110/240
VAC
2AMP
PS902
12VDC
2x18
SCHLAGE
MT15
READER
PULL SIDE
6x18
CT5000
EPT
2/10
* 2x12
4x18
THIS IS NOT A FIRE RATED APPLICATION
FREE EGRESS ALWAYS PERMITTED
TITLE:
BRENDA DOVE
DRAWN/CHECKED BY:
DWG NO:
NOTE:
USE #12 GAUGE WIRE FOR DISTANCES UP TO 200' FROM EPT TO PS914.
USE #14 GAUGE WIRE FOR DISTANCES UP TO 100' FROM EPT TO PS914.
110/240
VAC
2AMP
OPERATION:
SCHLAGE MT15 READER TO RETRACT THE
ELECTRIC LATCH ON PANIC BAR TO ALLOW ENTRY.
EL PANIC
DEVICE
PS914-2RS
24VDC
THIS DIAGRAM REPRESENTS A GENERIC CONFIGURATION. CUSTOM WIRING