VESDA VLP Product manual

Add to my manuals
46 Pages

advertisement

VESDA VLP Product manual | Manualzz

Xtralis VESDA VLP

Product Guide

August 2008

Document Number: 10278_07

Part Number: 19145

Xtralis

VESDA

® Xtralis VESDA VLP Product Guide

Intellectual Property and Copyright

This document includes registered and unregistered trademarks. All trademarks displayed are the trademarks of their respective owners.

Your use of this document does not constitute or create a licence or any other right to use the name and/or trademark and/or label.

This document is subject to copyright owned by Xtralis AG (“Xtralis”). You agree not to copy, communicate to the public, adapt, distribute, transfer, sell, modify or publish any contents of this document without the express prior written consent of Xtralis.

Disclaimer

The contents of this document is provided on an “as is” basis. No representation or warranty (either express or implied) is made as to the completeness, accuracy or reliability of the contents of this document. The manufacturer reserves the right to change designs or specifications without obligation and without further notice. Except as otherwise provided, all warranties, express or implied, including without limitation any implied warranties of merchantability and fitness for a particular purpose are expressly excluded.

General Warning

This product must only be installed, configured and used strictly in accordance with the General Terms and Conditions, User Manual and product documents available from Xtralis. All proper health and safety precautions must be taken during the installation, commissioning and maintenance of the product. The system should not be connected to a power source until all the components have been installed.

Proper safety precautions must be taken during tests and maintenance of the products when these are still connected to the power source.

Failure to do so or tampering with the electronics inside the products can result in an electric shock causing injury or death and may cause equipment damage. Xtralis is not responsible and cannot be held accountable for any liability that may arise due to improper use of the equipment and/or failure to take proper precautions. Only persons trained through an Xtralis accredited training course can install, test and maintain the system.

Liability

You agree to install, configure and use the products strictly in accordance with the User Manual and product documents available from

Xtralis.

Xtralis is not liable to you or any other person for incidental, indirect, or consequential loss, expense or damages of any kind including without limitation, loss of business, loss of profits or loss of data arising out of your use of the products. Without limiting this general disclaimer the following specific warnings and disclaimers also apply:

Fitness for Purpose

You agree that you have been provided with a reasonable opportunity to appraise the products and have made your own independent assessment of the fitness or suitability of the products for your purpose. You acknowledge that you have not relied on any oral or written information, representation or advice given by or on behalf of Xtralis or its representatives.

Total Liability

To the fullest extent permitted by law that any limitation or exclusion cannot apply, the total liability of Xtralis in relation to the products is limited to:

(i) in the case of services, the cost of having the services supplied again; or

(ii) in the case of goods, the lowest cost of replacing the goods, acquiring equivalent goods or having the goods repaired.

Indemnification

You agree to fully indemnify and hold Xtralis harmless for any claim, cost, demand or damage (including legal costs on a full indemnity basis) incurred or which may be incurred arising from your use of the products.

Miscellaneous

If any provision outlined above is found to be invalid or unenforceable by a court of law, such invalidity or unenforceability will not affect the remainder which will continue in full force and effect. All rights not expressly granted are reserved.

www.xtralis.com

i

Xtralis VESDA VLP Product Guide

Document Conventions

The following typographic conventions are used in this document.

Xtralis

Convention Description

Bold

Used to denote: emphasis

Used for names of menus, menu options, toolbar buttons

Italics

Used to denote: references to other parts of this document or other documents. Used for the result of an action.

The following icons are used in this document

Convention Description

Caution: This icon is used to indicate that there is a danger to equipment. The danger could be loss of data, physical damage, or permanent corruption of configuration details.

Warning: This icon is used to indicate that there is a danger of electric shock. This may lead to death or permanent injury.

VESDA

®

Warning: This icon is used to indicate that there is a danger of inhaling dangerous substances. This may lead to death or permanent injury.

Contact Us

The Americas

Asia

Australia and New Zealand

Continental Europe

+1 781 740 2223

+8 52 2297 2438

+61 3 9936 7000

+41 55 285 99 99

UK and the Middle East

+44 1442 242 330

www.xtralis.com

ii www.xtralis.com

Xtralis

VESDA

® Xtralis VESDA VLP Product Guide

Codes and Standards Information for Air Sampling Smoke Detection

We strongly recommend that this document is read in conjunction with the appropriate local codes and standards for smoke detection and electrical connections. This document contains generic product information and some sections may not comply with all local codes and standards. In these cases, the local codes and standards must take precedence. The information below was correct at time of printing but may now be out of date, check with your local codes, standards and listings for the current restrictions.

FCC Compliance Statement

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, the user is encouraged to try to correct the interference by one or more of the following measures; re-orientate or relocate the receiving antenna, increase the separation between the equipment and receiver, connect the equipment to a power outlet which is on a different power circuit to the receiver or consult the dealer or an experienced radio/television technician for help.

FDA

This VESDA product incorporates a laser device and is classified as a Class 1 laser product that complies with FDA regulations 21 CFR

1040.10. The laser is housed in a sealed detector chamber and contains no serviceable parts. The laser emits invisible light and can be hazardous if viewed with the naked eye. Under no circumstances should the detector chamber be opened.

FM Hazardous Applications

3611 Hazardous Approval Warning: Exposure to some chemicals may degrade the sealing of relays used on the detector. Relays used on the detector are marked “TX2-5V”, “G6S-2-5V” or “EC2-5NU”.

VESDA detectors must not be connected or disconnected to a PC while the equipment is powered in an FM Division 2 hazardous

(classified) location (defined by FM 3611).

FM Approved Applications

The product must be powered from VPS-100US-120, VPS-100US-220 or VPS-220 only.

ONORM F3014

ONORM F3014, transport times for all tubes (including capillaries) must not exceed 60 seconds from any hole. This means that the predesigned pipe networks that include capillaries cannot be used.

AS1603.8

The performance of this product is dependent upon the configuration of the pipe network. Any extensions or modifications to the pipe network may cause the product to stop working correctly. You must check that ASPIRE2 approves alterations before making any changes.

ASPIRE2 is available from your VESDA ASD distributor.

AS1851.1 2005

Maintenance Standards. Wherever this document and the AS1851.1 differ, AS1851.1 should be followed in preference to this document.

European Installations

The product must use a power supply conforming to EN54: Part 4.

Regional Regulatory Requirements and Notices

UL

For open area protection the fire alarm threshold (signal) that initiates an evacuation procedure via the Fire Alarm Panel must not be set less sensitive than 0.625%/ft. The detector can send this signal via the Fire Alarm Panel Output signal or the Pre-alarm output signal.

EN54-20

The product must use a power supply conforming to EN 54-4.

The product is compliant with EN 54-20 sensitivity requirements provided the following conditions are met:

• For a Class A detector, hole sensitivity must be better than 1.5% obscuration/m and transport time less than 60 seconds

• For a Class B detector, hole sensitivity must be better than 4.5% obscuration/m and transport time less than 90 seconds

• For a Class C detector, hole sensitivity must be better than 10% obscuration/m and transport time less than 120 seconds

These limits should be verified using ASPIRE2 during the design of the sampling pipe network.

The product is compliant with EN 54-20 flow monitoring requirements provided the following conditions are met:

• The minor low and minor high flow thresholds should be set at 85% and 115% respectively

• The flow through the detector predicted by ASPIRE2 should be in the range 20 to 115 lpm

Additional information:

• Class A detectors passed EN 54-20 approvals testing with 30 holes and 0.05% obscuration/m detector sensitivity

• Class B detectors passed EN 54-20 approvals testing with 60 holes and 0.06% obscuration/m detector sensitivity

• Class C detectors passed EN 54-20 approvals testing with 100 holes and 0.08% obscuration/m detector sensitivity

www.xtralis.com

iii

Xtralis VESDA VLP Product Guide Xtralis

VESDA

®

Approvals

• UL

• ULC

• FM

• LPCB

• VdS

• CFE

• ActivFire

• AFNOR

• VNIIPO

• CE - EMC and CPD

• EN 54-20

Regional approvals listings and regulatory compliance vary between Xtralis VESDA product models. Refer to www.xtralis.com for the latest product approvals matrix.

Document: 10278_06

Part: 19145

iv www.xtralis.com

Xtralis

VESDA

®

Contents

Xtralis VESDA VLP Product Guide

1. Scope ............................................................................................................................................3

2. Introduction to the VLP ...............................................................................................................3

VLP Features ..........................................................................................................................3

3. Operation of the VLP ...................................................................................................................3

VLP Configurations .................................................................................................................5

Display module ...................................................................................................................6

Xtralis VESDA LCD Programmer ........................................................................................8

VLP Components ....................................................................................................................9

4. VLP Product Information ..........................................................................................................10

Product Specifications ...........................................................................................................10

VLP Dimensions ....................................................................................................................12

Default Settings .....................................................................................................................14

Relays ...................................................................................................................................15

VLP relay Assignments and Conditions to Change States ...............................................15

Relays default settings ......................................................................................................16

General Purpose Input (GPI) Functions ............................................................................17

5. Mounting the VLP ......................................................................................................................19

Securing the mounting bracket .............................................................................................19

Mounting the VLP in Normal Orientation ..........................................................................19

Mounting the VLP in the Inverted Orientation ...................................................................20

Mounting the VLP without a mounting bracket .................................................................20

Recess mounting kit ..........................................................................................................21

6. Connecting the VLP to the Pipe Network ................................................................................22

Inlet Pipes .............................................................................................................................22

Managing the Exhaust Air .....................................................................................................23

7. VLP Wiring Connections ..........................................................................................................24

The Termination Card ...........................................................................................................24

VESDAnet Terminals ........................................................................................................24

Connections for GPI ..........................................................................................................25

Typical Wiring To Fire Alarm Control Panel (FACP) .........................................................26

Wiring To an Address Loop Module. .................................................................................26

8. Power Source ............................................................................................................................27

9. Back Up Battery .........................................................................................................................28

10. Powering Up ............................................................................................................................29

Installation Checklist .............................................................................................................30

11. Preliminary Systems Check ...................................................................................................31

12. Maintaining the VLP detector .................................................................................................31

Replacing the chassis/Air Inlet Pipe Manifold .......................................................................32

Internal Wiring for VLP ..........................................................................................................34

Spare Parts ...........................................................................................................................36

www.xtralis.com

1

Xtralis VESDA VLP Product Guide Xtralis

VESDA

®

2 www.xtralis.com

Xtralis

VESDA

®

1 Scope

Xtralis VESDA VLP Product Guide

The Xtralis VESDA VLP Product Guide is written to provide you with comprehensive knowledge of the detector.

This guide introduces you to the VLP features, technical specifications and gives an understanding of its components and their function. You will also find instructions on installing, cabling and powering up the detector.

This guide is for anyone involved with the design, maintenance and purchasing of an Xtralis

VESDA system. It is assumed that anyone using this manual has knowledge and the appropriate certification from the local fire and electrical authorities.

2 Introduction to the VLP

The VLP is an aspirating smoke detector providing very early warning of fire conditions by drawing air samples through an air sampling pipe network. The detector chamber can detect presence of smoke at very low concentrations. The embedded and PC software complimenting the VLP provides a wide range of user defined parameters and reporting capabilities. The detector easily interfaces with fire warning and fire suppression release systems, and can be easily integrated into a building management system.

VLP Features

The VLP features make it a versatile smoke detection product:

Each detector can cover an area up to 2,000 m

2

(20,000 sq. ft.)

Wide sensitivity range

Four programmable alarm thresholds

AutoLearn feature

Four pipe Inlets

Individual pipe flow monitoring

Replaceable air filter cartridge

Option for inverted mounting

Recessed mounting option

Modular to meet site specific requirements

Modular Display Module and LCD Programmer

Seven programmable relays

High efficiency aspirator

Programmable general purpose Input

PC capable programming and monitoring

Multilingual displays

Event log for up to 18,000 events

3 Operation of the VLP

An air sampling pipe network collects air samples from a protected area. The Xtralis VESDA integrated aspirator draws air into the sampling pipes through a pipe inlet manifold (up to four pipes can be connected to a VLP detector). For further information on air sampling pipe networks please see the Pipe Network Design and Installation Manuals.

Some of this air flows to the dual stage filter. The first stage air filter removes dust and dirt from the sampled air and flows to the laser detector chamber to detect the presence of smoke.

www.xtralis.com

3

Xtralis VESDA VLP Product Guide Xtralis

VESDA

®

Any smoke detected in the laser detection chamber is signaled to the main processor card. If the presence of detected smoke is higher than the set thresholds it is reported as an alert, action, fire

1 or fire 2 alarm depending upon the alarm thresholds. The second stage filter further filters the air to produce ultra clean air. The ultra clean air is used to clean the optical surfaces in the laser detection chamber.

A

E

D

C

F

Legend

A Air inlets from pipe networks

B Air is drawn into the aspirator

C Some air is filtered and:

D flows into the chamber for testing

E is filtered a second time, then used to flush the chamber with ultra clean air

F All air is then vented

Figure 1 - Operation and internal air flow of a VLP

B

4 www.xtralis.com

Xtralis

VESDA

®

VLP Configurations

The modular options available with a VLP are:

Fire and OK LEDs (FOK)

LCD Programmer

VLP Display Module

Xtralis VESDA VLP Product Guide

Figure 2 - VLP-012 installed with LCD Programmer and Display Module

www.xtralis.com

5

Xtralis VESDA VLP Product Guide

Display module

Xtralis

VESDA

®

The VLP Display Module is mounted either on the detector front cover or at a remote location in a remote mounting box or a 19” subrack. It provides a visual representation of the smoke levels and the four alarm stages for the assigned detector. An array of fault LEDs illuminate in different configurations to report Urgent, Minor, Zone and System faults. Up to 20 Display Modules can be assigned to one detector, however the Display Module can be configured to report the status of only one detector at a time.

B

C

A

D

F

E

Legend

A Alarm Threshold Indicators

B Bar graph of detected smoke

C Numerical Display

D Alarm LEDs

E Fault LEDs

F Push Button Keys

Figure 3 - Display Module for VLP

6 www.xtralis.com

Xtralis

VESDA

®

OK LED

Isolate LED

Alarm Levels

Bar graph

Threshold

Indicators

Fault LEDs

Xtralis VESDA VLP Product Guide

The OK LED stays illuminated during normal operation indicating the unit is functioning normally. When this LED is off a warning beep sounds, indicating a

Fault condition is active.

This LED is illuminated when the detector is Isolated and relays are deactivated disabling alarm outputs of the detector. The display can be programmed to beep every 60 seconds.

ALERT: When illuminated this LED indicates that the smoke level is above the alert threshold. This means the detector has identified very early stages of a fire condition and/or that the smoke level in the area is above normal.

ACTION: When illuminated this LED indicates that the detected smoke level has passed the threshold value fixed for Action, but is not intended to initiate a general fire alarm response procedure.

FIRE 1: When illuminated this LED indicates that the detected smoke level is above the threshold value set to initiate a general fire alarm response procedure.

This indicates a fire may be imminent or is in progress. When interfaced with a Fire Alarm Control

Panel (FACP) it can generate an automatic fire alarm.

FIRE 2: When illuminated this LED indicates a fire is in progress. The detector can be interfaced with an FACP to activate automatic suppression systems and evacuation procedures.

The Bar graph is a 20 step indicator where each indicator represents an increase in the detected level of smoke, relative to the preset fire alarm level.

The illuminated LEDs represent visual settings for ALERT, ACTION, and FIRE

1 alarm levels. The FIRE 1 indicator is always at the top.

The Fault LEDs illuminate to indicate:

URGENT: A serious fault requiring immediate attention

SYSTEM: A fault affecting the network to which the Display Module is connected

ZONE: A fault in the VESDA Zone monitored by the Display Module

POWER: A fault in the power supply if the GPI function is used

NETWORK: A communications fault on VESDAnet

AIRFLOW: Higher or lower than acceptable levels of air flow through the inlet pipe(s)

FILTER: The air filter requires changing

Figure 4 - IllumInated lights showing faults

www.xtralis.com

7

Xtralis VESDA VLP Product Guide Xtralis

VESDA

®

Push Button

Keys

Numerical

Display

These buttons enable various systems functions. These do not allow configuring the system. The buttons can be disabled by the systems administrator.

Mode/Test (Dual Function): Selects modes on the numerical display - sensitivity, smoke level, or zone number. When depressed for more than two seconds it performs a light test function.

Silence: This button silences any alarm or fault warnings. The LEDs stop flashing to acknowledge a fault or alarm condition.

Reset: Resets any latched alarms and faults on the detector. Any active alarms or faults are reported again after the time delays have elapsed.

Isolate: Isolates the detector from any external devices or systems (an isolate alarm will normally be raised at the Fire Alarm Control Panel).

Note: It is normal practise to signal the Isolate condition to the Fire Control

Panel using the Isolate relay.

Sensitivity: Shows the level of smoke that must be measured to illuminate the entire bar graph and always corresponds with the Fire 1 alarm level.

Smoke Level: Indicates the current level of smoke in the relevant VESDA

Zone and is represented as % obs/m or % obs/ft.

Zone Number: This is the VESDA Zone number assigned to the Display

Module.

Note: The Mode button is used to select the parameter to display in the numeric display. These values represent the current readings for the corresponding parameters mentioned alongside the lit LED.

Xtralis VESDA LCD Programmer

The Xtralis VESDA LCD Programmer is used for configuring, commissioning and maintenance of the devices on VESDAnet. It can replace either the center or the right plate of the front cover of the detector, or can be mounted at a remote location. A hand-held model is also available. The hand-held model is connected to the VESDAnet socket on the termination card of the detector.

For a detailed description and use of the LCD Programmer please refer to the Xtralis VESDA

LCD Programmer Product Guide.

8

Legend

A Display

B Keys

Figure 5 - LCD Programmer module

www.xtralis.com

Xtralis

VESDA

®

VLP Components

B

C

A

D

Xtralis VESDA VLP Product Guide

E

F

G

Legend

A Front cover

B Termination card

C Blank card protecting processor card

D Chassis with laser detector chamber

E Pipe inlet manifold

F Air filter

G Aspirator

H Mounting box/enclosure

Figure 6 - An exploded view of the detector

H

www.xtralis.com

9

Xtralis VESDA VLP Product Guide

4 VLP Product Information

Xtralis

VESDA

®

Product Specifications

Supply Voltage

Power Consumption

• VLP with Blank Plates

3,000rpm

• VLP with Blank Plates @

4,200rpm

• Programmer Module

• Display Module

Dimensions (WHD)

Weight

Operating Temperature

(To operate the VLP detector outside these parameters please contact your nearest

VESDA Technical Office)

Storage Temperatures

(Non-operational)

Sampling Pipe Network

Pipe Size

Relays

Relays Default Configuration

IP Rating

Cable Access

Cable Termination

Alarm Range

18 to 30 VDC

@24 VDC

Normal: 5.8 W

Alarm On: 7.0 W

Normal: 9.6 W

Alarm On: 10.8 W

Normal: 0.6 W (Backlight Off)

Alarm On: 2.2 W (Backlight On)

Normal: 1.6 W

Alarm On: 2.2 W

350 mm x 225 mm x 125 mm (13.8 in x 8.9 in x 4.9 in)

4.0 kg (9 lbs) including Display and Programmer Modules

Detector Ambient:

UL tested: 0° to 39°C (32° F to 103°F)

Sampled Air: -20° to 60°C (-4° to 140°F)

Humidity: 10-95% RH, non-condensing

Up to 2 years (battery life)

Dry (<95% humidity)

0° to 85°C

Must not exposed to sunlight or other radiation sources

Maximum length per pipe 100 m (328 ft)

Aggregate pipe length: 200 m (650 ft)

Pipe Modelling Design Tool: ASPIRE2™

Internal Diameter: 15-21 mm (0.874 inch)

External Diameter: 25 mm (1.05 inch)

(25 mm to 1.050 inch adaptor supplied for USA market)

7 relays. Contacts rated 2A @ 30 VDC.

Programmable to latch or non-latch states

Programmable 0 - 60 seconds time delay for each relay

7 relays:

Alert, Action, Fire 1, Fire 2, Minor Fault, Urgent Fault and Isolate.

(7 x NO/NC contacts)

IP30

8 x 25 mm (1in) knockouts in various positions

Screw terminal blocks (0.2-2.5 sq mm, 30-12 AWG)

0.005 to 20.00% obs/m

(0.0015 to 6.25% obs/ft.)

10 www.xtralis.com

Xtralis

VESDA

® Xtralis VESDA VLP Product Guide

Threshold Setting Range Alert: 0.005 - 1.990% obs/m

(0.0015 - 0.6218% obs/ft.)

Action: 0.010 - 1.995% obs/m

(0.0031 - 0.6234% obs/ft.)

Fire 1: 0.015 - 2% obs/m

(0.0046 - 0.625% obs/ft.)

Fire 2: 0.020 - 20% obs/m

(0.0062 - 6.25% obs/ft.)**

** Limited to 12% obs/m 4% obs/ft. in UL mode

All shipments are factory configured for UL Mode. If the UL Mode is switched OFF the UL listing will be voided.

Key Software Features

Event log:

AutoLearn:

Up to 18,000 events stored on FIFO basis

Minimum 15 minutes

Maximum 15 days, 23 hrs, 59 minutes

Recommended minimum period 14 days

• Referencing:

• Four Alarm Levels:

During AutoLearn, thresholds are NOT changed from pre-set values

Compensation for external ambient conditions

Alert, Action, Fire 1 and Fire 2

• Two Fault Warning Levels: Minor Fault and Urgent fault

• Maintenance Aids: Filter and flow monitoring

Note:

Note:

Note:

Event reporting via VESDAnet or event log

Table 1 - VLP Detectors Specifications

For operating the VLP Detector outside the parameters mentioned above please contact Xtralis VESDA Technical Support

UL Mode: Factory Default = ON (Fire 2 set to 12% obs/m 4% obs/ft. to comply with

UL268)

Factory Default = OFF (Fire 2 Threshold can be set up to 20% obs/m 6.25%/ft).

www.xtralis.com

11

Xtralis VESDA VLP Product Guide

VLP Dimensions

Xtralis

VESDA

®

Figure 7 - VLP dimensions - rear view

12 www.xtralis.com

Xtralis

VESDA

® Xtralis VESDA VLP Product Guide

Figure 8 - VLP dimensions

www.xtralis.com

13

Xtralis VESDA VLP Product Guide

Default Settings

Parameter

Event Log - Events

• Smoke Level

• Alarms

• Faults

• User Action

Fire 2 Threshold

Fire 1 Threshold

Action Threshold

Alert Threshold

Alarm Delays…Fire 2

Alarm Delays…Fire 1

Alarm Delays…Action

Alarm Delays…Alert

Delay Times

Instant Fire

Change-over Times:

• Day

• Night

Weekend

Holidays:

• First Day

• Last Day

Smoke Change:

• Change By

• Min. Interval

AutoLearn

Default Value

Enabled

Enabled

Enabled

Enabled

2% obs/m 0.625% obs/ft.

0.2% obs/m

0.0625% obs/ft.

0.14% obs/m

0.044% obs/ft.

0.08% obs/m

0.025% obs/ft.

10 seconds

10 seconds

10 seconds

10 seconds

Simultaneous

Disabled

Range

Minimum

N/A

N/A

N/A

N/A

0.02% obs/m

0.0062% obs/ft.

0.015% obs/m

0.0046% obs/ft.

0.010% obs/m

0.0031 obs/ft.

0.005% obs/m

0.0015% obs/ft.

0 seconds

0 seconds

0 seconds

0 seconds

Simultaneous

Enabled

07:00:00

19:00:00

Two seconds

Saturday & Sunday Adjust to suit environment

1-Jan-90

1-Jan-90

0.02% obs/m

0.0062% obs/ft.

2 seconds

14 days

0 Hours

0 Minutes

Adjust to suit environment

0.005% obs/m

0.0015% obs/ft.

2 seconds

0 Days

0 Hours

15 minutes

Air flow Thresholds:

• High Urgent

• High Minor

• Low Minor

• Low Urgent

• Delay

Flow Control:

• Aspirator Speed

Filter Service Interval

130%

120%

80%

70%

0 seconds

3,000rpm

731 days (2 years)

105%

105%

25%

25%

0 seconds

3,000rpm

1 Day

Xtralis

VESDA

®

Maximum

Access

Level

N/A

N/A

N/A

N/A

20.% obs/m

6.25% obs/ft.

2% obs/m

0.6250% obs/ft.

1.995% obs/m

(0.6234% obs/ft.

1.990% obs/m

0.6218% obs/ft.

60 seconds

60 seconds

60 seconds

60 seconds

Cumulative

Disabled

Adm

Adm

Adm

Adm

Adm

Adm

Adm

Adm

Adm

Adm

Adm

Adm

Adm

Adm

11:59:58

Adjust to suit environment

Adjust to suit environment

Adm

Adm

Adm

0.2% obs/m

0.0625% obs/ft.

10 seconds

15 days

23 Hours

59 Minutes

Adm

Dst

Adm

Adm

Adm

200%

200%

95%

95%

60 seconds

Adm

Adm

Adm

Adm

Adm

4,200rpm

3655 days (10 years)

Adm

Adm

14 www.xtralis.com

Xtralis

VESDA

® Xtralis VESDA VLP Product Guide

Parameter Default Value

Range

Minimum Maximum

Access

Level

Reference detector:

• Reference Zone No.

• Dilution

• Delay

Display - relay Card

Relay Set

255

100%

2 minutes

None

(display only - 7 relay fitted)

See Table 3, “Relay

assignments and conditions to change state for 7 relays

HTC,” on page 16

Selectable

1%

0 minutes

Selectable depending on card fitted

See Table 3,

“Relay assignments and conditions to change state for 7

relays HTC,” on page 16

Selectable

100%

15 minutes

Selectable depending on card fitted

Adm

Adm

Adm

Adm

See Table 3,

“Relay assignments and conditions to change state for

7 relays HTC,”

on page 16

Adm

Communications:

Network Delay

Preferred Port

Health Check

Open - ended

UL Version

15 seconds

A

10 seconds

N/A

45 seconds

N/A

45 seconds

None

On

40 seconds

N/A

Selectable

60 seconds

N/A

Selectable

Table 2 - Factory default settings and permissible thresholds

DST

DST

DST

DST

Adm

Relays

The relays on the head termination card interface to Fire Alarm Control Panels to communicate faults, alarms and isolate states. The relays can be programmed using PC based software or the

LCD Programmer and can be assigned multiple assignments. See the LCD Programmer {rpdict

Giode for details. relays 3 and 6 are permanently set for Urgent Fault and Fire 1 respectively and can be programmed for additional functions. The table below illustrates default assignments for relays and assignment of multiple functions. It is possible to assign the same function to more than one relay.

VLP relay Assignments and Conditions to Change States

Relays 1, 2, 4, 5 and 7 are fully configured. (For example, relay 5 could be configured to deenergize on Alert)

www.xtralis.com

15

4

5

2

3

6

7

Xtralis VESDA VLP Product Guide

Note:

These relays may be assigned additional assignments.

Xtralis

VESDA

Assignments to relays 3 and 6 are fixed to Urgent Fault and Fire 1 respectively.

®

Relay #

1

Default

Isolate

State change

Energizes when an operator isolates the detector by pressing the Isolate key on the Display Module or by activating the command via a PC or a LCD Programmer or GPI option.

Minor Fault De-energizes when a Minor Fault is detected.

Urgent Fault De-energizes when an Urgent Fault is detected.

Alert

Action

Energizes when the Alert alarm is initiated.

Energizes when the Action alarm is initiated.

Fire 1

Fire 2

Energizes when the Fire 1 alarm is initiated.

Energizes when the Fire 2 alarm is initiated.

Table 3 - Relay assignments and conditions to change state for 7 relays HTC

Latch

Unlatched

Latched

Latched

Latched

Latched

Latched

Latched

Relays default settings

Relay

Isolate

Minor Fault

Urgent Fault

Alert

Action

Fire1

Fire 2

Note:

1

a

2

a

3

a

4

a

5

a

6

a

7

a

A a

indicates the default setting. Relays 3 and 6 are permanently configured for

Urgent Fault and Fire 1 respectively. All other relays can be re configured. More than one function can be configured to any relay.

Table 4 - Default relay assignment

16 www.xtralis.com

Xtralis

VESDA

®

General Purpose Input (GPI) Functions

Xtralis VESDA VLP Product Guide

The input terminal requires a voltage supply between 5V and 30 VDC to operate. The input is isolated from the system by an opto-coupler device. Connect the GPI + terminal to the positive output and the GPI - terminal to the ground output of the external device. The GPI can be configured to initiate a number of different actions - including, by default, a Remote Reset function. The GPI can be configured through the ‘Miscellaneous’ screen menu of the LCD programmer. See the LCD Programmer Product Guide for details.

Function

External

Reset

State change

Detector Reset when

≥ 5 VDC is at this terminal.

Mains OK

Standby

Mode

Isolate

Use

Night-time

Threshold

Reset+

Isolate

Inverted

Reset

Note:

Note:

Reset

The detector monitors the state of the external power supply and responds to the following conditions.

Mains OK

≥ 5 VDC at this terminal

Mains Fail

≤ 2 VDC at this terminal

The detector Isolates and the aspirator turns OFF when

≥ 5 VDC is at this terminal

Note: No Alarms can be generated in this state

The detector isolates when the voltage rises above 5 VDC and Deisolates when the voltage falls below 5V.

The detector switches over from day-time to night-time thresholds when

≥ 5 VDC are at these terminals.

Mains Fault Reported

Day Night Day

While power is applied to the GPI the detector is isolated. In addition, the disconnection or connection of power to the GPI resets the unit.

≥ 5 VDC detector isolates

≤ 2 VDC detector reset

This is the reverse of the normal reset function.

≤ 2 VDC detector reset

≥ 5 VDC normal operating mode

Reset Isolated Reset

Reset

Table 5 - GPI functions

The signal voltage into the GPI terminals must be between 5 to 30 VDC.

When the detector is isolated or de-isolated as a GPI function, the status cannot be changed through the normal isolate/de-isolate functions of the Display Module or the LCD Programmer.

www.xtralis.com

17

Xtralis VESDA VLP Product Guide Xtralis

VESDA

®

Note:

When the night-time threshold is configured as a GPI function, it overrides the clock settings for day-start and night-start.

When using the standby or remote isolate options it is recommended that all displays on

VESDAnet are configured to have the Isolate button disabled. When programming the display through the LCD Programmer choose Isolate Disabled from the Button Lockout menu.

18 www.xtralis.com

Xtralis

VESDA

®

5 Mounting the VLP

Xtralis VESDA VLP Product Guide

The VLP detector can be mounted onto the wall or on any suitable secure surface using the mounting bracket. It is strongly recommended that the detector is mounted on to the mounting bracket included with the packaging. Determine the cable entry ports and the air exhaust port before mounting the detector. Consideration should also be given to the positioning of the pipe inlet ports in relation to the existing pipe network.

Caution:

Press out the relevant knockouts taking care not to damage the relays and terminals on the termination card.

Securing the mounting bracket

The orientation required for the VLP detector will determine how the mounting bracket is placed.

To secure the mounting bracket to the mounting surface place the flat side against the surface ensuring that the lances do not sit flush to the surface. The figure below illustrates the bracket position for normal and inverted orientations. Secure the mounting bracket to the surface using appropriate fasteners, ensuring that the bracket is horizontally straight and sits flush on the surface.

Figure 9 - The mounting bracket in normal and inverted orientation

Mounting the VLP in Normal Orientation

Place the three bridges located at the rear of the detector onto the lances of the mounting bracket. Push downwards until it locks onto the lances and engages the fitting dimples. To prevent unwanted removal of the detector, secure the detector to the mounting surface by placing two screws through the keyhole slots situated near the termination card.

www.xtralis.com

Figure 10 - Mounting the VLP detector onto the mounting bracket

19

Xtralis VESDA VLP Product Guide

Mounting the VLP in the Inverted Orientation

Xtralis

VESDA

®

If the detector is fitted with a LCD Programmer and/or a Display Module, re-orient these to the upright position. Mount the detector in inverted orientation onto the mounting bracket.

Figure 11 - Mounting the VLP detector in inverted orientation onto the mounting bracket

Mounting the VLP without a mounting bracket

In the event the detector has to be mounted directly onto the mounting surface, remove the

chassis from the mounting box. See Replacing the chassis/Air Inlet Pipe Manifold on page 32 for

details.

Use the four keyhole slots to secure the mounting box to a flat surface, ensuring that it is horizontally straight. Re-install the chassis into the mounting box. Carefully re-connect the looms

and complete the cabling prior to closing the front cover. See Internal Wiring for VLP on page 34

Note:

The laser detector chamber, head processor card and flow sensors are factory calibrated as a matched set. Separating the set and replacing it with components from another set may cause the detector to malfunction, requiring re-calibration at the factory.

20 www.xtralis.com

Xtralis

VESDA

®

Recess mounting kit

These kits are used to house a detector inside a wall cavity.

Xtralis VESDA VLP Product Guide

Figure 12 - Recess mounting kit

www.xtralis.com

21

Xtralis VESDA VLP Product Guide

6 Connecting the VLP to the Pipe Network

Xtralis

VESDA

®

Inlet Pipes

The inlets in the pipe inlet manifold are designed to receive a standard pipe of 25 mm (1 in) OD.

A 25 mm to 1.050 inches adaptor to fit the pipe inlet manifold is included for all shipments to

USA.

Figure 13 - Pipe Adaptor

The design of the air inlet ports allow insertion of the sampling pipe to a depth of 15 mm. (0.60 in). This prevents the sampling pipes from damaging the flow sensors. While connecting the detector to the pipe network:

Ensure a minimum length of 500 mm (19.7 in) of straight pipe before terminating the pipes at the air inlet ports of the detector.

Square off and de-burr the end of the sampling air pipes, ensuring the pipes are free from swarf.

Determine the Air Inlet Ports to be used. See Table 6 on page 22 for details.

Remove the plugs from only those Air Inlet Ports intended for use.

• Insert the pipes into the pipe inlet(s) ensuring a firm fit.

Note:

DO NOT glue the inlet pipes to the pipe inlet manifold.

When configuring the detector ensure that the correct pipes in use are selected.:

No. of Pipes

3

4

1

2

Preferred Pipe Inlet Port to Use

Pipe 1 Pipe 2 Pipe 3

a a a a a a a a

Table 6 - Preferable use of pipe inlet ports

Pipe 4

a a

Figure 14 - Pipe inlet port numbering

22 www.xtralis.com

Xtralis

VESDA

®

Managing the Exhaust Air

Xtralis VESDA VLP Product Guide

To exhaust air from the detector, use the exhaust ports at the rear or at the bottom of the head mounting box. Remove the appropriate exhaust port plugs and if required, connect an outlet pipe to the exhaust manifold. In the event the side port is used as an exhaust port, press out the knockout hole. Remove the plug on the exhaust manifold, located at the divider of the chassis and the termination card. Run a 25 mm (1 inch) pipe through the side port and insert into the exhaust manifold, ensuring it is a tight fit.

Note:

Some applications may require the air exhausted from the detector to be returned to the sampling area.

www.xtralis.com

23

Xtralis VESDA VLP Product Guide

7 VLP Wiring Connections

Xtralis

VESDA

®

A

B

The Termination Card

The termination card acts as the interface for VESDAnet, power supply, relays and the General

Purpose Input (GPI).

C

B

C

D

E

F

Legend

A VESDAnet Terminals

Power Terminals

Relay Terminals

GPI Terminal

VESDAnet Socket

FOK LED Connectors

D

E

F

Figure 15 - Terminal card illustrating relays and termination points

VESDAnet Terminals

VESDAnet is a bidirectional data communication network between connected Xtralis VESDA devices. VESDAnet cables are terminated at the VESDAnet A and B Terminals on the termination card. Communication wires from another Xtralis VESDA device are brought into the detector at one terminal and looped out to another device on VESDAnet from the other terminal.

It is necessary to maintain the polarity throughout the network. It is recommended that RS 485

(Belden 9841 - 120 Ohm) twisted pair cables, or similar cables be used.

24 www.xtralis.com

Xtralis

VESDA

® Xtralis VESDA VLP Product Guide

The VLP detector is shipped with the VESDAnet A and B terminals looped. If the detector is not to be networked with other devices, then do not disturb this loop. Remove this loop to connect the detector to the VESDAnet.

Figure 16 - Stand-alone VESDAnet connection

Figure 17 - An example of the wire connection for VESDAnet (closed loop for illustrative purposes only)

Connections for GPI

GPI - 0V

11

+ 24 VDC

GPI+

10

Figure 18 - Wire connection details (GPI)

www.xtralis.com

25

Xtralis VESDA VLP Product Guide Xtralis

VESDA

®

Typical Wiring To Fire Alarm Control Panel (FACP)

The diagram below shows the correct way to wire Xtralis VESDA laser detectors to a conventional fire alarm control panel (FACP). It also shows where an End Of Line (EOL) resistor is correctly installed.

To next detector or EOL resistor

Fire Panel (FACP) Detector

Normally Closed (NC)

FIRE 1 Common (C)

Normally Open (NO)

Normally Closed (NC)

ACTION Common (C)

Normally Open (NO)

Normally Closed (NC)

FAULT Common (C)

Normally Open (NO)

GPI

(Set to reset)

EOL

Input

Short = Fire

Open = Fault

(NC)

Reset (C)

(NO)

Figure 19 - Typical wiring to a fire panel with EOL

Wiring To an Address Loop Module.

This wiring example is for wiring Xtralis VESDA detectors to a typical Address Loop module 3 input 1 output. These are example drawings. Refer to the appropriate product manual for the exact wiring details of the third party equipment .

Detector

Normally Closed (NC)

FIRE 1 Common (C)

Normally Open (NO)

Normally Closed (NC)

ACTION Common (C)

Normally Open (NO)

Normally Closed (NC)

FAULT Common (C)

Normally Open (NO)

EOL

EOL

EOL

3 output 1 input Loop Module

Fire Input

Short = Fire

Open = Wiring Fault

Pre Alarm

Short = Fire

Open = Wiring Fault

Fault Input

Short= Detector Fault

Open = Wiring Fault

EOL

GPI

(Set to reset)

(NC)

Reset (C)

(NO)

To FACP

To Next Detector

Figure 20 - Addressable Loop Module with EOL

26 www.xtralis.com

Xtralis

VESDA

®

8 Power Source

Xtralis VESDA VLP Product Guide

There are two sets of power terminals on the termination card. Use one set to connect to a 24

VDC power supply and if required loop out to another device via the second set. The detector has reverse polarity protection to minimize the risk of reverse power connection to the detector.

For further information see Product Specifications on page 10.

Caution:

The VLP detector will not operate when the supply is reversed.

Note:

Operating the detector when DC supply voltage is outside the voltage range of 18

VDC and 30 VDC may cause damage to the device.

Figure 21 - Wire connection details for power terminals on relays termination card

www.xtralis.com

27

Xtralis VESDA VLP Product Guide

9 Back Up Battery

Xtralis

VESDA

®

The power supply for the VLP detector is switched to a back up battery in the event of a mains power supply disruption. The size of the back up battery is determined by local standards and codes, the total power required by the system, back up time required, allowance for reduction in capacity with age and expected temperature variations.

Note:

It is recommended that batteries be inspected and changed as per manufacturer’s specifications or as per your local codes and standards.

To facilitate the calculation of the backup battery size a Battery Calculation Sheet is included below.

Equipment

Detector @ 3000rpm

Detector @ 3500rpm

Detector @ 4000rpm

Detector @ 4200rpm

Integral Display

Integral Programmer

Remote Display

Remote Programmer

Hand-held

Programmer

Systems relay

Module

Remote termination card - 7 relays

Other 24V loads

320

340

60

20

Normal loads @ 24 V DC

Load mA Qty.

Total

240

280

(backlight off)

90

50

(backlight off)

50

(backlight off)

60

60

Full alarm load @ 24 V DC

Load mA

290

330

370

390

80

80

(backlight on)

110

110

(backlight on)

110

(backlight on)

105

105

Qty.

Total

Total mA

Total mA

X X

Standby Hours Alarm Hours

=

Standby Capacity Alarm Capacity

Total Capacity =

Standby + Alarm

Divided by 1000 for

Standby Capacity

Multiply by battery factor X1.25

Table 7 - Calculating the size of backup battery

28 www.xtralis.com

Xtralis

VESDA

®

Note:

Xtralis VESDA VLP Product Guide

If intelligent VESDA power supply is fitted it will report power failures (F15) on

VESDAnet. VLP & VLS with GPI terminals connected will maintain their aspirator speed for an hour after the loss of mains power. After which, the aspirator speed will be limited to 3000 rpm to conserve power.

10 Powering Up

A VLP detector must be powered up by Xtralis VESDA accredited personnel only.

After installing the VLP detector it is necessary to power up the system.

The system takes approximately 15 seconds to power up.

If the system fails to power up, check all power wires are secured to its terminals and the polarities of the power wires are correctly terminated.

On power up:

The aspirator starts up and air is felt flowing out of the exhaust port

If a programmer module is fitted, the word “VESDA” will be displayed

If a Display Module is fitted, the following indicators are lit:

Fire Alarm Threshold indicators

Smoke Threshold indicators on bargraph

Two digit numerical display

Various fault indicators if there are any faults

System OK indicator if there are no faults

If any of the above does not happen, contact your commissioning engineer or distributor to troubleshoot.

Note:

It is normal for the detector to display troubles immediately after power up. Reset the detector by pressing the reset button on the front cover of the detector to unlatch the relays and fault LEDs. The LEDs for any remaining faults cover will illuminate.

Proceed with the preliminary systems check.

www.xtralis.com

29

Xtralis VESDA VLP Product Guide

Installation Checklist

Xtralis

VESDA

®

Site Name

Address

Detector Serial Number(s) and Date of Manufacture

Interface Card Serial

Number & Date of

Manufacture

Name of Installer

Signature

Date

Perform the following checks listed below to ensure that all the necessary items are completed before handing over to a commissioning engineer.

No INSTALLATION CHECKS

1. Were the detector and the mounting bracket intact in the box?

2. Is the detector securely locked onto its mounting bracket? Note that the two mounting bracket securing-screws are provided in a separate bag with the detector.

3. Is the sampling air pipe firmly connected to the air inlet port?

Ensure the pipe is NOT glued.

4. Have the power wires been connected to the correct terminals on the detector?

5. If required, has the end of line resistor been connected?

6. Have the alarm signalling wires been terminated to the correct terminals of the detector?

7. Has the Interface card been correctly installed according to the instructions provided (if applicable)?

8. Has the plug at the exhaust port been removed and the exhaust pipe (if fitted) not glued?

9. Has the front cover been replaced correctly?

10.Has AutoLearn Flow and AutoLearn Smoke been performed?

Please state the AutoLearn Smoke period____________

11.Is the air sampling pipework installed and checked as per the site plans?

Yes

Table 8 - Installation Checklist

30 www.xtralis.com

Xtralis

VESDA

®

11 Preliminary Systems Check

Xtralis VESDA VLP Product Guide

A preliminary systems check is required after installing the VLP detector, before it is commissioned for use. The check can be conducted by connecting the detector to a LCD

Programmer or using VSC or VSM4 PC based software. The preliminary systems check includes:

Conducting a VESDAnet communications check

Selecting pipes in use

Accepting factory default configurations, or changing to site requirements

Normalizing the air flow

Conducting a basic pass/fail smoke test

For details on preliminary systems check refer to the LCD Programmer or the relevant software manuals

Refer to the VESDA LCD Programmer and Commissioning Guides for further details.

12 Maintaining the VLP detector

To maintain the VLP at its peak performance the maintenance schedule given below should be followed. Maintenance can be conducted by the original installer, a VESDA distributor, or a service contractor. To work effectively the VLP detector needs to be supported by a well designed pipe network. The VESDA Maintenance Manual contains a schedule for pipe network maintenance.

Maintenance Check Quarterly

Six

Monthly

Annual

Every Two

Years

Power Supply

Check Pipe Network a a

Filter Inspection

Pipe Integrity Smoke Test

Check Pipe Flow

Clean Sampling Point.

a a a

Flush Pipe Network a a

Note:

Table 9 - Maintenance schedule for VLP detector

The frequency of maintenance checks could vary depending upon local codes and standards and the environment of the installation.

Caution:

While a VESDA Zone is isolated, no fire warnings will be issued by the VLP detector and any fire will go undetected. Prior to any maintenance or testing:

Inform appropriate supervising authority about the risk associated with isolating a

VESDA Zone.

Check to see if the VLP detector is also being used by third party

Ensure that any ancillary devices dependent on the VLP detector are enabled by the isolation before work is begun.

www.xtralis.com

31

Xtralis VESDA VLP Product Guide

Replacing the chassis/Air Inlet Pipe Manifold

Xtralis

VESDA

®

1.

Isolate unit by pressing the Isolate button on the zone configured display or by selecting

Isolate Zone from the Zone menu in VSC or VSM4. This isolates the outputs from the unit to a Fire Alarm Control Panel.

2.

Save node configuration by using VSC or VSM4, highlight the detector in the Device Tree

Window and select Save Node Configuration from the Device menu.

3.

Remove power by disconnecting the power cables.

4.

Remove the front panel by first opening the cover plate and screw covers, then unscrew the front cover.

A

Legend

A Cover plate screws

B Screw covers

B

Figure 22 - Removing front cover

5.

Disconnect data cables connecting the chassis assembly to the termination card, front panel modules (if fitted) and manifold.

D

Legend

C Termination cable

D Head processor card

E Flow sensor cable

F Scanner cable

F

E

C

Figure 23 - Remove data cables

6.

Unscrew the three manifold retaining screws

7.

Remove chassis, holding the chassis by the aspirator assembly. Release the two lower locking tabs by lifting the chassis upward and pulling outward. Use a screwdriver to assist with tab release.

32 www.xtralis.com

Xtralis

VESDA

® Xtralis VESDA VLP Product Guide

Figure 24 - Remove the chassis

Caution:

Care must be taken not to damage the cable running to the manifold.

Note:

The chassis consists of the Detection Chamber, head processor card and flow sensors. These are factory calibrated as a matched set and must not be separated.

Separating the set and replacing it with components from another VLP will cause the detector to malfunction. This will require the chassis to be returned to the factory.

8.

Disconnect the flow sensor lead.

9.

Unscrew manifold retaining screws.

Figure 25 - Removing pipe inlet manifold

10. Remove the manifold by sliding it downward, away from the pipe network.

11.

Attach the replacement manifold and chassis by reversing the procedure above.

12. Configure the node using VSC or VSM4 by highlighting the detector in the Device Tree window and highlighting ‘Restore Node Configuration’ from the device menu, or reprogram the detector using the LCD Programmer.

Note:

Data cables must be plugged and unplugged only after power has been removed.

Ensure all connectors are seated correctly before applying power to unit. Failure to observe this requirement may cause data corruption that requires factory recalibration.

www.xtralis.com

33

Xtralis VESDA VLP Product Guide

Internal Wiring for VLP

Xtralis

VESDA

®

The table below provides the cable loom interconnecting details inside the detector. Use the look up table in conjunction with the attached circuit diagram to assist with maintenance.

From To

Connector Name on CPU

Cable Name

Filter switch or X12 Fil SW

Termination or X1 Termination

# Pins

5

13

CPU card Filter Switch Card

CPU card Termination or X1 connector on termination card

CPU card Relays or X2 connector on termination card

CPU card Detection chamber

Do not disconnect

CPU card Detection chamber

CPU card Aspirator

CPU card Term or X1 connector on programmer or display

Relays or X3

Pre-amp or X9

Laser or X10

Aspirator or X11

Expansion or X2

Relays

Pre Amp

Laser

10

6 Wire ribbon

6

5

11

Note:

Note:

Table 10 - Interconnecting loom details

All connectors are polarized and can only be inserted one way into the socket.

Do not attempt to force the connector into its socket. If there is any difficulty, reverse the orientation of the connector before inserting again.

34 www.xtralis.com

Xtralis

VESDA

®

A

B

Xtralis VESDA VLP Product Guide

D

Legend

E

F

G

C

D

A

B

Detector chamber

Programmer module

Display module

Detector terminal card

Processor card

Aspirator

Flow sensor card

F

Figure 26 - Internal wiring diagram

E

G

C

www.xtralis.com

35

Xtralis VESDA VLP Product Guide

Spare Parts

Xtralis

VESDA

®

On larger sites having multiple detectors it is advisable to stock certain critical spare parts. A suggested list of spare parts with quantities is given below:

Part No.

Description

Number of detectors Installed to warrant ONE spare part

Normal Service

N/A

Mission Critical

N/A VSP-000 Blank Plate, non-EMC painted, with

VESDA logo

VSP-001 LCD Programmer

VSP-002 Display Module

VSP-005 Filter Cartridge

VSP-006 VLP detector chassis assembly complete with manifold

VSP-011 Recess Mounting Kit for VLP

VSP-013 Detector Cover Assembly complete with

EMC shields

VSP-014 7-relay termination card

VSP-015 VLP detector Aspirator Assembly

VSP-019 Filter Cover

VSP-100 Blank Plate with FOK LEDs and Logo

VSP-200 Blank Plate, EMC Painted, without Logo

50

50

20

50

N/A

N/A

50

N/A

N/A

If Applicable

If Applicable

20

20

10

20

N/A

N/A

20

20

N/A

If Applicable

If Applicable

Table 11 - Suggested spare parts stock

36 www.xtralis.com

Xtralis

VESDA

®

Index

A

Action

.................................................. 7

Action relay

........................................ 16

Action Threshold

................................. 14

Air flow normalizing

............................. 31

Air flow Thresholds

.............................. 14

Airflow fault

.......................................... 7

Alarm Delays

Alert

Fire 1

.............................................. 14

............................................. 14

Fire 2

............................................. 14

Alarm level

Action

Alert

.............................................. 7

................................................ 7

Fire 1

............................................... 7

Fire 2

............................................... 7

Alarm levels

.......................................... 7

Alert

..................................................... 7

Alert relay

........................................... 16

Alert Threshold

................................... 14

Aspirator

.............................................. 3

Aspirator Speed

.................................. 14

AutoLearn

........................................... 14

B

Back up battery

................................... 28

Bar graph

............................................. 7

Battery back up

................................... 28

C

Change-over Times

.............................. 14

Chassis/Air Inlet Pipe Manifold

.............. 32

Chassis/Air Inlet Pipe Replacement

....... 32

Xtralis VESDA VLP Product Guide

Check Pipe Flow

.................................. 31

Check Pipe Network

............................. 31

Clean Sampling Point

........................... 31

Communications

................................. 15

Connecting VLP to Pipe Network

........... 22

Contact Us

............................................. ii

Conventions

.......................................... ii

D

Default settings

................................... 14

Delay

............................................ 14, 15

Delay Times

........................................ 14

Detection chamber

................................. 4

Detector Chamber

.................................. 3

Detector Front Cover

.............................. 6

Dilution

.............................................. 15

Dimensions

......................................... 10

Dimensions - VLP

................................ 12

Display - Relay Card

............................. 15

Display Module

.................................. 5, 6

E

Exhaust Air

......................................... 23

External Reset

..................................... 17

F

Fault

Minor

............................................... 6

System

Urgent

............................................ 6

............................................. 6

Zone

............................................... 6

Fault lights

.......................................... 29

Faults LED

............................................ 7

www.xtralis.com

37

Xtralis VESDA VLP Product Guide

Features list

.......................................... 3

Filter fault

............................................. 7

Filter Inspection

.................................. 31

Filter Service Interval

........................... 14

Fire 1

................................................... 7

Fire 1 relay

.......................................... 16

Fire 1 Threshold

.................................. 14

Fire 2

................................................... 7

Fire 2 relay

.......................................... 16

Fire 2 Threshold

.................................. 14

Fire and OK LEDs

.................................. 5

First Stage Air Filter

............................... 3

Flow Control

....................................... 14

Flush Pipe Network

.............................. 31

FOK

..................................................... 5

G

GPI connection

.................................... 25

GPI Functions

..................................... 17

H

I

Health Check

....................................... 15

High Minor

.......................................... 14

High Urgent

........................................ 14

Holidays

............................................. 14

Inlet Pipes

........................................... 22

Instant Fire

......................................... 14

Internal Wiring

..................................... 34

Introduction

.......................................... 3

Inverted Reset

..................................... 17

IP Rating

............................................. 10

Isolate

................................................ 17

Isolate button

........................................ 8

Isolate LED

........................................... 7

Isolate relay

........................................ 16

38

Xtralis

VESDA

®

L

Laser detection chamber

........................ 4

LCD Programmer

................................... 5

LCD programmer

................................... 8

Low Minor

........................................... 14

Low Urgent

......................................... 14

M

Mains OK

............................................ 17

Maintenance

........................................ 31

Minor fault

............................................ 6

Minor fault relay

................................... 16

Mode button

.......................................... 8

Mode/Test button

................................... 8

N

Network Delay

..................................... 15

Network fault

......................................... 7

Normalizing air flow

............................. 31

Numerical Display

.................................. 8

O

OK LED

................................................ 7

Open - ended Loop

.............................. 15

Operating Temperature

......................... 10

Optical surfaces

.................................... 4

P

Pipe Inlet Manifold

................................. 3

Pipe Integrity Smoke Test

..................... 31

Pipe Size

............................................. 10

Power

................................................. 17

Power Consumption

............................. 10

Power fault

............................................ 7

Power Source

...................................... 27

Power Supply

...................................... 31

www.xtralis.com

Xtralis

VESDA

®

Powering up

........................................ 29

Preferred Port

..................................... 15

Preliminary Systems Check

.................. 31

Programmer

.......................................... 8

Push Button Keys

.................................. 8

Xtralis VESDA VLP Product Guide

Threshold Indicators

.............................. 7

Threshold Setting

................................ 11

U

R

Reference Zone No.

............................. 15

Relay Set

............................................ 15

Relays

.......................................... 10, 15

Relays - default settings

....................... 16

remote location

Display Module - Introduction to VLP Detector

6

Reset Button

....................................... 29

Reset button

......................................... 8

Reset+Isolate

...................................... 17

S

Sampling Pipe Network

........................ 10

Second Stage Filter

................................ 4

Sensitivity

............................................. 8

Silence button

....................................... 8

Smoke Change

.................................... 14

Smoke Level

....................................... 14

Smoke level

.......................................... 8

Socket - VESDAnet

................................ 8

Spare parts

......................................... 36

Specifications

..................................... 10

Standby Mode

..................................... 17

Starting Up

......................................... 29

System fault

...................................... 6, 7

UL Version

.......................................... 15

Ultra clean air

........................................ 4

Unlatch relays

..................................... 29

Urgent Fault

........................................ 16

Urgent fault

....................................... 6, 7

Use Night-time Threshold

..................... 17

V

VESDAnet

............................................. 8

VESDAnet closed Loop

........................ 25

VESDAnet Terminals

............................ 24

VLP

Components

..................................... 9

Default settings

................................ 14

Exploded view

................................... 9

Maintenance

Mounting

................................... 31

........................................ 19

Specifications

.................................. 10

Systems Check

............................... 31

Wiring connections

........................... 24

Voltage

............................................... 10

W

Weekend times

Weight

Z

.................................... 14

................................................ 10

Wiring Connections

............................. 24

T

Zone fault

......................................... 6, 7

Zone number

......................................... 8

Termination Card

................................. 24

www.xtralis.com

39

Xtralis VESDA VLP Product Guide Xtralis

VESDA

®

40 www.xtralis.com

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals