Promax PROLITE-24 Fiber Test UTP Optical power meter, VFL and Ethernet tester User's Guide

Add to My manuals
1 Pages

advertisement

Promax PROLITE-24 Fiber Test UTP Optical power meter, VFL and Ethernet tester User's Guide | Manualzz

PROLITE-24

User’s Guide

nm

Fiber Test UTP

Mini Optical Power Meter, Visual Fault Locator

& RJ45 connection tester dBm

PROLITE-24

Description of the controls and elements.

>2s REF

UNIT

LED

LIGHT

VFL

P R O L I T E -

24

Fiber Test UTP www.promaxelectronics.com

1

2

3

Introduction

The PROLITE-24 is a multifunctional optical power meter. It integrates the functions of a Visual Fault Locator (VFL) and RJ45 Ethernet

Cable Tester. It also has a flashlight. Its small size (pocket size) makes it a very lightweight, strong and durable tool. It is an instrument that is specially suitable for applications such as FTTx broadband installation and maintenance tests and comprehensive tests of fiber optic network cable.

Description of the controls and elements.

nm dBm

>2s REF

UNIT

LED

LIGHT

VFL

P R O L I T E 24

Fiber Test UTP

4

5

6

1

2

Short press to turn on / long press to turn off (Short press to turn off the

Auto-off function when starting up); In user calibration mode, short press to save the current calibration value.

Backlight switch used to turn on/off the backlight.

3

4

5

Switches VFL on/off, short press to switch CW/1Hz / 2Hz; Short press in user calibration mode to decrease 0.05dB.

Short press to switch measurement unit among dBm, dB and mW; Long press to set current measurement value as reference value; Short press in user calibration mode to increase 0.05dB.

Short press to switch the measurement unit between dBm, dB and mW;

Long press to select current measurement value as reference value; Short press in calibration mode to increase 0.05 dB.

6 Select measurement wavelength: 850/1300/1310/1490/1550/1625/1650 nm

www.promaxelectronics.com

PROLITE-24

0 DG0414_ 11-22

1

5

2

4

3

1 VFL Interface.

2 LED flashlight.

3 Optical Power Meter Interface.

4 Type-C USB (Internal control).

5

RJ45 interface and RJ45 far-end module, used for network line sequence pairing.

Specifications

OPTICAL POWER METER

Detector type

Calibrated Wavelength

Measurement range

Frequency identification

Resolution

Accuracy

Measurement units

Measurement modes

Optical connector

VISUAL FAULT LOCATOR

Output wavelength

Output power

Output mode

Optical port

TESTER ETHERNET

Connection

Operating mode

OTHERS

Display

Flashlight

Calibration

POWER SUPPLY

MECHANICAL FEATURES

Dimensions

Weight

InGaAs

850 / 1300 / 1310 / 1490 / 1550 / 1625 / 1650 nm

From -70 dBm to +6 dBm

270 Hz / 330 Hz / 1 kHz / 2 kHz

0.01 dBm

± 5 % dBm / dB / mW

Normal or based on a user-defined reference value

2.5 mm universal interface (support FC, SC and ST connectors)

650 nm ±3 nm

2 mW

CW / 1 Hz / 2 Hz

2.5 mm universal interface (support FC, SC and ST connectors)

Connection of the ends of the ethernet cable to the remote module, and to the equipment

Sequential test of the 8 wires of the RJ-45 cable

Backlit LCD

LED flashlight

Selectable calibration mode

3 x AAA batteries

Auto power-off 10 minutes

67 (W.) x 104 (H.) x 28 (D.) mm

140 gr

www.promaxelectronics.com