Acromag IOS-7400 User manual

Add to My manuals
48 Pages

advertisement

Acromag IOS-7400 User manual | Manualzz

IOS-7400

Industrial Computer with 1.6MHz Intel

®

Atom processor

USER’S MANUAL

ACROMAG INCORPORATED Tel: (248) 295-0310

30765 South Wixom Road Fax: (248) 624-9234

P.O. BOX 437 Email: [email protected]

Wixom, MI 48393-7037 U.S.A. Web: http://www.acromag.com

Copyright 2010-2011, Acromag, Inc., Printed in the USA.

Data and specifications are subject to change without notice.

8500-879-D13C019

2

I/O SERVER User’s Manual Industrial PC

__________________________________________________________________

TABLE OF

CONTENTS

The information in this manual may change without notice.

Acromag makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Further, Acromag assumes no responsibility for any errors that may appear in this manual and makes no commitment to update, or keep current, the information contained in this manual. No part of this manual may be copied or reproduced in any form without the prior written consent of Acromag, Inc.

IMPORTANT SAFETY CONSIDERATIONS

You must consider the possible negative effects of power, wiring, component, sensor, or software failure in the design of any type of control or monitoring system. This is very important where property loss or human life is involved. It is important that you perform satisfactory overall system design and it is agreed between you and Acromag, that this is your responsibility.

1.0 General Information

KEY FEATURES

………………………………………...

BOARD CONTROL SOFTWARE

……………………..

SIGNAL INTERFACE PRODUCTS

……………………

2.0 PREPARATION FOR USE

UNPACKING AND INSPECTION

……………………..

BOARD CONFIGURATION

…………………………….

Default Hardware Configuration

……………….

IOS MODULE INSTALLATION

………………………..

FRONT PANEL FIELD I/O CONNECTOR

……………

10/100 Ethernet Connection

…………………….

VGA Video Connection

…………………………..

Serial Connections

……………………………….

USB Ports

…………………………………………..

Audio Jacks

………………………………………..

IOS Modules Field I/O

……………………………

REAR PANEL FIELD CONNECTORS

………………..

CompactFlash

®

……………………………………

Power & LEDs

……………………………………..

OPTIONAL 2.5” DRIVE…………………………………

2.

5” IDE Drive Installation……………………….

NON-ISOLATION CONSIDERATIONS

……………….

3.0 BIOS

MAIN MENU

……………………………………………...

Passwords

…………………………………………

STANDARD CMOS FEATURES

………………………

ADVANCED BIOS FEATURES

………………………..

ADVANCED CHIPSET FEATURES

…………………..

Integrated Peripherals

…………………………………

ONCHIP IDE DEVICE

…………………………………...

ONBOARD DEVICE

…………………………………….

SUPERIO DEVICE

………………………………………

USB DEVICE SETTINGS

……………………………….

POWER MANAGEMENT SETUP

……………………..

PnP/PCI CONFIGURATIONS

………………………….

PC HEALTH STATUS

…………………………………..

FREQUENCY/VOLTAGE CONTROL

…………………

BIOS RECOVERY PROCEDURE

……………………..

9

10

10

11

11

11

12

6

6

6

7

8

8

9

12

12

13

22

23

24

25

25

26

26

27

14

15

16

17

19

20

21

4

5

5

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

I/O SERVER User’s Manual Industrial PC

___________________________________________________________________

3

TABLE OF

4.0 SYSTEM OVERVIEW

I/O Server Internal Ethernet Switch

…………………

I/O Server Power Supply Fuse

……………………….

IDE (PATA) Hard Drive Connections

………………..

MLC vs. SLC Flash

……………………………………..

CARRIER BOARD OVERVIEW

……………………….

PCI Bus Interface

…………………………………

IOS Carrier Board Registers

……………………

IOS Logic Interface

……………………………….

IOS Carrier Board Clock Circuitry

……………..

PCI Interrupts

……………………………………...

IOS Modules Power-On Reset

………………….

IOS Modules Power Supply Fuses

…………….

5.0 ACCESSING THE IOS CARRIER

PCI Configuration Address Space

…………………..

PCI Configurations Transactions

……………………

PCI Configuration Registers

………………………….

MEMORY MAP

…………………………………………..

Carrier Status/Control Register

………………..

IOS Interrupt Pending Register

………………...

Clock Control Register

…………………………..

IOS Module Interrupt Space

…………………….

IOS Module ID Space

…………………………….

IOS Module I/O Space

……………………………

IOS Module Memory Space

……………………..

GENERATING INTERRUPTS

………………………….

6.0 SERVICE AND REPAIR

SERVICE AND REPAIR ASSISTANCE

………………

PRELIMINARY SERVICE PROCEDURE

…………….

WHERE TO GET HELP

…………………………………

7.0 SPECIFICATIONS

PHYSICAL

………………………………………………..

ELECTRICAL

…………………………………………….

ENVIRONMENTAL

……………………………………...

APPENDIX

IOS-7400 BLOCK DIAGRAM

………………………….

IOS-CARRIER FUSE LOCATION DRAWING

……….

SYSTEM I/O PORTS MEMORY MAP

………………...

SYSTEM IRQ ASSIGMENTS

…………………………..

SYSTEM 1MB MEMORY MAP

………………………...

Trademarks are the property of their respective owners.

36

36

37

37

37

37

31

31

31

32

34

36

29

29

30

30

30

30

30

28

28

28

29

29

38

38

38

39

39

42

44

45

46

47

48

CONTENTS

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

4

I/O SERVER User’s Manual Industrial PC

__________________________________________________________________

1.0 GENERAL

INFORMATION

Table 1.1: I/O Server Basic

Models

KEY FEATURES

The I/O Server Industrial computer provides users with a mobile rugged computing option with a wide variety of integrated I/O connections. The

IOS-7400 has a built in 1.6MHz Intel

®

Atom processor with 1GB of DDR2

RAM and features two Ethernet ports, four USB ports, audio, video, and two COM ports.

The I/O Server’s built in carrier card allows for users to select up to four plug-in I/O modules that provide a wide range of industrial input/output including digital, analog inputs, analog outputs, counter-timer modules, and a module with a customer programmable FPGA. All these items are packaged in a small rugged fanless form factor with an extended operating temperature range. Refer to the table below for available I/O

Server models.

MODEL

Front I/O Type

Front I/O Connector

OPERATING

TEMPERATURE

RANGE

IOS-7200

AMD

®

Geode LX800 500MHz

512MB DDR

-30

C to +75

C

IOS-7400

Intel

®

Atom N270 1.6GHz

1GB DDR2

-30

C to +75

C

Both models are available with a -WIN suffix. These versions include an

8GB Industrial CompactFlash

®

with a Windows

®

Embedded Standard image and license.

The I/O Server and IOS modules are suitable for use in Class I, Division 2,

Groups A, B, C, and D hazardous locations or non-hazardous locations only.

The following models are the available IOS modules, which are cULus listed and can only be used in the IOS-7200 & IOS-7400 I/O Server. All

IOS models operate at the full operating temperate of the base I/O Server unit. Refer to the individual manuals for each of the IOS modules for further information.

Models: IOS-220-8, IOS-220-16, IOS-231-8, IOS-231-16, IOS-320, IOS-

330, IOS-341, IOS-EP201, IOS-EP202, IOS-EP203, IOS-EP204, IOS-520,

IOS-521, IOS-560, IOS-560-I, IOS-571, IOS-572, IOS-408, IOS-409, IOS-

440-2, IOS-445, IOS-470, IOS-482, IOS-483, and IOS-484.

Rugged Embedded PC

– The IOS-7400 includes an embedded

1.6GHz Intel

®

Atom processor with 1GB of installed DDR2 RAM. This is a low power fanless design with high-reliability operation that is shock and vibration resistant.

High-density, Interchangeable I/O

– Each I/O server supports up to four separate IOS module to enable mix and match flexibility for a wide variety of field I/O.

Extended Temperature Range

– The IOS-7400 has a wide operating temperature range even with four IOS modules installed under a full system load.

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

I/O SERVER User’s Manual Industrial PC

___________________________________________________________________

5

Standard Peripheral Connection

The I/O Server provides two standard RS232 serial ports, two switched Ethernet ports, four USB, audio, and video ports for peripheral connections.

Windows

® a Windows

Embedded Standard

The IOS-7400-WIN model includes

®

Embedded Standard (based upon Windows image installed on an 8GB Industrial CompactFlash

®

.

®

XP SP3)

Windows Drivers

The IOSSW-DEV-WIN software support package contains low-level driver and Windows 32 Dynamic Link Libraries that are compatible with many programming environments.

Linux Drivers

The IOSSW-API-LNX software support package contains the Linux OS Getting Started Guide and IOS modules Linux device drivers are available from Acromag.

Wide Operating Voltage

The I/O Server has a 9-32V DC input.

External isolated AC/DC power supplies are available from Acromag.

The IOS-7400-WIN model includes an 8GB industrial CompactFlash that contains a licensed Microsoft Windows

®

®

Embedded Standard image.

The image includes many of the standard Windows components and is suitable for the majority of customer applications. This allows users to quickly develop their application in a familiar environment. Device drivers for Acromag IOS modules are sold separate as described in the following section.

Acromag provides a software product (sold separately) to facilitate the development of Windows

®

Embedded Standard applications interfacing with I/O Server Modules installed on Acromag Industrial I/O Server systems. This software (Model IOSSW-DEV-WIN) consists of low-level driver and Windows 32 Dynamic Link Libraries (DLLS) that are compatible with a number of programming environments including Visual C++, Visual

Basic.NET, Borland C++ Builder and others. The DLL functions provide a high-level interface to the IOS carrier and modules eliminating the need to perform low-level reads/writes of registers, and the writing of interrupt handlers.

BOARD CONTROL

SOFTWARE

Windows

®

Embedded

Standard

IOS MODULE Win32 DRIVER

SOFTWARE

IOS MODULE LINUX

SOFTWARE

Acromag provides a software product (sold separately) consisting of

IOS module Linux support software. This software (Model IOSSW-API-

LNX) is composed of Linux libraries designed to support applications accessing I/O Server Modules installed on Acromag Industrial I/O Server systems.

The software is implemented as a library of “C” functions which link with existing user code.

SIGNAL INTERFACE

PRODUCTS

Acromag provides the following interface products for the I/O Server.

Note that all connections to field signals are made through the IOS carrier board which passes them to the individual IOS modules.

Model 5028-438: SCSI-2 50 Pin Shielded Cable. A round 50-pin cable with SCSI-2 plug connectors at both ends for connecting I/O Server to

Model 5028-378 termination panels.

CABLES

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

6

I/O SERVER User’s Manual Industrial PC

__________________________________________________________________

TERMINATION PANEL

Model 5028-378: DIN-rail mountable panel provides 50 screw terminals for universal field I/O termination. Connects to Acromag IOS-7400 via

Refer to Acromag’s website www.acromag.com for more information on compatible products.

SCSI-2 50 pin shielded cable (Model 5028-438)

2.0 PREPARATION

FOR USE

UNPACKING AND

INSPECTION

ENVIRONMENTAL

CONSIDERATIONS

BOARD

CONFIGURATION

Default Hardware

Configuration

Warnings

Upon receipt of this product, inspect the shipping carton for evidence of mishandling during transit. If the shipping carton is badly damaged or water stained, request that the carrier's agent be present when the carton is opened. If the carrier's agent is absent when the carton is opened and the contents of the carton are damaged, keep the carton and packing material for the agent's inspection.

For repairs to a product damaged in shipment, refer to the Acromag

Service Policy to obtain return instructions. It is suggested that salvageable shipping cartons and packing material be saved for future use in the event the product must be shipped.

This board is physically protected with packing material. However, it is recommended that the unit be visually inspected for evidence of mishandling prior to applying power.

Refer to the specifications for loading and power requirements. Be sure that the system power supplies are able to accommodate the power requirements of the system board, plus the installed IOS modules, within the voltage tolerances specified.

The I/O Server is designed to operate in areas with little or no air circulation. However to facilitate conduction cooling of the unit, it must be orientated such that heat fins are on top or the side of the device (in reference to the floor). Orientating the object with the heat fins facing downward may cause the internal temperature to rise above the maximum operating temperature.

Remove power from the system before installing any IOS modules, cables, and/or field wiring.

Upon receipt, customer can use the I/O Server once an appropriate operating system has been installed.

WARNING

– EXPLOSION HAZARD – Do not disconnect equipment unless power has been removed or area the area is known to be nonhazardous.

WARNING

– EXPLOSION HAZARD – Substitution of any components may impair suitability for Class I, Division 2.

WARNING

– EXPLOSION HAZARD – The area must be known to be non-hazardous before servicing/replacing the unit and before installing.

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

I/O SERVER User’s Manual Industrial PC

___________________________________________________________________

7

To install the IOS modules, first remove all power from the device. The

IOS Carrier is not hot swappable. Failure to power down the I/O Server prior to removing the IOS carrier will result in board damage. To remove the IOS Carrier turn the two Captive screws counterclockwise on the front panel until they are free of the enclosure. Then pull the IOS Carrier out from the enclosure. The IOS Carrier slides out on guide rails. Note that some force is required to remove the IOS Carrier, especially if IOS modules are already installed. Refer to the picture below.

Captive Screws (2x)

IOS Carrier

Once the IOS Carrier has been removed install the IOS modules onto the Carrier board. The modules are keyed to avoid incorrect installation.

No further hardware is required to secure the IOS modules. The four slots are marked as A, B, C or D. Note the slot location of each module as this information is necessary to access the IOS module from software. Refer to

Section 4.0 for further information on accessing the IOS modules.

IOS Module Installation

DANGER: The IOS Carrier is

NOT hot swappable. Power must be removed from the device before removing the

IOS Carrier.

Figure 2.1: IOS Carrier

Removal.

To remove the Carrier turn the

2 captive screws to the left until they are detached from the faceplate. Then pull out the IOS carrier.

Figure 2.2a: IOS Module

Installation

To install the IOS Modules firmly press them into any of the four available slots. IOS

Modules are keyed to avoid incorrect installation.

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

8

I/O SERVER User’s Manual Industrial PC

__________________________________________________________________

Figure 2.2b: IOS Module

Installation

To install the IOS Modules firmly press them into any of the four available slots. IOS

Modules are keyed to avoid incorrect installation.

Note: Inserting the IOS Carrier may require considerable force.

Front Panel Field I/O

Connector

10/100 Ethernet

Connection

Figure 2.3: Ethernet Ports

After IOS module installation, slide the IOS Carrier back into the enclosure via the guide rails until the front panel is flush against the faceplate. Note that considerable force is required to push the carrier and the mating connector together. Once the panel is flush, turn the two captive screws clockwise until tight.

The I/O Server front panel has many of the same connections as a standard personal computer. This includes Ethernet, audio, video, USB, and serial ports. Access to these ports is obtained though the Operating

System. The front panel also provides user access to the IOS carrier board which contains the IOS modules as well as the corresponding I/O connections (ports). Information regarding these ports is contained in the following section.

There are two RJ45 10/100 Ethernet ports available on the front of the

I/O Server. These two ports connect to an internal three port switch. The third port of the switch connects to the processor unit. The two external ports can be used independently of the processor. Refer to the specifications settings for further information on the Ethernet port settings.

The two Ethernet ports are shown below.

The pin outs for the Ethernet connector from left to right are numbered one through eight in order. The upper left yellow LED on each port indicates connection speed. A blinking yellow LED indicates a 10Mbps connection while a solid yellow LED indicates a 100Mbps connection. The upper right Green LED is solid when a link is established and blinks as data is transferred.

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

I/O SERVER User’s Manual Industrial PC

___________________________________________________________________

9

Pin Description

Rx+

TX+

NC

NC

1

2

Ethernet RJ45 Connections

Pin

1

3

5

7

Pin Description

Rx-

NC

1

Tx-

NC

2

Pin

2

4

6

8

The I/O Server has one 15 pin DSUB connecter for a standard Video

Graphics Array (VGA) video connection. The resolution of the display is dependent on the model and is provided in the specification section of this manual. This output is intended to be plugged directly into a compatible monitor. Monitors with only Digital Visual Interface (DVI) inputs will require an external VGA to DVI convertor. The pin connections and description for the video connection are shown in the figures and table below.

Table 2.1: Ethernet Port

Connections

1. These pins are shorted internally.

2. These pins are shorted internally.

VGA Video Connection

Figure 2.4: Video (VGA) Port with pin out.

VGA Video Pin Connections

Pin Description Pin Pin Description

Red Out 1 Green Out

Pin

2

Blue Out

Ground

3

5

NC

Ground

4

6

Ground

+5V

1

No Connect

Horizontal Sync

Clock Data Out

7

9

11

13

15

Ground

Ground

DCC Data Out

Vertical Synch

8

10

12

14

The I/O Server has two 9 pin DSUB connectors on the front panel for standard serial connections. Control of these ports is obtained through the operating system via standard Intel addressing. Refer to the Processor

Memory Map & Interrupt Request Assignments located in the Appendix for the specific address and IRQ designations. Address locations and IRQ settings may be altered in the system BIOS. Refer to Section 3.0 for more information on BIOS settings. The pin connections and description for the serial connections are shown in the figures and table below.

Table 2.2: Video Port

Connections

1. This signal has an internal fuse.

Serial Connections

Figure 2.5: Serial Port and pin numbering.

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

10

I/O SERVER User’s Manual Industrial PC

__________________________________________________________________

Table 2.3: Serial Port

Connections

USB Ports

Figure 2.6: USB Port and pin numbering.

Serial Port Pin Connections

Pin Description Pin

DCD

Receive Data

1

2

Transmit Data

DTR

Ground

DSR

3

4

5

6

RTS

CTS

7

8

RI 9

The I/O Server has four USB 2.0 compliant ports. The four ports labeled USB1, USB2, and USB3/4, are all high retention USB ports. These ports require an additional 50% of force to insert and remove the cable connections as compared to the standard USB ports. Each USB port can source up to 500mA of current. USB devices that exceed the maximum current are automatically disabled via the hardware. The pin connections and description for the USB connections are shown in the figures and table below.

High Retention

USB Ports

High Retention

USB Ports

Table 2.4: USB Port

Connections.

1. The 5V has an internal

500mA current limiter.

Audio Jacks

Figure 2.7: Audio Out and

Microphone jacks

USB Port Pin Connections

Pin Description

5V

1

Pin

1

Data- 2

Data+

Ground

3

4

The I/O Server has two 3.5mm audio jacks. There is an 8

Ω stereo audio line out that generally connects to headphones or externally powered speakers. This jack is indicated by the headphone symbol. There is also a high impedance mono microphone input jack. This connector is indicated by the microphone symbol.

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

I/O SERVER User’s Manual Industrial PC

___________________________________________________________________

11

WARNING: - Explosion Hazard

– The headset and microphone connectors are not for use in the Division 2 area. Use of these connections in a

Division 2 area could result in an explosion.

The IOS Carrier board front panel provides four 50 pin SCSI 2 connectors to access the IOS modules’ Field I/O. Each slot on the IOS

Carrier has a corresponding field I/O connector as marked on the front panel A, B, C, and D. These signals are defined by the individual IOS module that is plugged into the corresponding slot. Pin 1 of the IOS module Field I/O corresponds directly to Pin 1 of the SCSI 2 connection pictured below.

PIN 25

PIN 1

IOS Modules Field I/O

Figure 2.8: SCSI

50 pin connector pin out

PIN 26

PIN 50

The back side of the I/O Server provides access to the DC power terminal, CompactFlash

®

, and status LED’s.

Rear Panel Field

Connections

Figure 2.9: Rear Panel with

CompactFlash

®

slot, Status

LED’s and DC Power

Terminal.

To insert a CompactFlash

®

device firmly push a compatible card with its face up into the slot. The CompactFlash

®

has a left side ejector. The ejector requires two depressions to eject a CompactFlash

®

card. Note that

CompactFlash

®

is not hot swappable. Power must be removed from the system prior to inserting or removing a card.

The top LED when green indicates that power has been applied to the terminal and the internal DC/DC convertor is functioning. When the bottom

LED is yellow this indicates hard drive activity on either the CompactFlash

® or the optional 2.5” drive.

CompactFlash

®

WARNING: CompactFlash

® cards are not hot swappable.

Power must be removed from the I/O Server prior to inserting or removing a CompactFlash

® card.

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

12

I/O SERVER User’s Manual Industrial PC

__________________________________________________________________

Power & LEDs

The 9-32V DC input power connector is a 5.08mm 3 pin terminal block. The terminal screws into the rear panel to a mating connector to

The power input has am internal 10A fuse and internal polarity protection.

WARNING: Double check the power supply wiring connections prior to powering up the unit.

Optional 2.5” Drive

The 2.5” IDE drive must be set as a SLAVE.

2.5” IDE Drive Installation

Figure 2.10: Bottom Plate with Hard drive attached.

provide a rugged connection. The three pins provided are DC-, Earth

Ground, and DC+. Each pin is labeled on the back panel. Users should connect the positive polarity of the DC 9-32V input to the DC+ connection.

The return (or negative) of the DC supply is connected to the port DC-.

The Earth Ground pin is isolated from internal power connections and is connected to the enclosure. User should connect this terminal to an external Earth Ground connection or DC-. Note that the I/O Server may draw up to 7A of current which mandates use or 22 gauge (non-bundled) wire or larger.

The DC input has an internal 10A fuse and reverse polarity protection.

However if these stopgap measures are required, the I/O Server may require factory repair. Acromag recommends an external fuse and/or current limiting power supply for additional protection.

The I/O Server includes an internal

2.5” IDE connection for an additional (or primary) hard drive. This drive MUST BE SET AS A SLAVE even if it is the only drive present. The CompactFlash

®

slot is hardwired as the IDE master. Refer to Section 4.0 the System Overview for more information.

The 2.5” drive (not sold by Acromag) should have shock and vibration and temperature specifications equal to the I/O Server. If there are any discrepancies between these specifications, then the less stringent specification holds. As such Acromag recommends use of a Solid State

Drive. Refer to Section 4.0 for a discussion on the various types of flash drives available. Instructions for installing the optional flash drive are below.

To install the optional flash drive, first remove power and all cables.

Then remove the IOS Carrier as outlined in the IOS Module Installation

Section. Once the IOS Carrier is removed, set it aside and turn the unit so that the bottom is facing up. Then remove the 6x 4-40 Flathead screws on the bottom using a Philips screwdriver.

Once the bottom face plate is removed, screw the hard drive using the four 3mm Philips flat head screws provided by Acromag to the inside of the bottom face plate. Note that the IDE connector must be facing the close edge of the panel. Refer to picture below.

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

I/O SERVER User’s Manual Industrial PC

___________________________________________________________________

13

Then replace the bottom panel with the hard drive attached by sliding it in to the IDE connector. Then replace the six Philips flat head screws on the bottom.

Once the bottom has been replaced and secured, install the IOS Carrier and reattach any cables and power to complete installation.

The I/O Server is non-isolated, since there is electrical continuity between the logic and field I/O grounds. As such, the field I/O connections are not isolated from the system. Care should be taken in designing installations without isolation to avoid noise pickup and ground loops caused by multiple ground connections. Note that some IOS modules such as the IOS-440 and IOS-445 do provide Field I/O isolation from the system. Refer to the individual IOS modules instruction manual for further information.

Figure 2.11: Replacing the bottom panel by sliding in the hard drive.

Non-Isolation

Considerations

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

14

I/O SERVER User’s Manual Industrial PC

__________________________________________________________________

3.0 BIOS

This Section provides the information regarding the AwardBIOS 6.0 and

BIOS SETTINGS SHOULD

ONLY BE MODIFIED BY

ADVANCED USERS.

Main Menu

the available user options on the IOS-7400 models. The IOS-7400 ships with optimum BIOS settings and they should only be modified by an advanced technical user.

To access the system BIOS settings, press the [DEL] button immediately after power-on or reset. The sections below describe the various settings in the BIOS. The system BIOS contains some features that are not available in the I/O Server. Options that are Unused are indicated via a red.

This is the main menu that will appear on the screen when entering the system BIOS. Use the arrow keys to navigate the screen and press

[ENTER] to select the sub-menu or next action. Use the [ESC] key to return to the previous menu. Help information is available for each item in the right pane of the window. Remember to save any changes via the

[F10] key or the option in the main menu.

Standard CMOS Features

This menu includes date, time, and hard drive identifications.

Advanced BIOS Features

This menu includes Boot priority and options.

Advanced Chipset Features

This menu includes all chipset configuration options. Do not modify

these settings.

Integrated Peripherals

This menu includes IDE and USB settings.

Power Management Setup

This menu includes all power management settings.

PnP/PCI Configurations

This menu includes PCI device configuration settings. Do not modify

these settings.

PC Health Status

This page includes the system voltage and temperature monitoring information.

Frequency/Voltage Control

This menu contains CPU host clock control.

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

I/O SERVER User’s Manual Industrial PC

___________________________________________________________________

15

Load Optimized Defaults

This selection loads default BIOS values. Note that this option should only be selected if the IOS-7400 no longer functions due to user changes to the BIOS.

Set Password

This menu allows you to establish, change or disable passwords.

Creating a Password

1. Choose the Set Password option from the Main Menu and press

[ENTER].

2. When you see Enter Password, enter the desired password and press [ENTER].

3. At the Confirm Password prompt, retype the desired password, then press [ENTER].

Changing a Password

1. Choose the Set Password option from the main menu and press

[ENTER].

2. When you see Enter Password, enter the existing password and press [ENTER].

3. You will see the Confirm Password prompt, type it in again, and press [ENTER].

4. Select Set Password again, and at the Enter Password prompt, enter the new password and press [ENTER].

5. At the Confirm Password prompt, retype the new password, and press [ENTER].

Disabling a Password

1. Choose the Set Password option from the main menu and press

[ENTER].

2. When you see the Enter Password prompt, enter the existing password and press [ENTER].

3. You will see Confirm Password, type it in again, and press

[ENTER].

4. Select Set Password again, and at the Enter Password prompt,

DO NOT enter anything - just press [ENTER].

5. At the Confirm Password prompt, again, DO NOT type in anything - just press [ENTER].

Save & Exit Setup

This selection will save BIOS settings and exit the setup screen.

Exit Without Saving

This selection ignores all user changes and exits the setup screen.

Passwords

WARING: Once a BIOS password is set the I/O Server will only boot when the password is entered. If the password is lost of forgotten, there is no recovery and the system will be unusable.

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

16

I/O SERVER User’s Manual Industrial PC

__________________________________________________________________

Standard CMOS Features

This is the Standard CMOS features sub-menu. Users can modify the system date and time here.

Use the Halt on Menu to disable keyboard or video errors on power-up.

Date

The date format is <weekday>, <month>, <day>, <year>. Enter the month using numbers 1-12 (January through December), the day 1-31, and the year 1999-2098. The BIOS will automatically select the correct weekday.

Time

The system time format is <hours>:<minutes>:<seconds>, based on the 24-hour time. Enter the hours (0-23), minutes (0-59), and seconds

(0-59).

IDE Channel 0/1 Master/Slave

These are the IDE drives present in your system. If a CompactFlash

® card is installed in your system it will display as IDE channel 0 Master.

If the 2.5” optional hard drive is installed it will be the IDE Channel 0

Slave. IDE Channel 1 is not used in the IOS-7400. Press "Enter" for automatic device detection.

Drive A [None]

There is no floppy drive in the IOS-7400. This will always display none.

Video [EGA/VGA]

Select video type. Note that the IOS-7400 only supports VGA monitors.

Halt on

This item determines whether the I/O server boot sequence will stop if an error is detected during power up.

 No Errors: The system boot process will not stop for any error

 All Errors: Whenever the BIOS detects a non-fatal error the system boot process will be stopped.

 All, But Keyboard: The system boot process will stop for all but keyboard errors. (Default value)

 All, But Diskette: The I/O Server does not have a floppy drive so this selection will act the same as all errors.

 All, But Disk/Key: The I/O Server does not have a floppy drive so this selection will act the same as All, But Keyboard.

Base/Extended/Total Memory

Displays system memory information.

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

I/O SERVER User’s Manual Industrial PC

___________________________________________________________________

17

The advanced BIOS Features sub-menu allows changes to the Boot priority between the CompactFlash

®

, optional 2.5” drive, and any attached bootable USB devices.

Advanced BIOS Features

Blank Boot [Disabled]

This item allows the user to enable/disable BIOS reporting at powerup.

POST Beep [Disabled]

This Post beep feature is not available on the I/O Server and will never sound regardless of this setting.

CPU Feature

This menu includes advanced CPU options. Do not modify these

settings.

Hard Disk Boot Priority

This item allows the user to select the boot sequence between the

CompactFlash

® and the optional 2.5” drive. Note that if both drives are bootable, you must set the priority here.

USB Boot Priority

This item allows the user to select the boot sequence for any attached bootable USB devices.

Virus Warning[Disabled]

This item is not installed and should be disabled.

CPU L3 Cache/ Hyper-Threading Technology [Enabled]

Do not modify this setting.

Quick Power On Self Test [Enabled]

This field speeds up the Power-On Self Test (POST) routine by skipping redundant testing.

If more then one bootable

Hard Disk or USB drive is connected to the system, use these options to set boot priority between the devices.

The CompactFlash

®

is considered a Hard Disk and is by default the first boot

device.

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

18

I/O SERVER User’s Manual Industrial PC

__________________________________________________________________

To change the boot device select the desired device as the first boot device.

First/Second/Third Boot Device

Hard Disk: Sets boot priority to hard disks.

CDROM: This option is not installed on the I/O Server.

USB devices: Sets boot priority for USB devices that emulate hard drives such as Flash drives or external hard drives.

USB-FDD: Sets boot priority for USB Floppy drives.

USB-ZIP: Sets boot priority for USB Zip drives.

USB-CDROM: Sets boot priority for USB-DVD/CDROM.

LAN Sets boot priority to the local area network. (Network Boot)

Boot Up NumLock Status [On]

This item allows the user to activate the Number Lock key during the boot process.

Gate A20 Option [Fast]

Do not modify this setting.

Typematic Rate Setting [Disabled]

This is a keyboard control item. When enabled it automatically repeats keystrokes when a key is held down based upon the following settings. o Typematic Rate (Chars/Sec)

This controls the speed at which the system registers auto repeated keystrokes. The eight settings are: 6, 8, 10, 12, 15,

20, 24 and 30. o Typematic Delay (msec)

This item sets the key press delay time before auto repeat begins. The four delay rate options are: 250, 500, 750 and

1000 milliseconds.

Security Option [Setup]

If a password is enabled, then the setup selection will require password to change BIOS settings. The system selection requires the correct password prior to booting.

APIC Mode/ MPS Version Control for OS

These items are not used on the IOS-7400 and the settings have no effect on system operation.

OS Select For DRAM > 64 MB [Non-OS2]

Only change this setting to OS2 if the system is running the OS/2 operating system. Note that this operating system is not supported by

Acromag.

Full Screen LOGO Show [Enabled]

This item, if enabled, displays the full screen logo at power-up.

Summary Screen Show [Enabled]

This item, if enabled, displays the BIOS test summary screen at powerup.

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

I/O SERVER User’s Manual Industrial PC

___________________________________________________________________

19

This sub-menu contains advanced system options. Only video settings may be changed here. DO NOT MODIFY ANY OTHER SETTINGS.

Advanced Chipset

Features

WARNING: Changes to the

Advanced Chipset Features sub menu will make the system unstable or inoperable.

Only the VGA Settings can be modified by the user. DO NOT MODIFY

ANY OF THE PRECEDING SETTINGS.

On-Chip Frame Buffer Size [8MB]

This item allows the user to adjust the size of the on-chip graphics of memory buffer. Selections are 1MB or 8MB.

DVMT Mode [DVMT]

This item allows the user to enable

Intel’s Dynamic Video Memory

Technology (DVMT) support on the graphics chipset. Selections are

DVMT, FIXED, and Both. DVMT allows for the operating system to dynamically allocated memory to either the video or system as necessary.

DVMT/FIXED Memory Size [128MB]

This item allows the user to adjust the DVMT/FIXED graphics memory size.

Boot Display [CRT]

This item selects the display type and should always be set to CRT.

Panel Type [ 800 x 600, 18bits]

This item is not supported on the I/O Server.

LCD BackLight [High Active]

This item is not supported on the I/O Server.

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

20

I/O SERVER User’s Manual Industrial PC

__________________________________________________________________

Integrated Peripherals

This menu controls advanced settings for the CompactFlash

®

/Optional

2.5” Drive, USB ports, serial ports, and LAN.

OnChip IDE Device

This item enables users to set IDE Device options for PIO and DMA access modes.

Onboard Device

This item enables users to enable/disable the LAN.

Super IO Device

This item enables users to set the COM port options.

USB Device Setting

This item enables users to set the USB options.

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

I/O SERVER User’s Manual Industrial PC

___________________________________________________________________

21

The OnChip IDE Device allows changes to the CompactFlash optional 2.5” drive settings. Note that the CompactFlash

®

®

and

is the IDE

Primary Mas ter and the 2.5” drive is the IDE Primary Slave. No IDE

Secondary or SATA ports are available on the IOS-7400.

OnChip IDE Device

IDE HDD Block Mode [Enabled]

This item allows the user to enable block mode for both the

CompactFlash

® and/or the 2.5” Drive.

IDE DMA transfer access [Enabled]

This item allows the user to enable DMA access on the

CompactFlash

®

and/or the 2.

5” Drive.

On-Chip Primary PCI IDE [Enabled]

This item must be enabled.

IDE HDD Primary Master/Slave PIO/UDMA [ Auto]

This item allows the user to set PIO/UDMA mode for CompactFlash

® and the 2.5” Drive. Please note that not all CompactFlash

®

or Hard

Drives will support these options.

On-Chip Secondary PCI IDE/ IDE Secondary Master/Slave

PIO/UDMA

These items are not used on the IOS-7400.

On-Chip Serial ATA /Speed Settings/ IDE MODE

These options are not used on the IOS-7400.

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

22

I/O SERVER User’s Manual Industrial PC

__________________________________________________________________

Onboard Device

The Onboard Device menu only allows for control of the onboard LAN controller. Note that disabling this device only disables the connection between the processor and the internal Ethernet switch located in the IOS-

7400. The two external Ethernet ports will still operate as a switch with external connections. Refer to Section 4.0 System Overview for more information on Ethernet operation.

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

I/O SERVER User’s Manual Industrial PC

___________________________________________________________________

23

SuperIO Device

The SuperIO Device page allows changes to the COM ports.

Onboard Serial Port 1/2

This item allows the user to adjust COM port 1 & 2 address and IRQ.

Note that these changes only affect the two external COM ports located on the IOS-7400. IOS modules that support serial connections will not be changed.

UART Mode Select [Normal]

This item allows the user to adjust serial port UART mode. Currently the IOS-7400 only supports Normal mode.

RxD/TxD /IR/ UR2 / Parallel/ EPP/ ECP

These settings are not supported by the IOS-7400.

PWRON After PWR-Fail [Off]

This option is not supported by the IOS-7400.

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

24

I/O SERVER User’s Manual Industrial PC

__________________________________________________________________

USB Device Settings

This menu allows control of USB devices. This includes speed, keyboard, mouse, and storage functionality.

USB 1.0 Controller [ Enabled]

This item allows the user to enable/disable USB 1.0 Controller.

USB 2.0 Controller [Enabled]

This item allows the user to enable/disable USB 2.0 Controller.

USB Operation Mode [High Speed]

This item allows the user to adjust USB devices to operate at either

High (USB 2.0) or Full/Low (USB 1.1/1.0) speed.

USB Keyboard Function [Enabled]

This item allows the user to enable/disable support for USB keyboards.

USB Mouse Function [Enabled]

This item allows the user to enable/disable support for USB mouse.

USB Storage Function [Enabled]

This item allows the user to enable/disable support of USB Mass

Storage devices. This includes external hard drives or flash drives.

USB Mass Storage Device Boot Setting

This item lists USB Mass Storage devices connected and allows the user to set the type of device that is attached. This is required only if the manufacturer of the device fails to include the information within the USB device itself

.

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

I/O SERVER User’s Manual Industrial PC

___________________________________________________________________

25

The Power Management Screen controls advanced power saving techniques. Please note that the majority of these items are not supported by the IOS-7400. Acromag recommends that the power savings options provided in the desired operating system (Windows/Linux) be used in place of BIOS settings. The picture below is shown for reference only.

Power Management

Setup

The PnP/PCI Configuration page controls the DMA and IRQ settings for the system. These items should not be modified. The screen shot is shown for reference purposes only.

PnP/PCI Configurations

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

26

I/O SERVER User’s Manual Industrial PC

__________________________________________________________________

PC Health Status

The PC Health Status screen allows users to enable/disable automatic temperature shutdown. It also displays temperature and voltage information from the processor.

Frequency/Voltage

Control

The Frequency/Voltage Control screen allows changes to the CPU clock and PCI clock settings. These items are set to the optimized defaults and changes are not recommended. This menu is shown for reference only.

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

I/O SERVER User’s Manual Industrial PC

___________________________________________________________________

27

If any errors are made when entering settings in the system BIOS, the system may become unstable or inoperable. Should this occur follow the following procedure to restore the default BIOS settings. Note that this procedure only requires that a keyboard is attached to the IOS-7400. No monitor, bootable drive, or mouse is required.

Bios Recovery Procedure

1. Reset the system by cycling the DC power input.

2. Immediately after turning on power, hit the DEL key for about 15 seconds to enter Setup.

3. Press the Right Arrow key.

4. Press the Down Arrow key.

5. Press the Down Arrow key.

6. Press ENTER.

7. Press the Y key.

8. Press ENTER.

9. Press F10.

10. Press the Y key.

11. Press ENTER.

BIOS Recovery Procedure

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

28

I/O SERVER User’s Manual Industrial PC

__________________________________________________________________

4.0 SYSTEM

OVERVIEW

This Section provides information regarding system design and operating information for the I/O Server. Reference the block diagram below as you read this material.

The I/O Server has an embedded Intel N270 1.6GHz CPU. Intel

WARNING: Per specifications, only the USB ports are switchable while power is applied to the system.

I/O Server Internal Ethernet

Switch

chipsets 946GSE and ICH7M are used for I/O and memory interfaces. The board supports up to 1GB of 533/667MHz DDR2 in a SODIMM socket.

The I/O Server has an integrated graphics engine Intel GMA950 with support for Microsoft DirectX 9.1 Additional interfaces include VGA, AC97 audio, 10/100 LAN, PCI Bus, Primary IDE Bus, four USB Ports, two Serial ports. Support circuitry is provided for all of these interfaces. None of the

I/O Connectors on the I/O Server are isolated (i.e. connector and power logic commons have a direct electrical connection).

The I/O Server has an internal 10/100 “unmanaged” Ethernet Switch.

This switch is designed to work automatically right out of the box with no special programming or setup. The standard settings for the switch are described in the table below. This is a three port switch. One port is connected to the processor unit. The operating system of the I/O Server will always detect a minimal connection to an Ethernet port. The remaining two ports are connected to the external RJ45 jacks on the Front Panel of the I/O Server. Due to this internal switch, the bandwidth from the I/O

Server processing unit to the Field is the same as a single Ethernet port.

I/O Server Power Supply

Fuse

IDE (PATA)

– Hard Drive

Connections

BASIC (DEFAULT) DEVICE OPERATION

Automatic MDI/MDI-X.

Automatic Polarity.

Automatic Half/Full Duplex.

Automatic 10M/100M.

Automatic Address Learning.

Automatic Address Migration.

Automatic Address Aging using 5 minute period (300±75s).

Flow Controls Enabled.

Half-Duplex Back Pressure Applies.

Standard Half-Duplex Back-Off Applies.

Switch will check that frame length conforms to maximum size limit.

Yellow LED indicate Speed 100M ON/10M OFF

Green LED indicate Link ON/Activity Blinking

The 9V to 32V DC supply lines to the I/O server is fused with a current limit of 10 Amps. The fuse is a standard 3AG size. A blown fuse can be identified by non-functional power status LED. The fuse on the motherboard is not easily accessible. An external fuse or current limiting power supplied is recommended.

Acromag’s PS5R-S line of isolated

AC/DC power supplies work well for this application. Contact Acromag for further information.

The Primary IDE (or PATA) hard drive interface along with power is

® physically routed on the PCB boards to both the CompactFlash and optional 2.5” drive. This approach removes any internal cables and the inherent disadvantages associated with them such as lower shock and vibration tolerance. The CompactFlash

®

slot is hard-wired as the Primary

IDE Master. Therefore to prevent contention the optional

2.5” drive must always be set as a Slave (via jumpers) prior to installation. To prevent

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

I/O SERVER User’s Manual Industrial PC

___________________________________________________________________

29 degradation of the I/O Server environmental specifications, Acromag recommends use of a

Solid State (Flash) 2.5” Hard drive. These drives are available from manufacturers such as Transcend or SanDisk and have no mechanical parts. Consequently they have superior shock and vibration and temperature specifications when compared to conventional hard drives.

There are two types of flash available on the market: multi-level cell

(MLC) and single level cell (SLC). MLC Flash is available in higher densities and at a lower cost. However, it comes at a cost of read/write access speed, and low endurance. Endurance for a Flash drive is defined as the number of write cycles to a bit before the bit may loose its charge causing a bit error. SLC flash, while in lower densities at a higher cost, is faster. Additionally it has a far greater endurance (x10) and operates over the extended temperature range. New technology and assorted benchmark tests from vendors have blurred the lines of read and write speed advantages. However, with the greater endurance and larger temperature range, SLC flash is geared towards the embedded market.

Acromag supplies an 8GB SLC CompactFlash

®

card with the IOS-7400-

WIN model.

The carrier board is a PCI bus slave/target board providing support for up to four IOS modules

. The carrier board’s PCI bus interface allows the

IOS-7400 to control and communicate with IOS modules that are present on the IOS Carrier. IOS module field I/O connections link through to the field I/O SCSI2 50 pin connectors. Instructions for removing the IOS

Carrier board and installing IOS modules are provided in Section 2.0 of this manual.

The PCI bus interface is implemented in the logic of the carrier board’s

PCI bus target interface chip. The PCI bus interface chip implements PCI specification version 2.2 as an interrupting slave including 8-bit and 16-bit data transfers to the IOS modules. 32-bit IOS data transfers will be treated as two 16-bit data transfers.

The carrier board registers are implemented in the logic of the carrier board’s FPGA. An outline of the functions provided by the carrier board registers includes:

Identifying if memory space is enabled in the Carrier Identification

Bits.

Selecting either an 8MHz or 32MHz clock for each IOS module in the

Clock Control Register.

Monitoring the error signal received from each IOS module is possible via the IOS Error Bit.

Enabling of PCI bus interrupt requests from each IOS module is possible via the IOS Module Interrupt Enable Bit.

Enabling of interrupt generation upon an IOS module access time out is implemented via the Time Out Interrupt Enable Bit.

Monitoring an IOS module access time out is possible via the IOS

Module Access Time Out Status Bit.

Identify pending interrupts via the carrier’s IOS Module Interrupt

Pending Bit.

Lastly, pending interrupts can be individually monitored via the IOS

Module Interrupt Pending Register.

MLC vs. SLC Flash

The 8GB CompactFlash

®

shipped with the

IOS-7400-WIN uses SLC

Flash.

CARRIER BOARD

OVERVIEW

PCI Bus Interface

Note that the IOS carrier board is not hot-swappable

IOS Carrier Board Registers

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

30

I/O SERVER User’s Manual Industrial PC

__________________________________________________________________

IOS Logic Interface

IOS Carrier Board Clock

Circuitry

PCI Interrupts

IOS Modules Power-On

Reset

IOS Modules Power Supply

Fuses

The IOS logic interface is also implemented in the carrier board’s

FPGA. The PCI bus address and data lines are linked to the address and data of the IOS logic interface.

The PCI bus to IOS logic interface link allows a PCI bus master to:

Access up to 64 ID Space bytes for IOS module identification via 8-bit or 16-bit data transfers using the PCI bus.

Access up to 128 I/O Space bytes of IOS data via 8-bit or 16-bit data transfers.

Access up to 8M Bytes of Memory Space data via 8-bit or 16-bit data transfers.

Access IOS module interrupt space via 8-bit or 16-bit PCI bus data transfers.

Respond up to two interrupt requests per IOS module.

Each IOS module can be individually controlled with either an 8MHz or

32MHz clock. Refer to the IOS modules

User’s Manual to determine clock speed support.

Interrupts may be initiated from an IOS module. However, the carrier board will only pass an interrupt generated by an IOS module to the PCI bus if the carrier board has been first enabled for interrupts. Each IOS module can initiate two interrupts which can be individually monitored on the carrier board. After interrupts are enabled on the carrier board via the

Interrupt Enable Bits, an IOS module generated interrupt is recognized by the carrier board and is recorded in the carrier board’s Interrupt Pending

Register.

A carrier board pending interrupt will cause the board to pass the interrupt to the PCI bus provided the Interrupt Enable bit of the carrier’s

Status Register has been enabled. The PCI interrupt request line assigned by the system will then be asserted. The I/O Server will respond to the asserted interrupt line by executing the interrupt service routine corresponding to the interrupt line asserted.

The carrier board will provide an asynchronous reset signal to all IOS modules for at least 200ms following power-up.

The +5V supply line to each of the IOS modules are individually fused with a current limit of, at minimum, 2 amps imposed by the fuses. In addition, the +12V, and -12V supply lines to each of the IOS modules are individually fused with a current limit of, at minimum, 1 amp imposed by the fuses. A blown fuse can be identified by visible inspection or by use of an ohm meter. The fuses can be located via the IOS Fuse Location Drawing found in the Appendix of this manual. Note that fuse type and current limit may vary. Contact Acromag for further details.

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

I/O SERVER User’s Manual Industrial PC

___________________________________________________________________

31

The IOS Carrier and subsequently the IOS modules must be accessed thought the PCI bus. The PCI bus is defined to address three distinct address spaces: I/O, memory, and configuration space. The IOS modules

can be accessed via the PCI bus memory space only.

The IOS carrier is a Plug-and-Play PCI board. As a Plug-and-Play card the IOS Carrier board’s base address and system interrupt request line are assigned by system software upon power-up via the configuration registers. A PCI bus configuration access is used to access a PCI card’s configuration registers.

When the computer is first poweredup, the computer’s system configuration software scans the PCI bus to determine what PCI devices are present. The software also determines the configuration requirements of the PCI card.

The system software accesses the configuration registers to determine how many blocks of memory space the carrier board requires. It then programs the carrier board’s configuration registers with the unique memory address range assigned.

The configuration registers are also used to indicate that the IOS carrier board requires an interrupt request line. The system software then programs the configuration registers with the interrupt request line assigned to the IOS carrier.

The PCI bus is designed to recognize certain I/O accesses initiated by the host processor as a configuration access. Configuration uses two 32bit I/O ports located at addresses 0CF8 and 0CFC hex. These two ports are:

32-bit configuration address port, occupying I/O addresses 0CF8 through 0CFB hex.

32-bit configuration data port, occupying I/O addresses 0CFC through

0CFF hex.

Configuration space, shown in Table 5.1, is accessed by writing a 32-bit long-word into the configuration address port that specifies the PCI bus, the carrier board on the bus, and the configuration register on the carrier board being accessed. A read or write to the configuration data port will then cause the configuration address value to be translated to the requested configuration cycle on the PCI bus. Accesses to the configuration data port determine the size of the access to the configuration register addressed and can be either an 8, 16, or 32-bit operation.

Any access to the Configuration address port that is not a 32-bit access is treated like a normal computer I/O access. Thus, computer I/O devices using 8 or 16-bit registers are not affected because they will be accessed as expected.

The PCI specification requires software driven initialization and configuration via the Configuration Address space. This PCI carrier board provides 256 bytes of configuration registers for this purpose. The PCI carrier board contains the configuration registers, shown in Table 5.2, to facilitate Plug-and-Play compatibility.

5.0 ACCESSING THE

IOS CARRIER

PCI Configuration Address

Space

PCI Configuration

Transactions

PCI Configuration Registers

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

32

I/O SERVER User’s Manual Industrial PC

__________________________________________________________________

Table 5.1: Configuration

Address Port

Table 5.2: Configuration

Registers

MEMORY MAP

6

7

8:10

11

12

13

14

15

Reg.

Num.

0

1

2

3

4

5

The Configuration Registers are accessed via the Configuration

Address and Data Ports. The most important Configuration Registers are the Base Address Registers and the Interrupt Line Register, which must be read to determine the base address, assigned to the carrier board and the interrupt request line that goes active on a carrier interrupt request.

BIT FUNCTION

31 Enables accesses to Configuration Data to be translated to configuration cycles on the PCI bus.

30-24 Reserved, Return 0 when read.

23-16 Bus Number

Choose a specific PCI bus in the system. Zero if only one item on the PCI bus.

15-11 Device Number

Choose a specific device/PCI board on the bus.

10-8 Function Number

Choose a specific function in a device. Function number is zero for the IOS carrier.

7-2

1-0

Register Number

Used to indicate which PCI Configuration Register to access. The Configuration Registers and their corresponding register numbers are given in Table 3.2.

Read Only bits that return 0.

D31

D24

D23 D16 D15 D8 D7 D0

Device ID=1024

Status

BIST Header Latency Cache

Base Addr. Memory Mapped Configuration Registers

Base Address for I/O Mapped Configuration Registers

PCIBar2: Base Address for Carrier/IO/ID/INT Space

PCIBar3: Base Address for Memory Space

Subsystem ID

Max_Lat

Class Code

Vendor ID= 10B5

Command

Rev ID

Not Used

Subsystem Vendor ID

Not Used

Min_Gnt

Reserved

Reserved

Inter. Pin Inter. Line

This carrier board consumes a 1K byte block and a 64M byte block of memory. The 1K byte block of memory consumed by the board is composed of blocks of memory for the ID, I/O and INT spaces corresponding to four IOS modules. In addition, a small portion of the 1K byte address space contains registers specific to the function of the IOS carrier board. The 64M byte block of memory is composed of the Memory

Space for up to four IOS modules.

The carrier board is configured to map this 1K byte and 64M byte block of memory into 32-bit memory space. The system configuration software will allocate space by writing the assigned addresses into the corresponding Base Address registers of the Configuration Registers. The memory map for IOS Carrier board is shown in Tables 5.3.

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

I/O SERVER User’s Manual Industrial PC

___________________________________________________________________

33

0141

017F

0181

01FF

0201

027F

0281

02FF

0301

037F

0381

03FF

PCIBar2

+

(Hex)

0001

0003

0005

0007

0009

000B

000D

High Byte

D15 D08

Low Byte

D07 D00

Carrier Board Status / Control Register

IOS Interrupt Pending Register

IOS A Interrupt 0 Select Space

IOS A Interrupt 1 Select Space

IOS B Interrupt 0 Select Space

IOS B Interrupt 1 Select Space

IOS C Interrupt 0 Select Space

IOS C Interrupt 1 Select Space

000F

0011

0013

0015

0017

0019

001B

003F

0041

007F

0081

00BF

00C1

00FF

0101

013F

IOS D Interrupt 0 Select Space

IOS D Interrupt 1 Select Space

Clock Control Register

Not Used

IOS A

IOS B

IOS C

IOS D

1

ID Space

ID Space

ID Space

ID Space

Not Used

1

Not Used

1

Not Used

1

IOS A

ID Space

IOS B

ID Space

IOS C

ID Space

IOS D

ID Space

Not Used

IOS A

Not Used

1

I/O Space

IOS B

I/O Space

IOS C

I/O Space

IOS D

I/O Space

1

Not Used

IOS A

I/O Space

IOS B

I/O Space

IOS C

I/O Space

IOS D

I/O Space

Not Used

1

1

PCIBar2

+

(Hex)

0000

0002

0004

0006

0008

000A

000C

000E

0010

0012

0014

0016

0018

001A

003E

0040

007E

0080

00BE

00C0

00FE

0100

013E

0140

017E

0180

01FE

0200

027E

0280

02FE

0300

037E

0380

03FE

Table 5.3: IOS Carrier Board

Memory Map

1. The board will return “0” for all addresses that are not used.

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

34

I/O SERVER User’s Manual Industrial PC

__________________________________________________________________

Table 5.3: IOS Carrier Board

Memory Map Continued

Carrier Status/Control

Register - (Read/Write,

PCIBar2 + 00H)

PCIBar3

+

(Hex)

0000001

07FFFFF

0800001

0FFFFFF

1000001

17FFFFF

High Byte

D15 D08

IOS A

D07 D00

Memory Space

IOS B

Memory Space

IOS C

Memory Space

Low Byte PCIBar3

+

(Hex)

0000000

07FFFFE

0800000

0FFFFFE

1000000

17FFFFE

1800001

1FFFFFF

IOS D

Memory Space

1800000

1FFFFFE

2000001

Not Used

2000000

3FFFFFF 3FFFFFE

1. The board will return “0” for all addresses that are not used.

The IOS carrier board’s base addresses are determined through the

PCI Configuration Registers. The addresses given in the memory map are relative to the base addresses (PCIBar2, PCIBar3) of the IOS Carrier as shown in Table 5.2. The addresses within each IOS module are specific to that IOS module. Refer to the IOS module’s User Manual for information relating to the IOS specific addressing.

The Carrier registers, IOS Identification (ID) spaces, IOS Input/Output

(IO), IOS Interrupt spaces, and Memory (MEM) spaces are accessible via the PCI bus space as given in Tables 5.3. A 32-bit PCI bus access will result in two 16-bit accesses to the IOS module. A 16-bit or 8-bit PCI bus access results in a single 16-bit or 8-bit access to the IOS module respectively.

The Carrier Board Status Register reflects and controls functions globally on the carrier board. This includes monitoring the IOS Error signal, enabling, disabling, or monitoring IOS and timeout interrupts, performing a software reset for the carrier board and IOS modules, and identifying if memory space is enabled.

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

I/O SERVER User’s Manual Industrial PC

___________________________________________________________________

35

BIT FUNCTION

15-12 Carrier Identification:

These bits are used for carrier identification. Writing to these bits will result in the data being stored. Reading these bits will result in the inverse of the stored value. Reset

Condition: “1011”.

11-09

Not Used (bits read as logic “0”)

08

Write

Only

Software Reset

Writing a “1” to this bit causes a software reset. Writing a

“0” or reading this bit has no effect. When set, the software reset pulse will have a duration of 1

 s (microsecond).

07-06

Not Used (bits read as logic “0”)

05

Read

IOS Module Access Time Out Interrupt Pending

This bit will be "1" when there is an IOS Module Access

And

Write

Time Out interrupt pending. This bit will be "0" when there is no interrupt pending. Reset condition: Set to "0". Writing a “1” to this bit will release the pending interrupt.

04

Read

Only

03

Read

And

Write

02

Read

And

Write

IOS Module Access Time Out Status

Status bit to indicate that the last IOS module access has timed out. This bit only reflects the last IOS module access.

“0” if last IOS module access did not time out.

“1” if last IOS module access did time out.

Time Out Interrupt Enable

When set to “1”, this bit will enable the carrier board to generate an interrupt upon time out of an IOS module access. The default setting or reset condition is “0”

(interrupt generation upon time out disabled). The interrupt service routine, in responding to the Time Out Access interrupt, will need to set this bit to 0 to clear the pending interrupt request.

IOS Module Interrupt Enable

When set to “1”, this bit will enable the generation of IOS module interrupts. The default setting or reset condition is

“0” (IOS module interrupt generation disabled). Interrupts must also be supported and configured on the IOS module.

01

Read

Only

00

Read

Only

IOS Module Interrupt Pending

This bit will be "1" when there is an interrupt pending. This bit will be "0" when there is no interrupt pending. Polling this bit will reflect the IOS

Module’s pending interrupt status, even if the IOS Module Interrupt Enable bit is set to

"0". Reset condition: Set to "0".

IOS Module Error

This bit will be "1" when there is an active IOS Module

Error signal. This bit will be "0" when all IOS module Error signals are inactive. This bit allows the user to monitor the

Error signals of IOS modules A through D. Refer to your

IOS module specific documentation to see if the error signal is supported and what it indicates. Reset condition:

Set to "0".

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

36

I/O SERVER User’s Manual Industrial PC

__________________________________________________________________

IOS Interrupt Pending

Register - (Read, PCIBar2 +

02H)

Clock Control Register -

(Read/Write, PCIBar2 +

018H)

IOS Module Interrupt Space

- (Read Only)

The IOS Interrupt Pending Register is used to individually identify pending IOS module interrupts or a pending carrier board generated interrupt as a result of IOS module time out access. If multiple IOS module interrupts are pending, software must determine the order in which they are serviced.

MSB

D7

IOS D

Int1

Pend

D6

IOS D

Int0

Pend

D5

IOS C

Int1

Pend

D4

IOS C

Int0

Pend

D3

IOS B

Int1

Pend

D2

IOS B

Int0

Pend

D1

IOS A

Int1

Pend

LSB

D0

IOS A

Int0

Pend

MSB

D15 D14

Not Used

(bits read as logic “0”)

D13 D12

Time Out

Interrupt

Pend

D11 D10

Not Used (bits

D9

LSB

D8

read as logic “0”)

All Bits

IOS Interrupt

Pending

(Read)

A bit will be a “1” when the corresponding interrupt is pending. A bit will be a “0” when its corresponding interrupt is not pending. Polling this bit will reflect the

IOS module’s pending interrupt status, even if the IOS modules interrupt enable bit is set to “0”.

Reset Condition: Set to "0". An IOS module pending interrupt bit will be cleared if its corresponding interrupt request signal is inactive.

The Clock Control Register is used to select the operational frequency of individual IOS modules. A “0” (default) indicates that the IOS module is supplied with an 8MHz clock. A “1” indicates that the IOS module is supplied a 32MHz clock

. A reset will set all bits of this register to “0”.

MSB

D15 D4

Not Used

D3

IOS D

CLK

D2

IOS C

CLK

D1

IOS B

CLK

LSB

D0

IOS A

CLK

The Interrupt space for each IOS module is fixed at two 16-bit words.

Interrupt 0 select space is read, typically by an interrupt service routine, to respond to an interrupt request via the IOS

Module’s INTREQ0* signal.

Likewise interrupt 1 select space is read to respond to an interrupt request via the IOS

Module’s INTREQ1* signal. An access to an interrupt select space results in the IOS module serving up an interrupt vector. In addition, access to the interrupt space will cause some IOS modules to release their interrupt request. See each IOS module’s User Manual for details.

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

I/O SERVER User’s Manual Industrial PC

___________________________________________________________________

37

Each IOS module contains identification (ID) information that resides in the ID space. This area of memory contains at most 64 bytes of information. Both fixed and variable information may be present within the

ID ROM. Variable information may include unique information required for the IOS module. The identification Section for each IOS module is located in the carrier board memory map per Table 5.3. Refer to the documentation of the specific IOS module for information about ID Space contents.

The I/O space on each IOS module is fixed at 128, 16-bit words (256 bytes). The four IOS module I/O spaces are accessible at fixed offsets from PCIBar2. IOS modules may not fully decode their I/O space and may use byte or word only accesses. See each IOS module’s User Manual for details.

Each IOS module may contain up to 8M bytes of Memory Space arranged into 16-bit words. The four IOS module Memory spaces are accessible at fixed offset from PCIBar3. IOS modules may not fully decode their Memory space and may use only byte or word accesses. See each

IOS module’s User Manual for details.

Interrupt requests originate from the carrier board in the case of an access time out and from the IOS modules. Each IOS may support 0, 1, or

2 interrupt requests. Upon an IOS module interrupt request, the carrier board passes the interrupt request on to the processor unit, provided that the carrier board is enabled for interrupts within the Carrier Board Status

Register.

1. Clear the interrupt enable bits in the Carrier Board Status Register by writing a "0" to bit 2/bit 3.

2. Write an Interrupt Service Routine appropriate for your application and perform any other IOS specific configuration required.

3. Determine the IRQ line assigned to the carrier during system configuration (within the configuration register).

4. The IOS module asserts an interrupt request to the carrier board

(asserts interrupt request line IntReq0* or IntReq1*).

5. The carrier board drives PCI bus interrupt request signal INTA# active.

6. The interrupt service routine starts. Refer to the software documentation for connecting the ISR to the IOS module Interrupts.

7. Interrupt service routine determines which IOS module caused the interrupt by reading the carrier board interrupt pending register. If multiple interrupts are pending, the interrupt service routine software determines which IOS module to service first.

8. Perform desired IOS module operations in the ISR and re-enable interrupts.

IOS Module ID Space- (Read

Only)

IOS Module I/O Space -

(Read/Write)

IOS Module Memory Space -

(Read/Write)

GENERATING

INTERRUPTS

Sequence of Events for an

Interrupt

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

38

I/O SERVER User’s Manual Industrial PC

__________________________________________________________________

6.0 SERVICE AND

REPAIR

SERVICE AND REPAIR

ASSISTANCE

PRELIMINARY

SERVICE PROCEDURE

CAUTION: POWER MUST

BE TURNED OFF

BEFORE REMOVING OR

INSERTING BOARDS

WHERE TO GET HELP www.acromag.com

Surface-Mounted Technology (SMT) boards are generally difficult to repair. It is highly recommended that a non-functioning board be returned to Acromag for repair. The board can be easily damaged unless special

SMT repair and service tools are used. Further, Acromag has automated test equipment that thoroughly checks the performance of each board.

When a board is first produced and when any repair is made, it is tested, placed in a burn-in room at elevated temperature, and retested before shipment.

Please refer to Acromag's Service Policy Bulletin or contact Acromag for complete details on how to obtain parts and repair.

Before beginning repair, be sure that all of the procedures in Section 2,

Preparation For Use, have been followed. Also, refer to the documentation of your carrier/CPU board to verify that it is correctly configured.

Replacement of the board with one that is known to work correctly is a good technique to isolate a faulty board.

If you continue to have problems, your next step should be to visit the

Acromag worldwide web site at http://www.acromag.com

. Our web site contains the most up-to-date product and software information.

Choose the “Support” hyperlink in our website’s top navigation row or look for product specific information by searching for the specific model under question using the search box:

An email question can be submitted through the “Contact Us” hyperlink at the top of any web page.

Acromag’s application engineers can also be contacted directly for technical assistance via telephone or FAX through the numbers listed at the bottom of this page. When needed, complete repair services are also available.

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

I/O SERVER User’s Manual Industrial PC

___________________________________________________________________

39

Single IOS-7400

Depth

Width

Length

76.2 mm (3.0 in)

182.9 mm (7.3 in)

299.7 mm (11.8 in)

IOS-7400: 6.00lbs (2.72Kg) No IOS modules included.

Shipping Weight: TBD

CPU: Embedded Intel

®

ATOM N270 1.6 GHz processor

Front Side Bus: 533 MHz FSB

System Chipset: Intel 945GSE/ ICH7M

BIOS: AWARD

Technology: DDR2 400/533 MHz

Capacity: 1 GB

Form Factor: 1 x 200-pin SODIMM socket

Chipset: Intel 845GSE

Power: +5V (pin 9) 500mA Max (internally fused)

Resolution: Supports up to 2048 x 1536

Connector: VGA 9 Pin

Housing: Polyester Glass Filled

Metal Shell: Steel

Plating: Gold Flash

Chipset: Intel 82562GZ

Internal Unmanaged switch: Micrel KS8995

Connector: Five shielded RJ-45 sockets, 8-pin, 10BaseT/100BaseTX.

Wiring: Ports are wired MDI-X and include automatic MDI-X/MDI crossover.

Data Rate: Auto-negotiated, 10Mbps or 100Mbps.

Compliance: IEEE 802.3, 802.3u, 802.3x.

Duplex: Auto-negotiated, Full or Half Duplex.

Port Status Indicators:

Two LED’s per port – Yellow and green.

Yellow indicates speed, and green indicates link status and activity.

Maximum Message Length/Frame Size: 1536 bytes.

Illegal Frame Detection: Frames less than 64 bytes and more than maximum are discarded.

Flow Control: IEEE 802.3x flow control on both transmit an receive is enabled.

Half-Duplex Back Pressure (Non IEEE 802.3 standard): Uses carrier sense deference during heavy traffic to unburden resources.

Half-Duplex Backoff: Binary exponential per IEEE 802.3.

Address Learning: Automatic, storage of up to 1K (1024) MAC addresses.

Address Aging: Automatic, enabled for 5 minutes.

Address Migration: Automatic.

Frame Retry w/Collision: Will drop frame after 16 collisions.

Late Collision Detection: Transmit packet is dropped if collision occurs after 512 bit times of transmission. Late collisions are usually indicative of illegal cable length.

7.0

SPECIFICATIONS

PHYSICAL

Unit Weight (Including all mounting hardware)

ELECTRICAL

Processor

Memory

Display

Ethernet

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

40

I/O SERVER User’s Manual Industrial PC

__________________________________________________________________

USB

Audio

Serial

IOS Carrier

Connector: Four shielded USB Type A sockets, 4-pin

Housing: High Temperature Thermoplastic

Metal Shell: Copper Alloy

Plating: Gold Flash

Compliance: USB 2.0.

Current Limit: 500mA Maximum each port

Over Current Disable: Port automatically disabled if current draw is greater than 600mA.

Insertion Cycles: 1500 minimum

Retention: Ports 1 & 2 15N minimum (Class 1, DIV II)

Chipset: Realtek ALC203 AC97 Codec

Power Output: 250mW at 8

Ω load typical.

Total Harmonic Distortion+Noise: THD+N at 1kHz at 200mW continuous average output power into 8Ω: 0.5% (max)

Connector: 3.5mm Stereo Jack

Housing: PBT

Metal Shell: Brass

Plating: Tin

Contact Resistance: 50m

Ω Maximum

Insertion Cycles: 5000 minimum

Microphone: Mono Input

Audio Out: Stereo Output (2 channels)

Connector: Two shielded male DB9 Com Ports.

Housing: Polyester Glass Filled

Metal Shell: SPCC

Plating: Gold Flash

Compliance: Compatible with EIA/TIA-232F communications standard.

Maximum Cable Length: 15M (50 feet) typical, limited to a cable capacitive load of 2500pF.

DRIVERS:

Output Voltage Swing................±5.4V Typical, ±5V Minimum

(Loaded with 3K

Ω to ground).

Output Short Circuit Current.....±60mA Max.

Output Resistance....................300

Ω Minimum. 10MΩ Typical

Output Slew Rate (+3 to -3V)....6V/us Min to 30V/us Max (CL =150-

1000pF, RL = 3K

Ω to 7KΩ).

Output Leakage Current: ±25uA Max

RECEIVERS:

Data Rate.......................................Up to 250 Kbps.

Input Voltage Range......................±25V DC Maximum.

Input High Threshold.....................1.8V Minimum, 2.4V Maximum.

Input Low Threshold......................0.8V Minimum, 1.5V Maximum.

Input Resistance............................3K

Ω to 7KΩ.

Input Hysteresis.............................0.5V

IOS Carrier Module: Holds Four Acromag IOS modules.

Insertion Cycles: Recommend users do not exceed 30 insertion cycles.

Connectors: Four 50-pin female SCSI-2 on front panel.

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

I/O SERVER User’s Manual Industrial PC

___________________________________________________________________

41

IOS Slot Fuses (Replacement part number):

+5 Volts………………………….. 4 Amps (Littlefuse/R429004)

+12 Volts………………………… 3 Amps (Littlefuse/R429003)

-

12 Volts…………………………. 3 Amps (Littlefuse/R429003)

Note: These fuses are rated higher than needed to handle the in-rush currents and avoid nuisance fuse replacements.

Form Factor: Type I/II CompactFlash

®

50 pin Card. Socket has left side ejector.

IOS-7400-WIN: This models ships with an 8GB Industrial SLC

CompactFlash

®

.

Temp: -40

C to 85

C

MTBF: > 4,000,000 hours

Power Requirements: 9-32V DC, 30W Typical, 60W Maximum. Keep DC power cables less than 10m in length. Divide power by your voltage to calculate max current. Then select a supply that can deliver an inrush current of at least twice this amount.

The PS5R-S line Universal AC/DC power supplies sold by Acromag meet the I/O Server power requirements. Specifically the 24V models PS5R-

SD24 (60W) or preferably PS5R-SE24 (90W). The PS5R-SD24 (60W) provides up to 2.5A of current at 24V. The PS5R-SE24 (90W) provides up to 3.75A of current at 24V. Like many modern power supplies, the PS5R-S series have overcurrent features to assist with the large inrush current at power-up and a good dynamic load response to adapt to processes such as heavy processor, USB, or video use that require significant increases in power consumption. Failure to provide at minimum 60W power

supplies and/or inrush capabilities at least twice the input current

(I inrush

=2* V in

/60) can result in device reset or failure. Note that if the external supply falls below 8.2V, then the I/O Server immediately shutdowns to prevent damage to internal components.

IOS-7400

Power Requirements

TYP

1

MAX

2

Processor + 1G DDR

Other Controls I/O

CompactFlash

®

Slot

11.5W

2.12W

0.63W

25W

6W

1.5W

Optional Hard Drive

IOS Modules

1.5W

20W

3

1. Typical Operating conditions at 25

C running test program that exercises all I/O ports.

2. This is the maximum amount of power allotted to each device via the internal supplies.

3. This includes +5V, -12V, and +12V power from all 4 IOS modules.

Certain combinations of IOS modules will exceed the allotted power and may cause overheating. Refer to the individual IOS modules User’s manuals for power usage specifications.

Form Factor:

2.5” Hard Drive

Bus: Parallel EIDE. Not compatible with SATA.

Current: 300mA Maximum

Compliance: ATA-6.

CompactFlash

®

Power

Table 7.1: Power

Requirements.

Optiona l 2.5” Drive

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

42

I/O SERVER User’s Manual Industrial PC

__________________________________________________________________

BIOS Battery Back-up

ENVIRONMENTAL

WARNING: - Explosion

Hazard

– Do not disconnect equipment unless power has been removed or the area is known to be non-hazardous.

WARNING: - The area must

be known to be nonhazardous before servicing

/replacing the unit and before installing.

BIOS Battery: Lithium Coin Cell #BR2032, 3 Volts/190mA, 20mm

Diameter x 3.2mm height.

CAUTION, Battery may explode if mistreated. Do not recharge, disassemble or dispose of in fire.

CAUTION: Risk of Explosion if battery is replaced by an incorrect type.

Dispose of used batteries according to local disposal jurisdiction."

Maximum Surrounding Air Temperature: -30

C to +75

C, T-Code: T3C

Relative Humidity: 5-95% Non-Condensing.

Storage Temperature: -40

C to 85

C.

Non-Isolated: Power and field commons have a direct electrical connection.

Shock & Vibration Immunity: Surface mounted unit with all cables attached except USB Ports 3 and 4

Sinusoidal Vibration: IEC 60068-2-6: 10-500 Hz, 5G, 2 Hours/axis

Random Vibration: IEC 60068-2-64: 10-500 Hz, 5G-rms, 2 Hours/axis

Operating Shock: IEC 60068-2-27:

30g, 11 ms half sine, 18 shocks at 6 orientations

50g, 3ms half sine, 18 shocks at 6 orientations

Agency Approvals: FCC Class A, CE (EMC Directive 2004/108/EC).

Electromagnetic Interference Immunity (EMI): Inputs/outputs have demonstrated resistance to inadvertent state changes with interference from switching solenoids, commutator motors, and drill motors.

Electromagnetic Compatibility (EMC) -

Minimum Immunity per European Norm EN61000-6-2:2001

Electrostatic Discharge (ESD) Immunity: 4KV direct contact and 8KV air-discharge to the enclosure port per IEC61000-4-2.

Radiated Field Immunity (RFI): 10V/M, 80 to 1000MHz AM and

900MHz keyed carrier, per IEC61000-4-3.

Electrical Fast Transient Immunity (EFT): 2KV to power, and 1KV to signal I/O per IEC61000-4-4.

Conducted RF Immunity (CRFI): 10Vrms, 150KHz to 80MHz, per

IEC61000-4-6.

Surge Immunity: 0.5KV to power per IEC61000-4-5. By the standard, this test is not applicable to DC power input ports intended to be permanently connected to cables less than 10m in length. Further, this test is not applicable to I/O ports that interface via cables whose total length is less than 30m.

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

I/O SERVER User’s Manual Industrial PC

___________________________________________________________________

43

Emissions per European Norm EN61000-6-4:2001

Radiated Frequency Emissions: 30 to 1000MHz per CISPR11 Class A

WARNING: This is a Class A product. In a domestic environment, this product may cause radio interference in which the user may be required to take adequate measures.

Mean Time Between Failures: Contact the Factory.

Reliability Prediction

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

44

I/O SERVER User’s Manual Industrial PC

__________________________________________________________________

APPENDIX

IOS-7400 Block

Diagram

Atom N270

1.6GHz

Processor

FSB53

3

945GSE

DDR2

533/667mHzu p to 1GB

Analog RGB

VGA

Connector

Audio 3.5mm

Jack

Microphone

3.5mm jack

A

AC97 Codec

ALC203

USB

(4 ports)

USB

2.0

BIOS

PCI Bus 32bit 33MHz

IOS CARRIER

IOS Modules (x4)

B C D

DMI

ICH7-M

LPC Bus

Super I/O

W83627DHG

COM x2

Serial

Port (x2)

Primary IDE

Compact-

Flash

®

(Master)

LCI

LAN

(82562GZ)

Internal connection

Ethernet switch

KSZ8995

RJ45

Port 1

RJ45

Port 2

2.5” Drive

(Slave)

Field I/O SCSI 50 pin (x4)

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

I/O SERVER User’s Manual Industrial PC

___________________________________________________________________

45

APPENDIX

IOS Carrier Fuse

Location Diagram

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

46

I/O SERVER User’s Manual Industrial PC

__________________________________________________________________

APPENDIX

System I/O Ports

Note that not all listed resources are available for use on the IOS-7400.

ADDR.

RANGE(HEX)

0000 - 0CF7

0000 - 000F

0010 - 001F

0020 - 0021

0022 - 003F

0040 - 0043

0044 - 005F

0060 - 0060

0061 - 0061

0062 - 0063

0064 - 0064

0065 - 006F

0070 - 0073

0074 - 007F

0080 - 0090

0091 - 0093

0094 - 009F

00A0 - 00A1

00A2 - 00BF

00C0 - 00DF

00E0 - 00EF

00F0 - 00FF

01F0 - 01F7

0274 - 0277

0279 - 0279

02F8 - 02FF

0378 - 037F

03B0 - 03BB

03C0 - 03DF

03F6 - 03F6

03F8 - 03FF

04D0 - 04D1

0500 - 051F

0778 - 077B

0880 - 088F

0A78 - 0A7B

0B78 - 0B7B

0BBC - 0BBF

0D00 - FFFF

0E78 - 0E7B

0F78 - 0F7B

0FBC - 0FBF

DEVICE

PCI bus

Direct memory access controller

Motherboard resources

Programmable interrupt controller

Motherboard resources

System timer

Motherboard resources

Standard 101/102-Key or Microsoft Natural PS/2 Keyboard

System speaker

Motherboard resources

Standard 101/102-Key or Microsoft Natural PS/2 Keyboard

Motherboard resources

System CMOS/real time clock

Motherboard resources

Direct memory access controller

Motherboard resources

Direct memory access controller

Programmable interrupt controller

Motherboard resources

Direct memory access controller

Motherboard resources

Numeric data processor

Primary IDE Channel

ISAPNP Read Data Port

ISAPNP Read Data Port

Communications Port (COM2)

Printer Port (LPT1)

Intel Corporation US15 Embedded Graphics

Intel Corporation US15 Embedded Graphics

Primary IDE Channel

Communications Port (COM1)

Motherboard resources

Intel® SCH Family SMBus Controller

Printer Port (LPT1)

Motherboard resources

Motherboard resources

Motherboard resources

Motherboard resources

PCI bus

Motherboard resources

Motherboard resources

Motherboard resources

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

I/O SERVER User’s Manual Industrial PC

___________________________________________________________________

47

D000 - DFFF

DF00 - FF3F

E000 - EFFF

FB00 - FB0F

FC00 - FC1F

FD00 - FD1F

Intel® SCH Family PCI Express Root Port 3 - 8112

Intel® PRO/100 VE Network Connection

Intel® SCH Family PCI Express Root Port 1 - 8110

Standard Dual Channel IDE Controller

Intel® SCH Family USB Universal Host Controller

8116

Intel® SCH Family USB Universal Host Controller

8115

Intel® SCH Family USB Universal Host Controller

8114

Intel® Corporation US15 Embedded Graphics

FE00 - FE1F

FF00 - FF07

Interrupt# Interrupt source

NMI

Parity error detected

IRQ 0

IRQ 1

System timer / High precision event timer

Standard 101/102-Key or Microsoft Natural PS/2

Keyboard

IRQ 2

Available

IRQ 3

Communications Port (COM2)

IRQ 4

Communications Port (COM1)

IRQ 5

Available

IRQ 6

Available

IRQ 7

Available

IRQ 8

System CMOS/real time clock

IRQ 9

Microsoft ACPI-Compliant System

IRQ 10

Available

IRQ 11

Available

IRQ 12

PS/2 Compatible Mouse

IRQ 13

Numeric data processor

IRQ 14

Primary IDE Channel

IRQ 15

Available

IRQ 16

Intel® SCH Family PCI Express Root Port 1 - 8110

Intel® SCH Family USB Universal Host Controller - 8114

Microsoft UAA Bus Driver for High Definition Audio

SDA Standard Compliant SD Host Controller

IRQ 17

Intel® PRO/100 VE Network Connection

Intel® SCH Family PCI Express Root Port 3 - 8112

Intel® SCH Family USB Universal Host Controller - 8115

SDA Standard Compliant SD Host Controller

IRQ 18

Intel® SCH Family USB Universal Host Controller - 8116

SDA Standard Compliant SD Host Controller

IRQ 19 Intel® SCH Family USB2 Enhanced Host Controller -

8117

USB and Ethernet IRQ is automatically set by the system

APPENDIX

System I/O Ports

Note that not all listed resources are available for use on the IOS-7400.

System IRQ

Assignments

Note that not all listed resources are available for use on the IOS-7400.

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

48

I/O SERVER User’s Manual Industrial PC

__________________________________________________________________

APPENDIX

1

st

MB Memory Map

Note that not all listed resources are available for use on the IOS-7400.

Addr. range (Hex)

Device Device

00000000 - 0009FFFF System board

000A0000 - 000BFFFF PCI bus

000A0000 - 000BFFFF Intel Corporation US15 Embedded Graphics

000C0000 - 000DFFFF PCI bus

000E0000 - 000EFFFF PCI bus

000F0000 - 000FFFFF System board

00100000 - 7F6DFFFF System board

7F6E0000 - 7F7FFFFF System board

7F800000 - FEBFFFFF PCI bus

D8000000 - DFFFFFFF Intel Corporation US15 Embedded Graphics

E0000000 - EFFFFFFF Motherboard resources

FDA00000 - FDCFFFFF Intel(R) SCH Family PCI Express Root Port 3

- 8112

FDCC0000 - FDCDFFFF Intel(R) PRO/100 VE Network Connection

FDCFF000 - FDCFFFFF Intel(R) PRO/100 VE Network Connection

FDD00000 - FDEFFFFF Intel(R) SCH Family PCI Express Root Port 1

- 8110

FDF00000 - FDF7FFFF Intel Corporation US15 Embedded Graphics

FDFC0000 - FDFDFFFF Intel Corporation US15 Embedded Graphics

FDFF8000 - FDFFBFFF Microsoft UAA Bus Driver for High Definition

Audio

FDFFC000 - FDFFC0FF SDA Standard Compliant SD Host Controller

FDFFD000 - FDFFD0FF SDA Standard Compliant SD Host Controller

FDFFE000 - FDFFE0FF SDA Standard Compliant SD Host Controller

FDFFF000 - FDFFF3FF Intel(R) SCH Family USB2 Enhanced Host

Controller - 8117

FEC00000 - FEC00FFF System board

FED00000 - FED000FF System board

FED00000 - FED003FF High precision event timer

FED13000 --FED1DFFF System board

FED20000 - FED8FFFF System board

FEE00000 - FEE00FFF System board

FFB00000 - FFB7FFFF System board

FFB80000 - FFBFFFFF Intel(R) 82802 Firmware Hub Device

FFF00000 - FFFFFFFF System board

________________________________________________________________________

Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com

advertisement

Related manuals

advertisement

Table of contents