection
Up to 3 SMUs can be connected to the
16442B by the Kelvin connection.
Agilent 16494A Triaxial Cable, 3 m or 1.5 m, for the non-Kelvin connection
Agilent 16493P SPGU Cable, 3 m or 1.5 m
Agilent N1300A CMU Cable a
, 3 m or 1.5 m
SMU1
SMU2
SMU3
SMU4
SMU5
SMU6
PGU1
PGU2
PGU1
PGU2
Intlk
GNDU
SMU1
SMU2
SMU3
SMU4
SMU5
SMU6 a. To extend the four-terminal pair (4TP) connection to the 16442B inputs, connect the Hcur and Hpot cables together and the Lcur and Lpot cables together by using the BNC T-type adapter (female-female-male, Agilent part number 1250-2405), then connect them to the 16442B inputs.
To extend the 4TP connection to the socket module inputs, connect the cables to the PGU1, PGU2, VSU1, VSU2, VMU1, or VMU2 connector individually, and connect the Hcur and Hpot terminals together and the
Lcur and Lpot terminals together at the socket module inputs.
It is ok to leave open the ground wire extended from the CMU cable.
SMU
Interlock
GNDU
Force
Sense
SMU
SMU
Force
Sense
Force
Sense
SMU
SMU
SMU
SMU
Force
Force
Force
Force
SMU
SMU
Force
Force
SPGU Output 1
Output 2
CMU Hcur/Hpot
Lcur/Lpot
Agilent B1500A User’s Guide, Edition 10 3- 13
NOTE
Table 3-2
Installation
Installing Accessories
To Connect Connector Plate
The available connector plates are listed in Table 3-2. Option 001 provides the
through connectors except for the Interlock connector that provides the soldering patterns at the back side. For the option 002, the back of each connector is designed for soldering. For connector plate installation information, refer to Agilent 16495
Installation Guide .
For the 16495H/J, the insulator is inserted between the panel and the outer conductor of Triax connectors/BNC connectors.
Use the cables shown in Table 3-3 to connect from the B1500A connectors to the
connector plate’s relative connectors. For the cable connections from the connector
plate to the DUT interface such as manipulator and probe card, see “Mounting
Connectors” on page 3-27 as reference.
Making non-Kelvin connection
The Force terminals can be used to force and measure DC voltage or current. If you want to simplify the cable connections, open the Sense terminals and connect the
Force terminals only to the connector plate by using the triaxial cables.
If you make the Kelvin connection, use both Force and Sense terminals. Connecting the Force and Sense lines together at the terminal of the device under test minimizes the measurement error caused by the residual resistance of the connection cables.
The Kelvin connection is effective for the low resistance measurement and the high current measurement.
Connector Plates
Model Option Item Connectors
16495F 16495F-001 Triax. (f-f) 12, GNDU (f-f) 1, Interlock (f) 1
16495F-002 Triax. (f) 12, GNDU (f) 1, Interlock (f) 1
16495G 16495G-001 Triax. (f-f) 24, GNDU (f-f) 1, Interlock (f) 1
16495G-002 Triax. (f) 24, GNDU (f) 1, Interlock (f) 1
16495H 16495H-001 Triax. (f-f) 6, Coax. (f-f) 6, GNDU (f-f) 1, Interlock (f) 1
16495H-002 Triax. (f) 6, Coax. (f) 6, GNDU (f) 1, Interlock (f) 1
16495J 16495J-001 Triax. (f-f) 8, Coax. (f-f) 4, GNDU (f-f) 1, Interlock (f) 1
16495J-002 Triax. (f) 8, Coax. (f) 4, GNDU (f) 1, Interlock (f) 1
16495K 16495K-001 Connector plate, rubber holder
3- 14 Agilent B1500A User’s Guide, Edition 10
Table 3-3
Installation
Installing Accessories
To Connect Connector Plate
Cables
Connector
Plate
B1500A Terminals
Agilent 16493J Interlock Cable, 3 m or 1.5 m
Agilent 16493L GNDU Cable, 3 m or 1.5 m
Agilent 16493K a
Kelvin Triaxial Cable, 3 m or
1.5 m, for the Kelvin connection
16495F provides the inputs 1 to 12 (6 Kelvin).
16495H provides the inputs 1 to 6 (3 Kelvin).
16495J provides the inputs 1 to 8 (4 Kelvin).
Agilent 16494A Triaxial Cable, 3 m or 1.5 m, for non-Kelvin connection
16495H provides the inputs 1 to 6.
16495J provides the inputs 1 to 8.
Agilent 16493P SPGU Cable, 3 m or 1.5 m
16495H provides the inputs 7 to 12.
16495J provides the inputs 9 to 12.
Agilent N1300A CMU Cable b , 3 m or 1.5 m
16495H provides the inputs 7 to 12.
16495J provides the inputs 9 to 12.
Intlk
GNDU odd number even number odd number or even number odd number or even number odd number or even number
SMU
SMU
SPGU
CMU
Interlock
GNDU
Force
Sense
Force
Output 1
Output 2
Hcur/Hpot
Lcur/Lpot a. Use Agilent 16494B Kelvin Triaxial Cable to connect to Agilent E5250A
Low Leakage Switch Mainframe or the connector plate for Agilent 4142B
Modular DC Source/Monitor by the Kelvin connection.
b. To extend the four-terminal pair (4TP) connection to the connector plate inputs, connect the Hcur and Hpot cables together and the Lcur and Lpot cables together by using the BNC T-type adapter (female-female-male, Agilent part number 1250-2405), then connect them to the connector plate inputs.
To extend the 4TP connection to the DUT interface, connect the cables to the connector plates input connectors individually, and connect the Hcur and
Hpot terminals together and the Lcur and Lpot terminals together on the DUT
It is ok to leave open the ground wire extended from the CMU cable.
Agilent B1500A User’s Guide, Edition 10 3- 15
Installation
Installing Accessories
Connecting the interlock terminal
The B1500A provides the Interlock connector to prevent you from receiving an electrical shock from high voltage (more than ± 42 V). If the Interlock connector is open, the B1500A cannot force high voltage more than ± 42 V.
When using the 16442B test fixture (B1500A-A5F), connect the Interlock connectors together using the 16493J interlock cable.
If you use the 16495F/G/H/J connector plate, your own connector plate, or your own
connector by using the 16493J interlock cable.
3- 16 Agilent B1500A User’s Guide, Edition 10
NOTE
Figure 3-1
Installation
Installing Accessories
To Connect ASU
Agilent E5288A Atto Sense and Switch Unit (ASU) will add the 1 pA range to the high resolution SMU (HRSMU) when it is connected between the HRSMU and the device under test (DUT). The ASU also provides the input selection function when instruments are connected to the SMU input and the AUX input.
For the installation of the ASU and the connection to the DUT interface (probe card, manipulators, and so on), contact your favorite prober vender. The prober vender will have the solutions. Dimensions of the ASU are 132 mm (W) 88.5 mm (H)
50 mm (D) excluding the connectors.
Image of ASU Installation
.
6KLHOGLQJER[
&085HWXUQ
'87LQWHUIDFH
&085HWXUQ
.
$68 $68
3UREHU
7R%$&08
Required parts • Agilent 16495K Connector plate
• Agilent 16493M ASU cable
• Agilent N1300A CMU cable or Agilent 16048D/E test leads
• Agilent N1254A-108 Magnet stand
• BNC cable, coaxial cable, manipulator, wire, and so on
To install 16495K Fix the 16495K plate to the shielding box or something that will cover the DUT interface. See Agilent 16495 Installation Guide . The 16495K is the plate that has the mechanism to block the light from the cable hole used to pass the cables in the shielding box.
Agilent B1500A User’s Guide, Edition 10 3- 17
Installation
Installing Accessories
To install ASU
To connect
B1500A
NOTE
1. Fix the ASU in the shielding box. The ASU must be fixed to the best position for accessing its connectors. Agilent N1254A-108 Magnetic Stand will be useful for fixing the ASU.
2. Pass the 16493M (D-sub cable, triaxial cable), N1300A CMU cable, 16048D/E test leads, BNC cable and so on through the cable hole of the 16495K. They will be connected between the ASU and the instruments
3. Connect the D-sub cable to the ASU D-sub connector.
Connect the triaxial cable to the ASU Force terminal.
Connect the cable to the ASU CMU-cur/AUX In terminal. See Figure 3-2.
• For the MFCMU, connect the N1300A CMU cable.
• For Agilent 4284A LCR meter, connect Agilent 16048D/E test leads.
• For the instrument other than the MFCMU or the 4284A, connect the BNC cable to the CMU-cur/AUX In terminal. And open the CMU-pot terminal or cover it by using the BNC open cap.
4. Adjust the cable length in the shielding box, and catch in the cables by using the cover of the 16495K.
5. Connect the cable extended from the DUT interface to the ASU output terminal.
For the non Kelvin connection, open the Sense terminal or cover it by using the triaxial open cap.
1. Turn the B1500A off.
2. Connect the D-sub cable from the ASU to the HRSMU D-sub connector.
3. Connect the triaxial cable from the ASU to the HRSMU Force terminal.
The specifications of the ASU are guaranteed while it is connected to the exclusive
HRSMU. Confirm the serial number of the ASU, and connect it properly. See
Agilent EasyEXPERT User’s Guide .
To connect other instrument to AUX
To connect the instrument other than the MFCMU or the 4284A:
1. Turn the instrument off.
2. Connect the BNC cable from the ASU CMU-cur/AUX In terminal to the instrument. Prepare an adapter if the instrument’s input/output connector is not
BNC.
3- 18 Agilent B1500A User’s Guide, Edition 10
Figure 3-2
Figure 3-3
Installation
Installing Accessories
To Connect ASU
7R&08
+F
+S
7R608
)RUFH
'VXE
7R&08
/F
/S
7R608
)RUFH
'VXE
$68
&08FXU$8;,Q
&08SRW
)RUFH
)URP608
)RUFH&08$8;
6HQVH
&085HWXUQ$8;&RPPRQ
$68
&08FXU$8;,Q
&08SRW
)RUFH
)URP608
&085HWXUQ$8;&RPPRQ
)RUFH&08$8;
6HQVH
7R'87
7R'87
To Set Shorting Bar
5 / 8
6 / 9
AUX
CMU-cur/AUX In b / c
SMU Force
SMU Force
Shorting bar
Agilent B1500A User’s Guide, Edition 10 3- 19
Installation
Installing Accessories
To connect
MFCMU/4284A to
AUX
Perform the following procedure to connect the MFCMU or the 4284A. See Figure
Prepare a shorting bar furnished with the ASU. The shorting bar is effective for reducing the offset capacitance caused by connecting a measurement terminal to the chuck of a wafer prober.
1. Turn the instrument off.
2. Prepare two ASUs (#1 and #2) and two shorting bar. And perform the following procedure for each ASU.
a. Disconnect the triaxial cable from the ASU if it is connected to the ASU
Force terminal.
b. Face the concave side of the shorting bar to front.
c. Slide the shorting bar from the right side of the connectors.
3. Connect the cable to the instrument. For the MFCMU, use the N1300A CMU cable. For the 4284A, use the 16048D/E test leads. It is ok to leave open the ground wire extended from the cable.
4. Connect the high potential (Hp) cable of the test leads to the ASU #1 CMU-pot terminal.
5. Connect the high current (Hc) cable to the ASU #1 CMU-cur/AUX In terminal.
The shorting bar is fixed to the ASU #1 by the step 5 and 6.
6. Connect the triaxial cable from the HRSMU #1 Force terminal to the ASU #1
Force terminal.
7. Connect the low potential (Lp) cable to the ASU #2 CMU-pot terminal.
8. Connect the low current (Lc) cable to the ASU #2 CMU-cur/AUX In terminal.
The shorting bar is fixed to the ASU #2 by the step 8 and 9.
9. Connect the triaxial cable from the HRSMU #2 Force terminal to the ASU #2
Force terminal.
10. Prepare the connection wire (both pin terminals) furnished with the ASU and connect it between the CMU Return terminals of the ASU #1 and ASU #2 together.
NOTE
About ASU output cables
To perform capacitance measurements accurately, the cable length between DUT and the ASU output must be as short as possible.
3- 20 Agilent B1500A User’s Guide, Edition 10
NOTE
Figure 3-4
Installation
Installing Accessories
To Connect SCUU/GSWU
Agilent N1301A-100 SMU CMU Unify Unit (SCUU) is used to switch the module
(CMU or SMU) to be connected to the DUT. The SCUU is available for the
MPSMU and HRSMU.
Agilent N1301A-200 Guard Switch Unit (GSWU) is used to connect the CMU high and low guard lines together near the DUT. The connection is broken when the
SCUU is in the SMU connection state. The GSWU is effective for the accurate impedance measurement.
For the installation of the SCUU/GSWU and the connection to the DUT interface
(probe card, manipulators, and so on), contact your favorite prober vender. The prober vender will have the solutions. Dimensions of the SCUU are 148 mm (W)
75 mm (H) 70 mm (D). Dimensions of the GSWU are 33.2 mm (W) 41.5 mm
(H) 32.8 mm (D).
Image of GSWU Installation
.
6KLHOGLQJER[
*6:8
:LUHIURP&08*XDUG
'87LQWHUIDFH
7R%$
6&88
3UREHU
Required parts • Agilent 16495K Connector plate
• Agilent N1301A-201/202 GSWU cable (if GSWU is used)
• Agilent N1301A-102 SCUU cable (if SCUU is not attached to the MFCMU)
• Agilent N1301A-110 Magnet stand (if GSWU is used)
• BNC cable, coaxial cable, manipulator, wire, and so on
Agilent B1500A User’s Guide, Edition 10 3- 21
Installation
Installing Accessories
To install 16495K Fix your necessary 16495 connector plates to the shielding box or something that will cover the DUT interface. See Agilent 16495 Installation Guide . For the GSWU installation, the 16495K is required. It is the plate that has the mechanism to block the light from the cable hole used to pass the cables in the shielding box.
Before starting 1. GSWU is furnished with wires (2 ea.) for the connection between the GSWU and the DUT interface Guard terminal. If it is too short to connect them, prepare additional wire.
2. Turn the B1500A off.
Figure 3-5 To Connect SCUU/GSWU
7R&08
VORW1
+F
+S
/F
/S
7R608
VORW1
)RUFH
6HQVH
7R608
VORW1
)RUFH
6HQVH
6&88
)RUFH&08+
6HQVH
6HQVH
)RUFH&08/
'87
*XDUG
*6:8
*XDUG
3- 22 Agilent B1500A User’s Guide, Edition 10
To connect
SCUU/GSWU 1
NOTE
Installation
Installing Accessories
To attach the SCUU to the B1500A:
1. Attach the SCUU to the B1500A rear panel connectors for the MFCMU in the slot N and two SMUs in the slots N-1 and N-2 (N: integer, 3 to 10).
Connection will be easy by bringing the control connectors together before bringing the BNC connectors.
2. Fix the GSWU in the shielding box. The GSWU must be fixed to the best position for accessing its connectors.
3. Pass the GSWU cable (Agilent N1301A-201/202) through the cable hole of the
16495K. And connect it between the SCUU and the GSWU.
4. Adjust the cable length in the shielding box, and catch in the cables by using the cover of the 16495K.
5. Connect the proper cables from Force1/CMUH and Force2/CMUL to the 16495
connector plates or the DUT interface. See Figure 3-5.
For the Kelvin connections, also connect the proper cables from Sense1 and
Sense2 to the 16495 connector plates or the DUT interface.
6. Connect the wires (furnished, 2 ea.) to the GSWU.
7. Connect one of the wires to the Guard terminal extended from CMUH of SCUU.
Then the wire should contact the Guard terminal as close to the device as possible.
8. Connect another one to the Guard terminal extended from CMUL of SCUU.
Then the wire should contact the Guard terminal as close to the device as possible.
About SCUU output cables
To perform capacitance measurements accurately, the cable length between DUT and the SCUU output must be as short as possible.
To connect
SCUU/GSWU 2
1. Attach an end of the SCUU cable (Agilent N1301A-102) to the SCUU.
Connection will be easy by putting the SCUU and the cable connection box on the flat table, and bringing the control connectors together before bringing the
BNC connectors.
If the SCUU is fixed inside the shielding box, pass the SCUU cable through the cable hole of the 16495K.
Agilent B1500A User’s Guide, Edition 10 3- 23
NOTE
Installation
Installing Accessories
2. Fix the SCUU inside or outside the shielding box. The SCUU must be fixed to the best position for accessing its connectors. Agilent N1301A-110 Magnetic
Stand will be useful for fixing the SCUU.
3. Attach the other end of the SCUU cable to the B1500A rear panel connectors for the MFCMU in the slot N and two SMUs in the slots N-1 and N-2 (N: integer, 3 to 10).
Connection will be easy by bringing the control connectors together before bringing the BNC connectors.
4. Fix the GSWU in the shielding box. The GSWU must be fixed to the best position for accessing its connectors.
5. Connect the GSWU cable (Agilent N1301A-201/202) between the SCUU and the GSWU.
If the SCUU is fixed outside the shielding box, pass the GSWU cable through the cable hole of the 16495K.
6. Adjust the cable length in the shielding box, and catch in the cables by using the cover of the 16495K.
7. Connect the proper cables from Force1/CMUH and Force2/CMUL to the 16495
connector plates or the DUT interface. See Figure 3-5.
For the Kelvin connections, also connect the proper cables from Sense1 and
Sense2 to the 16495 connector plates or the DUT interface.
8. Connect the wires (furnished, 2 ea.) to the GSWU.
9. Connect one of the wires to the Guard terminal extended from CMUH of SCUU.
Then the wire should contact the Guard terminal as close to the device as possible.
10. Connect another one to the Guard terminal extended from CMUL of SCUU.
Then the wire should contact the Guard terminal as close to the device as possible.
About SCUU output cables
To perform capacitance measurements accurately, the cable length between DUT and the SCUU output must be as short as possible.
3- 24 Agilent B1500A User’s Guide, Edition 10
Figure 3-6
Table 3-4
Installation
Installing Accessories
To Connect GNDU Adapter
The ground unit (GNDU) output is the single triaxial connector. Agilent
N1254A-100 GNDU to Kelvin Adapter enables to change it to the dual triaxial connector. Connect the adapter to the GNDU connector on the rear panel, then connect a Kelvin triaxial cable to extend the GNDU terminal. Maximum current is
restricted when the Kelvin triaxial cable is used. See Table 3-4.
Agilent N1254A-100 GNDU to Kelvin Adapter
$JLOHQW1$*1'8WR.HOYLQ$GDSWHU
)RUFH
7ULD[LDOPDOH
&RPPRQ
7R*1'8FRQQHFWRU
6HQVH
'XDO7ULD[LDOIHPDOH
7R..HOYLQWULD[LDOFDEOH
Kelvin Triaxial Cable and Maximum Current
Model No. or
Option Item
16493K-001
16493K-002
Description
1.5 m Kelvin Triaxial Cable
3 m Kelvin Triaxial Cable
Maximum
Current
3.0 A
2.6 A
Agilent B1500A User’s Guide, Edition 10 3- 25
Figure 3-7
Installation
Installing Accessories
To Interconnect SPGUs
If multiple SPGUs have been installed, connect the SPGUs by using the following
• SPGU-SPGU connection cable16493Q, (number of SPGUs 1) 2 ea.
• SMA open cap, 4 ea.
SPGU Module Connection Example, Four Modules
SMA open cap 16493Q SMA-SMA cable
Slave SPGU
CAUTION
Master SPGU
Trig Out
Ref Out
Ref In
Sync Out
Sync In
Output 1
Output 2
If multiple SPGUs have been installed, connect the SPGUs as shown in Figure 3-7.
This connection makes it possible to perform the synchronous output by the multiple SPGU channels. In this figure, the master SPGU is the module which outputs the reference signal and the slave SPGUs are the modules which follow to the reference signal.
The Trig Out terminal must be connected to the trigger input terminal of the external equipment to make the synchronized operation of it.
Connect the Ref Out/In, Sync Out/In, and Trig Out terminals to the specified terminal properly. Connecting to the other terminal may result in damage to the
SPGU.
3- 26 Agilent B1500A User’s Guide, Edition 10
Installation
Mounting Connectors
Mounting Connectors
Previous sections described how to install the available accessories, and Agilent
16495 Installation Guide provides the information on how to install connector plates on the shielding box. However, you may choose to mount connectors directly on your own connector plate or test fixture.
To do this, you will need to make connector holes and mount the connectors yourself. This section contains information on connector hole dimensions.
To mount connectors:
1. Select the appropriate parts for your application. See Table 3-5.
2. Make the holes and mount the connectors. See Table 3-6.
For Kelvin connections, use Agilent 16493K Kelvin triaxial cable. The Kelvin triaxial cable requires a Kelvin triaxial connector, which has two connector holes and three screw holes.
3. Build the interlock circuit shown in “To Make an Interlock Circuit” on page
4. Attach cables from the connectors to the DUT (device under test). See “To
Connect GNDU Output” on page 3-32, “To Connect SMU Output” on page
3-33, and “To Connect MFCMU Output” on page 3-39.
Agilent B1500A User’s Guide, Edition 10 3- 27
Table 3-5
Table 3-6
Installation
Mounting Connectors
Recommended Parts
Usage
Making an interlock circuit
Connecting GNDU to DUT
Connecting SMU to
DUT
Connecting MFCMU to DUT
Agilent Part No. Description
1252-1419 Interlock Connector (6 pin, female)
3101-0302 or 3101-3241 Switch
1450-0641
8150-5680
LED (V
F
2.1 V @ I
F
= 10 mA)
Wire (24 AWG, 600 V, 150 C)
1250-2457 Triaxial Connector (female)
8121-1189 or 8150-2639 Coaxial Cable or Wire
1250-2457 Triaxial Connector (female)
8121-1191 Low Noise Coaxial Cable
1250-0118
8120-0367
BNC Connector (female)
Coaxial Cable (50 )
8150-0447 Wire
Dimensions of Connector Holes
Kelvin Triaxial Connector (in mm) Triaxial Connector (in mm)
ï ï0[
BNC Connector (in mm) Interlock Connector (in mm)
3- 28 Agilent B1500A User’s Guide, Edition 10
CAUTION
Installation
Mounting Connectors
To Make an Interlock Circuit
The interlock circuit is designed to prevent electrical shock when a user touches the measurement terminals.
You must install an interlock circuit on a shielding box to prevent hazardous voltages when the door of the shielding box is open.
Figure 3-8 shows the pin assignments of the interlock connector that should be
mounted on a connector plate or test fixture.
Interlock Connector Pin Assignments Figure 3-8
WARNING
,QWHUORFN
VZLWFK
/('
3OXJVLGHYLHZ :LULQJVLGHYLHZ
Potentially hazardous voltages may be present at the Force, Guard, and Sense terminals when the interlock terminals are shorted.
Agilent B1500A User’s Guide, Edition 10 3- 29
Figure 3-9
Installation
Mounting Connectors
Installing the interlock circuit
Install the interlock circuit as follows:
1. Mount two mechanical switches on your shielding box, so that the switches close when the door of the shielding box is closed, and open when the door is
opened. For the dimensions of the switch, see Figure 3-10 and Figure 3-11
below.
2. Mount an LED on your shielding box. For the dimensions of the LED, see
3. Use wire to connect the two switches in series between pin number 1 and 2 (or
3) of the interlock connector. See Figure 3-8.
4. Use wire to connect the LED between pin number 4 and 5 (or 6) of the interlock
If Agilent B1500A Interlock connector is connected to the interlock circuit, Agilent
B1500A SMU cannot force more than ± 42 V when the door is open. When the door is closed, it can force more than ± 42 V.
When more than ± 42 V is forced from an SMU, the LED lights to indicate high voltage output .
Dimensions of the LED (Agilent part number 1450-0641)
3- 30
8QLWV PP
Agilent B1500A User’s Guide, Edition 10
Figure 3-10
Installation
Mounting Connectors
Dimensions of the Interlock Switch (Agilent part number 3101-0302)
Figure 3-11
1&
12
& 20
8QLWVPP
Dimensions of the Interlock Switch (Agilent part number 3101-3241)
6ZLWFKRII
6ZLWFKRQ
8QLWVPP
Agilent B1500A User’s Guide, Edition 10 3- 31
Installation
Mounting Connectors
To Connect GNDU Output
The GNDU output connection examples are shown in Table 3-7
GNDU Output Connections Table 3-7
Kelvin connections
Use a low-noise coaxial cable (Agilent part number
8121-1189) from the connector to the prober, socket, or DUT as shown.
To cancel the effects of cable resistance, connect the
Sense line and Force line as close as possible to the terminal of the DUT.
non-Kelvin connections
Short the Sense and Force on the connector as shown below. Measurement data will include the residual resistance of the connection wire.
Use AWG 22 single-strand insulated wire
(Agilent part number 8150-2639) from the connector plate to the prober, socket, or DUT.
For a quick connection where measurement accuracy is not critical, connect only Force to the
DUT, without shorting the Sense and Force. With this connection, the measurement data will include residual resistance from the connection cable between the GNDU and the connector plate.
&RPPRQ
)RUFH
6HQVH
&RPPRQ
)RUFH
6HQVH
WR
'87
WR
'87
,QVXODWRU
3ODWH
7ULD[LDOFRQQHFWRU
CAUTION
&RD[LDOFDEOH
,QVXODWRU
3ODWH
7ULD[LDOFRQQHFWRU
:LUH
Use Agilent 16493L GNDU cable to connect the GNDU to your connector plate or test fixture. Do not use the triaxial cable. The GNDU is rated for up to 4.2 A, while the maximum current rating of the triaxial cable is 1 A.
3- 32 Agilent B1500A User’s Guide, Edition 10
WARNING
CAUTION
NOTE
Figure 3-12
2XWHUFRQGXFWRU
IRU*XDUGVLJQDO
Installation
Mounting Connectors
To Connect SMU Output
The SMU output connection examples are shown in Table 3-8.
Potentially hazardous voltages, up to ± 100 V (MPSMU/HRSMU) or ± 200 V
(HPSMU), are present at the Force, Sense, and Guard terminals.
To prevent electrical shock, do not expose these lines.
Before turning Agilent B1500A on, connect the Interlock terminal to an interlock circuit.
Before you touch any connections to these terminals, turn Agilent B1500A off, disconnect the power cable, and discharge any capacitors.
Never connect the Guard terminal to any output, including circuit common, chassis ground, or any other guard terminal. Doing so will damage the SMU.
Low-Noise Coaxial Cable
For the extended measurement paths over the connector plate, use low-noise coaxial cable (Agilent part number 8121-1191). This cable can maximize the guard effects and minimize the impression of the external noise.
Figure 3-12 shows the cutting example of this cable. Key point is the isolation
between the conductive layer and the center conductor. So, cut and trim the end of the cable as shown in this figure by using a cutter and so on.
Coaxial Cable Cutting Example
&RYHUKHUHXVLQJVOHHYH
,QVXODWRUEODFN
PLQPP &HQWHUFRQGXFWRU
IRU)RUFH6HQVHVLJQDO
DSSUR[WRPP
,QVXODWRUFOHDU
&RQGXFWLYHOD\HUEODFN
Agilent B1500A User’s Guide, Edition 10 3- 33
Installation
Mounting Connectors
Table 3-8 SMU Output Connections
Kelvin connections
Use low-noise coaxial cable (Agilent part number
8121-1191) from the connector to the prober, socket, or DUT as shown.
See Figure 3-13 and Figure 3-15 for the ASU and
SCUU connections respectively.
To cancel the effects of cable resistance, connect the Sense line and Force line as close as possible to the DUT terminal.
To prevent oscillations, do not use cables longer than 1.5 m. non-Kelvin connections
Use low-noise coaxial cable (Agilent part number
8121-1191). The following figure is for the connection using Kelvin triaxial cable.
For the connection using triaxial cable, connect the cable to the Force terminal only.
In this connection, measurement data will include residual resistance from the connection cable.
See Figure 3-14 and Figure 3-16 for the ASU and
SCUU connections respectively.
&RPPRQ
*XDUG
)RUFH
&RPPRQ
*XDUG
)RUFH
7ULD[LDO
FRQQHFWRU
&RPPRQ
*XDUG
6HQVH
&RD[LDOFDEOH
,QVXODWRU
3ODWH
WR
'87
7ULD[LDO
FRQQHFWRU
&RPPRQ
*XDUG
6HQVH
&RD[LDOFDEOH
,QVXODWRU
3ODWH
:LUH
WR
'87
NOTE
To Minimize Leakage Current
For the highly accurate current forcing and measurements, surround all force and sense lines by a guard as far as possible, and physically stable the cables with tape.
3- 34 Agilent B1500A User’s Guide, Edition 10
Figure 3-13
Installation
Mounting Connectors
ASU Output Kelvin Connection
*XDUG
:LUH
$68
&0+
RU)RUFH
&RPPRQ
&RD[LDOFDEOH
WR'87RU
'87KLJKWHUPLQDO
6HQVH
&085HWXUQ
&085HWXUQ
*XDUG
&0/
RU)RUFH
&RPPRQ $68
WR'87RU
'87ORZWHUPLQDO
6HQVH
*XDUG
The ASU inputs can be connected to the instruments by using a control cable, a triaxial cable, and two coaxial cables. The cables can be connected to the ASU inside the shielding box through the 16495K plate.
The ASU outputs should be connected to the DUT by using coaxial cables and wires as shown above.
When a SMU is used for the measurements, the Kelvin paths will work as same as
When a four-terminal pair (4TP) instrument is used, the sense lines can be ignored.
And a Kelvin path is used for the high signal, and the other one is used for the low signal. For the accurate impedance measurements, a wire must be connected between the ASU#1 CMU Return and the ASU#2 CMU Return.
If the 4TP instrument is not used, you can ignore the CMH, CML, CMU Return, and the DUT1 high and low terminals.
Agilent B1500A User’s Guide, Edition 10 3- 35
Figure 3-14
Installation
Mounting Connectors
ASU Output non-Kelvin Connection
$68
*XDUG
:LUH
&0+
RU)RUFH
&RPPRQ
:LUH
&RD[LDOFDEOH
$68
6HQVH
&085HWXUQ
&085HWXUQ
*XDUG
&0/
RU)RUFH
&RPPRQ
WR'87RU
'87KLJKWHUPLQDO
WR'87RU
'87ORZWHUPLQDO
6HQVH
*XDUG
The ASU inputs can be connected to the instruments by using a control cable, a triaxial cable, and two coaxial cables. The cables can be connected to the ASU inside the shielding box through the 16495K plate.
The ASU outputs should be connected to the DUT by using coaxial cables and wires as shown above.
When a SMU is used for the measurements, the Kelvin paths/force lines will work
as same as Table 3-8. Then the sense line is not extended to the DUT.
When a four-terminal pair (4TP) instrument is used, the sense lines can be ignored.
And a force line is used for the high signal, and the other one is used for the low signal. For the accurate impedance measurements, a wire must be connected between the ASU#1 CMU Return and the ASU#2 CMU Return.
If the 4TP instrument is not used, you can ignore the CMH, CML, CMU Return, and the DUT1 high and low terminals shown above.
3- 36 Agilent B1500A User’s Guide, Edition 10
Figure 3-15
Installation
Mounting Connectors
SCUU Output Kelvin Connection
*XDUG
)RUFHRU&0+
WR*6:8
&RPPRQ
*XDUG
6HQVH
WR'87RU
'87KLJKWHUPLQDO
,QVXODWRU
3ODWH
*XDUG
)RUFHRU&0/
WR*6:8
&RPPRQ
*XDUG
6HQVH
WR'87RU
'87ORZWHUPLQDO
&RD[LDOFDEOH
7ULD[LDOFRQQHFWRU
:LUH
The SCUU should be connected to the DUT by using coaxial cables and wires as shown above. Also the SCUU should be connected to the GSWU inside the shielding box by using a control cable through the 16495K plate.
When a SMU is used for the measurements, the Kelvin paths will work as same as
When the MFCMU is used, the sense lines can be ignored. And a Kelvin path is used for the CMU high, and the other one is used for the CMU low. For the accurate impedance measurements, wires must be connected to the GSWU from the CMH guard and the CML guard as near as possible to the DUT.
Agilent B1500A User’s Guide, Edition 10 3- 37
Figure 3-16
Installation
Mounting Connectors
SCUU Output non-Kelvin Connection
*XDUG
)RUFHRU&0+
WR*6:8
,QVXODWRU
3ODWH
&RPPRQ
*XDUG
6HQVH
*XDUG
)RUFHRU&0/
WR*6:8
WR'87RU
'87KLJKWHUPLQDO
WR'87RU
'87ORZWHUPLQDO
&RD[LDOFDEOH
:LUH
&RPPRQ
*XDUG
6HQVH
7ULD[LDOFRQQHFWRU
The SCUU should be connected to the DUT by using coaxial cables and wires as shown above. Also the SCUU should be connected to the GSWU inside the shielding box by using a control cable through the 16495K plate.
When a SMU is used for the measurements, the Kelvin paths/force lines will work
as same as Table 3-8. Then the sense line is not extended to the DUT.
When the MFCMU is used, the sense lines can be ignored. And a force line is used for the CMU high signal, and the other one is used for the CMU low signal. For the accurate impedance measurements, wires must be connected to the GSWU from the
CMH guard and the CML guard as near as possible to the DUT.
3- 38 Agilent B1500A User’s Guide, Edition 10
Figure 3-17
Installation
Mounting Connectors
To Connect MFCMU Output
The MFCMU output connection example is shown in Figure 3-17. This connection
is for the MFCMU without the SCUU. Then Agilent N1300A-001/002 CMU cable should be used for the connection between the MFCMU and the connectors you mount. It is ok to leave open the ground wire extended from the CMU cable.
MFCMU Output Connection
+FXU
*XDUG
+SRW
:LUH
WR'87
KLJKWHUPLQDO
,QVXODWRU
3ODWH
/SRW
WR'87
ORZWHUPLQDO
*XDUG
/FXU
%1&FRQQHFWRU
&RD[LDOFDEOH
The Hcur/Hpot/Lcur/Lpot lines should be connected to the DUT as shown above.
Use a 50 coaxial cable (Agilent part number: 8120-0367) for the
Hcur/Hpot/Lcur/Lpot lines connection. Use a wire for the guard connection.
Agilent B1500A User’s Guide, Edition 10 3- 39
NOTE
Installation
Connecting Measurement Devices
Connecting Measurement Devices
This section describes how to connect device under test (DUT) to the 16442B test fixture (B1500A-A5F), and how to connect cables to the connector plate.
If you use a wafer prober, see wafer prober manuals.
Note that you must set the module output off when connecting or disconnecting
DUTs. If not, the DUTs may be damaged.
To set the module output off, press the Stop key.
This section has the following descriptions:
•
•
Kelvin connection and non-Kelvin connection
To make the Kelvin connection, use both Force and Sense terminals. Connecting the
Force and Sense lines together at the terminal of the DUT (device under test) minimizes the measurement error caused by the residual resistance of the connection cables. The Kelvin connection is effective for the low resistance measurement and the high current measurement.
If you want to simplify the cable connections, open the Sense terminals and use the
Force terminals only. This is the non-Kelvin connection. The Force terminals can be used to force and measure dc voltage or current.
3- 40 Agilent B1500A User’s Guide, Edition 10
WARNING
CAUTION
CAUTION
Installation
Connecting Measurement Devices
Using Test Fixture
1. Press the Stop key to set the module output off.
2. Select a proper socket module for your DUT, then set the socket module on the test fixture.
3. Mount your DUT on the socket module.
4. Connect between the socket module and the test fixture by using the proper test leads.
5. Close the lid of the test fixture.
To force more than ± 42 V, close the lid of the test fixture. Otherwise, the interlock function will stop Agilent B1500A output.
To connect between the socket module and the test fixture, you can use test leads that have the following terminals:
• Miniature banana-to-miniature banana
• Miniature banana-to-pin plug
• Miniature banana-to-miniature clip
Make sure that the lid is closed properly before starting measurement. Do not perform the measurement when a test lead is protruding from the test fixture and the lid.
Do not connect or disconnect your DUT while Agilent B1500A is forcing voltage or current. Otherwise, your DUT may be damaged.
Do not touch the terminals of the test leads. Oil, perspiration, and dirt prevent good electrical contact, deteriorate insulation, and degrade measurement accuracy.
Agilent B1500A User’s Guide, Edition 10 3- 41
Installation
Connecting Measurement Devices
Connections for High Current Measurements
When you force or measure a large current, you may want to use a Kelvin (4-wire) connection to eliminate the residual resistance effects of test leads and contacts. For example, you can use the following connections as Kelvin connections on the test fixture.
Examples: Kelvin Connection
6089 $0D[
)RUFH 6HQVH )RUFH 6HQVH )RUFH
6HOHFWHG
6HQVH
*XDUG *XDUG *XDUG *XDUG *XDUG *XDUG
'UDLQ
*DWH
6XEVWUDWH
6RXUFH
To cancel the effects of the residual resistance, test leads must be connected as close as possible to the DUT.
3- 42 Agilent B1500A User’s Guide, Edition 10
WARNING
CAUTION
Installation
Connecting Measurement Devices
Using Connector Plate
This section provides the information useful for connecting cables and probing needles to a connector plate.
•
•
To Reduce Leakage Current
To reduce the leakage current caused by connection cables, the guard technique is effective. Connect the probing needles to the terminals of the connector plate by using coaxial cables as shown below:
1. At end of cable, connect coaxial center conductor to force terminal of connector plate, and connect coaxial outer conductor to guard terminal of connector plate.
2. At another end, connect coaxial center conductor to tail of the probing needle.
Never connect the outer conductor at this cable end.
Extend the outer conductor as close as possible to the probing needle.
Example
The following example connection can be used to reduce the leakage current.
Extend the outer conductor as close as possible to the probing needle. This also reduces the induced noise.
Center conductor
Outer conductor
Probing needle
Coaxial cable
Connector plate
Contact pad
Do not touch the guard terminal with bare hands because you may be shocked by high voltage. The potential of the guard terminal is equal to the output voltage.
Never connect the guard terminal to any other output, including circuit common, frame ground, or the terminals of any other unit. Doing so may damage the unit.
Agilent B1500A User’s Guide, Edition 10 3- 43
Installation
Connecting Measurement Devices
Guarding
Guarding reduces the leakage current between the measurement points and instrument. This is important when you measure low current.
The following figure shows the theory of guarding. The buffer amplifier ( 1) keeps the potential of the guard conductor at the same potential as the force conductor, so current does not flow between the force and guard conductors. Therefore, the current measured by SMU is same as current at measurement point because no current is leaked.
$
%XIIHU
*XDUG )RUFH '87
3- 44 Agilent B1500A User’s Guide, Edition 10
Installation
Connecting Measurement Devices
To Measure Low Resistance
When you measure a low resistance, high current flows through the DUT. This high current increases the measurement error caused by the residual resistance of cables.
To cancel the effect of this resistance, you can use Kelvin connections (4-wire), which means the force and sense lines are extended separately to the DUT.
Connect the probing needles to the terminals of the connector plate by using test leads or coaxial cables. Following instruction uses the coaxial cables:
1. At end of cable, connect coaxial center conductor to force terminal of connector plate, and connect coaxial outer conductor to guard terminal of connector plate.
2. At another end, connect coaxial center conductor to tail of the probing needle.
Never connect the outer conductor at this cable end.
Extend the outer conductor as close as possible to the probing needle.
3. Repeat 1 and 2 for the sense terminal of connector plate.
4. Contact the probing needles from force and sense terminals as close as possible to the DUT.
Example
The following example connection can be used to measure low resistance. The sense line is extended to the probing pad, and contacts the force line through the pad, so the voltage drop due to the residual resistance caused by cables and test leads is canceled.
Sense
Force
Center conductor
Outer conductor Probing needle
Connector plate
Coaxial cable
Contact pad
Contact pad
This example uses test leads. To reduce the leakage current, use coaxial cables.
Agilent B1500A User’s Guide, Edition 10 3- 45
Installation
Connecting Measurement Devices
Kelvin Connection
Kelvin connections give good measurement results when you force high-current.
The following figure shows the equivalent circuits for Kelvin and non-Kelvin connections.
• For the non-Kelvin connection, the voltmeter measures the voltage drop of resistances r
F1
, R
DUT
, and r
F2
.
• For the Kelvin connection, the voltmeter measures the voltage drop of resistance
R
DUT
only. The impedance of the voltmeter is very high, so the voltage drop of resistances r
S1
and r
S2
can be ignored.
5 '87 5 '87
U
)
U
) U
)
U
6
U
6
U
)
9
9 9
DQRQ.HOYLQFRQQHFWLRQ
E.HOYLQFRQQHFWLRQ
The Kelvin connection is effective even when forcing voltage. The voltage drop due to the residual resistance of the force line wiring is fed back to the voltage source via a comparator in the sense line. The input impedance of comparator is high, and current flow into the sense line is very low. So output error is not significant if the sense line wiring has a residual resistance of 10 or less. Therefore, the specified voltage appears at the sense point (point where sense line contacts force line)
3- 46 Agilent B1500A User’s Guide, Edition 10
NOTE
Installation
Capacitance Compensation When Using Switching Matrix
Capacitance Compensation When Using
Switching Matrix
When the capacitance/conductance measurement is performed through Agilent
B2200A/B2201A/E5250A switching matrix, Agilent B1500A measures the capacitance/ conductance of the path including a DUT (device under test), matrix switches, extension cables and so on. So, the data measured by the B1500A is far from the DUT’s capacitance/conductance.
Agilent EasyEXPERT provides the functions used to compensate the data measured
in the environments described in “Required Conditions” on page 3-48. This section
explains how to perform compensation.
•
•
“To Create Compensation Data File”
Corrected data by the function is not guaranteed. But typical data (supplemental data) is as follows.
Capacitance measurement accuracy (typical): ±1 % ±0.5 pF
This typical data is for the following measurement conditions:
Measurement frequency: 1 kHz to 5 MHz
Measurement range: Maximum 1000 pF
Measurement terminal: At the end of Agilent 16494A/B/C cable connected to the switch module output terminals.
The typical data does not apply to anything extended from the 16494A/B/C cable.
The conditions described in “Required Conditions” on page 3-48 must be satisfied.
Agilent B1500A User’s Guide, Edition 10 3- 47
Installation
Capacitance Compensation When Using Switching Matrix
Required Conditions
The following conditions must be satisfied to use the capacitance compensation
function. For the instrument connections, see Figure 3-18.
• Setting of the MFCMU
• Range of the measurement frequency: 1 kHz to 5 MHz
• Measurement function: Cp-G, Cp-D, Cs-Rs, or Z-Th. There is no limitation.
• Calibration
Perform the MFCMU open calibration at the end of the measurement paths in front of the switching matrix inputs. If you also perform the short calibration (optional), prepare the BNC thru adapter (Agilent part number
1250-0080, 1 ea.).
• Total cable length of both Hc-Hp side and Lc-Lp side must be the same.
• Switching matrix input ports
Use Agilent N1300A CMU cable to connect the MFCMU. The BNC-T adapters
(2 ea., Agilent part number 1250-2405 for each) are required to connect between the Hc and Hp terminals and between the Lc and Lp terminals. Connect the
Hc-Hp cable and the Lc-Lp cable as follows. It is ok to leave open the ground wire extended from the CMU cable.
Hc-Hp: Input 13 (B2200A/B2201A) or AUX INPUT CV1 (E5250A)
Lc-Lp: Input 14 (B2200A/B2201A) or AUX INPUT CV2 (E5250A)
• Switching matrix output terminals
Use the Agilent 16494A triaxial cable to extend the outputs to the connector plate or the Agilent B2220A probe card interface (only for B2200A/B2201A).
For the Kelvin connection, use the Agilent 16494B/C Kelvin triaxial cable.
• Ahead of the connector plate
Recommended cable: Agilent part number 8121-1191 Triaxial cable
You can also use another type of triaxial cable, coaxial cable, or combination of these.
To approximate the capacitance/conductance of the DUT, you need to obtain the appropriate compensation coefficients for your measurement environment, and
create your compensation data file. See Figure 3-18.
3- 48 Agilent B1500A User’s Guide, Edition 10
Installation
Capacitance Compensation When Using Switching Matrix
Figure 3-18
Agilent B1500A/MFCMU
In Figure 3-18, C1 (DATA04), C2H (DATA05), C2L (DATA06), C3H (DATA07),
C3L (DATA08) are the compensation coefficients defined in the compensation data file. where, CxH is for the path connected to the MFCMU Hc-Hp terminal, and CxL is for the path connected to the MFCMU Lc-Lp terminal.
When Agilent B2220A probe card interface is used, obtain the coefficients for C3x, and create your compensation data file. In this case, probe card will be used for the
C3x path.
When the connector plate is used, obtain the coefficients for C2x and C3x, and create your compensation data file. In this case, triaxial cable with connector plate will be used for the C2x path. And coaxial cable with positioner will be used for the
C3x path.
For obtaining the compensation coefficients and creating the compensation data file,
see “To Create Compensation Data File” on page 3-50.
Extension Cables and Compensation Coefficients
Perform open calibration at this plane.
Short calibration is optional.
Low
Agilent N1300A
+ BNC-T adapters
High to CML to CMH
Case 1. Probe card interface
Agilent 16494A/C
(C1, DATA04, fixed)
C2H, C3H, DATA05, DATA07: for CMH path
C2L, C3L, DATA06, DATA08: for CML path
Agilent B2220A (C2H, DATA05, need update)
(C2L, DATA06, need update)
Case 1 is not available for E5250A.
Probe card etc.
(C3H, DATA07, need update)
(C3L, DATA08, need update)
Case 2. Connector plate
Agilent B2200A with B2210A or
Agilent B2201A with B2211A or
Agilent E5250A with E5252A
Agilent 16494A/B
(C1, DATA04, fixed)
B2210A outputs or
B2211A outputs or
E5252A outputs
Agilent 16495F/G
Extended triaxial cables with connector plate
Extended coaxial cables and positioners
(C3H, DATA07, need update)
(C3L, DATA08, need update)
(C2H, DATA05, need update)
(C2L, DATA06, need update)
Agilent B1500A User’s Guide, Edition 10 3- 49
NOTE
Installation
Capacitance Compensation When Using Switching Matrix
To Create Compensation Data File
This section explains how to create the compensation data file. To perform the capacitance compensation, enter the file name of the compensation data file to the
User Compensation Data File field of the Extended Configuration dialog box opened from the Switching Matrix tab screen of the Configuration window.
1. Create a text file (e.g. C:\temp\c_data.txt) that contains the information as shown below.
• For B2200A/B2201A:
#
# Compensation data file for B2210A/Cable connection/3m triax cable
#
#
# MB Mother Board
# MH Matrix Path High
# ML Matrix Path Low
# C1 Agilent Triax Cable
# C2H Probe card I/F or User Triax cable High
# C2L Probe card I/F or User Triax cable Low
# C3H Probe card or User Coax cable High
# C3L Probe card or User Coax cable Low
# format version 1.0
B2210A
CABLE
#
#---------------------------------------------------
MB 0.000000e+00 5.250000e-08 2.940000e-11
MH 2.430000e+00 6.310000e-07 1.930000e-10
ML 2.490000e+00 5.970000e-07 1.920000e-10
C1 6.300000e-01 1.250000e-06 1.600000e-10
C2H 1.007000e-01
C2L 1.007000e-01
C3H 1.140000e-01
4.000000e-07
4.000000e-07
5.440000e-07
8.000000e-11
8.000000e-11
1.300000e-10
The 15th line specifies the used switch module, B2210A or B2211A.
The 16th line specifies the DUT interface, PCIF or CABLE. PCIF indicates that Agilent B2220A probe card interface is used. CABLE indicates that the connector plate is used.
The lines C2H to C3L should be modified for each measurement
environment. See Table 3-9. Do not modify the other lines.
EasyEXPERT provides the template of the compensation data file for the
B2200A/B2201A. See Table 3-11. Select and use the template suitable for your
measurement environment.
3- 50 Agilent B1500A User’s Guide, Edition 10
Table 3-9
Installation
Capacitance Compensation When Using Switching Matrix
• For E5250A:
# E5250A C Compensation coefficient data table
#
# CAUTION : Do not add or delete "REVISION" line and "DATAxx" line.
# Change the value for R,L,C of DATA05,06,07 or 08.
#
REVISION A.03.00
#
DATA00
DATA01
R [ohm]
74.65E-3
75.41E-3
L [H]
140.00E-9
90.00E-9
C [F]
58.44E-12
67.13E-12
# Frame Path 1
# Frame Path 2
DATA02
DATA03
DATA04
DATA05
DATA06
DATA07
DATA08
231.41E-3
177.56E-3
100.70E-3
100.70E-3
100.70E-3
114.00E-3
114.00E-3
450.00E-9
390.00E-9
400.00E-9
400.00E-9
400.00E-9
544.00E-9
544.00E-9
178.85E-12 # Card Path High
135.45E-12 # Card Path Low
80.00E-12
80.00E-12
80.00E-12
# Triax Cable [/m]
# User Triax Cbl H [/m]
# User Triax Cbl L [/m]
130.00E-12 # User Coax Cbl H [/m]
130.00E-12 # User Coax Cbl L [/m]
# END of Data
The lines DATA05 to DATA08 should be modified for each measurement
environment. See Table 3-9. Do not modify the other lines.
Compensation Coefficients and Modifications
Compensation coefficients
C2H
(DATA05)
C2L
(DATA06)
C3H
(DATA07)
C3L
(DATA08)
Modifications of data file
For the connector plate, change the R, L, C values in the lines.
The value must be changed to the R, L, C values of the
C2H (DATA05) path and the C2L (DATA06) path (triaxial
cable with connector plate) shown in Figure 3-18.
For Agilent B2220A probe card interface, do not modify the lines.
Change the R, L, C values in the lines. The value must be changed to the R, L, C values of the C3H (DATA07) path and
the C3L (DATA08) path shown in Figure 3-18.
For the connector plate, the coaxial cable with positioner will be the appropriate path.
For Agilent B2220A probe card interface, the probe card will be the appropriate path.
Agilent B1500A User’s Guide, Edition 10 3- 51
Installation
Capacitance Compensation When Using Switching Matrix
2. Measure the R, L, C values of the for C2H (DATA05), C2L (DATA06),
After the measurements, calculate the per meter value of the R, L, C, and record them into the following table.
Compensation coefficients
R ( )
Explanation
L (H) C (F)
C2H
(DATA05)
C2L
(DATA06)
C3H
(DATA07)
C3L
(DATA08)
3. Launch a text editor and open the compensation data file created at step 1.
Change the R, L, C values of the C2H (DATA05), C2L (DATA06),
C3H (DATA07), and C3L (DATA08) lines to the values recorded at step 2.
Do not change any other lines.
4. Save the file as your compensation data file (e.g. C:\temp\my_env_1.txt).
To perform the capacitance compensation, enter the file name of the compensation data file to the User Compensation Data File field of the Extended
Configuration dialog box, and execute the measurement.
Before starting measurement, perform the CMU calibration. For details, see
Agilent EasyEXPERT User’s Guide .
3- 52 Agilent B1500A User’s Guide, Edition 10
Table 3-10
Figure 3-19
Installation
Capacitance Compensation When Using Switching Matrix
To obtain compensation coefficients
Obtain the compensation coefficients as shown below.
1. Select the measurement frequency (Fmeas) used for the capacitance measurement of a device under test (DUT), and set it to the MFCMU. The coefficients must be measured at the same frequency.
2. Perform the MFCMU open calibration at the measurement terminal. Optionally, perform short calibration if you want.
3. See Table 3-10 and Figure 3-19, and set the MFCMU.
4. Connect the path/cable corresponding to C3H (DATA07) shown in Figure 3-18
to the MFCMU. Then measure and record the R, L, and C values.
5. Connect the path/cable corresponding to C3L (DATA08) to the MFCMU. Then measure and record the R, L, and C values.
6. If you use the connector plate, perform the following procedure. a. Connect the path/cable corresponding to C2H (DATA05) to the MFCMU.
Then measure and record the R, L, and C values.
b. Connect the path/cable corresponding to C2L (DATA06) to the MFCMU.
Then measure and record the R, L, and C values.
R, L, C Measurement Conditions
Parameter
R
L
Frequency
1 kHz to 5 MHz a
Function
SERIES
Terminals
A and B see note b
A and C C PARALLEL a. R, L, C of all coefficients must be measured with the same frequency setting.
b. For triaxial cable, connect B to F directly, and measure L between A and E.
For coaxial cable, ignore E and F, and connect B to D directly, and measure
L between A and C.
Compensation Coefficient Measurement Terminals of Extended Cables
*8$5'& *5281'( *5281') *8$5''
,QVXODWRU
7ULD[LDO&DEOH
)25&(RU6(16($
)25&(RU6(16(%
Agilent B1500A User’s Guide, Edition 10 3- 53
Installation
Capacitance Compensation When Using Switching Matrix
Table 3-11 Template Compensation Data Files for B2200A/B2201A
Measurement environment that template targets
File name a
Switch module
Cable b
DUT interface c
Coefficients to be modified
<path>\b2210a\pcif\triax\3m.data
<path>\b2210a\pcif\triax\4m.data
<path>\b2210a\pcif\kelvin\3m.data
<path>\b2210a\pcif\kelvin\4m.data
<path>\b2210a\cable\triax\1_5m.data
<path>\b2210a\cable\triax\3m.data
<path>\b2210a\cable\triax\4m.data
<path>\b2210a\cable\kelvin\1_5m.data
B2210A 16494A-002
16494A-005
16494C-002
16494C-005
B2220A C3H and C3L
16494A-001 16495F/G C2H, C2L,
16494A-002
C3H, and C3L
16494A-005
16494B-001
16494B-002
16494C-005
<path>\b2210a\cable\kelvin\3m.data
<path>\b2210a\cable\kelvin\4m.data
<path>\b2211a\pcif\triax\3m.data
<path>\b2211a\pcif\triax\4m.data
<path>\b2211a\pcif\kelvin\3m.data
<path>\b2211a\pcif\kelvin\4m.data
<path>\b2211a\cable\triax\1_5m.data
<path>\b2211a\cable\triax\3m.data
B2211A 16494A-002
16494A-005
16494C-002
16494C-005
B2220A C3H and C3L
16494A-001 16495F/G C2H, C2L,
16494A-002
C3H, and C3L
<path>\b2211a\cable\triax\4m.data
<path>\b2211a\cable\kelvin\1_5m.data
<path>\b2211a\cable\kelvin\3m.data
<path>\b2211a\cable\kelvin\4m.data
16494A-005
16494B-001
16494B-002
16494C-005 a. <path>: \Program Files\Agilent\B1500\EasyEXPERT\B220xA\ccdata b. Model number of the cable connected between the switch module and the DUT interface.
c. Agilent B2220A probe card interface or Agilent 16495F/G connector plate.
3- 54 Agilent B1500A User’s Guide, Edition 10
NOTE
Installation
Maintenance
Maintenance
Maintenance should be performed periodically to keep Agilent B1500A in good condition.
Cleaning
Before performing cleaning, turn off the instrument, and disconnect power cable from the rear panel. Use a dry cloth to clean the external case parts.
To prevent electrical shock, do not perform cleaning when the instrument is turned on, and do not use a wet cloth.
Self-test and Diagnostics
Agilent B1500A provides the following functions to check the operation. Perform the following functions as necessary. Open the measurement terminals to perform self-test, self-calibration, or diagnostics.
• Self-test
• Self-calibration
• Diagnostics
If problems arise, contact Agilent Technologies. For details, see Agilent
EasyEXPERT User’s Guide .
Interlock Open/Close test and High Voltage LED test
Interlock function limits the SMU maximum output voltage to ± 42 V when the measurement terminal is touchable. For safety, this function must be checked before using the B1500A after power on at least once a day by performing the diagnostics.
Calibration
Calibration and adjustments must be performed periodically so that the instruments satisfy the specifications, and keep a good condition. It is recommended to perform the calibration once a year at least. For the calibration and adjustments, contact
Agilent Technologies. Trained service personnel will perform the calibration and adjustments. Also see Agilent EasyEXPERT User’s Guide .
Agilent B1500A User’s Guide, Edition 10 3- 55
WARNING
NOTE
NOTE
Installation
About Plug-in Modules
About Plug-in Modules
Agilent Technologies is responsible for the module installation of Agilent B1500A.
Contact Agilent Technologies for the module installation. Then send the following equipment and accessories to Agilent Technologies.
• B1500A
• Plug-in modules to be installed
• ASU, for installing the exclusive HRSMU or retrofitting ASU only
• Connection cable between ASU and HRSMU, for installing the exclusive
HRSMU or retrofitting ASU only
• RSU, for installing WGFMU
• Connection cable between RSU and WGFMU, for installing WGFMU
For returning ASU or RSU, do not forget to notify the combination of the unit, connection cable, and module channel.
To prevent electrical shock, turn off Agilent B1500A and remove the power cable before removing the connection cables.
About B1500A which supports SPGU and WGFMU
SPGU and WGFMU are supported by the B1500A serial numbered JP40N xxxxx and later. The other B1500A needs the mainframe upgrade to support the module.
Contact Agilent Technologies to upgrade the B1500A.
Module locations after servicing
After the module installation, upgrade, and so on, the B1500A will be returned with
the module configuration decided by the rule shown in Table 3-12. If you want to
change the module locations, consult the service personnel before servicing.
3- 56 Agilent B1500A User’s Guide, Edition 10
Table 3-12
Installation
About Plug-in Modules
Module Type and Locations
Module locations when the B1500A is shipped from the factory are shown in Table
3-12. This table shows the relative locations by the module types.
If the SPGUs are installed, the SPGUs must be installed in the slots from the slot number 1. And if the SPGU and the WGFMU are not installed and the HPSMUs are installed, the HPSMUs must be installed in the slots from the slot number 1. Then the same type of modules must be installed in the contiguous slots.
For example, if the module configuration is two HPSMU, two MPSMU, and one
CMU, the B1500A will be shipped with the HPSMUs of the slots 1 to 4, the
MPSMUs of the slots 5 to 6, the CMU of the slot 7, and the blank panels of the slots
8 to 10.
Module Installation Rule
Slot Number and Location
1
:
:
:
:
:
:
10
:
0
:
:
:
: top
:
:
:
:
: bottom
Module Type
B1520A Multi Frequency CMU
B1511A Medium Power SMU
B1517A High Resolution SMU
B1510A High Power SMU
B1530A WGFMU
B1525A High Voltage SPGU
GNDU/ADC (always installed)
Agilent B1500A User’s Guide, Edition 10 3- 57
Installation
About Plug-in Modules
3- 58 Agilent B1500A User’s Guide, Edition 10
4 Specifications
Specifications
This chapter describes the specifications and supplemental information for Agilent
B1500A Semiconductor Device Analyzer and its associated modules.
The specifications are the standards against which the B1500A and its associated modules are tested. When the B1500A and any of its associated modules are shipped from the factory, they meet the specifications. The “supplemental” information and
“typical” entries in the following specifications are not warranted, but provide useful information about the functions and performance of the instrument.
This chapter contains the following sections.
•
•
•
•
•
•
•
•
“SMU Supplemental Information”
•
•
•
•
•
•
•
•
•
4- 2 Agilent B1500A User’s Guide, Edition 10
NOTE
Specifications
Hardware
Hardware
Specification Conditions
The measurement and output accuracy are specified at the rear panel connector terminals when referenced to the Zero Check terminal. The B1530A WGFMU measurement and output accuracy are specified at the output terminal of the RSU.
Accuracy is specified under the following conditions:
1. Temperature: 23 C ± 5 C
2. Humidity: 20 % to 60 %
3. After 40 minutes warm-up followed by self-calibration
4. Ambient temperature change less than ± 1 C after self-calibration execution, not applicable for MFCMU and WGFMU
5. Measurement made within one hour after self-calibration execution, not applicable for MFCMU and WGFMU
6. Calibration period: 1 year
7. SMU integration time setting:
1 PLC (1 nA to 1 A range, voltage range)
20 PLC (100 pA range)
50 PLC (1 pA to 10 pA range)
Averaging of high speed ADC: 128 samples per 1 PLC
8. SMU filter: ON
9. SMU measurement terminal connection: Kelvin connection
10. WGFMU load capacitance: 25 pF or less
Agilent Technologies is responsible for removing, installing, and replacing the
B1500A modules. Contact your nearest Agilent Technologies to install and calibrate the B1500A modules.
Agilent B1500A User’s Guide, Edition 10 4- 3
Specifications
Hardware
Mainframe
The B1500A supports ten slots for plug-in modules.
Module
B1510A HPSMU
B1511A MPSMU
B1517A HRSMU
E5288A ASU a
Slots occupied
2
1
1
-
Range of operation
200 V to 200 V,
1A to 1 A
100 V to 100 V,
100 mA to 100 mA
100 V to 100 V,
100 mA to 100 mA
100 V to 100 V,
100 mA to 100 mA
1 kHz to 5 MHz
2
Measurement resolution
0.5
0.5
0.5
V, 10 fA
V, 10 fA
V, 1 fA
V, 0.1 fA
B1520A MFCMU
B1525A HV-SPGU
B1530A WGFMU
1
1
1
± 40 V (80 Vp-p)
3 V to 3 V,
5 V to 5 V,
0 V to 10 V,
10 V to 0 V c
0.035 fFrms b
50 V
0.014 % of the range d a. The E5288A Atto Sense and Switch Unit (ASU) is connected with the
B1517A High Resolution SMU (HRSMU).
b. Dispersion of measurement values when connecting a DUT 10 pF to the measurement terminals under the measurement condition of frequency
1 MHz, signal level 250 mVac, and measurement time 1 PLC. The display resolution is 0.000001 fF at 1 fF order by 6 digits display.
c. Fast IV mode supports 0 to ± 10 V not supported by PG mode.
d. Display resolution
4- 4 Agilent B1500A User’s Guide, Edition 10
Specifications
Hardware
• Maximum module configuration
The B1500A can contain any combination of modules.
Allowable number of modules installed in one mainframe (each/mainframe):
HPSMU 4, MPSMU 10, HRSMU 10, MFCMU 1, HV-SPGU 5, WGFMU 5
If the B1500A contains the WGFMU, sum of Rating for all module types in the mainframe must be < 60.
where Rating = Number of modules Rating for each module type
Rating for each module type: HPSMU 14, MPSMU 2, HRSMU 2, MFCMU 7,
HV-SPGU 12, WGFMU 10
• Maximum voltage between common and ground
± 42 V
• Ground unit (GNDU)
The GNDU is furnished standard with the mainframe.
• Output voltage: 0 V ± 100 V
• Maximum sink current: ± 4.2 A
• Output terminal/connection: Triaxial connector, Kelvin (remote sensing)
• Load capacitance: 1 F, supplemental information
• Cable resistance: supplemental information
Terminal
Sense
Force
Cable resistance
10
< 1 (Is 1.6 A)
< 0.7 (1.6 A < Is 2.0 A)
< 0.35 (2.0 A < Is 4.2 A) where Is is the current being sunk by the GNDU.
Agilent B1500A User’s Guide, Edition 10 4- 5
Specifications
Hardware
MPSMU/HRSMU
MPSMU: Medium Power Source/Monitor Unit
HRSMU: High Resolution Source/Monitor Unit
• Voltage range, resolution, and accuracy
See Table 4-1 for high resolution ADC and Table 4-3 for high speed ADC.
• Current range, resolution, and accuracy
See Table 4-2 for high resolution ADC and Table 4-4 for high speed ADC.
Specified measurement resolution is limited by fundamental noise limits.
Minimum displayed resolution is 1 aA at 1 pA range by 6 digits. Measurements made in the lower ranges can be greatly impacted by vibrations and shocks.
These specifications assume an environment free of these factors.
• Power consumption
Voltage source mode:
Voltage range (V)
0.5
2
5
20
40
100
Power consumption a
(W)
Ic 20
Ic 20
Ic 20
Ic 20
Ic 40
Ic 100 a. Ic is the current compliance setting.
Current source mode:
Voltage compliance a
(V)
Vc 20
20 < Vc 40
40 < Vc 100
Power consumption
Io
Io
Io a. Vc is the voltage compliance setting.
b. Io is the output current.
20
40
100 b
(W)
4- 6 Agilent B1500A User’s Guide, Edition 10
Specifications
Hardware
Table 4-1 Voltage range, resolution, and accuracy (high resolution ADC)
Range
Force resolution
Measurement resolution
Force accuracy
± (%+mV) a
Measurement accuracy
± (%+mV) a
±0.5 V
±2 V
±5 V
±20 V
±40 V
±100 V
25 V
100 V
250 V
1 mV
2 mV
5 mV
0.5 V
2 V
5 V
20 V
40 V
100 V
±
±
±
(0.018 + 0.15)
(0.018 + 0.4)
(0.018 + 0.75)
±
±
±
(0.018 + 3)
(0.018 + 6)
(0.018 + 15)
±
±
±
±
±
(0.01 + 0.12)
(0.01 + 0.14)
(0.009 + 0.25)
(0.009 + 0.9)
± (0.01 + 1)
(0.012 + 2.5) a.
± (% of output/measured value + offset value in mV) b. 100 mA (Vo 20 V), 50 mA (20 V < Vo 40 V), 20 mA (40 V < Vo), Vo is the output voltage.
Maximum current
100 mA
100 mA
100 mA
100 mA b
Table 4-2 Current range, resolution, and accuracy (high resolution ADC)
Range
±1 pA b
±10 pA c
±100 pA c
±1 nA
±10 nA
±100 nA
±1 A
±10 A
±100 A
±1 mA
±10 mA
±100 mA
Force resolution
1 fA
5 fA
5 fA
50 fA
500 fA
5 pA
50 pA
500 pA
5 nA
50 nA
500 nA
5 A
Measurement resolution
0.1 fA
0.4 fA b
/ 1 fA
0.5 fA b
/ 2 fA
10 fA
10 fA
100 fA
1 pA
10 pA
100 pA
1 nA
10 nA
100 nA
Force accuracy ± (%+A+A) a
± (0.9+15E-15)
± (0.46+3E-14+Vo E-17)
± (0.3+1E-13+Vo E-16)
± (0.1+3E-13+Vo 1E-15)
± (0.1+3E-12+Vo 1E-14)
± (0.05+3E-11+Vo 1E-13)
± (0.05+3E-10+Vo 1E-12)
± (0.05+3E-9+Vo 1E-11)
± (0.035+15E-9+Vo 1E-10)
± (0.04+15E-8+Vo 1E-9)
± (0.04+15E-7+Vo 1E-8)
± (0.045+15E-6+Vo 1E-7)
Measurement accuracy
± (%+A+A) a
± (0.9+12E-15)
± (0.46+15E-15+Vo 1E-17)
± (0.3+3E-14+Vo 1E-16)
± (0.1+2E-13+Vo 1E-15)
± (0.1+1E-12+Vo 1E-14)
± (0.05+2E-11+Vo 1E-13)
± (0.05+1E-10+Vo 1E-12)
± (0.04+2E-9+Vo 1E-11)
± (0.03+3E-9+Vo 1E-10)
± (0.03+6E-8+Vo 1E-9)
± (0.03+2E-7+Vo 1E-8)
± (0.04+6E-6+Vo 1E-7)
Maximum voltage
100 V
100 V
100 V
100 V
100 V
100 V
100 V
100 V
100 V
100 V
100 V d a.
± (% of output/measured value + fixed offset in A + proportional offset in A), Vo is the output voltage in V.
b. Available when Agilent E5288A Atto Sense and Switch Unit (ASU) is used.
c. Available for HRSMU.
d. 100 V (Io 20 mA), 40 V (20 mA < Io 50 mA), 20 V (50 mA < Io), Io is the output current.
Agilent B1500A User’s Guide, Edition 10 4- 7
Specifications
Hardware
Table 4-3 Voltage range, resolution, and accuracy (high speed ADC)
Range
±0.5 V
±2 V
±5 V
±20 V
±40 V
±100 V
Force resolution
25 V
100 V
250 V
1 mV
2 mV
5 mV
Measurement resolution
25 V
100 V
250 V
1 mV
2 mV
5 mV
Force accuracy
± (%+mV) a
± (0.018 + 0.15)
± (0.018 + 0.4)
± (0.018 + 0.75)
± (0.018 + 3)
± (0.018 + 6)
± (0.018 + 15)
Measurement accuracy
±
±
± (%+mV) a
(0.01 + 0.25)
±
±
±
±
(0.01 + 0.7)
(0.01 + 2)
(0.01 + 4)
(0.015 + 8)
(0.02 + 20) a.
± (% of output/measured value + offset value in mV) b. 100 mA (Vo 20 V), 50 mA (20 V < Vo 40 V), 20 mA (40 V < Vo), Vo is the output voltage.
Maximum current
100 mA
100 mA
100 mA
100 mA b
Table 4-4 Current range, resolution, and accuracy (high speed ADC)
Range
±1 pA b
±10 pA c
±100 pA c
±1 nA
±10 nA
±100 nA
±1 A
±10 A
±100 A
±1 mA
±10 mA
±100 mA
Force resolution
1 fA
5 fA
5 fA
50 fA
500 fA
5 pA
50 pA
500 pA
5 nA
50 nA
500 nA
5 A
Measurement resolution
0.1 fA
1 fA
5 fA
50 fA
500 fA
5 pA
50 pA
500 pA
5 nA
50 nA
500 nA
5 A
Force accuracy ± (%+A+A)
± (0.9+15E-15)
± (0.46+3E-14+Vo E-17)
± (0.3+1E-13+Vo E-16)
± (0.1+3E-13+Vo 1E-15)
± (0.1+3E-12+Vo 1E-14)
± (0.05+3E-11+Vo 1E-13)
± (0.05+3E-10+Vo 1E-12)
± (0.05+3E-9+Vo 1E-11)
± (0.035+15E-9+Vo 1E-10)
± (0.04+15E-8+Vo 1E-9)
± (0.04+15E-7+Vo 1E-8)
± (0.045+15E-6+Vo 1E-7) a
Measurement accuracy
± (%+A+A) a
± (1.8+12E-15)
± (0.5+15E-15+Vo 1E-17)
± (0.5+4E-14+Vo 1E-16)
± (0.25+3E-13+Vo 1E-15)
± (0.25+2E-12+Vo 1E-14)
± (0.1+2E-11+Vo 1E-13)
± (0.1+2E-10+Vo 1E-12)
± (0.05+2E-9+Vo 1E-11)
± (0.05+2E-8+Vo 1E-10)
± (0.04+2E-7+Vo 1E-9)
± (0.04+2E-6+Vo 1E-8)
± (0.1+2E-5+Vo 1E-7) a.
± (% of output/measured value + fixed offset in A + proportional offset in A), Vo is the output voltage in V.
b. Available when Agilent E5288A Atto Sense and Switch Unit (ASU) is used.
c. Available for HRSMU.
d. 100 V (Io 20 mA), 40 V (20 mA < Io 50 mA), 20 V (50 mA < Io), Io is the output current.
Maximum voltage
100 V
100 V
100 V
100 V
100 V
100 V
100 V
100 V
100 V
100 V
100 V d
4- 8 Agilent B1500A User’s Guide, Edition 10
NOTE
NOTE
Specifications
Hardware
ASU
ASU: Atto Sense and Switch Unit
• Maximum voltage, AUX path
100 V (AUX input to AUX common)
100 V (AUX input to circuit common)
42 V (AUX common to circuit common)
• Maximum current, AUX path
0.5 A (AUX input to Force output)
• Band width (at -3 dB), AUX port
30 MHz, supplemental information
Connect ASU to dedicated HRSMU
The specifications are satisfied and guaranteed for the exclusive combination of the
ASU and the HRSMU. So confirm the serial number of the ASU and connect it to the dedicated HRSMU properly.
Connection path control
Disable source output of the SMU and other instrument connected to the ASU inputs before controlling the ASU connection path.
Agilent B1500A User’s Guide, Edition 10 4- 9
Specifications
Hardware
HPSMU
HPSMU: High Power Source/Monitor Unit
• Voltage range, resolution, and accuracy
See Table 4-5 for high resolution ADC and Table 4-7 for high speed ADC.
• Current range, resolution, and accuracy
See Table 4-6 for high resolution ADC and Table 4-8 for high speed ADC.
Specified measurement resolution is limited by fundamental noise limits.
• Power consumption
Voltage source mode:
Voltage range (V) Power consumption a (W)
2
20
40
100
200 a. Ic is the current compliance setting.
Ic 20
Ic 20
Ic 40
Ic 100
Ic 200
Current source mode:
Voltage compliance a (V) Power consumption b (W)
Vc 20
20 < Vc 40
40 < Vc 100
100 < Vc 200 a. Vc is the voltage compliance setting.
b. Io is the output current.
Io 20
Io 40
Io 100
Io 200
4- 10 Agilent B1500A User’s Guide, Edition 10
Specifications
Hardware
Table 4-5 Voltage range, resolution, and accuracy (high resolution ADC)
Range
Force resolution
Measurement resolution
Force accuracy
± (%+mV) a
±2 V
±20 V
±40 V
±100 V
±200 V
100 V
1 mV
2 mV
5 mV
10 mV
2 V
20 V
40 V
100 V
200 V
± (0.018 + 0.4)
± (0.018 + 3)
± (0.018 + 6)
± (0.018 + 15)
± (0.018 + 30) a.
± (% of output/measured value + offset value in mV)
Measurement accuracy
± (%+mV) a
± (0.01 + 0.14)
± (0.01 + 0.14)
± (0.01 + 1)
± (0.012 + 2.5)
± (0.014 + 2.8)
Maximum current
1 A
1 A
500 mA
125 mA
50 mA
Table 4-6 Current range, resolution, and accuracy (high resolution ADC)
Range
Force resolution
Measurement resolution
Force accuracy ± (%+A+A) a
Measurement accuracy
± (%+A+A) a
Maximum voltage
±1 nA
±10 nA
±100 nA
±1 A
±10 A
±100 A
±1 mA
±10 mA
±100 mA
±1 A
50 fA
500 fA
5 pA
50 pA
500 pA
5 nA
50 nA
500 nA
5 A
50 A
10 fA
10 fA
100 fA
1 pA
10 pA
100 pA
1 nA
10 nA
100 nA
1 A
± (0.1+3E-13+Vo 1E-15)
± (0.1+3E-12+Vo 1E-14)
± (0.05+3E-11+Vo E-13)
± (0.05+3E-10+Vo E-12)
± (0.05+3E-9+Vo 1E-11)
± (0.035+15E-9+Vo E-10)
± (0.04+15E-8+Vo 1E-9)
± (0.04+15E-7+Vo E-8)
± (0.045+15E-6+Vo E-7)
± (0.4+3E-4+Vo E-6)
± (0.1+3E-13+Vo 1E-15)
± (0.1+25E-13+Vo 1E-14)
± (0.05+25E-12+Vo 1E-13)
± (0.05+1E-10+Vo 1E-12)
± (0.04+2E-9+Vo 1E-11)
± (0.03+3E-9+Vo 1E-10)
± (0.03+6E-8+Vo 1E-9)
± (0.03+2E-7+Vo 1E-8)
± (0.04+6E-6+Vo 1E-7)
± (0.4+15E-5+Vo 1E-6)
200 V a.
± (% of output/measured value + fixed offset in A + proportional offset in A), Vo is the output voltage in V.
b. 200 V (Io 50 mA), 100 V (50 mA < Io 125 mA), 40 V (125 mA < Io 500 mA),
20 V (500 mA < Io 1 A), Io is the output current.
200 V
200 V
200 V
200 V
200 V
200 V
200 V b
Agilent B1500A User’s Guide, Edition 10 4- 11
Specifications
Hardware
Table 4-7 Voltage range, resolution, and accuracy (high speed ADC)
Range
Force resolution
Measurement resolution
Force accuracy
± (%+mV) a
±2 V
±20 V
±40 V
±100 V
±200 V
100 V
1 mV
2 mV
5 mV
10 mV
100 V
1 mV
2 mV
5 mV
10 mV
± (0.018 + 0.4)
± (0.018 + 3)
± (0.018 + 6)
± (0.018 + 15)
± (0.018 + 30) a.
± (% of output/measured value + offset value in mV)
Measurement accuracy
± (%+mV) a
± (0.01 + 0.7)
± (0.01 + 4)
± (0.015 + 8)
± (0.02 + 20)
± (0.035 + 40)
Maximum current
1 A
1 A
500 mA
125 mA
50 mA
Table 4-8 Current range, resolution, and accuracy (high speed ADC)
Range
Force resolution
Measurement resolution
Force accuracy ± (%+A+A) a
Measurement accuracy
± (%+A+A) a
Maximum voltage
±1 nA
±10 nA
±100 nA
±1 A
±10 A
±100 A
±1 mA
±10 mA
±100 mA
50 fA
500 fA
5 pA
50 pA
500 pA
5 nA
50 nA
500 nA
5 A
50 A
50 fA
500 fA
5 pA
50 pA
500 pA
5 nA
50 nA
500 nA
5 A
50 A
± (0.1+3E-13+Vo 1E-15)
± (0.1+3E-12+Vo 1E-14)
± (0.05+3E-11+Vo E-13)
± (0.05+3E-10+Vo E-12)
± (0.05+3E-9+Vo 1E-11)
± (0.035+15E-9+Vo E-10)
± (0.04+15E-8+Vo 1E-9)
± (0.04+15E-7+Vo E-8)
± (0.045+15E-6+Vo E-7)
± (0.4+3E-4+Vo E-6)
± (0.25+3E-13+Vo 1E-15)
± (0.25+2E-12+Vo 1E-14)
± (0.1+2E-11+Vo 1E-13)
± (0.1+2E-10+Vo 1E-12)
± (0.05+2E-9+Vo 1E-11)
± (0.05+2E-8+Vo 1E-10)
± (0.04+2E-7+Vo 1E-9)
± (0.04+2E-6+Vo 1E-8)
± (0.1+2E-5+Vo 1E-7)
± (0.5+3E-4+Vo 1E-6)
200 V
200 V
200 V
200 V
200 V
200 V
200 V
200 V
±1 A a.
± (% of output/measured value + fixed offset in A + proportional offset in A), Vo is the output voltage in V.
b. 200 V (Io 50 mA), 100 V (50 mA < Io 125 mA), 40 V (125 mA < Io 500 mA),
20 V (500 mA < Io 1 A), Io is the output current.
b
4- 12 Agilent B1500A User’s Guide, Edition 10
Specifications
Hardware
SMU Common Specifications
• Output terminal/connection
Dual triaxial connector, Kelvin (remote sensing)
• Voltage/current compliance (limiting)
The SMU can limit output voltage or current to prevent damaging the device under test.
• Voltage compliance:
0 V to ± 100 V (MPSMU, HRSMU)
0 V to ± 200 V (HPSMU)
• Current compliance:
± 10 fA to ± 100 mA (HRSMU with ASU)
± 100 fA to ± 100 mA (HRSMU)
± 1 pA to ± 100 mA (MPSMU)
± 1 pA to ± 1 A (HPSMU)
• Compliance accuracy:
Same as the current or voltage set accuracy.
• Pulsed measurement
• Width: 500 s to 2 s
• Period: 5 ms to 5 s
Period Width+2 ms (when Width 100 ms)
Period Width+10 ms (when Width > 100 ms)
• Resolution: 100 s
• Pulse setting accuracy (fixed measurement range), supplemental information
• Width: 0.5 % + 50 s
• Period: 0.5 % + 100 s
Agilent B1500A User’s Guide, Edition 10 4- 13
Specifications
Hardware
• About measurement accuracy
• RF electromagnetic field and SMU measurement accuracy
Voltage and current measurement accuracy may be affected by RF electromagnetic field of strength over 3 V/m at frequencies 80 MHz to
1 GHz and 1.4 GHz to 2.0 GHz, and 1 V/m at frequencies 2.0 GHz to 2.7
GHz. The extent of this effect depends upon how the instrument is positioned and shielded.
• Induced RF field noise and SMU measurement accuracy
Voltage and current measurement accuracy can be affected by induced RF field noise strengths greater than 3Vrms in the frequency range of 150 kHz to 80 MHz. The extent of this effect depends upon how the instrument is positioned and shielded.
SMU Supplemental Information
• Maximum allowable cable resistance (Kelvin connection)
Sense: 10
Force: 10 ( 100 mA), 1.5 ( > 100 mA)
• Voltage source output resistance (Force line, Non-Kelvin connection)
0.2 (HPSMU)
0.3 (MPSMU, HRSMU)
• Voltage measurement input resistance: 10 13
• Current source output resistance: 10 13 (at 1 nA range)
• Current compliance setting accuracy (for opposite polarity)
For 1 pA to 10 nA ranges: Setting accuracy ± 12 % of range
For 100 nA to 1 A ranges: Setting accuracy ± 2.5 % of range
• Maximum capacitive load
For 1 pA to 10 nA ranges: 1000 pF
For 100 nA to 10 mA ranges: 10 nF
For 100 mA and 1 A ranges: 100 F
4- 14 Agilent B1500A User’s Guide, Edition 10
Specifications
Hardware
• Maximum guard capacitance
900 pF (HPSMU, MPSMU, HRSMU)
660 pF (HRSMU with ASU)
• Maximum shield capacitance
5000 pF (HPSMU, MPSMU, HRSMU)
3500 pF (HRSMU with ASU)
• Maximum guard offset voltage
± 1 mV (HPSMU)
± 3 mV (MPSMU, HRSMU)
± 4.2 mV (HRSMU with ASU, Iout 100 A)
• Noise characteristics (filter ON)
Voltage source: 0.01 % of V range (rms.)
Current source: 0.1 % of I range (rms.)
• Overshoot (filter ON), typical
Voltage source: 0.03 % of V range
Current source: 1 % of I range
• Range switching transient noise (filter ON)
Voltage ranging: 250 mV
Current ranging: 70 mV
• Slew rate: 0.2 V/ s (maximum)
• Voltage range, resolution, and accuracy (high speed ADC)
• Current range, resolution, and accuracy (high speed ADC)
Specified measurement resolution is limited by fundamental noise limits.
Minimum displayed resolution is 1 aA at 1 pA range by 6 digits.
Measurements made in the lower ranges can be greatly impacted by vibrations and shocks. These specifications assume an environment free of these factors.
Agilent B1500A User’s Guide, Edition 10 4- 15
Specifications
Hardware
Table 4-9 Voltage range, resolution, and accuracy (high speed ADC), supplemental information
Range
Measurement resolution
Measurement accuracy
± (%+mV) a
Range
Measurement resolution
Measurement accuracy
± (%+mV) a
±0.5 V b 25 V ± (0.01 + 0.25) ±40 V 2 mV
±2 V
±5 V b
±20 V
100 V
250
1 mV
V
± (0.01 + 0.7)
± (0.01 + 2)
± (0.01 + 4)
±100 V
±200 V c
5 mV
10 mV a.
± (% of reading + offset value in mV). Averaging is 128 samples in 1 PLC.
b. Available for MPSMU/HRSMU.
c. Available for HPSMU.
±
±
±
(0.015 + 8)
(0.02 + 20)
(0.035 + 40)
Table 4-10 Current range, resolution, and accuracy (high speed ADC), supplemental information
Range
Measurement resolution
Measurement accuracy
± (%+A+A) a
Range
Measurement resolution
Measurement accuracy
± (%+A+A) a
±1 pA b 0.1 fA ± (1.8+12E-15) ±10 A 500 pA ± (0.04+2E-9+Vo 1E-11)
±10 pA c 1 fA ± (0.5+15E-15+Vo 1E-17) ±100 A 5 nA ± (0.03+2E-8+Vo 1E-10)
±100 pA c
±1 nA
±10 nA
±100 nA
5 fA
50 fA
500 fA
5 pA
± (0.3+3E-14+Vo 1E-16)
± (0.1+3E-13+Vo 1E-15)
± (0.1+2E-12+Vo 1E-14)
± (0.05+2E-11+Vo 1E-13)
±1 mA
±10 mA
±100 mA
50 nA
500 nA
5 A
50 A
± (0.03+2E-7+Vo 1E-9)
± (0.03+2E-6+Vo 1E-8)
± (0.04+2E-5+Vo 1E-7)
± (0.4+3E-4+Vo 1E-6)
±1 A d
±1 A 50 pA ± (0.05+2E-10+Vo 1E-12) a.
± (% of reading + fixed offset in A + proportional offset in A), Vo is the output voltage in V.
b. Available when Agilent E5288A Atto Sense and Switch Unit (ASU) is used.
c. 10 pA and 100 pA ranges are available for HRSMU with or without ASU.
d. Available for HPSMU.
4- 16 Agilent B1500A User’s Guide, Edition 10
Specifications
Hardware
MFCMU
MFCMU: Multi Frequency Capacitance Measurement Unit
• Measurement functions
• Measurement parameters: Cp-G, Cp-D, Cp-Q, Cp-Rp, Cs-Rs, Cs-D, Cs-Q,
Lp-G, Lp-D, Lp-Q, Lp-Rp, Ls-Rs, Ls-D, Ls-Q, R-X, G-B, Z , Y
• Ranging: Auto or fixed
• Measurement terminal: Four-terminal pair configuration, four BNC (female) connectors
• Cable length: 1.5 m or 3 m, automatic identification of accessories
• Test signal
• Frequency
Range: 1 kHz to 5 MHz
Resolution: 1 mHz (minimum)
Accuracy: ± 0.008 %
• Output signal level
Range: 10 mVrms to 250 mVrms
Resolution: 1 mVrms
Accuracy:
± (10.0 % + 1 mVrms) at the measurement port of the MFCMU
± (15.0 % + 1 mVrms) at the measurement port of the MFCMU cable (1.5 m or 3.0 m)
• Output impedance: 50 , typical
• Signal level monitor
Range: 10 mVrms to 250 mVrms
Accuracy (open load):
± (10.0 % of reading + 1 mVrms) at the measurement port of the MFCMU
± (15.0 % of reading + 1 mVrms) at the measurement port of the MFCMU cable (1.5 m or 3.0 m)
Agilent B1500A User’s Guide, Edition 10 4- 17
Specifications
Hardware
• DC bias function
• DC bias
Range: 0 to ± 25 V
Resolution: 1 mV
Accuracy: ± (0.5 % + 5.0 mV) at the measurement port of the MFCMU or the MFCMU cable (1.5 m or 3.0 m)
• Maximum DC bias current, supplemental information:
Impedance range ( )
50
100
300
1 10
3
3 10
3
10 10
3
30 10
3
100 10
3
300 10
3
Maximum DC bias current (A)
10 10
-3
10 10
-3
10 10
-3
1 10
-3
1 10
-3
100 10
-6
100 10
-6
10 10
-6
10 10
-6
• Output impedance: 50 , typical
• DC bias monitor
Range: 0 to ± 25 V
Accuracy (open load): ± (0.2 % of reading + 10 mV) at the measurement port of the MFCMU or the MFCMU cable (1.5 m or 3.0 m)
• Sweep characteristics
• Available sweep parameters: DC bias voltage, oscillator level, frequency
• Sweep type: linear, log
• Sweep mode: single, double
• Sweep direction: up, down
• Number of measurement points: maximum 1001
4- 18 Agilent B1500A User’s Guide, Edition 10
Specifications
Hardware
• Measurement accuracy
Measurement accuracy at the measurement port of the MFCMU or the MFCMU cable (1.5 m or 3.0 m)
• |Z| accuracy: ± E (%)
• accuracy: ± E/100 (radian)
• C accuracy:
± E (%) at Dx 0.1
± E (1+Dx
2
)
1/2
(%) at Dx > 0.1
• D accuracy:
± E/100 at Dx 0.1
± E (1+Dx)/100 at Dx > 0.1
• G accuracy:
± E/Dx (%) at Dx 0.1
± E (1+Dx
2
)
1/2
/Dx (%) at Dx > 0.1
where,
Zx: Impedance measurement value ( )
Dx: Measurement value of D
E = E
P
’ + (Z
S
’ / |Zx| + Y
O
’ |Zx| ) 100 (%)
E
P
’ = E
PL
+ E
POSC
+ E
P
(%)
Y
O
’ = Y
OL
+ Y
OSC
+ Y
O
(S)
Z
S
’ = Z
SL
+ Z
OSC
+ Z
S
( )
For the parameter value, see Table 4-11 to Table 4-13. Calculation example of
the measurement accuracy is also shown in Table 4-14.
Specification conditions:
• Temperature: 23 C ± 5 C
• Integration time: 1 PLC or 16 PLC
Agilent B1500A User’s Guide, Edition 10 4- 19
Table 4-11
Table 4-12
Table 4-13
Specifications
Hardware
Parameters E
POSC
, Z
OSC
Oscillator level
Vosc mV
125 < Vosc
64 < Vosc
32 < Vosc
Vosc
250
125
64
32
E
POSC
%
0.03
(250/Vosc 1)
0.03
(125/Vosc 1)
0.03
(64/Vosc 1)
0.03
(32/Vosc 1)
Vosc is oscillator level in mV.
Parameters E
PL
, Y
OL
, Z
SL
Cable length
1.5 m
3 m
E
PL
%
0.02+3 f/100
0.02+5 f/100
Y
OL
nS
750 f/100
1500 f/100
Z
OSC
5 (250/Vosc 1)
5 (125/Vosc 1)
5 (64/Vosc 1)
5 (64/Vosc 1)
Z
m
SL
m
5.0
5.0
f is frequency in MHz. If measurement cable is extended, open compensation, short compensation, and load compensation must be performed.
Parameters Y
OSC
, Y
O
, E
P
, Z
S
Y
O
nS E
P
% Z
S
m Frequency f Hz Y
OSC
nS
1k f 200k 1 (125/Vosc 0.5)
200k < f 1M 2 (125/Vosc 0.5)
1M < f 2M
2M < f
2 (125/Vosc 0.5)
20 (125/Vosc 0.5)
1.5
3.0
3.0
30.0
0.095
0.095
0.28
0.28
5.0
5.0
5.0
5.0
Vosc is oscillator level in mV.
4- 20 Agilent B1500A User’s Guide, Edition 10
Specifications
Hardware
Table 4-14 Example of calculated C/G measurement accuracy
Frequency
Measured
Capacitance
C Accuracy a
Measured
Conductance
G Accuracy
5 MHz
1 MHz
100 kHz
10 kHz
1 kHz
1 pF
10 pF
100 pF
1 nF
1 pF
10 pF
100 pF
1 nF
10 pF
100 pF
1 nF
10 nF
100 pF
1 nF
10 nF
100 nF
100 pF
1 nF
10 nF
100 nF
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
0.61 %
0.32 %
0.29 %
0.32 %
0.26 %
0.11 %
0.10 %
0.10 %
0.18 %
0.11 %
0.10 %
0.10 %
0.18 %
0.11 %
0.10 %
0.10 %
± 0.92 %
± 0.18 %
± 0.11 %
± 0.10 %
628 nS
6 S
63 S
628 S
628 nS
6 S
63 S
628 S
3 S
31 S
314 S
3 mS
628 nS
6 S
63 S
628 S
63 nS
628 nS
6
63
S
S
±
± 990 nS
± 9 S
± 99 S
±
±
±
±
±
±
±
±
16 nS
71 nS
624 nS
±
±
±
±
±
±
192 nS
619 nS
±
7
7
S
11 nS
66 nS
S
11 nS
66 nS
619 nS
± 7 S
6 nS
11 nS
66 nS
619 nS a. The calculation examples are specified under the conditions Dx = 0.1, 1 PLC integration time,
30 mVrms test signal level, and at four-terminal pair port of MFCMU.
a
Agilent B1500A User’s Guide, Edition 10 4- 21
Specifications
Hardware
SCUU/GSWU
SCUU: SMU CMU Unify Unit
GSWU: Guard Switch Unit
The SCUU multiplexes the outputs from two SMUs (MPSMUs and/or HRSMUs) and the CMU. The SCUU outputs are two sets of Kelvin triaxial ports (Force and
Sense). The SCUU also allows the SMUs to act as DC bias sources in conjunction with the CMU. Special cables are available to connect the SMUs and CMU with the
SCUU, and an auto-detect feature automatically compensates for the cable length going to the SCUU.
The GSWU contains a relay that automatically opens for IV measurements and closes for CV measurements, forming a guard return path to improve CV measurement accuracy.
• Supported SMU: MPSMU and HRSMU
• SCUU
• Inputs
Triaxial port: Force1, Sense1, Force2, and Sense2
BNC port: for MFCMU
Control port: for MFCMU
• Outputs
Triaxial port: Force1/CMUH, Sense1, Force2/CMUL, and Sense2
Control port: for GSWU
LED: SMU/CMU output status indicator
• Docking mode
Direct and indirect mode
• GSWU
• Input
Control port: for SCUU
Mini pin plug port: Guard1 and Guard2
• Output
LED: Connection status indicator
4- 22 Agilent B1500A User’s Guide, Edition 10
Specifications
Hardware
• SCUU supplemental information
• SMU path
Offset current: < 20 fA
Offset voltage: < 100 V at 300 sec
Closed channel residual resistance: < 200 m
Channel isolation resistance: > 10
15
• CMU path
• Test signal
• Signal output level additional errors (CMU bias, open load):
± 2 % (direct docking)
± 7 % (indirect docking)
• Signal output level additional errors (SMU bias, open load):
± 5 % (direct docking, 10 kHz)
± 10 % (indirect docking, 10 kHz)
• Output impedance: 50 , typical
• Signal level monitor additional errors (open load):
± 2 % (CMU bias), direct docking
± 5 % (SMU bias), direct docking
± 7 % (CMU bias), indirect docking
± 10 % (SMU bias), indirect docking
• DC bias function
• DC voltage bias (CMU bias)
Range: 0 to ± 25 V
Resolution: 1 mV
Additional errors (for CMU bias): ± 100 V (open load)
• DC voltage bias (SMU bias)
Range: 0 to ± 100 V
Resolution: 5 mV
Agilent B1500A User’s Guide, Edition 10 4- 23
Specifications
Hardware
Additional errors (for SMU voltage output accuracy): ± 100 V
(open load)
• DC bias monitor additional errors (open load):
± 20 mV, direct docking
± 30 mV, indirect docking
• Output impedance: 50 , typical
• DC output resistance: 50 (CMU bias), 130 (SMU bias)
• Measurement accuracy
Impedance measurement error is given by adding the following additional error Ee to the MFCMU measurement error.
Ee = ± (A + Zs / |Zx| + Yo |Zx| ) 100 (%)
Zx: Impedance measurement value ( )
A: 0.05 % (direct docking) or 0.1 % (indirect docking)
Zs: 500 (1 + f ) m (f: frequency in MHz)
Yo: 1 + f 10 nS (direct docking, 2 for indirect docking)
When the measurement terminals are extended by using the measurement cable, the measurement accuracy is applied to the data measured after performing the open/short/load correction at the DUT side cable end.
Specification conditions:
• Temperature: 23 C ± 5 C
• Integration time: 1 PLC or 16 PLC
4- 24 Agilent B1500A User’s Guide, Edition 10
Figure 4-1
Specifications
Hardware
HV-SPGU
HV-SPGU: High Voltage Semiconductor Pulse Generator Unit
• Number of output channels: 2 channels per module
• Modes: pulse, constant, and free run
• Standard pulse mode
• Two level pulse
• Three level pulse per one channel
• Pulse period: 30 ns to 10 s
• Delay range: 0 s to 9.99 s
• Delay resolution: minimum 2.5 ns
• Output count: 1 to 1,000,000
• Voltage monitor minimum sampling period: 5 s
• Trigger output
Level: TTL
Timing: Synchronized with pulse period
Trigger width: Pulse period 1/2 (pulse period 10 s), maximum 5 s (pulse period > 10 s)
•
Pulse range and pulse parameter: See Table 4-15.
•
Pulse/DC output voltage and accuracy: See Table 4-16.
SPGU pulse setup parameters
Tperiod
Tdelay
Twidth
Vpeak
Vbase
Vamp
10%
Tr
90% 90%
10%
Tf
Agilent B1500A User’s Guide, Edition 10 4- 25
Specifications
Hardware
Table 4-15 Pulse range and pulse parameter
Item Value a
Frequency range
Pulse period
Pulse width
Programmable range
Resolution
Minimum
Accuracy
Programmable range
Resolution
Minimum
Accuracy
0.1 Hz to 33 MHz
30 ns to 10 s
10 ns
100 ns (Vamp 10 V)
± 1 % (± 0.01 % b )
10 ns to (period 10 ns)
2.5 ns (Tr and Tf 8 s)
10 ns (Tr or Tf > 8 s)
50 ns (25 ns, typical) at Vamp 10 V
± (3 % + 2 ns)
Transition time (leading time Tr and trailing time Tf) c
Programmable range
Resolution
Minimum (typical)
Minimum
8 ns to 400 ms (see below for the minimum transition time)
2 ns (Tr and Tf 8 s)
8 ns (Tr or Tf > 8 s)
< 15 ns (Vamp 10 V)
20 ns (Vamp 10 V)
30 ns (Vamp 20 V)
60 ns (Vamp > 20 V)
Accuracy 5 % to 5 % + 10 ns (Vamp 10 V)
5 % to 5 % + 20 ns (Vamp 20 V)
< 100 s
Output relay switching time d Open/close a. Unless otherwise stated, all specifications assume a 50 termination.
b. Typical minimum. This is the supplemental information.
c. The time from 10 % to 90 % of Vamp which is the amplitude of output pulse.
d. The time it takes the open state relay to open or close.
4- 26 Agilent B1500A User’s Guide, Edition 10
Table 4-16
Specifications
Hardware
Pulse/DC output voltage and accuracy
Item Value Condition
Output voltage (Vout) 20 V to +20 V
40 V to +40 V
± (0.5 % + 50 mV)
50 load open load open load
Accuracy a
Amplitude resolution 0.2 mV (± 10 V range)
0.8 mV (± 40 V range)
0.4 mV (± 10 V range)
1.6 mV (± 40 V range)
50 load open load
Output connectors
Source impedance
SMA
50 b
Short circuit current
Overshoot/pre-shoot/ringing d
800 mA peak (400 mA average c
)
± (5 % + 20 mV) 50 load
Output limit Monitoring over current limit a. At 1 s after completing transition.
b. Typical (± 1 %) c. Specification condition: N 0.2 + Itotal < 3.0 A where, N is the number of installed HV-SPGUs, and Itotal is DC current output by all modules
(including HV-SPGUs) d. Following the specified condition with transition time.
• ALWG (arbitrary linear waveform generator) function
Arbitrary linear waveform generator (ALWG) mode
• Output complex waveform per one channel of HV-SPGU
• Define multi-level pulse and multi-pulse waveform including open state pulse with ALWG GUI editor
• Sequential pulse waveform from user-defined pulse waveform
• 1024 points per one channel
Agilent B1500A User’s Guide, Edition 10 4- 27
Figure 4-2
Figure 4-3
Specifications
Hardware
• Programmable timing range: 10 ns to 671.088630 ms, 10 ns resolution
• SPGU supplemental information
• Pulse width jitter: 0.001 % + 150 ps
• Pulse period jitter: 0.001 % + 150 ps
• Maximum slew rate: 1000 V/ s (50 load)
• Noise: 10 mVrms (at DC output)
• Advanced feature:
Voltage monitor: The HV-SPGU has a voltage monitor function to measure the voltage at the DUT terminal.
Measurement accuracy (open load): ± (0.1 % of reading + 25 mV)
Measurement resolution: 50 V
Note: Specified at 1 PLC (20 ms = (5 s sample + 5 s interval) 2000 samples)
Voltage compensation: The HV-SPGU can measure the impedance of DUT and adjust the output voltage according to the DUT impedance.
ALWG setup table and pattern example
15
10
P3
0
P1
0
P2
P4
Pattern
P5
P7
P6
P8
P9 P10
500 ns
9
10
7
8
3
4
5
6
Point
1
2
Time
0
50 ns
70 ns
100 ns
200 ns
300 ns
320 ns
400 ns
450 ns
500 ns
Voltage
0.0 V
0.0 V
15.0 V
15.0 V
0.0 V
0.0 V
10.0 V
10.0 V
0.0 V
0.0 V
ALWG complex waveform example
Pattern1 x 1 Pattern2 x 5 Pattern3 x 1
4- 28 Agilent B1500A User’s Guide, Edition 10
Specifications
Hardware
Selector
Agilent 16440A (B1500A-A04) SMU/pulse generator selector switches either a
SMU or PGU to the associated output port. You can expand to four channels by adding an additional selector. The PGU port on channel 1 provides a “PGU OPEN” function, which can disconnect the PGU by opening a semiconductor relay. Agilent
B1500A and 16445A are required to use the selector.
The following specifications data is specified at 23 C ± 5 C (73 F ± 9 F) and
50 % relative humidity.
• Channel configuration: 2 channels (CH 1 and CH 2). Can add the additional 2 channels (CH 3 and CH 4) by adding another selector (selector expander).
Input Output
Channel 1 (CH 1)
Channel 2 (CH 2)
Channel 3 (CH 3) b
2 (SMU and PGU a )
2 (SMU and PGU)
2 (SMU and PGU a )
1
1
1
Channel 4 (CH 4) b 2 (SMU and PGU) 1 a. PGU channels 1 and 3 have a built-in series semiconductor relay. b. Available when a selector expander is installed.
• Voltage and current range
Input port Maximum voltage (V) Maximum current (A)
SMU 200 1.0
PGU 40
0.4 a a. This is peak-to-peak ac current. For 50 load. If DUT impedance is lower than 50 , SPGU output voltage should be decreased for preventing the selector from over current.
Selector Adapter
Agilent 16445A selector adapter is required to control and to supply DC power to the selector.
• Power requirement: 100 to 240 V, 50/60 Hz
• Maximum volt-amps (VA): 20 VA
Agilent B1500A User’s Guide, Edition 10 4- 29
Specifications
Hardware
WGFMU/RSU
WGFMU: Waveform Generator/Fast Measurement Unit
RSU: Remote-sense and Switch Unit
The WGFMU is a self-contained module offering the combination of arbitrary linear waveform generation (ALWG) with synchronized fast current or voltage (IV) measurement. The ALWG function allows you to generate not only DC, but also various types of AC waveforms. In addition to this versatile sourcing capability, the
WGFMU can also perform measurement in synchronization with the applied waveform, which enables accurate high-speed IV characterization.
• Number of output channels: 2 channels per module
• Modes: Fast IV, PG (pulse generator), DC, and SMU pass-through
•
Measurement functions: See Table 4-17.
•
Voltage force accuracy, resolution, and timing: See Table 4-18.
•
Voltage measurement accuracy, resolution and noise: See Table 4-19.
•
Current measurement accuracy and resolution: See Table 4-20.
• RF electromagnetic field and WGFMU measurement accuracy
The voltage and current measurement accuracy and the timing accuracy between modules may be affected by RF electromagnetic field of strength over 3 V/m at frequencies 80 MHz to 1 GHz and 1.4 GHz to 2.0 GHz, and 1 V/m at frequencies 2.0 GHz to 2.7 GHz. The extent of this effect depends upon how the instrument is positioned and shielded.
• RSU
• Output terminal
• Connector: SMA
• Source impedance: 50 (nominal), at DC output in PG mode
• SMU path
• Maximum voltage: ± 25 V
• Maximum current: ± 100 mA
• V Monitor terminal
• Connector: BNC
• Source impedance: 50 (nominal), at DC output
4- 30 Agilent B1500A User’s Guide, Edition 10
Specifications
Hardware
The V Monitor terminal outputs a buffered signal equal to 1/10 of the Output terminal voltage (into a 50 load).
• WGFMU to RSU cable length
The WGFMU and RSU are connected by a special composite cable. The following configurations are available.
• 3 m
• 5 m
• 1.5 m
• 2.4 m + connector adapter + 0.6 m
• 4.4 m + connector adapter + 0.6 m
Note: The connector adapter is used when routing the cable through the prober’s connector panel.
•
ALWG function: See Table 4-21.
• Trigger output
Level: TTL
Trigger width: 10 ns
Generated synchronously with ALWG waveform.
• Software
• Instrument library for WGFMU control (supported operating systems:
Microsoft Windows XP Professional SP2 and Vista Business SP1)
• NBTI and general-purpose EasyEXPERT Application Tests
• Sample programs (NBTI and general-purpose measurement using WGFMU and RTS data analysis)
• WGFMU supported prober vendors
Cascade Microtech
Suss MicroTec
Vector Semicon
Note: The maximum number of installable RSUs for a given prober depends upon the available space. Please contact your local sales representative for details on connecting and mounting the WGFMU and RSU.
Agilent B1500A User’s Guide, Edition 10 4- 31
Table 4-17
Specifications
Hardware
Mode
Fast IV
• WGFMU supplemental data
• RSU SMU path
Leakage current: < 100 pA
Residual resistance: < 300 m
• Jitter: < 1 ns
• Skew between channels: < 3 ns, under no electrostatic discharge condition
• Trigger output skew: < 3 ns
• Current range change time: < 150 s
This is the time until the measured current settles within ± 0.3 % of the final result value after the range change.
•
Minimum rise/fall time: See Table 4-22. This is the minimum setting value
effective for suppressing overshoot and distortion.
•
Settling time: See Table 4-23. This is the time until the measured value
settles within ± 0.3 % of the final result value after the output voltage is changed from the initial value (0 V). Applicable condition: Rise time = 10 ns
•
Minimum pulse width: See Table 4-24. This is the time until the pulse peak
output value (0 to 5 V) settles within ± 0.3 % of the setup value after the output voltage is changed from the initial value (0 V). Applicable condition:
Rise time is set to the minimum rise/fall time shown in Table 4-22.
Measurement functions, voltage forcing, voltage measurement, and current measurement
PG
DC
SMU pass through
Function
V force/
I measure,
V force/
V measure
V force/
V measure
V force/
I measure,
V force/
V measure
Measurement using SMU
V force ranges V measure ranges I measure ranges
-
-
-
3 V to +3 V,
5 V to +5 V,
10 V to 0 V,
0 V to +10 V
3 V to +3 V,
5 V to +5 V
3 V to +3 V,
5 V to +5 V,
10 V to 0 V,
0 V to +10 V
Maximum
± 25 V
-
-
-
-
-
5 V to +5 V,
10 V to +10 V
5 V to +5 V
5 V to +5 V,
10 V to +10 V
-
1 A, 10 A,
100 A, 1 mA,
10 mA
1 A, 10
100
A,
A, 1 mA,
10 mA
-
Maximum
± 100 mA
4- 32 Agilent B1500A User’s Guide, Edition 10
Table 4-18
Specifications
Hardware
Voltage force accuracy, resolution, and timing
V force (Fast IV mode)
V force (PG mode)
Accuracy
Resolution
Overshoot/undershoot
Noise
Rise time T
Fall time T
Pulse width b
Pulse period rise fall
(10 to 90 %)/
(90 to 10 %)
5 V to +5 V, 10 V to 0 V, 0 V to +10 V
5 V to +5 V, open load
2.5 V to +2.5 V, 50 load
± 0.1 % of setting ± 0.1 % of range a
96 V ( 3 V to +3 V)
160 V (all ranges except for 3 V to +3 V)
± (5 % + 20 mV) c
Maximum 0.1 mV rms d
Accuracy: 5 % to +(5 % + 10 ns) of setting e
Minimum: 24 ns, PG mode and 50 load
Timing accuracy: ± 1 % of setting f
Minimum: 100 ns, PG mode and 50 load
Accuracy: ± (3 % + 2 ns) g
Minimum: 50 ns, PG mode and 50 load a. Independent of the range or the mode. DC constant voltage output. Load impedance must be 1 M (1 A range) or 200 k (all other current ranges) for Fast IV mode, or 1 M for PG mode.
b. Can vary at most 5 % based on the result of calibration c. PG mode, 50 load, T rise
and T fall
>16 ns with the 1.5 m cable, >32 ns with 3 m cable, or >56 ns with 5 m cable d. Theoretical value for the observed time 100 ns to 1 ms, supplemental information e. PG mode, 50 load, T rise
and T fall
24 ns f. PG mode, 50 load, pulse period 100 ns g. PG mode, 50 load, pulse width 50 ns
Agilent B1500A User’s Guide, Edition 10 4- 33
Table 4-19
Table 4-20
Table 4-21
Specifications
Hardware
Voltage measurement accuracy, resolution, and noise
Accuracy
Resolution b
± (0.1 % of reading + 0.1 % of range) a
680 V, 5 V to +5 V range
1.4 mV, 10 V to +10 V range
Maximum 4 mV rms
( 5 V to +5 V range)
Noise c a. Independent of the range or the mode. DC constant voltage output. Applicable condition: 10,000 averaging samples for 10 A range and above;
100,000 averaging samples for the 1 A range b. Display resolution. Can vary at most 5 % based on the result of calibration c. 0 V output, open load, no averaging. Maximum 1.5 mV rms
as supplemental information
Current measurement accuracy, resolution, and noise
Accuracy
Resolution b
Noise (Effective resolution)
± (0.1 % of reading + 0.2 % of range) a
0.014 % of range
Maximum 0.2 % of range c a. Independent of the range or the mode. DC constant voltage output. Applicable condition: 10,000 averaging samples for 10 A range and above;
100,000 averaging samples for the 1 A range b. Display resolution. Can vary at most 5 % based on the result of calibration c. Effective value at 0 V output, open load, and no averaging. Supplemental information
ALWG and sampling measurement capability
Maximum number of vectors 2048
Maximum number of sequences 512
Maximum number of loop counts
1 to 10 12
Length of a vector
Sampling rate
Averaging time
Hardware memory
10 ns to 10,000 s with 10 ns resolution
5 ns, or 10 ns to 1 s with 10 ns resolution
10 ns to 20 ms with 10 ns resolution
About 4 M data points/channel (typical)
4- 34 Agilent B1500A User’s Guide, Edition 10
Specifications
Hardware
Table 4-22
Mode
PG mode
Fast IV mode
Minimum rise/fall time
Current measurement range
NA
10 mA
1 mA
100 A
10 A
1 A
0 to 1 V
30 ns
80 ns
250 ns
600 ns
2 s
6 s
-
Minimum rise/fall time
0 to 5 V
30 ns
80 ns
250 ns
600 ns
4.5 s
-
35 s
0 to 10 V
NA
80 ns
250 ns
1.5 s
7 s
-
75 s
Table 4-23
Mode
PG mode
Fast IV mode
Settling time, at Rise time = 10 ns
Current measurement range
NA
10 mA
1 mA
100 A
10 A
1 A
Voltage measurement
150 ns
150 ns
150 ns
400 ns
1.2 s
6 s
Settling time
Current measurement
NA
100 ns
250 ns
1 s
10 s
80 s
Load conditions
25 pF, open
25 pF, 1 M
25 pF, open
Load conditions
25 pF, open
25 pF, 1 k
25 pF, 10 k
25 pF, 1 M
25 pF, 100 k
25 pF, 10 M
Table 4-24
Mode
PG mode
Fast IV mode
Minimum pulse width, for pulse peak voltage = 0 to 5 V
Current measurement range
NA
10 mA
1 mA
100 A
10 A
1 A
Minimum pulse width
170 ns
180 ns
500 ns
1.6 s
14.5 s
115 s
Load conditions
25 pF, open
25 pF, 1 k
25 pF, 10 k
25 pF, 100 k
25 pF, 1 M
25 pF, 10 M
Agilent B1500A User’s Guide, Edition 10 4- 35
Specifications
EasyEXPERT Software
EasyEXPERT Software
Operation mode
• Application test mode
• Classic test mode
• Tracer test mode (Curve tracer mode)
• Quick test mode
Key features
• Categorized and predefined application test library
• GUI-based application test editor
• Save/recall My Favorite setups
• Define/customize application library
• Execute measurement (single/repeat/append)
• Quick test execution
• Direct control (GPIB FLEX)
• Save/recall measurement data and settings
• Test result data management
• Import/export device definition, measurement settings, my favorite setup, measurement data, and application library
• Graph plot display/analysis/printing
• Switching matrix control
• Workspace management
• Self-test, self-calibration, diagnostics
Application library
Sample application tests are supplied for the following categories. They are subject to change without notice.
Structure, CMOS, Bipolar (BJT), Memory, Mixed Signal Device, TFT, Discrete,
Reliability, Power Device, Nanotechnology, Utility
4- 36 Agilent B1500A User’s Guide, Edition 10
Specifications
EasyEXPERT Software
Measurement mode details
Agilent B1500A supports the following measurement modes:
• Staircase sweep
• Multi-channel sweep (VAR1’ is not supported)
• Pulsed sweep
• Staircase sweep with pulsed bias
• IV sampling
• High speed IV sampling
• CV sweep
• C-t sampling
• C-f sweep
• List sweep
• Linear search (supported by FLEX command)
• Binary search (supported by FLEX command)
Each SMU can be set to VAR1 (primary sweep), VAR2 (secondary sweep), VAR1’
(synchronous sweep), or CONST (constant voltage/current source).
• VAR1
Primary sweep controls the staircase (DC or pulsed) voltage or current sweep.
Maximum number of VAR1 steps: N
1
= 1001
• VAR2
Subordinate linear staircase or linear pulsed sweep. After primary sweep is completed, the VAR2 unit output value is changed.
Maximum number of VAR2 steps: N
2
= 1001 (condition: 1 N
1
N
2
128128)
• VAR1’
Staircase or pulse sweep synchronized with the VAR1 sweep. Sweep is made with a user specified ratio and offset values.
VAR1’ = a VAR1 + b
“a” is the user specified ratio, and “b” is the user specified offset value.
Agilent B1500A User’s Guide, Edition 10 4- 37
Specifications
EasyEXPERT Software
• CONST
A source unit can be set as a constant voltage or current source depending on the unit.
• Staircase sweep measurement mode
Forces swept voltage or current, and measures DC voltage or current. One channel can sweep current or voltage while up to ten channels can measure current or voltage. A second channel can be synchronized with the primary sweep channel as an additional voltage or current sweep source.
Number of steps: 1 to 1001
Sweep mode: linear or logarithmic (log)
Sweep direction: single or double sweep
Hold time: 0 to 655.35 s, 10 ms resolution
Delay time: 0 to 65.5350 s, 100 s resolution
• Pulsed sweep measurement mode
Forces pulsed swept voltage or current, and measures DC voltage or current. A second channel can be programmed to output a staircase sweep voltage or current synchronized with the pulsed sweep output.
• Staircase sweep with pulsed bias measurement mode
Forces swept voltage or current, and measures DC voltage or current. A second channel can be programmed to output a pulsed bias voltage or current. A third channel can be synchronized with the primary sweep channel as an additional voltage or current sweep source.
• Sampling (time domain) measurement mode
Displays the time sampled voltage/current data (by SMU) versus time.
Sampling channels: up to 10
Sampling mode: linear or logarithmic (log)
Sampling points: 1 to 100,001/(number of channels) for linear sampling, 1 to
1 + (number of data for 11 decades) for log sampling
Sampling interval range: 100 s + 20 s (number of channels 1) to 2 ms in
10 s resolution, or 2 ms to 65.535 s in 1 ms resolution
Hold time, bias hold time: 90 ms to 100 s in 100 s resolution, 0 to 655.35 s in 10 ms resolution
4- 38 Agilent B1500A User’s Guide, Edition 10
Specifications
EasyEXPERT Software
Measurement time resolution: 100 s
• Standby mode
SMUs in “Standby” remain programmed to their specified output value even as other units are reset for the next measurement.
• Current offset cancel
This function subtracts the offset current from the current measurement raw data, and returns the result as the measurement data. This function is used to compensate the error factor (offset current) caused by the measurement path such as the measurement cables, manipulators, or probe card.
• Timestamp
The B1500A supports a time stamp function utilizing an internal quartz clock.
Resolution: 100 s
• Other measurement characteristics
• Measurement control:
Single, repeat, append, and stop
• SMU setting capabilities:
Limited auto ranging, voltage/current compliance, power compliance, automatic sweep abort functions, self-test, and self-calibration
Arithmetic and analysis functions
• User functions
Up to 20 user-defined functions can be defined using arithmetic expressions.
Measured data and pre-defined variables can be used in the computation. The results can be displayed on the LCD.
• Arithmetic operators
+, , *, /, ^, abs (absolute value), at (arc tangent), avg (averaging), cond
(conditional evaluation), delta, diff (differential), exp (exponent), integ
(integration), lgt (logarithm, base 10), log (logarithm, base e), mavg (moving average), max, min, sqrt, trigonometric function, inverse trigonometric function, and so on
• Physical constants
Keyboard constants are stored in memory as follows:
Agilent B1500A User’s Guide, Edition 10 4- 39
Specifications
EasyEXPERT Software
• q: Electron charge, 1.602177E
19 C
• k: Boltzman’s constant, 1.380658E
23 J/K
• (e): Dielectric constant of vacuum, 8.854188E
12 F/m
• Engineering units
The following unit symbols are also available on the keyboard.
a (10
-18
), f (10
-15
), p (10
-12
), n (10
-9
(10
9
), T (10
12
), P (10
15
)
), u or (10
-6
), m (10
-3
), k (10
3
), M (10
6
), G
Analysis capabilities
• Overlay graph comparison
Graphical plots can be stored and overlaid.
• Scale
Auto scale and zoom
• Marker
Marker to min/max, interpolation, direct marker, and marker skip
• Cursor
Direct cursor
• Line
Two lines, normal mode, grad mode, tangent mode, and regression mode
Auto analysis function
On a graphics plot, the markers and lines can be automatically located using the auto analysis setup. Parameters can be automatically determined using automatic analysis, user function, and read out functions.
• Data variable display
Up to 20 user-defined parameters can be displayed on the graphics screen.
• Analysis functions
Up to 20 user-defined analysis functions can be defined using arithmetic expressions.
Measured data, pre-defined variables, and read out functions can be used in the computation. The results can be displayed on the LCD.
4- 40 Agilent B1500A User’s Guide, Edition 10
Specifications
EasyEXPERT Software
• Read out functions
The read out functions are built-in functions for reading various values related to the marker, cursor, or line.
Graph plot
• Display mode
Data display window can be printed. Only X-Y graph can be printed.
• Graph plot file
Graph plot can be stored as image data to clip board or mass storage device.
File type: bmp, gif, png, emf
Output
• Display mode
X-Y graph, list, and parameter
• X-Y graph display
X-axis and up to eight Y-axis. Linear and log scale. Real time graph plotting.
• List display
Measurement data and calculated user function data are listed in conjunction with VAR1 step number or time domain sampling step number. Up to 20 data sets can be displayed.
Other functions
• Import/export files
File type: Agilent EasyEXPERT format, XML-SS format, CSV format
• Data storage
Hard disk drive, DVD-ROM/CD-R/CD-RW drive
• Interfaces
GPIB, interlock, USB (USB 2.0, 2 ea. on front, 2 ea. on rear),
LAN (100BASE-TX/10BASE-T), trigger in/out, digital I/O
Agilent B1500A User’s Guide, Edition 10 4- 41
Specifications
EasyEXPERT Software
• Trigger I/O
Only available using GPIB FLEX commands.
Trigger in/out synchronization pulses before and after setting and measuring DC voltage and current. Arbitrary trigger events can be masked or activated independently.
• External instruments supported by EasyEXPERT Standard edition:
Supported by switching matrix GUI: B2200A, B2201A
Supported by application tests: E5250A (E5252A cards), 4284A/E4980A,
81110A, 3458A
• External instruments supported by EasyEXPERT Plus edition:
All external instruments supported by EasyEXPERT Standard edition
Also supported by switching matrix GUI: E5250A (E5252A cards)
Furnished Software
• Prober control execution files 1
• Desktop EasyEXPERT software with license-to-use for Standard edition 1
• 4155/56 setup file converter tool 1
• VXI plug & play driver 2
4- 42
1. Operating system: Microsoft
later, or Windows
Windows Vista
Business service pack 1 or
XP Professional service pack 2 or later. Language of operating system: English (US)
2. Operating system: Microsoft
Windows
XP Professional, or Windows
2000 Professional. Language of operating system: English (US)
Agilent B1500A User’s Guide, Edition 10
Specifications
Desktop EasyEXPERT Software
Desktop EasyEXPERT Software
Desktop EasyEXPERT is the same software that is built-in to the Agilent B1505A
Semiconductor Device Analyzer, except that it runs on a standalone PC and no support of the tracer test. Just like standard EasyEXPERT, Desktop EasyEXPERT supports all aspects of parametric test, from basic manual measurements to test automation across a wafer in conjunction with a semi-automatic wafer prober.
Features and benefits
• Large application test library
Desktop EasyEXPERT comes with over 200 application tests conveniently organized by device type, application, and technology. Many of these application tests will run on the 4155/4156 without modification, and you can easily edit and customize the furnished application tests to fit your specific needs.
• Offline capability
Desktop EasyEXPERT can be run in either online or offline mode. In the offline mode you can perform tasks such as analyzing data and creating new application tests. This frees up your existing analyzer from being needed for development work and enables you to use it for its primary purpose: making measurements.
• GUI-based classic test mode
Desktop EasyEXPERT offers a classic test mode that maintains the look, feel, and terminology of the 4155/4156 user interface. In addition, it improves the
4155/4156 user interface by taking full advantage of Microsoft
Windows
GUI features.
• Easy test sequencing
A GUI-based Quick Test mode enables you to perform test sequencing without programming. You can select, copy, rearrange and cut-and-paste any application tests with a few simple mouse clicks. Once you have selected and arranged your tests, simply click on the measurement button to begin running an automated test sequence.
• Prober control
All popular semi-automatic wafer probers are supported by Desktop
EasyEXPERT. You can define wafer, die, and module information for probing across an entire wafer. You can also combine wafer prober control with either
Quick Test mode or an application test based test sequence to perform multiple testing on various devices across the wafer.
Agilent B1500A User’s Guide, Edition 10 4- 43
Specifications
Desktop EasyEXPERT Software
• Automatic data export
Desktop EasyEXPERT has the ability to automatically export measurement data in real time, in a variety of formats. You can save data to any drive connected to the PC. If you wish, you can export data to a network drive and view test results on your desktop PC as your instruments are performing the testing in your lab.
System requirements
The following are the minimum requirement for executing Desktop EasyEXPERT.
Operating system and service pack
Language of OS
Processor
Memory
Display
HDD
LAN interface
.NET Framework
IO libraries
Microsoft
Windows
XP
Professional SP2 or later
Microsoft
Windows Vista
Business SP1 or later
English (US) English (US)
Intel
Celeron
2 GHz
Vista certified PC with 1 GB memory
512 Megabytes DDR266
XGA 1024 768 (SXGA 1280 1024 recommended)
1 GB free space on the C drive, 10 GB (30 GB recommended) free space on a drive for test setup/result data storage.
Only for Plus edition, Ethernet IEEE 802.3 10/100BASE-T
Microsoft
.NET
Framework Ver 2.0
Redistributable Package
Microsoft
.NET
Framework 2.0 SP1
Microsoft
.NET Framework
Ver 3.0
Only for online execution, Agilent IO Libraries Suite 15.0
• Supported GPIB I/F, only for online execution:
Agilent 82350B
Agilent 82357A
Agilent 82357B
B1500A
Supported
Not supported
Not supported
4155B/C, 4156B/C
Supported
Supported
Supported
4- 44 Agilent B1500A User’s Guide, Edition 10
Specifications
Desktop EasyEXPERT Software
• Supported instruments:
B1500A, 4155B, 4156B, 4155C, and 4156C
Supported 4155/4156 firmware: HOSTC: 03.08 or later and SMUC: 04.08 or later
• External instruments supported by Desktop EasyEXPERT Standard edition:
Supported by switching matrix GUI: B2200A, B2201A
Supported by application tests: E5250A (E5252A cards), 4284A/E4980A,
81110A, 3458A
• External instruments supported by Desktop EasyEXPERT Plus edition:
All external instruments supported by Desktop EasyEXPERT Standard edition
Also supported by switching matrix GUI: E5250A (E5252A cards)
Supported 4155/4156 functionality
• Desktop EasyEXPERT Standard edition:
I/V Sweep, B2200A/B2201A switching matrix GUI control
• Desktop EasyEXPERT Plus edition:
The following functions are additionally supported.
I/V-t Sampling except thinned out mode, VSVMU except differential voltage measurement using VMU, PGU (41501B), E5250A/E5252A switching matrix
GUI control
• Setup converter tool
In addition to Desktop EasyEXPERT, Agilent supplies a free setup converter tool that runs on any Windows
based PC. This tool can convert 4155 and 4156 setup files (file extension MES or DAT) into equivalent Desktop EasyEXPERT classic test mode setup files.
Agilent B1500A User’s Guide, Edition 10 4- 45
Specifications
General Specifications
General Specifications
• Temperature range
Operating
Storage
• Humidity
+5 C to +40 C
20 C to +60 C
Operating
Storage
• Altitude
Operating
20 % to 70 %RH, non-condensing
10 % to 90 %RH, non-condensing
0 to 2,000 m (6,561 ft.)
Storage 0 to 4,600 m (15,092 ft.)
• Power requirement: 90 to 264 V, 47 to 63 Hz
• Maximum volt-amps (VA): 900 VA
• Regulatory compliance
EMC IEC61326-1 / EN61326-1
AS/NZS CISPR 11
Safety CSA C22.2 No.1010.1-1992
IEC61010-1 / EN61010-1
UL Std No. 61010B-1
• Certification: CE, CSA(c/us), C-Tick
• Dimensions
B1500A: 420 mm (W) 330 mm (H) 575 mm (D)
N1301A-100 SCUU: 148 mm (W) 75 mm (H) 70 mm (D)
N1301A-200 GSWU: 33.2 mm (W) 41.5 mm (H) 32.8 mm (D)
E5288A ASU: 132 mm (W) 88.5 mm (H) 50 mm (D)
B1531A RSU: 45.2 mm (W) 70 mm (H) 82 mm (D)
16440A Selector: 250 mm (W) 50 mm (H) 275 mm (D)
16445A Selector adapter: 250 mm (W) 50 mm (H) 260 mm (D)
• Weight
B1500A (empty) 20 kg, B1510A 2.0 kg, B1511A 1.0 kg, B1517A 1.2 kg,
E1520A 1.5 kg, E1525A 1.3 kg, E1530A 1.3 kg, E1531A 0.13 kg, E5288A 0.5 kg, N1301A-100 0.8 kg, N1301A-200 0.1 kg, 16440A 1.1 kg, 16445A 1.0 kg
4- 46 Agilent B1500A User’s Guide, Edition 10
5 Accessories and Options
Table 5-1
Accessories and Options
Furnished accessories, available accessories, and available options of Agilent
B1500A Semiconductor Device Analyzer are described in this chapter.
Furnished Accessories
Description Quantity
USB keyboard
USB mouse
Stylus pen
Interlock cable, 1.5 m or 3.0 m
GNDU cable, 1.5 m or 3.0 m
GNDU Kelvin adapter a
Triaxial cable a
, 1.5 m or 3.0 m
Power cable
Desktop EasyEXPERT CD
License-to-use for Desktop EasyEXPERT Standard edition
Software CD (including VXI plug & play driver and utility tools)
WGFMU instrument library and sample program CD
Disk set for Agilent 4155B/4155C/4156B/4156C firmware update
1
SMU number label, only for the B1500A installed with SMU
PG number label, only for the B1500A installed with SPGU
1
1 a. GNDU Kelvin adapter must be directly connected to the B1500A
GNDU connector for taking out the GNDU Force and Sense to the individual connectors. Then the GNDU cable must be used for extending the GNDU Force. And the triaxial cable must be used for the Sense.
1
1
1
1
1
1
1
1
1
1
1
1
Cable length 1.5 m or 3.0 m is specified by the option B1500A-015 or B1500A-030.
5- 2 Agilent B1500A User’s Guide, Edition 10
Accessories and Options
Table 5-2 Options
Option Item Description
B1500A-015
B1500A-030
B1500A-050
B1500A-060
B1500A-A00
B1500A-A01
B1500A-A02
B1500A-A03
B1500A-A04
B1500A-A10
B1500A-A11
B1500A-A17
B1500A-A20
B1500A-A25
B1500A-A28
B1500A-A30
1.5 m length of bundled cables
3.0 m length of bundled cables
50 Hz power line frequency
60 Hz power line frequency
Empty package for custom solution, contains no measurement module
Standard package, contains four MPSMU and eight triaxial cables
High resolution package, contains four HRSMU and eight triaxial cables
High power package, contains two HPSMU, two MPSMU, and eight triaxial cables
Flash memory cell measurement basic package, see Table 5-3
HPSMU add-on package, adds one HPSMU and two triaxial cables
MPSMU add-on package, adds one MPSMU and two triaxial cables
HRSMU add-on package, adds one HRSMU and two triaxial cables
Capacitance measurement add-on package, adds the MFCMU and one CMU cable
HVSPGU add-on package, adds one HVSPGU and two SPGU cables
ASU add-on package, adds one ASU, one D-sub cable, and one triaxial cable
WGFMU add-on package, adds one WGFMU, two RSU, and two RSU cables
B1500A-A31
B1500A-A3P
B1500A-A5F
B1500A-A6J
WGFMU add-on package with connector adapters, see Table 5-4
WGFMU probe cable kit, see Table 5-5
Test fixture for package device measurement, adds one 16442B, see Table 5-6
ANSI Z540 compliant calibration
B1500A-ABA Paper manual set, English
B1500A-ABJ Paper manual set, Japanese
B1500A-UK6 Commercial calibration certificate with test data
Agilent B1500A User’s Guide, Edition 10 5- 3
Table 5-3
Table 5-4
Accessories and Options
B1500A-A04 Basic Flash Memory Cell Package
Description
Medium power source/monitor unit (MPSMU)
High resolution source/monitor unit (HRSMU)
High voltage semiconductor pulse generator unit (HVSPGU)
SPGU cable, 1.5 m or 3.0 m
16440A SMU/PGU pulse generator selector
16445A selector adapter for 16440A
Control cable, 1.5 m, between B1500A and 16445A
Control cable, 40 cm, between 16445A and 16440A
Triaxial cable, 1.5 m, between B1500A and 16440A
Triaxial cable, 1.5 m or 3.0 m
B1500A-A31
1
WGFMU Add-on Package with Connector Adapter
Description
Waveform generator/fast measurement unit (WGFMU)
Remote-sense and switch unit (RSU)
RSU cable, 2.4 m, between WGFMU and connector adapter
RSU cable, 0.6 m, between RSU and connector adapter
16493R-801 connector adapter (female-female)
Quantity
2
2
1
2
2
Quantity
1
1
1
1
2
8
1
2
2
2
1. The option B1500A-A31 cannot be selected with the option B1500A-015.
5- 4 Agilent B1500A User’s Guide, Edition 10
Table 5-5
Table 5-6
Accessories and Options
B1500A-A3P WGFMU Probe Cable Kit
Description
16493R-101 SSMC short-open cable for current return path,
50 mm
16493R-102 SSMC short-open cable for current return path,
75 mm
16493R-202 SMA-SSMC cable between RSU and DC probe,
200 mm
16493R-302 SMA-SMA cable between RSU and RF probe,
200 mm
B1500A-A5F
1
Test Fixture for Package Device Measurement
Description
16442B test fixture
Accessory case
Blank Teflon board for DUT stage
28-pin DIP (dual-in-line) package socket module
Universal socket module, 0.075 inch pitch
Universal socket module, 0.05 inch pitch
Connection pin set for universal socket module
Connection wire, mini banana to pin plug
Connection wire, pin plug to pin plug
Connection wire, mini banana to mini clip
Connection wire, mini banana to mini banana
Quantity
1
1
10
4/color
1
1
1
1
3/color
3/color
3/color
Quantity
2
2
2
2
1. Contains four types of the connection wire. There is three colors for each connection wire, black, red, and blue.
Agilent B1500A User’s Guide, Edition 10 5- 5
Accessories and Options
Table 5-7
Model
Number
16440A
Available Accessories
Option Item
16442B
16444A
Description
SMU/PGU pulse generator selector
16440A-001 Control cable, 1.5 m
16440A-002 Control cable, 3.0 m
16440A-003 Control cable, 40 cm for second selector
Test fixture
16442B-010 Add triaxial cables, 1.5 m, 4 ea.
16442B-011 Add triaxial cables, 3 m, 4 ea.
16442B-800 Extra blank Teflon board
16442B-801 Universal socket module, 0.1 inch pitch, with 10 pins
16442B-802 Universal socket module, 0.075 inch pitch, with 10 pins
16442B-803 Universal socket module, 0.05 inch pitch, with 10 pins
16442B-810 Extra pin set (for universal socket module, 10 pins.)
16442B-811 Extra wire set (mini banana to pin plug, 6 ea.)
16442B-812 Extra wire set (pin plug to pin plug, 6 ea.)
16442B-813 Extra wire set (mini banana to mini clip, 6 ea.)
16442B-814 Extra wire set (mini banana to mini banana, 6 ea.)
16442B-821 Socket module, 4-pin TO package
16442B-822 Socket module, 18-pin DIP package
16442B-823 Extra socket module, 28-pin DIP package
16442B-890 Extra accessory case
Accessories for B1500A
16444A-001 USB keyboard
16444A-002 USB mouse
16444A-003 Stylus pen
5- 6 Agilent B1500A User’s Guide, Edition 10
Model
Number
16445A
16493G
16493J
16493K
16493L
16493M
16493N
16493P
Option Item Description
Selector adapter for 16440A
16445A-001 Control cable (B1500 to 16445A), 1.5 m
16445A-002 Control cable (B1500 to 16445A), 3.0 m
Digital I/O connection cable
16493G-001 1.5 m length
16493G-002 3 m length
Interlock cable
16493J-001 1.5 m length
16493J-002 3 m length
16493J-003 5 m length
Kelvin triaxial cable (B1500 to B1500)
16493K-001 1.5 m length
16493K-002 3 m length
GNDU cable
16493L-001 1.5 m length
16493L-002 3 m length
16493L-003 5 m length
Triaxial and D-sub cables for ASU
16493M-001 1.5 m length
16493M-002 3 m length
GNDU cable for B2200 Kelvin input
16493N-001 2 m length
SPGU output connection cable (SMA to BNC)
16493P-001 1.5 m length
16493P-002 3 m length
Agilent B1500A User’s Guide, Edition 10
Accessories and Options
5- 7
Accessories and Options
Model
Number
16493Q
Option Item
16493R
16494A
16494B
Description
SPGU SPGU connection cable (SMA to SMA)
16493Q-001 8 cm length
WGFMU Cables and Accessories
16493R-001 WGFMU-to-RSU cable, 0.6 m
16493R-002 WGFMU-to-RSU cable, 2.4 m
16493R-003 WGFMU-to-RSU cable, 3 m
16493R-004 WGFMU-to-RSU cable, 5 m
16493R-005 WGFMU-to-RSU cable, 4.4 m
16493R-006 WGFMU-to-RSU cable, 1.5 m
16493R-101 SSMC short-open cable for current return path, 50 mm
16493R-102 SSMC short-open cable for current return path, 75 mm
16493R-202 SMA-SSMC cable between RSU and DC probe, 200 mm
16493R-302 SMA-SMA cable between RSU and RF probe, 200 mm
16493R-801 WGFMU connector adapter (female-female)
16493R-802 Magnet stand for RSU
16493R-803 Sync terminal connection cable
Triaxial cable
16494A-001 1.5 m length
16494A-002 3 m length
16494A-003 80 cm length
16494A-004 40 cm length
16494A-005 4 m length
Kelvin triaxial cable (B1500 to E5250)
16494B-001 1.5 m length
16494B-002 3 m length
16494B-003 80 cm length
5- 8 Agilent B1500A User’s Guide, Edition 10
Accessories and Options
Model
Number
16495F
16495G
16495H
16495J
16495K
B1510A
B1511A
B1517A
B1520A
B1525A
B1530A
B1531A
B1540A
Option Item Description
Connector plate w/ 12 triax., Interlock, GNDU
16495F-001 Bulkhead feedthrough connectors (female to female)
16495F-002 Connectors to contacts for soldering
Connector plate w/ 24 triax., Interlock, GNDU
16495G-001 Bulkhead feedthrough connectors (female to female)
16495G-002 Connectors to contacts for soldering
Connector plate w/ 6 triax., 6 coax., Interlock, GNDU
16495H-001 Bulkhead feedthrough connectors (female to female)
16495H-002 Connectors to contacts for soldering
Connector plate w/ 8 triax., 4 coax., Interlock, GNDU
16495J-001 Bulkhead feedthrough connectors (female to female)
16495J-002 Connectors to contacts for soldering
Connector plate with universal cable holder
16495K-001 Connector plate with rubber holder
High Power Source/Monitor Unit module (HPSMU)
Medium Power Source/Monitor Unit module (MPSMU)
High Resolution Source/Monitor Unit module (HRSMU)
Multi Frequency Capacitance Measurement Unit module (MFCMU)
Semiconductor Pulse Generator Unit module (SPGU)
Waveform Generator/Fast Measurement Unit (WGFMU)
B1530A-0KN Self-paced sample program learning kit
Remote-sense and Switch Unit (RSU)
EasyEXPERT software
B1540A-001 Standard edition
B1540A-002 Plus edition (supports E5250A+E5252A by switching matrix GUI)
Agilent B1500A User’s Guide, Edition 10 5- 9
Accessories and Options
Model
Number
B1541A
E5288A
N1253A
N1254A
N1300A
N1301A
Option Item Description
Desktop EasyEXPERT software
B1541A-001 Standard edition
B1541A-002 Plus edition (supports E5250A+E5252A by switching matrix GUI and expands 4155/4156 support functions)
Atto Sense and Switch Unit (ASU)
E5288A-001 Add triaxial and D-sub cables, 1.5 m
E5288A-002 Add triaxial and D-sub cables, 3 m
Accessories for Digital I/O
N1253A-100 Digital I/O T-cable
N1253A-200 Digital I/O BNC Box
Accessories
N1254A-100 GNDU Kelvin Adapter
N1254A-108 ASU Magnetic Stand
CMU cable
N1300A-001 1.5 m length
N1300A-002 3 m length
Accessories for CMU
N1301A-100 SMU CMU Unify Unit (SCUU)
N1301A-102 SCUU cable, 3 m
N1301A-110 SCUU magnetic stand
N1301A-200 Guard Switch Unit (GSWU)
N1301A-201 GSWU cable, 1.5 m
N1301A-202 GSWU cable, 3 m
5- 10 Agilent B1500A User’s Guide, Edition 10
advertisement
Related manuals
advertisement
Table of contents
- 28 To Turn On/Off B1500A
- 28 To Turn B1500A On
- 28 To Turn B1500A Off
- 28 To Launch EasyEXPERT
- 28 If Only One Workspace Exists
- 28 To Create Workspace
- 28 To Select Workspace
- 28 To Use Tracer Test Mode
- 28 To Use Application Test Mode
- 28 To Use Classic Test Mode
- 28 To Perform Measurement
- 28 To Use Test Result Editor
- 28 To Use Analysis Tools
- 29 Overview
- 29 Agilent EasyEXPERT Software
- 29 Front View
- 29 Rear View
- 29 Measurement Units