Package Checklist
The Moxa EtherDevice Router is shipped with the following items. If any of these items is missing or damaged, please contact your customer service representative for assistance.
• 1 EtherDevice Router
• Hardware Installation Guide
• CD-ROM with User’s Manual and Windows utility
• Moxa product warranty statement
• RJ45 to DB9 console port cable
• Protective caps for unused ports
Features
Advanced Industrial Networking Capability
• Router/Firewall/VPN all in one.
• High performance Gigabit copper/fiber combo port.
• Supports 1 WAN, 1 LAN, and 1 user-configurable WAN or DMZ interface (EDR-G903).
• Supports 1 WAN and 1 LAN (EDR-G902)
• Firewall with Quick Automation Profile for Fieldbus protocols.
• Network address translation (N-to-1, 1-to-1, and port forwarding).
• Intelligent PolicyCheck and SettingCheck tools.
• -40 to 75°C operating temperature (T models).
- 2 -
Panel Views of EtherDevice Router
EDR-G903 Front Panel:
1. WAN1, DMZ/WAN2, LAN port:
10/100/1000 BaseT(X) or
100/1000Base SFP slot combo ports
2. Power input PWR1 LED
3. Power input PWR2 LED
4. Fault LED
5. 10/100/1000BaseT(X) LED indicator
6. LED for DMZ/WAN2 port
EDR-G902 Front Panel:
1. WAN, LAN port 10/100/1000
BaseT(X) or 100/1000Base SFP slot combo ports
2. Power input PWR1 LED
3. Power input PWR2 LED
4. Fault LED
5. 10/100/1000BaseT(X) LED indicator
- 3 -
Mounting Dimensions
Top Panel:
1. Grounding screw
2. 4-pin terminal block for PWR 1,
PWR 2
3. 4-pin terminal block for DI and
Relay
4. RS-232 console port
Rear Panel:
1. Terminal block
2. DIN-Rail kit
- 4 -
Unit = mm (inch)
DIN-Rail Mounting
The aluminum DIN-Rail attachment plate should already be fixed to the back panel of the EtherDevice Router when you take it out of the box. If you need to reattach the DIN-Rail attachment plate to the EtherDevice
Router, make sure the stiff metal spring is situated towards the top, as shown in the following figures.
STEP 1—Insert the top of the
DIN-Rail into the slot just below the stiff metal spring.
STEP 2—The DIN-Rail attachment unit will snap into place as shown in the following illustration.
To remove the EtherDevice Router from the DIN-Rail, simply reverse
Steps 1 and 2 above.
Wiring Requirements
WARNING
Do not disconnect modules or wires unless power has been switched off or the area is known to be non-hazardous. The devices may only be connected to the supply voltage shown on the type plate. The devices are designed for operation with a
Safety Extra-Low Voltage. Thus, they may only be connected to the supply voltage connections and to the signal contact with the
Safety Extra-Low Voltages (SELV) in compliance with IEC950/
EN60950-1/ VDE0805.
ATTENTION
This unit is a built-in type. When the unit is installed in another piece of equipment, the equipment enclosing the unit must comply with fire enclosure regulation IEC 60950-1/EN60950-1
(or similar regulation).
- 5 -
ATTENTION
Safety First!
Be sure to disconnect the power cord before installing and/or wiring your Moxa EtherDevice Router.
Calculate the maximum possible current in each power wire and common wire. Observe all electrical codes dictating the maximum current allowable for each wire size.
If the current goes above the maximum ratings, the wiring could overheat, causing serious damage to your equipment.
Please read and follow these guidelines:
• Use separate paths to route wiring for power and devices. If power wiring and device wiring paths must cross, make sure the wires are perpendicular at the intersection point.
NOTE: Do not run signal or communications wiring and power wiring through the same wire conduit. To avoid interference, wires with different signal characteristics should be routed separately.
• You can use the type of signal transmitted through a wire to determine which wires should be kept separate. The rule of thumb is that wiring sharing similar electrical characteristics can be bundled together
• You should separate input wiring from output wiring
• We advise that you label the wiring to all devices in the system.
Grounding the Moxa EtherDevice Router
Grounding and wire routing help limit the effects of noise due to electromagnetic interference (EMI). Run the ground connection from the ground screw to the grounding surface prior to connecting devices.
ATTENTION
This product is intended to be mounted to a well-grounded mounting surface such as a metal panel.
- 6 -
Wiring the Relay Contact
The EtherDevice Router has one set of relay outputs. This relay contact uses one contacts of the terminal block on the EtherDevice Router’s top panel. Refer to the next section for detailed instructions on how to connect the wires to the terminal block connector, and how to attach the terminal block connector to the terminal block receptor.
In this section, we illustrate the meaning of the contact used to connect the relay contact.
FAULT:
The two right contacts of the 4-pin terminal block connector are used to detect user-configured events. The two wires attached to the fault contacts form an open circuit when a user-configured event is triggered. If a user-configured event does not occur, the fault circuit remains closed.
Wiring the Redundant Power Inputs
The EtherDevice Router has two sets of power inputs—power input 1 and power input 2. The top and front views of one of the terminal block connectors are shown here.
STEP 1: Insert the negative/positive DC wires into the V-/V+ terminals, respectively.
STEP 2: To keep the DC wires from pulling loose, use a small flat-blade screwdriver to tighten the wire-clamp screws on the front of the terminal block connector.
STEP 3: Insert the plastic terminal block connector prongs into the terminal block receptor, which is located on the EtherDevice
Router’s top panel.
- 7 -
Wiring the Digital Inputs
The EtherDevice Router has one set of digital input, DI. The DI consists of two left contacts of the 4-pin terminal block connector on the EtherDevice
Router’s top panel, which are used for the DC inputs. The top and front views of one of the terminal block connectors are shown here.
STEP 1: Insert the negative (ground)/positive
DI wires into the ┴/I terminals, respectively.
STEP 2: To keep the DI wires from pulling loose, use a small flat-blade screwdriver to tighten the wire-clamp screws on the front of the terminal block connector.
STEP 3: Insert the plastic terminal block connector prongs into the terminal block receptor, which is located on the EDR-G903’s top panel.
Communication Connections
Each EtherDevice Router has 2 types of communication port:
1. 1 RJ45 console port (RS-232 interface)
2. 3 combination 10/100/1000T(X)/1000BaseSFP ports (EDR-G903)
3. 1 combination 10/100/1000T(X)/1000BaseSFP port and 1
10/100/1000T(X) Ethernet port (EDR-G902)
RS-232 Connection
The EtherDevice Router has one RS-232 (10-pin RJ45) console port, located on the top panel. Use either an RJ45-to-DB9 (see the cable following wiring diagrams) to connect the EtherDevice Router’s console port to your PC’s COM port. You may then use a console terminal program, such as Moxa PComm Terminal Emulator, to access the EtherDevice
Router’s console configuration utility.
RJ45 (10-pin) Console Port Pinouts
Pin
1
6
7
8
2
3
4
5
9
10
Description
---
DSR
RTS
---
TxD
RxD
GND
CTS
DTR
---
- 8 -
RJ45 (10-pin) to DB9 (F) Cable Wiring
10/100/1000BaseT(X) Ethernet Port Connection
The 10/100/1000BaseT(X) ports located on Moxa EtherDevice Router’s front panel are used to connect to Ethernet-enabled devices. Most users will choose to configure these ports for Auto MDI/MDI-X mode, in which case the port’s pinouts are adjusted automatically depending on the type of Ethernet cable used (straight-through or cross-over), and the type of device (NIC-type or HUB/Switch-type) connected to the port.
In what follows, we give pinouts for both MDI (NIC-type) ports and MDI-X
(HUB/Switch-type) ports. We also give cable wiring diagrams for straight-through and cross-over Ethernet cables.
10/100Base T(x) RJ45 Pinouts
8-pin RJ45 MDI Port Pinouts MDI-X Port Pinouts
Pin Signal Pin Signal
1
2
Tx+
Tx-
1
2
Rx+
Rx-
3
6
Rx+
Rx-
3
6
Tx+
Tx-
1000BaseT RJ45 Pinouts
Pin
1
2
3
4
5
6
7
8
MDI
BI_DA+
BI_DA-
BI_DB+
BI_DC+
BI_DC-
BI_DB-
BI_DD+
BI_DD-
MDI-X
BI_DB+
BI_DB-
BI_DA+
BI_DD+
BI_DD-
BI_DA-
BI_DC+
BI_DC-
- 9 -
RJ45 (8-pin) to RJ45 (8-pin) Straight-Through Cable Wiring
RJ45 (8-pin) to RJ45 (8-pin) Cross-Over Cable Wiring
100 BaseFX or 1000BaseSFP Fiber Port
The Gigabit Ethernet ports on the EtherDevice Router are SFP slots, which require 100BaseFX SFP or Gigabit mini-GBIC fiber transceivers to work properly. Moxa provides complete transceiver models for various distance requirements.
The concept behind the LC port and cable is quite straightforward.
Suppose you are connecting devices I and II. Unlike electrical signals, optical signals do not require a circuit in order to transmit data.
Consequently, one of the optical lines is used to transmit data from device
I to device II, and the other optical line is used to transmit data from device II to device I, for full-duplex transmission.
Remember to connect the Tx (transmit) port of device I to the Rx (receive) port of device II, and the Rx (receive) port of device I to the Tx (transmit) port of device II. If you make your own cable, we suggest labeling the two sides of the same line with the same letter (A-to-A and B-to-B, as shown below, or A1-to-A2 and B1-to-B2).
LC-Port Pinouts LC-Port to LC-Port Cable Wiring
- 10 -
ATTENTION
This is a Class 1 Laser/LED product. To avoid causing serious damage to your eyes, do not stare directly into the Laser Beam.
LED Indicators
The front panel of the Moxa EtherDevice Router contains several LED indicators. The function of each LED is described in the following table:
LED Color
PWR1
PWR2
FAULT
10/100/1000M
WAN/DMZ
(EDR-G903 only)
AMBER
AMBER
RED
AMBER
GREEN
AMBER
GREEN
State Description
On
Off
On
Off
On
Off
On
Blinking
Off
Power is being supplied to power input P1 on the main module.
Power is not being supplied to power input P1 on the main module.
Power is being supplied to power input P2 on the main module.
Power is not being supplied to power input P2 on the main module.
When a user-configured event is triggered.
When a user-configured event has not been triggered.
TP or FX port’s 10/100 Mbps link is active.
Data is being transmitted at
10/100 Mbps.
TP or FX port’s 10/100 Mbps link is inactive.
On
Blinking
Off
On
TP or FX port’s 1000 Mbps link is active.
Data is being transmitted at 1000
Mbps.
TP or FX port’s 1000 Mbps link is inactive.
The WAN2/DMZ port is set to the
“WAN” function.
Off The WAN2/DMZ port is disabled.
On
The WAN2/DMZ port is set to the
“DMZ” function.
Off The WAN2/DMZ port is disabled.
- 11 -
Specifications
Technology
Standards
Protocols
Flow Control
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 802.3ab for 1000BaseT(X)
IEEE 802.3z for 1000BaseX
SNMPv1/v2c/v3, DHCP Server/Client, TFTP,
NTP, HTTP, HTTPS, Telnet, SSH, Syslog, SMTP,
LLDP, PPPoE, PPTP, Dynamic DNS, QoS (Quality of Service)
IEEE 802.3x flow control, back pressure flow control
Interface
RJ45 Ports
Fiber Ports
LED Indicators
Alarm Contact
Digital Input
10/100/1000BaseT(X) auto negotiation speed
100/1000BaseSFP slot
PWR1, PWR2, FAULT, 10/100/1000M,
DMZ/WAN
One relay output with current carrying capacity of 1 A @ 24 VDC
1 input
• For state “1”: +13 to +30 V
• For state “0”: -30 to +3 V
• Max. input current: 8 mA
Power
Input Voltage
Connection
Overload Current
12/24/48 VDC redundant dual inputs
Removable terminal block
Present
Protection
Reverse Polarity
Protection
Present
Physical Characteristics
Housing Metal
Dimensions (W × H × D) 51.2 × 152 × 131.1 mm (2.02 × 5.98 × 5.16 in)
Weight 1250 g
Installation
Environmental Limits
DIN-Rail mounting
Operating Temperature 0 to 60°C (32 to 140°F), standard models
-40 to 75°C (-40 to 167°F) for -T models
Storage Temperature -40 to 85°C (-40 to 185°F)
Operating Humidity 5 to 95% (non-condensing)
Regulatory Approvals
Safety UL 508
EMI FCC Part 15, CISPR (EN55022); class A
EMS
Shock
Free Fall
Vibration
WARRANTY
IEC 61000-4-2 (ESD), level 3;
IEC 61000-4-3 (RS), level 3;
IEC 61000-4-4 (EFT), level 3;
IEC 61000-4-5 (Surge), level 3;
IEC 61000-4-6 (CS), level 3
IEC60068-2-27
IEC60068-2-32
IEC60068-2-6
5 years
- 12 -
Technical Support Contact Information www.moxa.com/support
Moxa Americas:
Toll-free: 1-888-669-2872
Tel: 1-714-528-6777
Fax: 1-714-528-6778
Moxa Europe:
Tel: +49-89-3 70 03 99-0
Fax: +49-89-3 70 03 99-99
Moxa China (Shanghai office):
Toll-free: 800-820-5036
Tel: +86-21-5258-9955
Fax: +86-21-5258-5505
Moxa Asia-Pacific:
Tel: +886-2-8919-1230
Fax: +886-2-8919-1231
- 13 -
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement