Instruction Manual

ROS-HT-W-25

High-Temperature Remote Optical Sensor

15 Columbia Drive

Amherst, NH 03031 USA

Phone: (603) 883-3390 • Fax: (603) 886-3300

E-mail: [email protected]

Website: www.monarchinstrument.com

SAFEGUARDS AND PRECAUTIONS

Read and follow all instructions in this manual carefully, and retain this manual for future reference.

Do not use this instrument in any manner inconsistent with these operating instructions or under any conditions that exceed the environmental specifications stated.

This instrument is not user serviceable. For technical assistance, contact the sales organization from which you purchased the product.

In order to comply with EU Directive 2012/19/EU on Waste Electrical and Electronic Equipment (WEEE): This product may contain material which could be hazardous to human health and the environment. DO NOT

DISPOSE of this product as unsorted municipal waste. This product needs to be

RECYCLED in accordance with local regulations; contact your local authorities for more information. This product may be returnable to your distributor for recycling; contact the distributor for details.

Monarch Instrument’s Limited Warranty applies.

See www.monarchinstrument.com for details.

Warranty Registration and Extended Warranty Coverage information is available online at www.monarchinstrument.com

.

TABLE OF CONTENTS:

1.0 DESCRIPTION ..................................................................... 1

2.0 CONNECTION DETAIL .......................................................... 1

3.0 OPERATING INSTRUCTIONS ................................................ 1

4.0 SPECIFICATIONS .................................................................

3

4.1 Dimensions of Mounting Bracket (inches) .....................

4

4.2 Compliance ...................................................................

4

5.0 ACCESSORIES .....................................................................

4

1.0 DESCRIPTION

The High-Temperature Remote Optical Sensor has a visible incandescent white light source and can accurately measure speeds from 1-50,000 RPM from a distance of up to 24 inches with a maximum offset angle of 30 degrees from the rotating object.

It is ideal for measuring rotational speed in high temperature environments up to 257 °F [125 °C]. The sensor is housed in a threaded 303 stainless steel tube and supplied with a 90 degree mounting bracket, jam nuts and a 25 ft. shielded cable terminated with tinned wires.

2.0 CONNECTION DETAIL

Wire Color Function

Red

Black

White

Shield

Positive Power Supply

Common

Signal (0 to + V dc pulse)

Housing Ground

Unit

(+V)

(Com)

(Sig)

(Gnd)

3.0 OPERATING INSTRUCTIONS

The ROS-HT-W-25 High-

Temperature Remote Optical

Sensor is capable of detecting a reflected pulse from a target consisting of reflective tape at distances of up to 24 inches

[0.76 m] from the rotating object and angles up to 30 degrees. For most applications, a ½ " [12 mm] square piece of T-5 Reflective Tape should be applied to a clean area on the rotating object.

1

Note: The T-5 tape supplied with the ROS-HT-W-25 is rated at

175 °F [79.4 °C] for continuous exposure and 250 °F [121 °C] for intermittent exposure (30 minutes).

The sensor should be mounted and optically aligned to illuminate the target once per revolution. The user must hold “steady” or mount the ROS-HT-W-25 to obtain an accurate measurement. It is recommended that the optical Sensor be placed at a slight angle

(15 degrees) from perpendicular, so that the Sensor will receive only pulses from the reflective marker. The ROS-HT-W-25 should be at least 1 inch from the reflective target to avoid false triggering.

The ROS-HT-W-25 will work with all Monarch panel instruments that accept pulse inputs (e.g. ACT Series, F2A Frequency to Analog

Converter/Tachometers, DataChart™ 1250, DataChart™ 6000).

CAUTION: DO NOT HANDLE SENSOR AT ELEVATED

TEMPERATURES.

2

4.0 SPECIFICATIONS

Specifications*

Speed Range

Operating

Temperature

Operating Range

ROS-HT-W-25

1-50,000 RPM

-13 °F to 257 °F [-25 °C to 125 °C]

Up to 24 " [0.76 m] and 30° offset from target

Power Required

Illumination

Output Signal

Standard Cable

Connection

Material

Lens

Dimensions

6-24 V dc @ 48 mA

Incandescent lamp

Positive pulse 0 to input voltage (+V)

25 ft. [7.6 m]

Tinned wires

303 stainless steel supplied with two M16 jam nuts and mounting bracket

Glass Pyrex

Threaded tube 2.90 in. x 1.5 in. x 0.62 in. diameter [M16 x 74 mm] long

*Specifications are subject to change without notice.

M16 x 1.5

2.90" [74.0 mm] 0.62" [15.9 mm]

3

4.1 Dimensions of Mounting Bracket (inches)

4.2 Compliance

• CE Compliant

• Low Voltage Directive (LVD) 2014/35/EU

• Electromagnetic Compatibility Directive (EMC) 2014/30/EU

• Restriction of Hazardous Substances (RoHS 3) Directive

2015/863/EU

5.0 ACCESSORIES

See Accessories webpage for details.

Reflective Tape

T-5 (single pack), 5 feet - PN: 6180-070

T-5 (2-pack), 5 feet each - PN: 6180-069

T-50, 50 feet - PN: 6180-072

T-5WP (waterproof), 5 feet - PN: 6180-079

ROS Mounting Bracket

PN: 1052-4350-112

ROS M16 Jam Nut

PN: 1053-0189-001

4

The Professional’s Choice

Monarch Instrument is committed to excellence and quality in manufacturing, sales, and service.

Portable

Tachometers

Track-It ™ Data Loggers Panel Tachometers

Fixed Mounted

Strobes

Portable Strobes Frequency

Converters

Speed Sensors DataChart ™ Paperless

Recorders

15 Columbia Drive, Amherst NH 03031 USA

Tel.: (603) 883-3390 // Fax: (603) 886-3300

Email:

[email protected]

Website:

www.monarchinstrument.com

© Copyright 2006-2022 Monarch Instrument All rights reserved.

1071-4854-315 1122

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement