- Computers & electronics
- Computer components
- System components
- Processors
- ADFWeb
- HD67054M-160
- User manual
advertisement
▼
Scroll to page 2
of
34
User Manual M-Bus – Concentrator - Datalogger Document code: MN67054M_ENG Revision 1.021 Pagina 1 di 34 Industrial Electronic Devices User Manual Revision 1.021 English M-Bus – Concentrator – Datalogger (Order Codes: HD67054M-20 HD67054M-40 HD67054M-80 HD67054M-160 HD67054M-250) HD67054M-xxx For other M-Bus products: See also the following link: Converter M-Bus to www.adfweb.com?Product=HD67021 www.adfweb.com?Product=HD67022 www.adfweb.com?Product=HD67030 for Website information: www.adfweb.com?Product=HD67054M for Price information: www.adfweb.com?Price=HD67054M-20 www.adfweb.com?Price=HD67054M-40 www.adfweb.com?Price=HD67054M-80 www.adfweb.com?Price=HD67054M-160 www.adfweb.com?Price=HD67054M-250 Benefits and Main Features: Very easy to configure Electrical isolation Industrial temperature range: -40°C / 70°C (-40°F / 158°F) ADFweb.com Srl – IT31010 – Mareno – Treviso (RS232) (RS485) (Ethernet) Analyzer & Scanner M-Bus www.adfweb.com?Product=HD67031 Similiar Products Extender and Repeater, M-Bus www.adfweb.com?Product=HD67032 Gateway M-Bus / Modbus RTU www.adfweb.com?Product=HD67029M-232 www.adfweb.com?Product=HD67029M-485 (on RS232) (on RS485) Gateway M-Bus / Modbus TCP www.adfweb.com?Product=HD67044M Gateway M-Bus / PROFIBUS www.adfweb.com?Product=HD67053M Do you have an your customer protocol? See the following link: www.adfweb.com?Product=HD67003 Do you need to choose a device? do you want help? Ask it to the following link: www.adfweb.com?Cmd=helpme INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus – Concentrator - Datalogger Document code: MN67054M_ENG Revision 1.021 Pagina 2 di 34 Industrial Electronic Devices INDEX: INDEX UPDATED DOCUMENTATION REVISION LIST WARNING TRADEMARKS SECURITY ALERT CONNECTION SCHEME CHARACTERISTICS POWER SUPPLY FUNCTION MODES LEDS CONFIGURATION USE OF COMPOSITOR SW67054 NEW PROJECT / OPEN PROJECT SET COMMUNICATION M-BUS CSV FILE SOFTWARE & COMMANDS UPDATE DEVICE CHARACTERISTICS OF THE CABLE MECHANICAL DIMENSIONS ORDER CODES ACCESSORIES DISCLAIMER OTHER REGULATIONS AND STANDARDS WARRANTIES AND TECHNICAL SUPPORT RETURN POLICY PRODUCTS AND RELATED DOCUMENTS UPDATED DOCUMENTATION: Page 2 2 2 2 2 3 4 5 6 7 8 9 9 9 10 11 20 28 29 30 31 32 32 33 33 34 34 34 Dear customer, we thank you for your attention and we remind you that you need to check that the following document is: Updated Related to the product you own To obtain the most recently updated document, note the “document code” that appears at the top right-hand corner of each page of this document. With this “Document Code” go to web page www.adfweb.com/download/ and search for the corresponding code on the page. Click on the proper “Document Code” and download the updates. To obtain the updated documentation for the product that you own, note the “Document Code” (Abbreviated written "Doc. Code" on the label on the product) and download the updated from our web site www.adfweb.com/download/ REVISION LIST: Revision 1.000 1.001 1.010 1.020 1.021 Date 16/03/2010 06/04/2011 10/06/2011 19/09/2011 18/02/2013 Author Fl Fl Fl Fl Nt Chapter All All All All All Description First release version (1.000) Revision Software changed (1.100) Software changed (1.200) Added new chapters WARNING: ADFweb.com reserves the right to change information in this manual about our product without warning. ADFweb.com is not responsible for any error this manual may contain. TRADEMARKS: All trademarks mentioned in this document belong to their respective owners. ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus – Concentrator - Datalogger Document code: MN67054M_ENG Revision 1.021 Pagina 3 di 34 Industrial Electronic Devices SECURITY ALERT: GENERAL INFORMATION To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device are required for each individual application, legal and safety regulation. The same applies also when using accessories. INTENDED USE Machines and systems must be designed so the faulty conditions do not lead to a dangerous situation for the operator (i.e. independent limit switches, mechanical interlocks, etc.). QUALIFIED PERSONNEL The device can be used only by qualified personnel, strictly in accordance with the specifications. Qualified personnel are persons who are familiar with the installation, assembly, commissioning and operation of this equipment and who have appropriate qualifications for their job. RESIDUAL RISKS The device is state of the art and is safe. The instrument can represent a potential hazard if they are inappropriately installed and operated by personnel untrained. These instructions refer to residual risks with the following symbol: This symbol indicates that non-observance of the safety instructions is danger for people to serious injury or death and / or the possibility of damage. CE CONFORMITY The declaration is made by us. You can send an email to [email protected] or give us a call if you need it. ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus – Concentrator - Datalogger Document code: MN67054M_ENG Revision 1.021 Pagina 4 di 34 Industrial Electronic Devices CONNECTION SCHEME: Figure 1: Connection scheme for HD67054M-xxx ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus – Concentrator - Datalogger Document code: MN67054M_ENG Revision 1.021 Pagina 5 di 34 Industrial Electronic Devices CHARACTERISTICS: The HD67054M-xxx is a M-Bus Concentrator. It allow to read data from the M-Bus meters and store the desired values into a CSV file. This file can be downloaded with a specific free software furnished with the device or with some simple commands via a Point-to-Point connection (RS232, Dialup/GSM/ISDN Modem). The readings are made automatically from the Concentrator at predetermined times. It allows the following characteristics: Electrical isolation between Serial and M-Bus; Mountable on Rail DIN; Temperature range -40°C to 70°C. At the Gateway can be connected up to 250 standard M-Bus devices. This number depends of the code expressed by the xxx number: HD67054M-20 support up to 20 M-Bus devices; HD67054M-40 support up to 40 M-Bus devices; HD67054M-80 support up to 80 M-Bus devices; HD67054M-160 support up to 160 M-Bus devices; HD67054M-250 support up to 250 M-Bus devices. In the case of HD67054M-160 the device must be mounted on 35mm DIN rail which is horizontally mounted on a wall or cabinet backplate. To avoid obstructions to the airflow around the unit it is recommended to not cover the paths of air. In the case of HD67054M-250 the device must be mounted on 35mm DIN rail which is horizontally mounted on a wall or cabinet backplate. This unit have a fan in the top of the enclosure. To avoid obstructions to the airflow around the unit it is recommended to not cover the paths of air. Take care to not cover the fan. It is recommended to put the device into a ventilated cabinet. ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus – Concentrator - Datalogger Document code: MN67054M_ENG Revision 1.021 Pagina 6 di 34 Industrial Electronic Devices POWER SUPPLY: The devices can be powered at 15…21V AC and 18…35V DC. The consumption depends to the code of the device. For more details see the two tables below. VAC VDC Vmin Vmax Vmin Vmax 15V 21V 18V 35V Consumption at 24V DC: Device No Load [W/VA] Full Load [W/VA]* HD67054M 4 HD67054M-40 5 HD67054M-80 HD67054M-160 3.5 8 14 HD67054M-250 30 * This value is with all the Slave M-Bus devices of the code (20, 40, 80, 160, 250) connected to the line Caution: Not reverse the polarity power HD67054M-xxx ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus – Concentrator - Datalogger Document code: MN67054M_ENG Revision 1.021 Pagina 7 di 34 Industrial Electronic Devices FUNCTION MODES: The device has got two functions mode depending of the position of the ‘Jumper1’: The first, without jumper inserted (factory setting), is used for the normal working of the device. The second, with jumper inserted, is used for upload the Firmware/Project. For the operations to follow for the updating (see ‘UPDATE DEVICE’ section). According to the functioning mode, the LEDs will have specifics functions (see ‘LEDS’ section). ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus – Concentrator - Datalogger Document code: MN67054M_ENG Revision 1.021 Pagina 8 di 34 Industrial Electronic Devices LEDS: The device has got six LEDs that are used to give information of the functioning status. The various meanings of the LEDs are described in the table below. LED 1: Device State Normal Mode Boot Mode Blink slowly Off Blink slowly: Some data is arriving to the port 2: M-Bus Communication Off Off: No data is arriving to the port On: In the last scan some slave haven’t replied 3: Scan Results Off Off: The Last scan was completed with success On: A Modem is correctly connected (only if is used Dial-UP or ISDN modem) 4: Modem State Off Off: No Modem Connected 5: Device State Off Blink quickly On: A scan is running 6: Scan State Off Off: No scan is being made ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus – Concentrator - Datalogger Document code: MN67054M_ENG Revision 1.021 Pagina 9 di 34 Industrial Electronic Devices CONFIGURATION: You need Compositor SW67054 software on your PC in order to perform the following: Define the parameter of M-Bus line; Define the map of M-Bus devices to be scan; Update the device. USE OF COMPOSITOR SW67054: To configure the Gateway, use the available software that runs with Windows, called SW67054. It is downloadable on the site www.adfweb.com and its operation is described in this document. When launching the SW67054 the right window appears (Fig. 2). Figure 2: Main window for SW67054 NEW PROJECT / OPEN PROJECT: The “New Project” button creates the folder which contains the entire device configuration. A device configuration can also be imported or exported: To clone the configurations of a M-Bus Concentrator in order to configure another device in the same manner, it is necessary to maintain the folder and all its contents; To clone a project in order to obtain a different version of the project, it is sufficient to duplicate the project folder with another name and open the new folder with the button “Open Project”; When a new project is created or an existent project is open, it will be possible to access the various sections of the software: “Set Communication”; “M-Bus”; “Update Device”. ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus – Concentrator - Datalogger Document code: MN67054M_ENG Revision 1.021 Pagina 10 di 34 Industrial Electronic Devices SET COMMUNICATION: This section define the fundamental communication parameters of M-Bus and Serial. By Pressing the “Set Communication” button from the main window for SW67054 (Fig. 2) the window “Set Communication” appears (Fig. 3). The window is divided in three sections, one for the Serial, one for the Data Logger and the other for the M-Bus. In the “Serial” section it is possible to select the mode used for download the .CSV file. The possibilities are: “Not Used”: It allows to download the file directly with a PC connected with a serial cable to the device; “Modem Dial-Up”: It allows to download the file via Analog Modem connection. For use this you have to use an external analog modem; “Modem GSM”: It allows to download the file via GSM connection. For use this you have to use an external GSM modem; “Modem ISDN”: It allows to download the file via ISDN Modem connection. For use this you have to use an external ISDN modem. Figure 3: “Set Communication” window In the “M-Bus” section it is possible to select when the concentrator makes the requests to the slaves. The possibilities are: “Every “Every “Every “Every “Every ¼ Hour”: The scanning is done every 15 minutes; ½ Hour”: The scanning is done every 30 minutes; Hour”: The scanning is done every 60 minutes; Day”: In this case you have to choose the hour and minute in which the scan will be done; Week”: In this case you have to choose the day of week, hour, minute in which the scan will be done; ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus – Concentrator - Datalogger Document code: MN67054M_ENG Revision 1.021 Pagina 11 di 34 Industrial Electronic Devices “Every Month”: In this case you have to choose the day, hour, minute in which the scan will be done; “Every Year”: In this case you have to choose the month, day, hour, minute in which the scan will be done. In the “Data Logger” section it is possible to select if enable or not the Log by checking or un-checking the field “Enable Log”. If enabled the gateway saves the first day of the month the data. These 12 logs are readable by sending the commands written in the section “Software & Commands”. ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus – Concentrator - Datalogger Document code: MN67054M_ENG Revision 1.021 Pagina 12 di 34 Industrial Electronic Devices M-BUS By Pressing the “M-Bus” button from the main window for SW67054 (Fig. 2) the window “M-Bus Network” appears (Fig. 4). SECTION BAUDRATES: In the section “Baudrates” it is possible to create various group of devices based on Baudrate and Parity. After that, pressing the “ADD GROUP” button, a new group appears in the left side of the window. In order to modify a created group it is necessary to select the desired group , change the wrong items and then press the “MODIFY GROUP” button. Figure 4: “M-Bus Network” window ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus – Concentrator - Datalogger Document code: MN67054M_ENG Revision 1.021 Pagina 13 di 34 Industrial Electronic Devices SECTION NODES: In the section “M-Bus Node” it is possible to create the nodes of a specific ‘Group’. In order to create a new node it is necessary to select which address use, selecting “ID Node MBus” or “Secondary Address”, to makes the requests and then insert the “Primary Address” (from 1 to 250) or the “Secondary Address” (from 0 to 99999999) of M-Bus device. If you select “Description” it is possible to write a short description of the node in the right field. Otherwise if “Data” is selected it is possible to fill the fields with the values of an apartament or else. The fields are: User, Scale, Floor, Flat. The values of “Description” or “Data” are used in the CSV file for identify the variables stored. If the field “Send SND_NKE” is checked, the Gateway send the “SND_NKE” frame to start the communication. In the field “Send Reset App.” is checked the gateway send the “Application Reset” command to the slave. After that, pressing the “ADD NODE” button, a new node appears in the left side of the window. In order to modify a created node it is necessary to select the desired node, change the wrong items and then press the “MODIFY NODE” button. ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus – Concentrator - Datalogger Document code: MN67054M_ENG Revision 1.021 Pagina 14 di 34 Industrial Electronic Devices SECTION VARIABLES: Selecting the desired node it is possible to add the variables. In order to create a new variable it is necessary to fill these items: To use the created variable the field “Enable Variable” must be checked. If you have created a variable but for the moment it is unused it is possible to uncheck the field “Enable Variable” without delete it; In the field “Description” it is possible to write a description of the variable (it isn’t a necessary information, it helps the readability of the tree of network); The field “Type of Data” is used to select the unit of measure; If the field “Type of Data” is “VIF is in ASCII” you have to write in the field “VIF ASCII str” the correct string of VIF; In the field “Function Field” it is necessary to select the type of data; The field “Dimension” is used to select the dimension of the variable (8, 16, 24, 32, 32 real, 48, 64 bit, Variable length); If the field “Dimension” is “Variable Length” in the field “Length” you have to insert the length of data; In the field “Unit” if it is necessary it is possible to select the unit of that variable. The Unit is used for indicates from which device the data come; In the field “Storage Number” if it is necessary it is possible to insert the value of storage counter of that variable. With this field the slave can indicate and transmit various stored counter states or historical values, in the order in which they occur; ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus – Concentrator - Datalogger Document code: MN67054M_ENG Revision 1.021 Pagina 15 di 34 Industrial Electronic Devices In the field “Tariff” if it is necessary it is possible to insert the value of the tariff of that variable. The Tariff is used for indicates from which device the data come; In the field “VIFE” it is possible to select a sub-type of “Type of Data”. Having completed this fields, to add the variable the button “ADD VARIABLE” must be pressed. In order to modify a created variable it is necessary to select the desired variable, change the wrong items and then press the “MODIFY VARIABLE” button. ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus – Concentrator - Datalogger Document code: MN67054M_ENG Revision 1.021 Pagina 16 di 34 Industrial Electronic Devices SECTION DELETE ITEMS: If it is necessary to delete a group, a node or a variable, you have to select the node or the variable and then press the “DELETE ITEM” button. ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus – Concentrator - Datalogger Document code: MN67054M_ENG Revision 1.021 Pagina 17 di 34 Industrial Electronic Devices Possible choices for the fields used to create a variable: Type of Data: |_Energy (Wh) |_Energy (J) |_Volume (m3) |_Mass (Kg) |_On Time |_Operating Time |_Power (W) |_Power (J/h) |_Volume Flow (m3/h) |_Volume Flow Ext. (m3/min) |_Volume Flow Ext. (m3/s) |_Mass Flow (Kg/h) |_Flow Temperature (°C) |_Return Temperature (°C) |_Temperature Difference (K) |_External Temperature (°C) |_Pressure (bar) |_Averaging Duration |_Actuality Duration |_Type of data in VIFE |_Time Point |_VIF is in ASCII |_Unit for H.C.A. |_Fabrication No |_(Enhaced) Identification |_Bus Address ADFweb.com Srl – IT31010 – Mareno – Treviso Function Field: |_Instantaneous Value |_Minimum Value |_Maximum Value |_Value During Error State Dimension (bit): |_8 |_16 |_24 |_32 |_32 real |_48 |_64 |_Variable Length INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus – Concentrator - Datalogger Document code: MN67054M_ENG Revision 1.021 Pagina 18 di 34 Industrial Electronic Devices VIFE: |_ Not Selected |_ Credit of the nominal local legal currency units |_ Debit of the nominal local legal currency units |_ Access Number (transmission count) |_ Medium (as in fixed header) |_ Manufacturer (as in fixed header) |_ Parameter set identification |_ Model/Version |_ Hardware Version # |_ Firmware Version # |_ Software Version # |_ Customer Location |_ Customer |_ Access Code User |_ Access Code Operator |_ Access Code System Operator |_ Access Code Developer |_ Password |_ Error flags (binary) |_ Error mask |_ Digital Output (binary) |_ Digital Input (binary) |_ Baudrate [Baud] |_ response delay time [bittimes] |_ Retry |_ First storage # for cyclic storage |_ Last storage # for cyclic storage |_ Size of storage block |_ Storage interval [sec(s)..day(s)] |_ Storage interval month(s) |_ Storage interval year(s) |_ Duration since last readout[sec(s)..day(s)] |_ Start (date/time) of tariff |_ Duration of tariff (nn=01..11:min to day) |_ Period of tariff [sec(s) to day(s)] ADFweb.com Srl – IT31010 – Mareno – Treviso |_ Period of tariff months(s) |_ Period of tariff year(s) |_ dimensionless/ no VIF |_ Volts |_ Ampere |_ Reset counter |_ Comulation counter |_ Control signal |_ Day of week |_ Week number |_ Time point of day change |_ State of parameter activation |_ Special supplier information |_ Duration since last comulation [hour(s)..year(s)] |_ Operation time battery [hour(s)..year(s)] |_ Date and time of battery change |_ Energy MWh |_ Energy GJ |_ Volume |_ Mass |_ Volume 0,1 feet^3 |_ Volume 0,1 american gallon |_ Volume 1 american gallon |_ Volume flow 0,001 american gallon/min |_ Volume flow 1 american gallon/min |_ Volume flow 1 american gallon/h |_ Power MW |_ Power GJ/h |_ Flow Temperature |_ Return Temperature |_ Temperature Difference |_ External Temperature |_ Cold/Warm Temperature Limit °F |_ Cold/Worm Temperature Limit °C |_ Cumul. count max power INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus – Concentrator - Datalogger Document code: MN67054M_ENG Revision 1.021 Pagina 19 di 34 Industrial Electronic Devices |_ per second |_ per minute |_ per hour |_ per day |_ per week |_ per month |_ per year |_ per revolution/measurement |_ increment per input pulse on input channel |_ increment per output pulse on output channel |_ per liter |_ per m^3 |_ per kg |_ per K (Kelvin) |_ per kWh |_ per GJ |_ per kW |_ per (K*l)(Kelvin*liter) |_ per V (Volt) |_ per A (Ampere) |_ multiplied by sek |_ multiplied by sek/V |_ multiplied by sek/A |_ start date(/time) of |_ VIF contains uncorrected unit instead of corrected unit |_ Accumulation only if positive contributions |_ Accumulation of abs value only if negative contributions |_ upper/lower limit value |_ # of exceeds of lower/upper limit |_ Date(/time) of begin/end of first/last lower/upper limit exceed ADFweb.com Srl – IT31010 – Mareno – Treviso |_ Duration of limit exceed |_ Duration of first/last |_ Date(/time) of first/last begin/end |_ Multiplicative currection factor |_ Additive correction constant * unit of VIF (offset) |_ Moltiplicative correction factor: 10^3 |_ future value |_ next VIFE's and data of this block are manufacturer specific |_ None |_ Too many DIFE's |_ Storage number not implemented |_ Unit number not implemented |_ Tariff number not implemented |_ Function not implemented |_ Data class not implemented |_ Data size not implemented |_ Too many VIFE's |_ Illegal VIF-Group |_ Illegal VIF-Exponent |_ VIF/DIF mismatch |_ Unimplemented action |_ No data available (undefined value) |_ Data overflow |_ Data underflow |_ Data error |_ Premature end of record INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus – Concentrator - Datalogger Document code: MN67054M_ENG Revision 1.021 Pagina 20 di 34 Industrial Electronic Devices CSV FILE When the file is downloaded and opened in a table there are two codes that identify what the number is referred to. At right side you can find an example of file. A: In this field you find the “Title” that you have defined in the compositor; B: This is the date and time of the last scan; C: If in the compositor you have select “M-Bus Node Data” here you can find the “User”; D: If in the compositor you have select “M-Bus Node Data” here you can find the “Scale”; E: If in the compositor you have select “M-Bus Node Data” here you can find the “Floor”; F: If in the compositor you have select “M-Bus Node Data” here you can find the “Flat”; G: This is the Primary Address of the M-Bus Slave Device; H: This is the number of variables defined in the compositor; I: This is the value read of the variable; J: This is the “First Code”. It identify the type of data. For decoded it see “First Code” subsection; K: This is the “Second Code”. Is in addition and complete the information given by the “First Code”. For decoded it see “Second Code” subsection; L: If in the compositor you have select “M-Bus Node Description” here you can find the “Description”. ADFweb.com Srl – IT31010 – Mareno – Treviso Figure 5: Example of CSV file INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus – Concentrator - Datalogger Document code: MN67054M_ENG Revision 1.021 Pagina 21 di 34 Industrial Electronic Devices FIRST CODE: 31: 32: Mass kg (*103) Mass kg (*104) 33: 34: 35: 36: On On On On 37: 38: 39: 40: Operating Operating Operating Operating 0: Null 1: 2: 3: 4: 5: 6: 7: 8: Energy Energy Energy Energy Energy Energy Energy Energy [Wh] [Wh] [Wh] [Wh] [Wh] [Wh] [Wh] [Wh] 9: 10: 11: 12: 13: 14: 15: 16: Energy Energy Energy Energy Energy Energy Energy Energy [J] [J] [J] [J] [J] [J] [J] [J] (*100) (*101) (*102) (*103) (*104) (*105) (*106) (*107) 41: 42: 43: 44: 45: 46: 47: 48: Power Power Power Power Power Power Power Power W W W W W W W W 17: 18: 19: 20: 21: 22: 23: 24: Volume Volume Volume Volume Volume Volume Volume Volume m3 m3 m3 m3 m3 m3 m3 m3 (*10-6) (*10-5) (*10-4) (*10-3) (*10-2) (*10-1) (*100) (*101) 49: 50: 51: 52: 53: 54: 55: Power Power Power Power Power Power Power J/h J/h J/h J/h J/h J/h J/h 56: Power J/h (*107) 57: 58: 59: 60: 61: Volume Volume Volume Volume Volume 25: 26: 27: 28: 29: 30: Mass Mass Mass Mass Mass Mass kg kg kg kg kg kg (*10-3) (*10-2) (*10-1) (*100) (*101) (*102) (*103) (*104) -3 (*10 ) (*10-2) (*10-1) (*100) (*101) (*102) ADFweb.com Srl – IT31010 – Mareno – Treviso Time: Time: Time: Time: Seconds Minutes Hours Days Time: Time: Time: Time: Seconds Minutes Hours Days (*10-3) (*10-2) (*10-1) (*100) (*101) (*102) (*103) (*104) (*100) (*101) (*102) (*103) (*104) (*105) (*106) Flow Flow Flow Flow Flow m3/h m3/h m3/h m3/h m3/h (*10-6) (*10-5) (*10-4) (*10-3) (*10-2) INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus – Concentrator - Datalogger Document code: MN67054M_ENG Revision 1.021 Pagina 22 di 34 Industrial Electronic Devices 62: 63: 64: Volume Flow m3/h (*10-1) Volume Flow m3/h (*100) Volume Flow m3/h (*101) 3 -7 65: 66: 67: 68: 69: 70: 71: 72: Volume Volume Volume Volume Volume Volume Volume Volume Flow Flow Flow Flow Flow Flow Flow Flow ext. m /min (*10 ) m3/min (*10-6) m3/min (*10-5) m3/min (*10-4) m3/min (*10-3) m3/min (*10-2) m3/min (*101) m3/min (*100) 73: 74: 75: 76: 77: 78: 79: 80: Volume Volume Volume Volume Volume Volume Volume Volume Flow Flow Flow Flow Flow Flow Flow Flow ext. m3/s (*10-9) m3/s (*10-8) m3/s (*10-7) m3/s (*10-6) m3/s (*10-5) m3/s (*10-4) m3/s (*10-3) m3/s (*10-2) 81: 82: 83: 84: 85: 86: 87: Mass Mass Mass Mass Mass Mass Mass 88: Mass Flow kg/h (*104) 89: 90: 91: 92: Flow Flow Flow Flow Flow Flow Flow Flow Flow Flow Flow kg/h kg/h kg/h kg/h kg/h kg/h kg/h (*10-3) (*10-2) (*10-1) (*100) (*101) (*102) (*103) Temperature Temperature Temperature Temperature [°C] [°C] [°C] [°C] (*10-3) (*10-2) (*10-1) (*100) ADFweb.com Srl – IT31010 – Mareno – Treviso 93: 94: Return Temperature [°C] (*10-3) Return Temperature [°C] (*10-2) 95: 96: Return Temperature [°C] (*10-1) Return Temperature [°C] (*100) 97: 98: 99: 100: Temperature Temperature Temperature Temperature 101: 102: 103: 104: External External External External Temperature Temperature Temperature Temperature 105: 106: 107: 108: Pressure Pressure Pressure Pressure [bar] [bar] [bar] [bar] 109: 110: Time Point: Date Time Point: Time & Date 111: 112: 113: 114: Averaging Averaging Averaging Averaging 115: Actually Duration: Seconds 116: 117: 118: Actually Duration: Minutes Actually Duration: Hours Actually Duration: Days 119: 120: Credit of 10-3 of the nominal local legal currency units Credit of 10-2 of the nominal local legal currency units Difference Difference Difference Difference [K] [K] [K] [K] [°C] [°C] [°C] [°C] (*10-3) (*10-2) (*10-1) (*100) (*10-3) (*10-2) (*10-1) (*100) (*10-3) (*10-2) (*10-1) (*100) Duration: Duration: Duration: Duration: Seconds Minutes Hours Days INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus – Concentrator - Datalogger Document code: MN67054M_ENG Revision 1.021 Pagina 23 di 34 Industrial Electronic Devices 121: 122: Credit of 10-1 of the nominal local legal currency units Credit of 100 of the nominal local legal currency units 154: 155: Storage interval [hours] Storage interval [days] 123: Debit of 10-3 of the nominal local legal currency units 156: 157. Storage interval month(s) Storage interval year(s) 124: 125: 126: Debit of 10-2 of the nominal local legal currency units Debit of 10-1 of the nominal local legal currency units Debit of 100 of the nominal local legal currency units 127: 128: 129: 130: 131: 132: 133: 134: 135: 136: 137: 138: 139: 140: 141. 142. 143: 144: 145. 146. 147: 148: Access Number (transmission count) Medium (as in fixed header) Manufacturer (as in fixed header) Parameter set identification Model/Version Hardware version # Firmware version # Software version # Customer Location Customer Access Code User Access Code Operator Access Code System Operator Access Code Developer Password Error flags (binary) Error mask Digital Output (binary) Digital Input (binary) Baudrate [Baud] response delay time [bittimes] Retry 158: 159: 160: 161: Duration Duration Duration Duration 162: Start (date/time) of tariff 163: 164: 165: Duration of tariff [minutes] Duration of tariff [hours] Duration of tariff [days] 166: 167: 168: 169: Period Period Period Period 170: 171: 172: Period of tariff months(s) Period of tariff year(s) dimensionless/ no VIF 173: 174: 175: 176: 177: 10-9 Volts 10-8 Volts 10-7 Volts 10-6 Volts 10-5 Volts 149: 150: 151. 152: 153: First storage # for cyclic storage Last storage # for cyclic storage Size of storage block Storage interval [seconds] Storage interval [minutes] 178: 179: 180: 181: 10-4 Volts 10-3 Volts 10-2 Volts 10-1 Volts ADFweb.com Srl – IT31010 – Mareno – Treviso since since since since of of of of tariff tariff tariff tariff last last last last readout[seconds] readout[minutes] readout[hours] readout[days] [seconds] [minutes] [hours] [days] INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus – Concentrator - Datalogger Document code: MN67054M_ENG Revision 1.021 Pagina 24 di 34 Industrial Electronic Devices 182: 183: 184: 185: 186: 187: 188: 100 Volts 101 Volts 102 Volts 103 Volts 104 Volts 105 Volts 106 Volts 215: 216: Duration since last comulation [months] Duration since last comulation [years] 217: 218: 219: 220: Operation Operation Operation Operation 189: 190: 191: 192: 193: 194: 195: 196: 197: 198: 199: 200: 201: 202: 203: 204: 10-12 Ampere 10-11 Ampere 10-10 Ampere 10-9 Ampere 10-8 Ampere 10-7 Ampere 10-6 Ampere 10-5 Ampere 10-4 Ampere 10-3 Ampere 10-2 Ampere 10-1 Ampere 100 Ampere 101 Ampere 102 Ampere 103 Ampere 221: Date and time of battery change 222: 223: Energy [MWh] (*10-1) Energy [MWh] (*100) 224: 225: Energy [GJ] (*10-1) Energy [GJ] (*100) 226: 227: Volume [m3] (*102) Volume [m3] (*103) 228: 229: Mass [t] (*102) Mass [t] (*103) 205: 206: 207: 208: 209: 210: 211: Reset counter Comulation counter Control signal Day of week Week number Time point of day change State of parameter activation 230: 231: 232: 233: 234: 235: Volume Volume Volume Volume Volume Volume 236: 237: Power [MW] (*10-1) Power [MW] (*100) 238: 239: Power [GJ/h] (*10-1) Power [GJ/h] (*100) 240: 241: Flow Temperature [°F] (*10-3) Flow Temperature [°F] (*10-2) 212: 213: 214: Special supplier information Duration since last comulation [hours] Duration since last comulation [days] ADFweb.com Srl – IT31010 – Mareno – Treviso time time time time battery battery battery battery [hours] [days] [months] [years] 0,1 feet^3 0,1 american gallon 1 american gallon flow 0,001 american gallon/min flow 1 american gallon/min flow 1 american gallon/h INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus – Concentrator - Datalogger Document code: MN67054M_ENG Revision 1.021 Pagina 25 di 34 Industrial Electronic Devices 242: 243: Flow Temperature [°F] (*10-1) Flow Temperature [°F] (*100) 244: 245: 246: 247: Return Return Return Return 248: 249: Temperature Difference [°F] (*10-3) Temperature Difference [°F] (*10-2) 250: 251: Temperature Difference [°F] (*10-1) Temperature Difference [°F] (*100) 252: 253: 254: 255: External External External External 256: 257: 258: 259: Cold/Warm Cold/Warm Cold/Warm Cold/Warm Temperature Temperature Temperature Temperature Limit Limit Limit Limit [°F] [°F] [°F] [°F] (*10-3) (*10-2) (*10-1) (*100) 260: 261: 262: 263: Cold/Worm Cold/Worm Cold/Worm Cold/Worm Temperature Temperature Temperature Temperature Limit Limit Limit Limit [°C] [°C] [°C] [°C] (*10-3) (*10-2) (*10-1) (*100) 264: 265: 266: 267: 268: 269: Cumul. Cumul. Cumul. Cumul. Cumul. Cumul. Temperature Temperature Temperature Temperature [°F] [°F] [°F] [°F] Temperature Temperature Temperature Temperature count count count count count count max max max max max max (*10-3) (*10-2) (*10-1) (*100) [°F] [°F] [°F] [°F] power power power power power power 270: 271: Cumul. count max power [W] (*103) Cumul. count max power [W] (*104) 272÷299: Empty (*10-3) (*10-2) (*10-1) (*100) [W] [W] [W] [W] [W] [W] (*10-3) (*10-2) (*10-1) (*100) (*101) (*102) ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus – Concentrator - Datalogger Document code: MN67054M_ENG Revision 1.021 Pagina 26 di 34 Industrial Electronic Devices SECOND CODE: 0: Null 300: 301: 302: 303: 304: 305: 306: 307: 308: 309: 310: 311: 312: 313: 314: 315: 316: 317: 318: 319: 320: 321: 322: 323: 324: 325: 326: 327: 328: 329: 330: 331: 332: per second per minute per hour per day per week per month per year per revolution/measurement increment per input pulse on input channel 0 increment per input pulse on input channel 1 increment per output pulse on output channel 0 increment per output pulse on output channel 1 per liter per m3 per kg per K (Kelvin) per kWh per GJ per kW per (K*l)(Kelvin*liter) per V (Volt) per A (Ampere) multiplied by sek multiplied by sek/V multiplied by sek/A start date(/time) of VIF contains uncorrected unit instead of corrected unit Accumulation only if positive contributions Accumulation of abs value only if negative contributions upper limit value lower limit value # of exceeds of upper limit # of exceeds of lower limit ADFweb.com Srl – IT31010 – Mareno – Treviso 333: 334: 335: 336: 337: 338: 339: 340: Date(/time) Date(/time) Date(/time) Date(/time) Date(/time) Date(/time) Date(/time) Date(/time) of of of of of of of of begin of first lower limit exceed end of first lower limit exceed begin of last lower limit exceed end of last lower limit exceed begin of first upper limit exceed end of first upper limit exceed begin of last upper limit exceed end of last upper limit exceed 341: 342: 343: 344: 345: 346: 347: 348: 349: 350: 351: 352: 353: 354: 355: 356: Duration Duration Duration Duration Duration Duration Duration Duration Duration Duration Duration Duration Duration Duration Duration Duration of of of of of of of of of of of of of of of of limit limit limit limit limit limit limit limit limit limit limit limit limit limit limit limit 357: 358: 359: 360: 361: 362: 363: 364: Duration Duration Duration Duration Duration Duration Duration Duration of of of of of of of of first/last first/last first/last first/last first/last first/last first/last first/last 365: 366: Date(/time) of first/last begin/end Date(/time) of first/last begin/end exceed exceed exceed exceed exceed exceed exceed exceed exceed exceed exceed exceed exceed exceed exceed exceed INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus – Concentrator - Datalogger Document code: MN67054M_ENG Revision 1.021 Pagina 27 di 34 Industrial Electronic Devices 367: 368: Date(/time) of first/last begin/end Date(/time) of first/last begin/end 369: 370: 371: 372: 373: 374: 375: 376: 377: 378: 379: 380: Multiplicative correction factor (*10-6) Multiplicative correction factor (*10-5) Multiplicative correction factor (*10-4) Multiplicative correction factor (*10-3) Multiplicative correction factor (*10-2) Multiplicative correction factor (*10-1) Multiplicative correction factor (*100) Multiplicative correction factor (*101) Additive correction constant * unit of VIF Additive correction constant * unit of VIF Additive correction constant * unit of VIF Additive correction constant * unit of VIF 381: 382: 383: Multiplicative correction factor: 103 future value next VIFE's and data of this block are manufacturer specific ADFweb.com Srl – IT31010 – Mareno – Treviso (offset) (offset) (offset) (offset) 384: 385: 386: 387: 388: 389: 390: 391: 392: 393: 394: 395: 396: 397: 398: 399: 400: 401: None Too many DIFE's Storage number not implemented Unit number not implemented Tariff number not implemented Function not implemented Data class not implemented Data size not implemented Too many VIFE's Illegal VIF-Group Illegal VIF-Exponent VIF/DIF mismatch Unimplemented action No data available (undefined value) Data overflow Data underflow Data error Premature end of record INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus – Concentrator - Datalogger Document code: MN67054M_ENG Revision 1.021 Pagina 28 di 34 Industrial Electronic Devices SOFTWARE & COMMANDS: If you want to use our free software for making the download and do other operations you can www.adfweb.com/download/filefold/MBus_Concentrator_EU.zip. The functioning of this software is described in this manual: www.adfweb.com/download/filefold/MBus_Concentrator_Manual.pdf download this software: If you don’t want to use our free software for making the download operations you have to use these commands: “Password: XXXXXXXXXX”: This must be the first command that you send to the device. Instead of XXXXXXXXXX you have to insert your password. The default password is 0123456789. If the password is correct this message appears: “Password accepted; insert the next command.”. Otherwise: “Password wrong. Please try again.” If you edit for three times the wrong password you have to wait 10 minutes before retype it. The minimum characters for a password is 0 and the maximum is 10. Can be accepted numbers and digits. After that the other commands are: “Read Data Time”: for read the clock data and time “Data read: XXXX/YY/ZZ HH:MM:SS” “Write Data Time: XXXX/YY/ZZ HH:MM:SS”: Instead of XXXX insert the year; YY insert the month; ZZ insert the day; HH insert the hour; MM insert the minutes; SS: insert the seconds. If the string is correct the message “New data: XXXX/YY/ZZ HH:MM:SS” appears. Otherwise: “Wrong data. Please try again”. “Set New Password: XXXXXXXXXX”: In order to change the password you have to send this command. Instead of XXXXXXXXXX insert the new password. If the string is correct the message “New password accepted: XXXXXXXXXX” appears. If the password is more long than 10 characters the message “Password too long.” appears. “Download Last Data”: It is used for download the last .CSV file saved. If no .CSV file is saved, the message “No scan has been performed.” appears. “New Scan”: It is used for doing a immediately scan. It returns a “OK” if it is able to doing another scan. Otherwise if another scan is already in execution the message “The device is already doing a scan.” appears. “DownloadListOfReadings”: It is used for download the list of 12 stored readings where is specified the data/time of the reading. “DownloadStore: xx”: It is used for download the selected stored log. Instead xx, insert a value of the follow: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12. “Exit”: It is used for close the communication and make the Logout from the Password. It returns a “Done”. Any other command different from the ones described above returns a “Unknown Command. Redigit it.”. ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus – Concentrator - Datalogger Document code: MN67054M_ENG Revision 1.021 Pagina 29 di 34 Industrial Electronic Devices UPDATE DEVICE: Section “Update Firmware” (Fig. 6): In order to load the parameters or update the firmware in the device, follow these instructions: Turn off the Device; Connect the Null Modem Cable form your PC to the Gateway; Insert the Boot Jumper (For more info see Fig. 1); Select the COM port and press the “Connect” button; Turn on the device; Check the BOOT Led. It must blink quickly (For more info see Fig. 1); Press the “Next” button; Select which operations you want to do. You can select only “Firmware”, only “Project” or both of them; Press the “Execute update firmware” button to start the upload; When all the operations are “OK” turn off the device; Disconnect the Boot jumper; Disconnect the RS232 Cable; Turn on the device. At this point the configuration/firmware on the device is correctly update. Note: When you install a new version of the software it is better if the first time you do the update of the Firmware in the HD67054M-xxx device. Warning: If the Fig. 7 appears when you try to do the Update before require assistance try these points: Check if the serial COM port selected is the correct one; Check if the serial is connected between the PC and the device; Try to repeat the operations for the updating; If you are using a dongle try with a native COM port or change the dongle; Try with another PC; Try to restart the PC. Figure 7: “Protection” window ADFweb.com Srl – IT31010 – Mareno – Treviso Figure 6: “Update Device” windows INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus – Concentrator - Datalogger Document code: MN67054M_ENG Revision 1.021 Pagina 30 di 34 Industrial Electronic Devices CHARACTERISTICS OF THE CABLE: RS232: The connection from RS232 socket to a serial port (example one from a personal computer) must be made with a Null Modem cable (a serial cable where the pins 2 and 3 are crossed). It is recommended that the RS232C Cable not exceed 15 meters. Figure 8: Null modem cabling In case of using a “Dial-Up Modem” or “ISDN Modem” the cable to use is a cable with all lines that are managed by the board. M-BUS: A two wire standard telephone cable (JYStY N*2*0.8 mm) is used as the transmission medium for the M-Bus. The maximum distance between a slave and the repeater is 350m; this length corresponds to a cable resistance of up 29Ω. This distance applies for the standard configuration having Baud rates between 300 and 9600 Baud, and a maximum of 250 slaves. The maximum distance can be increased by limiting the Baud rate and using fewer slaves, but the bus voltage in the space state must at no point in a segment fall below 12V, because of the remote powering of the slaves. In the standard configuration the total cable length should not exceed 1000m, in order to meet the requirement of a maximum cable capacitance of 180nF. (Taken from M-Bus specifics) ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus – Concentrator - Datalogger Document code: MN67054M_ENG Revision 1.021 Pagina 31 di 34 Industrial Electronic Devices MECHANICAL DIMENSIONS: Figure 9: Mechanical dimensions scheme for HD67054M-20, HD67054M-40, HD67054M-80 Figure 10: Mechanical dimensions scheme for HD67054M-160 Figure 11: Mechanical dimensions scheme for HD67054M-250 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus – Concentrator - Datalogger Document code: MN67054M_ENG Revision 1.021 Pagina 32 di 34 Industrial Electronic Devices ORDER CODES: Order Code: HD67054M-20 - M-Bus - Concentrator - Datalogger (up to 40 slaves connected to M-Bus) Order Code: HD67054M-40 - M-Bus - Concentrator - Datalogger (up to 40 slaves connected to M-Bus) Order Code: HD67054M-80 - M-Bus - Concentrator - Datalogger (up to 80 slaves connected to M-Bus) Order Code: HD67054M-160 - M-Bus - Concentrator - Datalogger (up to 160 slaves connected to M-Bus) Order Code: HD67054M-250 - M-Bus - Concentrator - Datalogger (up to 250 slaves connected to M-Bus) Order Code: AC34107 - Null Modem Cable Fem/Fem DSub 9 Pin 1,5 m Order Code: AC34114 - Null Modem Cable Fem/Fem DSub 9 Pin 5 m ACCESSORIES: ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus – Concentrator - Datalogger Document code: MN67054M_ENG Revision 1.021 Pagina 33 di 34 Industrial Electronic Devices DISCLAIMER All technical content within this document can be modified without notice. The content of the document content is a recurring audit. For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal conditions repairs are charged to the user. ADFweb.com S.r.l. will not be liable for accidental loss of use or inability to use this product, such as loss of business income. ADFweb.com S.r.l. shall not be liable for consequences of improper use. OTHER REGULATIONS AND STANDARDS WEEE INFORMATION Disposal of old electrical and electronic equipment (as in the European Union and other European countries with separate collection systems). This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish. Instead, it should be taken to an applicable collection point for the recycling of electrical and electronic equipment. If the product is disposed correctly, you will help prevent potential negative environmental factors and human health, which could otherwise be caused by inappropriate disposal. The recycling of materials will help to conserve natural resources. For more information about recycling this product, please contact your local city office, your household waste disposal service or the shop where you purchased the product. RESTRICTION OF HAZARDOUS SUBSTANCES DIRECTIVE The device respects the 2002/95/EC Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment (commonly referred to as Restriction of Hazardous Substances Directive or RoHS). CE MARKING The product conforms with the essential requirements of the applicable EC directives. ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual M-Bus – Concentrator - Datalogger Document code: MN67054M_ENG Revision 1.021 Pagina 34 di 34 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT: For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com. Otherwise contact us at the address [email protected] RETURN POLICY: If while using your product you have any problem and you wish to exchange or repair it, please do the following: 1) Obtain a Product Return Number (PRN) from our internet support at www.adfweb.com. Together with the request, you need to provide detailed information about the problem. 2) Send the product to the address provided with the PRN, having prepaid the shipping costs (shipment costs billed to us will not be accepted). If the product is within the warranty of twelve months, it will be repaired or exchanged and returned within three weeks. If the product is no longer under warranty, you will receive a repair estimate. PRODUCTS AND RELATED DOCUMENTS: Part Description URL HD67120 Converter Ethernet to RS232/RS485 www.adfweb.com?product=HD67120 HD67119 Converter USB 2.0 to RS485 Isolated www.adfweb.com?product=HD67119 HD67507 Gateway Modbus TCP Server to RTU Master www.adfweb.com?product=HD67507 HD67510 Gateway Modbus TCP Client to RTU Slave www.adfweb.com?product=HD67510 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31
advertisement
Related manuals
advertisement